ALLIANCE weld pins are used in conjunction with ALLIANCE self-locking washers to complete the insulation fastening operation.
|
|
- Beverly Stevens
- 6 years ago
- Views:
Transcription
1
2 ALLIANCE weld pins simplify the permanent attachement of insulation to just about any kind of construction metal surface. They can be applied quickly and easily using standard CD or ARC stud welding equipment. ALLIANCE weld pins are available in several different styles to cover a wide variety of application requirements. Some of the factors to consider concerning the style needed for your application would be the base metal type, size and surface condition, and also the welding equipment to be used. ALLIANCE weld pins are used in conjunction with ALLIANCE self-locking washers to complete the insulation fastening operation. For more information concerning the application of weld pins, see the page 2 APPLICATION in this section. For more information concerning self-locking washers refer to the Washers, Caps and Nuts section, page 16 to 19 of this catalog. 1
3 1. WELD PINS IN PLACE. 2. HANG INSULATION ON PINS. 3. PRESS WASHERS ON PINS TO SECURE INSULATION. 4. EITHER CLIP PINS OFF AT WASHER OR BEND PINS OVER WASHER. FOR MORE INFORMATION, CONSULT YOUR ALLIANCE SALES REPRESENTATIVE. 2
4 HOLE GAUGE Min D Min L Mild Steel / SS-304 FD Aluminum FD 12 GA / GA / APPLICATION: This is standard weld pins used for more application. MATERIAL: Low carbon steel, 304 Stainless Steel, Aluminum PLATING: Copper coating is standard on Mild Steel pins. WASHERS: Self-Locking washers are available in a variety of sizes, shapes, and materials. PROPERTIES: Values for various alloys available upon request. ANNEALING : All Steel pins are fully annealed unless otherwise specified. Length L Std Box QTY Wgt/1000 Mild Steel Wgt/1000 SS-304 Wgt Alum. 3/ / / / / / / / Length L Std Box QTY Wgt/1000 Mild Steel Wgt/1000 SS-304 Wgt Alum / / / / / / Contact your ALLIANCE sales representative for information on sizes, or lengths. 3
5 APPLICATION : This is the standard weld pins used when only ARC stud welding equipment is available. WASHERS : Self-locking washers are available in a variety of sizes, shapes, and materials. FERRULES : Ferrules are component parts of studs. MATERIAL PLATING GAUGE D Low carbon steel Stainless steel AISI grade 302 WELD PINS DOUBLE POINTED (ARC) Copper coating is standard Does not apply to Stainless steel 10 Ga. (.135 ) MIN. L 3/4 THE MACHANICAL PROPERTIES VALUES FOR VARIOUS GRADES AVAILABLE UPON REQUEST. APPLICATION : Ideally suited for welding to surfaces covered with mill scale, rust, or paint. WASHERS : Self-locking washers are available in a variety of sizes, shapes, and materials. MATERIAL PLATING GAUGE D Low carbon steel Stainless steel AISI grade 302 WELD PINS SHORT CYCLE (ARC) Cooper coating is standard. Does not apply to Stainless steel. 10 Ga. (.135 ) MIN. L FD 3/4.250 THE MECHANICAL PROPERTIES VALUES FOR VARIOUS GRADE AVAILABLE UPON REQUEST. 4
6 APPLICATION : Ideally suited for welding to surfaces covered with mill scale, rust, or paint. WASHERS : Self-locking washers are available in a variety of sizes, shapes, and materials. MATERIAL PLATING GAUGE D Low carbon steel Stainless steel AISI grade 302 WELD PINS "SURE-FIRE" (CD) Cooper coating is standard. Does not apply to stainless steel 12 Ga (.105 ) 10 Ga. (.135 ) MIN. L 3/4 3/4 FD THE MECHANICAL PROPERTIES VALUES FOR VARIOUS GRADES AVAILABLE UPON REQUEST. APPLICATION : This weld pins is for use with resistance welding equipment DURO-DYNE. WASHERS : Self-locking washers are available in a variety of sizes, shapes, and materials. Low carbon steel Aluminum WELD PINS OVAL HEAD (DURO-DYNE) MATERIAL PLATING GAUGE D Copper coating is standard. Does not apply to Aluminum 16 Ga 14 Ga MIN. L FD 3/4 Au Besoin THE MECHANICAL PROPERTIES VALUES FOR VARIOUS GRADES AVAILABLE UPON REQUEST. 5
7 The cupped head weld pins from ALLIANCE will simplified your task for the permanent fixation of your insulation material and also for your other insulation product. These cupped head weld pin can easily be used with a standard capacitor discharge welding equipment. These cupped head weld pin from ALLIANCE are easy to order and we offer a large variety of size. We also have available a special model that can be adapt on your automatic weldind system used for the prefabrication of conducts and panels. All ALLIANCE cupped head pins are compatible and recommended for use with all brands of CD stud welding equipment. 6
8 1. HANG INSULATION 2. PRESS CUPPED HEAD WELD PIN THROUGH INSULATION. NOTE - An insulating paper washer is required here when welding through foil-faced insulation. 3. WELD IN PLACE TO COMPLETE INSTALLATION. For more information, consult your ALLIANCE field representative. 7
9 CUPPED HEAD WELD PIN TYPE WD D L Cupped head 1 1/2 12 Ga (.105) 3/8 Min Mini-Cupped head 1 3/16 12 Ga (.105) 3/8 Min BEVEL : Washer edge is beveled to prevent cutting of insulation material. STAINLESS STEEL : Not standard, but available by special order. PAPER INSULATING WASHERS : Available for welding through foil faced insulation. PLATING : Standard pin is copper plated and the standard washer is galvanized. MECHANICAL PROPERTIES : Values available upon request. LENGTH L Std. Box QTY Wgt/1000 Std Wgt/1000 Mini 3/ / / / / / / / / / / / / / LENGTH L Std. Box QTY Wgt/1000 Std Wgt/1000 Mini 2 3/ / / / / / / / / / / / CONTACT YOUR ALLIANCE SALES REPRESENTATIVE FOR INFORMATION ON SIZES, MATERIALS OR CONFIGURATIONS NOT SHOWN. 8
10 CUPPED HEAD WELD PIN TYPE WD D L Cupped head 1 3/16 12 Ga (.105) 3/8 Min BEVEL : Washer edge is beveled to prevent cutting of insulation material. STAINLESS STEEL : Stainless steel AISI grade Std.. PAPER INSULATING WASHERS : Available for welding through foil faced insulation. PLATING : Does not apply to Stainless steel. MECHANICAL PROPERTIES : Values available upon request. PART NUMBER CUPPED HEAD WELD PIN LENGTH L Wgt/M Std. Ctn Qty / / / / CONTACT YOUR ALLIANCE SALES REPRESENTATIVE FOR INFORMATION ON SIZES, MATERIALS OR CONFIGURATIONS NOT SHOWN. 9
11 LACING ANCHOR STYLE D L L Cup head 12 Ga (.105) 2 1/2 Min 4 1/2 Max Cup head 14 Ga (.080) 2 1/2 Min 4 1/2 Max FINISH : Mild Steel pins are galvanized, mild steel tops are zinc plated. MATERIAL : Low carbon Steel, 304 Stainless Steel. PAPER INSULATING WASHERS : Available for welding through foil faced insulation. MECHANICAL PROPERTIES : Values available upon request. ANNEALING : All stell Pins are fully annealed unless other wise specified. CUP HEAD WELD PINS FTC TYPE D WD L RESISTANCE /6 Min APPLICATION : This cup head weld pin is for use with DURO-DYNE auto feed resistance welding equipment and DURO-DYNE hand held resistance spotter guns. MATERIAL : Low Carbon Steel, pins and washers. PLATING : Standard pin is zinc plated and standard washer is galvanized. MECHANICAL PROPERTIES : Values available upon request. Contact your ALLIANCE sales representative for information on Sizes, Materials or Configurations not shown. 10
12 ALLIANCE Spindle, Insul-Anchors simplify the permanent installation to porous construction surfaces and non-weldable materials. They can be applied quickly and easily using only a pytty knife and ALLIANCE Hanger Adhesive. ALLIANCE Hanger Adhesive is available in 1 gallon cans. The coverage is approximately standard anchors with 2" x 2" plate per 1 gallon can. To complete the insulation fastening operation, ALLIANCE spindle Insul-Anchors are used in conjunction with ALLIANCE Self-Locking washers. For more information concerning the application of insul-anchors, refer to page 2 of this section. For more information concerning self-locking washer refer to the Washers, Caps and Nuts section, page 17 to 20 of this catalog. 11
13 1. WIPE SURFACE CLEAN. Anchor must be applied to a clean, dry, non-painted surface. 2. APPLY ADHESIVE TO ANCHOR. Spread a daub of hanger adhesive on to the perforated base with a putty knife. 3. OR... APPLY ADHESIVE TO ANCHOR. Or... cover the perforated base with Hanger adhesive from a caulking gun. 4. STICK ANCHOR IN PLACE. Press anchor into position with a twisting motion to assure an even spread of adhesive. The adhesive should protrude through the perforations and beyond the edges of the base. 5. HANG INSULATION. NOTE: ALLOW ADHESIVE TO DRY THOROUGHLY before hanging insulation, usually hours. Drying times vary with temperature. 6. SECURE WITH WASHER Secure insulation in place with a self-locking washer and then bend or clip off the spindle. FOR MORE INFORMATION, CONSULT YOUR NEARBY ALLIANCE FIELD REPRESENTATIVE. 12
14 D L 12 Ga 1 Min MATERIAL : Nail is Low carbon steel, copper coated. Base plate low carbon steel, galvanize. Also available by special order in all stainless steel or all aluminum. SIZE : 12 GA. (.105") IS STANDARD. Other sizes available by special order only. WASHERS: Self-locking washers 1" x 1 1/4" mild steel. PART NUMBER LENGTH L STD. CTN. QTY. Wgt/M Lbs / / / / / / CONTACT YOUR ALLIANCE SALES REPRESENTATIVE FOR INFORMATION ON SIZES, MATERIALS OR LENGTHS UP TO 21". 13
15 CALL 14
16 INSTANT ANCHOR PLACEMENT ALLIANCE Self-Stick Insul-Anchors simplify the permanent installation to non-porous construction surfaces and non-weldable materiels. They can be applied quickly and easily. Simply peel off the release backing, press in place, and then hang the insulation. There are no messy adhesives, or time-delay for adhesive curing. ALLIANCE Self-Stick Insul-Anchors are available with a 2" x 2" solid plate and 12 ga. spindle of varying lengths to meet your requirements. To complete the insulation fastening operation, ALLIANCE Self-Stick Insul-Anchors are used in conjunction with ALLIANCE Self-Locking Washers. For more information concerning the application of ALLIANCE Self-Stick Insul-Anchors, see the page 16 of this section. For more information concerning self-locking washers refer to the Washers, Caps and nuts section, page 17 to 20 of this catalog. 15
17 1. WIPE SURFACE CLEAN. Anchors must be applied to a clean, dry, non-porous surface. 2. PEEL OFF RELEASE BACKING. Double faced foam tape is 1/32 inch thick, with a one-year active shelf life. 3. STICK ANCHOR IN PLACE. Select location before contact with surface. Press firmly. 4. HANG INSULATION AND SECURE WITH WASHER. Recommende loading 3 lbs. per anchors. (.75 Lbs/sq. in. maximum) 16
18 D L 12 Ga 1 Min MATERIAL: Low carbon steel. Also available by special order in all Stainless steel or all Aluminum. SIZE : 12 GA (.105") is CHEVILLES standard. Other sizes DE available SOUDURE by special À TÊTE order only CUVETTE PLATING : Copper coating is standard, the plate is galvanized. WASHER : Self-locking washers are 1" x 1 1/4" mild steel. PART NUMBER LENGTH L STD. CTN. QTY. Contact your ALLIANCE representative for information on sizes or meterial not shown. Wgt/M Lbs / / / / / /
19 ALLIANCE Self-locking Washers are used in conjunction with ALLIANCE weld pins, insul-anchors and lacing anchors to fasten insulation in place. Simply press the self-locking washers onto the pin up against the insulation until the desired position is reached and then clip off, or bend over, the remaining portion of pin for a permanent attachment. The choice between Round or square self-locking washer is basically a matter of aesthetics or personal preference. The domed, multi-lanced hole design provides for ease of locating washer on weld pins and positive self-locking. Some styles of washers are manufactured with a beveled edge to prevent the washer from cutting into the insulation facing. ALLIANCE Self-locking washers are available with standard 10 GA, or 12 GA hole sizes off-the-shelf. Other material/plating combinations and hole sizes are available by special order. 18
20 TYPE S-250 S-150 S-125 SIZE 2 1/2 x2 1/2 1 1/2 x1 1/2 1 x 1 1/4 THICKNESS 0, HOLE 10 & 12 GA 10 & 12 GA 10 & 12 GA MATERIAL STEEL STEEL STEEL PLATING Galvanized Galvanized Galvanized EDGE BEVELED BEVELED BEVELED STD/CTN PART NUMBER STYLE HOLE GAUGE Wgt/M Lbs Std/Ctn S GA S GA S GA S GA S GA S GA PART NUMBER STYLE HOLE GAUGE Wgt/M Lbs Std/Ctn S GA S GA S GA S GA S GA S GA PART NUMBER STYLE HOLE GAUGE Wgt/M Lbs Std/Ctn S GA N/D S GA N/D S GA N/D S GA N/D S GA N/D S GA N/D
21 TYPE R-175 R-150 R-138 DIAMETER 1 3/4 1 1/2 1 3/16 THICKNESS 0, HOLE 10 & 12 GA 10 & 12 GA 14 & 12 GA MATERIAL MILD STELL MILD STEEL MILD STEEL PLATING GALV. GALV. GALV. EDGE FLAT BEVELED FLAT OTHER MATERIALS ALUM. / S.S. ALUM. / S.S. ALUM. / S.S. STD/CTN PART NUMBER STYLE HOLE GAUGE Wgt/M Lbs Std/Ctn R GA R GA R GA R GA R GA PART NUMBER STYLE HOLE GAUGE Wgt/M Lbs Std/Ctn R GA R GA R GA PART NUMBER STYLE HOLE GAUGE Wgt/M Lbs Std/Ctn R GA N/D 1000 Contact your ALLIANCE sales representative for prices or for information on sizes, materials, or configurations not shown. 20
22 CAPPED SPEED WASHER APPLICATION: Designed to permanently lock on 12 GA weld pin or insul-anchors where appearance is a major factor, or where no sharp points or edges are permissible on the surface. MATERIAL : Decorative Domed Cap - Aluminum Self-Locking Insert - Hardened Steel COLOR: Plain (bright aluminum). Other painted colors are available. PRONG WASHER (R175P) APPLICATION : Designed to be use with ATTACHES D.F. Prong Hanger. MATERIAL : Mild Steel (Galv.). SIZE: Hole size : 3/32 x 13/16 LACING WASHER & RING APPLICATION: Designed to be used with lacing wire to wrap insulation around irregular shapes. MATERIAL: Washer - Aluminum or Stainless Steel Ring - Zinc alloy, bright zinc plated. NO - AB: Washers are stamped NO AB to indicate non-asbestos material. ANNULAR RING CAP (For annular ring studs) APPLICATION: Designed to permanently lock on to Navy annular ring studs. MATERIAL: Aluminum or Plastic. SIZE: For 1/8" or 3/16" diameter studs. 21
23 D MIN L TD TL MAX FD MAX FH FERRULE CODE 5/16 21/32 3/16 11/ FB-5 Material: Low carbon steel Plating: Plating is not standard, but available upon request. Properties: Values for various alloys available upon request. Ferrule D L WD # 12 5/ Material: The pin is case hardened steel and the washer is low carbon steel Plating: The pin is zinc chromate and the washer is zinc. 22
CAPACITOR DISCHARGE(CD)
1 CAPACITOR DISCHARGE(CD) The capacitor discharge CD Pin is a Low Carbon Steel, Stainless Steel or Aluminum weld pin that is ideal to apply with pin welding or stud welding equipment. Manufactured with
More informationCOMPLEtE. COMPLEtE. STUD WELDING Products. STUD WELDING Products. Insulation Pins. section 6. Service Knowledge Integrity
Products Service Knowledge Integrity section 6 Insulation Pins FOR INQUIRIES, TO PACE ORDERS, SERVICE AND TECHNICA SUPPORT CONTACT ANY OF THE FOOWING: OFFICE: 216.904.4008 EMAI: SAES@COMPETESTUDWED.COM
More informationNote: Above dimensions will vary due to manufacturer s tolerances. Metric sizes also available.
1 Note: Above dimensions will vary due to manufacturer s tolerances. Metric sizes also available. 2 Note: Above dimensions will vary due to manufacturer s tolerances. Metric sizes also available. 3 Note:
More informationCD Capacitor Discharge The Process
CD Capacitor Discharge The Process. CD. Capacitor Discharge Why CD Studs are better CD. Capacitor Discharge General Specifications Weld Base: CD. Stud Load/Torque Strengths Stud Material Stud Size Maximum
More informationCAPACITOR DISCHARGE (CD) WELD STUDS & STUD WELDING EQUIPMENT
CAPACITOR DISCHARGE (CD) WELD STUDS & STUD WELDING EQUIPMENT THE WELDING PROCESS THE CAPACITOR DISCHARGE (CD) STUDWELDING PROCESS CD Studwelding is generally used to weld smaller diameter studs to thin
More information1470 Dale Court Austell, GA Phone: Fax:
1470 Dale Court Austell, GA 30168 Phone: 404-351-2202 Fax: 404-351-2203 LC METALS, INC. PRODUCT INDEX Page # STUD GUARDS...3 FHA STRAPS...3 BOCA PLATES (Nail Plates)...4 PLUMBERS TAPE (Banding Iron)...4
More informationCAPACITOR DISCHARGE (CD) STUD WELDING PROCESS
STUS (General Information) CAPACITOR ISCHARGE (C) STU WELING PROCESS 1. STU AGAINST WORK. 2. STORE ENERGY ISCHARGE THROUGH SPECIAL WEL TIMING TIP AN STU STARTS OWNWAR. 3. STU FORCE INTO MOLTEN METAL. 4.
More informationA. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.
SECTION 23 07 13 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationFAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System
FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System Product Focus F.A.S.T. System can be installed independent of the floor system. Stackable to create multiple tiers. No tools required
More informationARC WELD STUDS & ARC STUD WELDING EQUIPEMENT
ARC WELD STUDS & ARC STUD WELDING EQUIPEMENT ARC STUDS GENERAL INFORMATION THE ARC STUDWELDING PROCESS ARC Studwelding is generally used to weld larger diameter studs to thick base metals. ARC Studs may
More informationBeryllium-Copper Gaskets
STOCK SPRING-LINE Beryllium-Copper Gaskets SPRING-LINE Beryllium-Copper Gaskets SPRING-LINE beryllium-copper gaskets combine high levels of EMI shielding effectiveness with springfinger wiping and low
More informationStud Welding. What is stud welding and how does it work? The 12 most important questions and answers
I N F O Stud Welding What is stud welding and how does it work? The 12 most important questions and answers Time and cost savings New design potentials Unsurpassed economy Stud Welding Advantages... In
More informationStud Welding. What is stud welding and how does it work? The 12 most important questions and answers
I N F O Stud Welding What is stud welding and how does it work? The 12 most important questions and answers Time and cost savings New design potentials Unsurpassed economy Stud Welding Advantages... In
More informationRECTANGULAR RECTANGULAR RECTANGULAR TWO TINE THREE TINE CORRUGATED INSULTWIST BULL HORN Y ANCHOR SPLIT PIN T PLATE KNURLED
REFRACTORY STUDS RECTANGULAR RECTANGULAR RECTANGULAR TWO TINE THREE TINE CORRUGATED INSULTWIST BULL HORN Y ANCHOR SPLIT PIN T PLATE KNURLED *OTHER STUDS AVAILABLE ON REQUEST. 11-1 Houston, Texas 77040-4915
More informationMechanical Properties - Standard. Standard Mild Steel Studs AWS Type A
General Material Specifications Material Specifications Nelson s studs may be made of one of the following materials, as specified on individual specification sheets. Certificates of chemical analysis
More information1. Building insulation in batt form. 2. Rigid board insulation. 3. Cavity wall insulation.
SECTION 07210 BUILDING INSULATION PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification Sections,
More informationComplete. COMPLEtE. STUD WELDING Products. STUD WELDING Products. stud arc welding Introduction. section 1. Service Knowledge Integrity
Complete Products Service Knowledge Integrity section 1 stud arc welding Introduction FOR INQUIRIES, TO PLACE ORDERS, SERVICE AND TECHNICAL SUPPORT CONTACT ANY OF THE FOLLOWING: OFFICE: 216.904.4008 EMAIL:
More informationDIVISION 5 - STRUCTURAL STEEL AND IRON WORK
DIVISION 5 - STRUCTURAL STEEL AND IRON WORK SECTION 05100 STRUCTURAL METAL FRAMING PART 1.00 GENERAL 1.01 SCOPE OF WORK A. Work Included: 1. 2. Structural steel complete in place. Steel joists complete
More informationModular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper
Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)
More informationA. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.
SECTION 230713 DUCT INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationWelding Elements Catalogue
Quality meets Innovation Welding Elements Catalogue 2017 - Welding Elements Catalogue Welding Elements Welding Elements Catalogue Issue 06/2017 Transmission and duplication of this document, dissemination
More informationHilti Cable Transit System. More safety on board. Hilti. Outperform. Outlast.
Hilti Cable Transit System More safety on board. Hilti. Outperform. Outlast. 2 For a safe passage. The versatile Hilti Cable Transit System. Fire-resistant, watertight and gastight. 3 You can depend on
More information5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE
5.0 NUDURA PRODUCTS ON SITE STORAGE PACKAGING, UNIT ASSEMBLY, USAGE NUDURA Inc. has one of the most complete lineups of products and accessories available today in the construction industry. NUDURA s Integrated
More informationSection 906. STRUCTURAL STEEL
906.01 Section 906. STRUCTURAL STEEL 906.01. General Requirements. Finished rolled shapes must be free from imperfections that affect strength and durability in accordance with ASTM A 6. Rolled shapes
More informationD D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.
Sign length minus Adjust to avoid interference with sign legend A Deck fascia A 6" Equal Equal 6" Sign length (L) varies 6 to 12 PLAN 0 CONNECTION (DECK FASCIA) Angle connection assembly F Face of concrete
More information05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES
PART 1 GENERAL 1.01 DESCRIPTION A. The Vendor shall fabricate, furnish, test and deliver tapered steel trolley poles, including base plates, reinforced hand holes, anchor bolts, nuts and washers, and accessories
More informationMaterials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.
Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon
More informationSUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)
1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12
More informationPROJ. NO SECTION HVAC DUCT INSULATION
SECTION 23 07 13 HVAC DUCT INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationFlextray - Accessories
Flextray - 40 Flextray - Protects cable from debris and dust Adds security to cable installation Easy bend-over tabs secure cover to trays Available for 2 (50mm) to 24 (600mm) wide trays Comes in 118 (2997mm)
More informationDESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7
DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification
More informationFIRE STATION 55 June 14, 2010
SECTION 15250 MECHANICAL INSULATION PART 1 - GENERAL 1.01 DESCRIPTION A. Work Includes 1. Insulation of Domestic Water Piping. 2. Pipe Insulation of refrigerant piping. 3. Insulation of ductwork. 4. Aluminum
More informationFire Barrier Duct Wrap 615+
Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire
More informationFig. 1 - Standard Clevis Hanger
Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension
More informationSection 5 Panels & Accessories
Contents Section 5 Panels 74-76 Stiffener/Handle 79 Wire Mesh 75 Sliding Door Guide 80 Panel Mounting locks 77 Rolling Door Guide 81 Mesh Retainers 78 ifold Door Glide 82-83 Mesh Clamp 79 T-Clips 84 Panels
More informationDesign & Installation Manual
Design & Installation Manual Insert Registered Legal Entity name, address and number, or all other details as required to comply with regional regulations Ceramic Fibre Lining Systems CONTENTS Introduction
More informationDSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION
SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method
More informationBlue Barrier Flash N Wrap 2400
Tools/Materials Needed 2 or 5 gal pail of Poly Wall Blue Barrier Flash N Wrap 2400 10.1 oz caulking or 20 oz. sausage tube of Poly Wall Blue Barrier 2200 Joint Filler Caulking (cartridge or sausage) gun
More informationFabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.
SECTION - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.
More informationSECTION COLD-FORMED METAL TRUSSES
SECTION 054400 COLD-FORMED METAL TRUSSES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationTHERMAL ISOLATION CLIP
THERMAL ISOLATION CLIP Installation Guide INSTALLATION BEST PRACTICE GUIDE The following is recommended for all wall installations: Familiarize yourself with the shop drawings. Where there is a difference
More informationSECTION METAL ATHLETIC LOCKERS
SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More informationAddendum to Specifications
Addendum to Specifications SOW #: Construction Specification #: Date: Additions to Specifications: Deletions to Specifications: Engineer Date Design Engineering Manager Date Page 2 of 7 PART 1 - GENERAL
More informationSECTION MISCELLANEOUS METALS
PART 1 GENERAL 1.1 WORK OF THIS SECTION A. Contractor shall provide all labor, materials, equipment and incidentals as shown, specified and required to furnish and install all miscellaneous metal fabrications
More informationModel # 940SM-P8. Page 1 of 10
Model # 940SM-P8 Page 1 of 10 Page 2 of 10 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all items for one full year to be free of defects in
More informationSECTION ALTERNATING TREAD STEEL STAIRS
SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and install carbon steel or stainless steel alternating tread stair assemblies in accordance with the requirements
More informationSECTION STRUCTURAL STEEL
SECTION 05120 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this
More informationSECTION TIMBER FLOATS
SECTION 06210 PART 1 - GENERAL 1.01 SUMMARY A. This section covers furnishing and installing the timber float framing for the pile guide area, and all other components not specifically mentioned, necessary
More informationInterior Hangers. Application
Application Interior bridge deck hangers are typically fabricated using two heavy duty sheet metal end clips that have been electrically resistance welded to an appropriate sized wire or formed metal connecting
More informationSPECIFICATION & DESIGN MANUAL " AISI 1060 to 1065 Rockwell Hardness 51 to 55 Perma-Seal coated Stick-E Pin 3/4" (Step Shank) 1"
Trak-It /Stick-E TM SPECIFICATION & DESIGN MANUAL TM Stick-E Electrical and Mechanical Fastening System PRODUCT DESCRIPTION The Stick-E fastening system uses Trak-It gas technology with specially designed
More informationB. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.
SECTION 10 5113 - METAL LOCKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationEasy to Use A7 Saves You Time and Money
ADHESIVE ANCHORING SPECIALISTS Easy to Use Saves You Time and Money DESCRIPTION/SUGGESTED SPECIFICATIONS* Fast Dispensing, Fast Curing The acrylic resin and hardening agent are completely mixed as they
More informationLight Stainless Flexible Liner
Light Stainless Flexible Liner Dalsin Line light flexible liner is listed for chimney relining and is suitable for wood, pellet, gas, oil, and coal applications. This liner is manufactured using.006 thick
More informationSECTION ALTERNATING TREAD STEEL STAIRS
SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this
More informationMatch your Inspection Ports to your Process Temperatures
ACCESS PLUG FLANGE, INC. The Worldwide Leader In Inspection Port Technology. O 1200 F Match your Inspection Ports to your Process Temperatures O 600 F O -32 F O -185 F Match your Inspection Ports to your
More informationMetal Framing Channels Overview
New Trivalent Galv-Krom Finish Is RoHS Compliant Thomas & Betts is proud to introduce the new and improved Trivalent Galv-Krom finish. Galv-Krom finish is a combination of.5 mils electro-plated Zinc and
More informationModel # PR /21/2018 Page 1 of 10
Model # PR-32 11/21/2018 Page 1 of 10 1/21/2018 Page 2 of 10 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationModel # 238HS-P8. 4/27/2011 Page 1 of 11
Model # 238HS-P8 4/27/2011 Page 1 of 11 4/27/2011 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationDuct Wrap Flexible Wraps
Design No. 3MU/ 60-01 December 23, 2010 VENTILATION DUCT PROTECTION 3M Company 3M Fire Barrier Duct Wraps: 615 and 615+ 3M Fire Barrier Sealants: Water-Tight 1000-NS Silicone, Water-Tight 1003-SL Silicone
More informationSECTION WALL AND DOOR PROTECTION
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 26 00 WALL AND DOOR PROTECTION SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable to
More informationModel # 940SM-V8. Page 1 of 10
Model # 940SM-V8 Page 1 of 10 Page 2 of 10 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all items for one full year to be free of defects in
More informationSECTION 716 SIGN MATERIALS SCOPE
716 716.01.01 MATERIALS COVERED SECTION 716 SIGN MATERIALS SCOPE A. This specification covers the kind and quality of materials used in the construction and fabrication of traffic control devices used
More informationK. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.
DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:
More informationIMAGE INDUSTRIES INC. STUD WELDING CATALOG. Attachment Systems Cold Formed Parts Assemblies
IMAGE INDUSTRIES INC. STUD WELDING CATALOG Attachment Systems Cold Formed Parts Assemblies ! WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED IN THIS CATALOG
More informationGOWANDA, NEW YORK SEPTEMBER 18, 2008 ARCH PROJECT NO
SECTION 07210 BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationFAST-09. Flextray F.A.S.T. System The Next Generation RF Solution
FAST-09 Flextray F.A.S.T. System The Next Generation RF Solution Product Focus F.A.S.T. System can be installed independent of the floor system. Stackable to create multiple tiers. No tools required for
More informationSECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 081113 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationWorkmanship Acceptance Standards
Workmanship Acceptance Standards Subject: O.D and I.D tolerances and concentricity Scope: To establish common practice for specifying tolerances of outside and inside diameters and concentricity of washers.
More informationSECTION METAL STAIRS
SECTION 05510 METAL STAIRS PART 1 GENERAL 1.01 SECTION INCLUDES A. Stairs with concrete treads. B. Stairs with metal treads. C. Structural steel stair framing and supports. D. Handrails and guards. 1.02
More informationSECTION ALUMINUM HANDRAIL SYSTEMS
SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American
More informationNorthpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017
SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationModel # 504S-P. 9/14/2011 Page 1 of 9
Model # 504S-P 9/14/2011 Page 1 of 9 9/14/2011 Page 2 of 9 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationCONCRETE STEPS, HANDRAILS, AND SAFETY RAIL
CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART 1 - GENERAL 1.01 SECTION INCLUDES A. Concrete Steps B. Handrails C. Safety Rail 1.02 DESCRIPTION OF WORK A. Construction of concrete steps. B. Furnishing
More informationSECTION PERFORATED METAL. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 05735 PERFORATED METAL Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Architectural metal. B. Decorative metal. C. Perforated ceiling panels.
More informationMAKING IT STICK: Nails and screws, adhesives and compounds... today contractors have a wide variety of choices.
MAKING IT STICK: Fasteners & Adhesives Walls hold up the building but what holds up the walls? Today contractors have a wide variety of fasteners and adhesives from which to choose, according to the needs
More informationPROJECT SUBMITTAL. Power-Stud TM. Wedge Expansion Anchor PROJECT SUBMITTAL CONTENTS APPROVALS AND LISTINGS
PROJECT SUBMITTAL Power-Stud TM Wedge Expansion Anchor Anchoring into Solid Concrete and Masonry Base Materials Anchor Diameter is the Same as the Hole Diameter Interlocking Clip Wedges Prevent Anchor
More informationModel # 362S-RDP. 9/17/2012 Page 1 of 12
Model # 362S-RDP 9/17/2012 Page 1 of 12 9/17/2012 Page 2 of 12 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationProduct Warranty Every VERSABAR product has been carefully inspected during manufacturing, and prior to shipment. We guarantee to correct any defect called to our attention in writing within six months
More informationGuide Specifications ADP Series SECTION SHEET METAL ROOFING
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]
More informationModel # 158-P4. 12/12/2013 Page 1 of 11
Model # 158-P4 12/12/2013 Page 1 of 11 2/12/2013 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationModel # 940S-P6-BB. 6/7/2017 Page 1 of 10
Model # 940S-P6-BB 6/7/2017 Page 1 of 10 /7/2017 Page 2 of 10 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationA. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.
SECTION 09512 - ACOUSTICAL TILECEILINGS (ACT-01 and ACT-02) PART 1 - GENERAL 1.01 SUMMARY A. Section includes ceilings consisting of acoustical panels and exposed suspension systems. This ceiling system
More informationFitTech UP171F ELLIPTICAL (FOOTING) UP171I ELLIPTICAL (IN GROUND) UP171S ELLIPTICAL (SURFACE) Parts List
ELLIPTICAL BASE COVER DESCRIPTION FOOTBUCK WELD ASS'Y HARDWARE COMPLETE HARDWARE COMPLETE HARDWARE COMPLETE /" ANCHOR ROD 3/" x " HEX HEAD CAP SCREW 3/" WEDGE ANCHOR 3/" ANCHOR BOLT 3/" FLATWASHER (" O.D.)
More informationModel # BARK /26/2012 Page 1 of 5
Model # BARK-430 6/26/2012 Page 1 of 5 6/26/2012 Page 2 of 5 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic/Canine
More informationSECTION METAL ATHLETIC LOCKERS
SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified
More informationSECTION HVAC INSULATION
PART 1 GENERAL 1.1 SUMMARY SECTION 23 07 00 HVAC INSULATION A. Section Includes: 1. Ductwork insulation. 2. Duct liner. 3. Insulation jackets. 4. Equipment insulation 5. Piping system insulation. 6. Insulation
More information94110 Vacuum Vent. Features. Vacuum Vent. Less need for special materials in corrosive and extreme temperature
The Shand & Jurs 94110 has been designed utilizing over 90 years experience in the development of quality safety and conservation fi ttings. The function of this vent is to relieve vacuum conditions in
More information1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.
BID OPPORTUNITY NO. 253-2011 PAGE 1 OF 7 PART 1 GENERAL 1.1 REFERENCES.1 American Society of Mechanical Engineers (ASME).1 ASME B31.1, Power Piping, B31.3 Process Piping, B31.9 Building Services Piping..2
More informationMarine & Offshore Fire Divisions
Marine & Offshore Fire Divisions bulkhead & deck systems U-FW/GMM EN Rev: 2 Sept 18 Contents Page No. Introduction Installation Surface Coverings - General Principles - Anchors - System Repair and Maintenance
More informationPOST FRAME BUILDING STANDARDS
CASS COUNTY, MISSOURI BUILDING CODES, ENVIRONMENTAL HEALTH AND ZONING DEPARTMENT 30508 S. West Outer Road, Harrisonville, MO 64701 P- (816) 380-8134 F- (816) 380-8130 POST FRAME BUILDING STANDARDS 201.3
More informationWEC Manufacturing Phone: (901) Website: Itswec.com
All Welded Plus Series Part 1: General 1.1 Construction Requirements: All lockers shall be powder coated steel as design and manufactured by WEC, Memphis, Tennessee. WEC will furnish all labor and materials
More informationB. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.
SECTION 055116 - METAL FLOOR PLATE STAIRS PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationMounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.
The Knife Edge Cove is a modular lighting system consisting of two parts: 1- An aluminum fixture housing extrusion 2- Drop-in lighting modules The fixture will provide a continuous knife edge architectural
More information94115 Vacuum Vent (Side Mounted) Features. Vacuum Vent (Side Mounted) Side Mounted
94115 The Shand & Jurs 94115 Vacuum Vent has been designed utilizing over 90 years experience in the development of quality safety and conservation fittings. The function of this vent is to relieve vacuum
More informationTOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations
TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with
More informationDivision 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17
07 21 16 Blanket Insulation Page 1 of 17 Design Number UNI/BI 120-03 FIRE RESISTANT GREASE DUCT Unifrax I LLC FyreWrap Elite 1.5 Duct Insulation CAN/ULC S144 Fire Resistance Rating 2 hours Fire Inside
More informationStainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties
Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties Stainless steel describes a family of steels highly resistant to tarnishing and rusting that contain at least two
More informationModel #369S-PR. 8/23/2016 Page 1 of 11
Model #369S-PR 8/23/2016 Page 1 of 11 /23/2016 Page 2 of 11 1675 Locust Street Red Bud, IL 62278 Phone: 618-282-8200 Fax: 618-282-8202 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic
More informationM-SERIES INSTALLATION
M-SERIES INSTALLATION Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND LISTED
More informationB R OA DWAY RAC K. High Security
B R OA DWAY RAC K High Security The Broadway Rack is a great fit on Broadway or in areas where maximum security is a top priority. Made of thick, two-inch square steel, the Broadway Rack renders pipe-cutters
More information