Pressure - Process pressure

Size: px
Start display at page:

Download "Pressure - Process pressure"

Transcription

1 Pressure Process ressure Pressure - Process ressure Overview 126 VEGABAR 14, VEGABAR VEGABAR 52, 53, Accessory 140 Dimensions 142 AL-EN - 125

2 Pressure Process ressure VEGABAR 10/40/50: VEGABAR series 10/40/50 ressure transmitters are develoed for rocess ressure measurement of liquids, gases and abrasive roducts. Alication-otimised housings and materials ensure the universal use even under arduous conditions. The main oint are the small rocess fittings from ½ to 1. In addition, VEGABAR series 50 ressure transmitters offer maximum adjustment and indication comfort. VEGABAR 42 ressure transmitters are suitable for easy rocess ressure measurement. Easy adjustment, terminal connection and otional dislay characterise this instrument. VEGABAR 14 and VEGABAR 17 ressure transmitters comlete the range for standard alications. Deending on the alication, you can choose between intrinsically safe, highly overload resistant, flush instruments or versions for high ressure measuring ranges. Ceramic-caacitive measuring cells Measuring range bar dry measuring cell very high overload resistance very good abrasion resistance Piezoresistive measuring cell Measuring range bar flush diahragm elastomer-free small rocess fittings Thin film DMS measuring cell Measuring range bar welded measuring cell high long-term stability dry measuring cell AL-EN

3 Pressure Process ressure Overview VEGABAR 14 VEGABAR 17 VEGABAR 42 Measuring cell: CERTEC Piezoresistive/thin film-dms CERTEC high overload resistance flush high overload resistance Measuring range: bar bar bar Deviation in characteristics: Alication: engineering engineering rocess ressure measurements of gases, vaours and liquids Relacement for: VEGABAR 15 VEGABAR 40 VEGABAR 52 VEGABAR 53 VEGABAR 54 Measuring cell: CERTEC Piezoresistive/thin film-dms CERTEC high overload resistance flush measuring cell ossible high overload resistance Measuring range: bar bar bar Deviation in characteristics: Alication: measurement of gases, vaours measurement of gases, vaours measurement of abrasive and liquids in and viscous liquids and viscous liquids ielines u to 600 bar Relacement for: VEGABAR 40/D80 AL-EN - 127

4 Pressure Process ressure VEGABAR 14 VEGABAR 14 Process ressure transmitter with CERTEC Suitable for ressure measurements of gases, vaours and liquids - dry, ceramic-caacitive sensor element mA two-wire system with a suly voltage of V DC - characteristic deviation 0.5% - long-term stability 0.1%/2 years AL-EN

5 Pressure Process ressure VEGABAR 14 (continuation) Aroval.X without....z Ex Zone2... Pressure/Measuring range 1S Gauge ressure/ bar( kpa)... 1T Gauge ressure/ bar( kpa)... 1U Gauge ressure/ bar( kpa)... 1V Gauge ressure/ bar( kpa)... 1A Gauge ressure/0...1 bar( kpa)... 1B Gauge ressure/ bar( kpa)... 1C Gauge ressure/ bar( kpa)... 1D Gauge ressure/0...4 bar( kpa)... 1E Gauge ressure/0...6 bar( kpa)... 1F Gauge ressure/ bar( kpa)... 1G Gauge ressure/ bar( kpa)... 1H Gauge ressure/ bar( kpa)... 1I Gauge ressure/ bar( kpa)... 1J Gauge ressure/ bar( kpa)... 3T Gauge ressure/ bar( kpa)... 3U Gauge ressure/ bar( kpa)... 3A Gauge ressure/ bar( kpa)... 3B Gauge ressure/ bar( kpa)... 3W Gauge ressure/ bar( kpa)... 3C Gauge ressure/ bar( kpa)... 3D Gauge ressure/ bar( kpa)... 3E Gauge ressure/ bar( kpa)... 3F Gauge ressure/ bar( kpa)... 3G Gauge ressure/ bar( kpa)... 2A Abs.ressure/0...1 bar(0..100kpa)... 2B Abs.ressure/ bar( kpa)... 2C Abs.ressure/ bar( kpa)... 2D Abs.ressure/0...4 bar( kpa)... 2E Abs.ressure/0...6 bar( kpa)... 2F Abs.ressure/ bar( kpa)... 2G Abs.ressure/ bar( kpa)... Electrical connection/protection A1 4-ole lug connection DIN43650-A PG9/IP65... C1 Direct cable outlet with 5 m cable/ip67... M1 Circular lug conn.,4-ole w.screwed lug M12x1/IP65... Process connection/material GV G½A,manometer connec. EN837 PN60 /316Ti... GP G½A inner G¼A PN60/316Ti... GN ½NPT inner ¼NPT PN60/316Ti... GB M20x1,5 manometer connection EN837 PN60/316Ti... Seal measuring cell 1 Viton... 3 EPDM... BAR14 Customer-secific factory setting on request Further rocess fittings and otions on request AL-EN - 129

6 Pressure Process ressure VEGABAR 17 VEGABAR 17 Process ressure transmitter with metal sensor Suitable for ressure measurements of gases, vaours and liquids - two-wire system ma with a ower suly of V DC - characteristic deviation 0.5% Aroval Z without... G Shi aroval... A ATEX II 1/2G, 2G EEx ia IIC T6... D ATEX II 1/2G, 2G EEx ia IIC T6+ATEX II 1/2D IP6X T+M1 1)... S ATEX II 1/2G, EEx ia IIC T6 + Shi aroval... Process connection 84L Thread G1B, hygienic/316ti, max.25 bar/viton 2)... 84B Thread G1B, hygienic/316ti, max.25 bar/epdm 2) Thread G1B,flush/316Ti w.o-ring, u to 1.6bar/NBR... 85L Thread G1B,flush/316Ti w.o-ring, u to 1.6bar/Vit... 85B Thread G1B,flush/316Ti w.o-ring,u to 1.6bar/EPDM Thread G½B,flush/316Ti w. o-ring, >1,6 bar/nbr... 86L Thread G½B,flush/316Ti w. o-ring, >1.6 bar/viton... 86B Thread G½B,flush/316Ti w.o-ring, >1.6 bar/epdm... GBX G¼B manometer connection/316ti... GDX G½B,manometer connection/316ti... NBX Thread ¼NPT/316Ti... NDX Thread ½NPT/316Ti... Pressure B Gauge ressure... S Absolute ressure 3)... Continuation see next age AL-EN

7 Pressure Process ressure VEGABAR 17 (continuation) Measuring range LA bar( kpa)... KA bar( kpa)... GA bar( kpa)... FA bar( kpa)... DA bar( kpa)... CA bar( kpa)... AL bar( kpa)... AM bar( kpa)... AN bar( kpa)... BB bar( kpa)... BC bar( kpa)... BD bar( kpa)... BE bar( kpa)... BF bar( kpa)... BG bar( kpa)... BH bar( kpa)... BI bar( kpa)... BK bar( kpa)... BL bar( kpa)... BM bar( kpa)... BN bar( kpa)... BO bar( kpa)... BP bar( kpa)... BQ bar( kpa)... BS bar( kpa)... BT bar( kpa)... Electrical connection/protection A4 Angle lug connector DIN43650/IP65... M4 Circular lug connector, 4-ole w. screwed lug M12x1... DL Cable outlet/ip67... DM Cable outlet/ip68... FW Terminal housing 316L, lastic cable cland/ip67... FV Terminal housing 316L, stainless steel cable cland/ip67... Cable length Z without... C 1.5 m... E 3 m... G 5 m... I 10 m... Features/Cleaning rocedure Z without... E oil and grease-free... A oil and grease free for oxygen alications 4)... G Fill fluid and materials suitable for foodstuffs... Temerature range A C (standard roduct temerature)... B C (roduct temerature)... C C (roduct temerature, with cooling element)... U C (ambient temerature with EEx ia) 5)... Test certificate Z no... 1 yes 6)... BR17. 1) only with Electrical Connection/Protection "DM" 2) Only with temerature range " C " 3) Only for measuring ranges bar u to bar 4) Medium temerature max. 60 C 5) See EC tye aroval certificate 6) Price and delivery time on request Suitable welded sockets see age 141 Customer-secific factory setting on request AL-EN - 131

8 Pressure Process ressure VEGABAR 42 VEGABAR 42 Process ressure transmitter with inner CERTEC Suitable for ressure measurements of gases, vaours and liquids - characteristic deviation 0.2% - dry, ceramic-caacitive sensor element - adjustable zero oint/san - shock-resistant PBT lastic housing/ rotection IP AL-EN

9 Pressure Process ressure VEGABAR 42 (continuation) Aroval XX without... XM Shi aroval... CX ATEX II 1G, 1/2G, 2G EEx ia IIC T6... CA ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG... CM ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + Shi aroval... Process connection/material GV G½A,manometer connection EN837 PN160/316L... GP G½A inner G¼A PN160/316L... GN ½NPT inner ¼NPT PN160/316L... Seal measuring cell 1 Viton... 2 Kalrez EPDM... Pressure/Measuring range K rel./ bar (-5...5kPa)... L rel./ bar ( kPa)... M rel./ bar ( kPa)... O rel./ bar ( kPa)... P rel./ bar ( kPa)... Q rel./ bar ( kPa)... R rel./ bar ( kPa)... S rel./ bar ( kPa)... T rel./ bar ( kPa)... W rel./ bar ( kPa)... A rel./ bar (0...10kPa)... B rel./ bar (0...20kPa)... C rel./ bar (0...40kPa)... D rel./ bar ( kPa)... E rel./ bar ( kPa)... F rel./ bar ( kPa)... G rel./ bar ( kPa)... H rel./ bar ( kPa)... U rel./ bar ( kPa)... 1 abs./ bar ( kPa)... 2 abs./ bar ( kPa)... 3 abs./ bar ( kPa)... 4 abs./ bar ( kPa)... 5 abs./ bar ( kPa)... Electronic version Z mA... H mA HART... Indication X without... A mounted... BR42. Customer-secific factory setting on request Further rocess fittings and otions on request AL-EN - 133

10 Pressure Process ressure VEGABAR 52 VEGABAR 52 Pressure transmitter with inner CERTEC Suitable for ressure measurements of gases, vaours and liquids - extremely overload resistant - characteristic deviation 0.075% - dry, ceramic-caacitive sensor element - longterm stability 0.1%/2 years - dry adjustment via PLICSCOM - instrument from the lics family Aroval XX without... XM Shi aroval... CX ATEX II 1G, 1/2G, 2G EEx ia IIC T6... CA ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG... CM ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + Shi aroval... DX ATEX II 1/2G, 2G EEx d ia IIC T6 1)... Continuation see next age AL-EN

11 Pressure Process ressure VEGABAR 52 (continuation) Process connection/material GV G½A,manometer connec. EN837 PN160/316L... GT G½A,manometer connect. PN160, axially sealing /316L... GC G½A,manometer connec./hastelloy... GP G½A inner G¼A PN160/316L... GS G½A inner G¼A PN10/PVDF... GN ½NPT inner ¼NPT PN160/316L... GB M20x1.5 manometer connection EN837 PN160/316L... Seal measuring cell 1 Viton... 2 Kalrez EPDM... Pressure/Measuring range K rel./ bar (-5...5kPa)... L rel./ bar ( kPa)... M rel./ bar ( kPa)... O rel./ bar ( kPa)... P rel./ bar ( kPa)... Q rel./ bar ( kPa)... R rel./ bar ( kPa)... S rel./ bar ( kPa)... H rel./ bar ( kPa)... V rel./ bar ( kPa)... A rel./ bar (0...10kPa)... B rel./ bar (0...20kPa)... C rel./ bar (0...40kPa)... D rel./ bar ( kPa)... E rel./ bar ( kPa)... F rel./ bar ( kPa)... G rel./ bar ( kPa)... T rel./ bar ( kPa)... W rel./ bar ( kPa)... 1 abs./ bar ( kPa)... 2 abs./ bar ( kPa)... 3 abs./ bar ( kPa)... 4 abs./ bar ( kPa)... 5 abs./ bar ( kPa)... Electronics H mA HART... P Profibus PA... F Foundation Fieldbus... Housing/Protection K Plastic/IP66/IP67... A Aluminium/IP66/IP67... D Aluminium double chamber/ip66/ip67... V Stainless steel 316L/IP66/IP67... Cable entry/plug connection M M20x1.5/without... N ½NPT/without... Indication-adjustment module (PLICSCOM) X without... A to mounted... BR52. 1) Only in conjunction with housing version "D" Further rocess fittings and otions on request Customer-secific factory setting free of charge AL-EN - 135

12 Pressure Process ressure VEGABAR 53 VEGABAR 53 Pressure transmitter with metal sensor Suitable for ressure measurements of gases, vaours and liquids - characteristic deviation 0.15% - alication-otimised instrument design - rocess fitting acc. to EN837 or flush acc. to ISO228 - dry adjustment via PLICSCOM - instrument from the lics family AL-EN

13 Pressure Process ressure VEGABAR 53 (continuation) Aroval XX without... XM Shi aroval... CX ATEX II 1G, 1/2G, 2G EEx ia IIC T6... CM ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + Shi aroval... DX ATEX II 1/2G, 2G EEx d ia IIC T6 1)... Process connection/material GV G½A,manometer connection/316ti... GF G½A,flush/316Ti with O-ring from 2.5 bar... GC G1A, flush/316ti w. O-ring u to 1.6bar... Seal 1 Viton 2)... 3 EPDM 2)... 4 NBR 2)... X without... Pressure/Measuring range C rel./ bar (0...40kPa)... D rel./ bar ( kPa)... O rel./ bar ( kPa)... P rel./ bar ( kPa)... Q rel./ bar ( kPa)... U rel./ bar ( kPa)... W rel./ bar ( kPa)... X rel./ bar ( kPa)... Z rel./ bar ( kPa)... 1 abs./ bar ( kPa)... 2 abs./ bar ( kPa)... 3 abs./ bar ( kPa)... 4 abs./ bar ( kPa)... Electronics H mA HART... P Profibus PA... F Foundation Fieldbus... Housing/Protection K Plastic/IP66/IP67... A Aluminium/IP66/IP67... D Aluminium double chamber/ip66/ip67... V Stainless steel 316L/IP66/IP67... Cable entry/plug connection M M20x1.5/without... N ½NPT/without... Indication-adjustment module (PLICSCOM) X without... A to mounted... BR53. 1) Only in conjunction with housing version "D" 2) Only with flush version Further rocess fittings and otions on request Customer-secific factory setting free of charge Suitable welded sockets see age 141 AL-EN - 137

14 Pressure Process ressure VEGABAR 54 VEGABAR 54 Pressure transmitter with flush CERTEC For level and ressure measurement in aer, water and waste water - characteristic deviation 0.1% - dry, ceramic-caacitive sensor element - abrasion-resistant by CERTEC - highly overload resistant - instrument from the lics family Aroval XX without... XM Shi aroval... CX ATEX II 1G, 1/2G, 2G EEx ia IIC T6... CA ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG... CM ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + Shi aroval... DX ATEX II 1/2G, 2G EEx d ia IIC T6 1)... Process connection/material GB Thread G½A flush PN60/316L... GA Thread G¾A comletely flush PN60/316L... GC Thread G1A comletely flush PN60/316L... VP Thread G1A for PASVE PN40/316L... Continuation see next age AL-EN

15 Pressure Process ressure VEGABAR 54 (continuation) Seal measuring cell 1 Viton... 2 Kalrez EPDM... Pressure/Measuring range K rel./ bar (-5...5kPa)... L rel./ bar ( kPa)... M rel./ bar ( kPa)... O rel./ bar ( kPa)... P rel./ bar ( kPa)... Q rel./ bar ( kPa)... R rel./ bar ( kPa)... S rel./ bar ( kPa)... T rel./ bar ( kPa)... W rel./ bar ( kPa)... A rel./ bar (0...10kPa)... B rel./ bar (0...20kPa)... C rel./ bar (0...40kPa)... D rel./ bar ( kPa)... E rel./ bar ( kPa)... F rel./ bar ( kPa)... G rel./ bar ( kPa)... T rel./ bar ( kPa)... V rel./ bar ( kPa)... 1 abs./ bar ( kPa)... 2 abs./ bar ( kPa)... 3 abs./ bar ( kPa)... 4 abs./ bar ( kPa)... 5 abs./ bar ( kPa)... 7 abs./ bar ( kPa)... Electronics H mA HART... P Profibus PA... F Foundation Fieldbus... Housing/Protection K Plastic/IP66/IP67... A Aluminium/IP66/IP67... D Aluminium double chamber/ip66/ip67... V Stainless steel 316L/IP66/IP67... T PE-cable axial IP68, ext. housing lastic IP65 2)... U PE-cable axial IP68, ext. housing 316L IP65 2)... Cable entry/plug connection M M20x1.5/without... N ½NPT/without... Indication-adjustment module (PLICSCOM) X without... A to mounted... BR54. 1) Only in conjunction with housing version "D" 2) 6 m PE-cable with caillaries incl. wall and rail mounting set Cable length in m er additional 100 mm PE cable Further rocess fittings and otions on request Customer-secific factory setting free of charge AL-EN - 139

16 Pressure Process ressure Accessory Blocking valve form A with tension sleeve G ½ - stainless steel... Article no steel... Article no ø 63 Manometer conection tube Quadrant ie 90 ; with connection G½A and tension sleeve - stainless steel... Article no Sihon in U-Form for horizontal ressure extraction with connection G½A and tension sleeve - stainless steel... Article no steel... Article no Sihon in circular form for vertical ressure extraction with connection G½A and tension sleeve G ½ - stainless steel... Article no steel... Article no ø G ½ ø 6 79 G ½ G ½ 3 20 ø ø 6 2, G ½ G ½ ø 6 56 G ½ AL-EN

17 Pressure Process ressure Accessory Measuring instrument holder for wall-tube mounting 1) - stainless steel... Article no. BARMONT.A M6 ca ø 40 1) for VEGABAR 42, 52 and 53 Fixing screw Welded socket for VEGABAR 17 and VEGABAR 53 - suitable for rocess fitting G½B/316 L... Article no mm (53/64") 10,5mm (13/32") G 1/2 ø 30mm (1 3/ 16") ø 18,2mm ( 23/ 32") Welded socket for VEGABAR 17 and VEGABAR 53 - suitable for rocess fitting G1B/316 L... Article no mm (53/64") 10,5mm (13/32") G 1 ø 30,1mm (1 3/ 16") ø 50mm (1 31/ 32") Welded socket for VEGABAR 17 and VEGABAR 53 - suitable for rocess fitting G1B flush; hygienic/316 L... Article no ,5mm (1") 12,5mm (31/64") G 1 ø 29,3mm (1 5/ 32") ø 50mm (1 31/ 32") AL-EN - 141

18 Pressure Process ressure Dimensions VEGABAR 14 49,5mm (1 61/64") 36mm (1 27/ 64") 25mm (63/64") 45mm (1 3/ 4") 153mm (6 1/32") 36mm (1 27/64") SW27 ø 38mm (1 1/ 2") G½A 124mm (4 7/8") 31mm (1 7/32") G½A G1/ 4 25mm (63/64") 5mm (13/64") ø 3mm (1/ 8") ø 6mm (1/ 4") 20mm (25/32") 3mm (1/8") ø 17,5mm (11/ 16") GV GP M12x1 132mm (5 13/64") 10mm (25/64") ½"NPT 1/ 4"NPT 36mm (1 27/64") M20x1,5 36mm (1 27/64") 25mm (63/64") 15mm (19/32") 20mm (25/32") 25mm ( /64") 5mm (13/ ") ø 3mm (1/ 8") ø 6mm (1/ 4") GN GB AL-EN

19 Pressure Process ressure Dimensions VEGABAR 17 ~ 135 (~155*) ø 27 ~ 126 (~146*) SW41 ~ 126 (~146*) SW ~ , ~ 123 (~143*) /84L/84B 851/85L/85B 861/86L/86B ~ 116 (~136*) ~ 116 (~136*) ø 5 G1/4B ø ø 6 1/4NPT 1/2NPT GBX GDX NBX NDX 1 Cooling element G½B 2 Cooling element G1B 3 Plug acc. to DIN 43650A 4 Cable outlet 5 Plug M12x1 AL-EN - 143

20 Pressure Process ressure Dimensions Plastic housing 1 85mm (3 11/ 32") 2 76mm (2 63/ 64") 72mm (2 53/64") M20x1,5 82mm (3 15/64") 3 VEGABAR 42 85mm (3 11/32") M20x1,5 160mm (6 19/64") 170mm (6 11/16") SW27 165mm (6 1/2") 155mm (6 7/64") G½A G½A G1/4 25mm (63/64") 5mm (13/64") GV/GI/GB 1) ø 3mm (1/8") ø 6mm (1/4") 20mm (25/32") 3mm (1/8") GP ø 17,5mm (11/16") 160mm (6 19/64") 170mm (6 11/16") 1 without dislay 2 with dislay 3 Ground connection 25mm (63/64") ½ 20mm (25/32") GN 4 15mm ( /32") AL-EN

21 Pressure Process ressure Dimensions Housings ~ 69 ~ 69 ø 77 ~ 87 (96) ø 84 ~ 116 M16x1,5 112 (*123) 117 (*128) 120 (*129) ½ ½ ½ NPT 116 (*125) 20x1,5 M20x1,5/ ½ NPT VEGABAR GV/GC ø 3 ø 6 G ½ A 3 G ø G ½ A GP/GL/GK 20 2 G GS 17 17,5 ½ A Plastic housing (* dimension with integrated PLICSCOM) 2 Stainless steel housing (* dimension with integrated PLICSCOM) 3 Aluminium double chamber housing (* dimension with integrated PLICSCOM) 4 Aluminium housing (* dimension with integrated PLICSCOM) ø 6 G A ½" NPT 3 ø 6 GI GN GB AL-EN - 145

22 Pressure Process ressure Dimensions VEGABAR SW ø 3 ø 6 G A ,5 10 /2B GV GF GC ¼ GN ½" NPT AL-EN

23 Pressure Process ressure Dimensions VEGABAR 54 SW36 SW27 SW41 44mm (1 47/64") G ¾ A 45mm (1 49/64") G ½A 44mm (1 47/64") G 1A 22mm (55/64") ø 23,8mm (15/ 16") ø (1 / 64") 20,8mm (13/16") ø 18,4mm (23/ 32") ø 21mm (53/64") GA GB GC ø 30mm (1 3/ 16") ø 40mm (1 37/ 64") SW36 104,8mm (4 1/8") 30mm (1 3/16") G1" VP ø 31 ø 32 AL-EN - 147

24 Pressure Process ressure Dimensions AL-EN

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240 Technical Information TI 179C/07/en Flow Assembly for ph and Redox Sensors FlowFit P CPA 40 ph flow assembly for demanding processes with high requirements. Sensor holder with three electrode mounting

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Magnetic float switch For vertical installation Model FLS for nuclear power plants Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost

More information

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS GUIDED WAVE RADAR LEVEL INSTRUMENTS DESCRIPTION The microwaves impulses at high frequency travel through a stainless steel guide and they are reflected on the surface of the fluid to analyze. The period

More information

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max Flap Flow Meter for Liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h... All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : 0.1-1 l/h... 20-200 l/h water 5 - Nl/h... 600-6000 Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection:

More information

Immersion Assembly for ph and Redox Sensors DipFit P CPA 140

Immersion Assembly for ph and Redox Sensors DipFit P CPA 140 Technical Information TI 178C/07/en No. 5008898 Immersion Assembly for ph and Redox Sensors DipFit P CPA 10 Immersion assembly with flange connection for demanding processes. Sensor holder with bayonet

More information

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet TRICOR Series Coriolis Mass Flow Meters Technical Datasheet TRICOR - Coriolis Mass Flow Meters Description The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The MAG is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. Benefits Wide range of sizes: DN 15 to DN 2000 (½ to 78 ) The flexible design

More information

Thermocouple for Flue Gas Temperature Measurements,

Thermocouple for Flue Gas Temperature Measurements, Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and

More information

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Diaphragm seal with flange connection With internal diaphragm, threaded design Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,

More information

Accessories for Sample Gas Probe GAS 222

Accessories for Sample Gas Probe GAS 222 Accessories for Sample Gas Probe GAS 222 Sample tubes Downstream filters Capacitive vessel In-situ filters Cal gas connections Pneumatic actuators Extensions Adapter flanges 3/2-way-solenoid valves Blowback

More information

Over pressure Switching pressure difference (typical) Lower range Upper range

Over pressure Switching pressure difference (typical) Lower range Upper range Allfluid pressure switches electromechanical actuated -... 63 bar, G/2 For Ex zones and 2 (gases) as well as Ex zones 2 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold

More information

Flow Rate Transmitters/ Flow Switches

Flow Rate Transmitters/ Flow Switches Flow Rate ransmitters/ Flow Switches FOw RAE RANSMIERS FOw SwICHES o measure the flow rate in machines and systems HYDAC EECRONIC offers various fl ow rate transmitters and fl ow switches. he fl ow rate

More information

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma Thermocouple Thermometers Ignition Protection Exd measuring monitoring analysing TTL-Exd T2 O O Measuring ranges: max. 1100 C OO NiCr-Ni or Fe-CuNi thermocouples OO Output: sensor or analogue 4-20 ma O

More information

Measuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600

Measuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600 Bypass Level Indicators ATEX or GL Approval measuring monitoring analysing NBK -ATEX,-GL -03, -06, -07, -10 Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart Pressure: max.

More information

12 Temperature measurement SCT analogue

12 Temperature measurement SCT analogue 12 Temperature measurement SCT analogue Temperature measurement SCT analogue High-pressure-resistant temperature sensors For measuring temperatures up to 1,000 C Flexible operation Inline or probe-type

More information

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE C20 C21 C26-2 C26-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420. Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

Visionary Sensor Technology CDG045D. High Precision Vacuum Gauge. True pressure measurement

Visionary Sensor Technology CDG045D. High Precision Vacuum Gauge. True pressure measurement Visionary Sensor Technology CDG045D High Precision Vacuum Gauge True ressure measurement CDG045D Vacuum Gauge The INFICON temerature controlled CDG Caacitance Diahragm Gauge line is designed for the highest

More information

Omnigrad M TR47, TR48

Omnigrad M TR47, TR48 Technical Information Omnigrad M TR47, TR48 Hygienic, modular RTD assembly for weld-in installation Various process connections and fast response time Application All hygienic applications for food, pharmaceutical

More information

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

SPRING LOADED THERMOCOUPLE CONFIGURATIONS SPRING LOADED THERMOCOUPLE CONFIGURATIONS FOR USE WITH THERMOWELLS II 3G Ex na/nl TCRN/WN/TN S30 S31 S36-1 S36-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration guarantees

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview Configuration is a guided wave radar transmitter for short and medium range level, level/interface and volume measurement of liquids and solids. It is unaffected by changes in process conditions,

More information

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid

More information

O O Pressure: max. PN 100 / Class 600. O O Temperature: -40 C C (ceramic rollers) 0 C C (PP-rollers)

O O Pressure: max. PN 100 / Class 600. O O Temperature: -40 C C (ceramic rollers) 0 C C (PP-rollers) ypass Level Indicators ATEX or GL Approval measuring monitoring analysing NK -ATEX,-GL -03, -06, -07, -10 O O Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart O O Pressure:

More information

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. CATALOG Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. APPLICATIONS Monitoring of the flow of concentrate and recirculation of a reverse osmosis water treatment plant Reverse Osmosis System Water

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 May 2009 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

Turbimax CUS51D. Technical Information

Turbimax CUS51D. Technical Information Technical Information Turbimax CUS5D Sensor for turbidity and solids content Installation and immersion sensor for low, middle and high turbidity and solids concentrations Application Turbimax CUS5D is

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

Float Flow Meters series NF

Float Flow Meters series NF Float Flow Meters series NF - Quality design - High corrosion resistance - Reliable measurement principle - Low weight and small dimensions Doc. no.: 22, en_cat_nf, 8/2015 Usage Flowmeters type NF are

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet

More information

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures BPG 42 The BPG range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

Visual Level Indicators VLI

Visual Level Indicators VLI WEKA Visual Level Indicators VLI Certified according ISO 9001:2000 Certified according PED 97/23/EC Member of the Group Certified according ATEX 94/9/EC Principles of design Single-pole Magnet System The

More information

High Pressure Filter Assemblies

High Pressure Filter Assemblies High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than

More information

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.

More information

ALUBOX Series Junction boxes in IP66 aluminium alloy

ALUBOX Series Junction boxes in IP66 aluminium alloy UBOX Series Junction boxes in IP aluminium alloy > ENCLOSURES IP UBOX Series UBOX-EX Series Dimensions () Screw for attaching cover Earthing screws Weight (Kg) 00 x 00 x 59 n 2 M5x0 n M4x 0,290 /32 53.00

More information

DIN 3015 CLAMPS B1-1 PN# / / ACC

DIN 3015 CLAMPS B1-1 PN# / / ACC DIN 0 CLAMPS DIN 0 Clamps HYDAC manufactures a complete line of hose, tube, and pipe mounting components according to the DIN 0 standard. HYDAC clamps assure a simple, reliable dampening support for lines

More information

Butterfly valve VZAV

Butterfly valve VZAV Butterfly valve VZAV Content 1 General Information VZAV... 3 2 Order Information VZAV... 4 2.1 Modular System... 4 2.2 Part No. types... 4 3 Type code VZAV... 5 4 Technical Data... 7 4.1 General technical

More information

Level Sensors 1001 Table of contents

Level Sensors 1001 Table of contents Table of contents Index Table of contents 4 Description and function 5 Certificates / Approvals 6-7 Level Sensors 1001 Stainless steel DN10 to DN500 8 Brass DN10 to DN80 9 Titanium DN10 to DN500 10 Alloy

More information

Diaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel

Diaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel Ed.17.01 Design Diaphragm Seal with flush diaphragm and flange acc.to EN 1092-1 or ASME B 16,5 Pressure gauge in stainless steel Type Lower body Flush diaphragm with flange connection acc.to EN 1092-1

More information

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial

More information

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features. VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet 34-VF-03-12 October 2009 Specification The solution for bulk mass flow measurement The VersaFlow Coriolis 200 has been developed to meet

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Technical description Siemens AG 2008 Design Function A resistance thermometer comprises Measuring resistor the measuring resistor (metal; platinum, Pt or nickel, Ni) and Measuring resistors the mounting

More information

Return Line Filter RFM

Return Line Filter RFM Return Line Filter RFM Flow rates up to 85 l/min Pressure range up to 1 bar Material: Aluminium/Steel/Synthetic material Return line filters type RFM are designed to be mounted on tank tops to filter out

More information

DML-Series. Pelton wheel flow meter

DML-Series. Pelton wheel flow meter DML-Series Pelton wheel flow meter Flow meter manufacture As a specialist in flow measurement technology, TrigasDM supplies high-quality measuring instruments, electronics and calibrators for liquids and

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet

TRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet TRICOR Series Coriolis Mass Flow Meters Technical Datasheet TRICOR - Coriolis Mass Flow Meters Description The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors

More information

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86

KEYSTONE SWING TYPE WAFER CHECK VALVE FIGURE 86 High capacity, spring loaded swing type wafer check valve FEATURES Lightweight, wafer type check valve with face-to-face dimensions according ISO 5752, table 5 long High flow capacity featuring a special

More information

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3)

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3) pplication and Type PN pplication for liquids, gases and vapours Ø D 80 BB EN BB SME PN Class 150 suitable for heating, air-conditioning, water supply and cooling installations,for applications where minimum

More information

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid Screw-Type Volumetric Flow Meter for Viscous Media measuring monitoring analysing OM... Measuring ranges: 0.-0... 0-000 l/min liquid OMeasuring O accuracy: ± 0.% of span : 00 ± 0.% of span : 0 p max :

More information

Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E

Sho-Rate TM 50 Model 1350E and Sho-Rate TM 150 Model 1355E Data Sheet Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E Ten-to-one rangeability Heavy-wall, precision bore, borosilicate glass metering tubes A wide range of scales on the metering tube

More information

Model 1159 Remote Diaphragm Seals

Model 1159 Remote Diaphragm Seals 00813-0100-0 English May 1999 Rev. AB 119 Remote Diaphragm Seals with 112, 113 Series B, D and F, and 11 Alphaline Nuclear Pressure Transmitters Product Discontinued 119 Remote Diaphragm Seals Qualified

More information

Mechatronic pressure measurement. Applications. Special features. Description

Mechatronic pressure measurement. Applications. Special features. Description Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data

More information

Wing Union/Hammer Union Pressure Sensors Models 434, 435, Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Wing Union/Hammer Union Pressure Sensors Models 434, 435, Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION Wing Union/Hammer Union Pressure Sensors Models 434, 435, 437 32301963 Issue 3 Datasheet Model 434 with cage not pictured. DESCRIPTION Models 434/435/437 Wing Union/Hammer Union Pressure Sensors are designed

More information

SensoLyt System Design

SensoLyt System Design Sensolyt Sensor Systems Measurement SensoLyt System Design For continuous measurement, especially under the difficult conditions very often found in sewage treatment facilities, very high demands are made

More information

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume Pressure Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.41, large working volume WIKA data sheet DS 99.32 for further approvals see page 7 Applications Aggressive,

More information

Technical Information Orbisint CPS11D and CPS11

Technical Information Orbisint CPS11D and CPS11 TI00028C/07/EN/14.15 71299911 Products Solutions Services Technical Information Orbisint CPS11D and CPS11 ph electrodes, analog or with digital Memosens technology For standard applications in process

More information

Model BF 260 Incubators Avantgarde.Line with forced convection

Model BF 260 Incubators Avantgarde.Line with forced convection Model BF 260 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly

More information

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available

More information

High temperature pressure sensor

High temperature pressure sensor Pressure High temperature pressure sensor for gas turbine- and thermoacoustics applications Differential, acceleration compensated, piezoelectric pressure sensor for operating temperatures up to 700 C.

More information

Fieldbus Systems. Fieldbus System: CC-Link

Fieldbus Systems. Fieldbus System: CC-Link Fieldbus Systems Fieldbus System: CC-Link CC-Link is the most dominant and fastest growing fieldbus technology in Asia. The open network is supported by the global CC-Link partner association CLPA, which

More information

MAGFLO. Flow metering based on electromagnetic technology. For value-adding performance you can count on. FLOW DIVISION Simply Better

MAGFLO. Flow metering based on electromagnetic technology. For value-adding performance you can count on. FLOW DIVISION Simply Better MAGFLO Flow metering based on electromagnetic technology For value-adding performance you can count on FLOW DIVISION Simply Better VALUE-ADDING PERFORMANCE Discover the value-adding advantages of MAGFLO

More information

Thermocouple Thermometer omnigrad M -TC 13

Thermocouple Thermometer omnigrad M -TC 13 Technical Information TI 276T/02/en 60022268 Thermocouple Thermometer omnigrad M TC 13 Replaceable insert and thermowell with flanged process connection PCP (4...20 ma), HART or PROFIBUSPA electronics

More information

Flexdip CYH112. Technical Information. Holder system for water and wastewater assemblies

Flexdip CYH112. Technical Information. Holder system for water and wastewater assemblies Technical Information Flexdip CYH112 Holder system for water and wastewater assemblies pplication Water treatment Wastewater treatment Plant design CYH112 is a modular holder system for sensors and assemblies

More information

Keystone swing type wafer check valve Figure 86

Keystone swing type wafer check valve Figure 86 High capacity, spring loaded swing type wafer check valve Features Lightweight, wafer type check valve with face-to-face dimensions according ISO 5752, table 5 long High flow capacity featuring a special

More information

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 -PERFORMANCE CURVES Performance Curve Best One 200 Performance

More information

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials

THERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials THERMOMETERS Thermometers are used to measure temperature. PIC stocks a variety of temperature measuring instruments, including bimetals, magnetic thermometers, tridicators and scale thermometers. STANDARD

More information

F64G - Olympian Plus Plug-In System General purpose filter

F64G - Olympian Plus Plug-In System General purpose filter > > Port size: /... 3/ (ISO G/PTF) > > Quick release bayonet bowl > > Effective liquid removal and positive solid filtration > > Large filter element area for minimum pressure drop Technical features Medium:

More information

AT9000 Advanced Transmitter Absolute Pressure Transmitters

AT9000 Advanced Transmitter Absolute Pressure Transmitters No. SS2-GTX00A-0500 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

Reference thermometer Model CTP5000

Reference thermometer Model CTP5000 Calibration technology Reference thermometer Model CTP5000 WIKA data sheet CT 61.20 Applications Reference thermometer for measuring very accurate temperature in a range of -196... +660 C [-321... +1,220

More information

Model BF 720 Incubators Avantgarde.Line with forced convection

Model BF 720 Incubators Avantgarde.Line with forced convection Model BF 720 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly

More information

CONA -Universal ANSI / CONA -Connector ANSI

CONA -Universal ANSI / CONA -Connector ANSI CONA -Universal ANSI for quick assembly/disassembly on CONA -Connector or foreign system connectors CONA -Universal ANSI / CONA -Connector ANSI CONA B-Universal ANSI Bimetallic steam trap ANSI CONA M-Universal

More information

WWW.SAMSUNGPJS.CO.KR SAMSUNG Pipe Joint System, is a manufacturing company, specialized in metal stamping, form rolling and pipe extrusion. With more than 20 years of manufactring experience, we are able

More information

Diaphragm seal with flange connection With internal diaphragm Model

Diaphragm seal with flange connection With internal diaphragm Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm Model 990.26 WIKA data sheet DS 99.26 for further approvals see page 7 Applications Aggressive, highly viscous, crystallising

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter The Satam range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals. Consisting of four distinct families, the range is able to meet the needs of most industrial

More information

Expert SUBMERSIBLE LEVEL TRANSMITTERS BROCHURE EN 2.75 EXPERT BROCHURE 1401

Expert SUBMERSIBLE LEVEL TRANSMITTERS BROCHURE EN 2.75 EXPERT BROCHURE 1401 Expert SUBMERSIBLE LEVEL TRANSMITTERS BROCHURE EN 2.75 EXPERT BROCHURE 1401 O U T S T A N D I N G D U R A B I L I T Y A N D H I G H P R E C I S I O N 2 MJK level transmitters are designed for level measurement

More information

LBHF LBHS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K. Ex d IIC U DIP A21

LBHF LBHS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K. Ex d IIC U DIP A21 OPEN BENDS AND PULLING BOXES Explosion Proof Electrical Equipment Ex Conduit fittings Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D

More information

Omnigrad T TST310. Technical Information. RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring

Omnigrad T TST310. Technical Information. RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring Technical Information Omnigrad T TST310 RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring Application The resistance thermometer is specially suited to temperature

More information

min. 50min. 65min. PIT / P3 / P4 Ø

min. 50min. 65min. PIT / P3 / P4 Ø Flush design Stop switch, IP 65 Equipment consisting of (schematic overview) 2 78 23 Actuator Anti-twist ring 2... 6 Pressure ring = Screw terminal Product can differ from the configuration. Bayonet flange

More information

Model B. Thermostatic Control Valves. Typical applications

Model B. Thermostatic Control Valves. Typical applications Thermostatic Control Valves Model B Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications

More information

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications Diaphragm Seals > Diaphragm Seals Diaphragm Seals Diaphragm seals, also referred to as chemical seals, are used to isolate pressure gauges, switches and transmitters from clogging and/or corrosive media.

More information

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Rosemount 1152 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

ZDM POSITIVE DISPLACEMENT FLOW METER

ZDM POSITIVE DISPLACEMENT FLOW METER ZDM POSITIVE DISPLACEMENT FLOW METER Flow Pressure Level Temperature Measurement Monitoring Control Viscosities up to 100,000 cst Accuracy: ±0.3% of Flow To 6500 PSIG Pressure Can Detect Flow Direction

More information