HD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min

Size: px
Start display at page:

Download "HD 152 HD 172 In-line mounting Operating pressure up to 630 bar Nominal flow rate up to 190 l/min"

Transcription

1 High Pressure Filters Worldline HD HD 7 In-line mounting Operating pressure up to bar Nominal flow rate up to 9 l/min Description Application In the high pressure circuits of hydraulic systems. Performance features Protection against wear: By means of filter elements that, in full-flow filtration, meet even the highest demands regarding cleanliness classes. Protection against malfunction: Through installation near to the control valves or other expensive components. The specific determined flow rate guarantees a closed by-pass valve even at ν mm /s (cold start condition). Filter elements Flow direction from outside to centre. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life High Pressure Filter HD 7 Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter life. Materials Filter head: Filter bowl: Coating: Seals: Filter media: Spheroidal graphite cast iron (SGI) Cold extruded steel Powder paint NBR (FPM on request) EXAPOR MAX - inorganic multi-layer microfibre web Paper - cellulose web, impregnated with resin Accessories If an electrical indicator is used a transparent socket with LED for optical indication is also available with Part No. DG.. Subject to change.-e Page

2 Characteristics Operating pressure... bar, min. x pressure cycles Nominal pressure according DIN... bar, min. pressure cycles Quasi-static operating pressure Permissible pressures for other numbers of cycles Operating pressure p [bar] Nominal flow rate Up to 9 l/min (see Selection Chart, column ) The nominal flow rates indicated by ARGO-HYTOS are based on the following features: closed by-pass valve at ν mm /s element service life > operating hours at an average fluid contamination of,7 g per l/min flow volume flow velocity in the connection lines: up to bar 8 m/s > bar m/s Number of cycles n Filter fineness µm(c)... µm(c) β-values according to ISO 889 (see Selection Chart, column and diagram Dx) Dirt-holding capacity Values in g test dust ISO MTD according to ISO 889 (see Selection Chart, column ) Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet.) Temperature range - C... + C (temporary - C... + C ) Viscosity at nominal flow rate at operating temperature: ν < mm /s as starting viscosity: ν max = mm /s at initial operation: The recommended starting viscosity can be read from the diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 7 % p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Mounting position Preferably vertical, filter head on top Connection Threaded ports according to ISO 8 or DIN. Sizes see Selection Chart, column (other port threads on request). Electrical clogging indicator Switching voltage: max. V AC / 7 V DC Switching current: max.,7 A AC /, A DC Switching power: max., VA AC / W DC Type of contact: Change-over Electrical protection: IP (with mounted and secured socket) Page Subject to change.-e

3 Diagrams p-curves for complete filters in Selection Chart, column D flow volume at ν = mm /s ( = casing empty) kinematic viscosity at nominal flow,,, HD,,, 7,,, Q [l/min] ν [mm /s] D flow volume at ν = mm /s ( = casing empty) kinematic viscosity at nominal flow,,, HD 7 7,,, 7,,, Q [l/min] ν [mm /s] Filter fineness curves in Selection Chart, column Dx Filtration ratio β as a function of particle size x obtained by the Multi-Pass Test according to ISO 889 The abbreviations represent the following β-values resp. finenesses: Filtration ratio β for particles > x µm Efficiency [%] For EXAPOR MAX and Paper elements: EX = β (c) = EXAPOR MAX 7EX = β 7 (c) = EXAPOR MAX EX = β (c) = EXAPOR MAX EX = β (c) = EXAPOR MAX P = β (c) = Paper Based on the structure of the filter media of the P paper elements, deviations from the printed curves are quite probable. For screen elements S = screen material with mesh size µm S = screen material with mesh size µm S = screen material with mesh size µm Tolerances for mesh size according to DIN 89 Particle size x [µm] (for particles larger than the given particle size x) For special applications, finenesses differing from these curves are also available by using special composed filter media. Subject to change.-e Page

4 Selection Chart Part No. Nominal flow rate Pressure drop see diagram D/curve no. Filter fineness see diagr. Dx Dirt-holding capacity Connection A/B Cracking pressure of by-pass Symbol Replacement filter element Part No. Weight l/min g bar kg bar Clogging indicator Cracking pressure in ( ) HD -8 D/ EX G¾ - V.7-7, electrical () change-over HD - D/ EX 7 G¾ 7 V.7-,9 - - HD -7 D/ EX 7 G¾ 7 V.7-7, optical () - HD - D/ EX 7 G¾ 7 V.7-7, electrical () change-over Remarks HD -88 D/ EX G - V.7-8 7, electrical () change-over HD -8 7 D/ EX 7 G 7 V.7-8,9 - - HD D/ EX 7 G 7 V.7-8 7, optical () - HD -8 7 D/ EX 7 G 7 V.7-8 7, electrical () change-over HD - D/ P 8,7 G 7 P.7-,9 - - HD - D/ P 8,7 G 7 P.7-7, optical () - HD D/ EX G - V.- 8, electrical () change-over HD 7- D/ EX 7 G 7 V.- 8, - - HD 7-7 D/ EX 7 G 7 V.- 8, optical () - HD 7- D/ EX 7 G 7 V.- 8, electrical () change-over HD 7-8 D/ EX 8 G - V.- 8, electrical () change-over HD 7- D/ EX G 7 V.- 8, - - HD 7-7 D/ EX G 7 V.- 8, optical () - HD 7- D/ EX G 7 V.- 8, electrical () change-over HD D/ EX 9 G - V.-8 8, electrical () change-over HD D/ EX G 7 V.-8 8, - - HD D/ EX G 7 V.-8 8, optical () - HD D/ EX G 7 V.-8 8, electrical () change-over HD 7- D/7 P G 7 P.- 8, - - HD 7- D/7 P G 7 P.- 8, optical () - Filter element differential pressure stable up to bar Paper media supported with metal gauze Remarks: The filters listed in this chart are standard filters. If modifications are required, e.g. connections SAE ¾ resp. SAE ( psi), we kindly ask for your request. If an electrical indicator is used a transparent socket with LED for optical indication is also available with Part No. DG.. Page Subject to change.-e

5 Dimensions Version with integrated optical clogging indicator G P E ØC A B ØC S F Q D E ØH ØR E Version with integrated electrical clogging indicator SAE-flange ( psi) I K S Minimum distance from ferromagnetic parts: 7 mm Q M Terminal connection N O M L M Measurements Type A/B C D E F G H I K L M Ø/depth N O P Q opt./electr. R S opt./electr. HD G¾, G, AF7 M/ 7, 9/8 / HD 7 G AF7 M/ 7, 9/8 / Symbols 7 Subject to change.-e Page

6 Spare Parts 7 Pos. Designation Part No. Filter bowl HD HD. Filter bowl HD 7 HD 7. O-ring x, N7. Filter element see Chart/col. 9 Reed switch with screws and socket (Pos. ) HD 9. Socket DIN - AF DG. Optical indicator (with Pos. 7) HD 9. 7 O-ring 7 x N7.7 The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO-HYTOS can only be guaranteed if original ARGO-HYTOS spare parts are used. Quality Assurance Quality management according to DIN EN ISO 9 To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to the following ISO standards: ISO 9 ISO 9 ISO 9 ISO 98 ISO 889 ISO 8 Verification of collapse/burst pressure rating Verification of fabrication integrity (Bubble Point Test) Verification of material compatibility with fluids Evaluation of pressure drop versus flow characteristics Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity) Determination of resistance to flow fatigue using high viscosity fluid Before release into the series production the filter casing is tested for fatigue strength in our pressure pulse test rig. Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. Page Subject to change.-e

E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min

E 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min Return Filters E 9 E E Tank top mounting Connection up to G Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against

More information

Return Line Filter RFM

Return Line Filter RFM Return Line Filter RFM Flow rates up to 85 l/min Pressure range up to 1 bar Material: Aluminium/Steel/Synthetic material Return line filters type RFM are designed to be mounted on tank tops to filter out

More information

Process Inline Filter, Change-Over

Process Inline Filter, Change-Over Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.

More information

MDF. Pressure Filters MODULAR INLINE FILTER

MDF. Pressure Filters MODULAR INLINE FILTER MDF Pressure Filters MODULAR INLINE FILTER Pressure Filters MDF MDF 3,5 MPa (35 bar) Port sizes: etop 0507 Flow rates: 7 l/min TEHNIAL DATA Max. working pressure: 3,5 MPa (35 bar) Max. test pressure: 40

More information

High Pressure Filter Assemblies

High Pressure Filter Assemblies High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than

More information

KRAL Volumeter - OMG Series Universal Flowmeters

KRAL Volumeter - OMG Series Universal Flowmeters KRAL Volumeter - OMG Series Universal Flowmeters OMG - Universal OMG Flowmeters for a Wide Range of Applications Operating Conditions and Materials Flow Range: 0.03 to 2000 gpm Max. Pressure: 3600 psi

More information

Series description Wilo-Drain STS 40

Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Series description Wilo-Drain STS 40 Subject to change 09/2008 WILO SE Wilo Catalogue C2 - - Sewage pumps from DN 32 to DN 800 Materials Pump housing: EN-GJL-250 Pedestal:

More information

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 CONTENTS -SPECIFICATIONS Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103 -PERFORMANCE CURVES Performance Curve Best One 200 Performance

More information

Flow Rate Transmitters/ Flow Switches

Flow Rate Transmitters/ Flow Switches Flow Rate ransmitters/ Flow Switches FOw RAE RANSMIERS FOw SwICHES o measure the flow rate in machines and systems HYDAC EECRONIC offers various fl ow rate transmitters and fl ow switches. he fl ow rate

More information

Rexroth Oil Cleanliness Booklet

Rexroth Oil Cleanliness Booklet Rexroth Oil Cleanliness Booklet 2 Oil Cleanliness Booklet Introduction Introduction Oil is the central component of any hydraulic system. If a system fails, contamination is one of the major reasons. This

More information

Close Coupled Sump Pumps Type ETLB

Close Coupled Sump Pumps Type ETLB Close Coupled Sump Pumps Type ETLB»dry running safe«technical data Flow rate Q up to 104 m 3 /h Head H up to 36 m Submersion depth up to 775 (795) mm Suction extension up to 1500 mm Materials limits of

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

WILLBRANDT PTFE Expansion Joint Type 80

WILLBRANDT PTFE Expansion Joint Type 80 WILLBRANDT PTFE Expansion Joint Type 0 00 Type 0 is a 3 or corrugated PTFE expansion joint that is hotformed under pressure from extruded PTFE tubing. The fibers are executed without interruption. It is

More information

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. : +200 C OScrew O thread: G ¼... G 4. t max. Rp 1...

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. : +200 C OScrew O thread: G ¼... G 4. t max. Rp 1... Magnetic Filters and Dirt Traps measuring monitoring analysing MFR / MFF / MFT OO p max : PN 40 OO t max : +200 C OScrew O tread: G ¼... G 4 OScrew O tread: Rp 1... Rp 2 OFlanges: O DN 50... DN 200 OSolder

More information

Flanged Water Meters (non-continuous flow)

Flanged Water Meters (non-continuous flow) Flanged Water Meters (non-continuous flow) Features MW-F Suitable for use with domestic water Pulsed output Low head loss Specification Product Codes Meter: Cold water: Fluid temp. range: Cold 0 to 30

More information

The Professional Choice LAC 200. Air oil cooler SIZE MATTERS! OLAER LAC 200 The largest standard air oil cooler in the class

The Professional Choice LAC 200. Air oil cooler SIZE MATTERS! OLAER LAC 200 The largest standard air oil cooler in the class The Professional Choice LAC 200 Air oil cooler SIZE MATTERS! OLAER LAC 200 The largest standard air oil cooler in the class 2 OLAER LAC 200 The Olaer Group is a global player specialising in innovative,

More information

M21Si ISO and M21Vi ISO Reduced Bore Ball Valves DN15 to DN150 Flanged PN40

M21Si ISO and M21Vi ISO Reduced Bore Ball Valves DN15 to DN150 Flanged PN40 Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523 Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523 Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

F64G - Olympian Plus Plug-In System General purpose filter

F64G - Olympian Plus Plug-In System General purpose filter > > Port size: /... 3/ (ISO G/PTF) > > Quick release bayonet bowl > > Effective liquid removal and positive solid filtration > > Large filter element area for minimum pressure drop Technical features Medium:

More information

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 ) PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and

More information

Standard Parts. Ganter. Highlights Standard Parts in Hygienic Design

Standard Parts. Ganter. Highlights Standard Parts in Hygienic Design Standard Parts. Ganter. Highlights Standard Parts in Standard Parts in Maximum hygiene is a fundamental requirement, not only where food is produced. Hygiene also plays an increasing role in other industrial

More information

ZDM POSITIVE DISPLACEMENT FLOW METER

ZDM POSITIVE DISPLACEMENT FLOW METER ZDM POSITIVE DISPLACEMENT FLOW METER Flow Pressure Level Temperature Measurement Monitoring Control Viscosities up to 100,000 cst Accuracy: ±0.3% of Flow To 6500 PSIG Pressure Can Detect Flow Direction

More information

HIGH PERFORMANCE FILTER MEDIA HYDRAULIC AND LUBRICATING SYSTEMS

HIGH PERFORMANCE FILTER MEDIA HYDRAULIC AND LUBRICATING SYSTEMS HIGH PERFORMANCE FILTER MEDIA HYDRAULIC AND LUBRICATING SYSTEMS ISO CLEANLINESS CODES The most widely used method for representing fluid cleanliness is the International Standards Organization (ISO) Code

More information

Filtration for Improved Bearing and Equipment Life Filtration for Improved Bearing and Equipment Life

Filtration for Improved Bearing and Equipment Life Filtration for Improved Bearing and Equipment Life Filtration for Improved Bearing Martin Williamson KEW Engineering Ltd. Bearings can have an infinite life when particles larger than the lubricant film are removed. SKF 2 3 4 Case Studies & Successes Nippon

More information

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN40 : +200 C. Rp1...Rp2. OO p max. OO t max. OO Screw thread: G¼...G4. OO Flanges: DN50...

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN40 : +200 C. Rp1...Rp2. OO p max. OO t max. OO Screw thread: G¼...G4. OO Flanges: DN50... Magnetic Filters and Dirt Traps measuring monitoring analysing MFR / MFF / MFT OO p max : PN40 OO t max : +200 C OO Screw tread: G¼...G4 OO Screw tread: Rp1...Rp2 OO Flanges: DN50...DN200 OO Solder connections:

More information

In-line Twin Pump. Type Series Booklet. Omega DSL

In-line Twin Pump. Type Series Booklet. Omega DSL In-line Twin Pump Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed

More information

Compressed Air Filters 1/4 and 1/2 Line Size Filters

Compressed Air Filters 1/4 and 1/2 Line Size Filters Compressed Air Filters Compressed Air Filters 1/4 and 1/2 Line Size Filters Models A914D, A914P, A914, A914A Models A914P and A914D are 1/4 line size assemblies with simple, reliable automatic drains used

More information

Universal Bottle Sampler

Universal Bottle Sampler 233 Features & Benefits Simple operation Efficient testing procedure Clean and contamination free sampling Available for both mineral based and aggressive fluids Further advances the LCM20 s flexibility

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 203 PERFORMANCE CURVE VOX 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

Regulating valves REG 6-65, REG-SS 15-40

Regulating valves REG 6-65, REG-SS 15-40 MAKING MODERN LIVING POSSIBLE Technical brochure Regulating valves REG 6-65, REG-SS 15-40 REG are angle-way and straight-way regulating valves, which act as normal stop valves in closed position. The valves

More information

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm GB Filterautomat The New Definition of Purity for Your Medium Our Filter Systems Protect The Filterautomat Cooling Water River Water Plate Heat Exchangers Spray Nozzles Sea Water Sinter and Scale Separation

More information

TWIN LASER PARTICLE COUNTER

TWIN LASER PARTICLE COUNTER SERIES 30 TWIN LASER PARTICLE COUNTER Online and inline options available. Complete range of test options. Automatic on-line continuous test facility. Variable time & test programmes. Remote operating

More information

KLINGER Ballostar KHE: This ball valve offers more

KLINGER Ballostar KHE: This ball valve offers more KLINGER Ballostar KHE Split body ball valve DN (1/2 ) 0 ( ) Edition 10 Tel. + (0)2252 600-0 Fax + (0)2252 600- Web: www.klinger.kfc.at KLINGER Ballostar KHE: This ball valve offers more The design of

More information

The Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo

The Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo Filters The Aqua Flo range of filters and replacement cartridges improves water quality in the home, farm or business. Requiring no special tools, Aqua Flo filters are easily installed and cartridge replacement

More information

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST Line Filters 7-0 Solid, simple, smart. Advanced reliability in compressed air. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY PARTNERSHIP SERVICEABILITY

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

Ref RESILIENT SEAT GATE VALVE ISO PN10-16 F4. Model/Ref:

Ref RESILIENT SEAT GATE VALVE ISO PN10-16 F4.  Model/Ref: Model/Ref: 180-181 - 182 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 600 ISO PN10/16 flanges - 10 C + 110 C with EPDM wedge Max Pressure : 16 Bars up to DN400,

More information

Dorot Irrigation Meter

Dorot Irrigation Meter DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features

More information

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops. OPERATING LIMITS Flow rates up to : m /h Heads up to :, m Max. operating pressure : bar Max. loop temperature : +8 C Max. circulator temperature: C Max. ambient temperature : + C Water hardness (TH) :

More information

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS - June 2013 Addendum GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS SUBSECTION "A" : GENERAL RULES SUBSECTION "B" : CLASS 1 COMPONENTS SUBSECTION "C" : CLASS 2 COMPONENTS SUBSECTION "D" : CLASS

More information

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Diaphragm seal with flange connection With internal diaphragm, threaded design Model Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,

More information

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial

More information

50 Hz. TLCN, TLCHN Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS

50 Hz. TLCN, TLCHN Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS 5 Hz TLCN, TLCHN Series WET ROTOR CIRCULATORS FOR SANITARY SYSTEMS Cod. 19171 Rev. B Ed.1/14 TCLN, TLCHN SERIES INSTALLATION POSITIONS Lowara, Xylect are trademarks of Xylem Inc. or one of its subsidiaries.

More information

Filtration Products. Fluid purifier systems and oil service equipment

Filtration Products. Fluid purifier systems and oil service equipment Filtration Products Fluid purifier systems and oil service equipment Eaton combines sales, engineering, manufacturing, customer service and technical sales support into one focused business provide customers

More information

New filter materials for hydraulic systems: Longer service life and reduced operating costs

New filter materials for hydraulic systems: Longer service life and reduced operating costs New filter materials for hydraulic systems: Longer service life and reduced operating costs Bosch Rexroth is introducing a new generation of filter media, using state-of-the-art materials and advanced

More information

The most energy efficient compressed air filters in the world.

The most energy efficient compressed air filters in the world. The most energy efficient compressed air filters in the world www.domnickhunter.com The most en compressed air Don t drive your comp Old filtration technology Ordinary compressed air filters have always

More information

Line filters LINE FILTERS

Line filters LINE FILTERS Line filters LINE FILTERS 45-2430 Worthington Creyssensac s heritage Creyssensac was founded in Nanterre (near Paris), France in 934 by Elie Creyssensac and quickly became renowned in the automotive industry

More information

TDC46M Carbon Steel Thermodynamic Steam Trap with Maintainable Seat

TDC46M Carbon Steel Thermodynamic Steam Trap with Maintainable Seat 2 3 4 7 6 5 8 9 1 Optional extra V1 integral blowdown valve See spare parts for details on how to order; Alternatively please specify at the time of order placement. escription The TC46M is a carbon steel,

More information

Weir Valve Selections

Weir Valve Selections Unlined Metal Excellent Cvs Complete Selection of End Connections ASTM Materials Include: Cast Iron ASTM A-126 Class B Ductile Iron ASTM A-395 Grade 60-40-18 Cast Steel ASTM A-216 Grade WCB 316 Stainless

More information

Over pressure Switching pressure difference (typical) Lower range Upper range

Over pressure Switching pressure difference (typical) Lower range Upper range Allfluid pressure switches electromechanical actuated -... 63 bar, G/2 For Ex zones and 2 (gases) as well as Ex zones 2 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold

More information

Worcester Controls E51/52. Enviro-Safe High Integrity Flanged Ball Valves

Worcester Controls E51/52. Enviro-Safe High Integrity Flanged Ball Valves Worcester Controls E1/2 Enviro-Safe High Integrity Flanged Ball Valves General Description With environmental protection and control established as a major issue for the future, Flowserve Worcester Controls

More information

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling Flygt N-Pumps 3085, 3102 & 3127 For reliable and efficient wastewater handling The Concept Flygt N-Pump series Reduced pumping efficiency, high energy and maintenance costs shouldn t be a fact of life

More information

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. CATALOG Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. APPLICATIONS Monitoring of the flow of concentrate and recirculation of a reverse osmosis water treatment plant Reverse Osmosis System Water

More information

Coating Specifications

Coating Specifications Quadax Series Butterfly Valves Version May 2011 müller co-ax ag Gottfried-Müller-Str. 1 74670 Forchtenberg Germany Tel. +49 7947 828-0 Fax +49 7947 828-11 E-Mail info@co-ax.com Internet www.co-ax.com Table

More information

Water Softener softliq:mc. Intended use. Function. Design

Water Softener softliq:mc. Intended use. Function. Design Subject to modifications TD2-BS000de_004 Edition May 2016 Intended use The water softener softliq:mc may only and exclusively be used for the softening and partial softening of cold drinking water. The

More information

Carbon film resistors

Carbon film resistors Carbon film resistors (6.3 φ 2.4 size: 1 / 3W) ROHM resistors are produced using an integrated production system for parts and materials, and state of the art technology to ensure high precision productivity,

More information

PN 40 DN 25-40, PN 25 DN 50-80, PN 16 DN Ball seal alternatives Stellite (KC) PTFE (TC) Tightness class ISO 5208, EN RATE D RATE A

PN 40 DN 25-40, PN 25 DN 50-80, PN 16 DN Ball seal alternatives Stellite (KC) PTFE (TC) Tightness class ISO 5208, EN RATE D RATE A Operation WAFER PATTERN V-PORT BALL VALVE stainless steel 5, 501 series C ont R o L Description Edition Högfors ball sector valve series 5 is specially designed for control applications of various media

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

Hydraulic Filtration Products PANTONE.pdf 1 09/08/17 18:34 SUCTION FILTERS C M Y CM MY CY CMY K

Hydraulic Filtration Products PANTONE.pdf 1 09/08/17 18:34 SUCTION FILTERS C M Y CM MY CY CMY K SUCTION FILTERS A WORLDWIDE LEADER IN THE FIELD OF HYDRAULIC FILTRATION EQUIPMENT. Our company started life in 9, when Bruno Pasotto decided to attempt to cater for the requests of a market still to be

More information

PETREX -CNT. Pipe systems for petrol stations Technical details

PETREX -CNT. Pipe systems for petrol stations Technical details PETREX - Pipe systems for petrol stations Technical details Contents 1.0 1.0 Contents 1.10 1.100 System description System description PETREX - 1.11 1.11.01 Product overview Piping, connections, fittings

More information

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions process measurement solutions 3 Rotameter Series 3 glass tube variable area flowmeter Data sheet 70 A range of quality glass tube V.A. flowmeters for general purpose & industrial applications Robust construction

More information

BSA3HP Bellows Sealed High Pressure Stop Valve

BSA3HP Bellows Sealed High Pressure Stop Valve Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

PNEUMATIC RACK & PINION ACTUATORS

PNEUMATIC RACK & PINION ACTUATORS PNEUMATIC RACK & PINION ACTUATORS 90-120 - 180 ALPHAIR PNEUMATIC ACTUATORS 90 - STD Series 120 - Y Series 180 - X Series ALPHAIR pneumatic actuators are made by the best manufacture experience on design,

More information

EC medium pressure axial fans.

EC medium pressure axial fans. EC medium pressure axial fans. The efficient system solution. The engineer s choice GreenTech EC technology in a new dimension. Thanks to these new new axial axial fans, fans, our our highly highly efficient

More information

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Magnetic float switch For vertical installation Model FLS for nuclear power plants Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

FLUID CLEANLINESS OIL FILTRATION

FLUID CLEANLINESS OIL FILTRATION FLUID CLEANLINESS c o m p a r i s o n g u i d e Companion Booklet to be used with The Portable Fluid Analysis Kit A Companion Booklet to be used with The Portable Fluid Analysis Kit OIL FILTRATION TM SYSTEMS,

More information

ABEL EM. Electromechanical Membrane Pumps The economical alternative. From the reciprocating positive displacement pump specialist

ABEL EM. Electromechanical Membrane Pumps The economical alternative. From the reciprocating positive displacement pump specialist ABEL EM From the reciprocating positive displacement pump specialist Electromechanical Membrane Pumps The economical alternative 1 Membrane Pumps Solids Handling Pumps High Pressure Pumps Marine Pumps

More information

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3)

DISCOCHECK Dual-Plate Check Valves BB Short overall length according to DIN EN 558-1, table 11, series 16 (=^ DIN 3202, part 3, series K3) pplication and Type PN pplication for liquids, gases and vapours Ø D 80 BB EN BB SME PN Class 150 suitable for heating, air-conditioning, water supply and cooling installations,for applications where minimum

More information

The World s Most Versatile Filter System

The World s Most Versatile Filter System The World s Most Versatile Filter System Full-flow filtration systems By-pass filtration systems Water Based Fluids Process Fluids Heating oils Turbine oils Bioethanol Hippo Filter Biodiesel Kerosene Diesel

More information

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.

More information

Hydraulic Fluid Contamination and Assessment. Fluid Power Engineering Technology Instructor Hennepin Technical College

Hydraulic Fluid Contamination and Assessment. Fluid Power Engineering Technology Instructor Hennepin Technical College Hydraulic Fluid Contamination and Assessment Presented by: Ernie Parker Fluid Power Engineering Technology Instructor Hennepin Technical College 1 About 95% of all hydraulic problems are cause by heat,

More information

Pneumatic control and on/off valves for thermoelectric plants

Pneumatic control and on/off valves for thermoelectric plants BASIC REQUIREMENTS FOR QUALIFYING SUPPLY AND CONTRACTING COMPANIES Equipment category : FMVA11 Pneumatic control and on/off valves for thermoelectric plants Technical characteristics Page 1 of 8 CONTENTS

More information

Monolithic Isolation Fittings

Monolithic Isolation Fittings Monolithic Isolation Fittings The Industry s Dual O Ring Seal Standard Tests Include: 100% Hydrostatic Pressure & Electrical Tests 100% Ultrasonic of Welds 100% Magnetic Particle of Welds 100% Dye Penetrant

More information

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505

YARWAY HANCOCK CONTINUOUS BLOWDOWN GLOBE VALVE SERIES 5505 Advanced construction features of this high pressure drop angle globe valve provide quality and long service life. FEATURES GENERAL APPLICATION In addition to continuous blowdown service, the Yarway high

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 50 to 600 Flanges R.F. PN10/16-10 C + 120 C Max Pressure : 16 Bars up to DN300 ( 10 bars over ) Specifications : Ductile iron disc All positions Low

More information

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8 and 1/4 NPT. Features. Construction. Electrical ANSI Accredited Program PRODUCT CERTIFICATION 4 Direct Acting Subminiature Solenoid Valves /8" and /4" NPT / 856 -WAY Features -way normally closed operation Compact design Brass and 6 stainless steel

More information

Improved Water Quality in the Home

Improved Water Quality in the Home Improved Water Quality in the Home Aqua Flo Point-of-Use 69 Aqua Flo Point-of -Use Water Filters Novo offers a wide range of point-of-use filtration solutions. Aqua Flo Economy - A full line of quality

More information

Liquid level switch BW 17

Liquid level switch BW 17 KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

Mechatronic pressure measurement. Applications. Special features. Description

Mechatronic pressure measurement. Applications. Special features. Description Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data

More information

Energy & Data Transmission Systems for Underground Applications

Energy & Data Transmission Systems for Underground Applications Energy & Data Transmission Systems for Underground Applications Systems for Underground Applications Conductix-Wampfler energy & data transmission systems keep tunnels moving forward. Whether it s for

More information

CONA -Universal ANSI / CONA -Connector ANSI

CONA -Universal ANSI / CONA -Connector ANSI CONA -Universal ANSI for quick assembly/disassembly on CONA -Connector or foreign system connectors CONA -Universal ANSI / CONA -Connector ANSI CONA B-Universal ANSI Bimetallic steam trap ANSI CONA M-Universal

More information

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment

More information

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES: SERIES 4624B (Cast Iron - Replaces Series 4625 Models) Page 410.1 Issue K SERIES DESCRIPTION The Abrasive Liquid Series heavy duty internal gear pumps utilize hard parts in key wear areas, combined with

More information

Betapure Rigid. Filter Media Filters & Capsules. 3M Filtration CUNO Division

Betapure Rigid. Filter Media Filters & Capsules. 3M Filtration CUNO Division 3M Filtration CUNO Division Betapure Rigid Filter Media Filters & Capsules The Betapure Filter Advantage Precise Contaminant Removal Improved Effluent Quality Reduced Operating Costs Betapure Designed

More information

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420. Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ

More information

DIN EN : (E)

DIN EN : (E) DIN EN 13445-3:2013-12 (E) Unfired pressure vessels - Part 3: Design Contents Page Foreword... 6 1 Scope... 7 2 Normative references... 7 3 Terms and definitions... 8 4 Symbols and abbreviations... 10

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240 Technical Information TI 179C/07/en Flow Assembly for ph and Redox Sensors FlowFit P CPA 40 ph flow assembly for demanding processes with high requirements. Sensor holder with three electrode mounting

More information

SpeedExtractor E-916 / E-914 Technical data sheet

SpeedExtractor E-916 / E-914 Technical data sheet SpeedExtractor E-916 / E-914 Technical data sheet The SpeedExtractor E-916 / E-914 is an automated instrument for parallel extraction of primarily organic compounds from a variety of solid or semi-solid

More information

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b PIH HTP070b The HTP070 purifier permits treatment of the oil in a power transformer, while on-line and on-load. Application Areas The PALL HTP070 oil purifier removes water, solid particles, air and other

More information

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1 Turbine Meter PTF Wide flow range up to :1 Intrinsically Safe and Flameproof versions available increases range of applications Excellent linearity and repeatability meets fiscal metering standards Linear

More information