HDX-MS at Waters Waters Corporation 1
|
|
- Neil Wade
- 6 years ago
- Views:
Transcription
1 HDX-MS at Waters 2011 Waters Corporation 1
2 Hydrogen Deuterium Exchange MS systems Dedicated standards and UPLC BEH separation chemistries nanoacquity UPLC with HDX technology Xevo G2-S QTof MS and Synapt G2-Si HDMS ProteinLynx Global Server (PLGS) and DynamX data processing 2011 Waters Corporation 2
3 Waters System Solution for Automated HDX nanoacquity UPLC with HDX Automation technology Synapt G2-Si HDMS ProteinLynx Global SERVER (PLGS) DynamX TM Fast chromatography at 0 C Automates HDX experiments Accurate measurement ETD capability Ion mobility Reliable peptic peptide ID by MS E Automated HDX data Processing for deuteration determination 2011 Waters Corporation 3
4 Waters HDX Workflow at the Peptide Level Relative Deuterium Level (Da) peptide APO HOLO Time (min) Undeuterated / H2O Deuterated / D2O Protein in H 2 O, ph 7.40 at room temp Add 20-fold excess D 2 O Protein labeling occurs For various times Quench ph to 2.50, temp to 0 C OPTIONAL AUTOMATION Inside HDX Manager at 0 C Quenched protein is injected into HDX manager at ph 2.5 Local Analysis at Peptide Level Online Pepsin Digestion ph 2.50 nanoacquity UPLC using 1.7 µm BEH130 C18 column for fast separation Peptide map PLGS and IDENTITY E for peptide ID ESI Q - Tof MS E Or ESI HDMS E Deuterium Uptake DynamX Processing Determination 2011 Waters Corporation 4
5 Measurement of average mass change over time Labeling time 240 m 60 m 100 % % Uptake of deuterium from 0 solution for different regions 100 vary according to time % % 0 10 m 1 m 100 % % % % 0 Changes in mass (distribution) correlated to conformational changes s % % 0 0 s 100 % 0 Time % 0 m/z Waters Corporation 5
6 Waters M-Class ACQUITY UPLC with HDX Technology Waters next generation UPLC platform for nano to microscale separations True UPLC separations for protein and peptide-level HDX-MS measurements Reproducible, rapid and robust separations at 0 degrees C up to 15K psi 2011 Waters Corporation 6
7 Complex HDX Data can be Resolved by enabling Ion Mobility Iacob et al; Ion Mobility adds an additional dimension to mass spectrometric analysis of solutionphase hydrogen/ deuterium exchange; Rapid Commun. Mass Spectrom. 2008; 22: Waters Corporation 7
8 IMS separates co-eluting labeled peptides UCA064_100901_077_bsa_2m 287 (3.504) Cm (278:306) 100 1: TOF MS ES+ 9.08e4 2 m Labeling No IMS separation % 0 m/z Ion Mobility Enabled, p,,, p ( p) UCA064_100901_077_bsa_2m_rt_04_JA2 291 (3.567) Cm (278:294) 1: TOF MS ES e4 ASIQKFGERALKA 2+ % with IMS-enabled separation 0 m/z UCA064_100901_077_bsa_2m_rt_04_JA 284 (3.472) Cm (278:294) 1: TOF MS ES e3 % AVEGPKL 1+ 0 m/z UCA b (3 504) C ( ) 1 TOF MS ES 2011 Waters Corporation 8
9 Ion Mobility Separation No Deuterium Exposure 2011 Waters Corporation 9
10 Ion Mobility Separation 100 Minute Exposure 2011 Waters Corporation 10
11 Waters HDX software: DynamX TM Automated uptake calculation Easy view Convenient interpretation 2011 Waters Corporation 11
12 DynamX: IMS Support 100 min Time Course Changes in Uptake 10 min Peptide Identified Interfering Peptide separated by Mobility 1 min 10 sec Ref 2011 Waters Corporation 12
13 Understanding the Difference Plot Difference plots represent uptake (Da) differences between ref and exp. A black vertical bar represents a sum of the mass differences observed for each peptide in all time points. Ref (IFN) Confidence limit Black dotted line at y-axis values +1.1 Da Time-course 10 sec 1 min 12 min 60 min 240 min Blue dotted line at y-axis values +0.5 Da Vertical bar Indicates that this peptide showed higher uptake in Oxidized IFN. Exp (Oxidized IFN) What it means These displays are available in DynamX software (except confidence limit). In this data, certain peptides with the significant differences can be easily visualized. In this case, oxidized IFN revealed significant conformational changes in several peptides. Houde, et. al. J. Pharm. Sci June 1;100(6): Waters Corporation 13
14 HDX for Comparability: Experimental Butterfly Chart How different are the two conditions? Butterfly Chart reveals the exchange rate and deuteration incorporation in comparison for all peptides in all time points. APO Where is the peptide #43? Residues AA, localising the contribution to the difference HOLO 2011 Waters Corporation 15
15 Leap HDX Automation Manager Independent temperature zones for automated sampling processing HDX manager 2011 Waters Corporation 16
16 Automated Waters HDX-MS system 2011 Waters Corporation 17
17 Enzymate Online Digestion Column Pepsin immobilized BEH column, Waters P/N mm X 30 mm 15,000 psi compatibility 2011 Waters Corporation 18
18 HDX Phos B Check Standard Intact phosphorylase b protein that can be used to evaluate HDX system performance, measure back exchange, and optimize methods P/N Waters Corporation 19
19 HDX/ETD Workflow ETD/HDX can pinpoint conformational changes to a single AA residue ETD presents a practical alternative to fragmentation techniques for high-spatial-resolution HDX studies 2011 Waters Corporation 20
20 ETD with the SYNAPT G2-Si System Front-end ETD using glow discharge source Compatible with LC separations Permanently mounted Easy operation & maintenance 2011 Waters Corporation 21
21 ETD/HDX Data can Provide Near AA Residue Spatial Resolution of D Uptake 2011 Waters Corporation 22
22 Inlet Editor 2011 Waters Corporation 23
23 Example Inlet Method 2011 Waters Corporation 24
24 Example Inlet Method Binary Solvent Manager Example gradient is for a 1.0 x 50 mm HSS T3 column. If using a 1.0 x 100 mm BEH column, typical flow rates are 40 to 45 µl/min Fluidic Configuration is set for Single Pump Trapping 2011 Waters Corporation 25
25 Example Inlet Method Binary Solvent Manager Trapping flow for the BSM should be set to be identical as the initial gradient conditions. Sample loading time (trapping and digestion) is set on this tab Waters Corporation 26
26 Example Inlet Method Auxiliary Solvent Manager The ASM flow rates have been increased to 1000 µl/min. Once software has been released, the ASM will be capable of different flow rates for both analytical and trapping conditions Waters Corporation 27
27 Example Inlet Method HDX Manager The HDX Manager has independent settings for the digestion and chamber temperature Waters Corporation 28
28 Example Inlet Method HDX Manager Data channels must be activated. Errors will occur if they are not Waters Corporation 29
29 Source Conditions 2011 Waters Corporation 30
30 Instrument 2011 Waters Corporation 31
31 TriWave 2011 Waters Corporation 32
32 TriWave DC 2011 Waters Corporation 33
33 MSe and HDMSe HDMS E Training April Waters Corporation 34
34 UPLC/HDMS E deconvoluting chimericy Co-Eluting Peptides Ionized Precursors Precursors IMS Separated Precursors Transferred to TOF MS 2011 Waters Corporation 35
35 UPLC/HDMS E deconvoluting chimericy Co-Eluting Peptides Ionized Precursors Precursors IMS Separated Precursors & Products Time Aligned 2011 Waters Corporation 36
36 UPLC/HDMS E Ion mobility 2011 Waters Corporation 37
37 IMS MS E MS Method Settings Waters Corporation 38
38 IMS MS E MS Method Settings Waters Corporation 39
39 IMS MS E MS Method Settings 30 Lockspray sampling set to every 30 seconds Waters Corporation 40
Overview of Waters Solutions for Biopharmaceutical Analysis and Characterization
Overview of Waters Solutions for Biopharmaceutical Analysis and Characterization Denis Calnan Biopharma Business Development Manager (Northern Europe) 2011 Waters Corporation 1 About Waters Facts and Figures
More informationSasidhar N. Nirudodhi, Lin Tzihsuan, Justin Sperry, Jason C. Rouse, James A. Carroll
Impact of Sequence Variants on the Higher-Order Structure (HOS) of Monoclonal Antibodies Using an Optimized HDX- MS Method with a Dual-Protease Co-Immobilized Column Format Sasidhar N. Nirudodhi, Lin Tzihsuan,
More informationBiotherapeutic Non-Reduced Peptide Mapping
Biotherapeutic Non-Reduced Peptide Mapping Routine non-reduced peptide mapping of biotherapeutics on the X500B QTOF System Method details for the routine non-reduced peptide mapping of a biotherapeutic
More informationExploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma
Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma Yun Wang Alelyunas, Mark D. Wrona, Jim Murphy, Angela Doneanu, Gregory
More informationProteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1
Routine Characterization of mabs and Other Proteins Patrick Boyce Biopharmaceutical Marketing Manager Europe and India 2011 Waters Corporation 1 Agenda Why? What scientific challenges? Technology Example
More informationADVANCING ATTRIBUTE CONTROL OF ANTIBODIES AND ITS DERIVATIVES USING HIGH RESOLUTION ANALYTICS
ADVANCING ATTRIBUTE CONTROL OF ANTIBODIES AND ITS DERIVATIVES USING HIGH RESOLUTION ANALYTICS Henry Shion 1, Jing Fang 1, William Alley 1, Barbara Sullivan 2, Nick Tomczyk 3, Liuxi Chen 1, Ying-Qing Yu
More informationMaximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns
Maximizing Chromatographic Resolution of Peptide Maps using UPLC with Tandem Columns Hongwei Xie, Martin Gilar, and Jeff Mazzeo Waters Corporation, Milford, MA U.S. APPLICATION BENEFITS The ACQUITY UPLC
More informationProteomics Training Kit
CONTENTS I. INTRODUCTION II. STANDARD PREPARATION III. PROTEIN EXPRESSION: MASSPREP MIX 1 VS. MIX 2 (75 µm) IV. PROTEIN EXPRESSION: MASSPREP MIX 1 VS. MIX 2 (300 µm) V. ORDERING INFORMATION I. INTRODUCTION
More informationAdvantages of Ion Mobility QTOF for Characterization of BioPharma Molecules
Advantages of Ion Mobility QTOF for Characterization of BioPharma Molecules Add a New Dimension to your Research Capability with Agilent s New Drift Ion Mobility QTOF System David Wong, Ph.D. Sr. Application
More informationAn Unbiased Approach to Increasing Proteome Coverage Using Ion Mobility with MS E
An Unbiased Approach to Increasing Proteome Coverage Using Ion Mobility with MS E John Rontree 2011 Waters Corporation 1 Current Issues with Protein Identification in Complex Mixtures Poor reproducibility
More informationGenerating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI
with the Biopharmaceutical Platform Solution with UNIFI Vera B. Ivleva, Ying Qing Yu, Scott Berger, and Weibin Chen Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S The ability to
More informationHigh throughput analysis at microscale: performance of ionkey/ms with Xevo G2-XS QTof under rapid gradient conditions
JOURNAL OF APPLIED BIOANALYSIS, October 2015, p. 128-135. http://dx.doi.org/10.17145/jab.15.021 (ISSN 2405-710X) Vol. 1, No. 4 APPLICATION NOTE High throughput analysis at microscale: performance of ionkey/ms
More informationHigh throughput analysis at microscale: performance of ionkey/ms with Xevo G2-XS QTof under rapid gradient conditions
JOURNAL OF APPLIED BIOANALYSIS, October 2015, p. 128-135. http://dx.doi.org/10.17145/jab.15.021 (ISSN 2405-710X) Vol. 1, No. 4 APPLICATION NOTE High throughput analysis at microscale: performance of ionkey/ms
More informationUNIFI: an innovative enabling platform Ken Eglinton Nordic User Training, September 2013
UNIFI: an innovative enabling platform Ken Eglinton Nordic User Training, September 2013 2013 Waters Corporation 1 Waters Laboratory Informatics Product Portfolio MassLynx Mass Spectrometry Software NuGenesis
More informationBiotherapeutic Peptide Mapping Information Dependent Acquisition (IDA) Method
Biotherapeutic Peptide Mapping Information Dependent Acquisition (IDA) Method Routine biotherapeutic accurate mass peptide mapping analysis on the X500B QTOF System Method details for the routine peptide
More informationMethod Development of a 2D LC-HRMS Extraction and Detection Method for Organophosphorus Flame Retardants in Environmental Water Samples
Method Development of a 2D LC-HRMS Extraction and Detection Method for Organophosphorus Flame Retardants in Environmental Water Samples Ken Rosnack 1 Lauren Mullin 1,2, Malorie Mella 1, Claude Mallet 1,
More information2012 Waters Corporation 1
UPLC User meeeting April 2012 Principles and Practices for SEC, IEX for Intact Protein Analysis by UPLC anders_feldthus@waters.com 2012 Waters Corporation 1 Agenda Ion-Exchange Chromatography Theory and
More informationENHANCED MS WITH THE TURN OF A KEY
[ ionkey/ms ] ENHANCED MS WITH THE TURN OF A KEY EXPERIENCE THE FUTURE OF MS, EXPERIENCE ionkey/ms THE LC-MS YOU KNOW, LIKE YOU VE NEVER SEEN BEFORE ionkey/ms Systems integrate the UPLC separation into
More informationSolutions Guide. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications
Solutions Guide MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications Page 1 of 12 Table of Contents Sample Injection... 3 Two- Selection... 4
More informationMichael J. Chalmers and Patrick R. Griffin
SUPPORTING INFORMATION A Two-Site Evaluation of the Repeatability and Precision of an Automated Dual-Column Hydrogen / Deuterium Exchange Mass Spectrometry Platform David J. Cummins 1, Alfonso Espada 2,
More informationDevelopment and evaluation of Nano-ESI coupled to a triple quadrupole mass spectrometer for quantitative proteomics research
PO-CON138E Development and evaluation of Nano-ESI coupled to a triple quadrupole mass spectrometer for quantitative proteomics research ASMS 213 ThP 115 Shannon L. Cook 1, Hideki Yamamoto 2, Tairo Ogura
More informationWaters Solutions for DMPK and Biomarker Analysis. Waters User Meeting ASMS 2011 Denver, Colorado. Stephen McDonald
Waters Solutions for DMPK and Biomarker Analysis Waters User Meeting ASMS 2011 Denver, Colorado Stephen McDonald 2011 Waters Corporation 1 Drug Development Process Pre-clinical testing R&D - 18 months
More informationHichrom Limited 1 The Markham Centre, Station Road, Theale, Reading, Berkshire, RG7 4PE, UK Tel: +44 (0) Fax: +44 (0)
Hichrom Limited 1 The Markham Centre, Station Road, Theale, Reading, Berkshire, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email: www.hichrom.co.uk Table of Contents Sample Injection...
More informationA highly sensitive and robust 150 µm column to enable high-throughput proteomics
APPLICATION NOTE 21744 Robust LC Separation Optimized MS Acquisition Comprehensive Data Informatics A highly sensitive and robust 15 µm column to enable high-throughput proteomics Authors Xin Zhang, 1
More informationDeveloping Quantitative UPLC Assays with UV
Developing Quantitative UPLC Assays with UV Detection for Antibodies & Other Proteins Steve Taylor 2011 Waters Corporation 1 Outline UPLC technology for RP protein separations Method development parameters
More informationAdvances in HDX Techniques
Waters HDX 24 meeting Advances in HDX Techniques Thomas J. D. Jørgensen Associate professor, Ph.D. Department of Biochemistry and Molecular Biology, University of Southern Denmark, Odense Part I Structural
More informationAdvanced Characterization of Antibody Drug Conjugates (ADCs) by Liquid Chromatography and Mass Spectrometry (LC/MS) John Gebler, Ph.D.
Advanced Characterization of Antibody Drug Conjugates (ADCs) by Liquid Chromatography and Mass Spectrometry (LC/MS) John Gebler, Ph.D. Director www.waters.com/adc 2015 Waters Corporation 1 2015 Waters
More informationIllicit Drug Analysis in Urine Using 2D LC-MS/MS for Forensic Toxicology
Claude Mallet 1 and Sabra Botch-Jones 2 1 Waters Corporation, Milford, MA, USA 2 Boston University School of Medicine, Boston, MA, USA APPLICATION BENEFITS Fast extraction protocol (2 min) 1 ppt detection
More informationApplication Note LCMS-87 Automated Acquisition and Analysis of Data for Monitoring Protein Conjugation by LC-MS Using BioPharma Compass
Application Note LCMS-87 Automated Acquisition and Analysis of Data for Monitoring Protein Conjugation by LC-MS Using BioPharma Compass Abstract Here we describe the development and use of an automated
More informationAutomatic Combination of Orthogonal Separation Modes for Multiple Components in Mixtures
Automatic Combination of Orthogonal Separation Modes for Multiple Components in Mixtures Thomas E. Wheat, Amanda B. Dlugasch, and Patricia R. McConville Waters Corporation IFPAC January 26, 2016 2016 Waters
More informationMicroflow LC-MS with the turn of a key
[ ionkey/ms ] Microflow LC-MS with the turn of a key Dramatically enhance your sensitivity for both quantitative and qualitative chromatographic data, with an integrated microflow LC-MS solution that is
More informationA Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics
A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics Catalin Doneanu,, Ph.D. Biopharmaceutical Sciences, Waters September 16, 2009 Mass Spec 2009 2009 Waters Corporation Host Cell Proteins
More informationSean M. McCarthy and Martin Gilar Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL RESULTS AND DISCUSSION
UPLC Separation of DNA Duplexes Sean M. McCarthy and Martin Gilar Waters Corporation, Milford, MA, U.S. INTRODUCTION Over the past 2 years there has been a considerable amount of effort focused on the
More informationMethod Development Considerations for Reversed-Phase Protein Separations
Method Development Considerations for Reversed-Phase Protein Separations Hillary B. Hewitson, Thomas E. Wheat, Paula Hong, Kenneth J. Fountain APPLICATION BENEFITS n The BEH00 C 4 chemistry is available
More informationRapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins
Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins Esther Lewis, 1 Kevin Meyer, 2 Zhiqi Hao, 1 Nick Herold,
More informationIsotopic Resolution of Chromatographically Separated IdeS Subunits Using the X500B QTOF System
Isotopic Resolution of Chromatographically Separated IdeS Subunits Using the X500B QTOF System Fan Zhang 2, Sean McCarthy 1 1 SCIEX, MA, USA, 2 SCIEX, CA USA Analysis of protein subunits using high resolution
More informationCharged Surface Hybrid C18 for High Resolution LC and LC/MS Peptide Separations
Charged Surface Hybrid C18 for High Resolution LC and LC/MS Peptide Separations Higher Quality Peptide Separations Using Hybrid Particle-Based Reversed-Phase Columns and CSH Technology 2013 Waters Corporation
More informationApplication Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore, India
Quantitation of Oxidation Sites on a Monoclonal Antibody Using an Agilent 1260 Infinity HPLC-Chip/MS System Coupled to an Accurate-Mass 6520 Q-TOF LC/MS Application Note Authors Ravindra Gudihal Agilent
More informationImproving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B
Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B Stephan Meding, Aran Paulus, and Remco Swart ¹Thermo Fisher Scientific, Germering,
More informationXevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids
Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids Ian Edwards, Jayne Kirk, and Joanne Williams Waters Corporation, Manchester,
More informationHow discovery activities can influence metabolic profiling in the regulatory space? C. DELATOUR EBF, 25 th September 2015
How discovery activities can influence metabolic profiling in the regulatory space? C. DELATOUR EBF, 25 th September 2015 Outline 2 ן Background - Objectives - Shift in Workflow - Metabolite in safety
More informationSupplemental Materials. Manuscript Title: Enhanced Detection of Low-Abundance Host Cell Protein (HCP) Impurities in
S1 Supplemental Materials Manuscript Title: Enhanced Detection of Low-Abundance Host Cell Protein (HCP) Impurities in High-Purity Monoclonal Antibodies Down to 1 ppm using Ion Mobility Mass Spectrometry
More informationThermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development
Thermo Scientific Solutions for Intact-Protein Analysis Better, Faster Decisions for Biotherapeutic Development Quickly and Accurately Assess Product Quality and Safety Therapeutic proteins and monoclonal
More information: presented at ASMS 2015
: presented at ASMS 2015 Enhanced Detection of Host-Cell Proteins in Biotherapeutic Preparations using Preparative Electrophoresis Followed by LC Ion Mobility -MS Chris Boles 1, Brad J. Williams 2, Danny
More informationNew Approaches to Quantitative Proteomics Analysis
New Approaches to Quantitative Proteomics Analysis Chris Hodgkins, Market Development Manager, SCIEX ANZ 2 nd November, 2017 Who is SCIEX? Founded by Dr. Barry French & others: University of Toronto Introduced
More informationCharacterization of a fusion protein under native and denaturing conditions with maxis II
Characterization of a fusion protein under native and denaturing conditions with maxis II Abstract The maxis II UHR-QTOF was used to characterize key attributes of a fusion protein in its native conformation
More informationDried Blood Spot Analysis From The Clinic To The Laboratory
Dried Blood Spot Analysis From The Clinic To The Laboratory Joanne Mather, Pharmaceutical Life Sciences Waters Corporation 211 Waters Corporation 1 From The Clinic To The Lab Blood Spot Sampling First
More informationApplication of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study
Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study Application note Biotherapeutics and Biologics Authors Suresh Babu C.V., Anne
More informationAnalysis of Monoclonal Antibody (mab) Using Agilent 1290 Infinity LC System Coupled to Agilent 6530 Accurate-Mass Quadrupole Time-of-Flight (Q-TOF)
Analysis of Monoclonal Antibody (mab) Using Agilent 9 Infinity LC System Coupled to Agilent Accurate-Mass Quadrupole Time-of-Flight (Q-TOF) Application Note Authors Ravindra Gudihal and Suresh Babu CV
More information[ ACQUITY UPLC system ] Performance so strong it moved the industry forward
[ ACQUITY UPLC system ] ULTRA PERFORMANCE Performance so strong it moved the industry forward And brought the impact of science beyond the bench The proven performance of the ACQUITY UPLC System, used
More informationThe CebE/MsiK Transporter is a Doorway to the Cellooligosaccharide-mediated. Pathogenicity
The CebE/MsiK Transporter is a Doorway to the Cellooligosaccharide-mediated Induction of Streptomyces scabies Pathogenicity Samuel Jourdan, Isolde Maria Francis, Min Jung Kim, Joren Jeico C. Salazar, Sören
More information[ ACQUITY UPLC SYSTEM ] Performance so strong it moved the industry forward
ULTRA PERFORMANCE Performance so strong it moved the industry forward And brought the impact of science beyond the bench The proven performance of the ACQUITY UPLC System, used in thousands of laboratories
More informationAsish Chakraborty, St John Skilton, Weibin Chen and John C. Gebler Waters Corporation, Milford, MA, U.S. INTRODUCTION METHODS. Sample preparation
Com p r e h ensiv e a n d Rou t in e C ha r ac t e riz at io n o f P rot eins a n d P e p t i d e s by LC/MS and LC/MS E Asish Chakraborty, St John Skilton, Weibin Chen and John C. Gebler Waters Corporation,
More informationof peptide mapping chemistries, 130Å or 300Å with tunable UV, photodiode array, or mass spectrometry
UPLC PEPTIDE ANALYSIS SOLUTION UPLC Peptide Analysis Solution: n ACQUITY UPLC System n Peptide Separation Technology chemistries, 130Å or 300Å n Flexible detection capabilities, with tunable UV, photodiode
More informationHongwei Xie, Martin Gilar, and John C. Gebler Waters Corporation, Milford, MA, U.S.A. INTRODUCTION EXPERIMENTAL
Analysis of Deamidation and Oxidation in MONOCLONAL Antibody Using Peptide Mapping with UPLC/MS E Hongwei Xie, Martin Gilar, and John C. Gebler Waters Corporation, Milford, MA, U.S.A. INTRODUCTION Monoclonal
More informationA Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS
Application Note PROTEOMICS METABOLOMICS GENOMICS INFORMATICS GLYILEVALCYSGLUGLNALASERLEUASPARG CYSVALLYSPROLYSPHETYRTHRLEUHISLYS A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery
More informationAnalysis of Intact Monoclonal Antibodies Using an M3 MicroLC with the TripleTOF 6600
Procedures Analysis of Intact Monoclonal Antibodies Using an M3 MicroLC with the TripleTOF 66 Robust and Sensitive Workflow for Qualitative and Quantitative Analysis of Biotherapeutic IgGs Khatereh Motamedchaboki,
More informationCaptiveSpray nanobooster
CaptiveSpray nanobooster The Revolution in Proteomics Ionization Innovation with Integrity LC-MS Source The Key to Performance and Reliability for nano flow MS Bruker CaptiveSpray principle: Stable and
More informationTrastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform
Trastuzumab Glycan Batch-to-Batch Profiling using a UPLC/FLR/Mass Spectrometry Platform Ying Qing Yu, Joomi Ahn, and Martin Gilar Waters Corporation, Milford, MA, U.S. APPLICATION BENEFITS Used together,
More informationIntroduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications
SWATH Acquisition Improves Metabolite Coverage over Traditional Data Dependent Techniques for Untargeted Metabolomics A Data Independent Acquisition Technique Employed on the TripleTOF 6600 System Zuzana
More informationE f f ic i ent ly Com pa ring Bat c h e s o f a n Intac t Mono c lo na l A n t ibo dy using t h e
E f f ic i ent ly Com pa ring Bat c h e s o f a n Intac t Mono c lo na l A n t ibo dy using t h e BioPharmaLynx Software Package Scott J. Berger and Weibin Chen Waters Corporation, Milford, MA, U.S.A INTRODUCTION
More informationRapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS
Rapidly Characterize Antibody- Drug Conjugates and Derive Drug-to-Antibody Ratios Using LC/MS Ning Tang, Ph.D. Agilent Technologies Santa Clara, California, USA Heterogeneity in ADCs Complexity T-DM1 (Genentech)
More informationThe Role of Chemistry Consumables in Biopharmaceutical Product Development
Technology & Services The Role of Chemistry Consumables in Biopharmaceutical Product Development a report by John C Gebler, Jeff R Mazzeo and William J Warren Director, Life Sciences Reasearch and Development,
More informationTabisam Khan 1, David R. Little 1, Liyu Yang 2, Jiwen Chen 2, Parya Nouri 2, Samy Tadros 2, Patrick J. Rudewicz 2
AIMS High throughput bioanalysis plays a central role in the drug discovery and development process. The resulting data are used to determine a drug candidate's pharmacokinetic parameters that are crucial
More informationApplication Note. Authors. Abstract. Ravindra Gudihal Agilent Technologies India Pvt. Ltd. Bangalore India
Characterization of bacteriophage derived anti-staphylococcal protein (P28) from production to purification using Agilent HPLC-Chip Q-TOF LC/MS system Application Note Authors Ravindra Gudihal Agilent
More informationEASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime
EASY-Spray Columns Guidance for column set up and installation Tips to maximize column lifetime EASY-Spray Column Tips and Tricks This document provides guidance for Thermo Scientific EASY-Spray column
More informationNext Generation Technology for Reproducible and Precise Proteome Profiling
7 th Czech Mass Spectrometry Conference April 11th, 2018 Next Generation Technology for Reproducible and Precise Proteome Profiling Lars Kristensen, Ph.D. Application and training specialist The world
More informationNano LC at 20 nl/min Made Easy: A Splitless Pump Combined with Fingertight UHPLC Nano Column to Boost LC-MS Sensitivity in Proteomics
Nano LC at 20 nl/min Made Easy: A Splitless Pump Combined with Fingertight UHPLC Nano Column to Boost LC-MS Sensitivity in Proteomics Rieux L 1., De Pra M 1., Köcher T 2., Mechtler K 2., Swart R 1 1 Thermo
More informationParallel LC with Capillary PS-DVB Monolithic Columns for High-Throughput Proteomics
Parallel LC with Capillary PS-DVB Monolithic Columns for High-Throughput Proteomics INTRODUCTION Peptide sequencing by nano LC-ESI-MS/MS is a widespread technique used for protein identification in proteomics.
More informationFast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles
Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles Application Note Biotherapeutics and Biosimilars Authors James Martosella, Alex
More informationMicroflow Liquid Chromatography Mass Spectrometry System. Nexera Mikros C146-E350
Microflow Liquid Chromatography Mass Spectrometry System Nexera Mikros C146-E35 Micro: Above and Beyond Nano The High Sensitivity You Expect from a Low Flow System with the Ruggedness of HPLC Covering
More informationExpand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017
Expand Your Research with Metabolomics and Proteomics Christine Miller Omics Market Manager ASMS 2017 New Additions to Agilent Omics Workflows Acquisition Ion Mobility Q-TOF IM All Ions MS/MS Find Features
More informationH-Class & H-Class Bio AutoBlend and AutoBlend plus. Jean-Michel Plankeele May Waters Corporation 1
H-Class & H-Class Bio AutoBlend and AutoBlend plus Jean-Michel Plankeele May 2012 2012 Waters Corporation 1 UPLC H-Class Introduction in 2010 What Were The Requests? More flexibility? More solvent capability
More informationA Generic 2D-UPLC/MS Assay for the Identification and Quantification of Host Cell Proteins in Biopharmaceuticals
A Generic 2D-UPLC/MS Assay for the Identification and Quantification of Host Cell Proteins in Biopharmaceuticals Catalin Doneanu, Keith Fadgen, StJohn Skilton, Martha Stapels, and Weibin Chen Waters Corporation,
More informationApplication Note. Kwasi Antwi, Amanda Ribar, Urban A. Kiernan, and Eric E. Niederkofler Thermo Fisher Scientific, Tempe, Arizona
Analysis of an Antibody Drug Conjugate using MSIA D.A.R.T. S. Technology, an Integral Part of Ligand Binding Mass Spectrometric Immunoassay (LB-MSIA) Workflow Application Note Kwasi Antwi, Amanda Ribar,
More informationION EXCHANGE KIT FOR MAB SEPARATIONS
ION EXCHANGE KIT FOR MAB SEPARATIONS Sepax Technologies, Inc. 5 Innovation Way Newark, Delaware, USA Tel: (32) 366-111 Fax: (32) 366-1151 Toll free: www.sepax-tech.com Content Introduction... 1 Technical
More informationPESTICIDE SCREENING APPLICATION SOLUTION
PESTICIDE SCREENING APPLICATION SOLUTION The most innovative pesticide screening solution ever built for food, beverage, and water testing. As the global food trade continues to expand, so does the challenge
More informationSimultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis
Simultaneous in vivo Quantification and Metabolite Identification of Plasma Samples Using High Resolution QTof and Routine MS E Data Analysis Mark Wrona, 1 Paul Rainville, 1 Eric Langlois, 2 Nigel Ewing,
More informationRapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution
Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution Rapidly Identify Top Metabolites with the SCIEX X500R QTOF System and MetabolitePilot TM 2.0 Software Shaokun Pang and Ian Moore SCIEX,
More informationPut the PRO in Protein Characterization
Put the PRO in Protein Characterization Aaron Boice LC/Q-TOF Product Manager 5-June-2017 Agenda The Right Tools for the Job Tackling Intact Proteins Break it Down Peptides and PTMs Sweet Success Released
More informationUpdate to USP <621> Chromatography: What does this mean? USP 37 NF 32 1S Current as of August 2014
Update to USP Chromatography: What does this mean? USP 37 NF 32 1S Current as of August 2014 2015 Waters Corporation 1 What is the USP-NF? The United States Pharmacopeia National Formulary (USP-NF)
More informationcolumns PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns
columns PepSwift and ProSwift Capillary Monolithic Reversed-Phase Columns PepSwift and ProSwift monolithic columns are specially designed for high-resolution LC/MS analysis in protein identification, biomarker
More informationSeparation of Native Monoclonal Antibodies and Identification of Charge Variants:
Separation of Native Monoclonal Antibodies and Identification of Charge Variants: Teamwork of the Agilent 31 OFFGEL Fractionator, Agilent 21 Bioanalyzer and Agilent LC/MS Systems Application Note Biosimilar
More informationMassPREP On-Line Desalting Cartridge
CONTENTS I. INTRODUCTION II. INSTALLING THE MASSPREP ON-LINE DESALTING CARTRIDGE INTO THE SENTRY.1 X 1 MM GUARD COLUMN HOLDER III. RECOMMENDED LC/MS SYSTEM CONFIGURATION TO MINIMIZE MS SOURCE CONTAMINATION
More informationTargeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry INTRODUCTION
Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry Lauren Mullin, 1 Xavier Ortiz Almirall, 2 Stuart Oehrle, 1 and Adam Ladak 1 1 Waters Corporation,
More informationMass Detection for the Chromatographer Waters ACQUITY QDa Detector
Mass Detection for the Chromatographer Waters ACQUITY QDa Detector Warren B Potts III Senior Director Americas Marketing warren_potts@waters.com 2017 Waters Corporation 1 Agenda Overview of technology
More informationApplicationNOTE THE USE OF A NANOLOCKSPRAY ELECTROSPRAY INTERFACE FOR EXACT MASS PROTEOMICS STUDIES
OVERVIEW This application note describes the implementation of a dual sprayer NanoLockSpray TM source on the Waters Micromass Q-Tof micro TM mass spectrometer This source consists of a dual sprayer arrangement;
More informationImproved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental
Improved SPE for UPLC/MS Determination of Diquat and Paraquat in Environmental Samples Michael S.Young, Jeremy C. Shia, Kim vantran, Kevin M. Jenkins and Masayo Yabo Waters Corporation 34 Maple Street,
More informationQuantitative Analysis of pesticides including Phenoxy-acids in surface and drinking water matrices using UPLC-ON-LINE-SPE-MS/MS
Quantitative Analysis of pesticides including Phenoxy-acids in surface and drinking water matrices using UPLC-ON-LINE-SPE-MS/MS Alexandre Paccou Demo Centers and Application Support Manager, Southern Europe
More informationtimstof Pro with PASEF and Evosep One: Maximizing throughput, robustness and analytical depth for shotgun proteomics
timstof Pro with PASEF and Evosep One: Maximizing throughput, robustness and analytical depth for shotgun proteomics The timstof Pro powered by PASEF enables sequencing speed of > 2 Hz, high sensitivity
More informationApplication Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins
Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins BioPharma Compass TM is a fully automated solution for the rapid characterization
More informationFaster, easier, flexible proteomics solutions
Agilent HPLC-Chip LC/MS Faster, easier, flexible proteomics solutions Our measure is your success. products applications soft ware services Phospho- Anaysis Intact Glycan & Glycoprotein Agilent s HPLC-Chip
More informationApplication Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany
D-LC/MS Characterization of Charge Variants Using Ion Exchange and Reversed-Phase Chromatography Multiple Heart-Cutting D-LC Analysis of Innovator versus Biosimilar Monoclonal Antibodies Application Note
More informationPhi29 Scaffold Has a Helix-Loop-Helix Motif and a Disordered Tail. Marc C Morais et al., Nature Structural Biology 2003
Phi29 Scaffold Has a Helix-Loop-Helix Motif and a Disordered Tail Marc C Morais et al., Nature Structural Biology 2003 Free scaffold 13+ 10 min 3 min 1 min 40 sec 100 % 0 100 % 0 100 % 0 100 % 0 Partially
More informationPrecise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF
Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF Application Note Author David L. Wong Agilent Technologies, Inc. Santa Clara, CA, USA Introduction Monoclonal
More informationRapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution
Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution Rapidly Identify Major Catabolites with the SCIEX X500R QTOF System and MetabolitePilot TM 2.0 Software Ian Moore and Jinal Patel
More informationImproving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS
Improving Sensitivity in Bioanalysis using Trap-and-Elute MicroLC-MS Using the SCIEX M3 MicroLC system for Increased Sensitivity in Antibody Quantitation Remco van Soest and Lei Xiong SCIEX, Redwood City,
More informationEoin F.J. Cosgrave, Matthew A. Lauber, Robert Birdsall, and Sean M. McCarthy Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION
New Capabilities for Monitoring Released N-Glycans through the Combined Use of RapiFluor-MS Labeling, ACQUITY UPLC H-Class Bio System, and Serial Fluorescence/ACQUITY QDa Mass Detection Eoin F.J. Cosgrave,
More informationTwo-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow
Technical Note Two-Dimensional LC Protein Separation on Monolithic Columns in a Fully Automated Workflow Introduction The complex nature of proteomics samples requires high-resolution separation methods
More informationReproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns
Reproducible LC/MS Peptide Separation Using Agilent AdvanceBio Peptide Plus Columns Application Note Biotherapeutics and Biosimilars Author Suresh Babu C.V. Agilent Technologies Inc. Introduction Peptide
More information