1 1 Preface 2 General Instructions 2.1 Application range 2.2 Warnings contained in the operating instruction 2.3 Notes on deliveries 2.4 Transport and storage 2.5 Warranty notes 2.6 Notes on return deliveries 3 Safety 3.1 Proper use 3.2 Qualifi ed personnel 4 Technical description 4.1 Components of the measuring device 4.2 Mode of functioning of the Corrosion Detector Portable 4.3 Properties of the measuring device 4.6 Application limits 4.7 Menu structure 4.8 Operating concept 4.9 Starting up 4.10 Measurement 5 Replacing the batteries 6 Technical data of the Corrosion Detector Portable 7 Note Operating Instructions e

2 1 Preface The present Operating Instructions are designed to familiarize users with the equipment of the Corrosion Detector Portable and its use. The operating instructions (OI) should be accessible to the operating and maintenance personnel in order to ensure that all necessary information is available for using the device. By knowing these OI, you can avoid damage to the measuring equipment and prevent incorrect operation. The information contained in the operating instructions corresponds to the state of the art at the time it is printed and is provided to the best of our knowledge. We reserve the right to include any improvements, amendments and new developments in the operating instructions without prior notice. The actual design of products may differ from the information provided in the catalog if warranted by technical modifi - cations resulting from product improvements. The proposal submitted by Pfaudler for a concrete application will be binding in this case. The latest edition will always supersede all previous ones. The present operating instructions are made available to our customers and interested parties free of charge. Reprints and copies as well as transformation into electronic forms, in whole or in part, shall require our written approval. All rights reserved. 2 General instructions 2.1 Application range The Corrosion Detector Portable is used to inspect glass lined vessels and their internal parts for damages and the resulting metal corrosion. Reactors and internal parts with other insulating coatings (e.g., plastic material or rubber) may also be checked for corrosion of metals using this device. 2.2 Warnings contained in the operating instructions In the operating instructions, the danger symbol is used to draw your attention to especially important safety instructions. Compliance with these instructions is mandatory, because adherence to the instructions can avoid serious mistakes. 2.3 Notes on deliveries The respective scope of delivery is specifi ed on the shipping documents attached to the shipment and corresponds to the valid purchase agreement. Check that the items delivered are complete and intact. 2.4 Transport and storage The Corrosion Detector Portable should be exclusively transported and stored in its closed original case. In order to ensure an as-new condition of the device and accessories, the following storage conditions should be maintained: dry and dust-free steady temperature and ventilation 2.5 Warranty notes Any warranty claims shall not be extended or limited by the information contained in the present operating instructions. For the exact warranty conditions, please refer to the Terms of Sale of Pfaudler Werke GmbH as amended. All warranty claims will be void if the unit is opened. 2.6 Notes on return deliveries Before sending used immersion probes to Pfaudler Werke GmbH or third parties for repair or other purposes, all parts must be cleaned and decontaminated. To protect our staff and for insurance reasons, your return shipment must be accompanied by a clearance certifi cate on which you confi rm that the immersion probes were properly cleaned and decontaminated. You may obtain a form sheet for this purpose from us on request. 2 Pfaudler Werke GmbH

3 3 Safety For detailed safety instructions and information concerning explosion protection, please refer to the end of the operating instructions. 3.1 Proper use Any use of the equipment for purposes other than described in the present operating instructions will adversely affect the safety and functioning of the measuring device and is therefore not allowed. It is important to note the safety instructions applicable to the electrical systems and equipment and all explosion protection provisions, if any. 3.2 Qualifi ed personnel The unit may only be operated by authorized technical personnel in strict compliance with the present operating instructions as well as the valid standards and provisions. The failure to observe these instructions no matter whether intentionally or negligently releases Pfaudler Werke GmbH from all liability and warranty claims. 4 Technical description 4.1 Components of the measuring device Check the items delivered for completeness. The following items are included in the delivery: Hard-sided case with molded insert taking up the measuring device Corrosion Detector Portable including batteries Immersion probe and reference electrode Grounding clamp with contact monitoring Reference electrode (spare) File for cleaning contacts Operating Instructions 4.2 Mode of functioning of the Corrosion Detector Portable If metal gets in contact with a conductive liquid (electrolyte), the result is a voltaic cell. That means that a voltage is generated at the contact surface between the metal and the electrolyte. The value of the voltage is subject to the type of the metal and the chemical properties of the electrolyte. If the voltage exceeds a certain value, metal ions are dissolved, i.e. the metal is corroded. In other words, the metal is decomposed. The voltage value as of which a certain metal is decomposed (corroded) is referred to as the decomposition voltage. Since the corrosion resistance depends on the type of metal, the decomposition voltage also differs between metals. As a result, each metal is characterized by its own specifi c decomposition process (corrosion) which can be electrically distinguished from that of other metals. The measuring device with the Corrosion Detector Portable as the central element works with AC voltage, thus avoiding electrochemical reactions at the measuring electrodes. The measuring loop consists of 4 electrodes the 2 measuring electrodes, the reference electrode and the reactor wall as the 4 th electrode. Pfaudler Werke GmbH 3

4 4.3 Properties of the measuring device The device works according to the principle of impedance analysis. That means: The Corrosion Detector Portable will output an alarm only if metal corrosion has actually occurred on the reactor or the internal parts. Compared to conventional glass monitoring equipment which works according to the principle of conductivity analysis, this method offers fundamental advantages. Conventional systems are not capable of distinguishing between a real alarm and a false alarm when an alarm is signaled. A real alarm is present if the coat is strongly damaged, resulting in a conductive link between the product and the metal (and thus the equipotential bonding system). Such a damage will always be accompanied by corrosion in the damaged spot. A false alarm is defi ned as a conductive link between the product and the equipotential bonding system that is not caused by glass damage. Such links to other plant sections not resistant to corrosion may be the result of production-specifi c operating conditions, e.g., condensate bridges built up via the reactor s nozzles, or when fi lling or draining the reactor. Conductive plant components made of tantalum, titanium, Hastelloy C4, graphite, conductive gaskets or repair plugs made of noble metals do not trigger off a corrosion alarm. 4.4 Construction of the immersion probe The body of the immersion probe is made of PTFE, the highly fl exible, shielded cable with a length of 10 m is insulated with an acid-resistant silicone coat. In the upper part of the probe, the two corrosion-resistant measuring electrodes have been arranged at a 180 offset. The exchangeable reference electrode has been screwed into the lower part, which is closed by a bulgy PTFE plug that prevents contact between the reference electrode made of steel and the glass. Resistors have been integrated into the immersion probe that enable the unit to check whether contact has been made with all electrodes through the cable prior to each measurement as soon as the probe is connected. 4.5 Function of the grounding clamp The grounding clamp is connected to the device through a silicone-insulated cable 3 m in length. Special stainless steel contacts have been integrated into the clamp which enable the unit to monitor the cable and the positive contact with the reactor or potential bonding system. 4.6 Application limits Inappropriate products Solvents, acetic acid, products or water with insuffi cient conductivity. Aggressive media with insuffi cient conductivity, such as bromine or hydrogen bromide. Chemical resistance of the immersion probe The silicone cable and the measuring electrodes are not suitable for permanent use, however, they are resistant to corrosion during short measurements in acids at room temperature. The exchangeable reference electrode is not resistant to corrosion, therefore, it is subject to varying degrees of attack, depending on the acid. If erosion has reached the O-ring seal, the reference electrode must be renewed. 4 Pfaudler Werke GmbH

5 4.7 Menu structure Initial start-up ON Start-up ON Select language Date/Time Owner Corrosion Detector Menu User Test Conductivity calc. Archive Setup Select user New record Edit User name Company:. Name:... Select test location New record Edit location Company:... Bldg: Reactor:.. Prepare measurement Grounding clamp: connect Immersion probe: connect Conductivity calc. Calculate conductivity of approx. 1 ms Conductivity calculator Material : HCL 37% Reactor vol.: 1.0m³ Required 1.08 kg quantity: 0.72L Measurements archive Select measurement Entry XYZ Company/Bldg./Reactor Date/Time Measured result Note Setup System status Set time Language selection LCD contrast Owner Corrosion limit Select Prepare measurement Grounding clamp: Immersion probe: Test Prepare test Grounding clamp: Immersion probe: Conductivity too low HCL (hydrochloric acid) H2SO4 (sulphuric acid) CH2O2 (formic acid) NaCl (common salt) KCL (potassium chloride) Status Firmware:. Battery:... mv... % Wait short time until electrodes have been reconditioned, then repeat measurement Test running 300 sec remaining Test not possible - Add acid Test finished No corrosion Save test? No Yes Archive Test running Aborted Test finished Save test? Yes No Test finished Locate spot? No Yes Add salt and/or acid Press 0 key to turn the OE and KW measured values on or off Status Memory allocation User:... Locations:.. Measured data:... Set time Date: Time Select language German English LCD contrast + / - Locate spot 44 sec No corrosion Finished Locate spot 44 sec Finished Enter owner Text:.. Corrosion limit Factory setting -20 Range: 0 to -160mV Figure 1 Corrosion Detector Portable Pfaudler Werke GmbH 5

6 4.8 Operating concept The relevant softkey function is shown on the display Press to select menu items or to confi rm inputs Delete key for input errors Press arrow or cursor keys to move the cursor is used to abort an activity or to return to the main menu step by step Immersion probe (red) The sockets and connectors are marked by different colors Figure 2 Connection and Keyboard Grounding clamp (green) 4.9 Starting up When starting up the unit for the fi rst time, you are requested to enter the language, date/time and the new owner, e.g. Pfaudler (refer to 4.9.5, Owner). (The owner s name can be changed whenever necessary in the SETUP menu) 4.10 Measurement User: The user may enter his name in the main menu, a max. of 50 users are possible. This entry is made once, whenever the unit is used again, the relevant user may select his name from the list. Corrosion Detector User:.dler/Tabert Test Conductivity calculator Archive Setup :00:00 Press ON to turn the unit on or activate the display's light Press 0 to display measured values or to insert a blank when making entries Test: Do not select Test unless the reactor is ready for the measurement. The Select test location menu is displayed. Select New record if no measurements have been stored in the archive yet. If a reactor has been tested before, it may be selected, and a new record and index no. is generated by pressing Copy. Select test location <New record> Chemical\G22\R12345 Chemical\G22\R12361 Pfaudler\G98\R12379 Pfaudler\G99\R9988 Copy Edit Corrosion Detector I = 444 µa f = 10 Hz OE = 265 mv d = 350 KW = 616 mv UBAT = 4236 mv 18:19:20 Keys for entering numbers or letters Press OFF to turn the unit off When New record has been selected, the Edit location window appears where the company, building and reactor names can be entered, for example. The Reactor line is mandatory. Edit location Company: Chemical Bldg: G22 Reactor: R12345 A/a ABC A/1 Up to 500 locations can be stored. 6 Pfaudler Werke GmbH

7 Once this data has been entered and confi rmed, you will be requested to connect the grounding clamp and the immersion probe. Prepare measurement Chemical\G22\R12345 Grounding clamp: CONNECT!! Immersion probe: CONNECT!! Connect the grounding clamp to the equipotential bonding system or a bare conductor at the reactor; will be displayed if the clamp has been properly connected. Immerse the probe down to the bottom of the reactor. Attention! Previously turn off the agitator. Start measurement. Prepare measurement Chemical\G22\R12345 Grounding clamp: Immersion probe: MEASURE When the measurement has been started, the system checks whether the conductivity and the acid value of the reactor contents or the product are suffi cient for the measurement. If the corrosion potential is too low, the message Test not possible Add acid will be displayed after a short while. Add the OE and KW measured values by pressing the 0 key. Test running When the display appears green, the message Test fi nished, No corrosion. will be displayed. Select No to repeat the measurement and restart the process, or save the values by hitting Yes. Test fi nished No corrosion Save test? No 300 s remaining OE = 265 mv KW = 616 mv Cancel Yes Up to 10,000 measurements can be stored (circulating). When the display appears red, the message Test fi nished,. will be displayed. Select No to repeat the measurement and restart the process, or save the values by hitting Yes. Test fi nished Save test? No Test fi nished Locate spot? No Yes After saving, the display will show Locate spot? You now have the opportunity to locate the corroded spot inside the reactor. If Yes is selected, the display starts fl ashing. Locate spot Yes Empty the reactor in batches; there is no longer any contact if the display fl ashes green. Attention! Make sure that the immersion probe does not get stuck in the bottom valve. 44 s Finished Pfaudler Werke GmbH 7

8 Conductivity calculator If water is used for testing the reactor, the conductivity or acid value fi rst has to be set to approx. 1 ms in order to obtain a reliable measurement Archive All measurements are stored in the archive. When the measurement has been completed, additional information can be input under Note Setup The following settings and controls can be entered in the Setup menu. Setup Conductivity calculator Calculate conductivity of approx. 1mS Measurements archive :34 <> :11 <Corros.> :00 <Corros.> :22 Text :34 <Corros.> System status Set time Language selection LCD contrast Owner 08:00:00 Setup The most common acids and salts have been stored under the Materials option of the calculator. For the acids, you can set a percentage and then enter the reactor volume in m 3. The necessary quantity is indicated in kilos, and additionally in liters for the acid. Conductivity calculator Material: HCl 37 % Reactor vol: 1.0 m3 Select desired measurement and make the desired entries using the Edit option of the Note menu. Entry 1/19 Chemical\G22\R :11:11 <Note> Edit Set time Language selection LCD contrast Owner Corrosion limit 08:00:00 Required quantity: 1.08 kg 0.72 L Entry 1/19 Chemical\G22\R :11:11 Damage in bottom area Edit Only the measurements performed by the active user will be displayed in the archive. 8 Pfaudler Werke GmbH

9 System status: Software version, battery voltage display, capacity and memory allocation. Status Firmware: Batterie: 4319 mv 81% Language selection: Currently, German and English are available. Language selection Deutsch English Français Italiano Español Corrosion limit: The factory setting is 20 mv, and 0 mv would be even more sensitive. If materials are used that are characterized by slight corrosion under normal conditions already, the sensitivity can be reduced to 160 mv in several steps. Corrosion limit Status Memory allocation: User: 3 of 50 Locations: 35 of 500 Meas. results: 52 of (circulating) Set time: Date and time input. LCD contrast: Individual contrast setting adjustment. LCD contrast >>> +2 <<< >>> +1 <<< >>> 0 <<< >>> 1 <<< >>> 2 <<< Default 0 mv 20 mv 40 mv 60 mv Default If the alarm threshold is changed, the proper functioning of the unit should be verifi ed by simulating a damage. Set time Owner: A new name can be entered here if the owner changes :00:00 Enter owner tt.mm Text A/a ABC A/1 Pfaudler Werke GmbH 9

10 5 Replacing the batteries Open the battery compartment on the back of the unit and replace the batteries. Figure 3 Backside Corrosion Detector 6 Technische Daten Corrosion Detector Portabel Power supply: Current input: Minimum conductivity: Measuring voltage: Measuring current: Measuring frequency: 4,5 VDC max. 60 ma 0,8 ms/cm 3,3 Vpp max. 1,7 ma 10 Hz Memory: Owner: 1 entry User: 50 entries Locations: 500 entries Measurements: 10,000 entries (circulating) Working temperature range: 10 C to +50 C Storage temperature: Housing: LxWxH: Weight: 25 C to +80 C (without batteries) Vestamid / black (antistatic) 180 x 85/62 x 30/25,5 mm 271 g Degree of protection: IP 66 Sealed keypad 21 keys (shielded) Compartment for 3 batteries size R6 (with special catch to EN requirement 9.2) Permitted batteries to IEC: LR6 or R6 Permitted rechargeable batteries: Type R6 or RS6 Ansmann, R6 or SR6 Saft, 601RS or 751RS Varta, P60AA or P750AA Panasonic Graphic display 128 x 64 and acryl glass cover (metalized) Connectors for the immersion probe and grounding clamp on face side of enclosure Electromagnetic compatibility (to IEC 801) CE mark 7 Note The Corrosion Detector Portable is equipped with an USB port, the hardware and software for documenting the measurements is in preparation. In its present condition, the unit has been prepared for approval for potentially hazardous atmospheres. Figure 4 Battery compartment open 10 Pfaudler Werke GmbH

11 Pfaudler Werke GmbH 11

12 The information provided in this documentation corresponds to the state of the art at the time of printing. It is published in good faith. However, we will accept no warranty claims based on the information provided in this documentation. We reserve the right to include improvements, amendments and new fi ndings in this documentation without prior notice. The actual design of products may deviate from the information contained in the calatoge if technical alterations and product improvements so require. The proposal made by Pfaudler for a concrete application will be binding in such cases. The present documentation is made available free of charge to our customers and other interested parties. The right to print or copy this documentation, or any parts thereof, or to convert the same into electronic form shall be subject to our written permission. All rights reserved by us e xc by Robbins & Myers, Inc. Printed in Germany Pfaudler Werke GmbH Postfach 1780 D Schwetzingen Pfaudlerstraße D Schwetzingen Telefon Telefax service@pfaudler.de

Dual Port isolated USB Charger

Dual Port isolated USB Charger User & Installation Manual EN Dual Port isolated USB Charger 3A R-net cable P010-61 3A DX cable P010-62 Contact & Product mo-vis BVBA Biebuyckstraat 15 D 9850 Nevele - Belgium Website: www.mo-vis.com E-mail:

More information

HOBO Plug Load Logger (UX ) Manual

HOBO Plug Load Logger (UX ) Manual HOBO Plug Load Logger (UX120-018) Manual The HOBO Plug Load logger is designed to monitor energy consumption of AC-powered plug in loads. This compact device can be used as a power meter with its built-in

More information

Instruction Manual Pocket scale

Instruction Manual Pocket scale KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Instruction Manual Pocket scale KERN TAB Version 1.1

More information

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual P/N 1000006053 Rev E $7%$QDO\WLFV// //& 733 Dairy Rd. Parkton, Md. 21120 www.atbanalytics.com (410) 733-6365 Table of Contents Chapter 1: Getting

More information

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. For more information, visit www.247technology.com/on-line-ups/c60-standby-ups C60 Standby UPS 800VA Models User & Installation Manual 2015. All rights reserved. (Rev 6/23/15) Table of Contents Package

More information

DeskDECT Feature Phone

DeskDECT Feature Phone DeskDECT Feature Phone Please read this manual carefully before using your DeskDECT. 1. 2. 2.1 2.2 INTRODUCTION -------------------------------------------------- GETTING STARTED ---------------------------------------------

More information

Thermocouples. Operating and Maintenance Manual English. Thermocouples

Thermocouples. Operating and Maintenance Manual English. Thermocouples Thermocouples Operating and Maintenance Manual English Seite 1 / 8 Operating and Maintenance Manual Thermocouples Table of Contents 1 General Information 3 2 Functionality 4 2.1 Thermo Lines and Compensating

More information

Inscale Measurement Technology Ltd Tel: Fax:

Inscale Measurement Technology Ltd Tel: Fax: TCC SERIES Inscale Measurement Technology Ltd 7 Heron Close, St. Leonards-on-Sea. East Sussex TN38 8DX United Kingdom Tel: +44(0)1424 200722 Fax: +44(0)1424 443976 Email: sales@inscale-scales.co.uk Http:www.inscale-scales.co.uk

More information

Instruction Manual HI Portable ph/ec/tds/ C Meters

Instruction Manual HI Portable ph/ec/tds/ C Meters Instruction Manual HI 9811-5 Portable ph/ec/tds/ C Meters www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the meter.

More information

64C Amplification Block. Instruction Manual

64C Amplification Block. Instruction Manual 64C Amplification Block Instruction Manual Caution: All rights reserved. Quidel Corporation reserves the right to modify this manual at any time without notice. Any part of the manual shall not be duplicated,

More information

User Manual QProg Lite

User Manual QProg Lite User Manual QProg Lite Dear valued customer! On behalf of our company we wish to welcome you to the QUORiON family of fine business machines. We sincerely hope you will appreciate the many benefits of

More information

Compact flue gas analyser: testo 300 M-I

Compact flue gas analyser: testo 300 M-I 220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial

More information

Load cells Type: RTB Safety Instructions

Load cells Type: RTB Safety Instructions Load cells Type: RTB Safety Instructions BVH2539 GB PASS - A service you can count on. Fast, comprehensive and anywhere in the world. Quality and reliability are the cornerstones of our company s philosophy.

More information

EuroFID Total Hydrocarbon Analyzer

EuroFID Total Hydrocarbon Analyzer Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Analyzers and Process Instrumentation Proven Analyzer

More information

MINI ON-SITE ELECTROLITIC PLANT FOR SODIUM HYPOCHLORITE PRODUCTION

MINI ON-SITE ELECTROLITIC PLANT FOR SODIUM HYPOCHLORITE PRODUCTION MINI ON-SITE ELECTROLITIC PLANT FOR SODIUM HYPOCHLORITE PRODUCTION With maximum capacity of 50 g/h, which is 1.2 kg/day, of the equivalent chlorine. H50 mini can disinfect 28 l/s water and make 0.5 mg/l

More information

PORTABLE ULTRASONIC HARDNESS TESTER

PORTABLE ULTRASONIC HARDNESS TESTER PORTABLE ULTRASONIC HARDNESS TESTER MET-U1A MET-U1A ULTRASONIC HARDNESS TESTER, 15N TESTFORCE FEATURES The INNOVATEST MET-U1A differs completely from traditional hardness testers. Instead of measuring

More information

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter

OWNERS MANUAL. Micro TPI Field Portable Turbidimeter OWNERS MANUAL Micro TPI Field Portable Turbidimeter HF scientific, inc. 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643 Email: Info@hfscientific.com Manual Part No. 22666 (12/04)

More information

???? Spot Check Measurement Simple, accurate, reliable

???? Spot Check Measurement Simple, accurate, reliable Spot Check Measurement Simple, accurate, reliable???? Always a step ahead The development of a new measurement system For more than 60 years, Dräger Sicherheitstechnik GmbH has developed, produced, and

More information

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation USER MANUAL Contents Safety Precautions. 3 Cabinet Assembly 4 Operating buttons / functions.5-6 Machine Operation...7-11 Convert from Inches to Millimeters / Millimeters to Inches.. 7 Programming in Manual

More information

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5 Manual Rotary Heat Sealers Type: F108TX List of content : Page: Introduction 2 General description 3 Application 4 Safety precautions 5 Transport and storage 6 Installation 7 First Set-up 8 Connection

More information

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators

Ordering Information. Conductive Level Controller 61F-GP-N2. Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Conductive Level Controller CSM DS_E_1_ Automatic Water Supply and Drainage Control Ideal for level control of any conductive liquid. Compact plug-in controller for single- or two-point control of conductive

More information

Model FDL 115 Safety drying chambers for limited quantities of solvent

Model FDL 115 Safety drying chambers for limited quantities of solvent Model FDL 115 Safety drying chambers for limited quantities of solvent The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and

More information

Model BF 720 Incubators Avantgarde.Line with forced convection

Model BF 720 Incubators Avantgarde.Line with forced convection Model BF 720 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly

More information

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale Instruction Manual DRS220 Digital Refrigerant Scale DRS220 Digital Refrigerant Scale Limited Warranty The DRS220 Digital Refrigerant Scale is warranted to be free from defects in materials and workmanship

More information

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523

Guide book AS 300 G. Waste water filtration unit. Im Geer 20, D Isselburg. Description / Type-No.: AS 300 G Type 523 Waste water filtration unit Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type-No.: Type 523 Table of contents on Page 1 Introduction 3 2 Basic safety advice 4 2.1 Intended use

More information

Agilent 16047D Test Fixture

Agilent 16047D Test Fixture Agilent 16047D Test Fixture Operation and Service Manual Third Edition Agilent Technologies Japan, Ltd. Agilent PN 16047-90300 May 2000 Printed in Japan Notices The information contained in this document

More information

Reference thermometer Model CTP5000

Reference thermometer Model CTP5000 Calibration technology Reference thermometer Model CTP5000 WIKA data sheet CT 61.20 Applications Reference thermometer for measuring very accurate temperature in a range of -196... +660 C [-321... +1,220

More information

Adjustable Fused Power Supply

Adjustable Fused Power Supply User & Installation Manual EN Adjustable Fused Power Supply 7-20V 3A P010-52 Contact & Product mo-vis BVBA Biebuyckstraat 15 D 9850 Nevele - Belgium Website: www.mo-vis.com E-mail: contact@mo-vis.com Telephone:

More information

ARCHITECTS PANELS APPLICATIONS AND TECHNICAL SPECIFICATIONS ENGLISH

ARCHITECTS PANELS APPLICATIONS AND TECHNICAL SPECIFICATIONS ENGLISH ARCHITECTS PANELS APPLICATIONS AND TECHNICAL SPECIFICATIONS ENGLISH SKALA THE AVANCIS ARCHITECTS PANEL The AVANCIS SKALA solar panel is the architectural PV module series designed as a premium component

More information

DJ Switch 10F V2 ORDERCODE 50365

DJ Switch 10F V2 ORDERCODE 50365 DJ Switch 10F V2 ORDERCODE 5035 Congratulations! You have bought a great, innovative product from Showtec. The Showtec DJ Switch brings excitement to any venue. Whether you want simple plug-&-play action

More information

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches

Switch-Tek. LV41 & LV42 Series Manual. Sump Float Level Switches Switch-Tek Sump Float Level Switches LV41 & LV42 Series Manual LV41 Series Shown LV42 Series Shown Flowline, Inc. 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507 w flowline.com

More information

NTC thermistors for temperature measurement

NTC thermistors for temperature measurement NTC thermistors for temperature measurement Series/Type: Date: March 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

EGT-AF08 USER GUIDE WHEEL WEIGHING SYSTEMS WITH VARIOUS PLATFORMS

EGT-AF08 USER GUIDE WHEEL WEIGHING SYSTEMS WITH VARIOUS PLATFORMS EGT-AF08 USER GUIDE WHEEL WEIGHING SYSTEMS WITH VARIOUS PLATFORMS Revision 1.00 Last update 01/02/2013 Page intentionally left blank. EGT-AF01 USER GUIDE Table of contents 1 INTRODUCTION... 5 2 TECHNICAL

More information

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.

More information

Electricity and Chemistry

Electricity and Chemistry Electricity and Chemistry Electrochemistry: It is a branch of chemistry that deals with the reactions involving the conversion of chemical energy into electrical energy and vice-versa. Electrochemical

More information

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters

Instruction Manual. HI HI Portable ph/ec/tds/ C Meters Instruction Manual HI 9812-0 HI 9812-5 Portable ph/ec/tds/ C Meters w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully

More information

MICRO-INVERTER PIGRID W MICRO GRID TIED INVERTER 208, 220, 230, 240VAC

MICRO-INVERTER PIGRID W MICRO GRID TIED INVERTER 208, 220, 230, 240VAC MICRO-INVERTER PIGRID250 250W MICRO GRID TIED INVERTER 208, 220, 230, 240V TECHNICAL MANUAL CONTENTS INTRODUCTION ------------------------------------------------------------------------------ 3 SAFETY

More information

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1 CONTENTS 1. Introduction... 1 2. Precautions... 1 3. Before Using the Product 3-1 Unpacking and Checking. 1 3-2 Installing Components.... 1 3-3 Leveling the Scale.... 1 4. Product Introduction 4-1 Specifications

More information

AS950 ALL-WEATHER REFRIGERATED SAMPLER

AS950 ALL-WEATHER REFRIGERATED SAMPLER AS950 ALL-WEATHER REFRIGERATED SAMPLER Applications Wastewater Collection systems Industrial pretreatment Environmental monitoring Stormwater Sampling has never been this easy. Hach's AS950 sampler controller

More information

DS-520 Digital Indicator Operation Manual 73366

DS-520 Digital Indicator Operation Manual 73366 DS-520 Di gi tal Indi cator Operation Manual 73366 SECTION DS-520 SERIES OPERATING MANUAL INDEX PAGE NUMBER 1.0 GENERAL 2-3 1.1. Features 2 1.2. Keyboard & Display Layout 2 1.3. Key Switch Information

More information

Hydrogen and fuel cell technology Assembly instructions and experiment templates

Hydrogen and fuel cell technology Assembly instructions and experiment templates Hydrogen and fuel cell technology Assembly instructions and experiment templates T203 TUTORIAL Pro 1 2 www.h-tec-education.com Table of contents 05 05 05 06 09 10 11 15 21 27 33 39 47 48 49 49 49 50 The

More information

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65

Operation Manual. Professional Weighing Equipment. MRW SERIES intelligent weighing scale. WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65 Professional Weighing Equipment MRW SERIES intelligent weighing scale WASHDOWN WEIGHING SCALE - Dust and Waterproof Scale IP65 WITH PIECE COUNTING FUNCTION Operation Manual Section Table of Contents Page

More information

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands MANUAL ENGLISH Antenna Booster V1 Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands Table of contents Warning... 2 Unpacking Instructions... 2 Safety Instructions... 2 Operating

More information

GLASS-LINED INSTRUMENTATION FOR HIGHEST STANDARDS. 60 C 2 mbar 70% PLC CONTROLS

GLASS-LINED INSTRUMENTATION FOR HIGHEST STANDARDS. 60 C 2 mbar 70% PLC CONTROLS GLASS-LINED INSTRUMENTATION FOR HIGHEST STANDARDS 60 C 2 mbar 70% PLC CONTROLS Pfaudler Group One single source responsibility with access to all Pfaudler Technologies, Solutions, Services worldwide Pfaudler

More information

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual DMX-BRANCH/4 user manual ELATION DMX-BRANCH/4 user manual 2016 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without

More information

DIGITAL PORTION SCALE PS-5 OWNER S Manual

DIGITAL PORTION SCALE PS-5 OWNER S Manual DIGITAL PORTION SCALE PS-5 OWNER S Manual CARDINAL SCALE MFG. CO. 8528-M013-O1 Rev G PO BOX 151 WEBB CITY, MO 64870 Printed in USA 09/00 PH (417) 673-4631 FAX (417) 673-5001 Web Site - http://www.detectoscale.com

More information

INDEX. 1 Introduction. 2 Software installation. 3 Open the program. 4 General parameters. 5 Tuning

INDEX. 1 Introduction. 2 Software installation. 3 Open the program. 4 General parameters. 5 Tuning SET UP MANUAL INDEX 1 Introduction 2 Software installation 3 Open the program 4 General parameters 5 Tuning 2 1 Introduction Here below the instruction to use the FLYJET software. 1.1 Software features

More information

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas MRU over 30 years of innovative gas analysis! Biogas analysers Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas Product overview MRU Biogas analysers Whether biogas, landfill and coal mine

More information

ARCHITECTS PANELS APPLICATIONS AND TECHNICAL SPECIFICATIONS ENGLISH

ARCHITECTS PANELS APPLICATIONS AND TECHNICAL SPECIFICATIONS ENGLISH ARCHITECTS PANELS APPLICATIONS AND TECHNICAL SPECIFICATIONS ENGLISH SKALA THE AVANCIS ARCHITECTS PANEL The AVANCIS SKALA solar panel is the architectural PV module series designed as a premium component

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

Model M120 Mini Temperature/Humidity Meter

Model M120 Mini Temperature/Humidity Meter Model M120 Mini Temperature/Humidity Meter 2 Table of Contents 1 INTRODUCTION... 3 1.1 The M120 features:... 3 2 SAFETY SUMMARY... 4 3 COMPLIANCE STATEMENTS... 5 4 PRODUCT CONTENTS AND INSPECTION... 5

More information

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit

Tintometer -Group. MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit Tintometer -Group MicroDirect (IP 67 waterproof) Optional temperature measurement Celsius/ Fahrenheit ph ORP/Redox Conductivity TDS Salinity Temperature 110 Regularly updated information: www.tintometer.com

More information

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring. High /H comp NO NOx 2 LANM 4 www.lancom4.com NO2 2 H2S SO2 CXHY Portable Flue Gas Monitoring LANM 4 The Lancom 4 is the most accurate, robust and flexible portable flue gas analyser currently available.

More information

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives. Instruction Manual HI 8666 RH/ C Transmitter This Instrument is in Compliance with the CE Directives www.hannainst.com Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this

More information

PD662 Loop-Powered Meter Instruction Manual

PD662 Loop-Powered Meter Instruction Manual PD662 Loop-Powered Meter C US 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Loop-Powered Backlight Option 1.7 Volt Drop without Backlight 32-Point and

More information

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710 Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710 Operator manual Information on the manual Information on the manual Please read this manual, before using the change-over

More information

Coating Thickness Meter Data Sheet / Instructions

Coating Thickness Meter Data Sheet / Instructions Paint Test Equipment Coating Thickness Meter Data Sheet / Instructions Coating Thickness Meter Information The Paint Test Equipment Coating Thickness Meter easily measures all coatings on metallic substrates

More information

HI Portable Logging Turbidity Meter with RS232. Instruction Manual MAN R1 08/05 HI LOG LOBAT DATE TIME CLR VIEW ON OFF STO

HI Portable Logging Turbidity Meter with RS232. Instruction Manual MAN R1 08/05 HI LOG LOBAT DATE TIME CLR VIEW ON OFF STO Instruction Manual Portable Logging Turbidity Meter with RS232 % TIME LOG LOBAT 188 MAN93703-11R1 08/05 Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully

More information

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm) CSM_PS-_S(R)_-31_DS_E_7_1 Separate s for Water Supply and Drainage Control in Buildings. Small, Lightweight s for Use as Built-in Components. The PS-@S(R) are separate s that allow the s to be withdrawn

More information

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD: GENERAL DESCRIPTION Crude oil well test manifold to be provide as Multiport Flow Selector (MPFS) technology. It provides a cost effective method for selecting and diverting well fluids from an individual

More information

GAS 3050P NDIR FLUE GAS

GAS 3050P NDIR FLUE GAS Portable gas analyser GAS 3050P NDIR FLUE GAS Industrial flue gas analysis Powerful, robust and transportable on any industrial site, the GAS 3050P NDIR FLUE GAS analyser offers the same performances as

More information

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters

The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters Committing to the future testo 327-1/-2 The Fast and Robust Flue Gas Measuring Instrument for All Important Parameters NEW! O 2 CO 2 C hpa CO O 2 EN 50379-2 and 1. BImSchV TÜV-tested for O 2, C, hpa The

More information

HY-ALERTA 500 Handheld Hydrogen Leak Detector

HY-ALERTA 500 Handheld Hydrogen Leak Detector HY-ALERTA 500 Handheld Hydrogen Leak Detector Our Mission Deliver unsurpassed value and optimize green initiatives with our one of a kind continuous hydrogen-specific sensing technology worldwide. Our

More information

Industrial flue gas probes. Instruction manual

Industrial flue gas probes. Instruction manual Industrial flue gas probes Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 4 2.1. About this document... 4 2.2. Ensure safety... 4 2.3. Protecting the environment...

More information

Agilent 1260 Infinity RID User Manual. 9 Maintenance

Agilent 1260 Infinity RID User Manual. 9 Maintenance Agilent 1260 Infinity RID User Manual 9 Maintenance Introduction to Maintenance 130 Warnings and Cautions 131 Detector Maintenance Procedures 133 Cleaning the Module 134 Flow Cell Flushing 135 Correcting

More information

4Ch Real time / Duplex LCD Combo DVR

4Ch Real time / Duplex LCD Combo DVR 4Ch Real time / Duplex LCD Combo DVR The most stable and reliable real stand alone Digital Video Multiplex Recorder Installation & Safeguards INSTALLATION & SAFEGUARDS All the safety and operating instructions

More information

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide

AM1620 Precision Industrial Platinum Resistance Thermometer User s Guide AM1620 Precision Industrial Platinum Resistance Thermometer Table of Contents Before you start ---- Warnings & Cautions... 2 1 Introduction... 3 1.1 Main Application... 3 1.2 Main Features... 3 1.3 Calibrations...

More information

NEW GC-16 IN WEST KUWAIT MATERIAL REQUISITION FOR LEVEL GAUGE TABLE OF CONTENTS

NEW GC-16 IN WEST KUWAIT MATERIAL REQUISITION FOR LEVEL GAUGE TABLE OF CONTENTS TABLE OF CONTENTS Sh. 2 of 16 1 INTRODUCTION 4 1.1 Purpose 4 1.2 Definitions 4 1.3 Acronyms 4 1.4 Codes and Standard 5 1.5 Environmental Condition 6 1.6 Language 6 1.7 Units of Measurement 7 1.8 General

More information

HDI 2200 Choke Position Indicator

HDI 2200 Choke Position Indicator HDI 2200 Choke Position Indicator Operations and Maintenance Manual Rev. 1203 www.houstondigital.com email: sales@houstondigital.com or service@houstondigital.com TABLE OF CONTENTS SECTION 1 SECTION 2

More information

testo 616 Appareil de mesure de l'humidité

testo 616 Appareil de mesure de l'humidité testo 616 Materialfeuchte-Messgerät Material moisture measuring instrument Appareil de mesure de l'humidité des matériaux. Bedienungsanleitung Instruction manual Mode d emploi Content 17 Content General

More information

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control Sampling Stationary Portable Sampling is an important factor for the compliance with required regulations and efficient operation. It forms the basis for continuous monitoring objectives and criteria,

More information

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual XSTi Standby UPS 400VA, 600VA, 800VA Models User & Installation Manual www.xpcc.com 2015. All rights reserved. (Rev 12/14/15) Table of Contents Package Contents... 3 Product Introduction... 3 Product Overview...

More information

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF Daker DK 4.5-10 kva Parallel installation quick start Part. LE08927AA-09/15-01 GF Daker DK 4.5-10 kva UK ENGLISH 3 2 Daker DK 4.5-10 kva Index Introduction 2 1 Important Safety Instructions 2 2 Parallel

More information

Using the PPM2 Portable Trace Moisture Transmitter

Using the PPM2 Portable Trace Moisture Transmitter APPLICATION NOTE 2016_0106 PPM2 Using the PPM2 Portable Transmitter The Model PPM2 Portable analyzer is a compact, cost effective, analyzer specifically designed to continuously measure low levels of moisture

More information

Sby SR Instruments, Inc.

Sby SR Instruments, Inc. Part No.: MAN947IFS_170629 Page 1 of 12 Sby SR Instruments, Inc. SRV947IFS REMOTE DISPLAY PLATFORM SCALE Operating and Service Manual Part No.: MAN947IFS_170629 Page 2 of 12 TABLE OF CONTENTS TABLE OF

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the FLOWSIC100 Gas Flowmeter Manufactured by: SICK Engineering GmbH Bergener Ring 27 01458 Ottendorf-Okrilla Germany Has been assessed by Sira Certification

More information

Winzer Corporation 1 Revision: 4.0

Winzer Corporation 1 Revision: 4.0 Table of Content Section 1: Getting Started... 2 1.1 Overview... 2 Section 2: Installation Overview... 3 2.1 Install CD / Start.exe... 3 2.2 Welcome Screen... 4 2.3 Device Selection... 4 2.4 Auto or Industrial...

More information

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00 PMA 31-G English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and

More information

Animal Activity Monitor

Animal Activity Monitor Animal Activity Monitor March 2010 INSTRUCTION MANUAL Activity Monitor for Raturn 2701 Kent Avenue West Lafayette Indiana 47906 www.basinc.com BASi products are trademarks of Bioanalytical Systems, Inc.

More information

4.1 Reduction/elimination of environmentally sensitive materials

4.1 Reduction/elimination of environmentally sensitive materials IEEE Standard 1680 Section 4 Environmental performance criteria for desktop personal computers, notebook personal computers and personal computer monitors This document paraphrases the environmental criteria

More information

WLC60 Heavy Duty LED Light

WLC60 Heavy Duty LED Light Datasheet Banner's WLC60 Heavy Duty Lights are engineered to withstand harsh environments, making it the first choice for a machine lighting solution. A conservative mechanical design protects against

More information

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com

OM-90 SERIES Portable Temperature and Humidity Data Loggers. Shop online at omega.com TM For complete product manual: www.omega.com/manuals/manualpdf/m5440.pdf Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info OM-90 SERIES Portable Temperature

More information

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31) Best Selection for Your Business Electronic Pricing Scale User s Manual (Model: TP-31) CATALOG 1. Foreword... 2 1.1. Introductions... 2 1.2. Main functions and features... 2 1.3. Specification... 2 1.4.

More information

Compact Electro Plating Machine - CEPM-2A USER MANUAL

Compact Electro Plating Machine - CEPM-2A USER MANUAL 1 Compact Electro Plating Machine - CEPM-2A USER MANUAL PRODUCT INTRODUCTION: This compact electroplating machine is a high performance compact plating unit that is especially designed for coating all

More information

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010) Adam Equipment LBH SERIES (P.N. 700660113, Revision B2, January 2010) Adam Equipment Company 2010 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed

More information

PORTABLE HARDNESS TESTING

PORTABLE HARDNESS TESTING Portable Hardness Tester IPX-300 Handheld dynamic metal hardness tester with hardness conversion and automatic position setting. Dynamic hardness testing: quick and reliable Impact device D integrated:

More information

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

HI Multiparameter Photometers with up to 44 Measurement Methods.  ISO 9001:2000 Certified HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to 44 Measurement Methods ISO 9001:2000 Certified www.hannainst.com/usa HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to

More information

Infrared thermometer. testo 835 fast, accurate infrared measuring instruments for trade and industry. Data sheet testo 835

Infrared thermometer. testo 835 fast, accurate infrared measuring instruments for trade and industry.  Data sheet testo 835 Data sheet testo 835 Infrared thermometer testo 835 fast, accurate infrared measuring instruments for trade and industry Measure safely and accurately even at high temperatures 4-point laser shows the

More information

Instruction Manual Dräger MSI EM200-s

Instruction Manual Dräger MSI EM200-s Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 950; Edition 2011-01-01 Content 1. Reference notes Page 3 1.1 Approvals 1.2 Information

More information

KEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime

KEy FEATuRES. Virtually maintenance free. No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime KEy FEATuRES Virtually maintenance free No interference from glycol, methanol or amine contaminants (vapor phase) Fast and accurate realtime measurements No wet-up or dry-down delays Short term payback;

More information

Model BF 260 Incubators Avantgarde.Line with forced convection

Model BF 260 Incubators Avantgarde.Line with forced convection Model BF 260 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly

More information

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas MRU over 30 years of innovative gas analysis! Biogas analysers Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas Product overview MRU Biogas analysers Whether biogas, landfill and coal mine

More information

Digital Hydrometer SBS-3500 INSTRUCTION MANUAL. Storage Battery Systems LLC Instruction Manual for SBS-3500 Digital Hydrometer Rev.

Digital Hydrometer SBS-3500 INSTRUCTION MANUAL. Storage Battery Systems LLC Instruction Manual for SBS-3500 Digital Hydrometer Rev. Digital Hydrometer SBS-3500 INSTRUCTION MANUAL Storage Battery Systems LLC Instruction Manual for SBS-3500 Digital Hydrometer Rev. 09-15 While every precaution has been taken in the preparation of this

More information

MEDIZINTECHNIK FÜR TIERÄRZTE

MEDIZINTECHNIK FÜR TIERÄRZTE GB Tabel of contents: Operation Instructions Electronic Platfoorm Balances MEDIZINTECHNIK FÜR TIERÄRZTE 1 Technical data 17 2 Fundamental information (general) 18 2.1 Intended use 18 2.2 Inappropriate

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com AT210 Soil Moisture

More information

nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual

nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual Copyright 2014 Eppendorf AG, Germany. No part of this publication may be reproduced without the prior

More information

COATING THICKNESS MEASURING

COATING THICKNESS MEASURING LIST- MAGNETIK COATING THICKNESS MEASURING www.list-magnetik.de COATING THICKNESS MEASURING on metallic substrate magnetic induction measuring method Paint Zinc coating eddy current measuring method d2

More information

Analysis O2, CO, CO2. Applications. Characteristics. System. Air monitoring. Measurands O 2, CO, CO 2. Measurement in liquids

Analysis O2, CO, CO2. Applications. Characteristics. System. Air monitoring. Measurands O 2, CO, CO 2. Measurement in liquids GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 www.ghm-group.de info@ghm-group.de Analysis System Analysis oxygen, carbon

More information

Agilent 4339B/4349B High Resistance Meters Technical Overview

Agilent 4339B/4349B High Resistance Meters Technical Overview Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance

More information