Accreditation No: LAB 023
|
|
- Kelly Ethel Chase
- 6 years ago
- Views:
Transcription
1 Accreditation No: Awarded to Chemical & Environmental Laboratory, SGS Pakistan Private Limited. Karachi, Pakistan. H-3/3, Sector 05, Korangi Industrial Area, Karachi, UAN The scope of accreditation is in accordance with the standard specifications outlined in the following page(s) of this document. The accredited scope shall be visible and legible in areas such as customer service, sample-receiving section etc and shall not mislead its users. The accreditation was first time granted on by Pakistan National Accreditation Council. The laboratory complies with the requirements of ISO/IEC 17025:. The accreditation requires regular surveillance, and is valid until The decision of accreditation made by Pakistan National Accreditation Council implies that the organization has been found to fulfill the requirements for accreditation within the scope. The organization however, itself is responsible for the results of performed measurements/tests. PAKISTAN NATIONAL ACCREDITATION COUNCIL General Page 1 of 10
2 Testing Laboratory. Chemical & Environmental Laboratory, SGS Pakistan Private Limited. Karachi, Pakistan. Permanent laboratory premises: H-3/3, Sector 05, Korangi Industrial Area, Karachi, Chrome Ore Chromium Chrome Ore Alumina Chrome Ore Silica Chrome Ore Iron Iron Ore Iron Iron Ore Silica CCO/01 Based on ISO (E) ACO/04 ACO/04- A Based on ISO (E) & IS SCO/02 Based on ISO (E) Based on ISO (E) ICO/03 Based on ISO (E) ACO/09 IIO/05 Based on ISO (E) SIO/06 Based on ISO (E) Page 2 of 10
3 Iron Ore Alumina Fertilizer Nitrogen Fertilizer Total Phosphate MNTP/2009/AlO/07 Based on ISO NDU/10Non standard method, Based on AOAC , & th Edition (2016) TPF/11 Based on AOAC th Edition (2016) Fertilizer Page 3 of 10 Water soluble Phosphate Coal and Coke Ash Content Coal and Coke Calorific Value Coal and Coke Total Moisture in Coal Coal and Coke Total Sulfur WPF/12 Based on AOAC th Edition (2016) ACCC/14 Based on ASTM D & ISO 1171: 2010(E) CVCC/16 ASTM D & ISO 1928: 2009 TMC/17 Based on ASTM D , D3302 / 3302M-15 & ISO E TSCC/13 Based on ASTM D & ASTM D e2
4 Coal and Coke Total Moisture in Coke Water Aluminum Water Manganese Water Iron Water Chromium Water Copper Water Zinc TMC/16 Based on ASTM D & ISO 579:2013 E MW/08 Based on ASTM D857-12, APHA 3111 D & 3120B MW/08 Based on ASTM D APHA 3111 B & 3120B MW/08 Based on ASTM D , APHA 3111 B & 3120B MW/08 Based on ASTM D , APHA 3111 B & 3120B MW/08 Based on ASTM D , APHA 3111 B & 3120B MW/08 Based on ASTM D , APHA 3111 B & 3120B Page 4 of 10
5 Water Nickel Water Cadmium Water Lead Water Alkalinity MW/08 Based on ASTM D , APHA 3111 B & 3120B, MW/08 Based on ASTM D , APHA 3111 B & 3120B MW/08 Based on ASTM D , APHA 3111 B (AAS) & 3120B (ICP), AW/18 Based on APHA 2320B Water Biochemical Oxygen Demand BOD/24Non standard method, Based on APHA 5210 D Water Chlorides Water Chemical Oxygen Demand CW/19 Based on APHA 4500 B &Cl - COD/20 Based on APHA 5220 B COD/25 Based on APHA 5220 D Page 5 of 10
6 Water Ca and Mg Water ph Value Water Total Dissolved Solid Water Total Hardness CMW/26 (AAS) Based on APHA CaB Based on APHA MgB Based on APHA 3110,3111-B & D Based on APHA 3111-B & 3120 A ph/27 Based on APHA H + B TDS/22 Based on APHA 2540 C THW/28 Based on APHA 2340 B & C Water Total Suspended Solid TSS/23 Based on APHA 2540D Water Sulphate SW/29 Based on APHA 4500 C SO4-2 Page 6 of 10
7 Mechanical & Physical Testing Lead Copper Zinc Cobalt Nickel Silver Sample Preparation rocks & minerals by Scott. rocks & minerals by Scott rocks & minerals by Scott rocks & minerals by Scott rocks & minerals by Scott rocks & minerals by Scott SPGC/31 Based on SGS Mineral Sampling Manual Page 7 of 10
8 Cement Calcium Oxide Cement Silica Cement Aluminium Oxide Cement Iron (III) Oxide Cement Magnesium Oxide Cement Loss on Ignition Cement Sulfate MNTP/2010/SOP-CMC/35 MNTP/2010/SOP-SiC/33 MNTP/2010/SOP-MC/34 MNTP/2010/SOP-MC/34 Non standard Non standard method, Based on BS EN : MNTP/2010/SOP-CMC/35 MNTP/2010/SOP-LOIC/36 MNTP/2010/SOP-SC/38 Page 8 of 10
9 Cement Alkali content (Na2O & K2O) Cement Physical Testing Compressive Strength MNTP/2010/SOP-AC/37 BS EN :, ASTM C109 / C109M-16a PS-232:2008, ISO Tested at 20 o C & 27 o C Cement Physical Testing Setting Time BS EN : & ASTM C Cement Physical Testing Soundness BS EN : Cement Physical Testing Fineness BS EN : 1992 & ASTM C Manganese ores Manganese content MNTP/2010/SOP-J-Mn/40 MNTP/2010/SOP-AAS- Mn/39 Non standard method, Based on JIS M & F.A. Julian, J. Am. Chem. Soc., 15, 113 Page 9 of 10
10 Calibration Laboratory. Accreditation Scope of ABC Lab. PQR City, XYZ Country. Permanent laboratory premises X Field of measurement: Measured quantity Range Calibration & Measurement Capability (CMC) expressed as an uncertainty ( + ) Brief description of measurement and equipment used Page 10 of 10
Accreditation No: LAB 067. SGS Chemical, Environmental & Microbiological Lab Lahore, Pakistan
Issue : 02/05/12 Accreditation No: Awarded to SGS Chemical, Environmental & Microbiological Lab Lahore, Pakistan The scope accreditation is in accordance with the stard specifications outlined in the following
More informationKKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana
Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m
More informationREPORT NUMBER REPORT DATE SEND TO ISSUE DATE Apr 18, Apr 18, 2017 RECEIVED DATE Apr 05, 2017
PAGE 1/7 Sample ID: EWA PELLETS Lab Number: 2653281 Date Sampled: 2017-04-04 0850 Carbon nitrogen ratio C/N 6 : 1 0.1 Calculation Auto-2017/04/12 Auto-2017/04/18 Carbon (total) 38.53 % 0.050 ASTM D 5373
More informationHaryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date
Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9
Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 %
More informationAppendix C1: Batch Kinetics Tests
Appendix C1: Batch Kinetics Tests This appendix contains the entire data set for the batch kinetics tests for the potential biofilter components. These tests were performed to provide estimates of optimal
More informationCERTIFIED REFERENCE MATERIALS (CRM)
CERTIFIED REFERENCE MATERIALS (CRM) Sufficiently Homogenized Indian Reference Materials certified by Round robin analysis for the use of validation of methods and calibration. CSIR-National Metallurgical
More informationENVIRONMENTAL LABORATORY LICENSE. ACZ Laboratories, Inc. AZ0102
ARIZONA DEPARTMENT OF HEALTH SERVICES ENVIRONMENTAL LABORATORY LICENSE Issued to: Laboratory Director: Owner/Representative: Brett Dalke Matt Sowards ACZ AZ0102 is in compliance with Environmental Laboratory
More informationLIST OF DAC (17025) ACCREDITED TESTS CONSTRUCTION MATERIALS TESTING. Determination of sulphate content of soil and ground water testing
LIST OF DAC (17025) ACCREDITED TESTS CONSTRUCTION MATERIALS TESTING WATER: Material / Product Description Chemical Water Determination of ph Value 02 Chemical Water Determination of sulphate content of
More informationLABORATORY TURNAROUND TIMES AND CHARGES
LABORATORY TURNAROUND TIMES AND CHARGES The enclosed prices reflect a 5 business day turnaround time. There will be a $25.00 minimum charge per report. Same Day Rush 24 Hour Rush 48 Hour Rush 72 Hour Rush
More informationREVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS)
REVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS) Background PEPC in its first meeting held on 10 th May 1993 approved the NEQS. The approved NEQS were uniform standards applicable to all kind of
More informationMicro Methods Laboratory Quality Assurance Manual
15.2 List of Approved Methods Petroleum Analysis Methodology Reference Table Method ASTM 977 ASTM C25 ASTM C39 ASTM D129 ASTM D1298 ASTM D156 ASTM D1744 ASTM D189 ASTM D2159 ASTM D2270 ASTM D2276 ASTM
More informationfor production of 2-[ F]-fluoro-2-deoxy-D-glucose with the
Reagents Kit 18 for production of 2-[ F]-fluoro-2-deoxy-D-glucose with the GE TRACERlab MX FDG Module Catalog No.: RK-100 Date of Manufacturing: Sep.16 2008 Lot No.: RK-100-080916 Expiry Date: Sep.15 2009
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Metals and Minerals Division 2 Perry Road Witham Essex CM8 3TU Contact: Mrs C Hargreaves Tel: +44 (0)1376 536800 Fax: +44 (0)1376 520819 E-Mail:
More informationPROFICIENCY TESTING PROGRAMS SOILS & INPUTS
PROFICIENCY TESTING PROGRAMS SOILS & INPUTS A15 15a 24 A38a A38b 45 Soils Fresh soils Mineral fertilizers Activated sludge, sediments, Soil: Physico-chemistry Activated sludge, sediments, Soil: Micropollutants
More informationUtilization of micro silica as partial replacement of OPC & SRC in concrete
International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 3, Issue 3(March 2014), PP.67-73 Utilization of micro silica as partial replacement of
More informationFORM 26R CHEMICAL ANALYSIS OF RESIDUAL WASTE ANNUAL REPORT BY THE GENERATOR INSTRUCTIONS GENERAL INFORMATION
COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF WASTE MANAGEMENT FORM 26R CHEMICAL ANALYSIS OF RESIDUAL WASTE ANNUAL REPORT BY THE GENERATOR INSTRUCTIONS GENERAL INFORMATION
More informationContaminated Extraction Pit treated to allow dewatering for continuation of mining works
Contaminated Extraction Pit treated to allow dewatering for continuation of mining works Name Customer name withheld Site Location South East Queensland Site Problem ph, Acidity and Dissolved Metals Water
More informationNewmont Mining Corporation Water Management Standard
Page No: Page 1 of 5 1 PURPOSE AND OBJECTIVES This Global Standard sets the minimum Newmont requirements to proactively plan and manage water from exploration to post-closure in accordance with Newmont
More informationWarm Mineral Springs Sampling by Sarasota County
Warm Mineral Springs Sampling by Sarasota County John Ryan, Kathryn Meaux, Rene Janneman and Jon S. Perry Sarasota County Environmental Services Sarasota, Florida September 11 Warm Mineral Springs is a
More informationLocked Cycle Leaching Test and Yellowcake Precipitation
Locked Cycle Leaching Test and Yellowcake Precipitation In 2013, the Saskatchewan Research Council ( SRC ) in Saskatoon, SK, Canada commenced locked cycle alkaline leach testing on drill core samples from
More informationOne of the main ores of zinc is zinc blende, ZnS. There are two stages in the extraction of zinc from this ore.
1 Two of the main uses of zinc are for galvanising and for making alloys. One of the main ores of zinc is zinc blende, ZnS. There are two stages in the extraction of zinc from this ore. (a) Stage 1 Zinc
More informationAbu Dhabi Trade Effluent Standards & Regulations Summary
Abu Dhabi Trade Effluent Standards & Regulations Summary August 2010 Disclaimer: The standards & regulations provided here are attributable to the named source and are assumed to be accurate at the time
More informationEnvironment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra
Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MICROBAC LABORATORIES, INC., KTL DIVISION 3323 Gilmore Industrial Blvd. Louisville, KY 40213 Megan Rothgerber Phone: 502 962 6400 CHEMICAL Valid To: December
More informationPrice List. Prices valid until 31 December 2016
Price List Prices valid until 31 December 2016 APAL Agricultural Laboratory- Pricelist- valid until 31 st December 2016 (Edition 1) Soil Reporting Options - All pricing is based on data only. Additional
More informationSCOPE OF ACCREDITATION TO ISO GUIDE LECO CORPORATION 3000 Lakeview Avenue St. Joseph, MI Mr. Dennis Lawrenz Phone:
SCOPE OF ACCREDITATION TO ISO GUIDE 34-2009 LECO CORPORATION 3000 Lakeview Avenue St. Joseph, MI 49085 Mr. Dennis Lawrenz Phone: 269 982 2277 REFERENCE MATERIAL PRODUCER Valid To: May 31, 2018 Certificate
More informationThe Development of. in Hong Kong. Ir. Edward Chow 25 June 2015
The Development of CLP s Pulverized Fuel Ash (PFA) in Hong Kong Ir. Edward Chow 25 June 2015 Agenda CLP Overview Castle Peak Power Station (CPPS) CLP s PFA Studies PFA Applications and Advantages Coal
More informationSeasonal variations in physico-chemical characteristics of ground water collected from Kondapalli nearby VTPS-Vijayawada
Available online at www.derpharmachemica.com Scholars Research Library Der Pharma Chemica, 2015, 7(3):221-225 (http://derpharmachemica.com/archive.html) ISSN 0975-413X CODEN (USA): PCHHAX Seasonal variations
More informationSCOPE OF ACCREDITATION TO ISO GUIDE 34:2009
SCOPE OF ACCREDITATION TO ISO GUIDE 34:2009 SCP SCIENCE 21800 Clark Graham Baie d'urfe, Quebec H9X 4B6 CANADA David Smith Phone: 514 457 0701 dsmith@scpscience.com REFERENCE MATERIAL PRODUCER Valid To:
More informationKirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent
Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent wastewater requirements. In Russia, there are strict
More informationKits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT
Kits Item Product name Article Number 1 ACIDITY TEST AQUAMERCK 1.11108.0001 2 ALCOHOL TEST 15-150 MG/L REFLECTOQUANT 1.17946.0001 3 ALKALINITY TEST AQUAMERCK 1.11109.0001 4 ALUMINIUM TEST 0.020-1.20 MG/L
More informationDistribution Review. Corrosion Control. Corrosion Control Vocabulary. American Water College 1. Corrosion Control Training Objectives
Distribution Review Corrosion Control Corrosion Control Training Objectives To gain an understanding of: Corrosion control vocabulary The factors affecting corrosion Methods used to control corrosion Alkalinity
More informationFinal Report DMR-QA 36. NPDES Permit: IL DMR-QA Study. Open Date: 03/18/16. Close Date: 07/01/16. Report Issued Date: 07/29/16
Keith Richard Decatur Sanitary District Decatur, IL 62522-1842 USA DMR-QA 36 Final Report NPDES Permit: IL0028321 DMR-QA Study Open Date: 03/18/16 Close Date: 07/01/16 Report Issued Date: 07/29/16 Study
More informationMagino Project Environmental Impact Statement. Technical Support Document Environmental Monitoring Plan
Magino Project Environmental Impact Statement Technical Support Document 20-13 Rev. No. Revision Date Approved 0 Document issued for EIS Table of Contents SECTION 1.0 Purpose of the Plan... 1 1.1 Scope
More informationLaboratory Fee Schedule
JMLord, Inc. Laboratory Fee Schedule Spring 2011 www.jmlordinc.com 267 N. Fulton St. Fresno CA, 93705 (559) 268-9755 (559) 486-6504 (FAX) Laboratory Services Since 1976, JMLord, Inc. has provided consultants
More informationMayo Renewable Power Killala Construction Works Monthly Environmental Report 010 April 2016
Mayo Renewable Power Killala Construction Works Monthly Environmental Report 010 April 2016 Executive Summary John Sisk & Son (Holdings) Ltd. commissioned NVM Ltd. to monitor and report on Noise, Dust
More informationSILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/
6360 Gateway Drive, 90630 95073 Page 1 of 8 CI-516 Cistanche 361439388 ICP MS Full Mineral Screen EPA 3050/6020 USP730 BRN Aluminum 2.2 ppm (w/w) Antimony Arsenic 0.06 ppm (w/w) Barium 0.09 ppm (w/w) Beryllium
More informationJordan Water Company/ Miyahuna. Quality, Laboratories and Water Safety Department. Service Price List
Materials/Products Tested: Water (Surface, Ground, Effluent & Distributed Water) 1 Turbidity (Lab) 3 Turbidity (Field Test) 4 Odor 5 Total Alkalinity 6 Phenolphthalein Alkalinity 7 Total Hardness 8 9 Electrical
More informationWater Analysiss. Solutions for photometry
Water Analysiss Reag gents OR Reag NANOCOLOR OR Solutions for photometry Bar coded tube tests with pre-dosed reagents For highest accuracy and sensitivity in water analysis NANOCONTROL for analytical quality
More informationCQA COMPOST QUALITY & VALUE TESTING PARAMETERS REPORT
To: Essex-Windsor SWA CQA Member#: 07-1200 360 Fairview Ave West Essex, Ontario N8M 3G4 Attention: www.compostquality.ca SUMMARY OF ANALYSIS REPORT Sample I.D.: ROW N17 Report#: C18075-10018 C18075-70000
More informationNomenclature. A systematic method of writing chemical formulas and naming compounds
Nomenclature A systematic method of writing chemical formulas and naming compounds Chemical symbols Symbols are used to represent elements Either one capital letter, or a capital letter with a lower case
More informationBackground Statement for SEMI Draft Document 4651 REVISION OF SEMI F GUIDELINES FOR ULTRAPURE WATER USED IN SEMICONDUCTOR PROCESSING
Background Statement for SEMI Draft Document 4651 REVISION OF SEMI F63-0701 GUIDELINES FOR ULTRAPURE WATER USED IN SEMICONDUCTOR PROCESSING Note: This background statement is not part of the balloted item.
More informationISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper
INTERNATIONAL STANDARD ISO 17812 First edition 2007-12-01 Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper Papier, carton et pâtes Détermination
More informationCERTIFICATE OF ANALYSIS
Your Project #: 001\DRINKABLE WATER Your C.O.C. #: na Attention: Michael Bourgon 7111 Syntex Dr Suite 354 Mississauga, ON CANADA L5B 4P5 CERTIFICATE OF ANALYSIS MAXXAM JOB #: B2H1428 Received: 2012/11/01,
More informationJordan Water Company/ Miyahuna Production and Quality Directorate Quality Control and Assurance Department Service Price List
Service List 1 Color Color Materials/Products Tested: Water (Surface, Ground, Effluent & Distributed Water) PHYSICAL TESTS SM 1 B - Visual Comparison Method - Standard Method for Examination of Water and
More informationcalcium oxide removes acidic oxides basic oxides acidic oxides basic oxides Iron obtained from the blast furnace is contaminated with
1 Iron from a blast furnace is treated with and with calcium oxide to make steel. Which substances in the are removed? removes calcium oxide removes acidic oxides basic oxides acidic oxides basic oxides
More informationHongsa Power Company Limited. Integrity, Initiative, Safety & Environment, Present by Pilaipun Teamwork Kamee
Hongsa Power Company Limited Integrity, Initiative, Safety & Environment, Present by Pilaipun Teamwork Kamee Hongsa Mine Mouth Power Project - Construction in Progress A. Introduction B. Project Layout
More informationCore Analysis with the Tracer
BRUKER ELEMENTAL Core Analysis with the Tracer Prepared by: Lee Drake, Senior Application Scientist January 23, 2014 BRUKER ELEMENTAL Key Points OBJECTIVE 3 EXPLORATION 3 DECISION MAKING 3 RECLAMATION
More informationSTATE ENVIRONMENTAL LABORATORY SERVICES DIVISION
STATE ENVIRONMENTAL LABORATORY SERVICES DIVISION FY18 ANALYTICAL FEE SCHEDULE Adjusted to correspond with Consumer Price Index (CPI) of 1.013 APPENDIX A. SAMPLES SUBMITTED BY GOVERNMENT ENTITIES Gas Chromatography/Mass
More informationCERTIFICATE OF ANALYSIS REVISED REPORT
Your C.O.C. #: A122303 Attention: STEPHEN LEGAREE EDMONTON 9331 9331-48 Street EDMONTON, AB CANADA T6B 2R4 Report #: R1787645 Version: 2R CERTIFICATE OF ANALYSIS REVISED REPORT MAXXAM JOB #: B4B4991 Received:
More informationExact Scientific Services, Inc. Ferndale, WA
Ferndale, WA has complied with provisions set forth in Chapter 173-50 WAC and is hereby recognized by the Department of Ecology as an ACCREDITED LABORATORY for the analytical parameters listed on the accompanying
More informationSUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000
SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 100 Fe 200 *** Fe 250 *** Fe 300 Fe 400 Fe 500 Fe 000 Fe low alloy steel cast iron Cr hard / Ni resist stainless steel tool
More informationDrinking Water Analyses
Environmental & Analytical Services 350 Hills Street, Suite 107, Richland, WA 99354 (509) 377-8058 FAX (509) 377-8464 ANALYSES AND PRICE LIST, JANUARY 2016 TO DECEMBER 2016 Drinking Water Analyses BACTERIOLOGICAL
More informationSCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS
SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
ANSI-ASQ National Accreditation Board/ACLASS I. Microbiological / Biological ITEMS, MATERIALS OR, water and, water and, water and, water and, water and, water and, water and SCOPE OF ACCREDITATION TO ISO/IEC
More informationLimestone Neutralisation of Arsenic-rich Effluent from a Gold Mine
Technical Article Limestone Neutralisation of Arsenic-rich Effluent from a Gold Mine M de Beer 1, 2, D Krueger 2, J Maree 1, N Mbhele 1, M Phalanndwa 1, O Novhe 1 1 CSIR, Natural Resources and the Environment,
More informationNotification of Department of Industrial Works
tification of Department of Industrial Works Subject: Type or category of factory required to prepare a report of type and quantity of pollutants discharged from a factory B.E. 2553 (2010) It is deemed
More informationAccredited Laboratory A2LA has accredited WUXI APPTEC, INC. Marietta, GA for technical competence in the field of
Accredited Laboratory A2LA has accredited Marietta, GA for technical competence in the field of Biological Testing This laboratory is accredited in accordance with the recognized International Standard
More informationPage 2. Introduction Page 3. Who should read this brochure? Page 3. Analytical Capability Page 4. Landfill analyses available Page 4
Landfill Analysis Page 2 Table of Contents Introduction Page 3 Who should read this brochure? Page 3 Analytical Capability Page 4 Landfill analyses available Page 4 Closed Landfills Page 6 Leaching Procedures
More informationCOOPERATIVE EXTENSION Bringing the University to You
COOPERATIVE EXTENSION Bringing the University to You Fact Sheet-02-91 SAMPLING AND INTERPRETATION OF LANDSCAPE IRRIGATION WATER Robert Morris and Dr. Dale Devitt TAKING A WATER SAMPLE FOR ANALYSIS Contact
More informationINVESTIGATIONONS ON USE OF JAROSITE AS SET CONTROLLER IN CEMENT
INVESTIGATIONONS ON USE OF JAROSITE AS SET CONTROLLER IN CEMENT S K Agarwal, Puneet Sharma, Mithlesh Sharma and M M Ali National Council for Cement and Building Materials, Ballabgarh & B K Singh and Vikas
More informationThe procedures that are currently being used for classification of fly ash are
CHAPTER 2 PROPERTIES AND CLASSIFICATION OF FLY ASH 2.1 Introduction The procedures that are currently being used for classification of fly ash are reviewed. Some of the significant properties so as to
More informationRECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY
RECYCLED WATER AT SYDNEY OLYMPIC PARK Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY INTEGRATED URBAN WATER CYCLE AT SYDNEY OLYMPIC PARK - CONTEXT INTRODUCTION TO SYDNEY OLYMPIC PARK INTEGRATED WATER
More informationCLEAN WATER Clean Water PT Scheme Schedule Clean Water PT Scheme Schedule. Schedule subject to change see ERA s website at
For International purchase only: Synthetic drinking water matrices with low concentrations of analytes for testing water supply, drinking water, or ground water. Standards are designed to meet the requirements
More informationSoil Test Laboratory Analysis and Fertilizer Recommendations
Soil Test Laboratory Analysis and Fertilizer Recommendations Len Kryzanowski, P.Ag. Director, Environmental Strategy and Research Environmental Stewardship Branch Alberta Agriculture and Forestry Key Messages
More informationPozzolanic Activity of Recycled Red Ceramic Bricks
Pozzolanic Activity of Recycled Red Ceramic Bricks Igor S. Pinheiro, Luiz C. Montenegro, and Adriana G. Gumieri School of Engineering; Federal University of Minas Gerais, Rua Espírito Santo, 35, Belo Horizonte,
More informationEffects of Cement Type and Fly Ash on the Sulfate Attack Using ASTM C 1012
Journal of the Korea Concrete Institute Vol.16 No.1, pp.13~138, February, 24 today s construction industry. Effects of Cement Type and Fly Ash on the Sulfate Attack Using ASTM C 112 Nam-Shik Ahn 1)* Dept.
More informationBy-Products from EAF Dust Recycling and Their Valorisation. Vlad POPOVICI
By-Products from EAF Dust Recycling and Their Valorisation Bredero Shaw, Canada 5 th Global Slag Conference, Brussels, 23-24 November 2009 Agenda Electric Arc Furnace Dust Global Production EAF Dust Recycling
More informationCATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS. The temperature shall not exceed 28 degrees Celsius.
Updated 21 Dec. 2005 CATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS 1 PHYSICAL CHARACTERISTICS (a) Temperature The temperature shall not exceed 28 degrees Celsius. (b) Solids The suspended solids concentration
More informationWater Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water
Water Quality CE 370 Lecture 1 Global Distribution of Earth s s Water Water Demand and Supply in Saudi Arabia Total Water Consumption = 22 billion m 3 /Year Water Demand Water Supply Industrial Domestic
More informationDRAFT OHIO EPA INDUSTRIAL STORMWATER GENERAL PERMIT. I. Comparison with Existing General Permit (OHR000004)
DRAFT OHIO EPA INDUSTRIAL STORMWATER GENERAL PERMIT I. Comparison with Existing General Permit (OHR000004) A. See attached comparison chart courtesy of Curt Spence, Spence Environmental Consulting, Inc.
More informationCANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT
CANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT WATER QUALITY ASSESSMENT OF Salmon River AT SALMON ARM (1985 24) Prepared by: L. G. Swain, P. Eng. B.C. Ministry of Environment Prepared for:
More informationCompounds & Reactions Week 1. Writing Formulas & Balancing Equations. Write the chemical formula for each molecular (covalent) compound.
Compounds & Reactions Week 1 Name Writing Formulas & Balancing Equations Write the chemical formula for each ionic compound. 1. Lithium fluoride 2. Copper (II) chloride 3. Manganese (II) oxide 4. Potassium
More informationThe Release of Base Metals During Acidic Leaching of Fly Ash
The Release of Base Metals During Acidic Leaching of Fly Ash George Kazonich and Ann G. Kim U.S. Department of Energy Federal Energy Technology Center P.O. Box 19 Pittsburgh, PA 153 ABSTRACT Since 199,
More informationTWEED RIVER HIGH SCHOOL 2006 PRELIMINARY CHEMISTRY. Unit 2 Metals
TWEED RIVER HIGH SCHOOL 2006 PRELIMINARY CHEMISTRY Unit 2 Metals Part 2 Metals differ in their reactivity with other chemicals and this influences their uses. Describe observable changes when metals react
More informationWater and Waste Water Management in Yangon, Myanmar
Union of Myanmar Ministry of Agriculture and Irrigation Irrigation Department Water and Waste Water Management in Yangon, Myanmar Mu Mu Than Staff Officer, Irrigation Department Myanmar March,2010 Socio-economical
More informationIBI Certified Biochar Production in California
IBI Certified Biochar Production in California Fifth North American Biochar Symposium Presented on August 24, 2016 by Dr. Alan Propp, PE Syntech Bioenergy www.syntechbioenergy.com/www.gocpc.com SynTech
More information5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 9: METALS 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 9: METALS
5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 9: METALS 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 9: METALS SUB-TOPIC 9.3 TO 5 EXTRACTION OF METALS; RECYLING OF METALS; IRON LEARNING OUTCOMES
More informationAP Chemistry Reaction Set
Class: Date: AP Chemistry Reaction Set 2008-2009 Other 1. Sulfur trioxide gas is bubbled into a solution of sodium hydroxide. (2005) 2. Hydrogen iodide gas is bubbled into a solution of lithium carbonate.
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 6 Finchwell Close Contact: Mr M Collier Handsworth Tel: +44 (0)114-2437271 Sheffield Fax: +44 (0)114-2437288 South Yorkshire E-Mail: office@metalstechnology.co.uk
More informationProperties A Metal B Non- metal Electronic configuration?? Nature of oxides?? Oxidizing or reducing action?? Conduction of heat and electricity??
CLASS: X NCERT (CBSE) SCIENCE: Chemistry Page: 1 Question 1: Compare the properties of a typical metal and a non-metal on the basis of the following. Fill in Column A, B. Properties A Metal B Non- metal
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK B229 Contact: Ms Jill French Analytical Services Tel: +44 (0)19467 87408 Sellafield Fax: +44 (0)19467 75154 Cumbria E-Mail: jill.x.french@sellafieldsites.com
More informationGENARAL INTRODUCTION TO METALLURGY :Std: XI-CHEMISTRY
GENARAL INTRODUCTION TO METALLURGY :Std: XI-CHEMISTRY 1. What is matrix? The ore is generally associated with rock impurities like clay, sand etc. called gangue or matrix 2. What is mineral? The natural
More informationAP Chemistry Reaction Set
Class: Date: AP Chemistry Reaction Set 2009-2010 Other 1. Pure solid phosphorus (white form) is burned in air. (2002) 2. Sulfur dioxide gas is bubbled into distilled water. (2001) 3. A drop of potassium
More informationTest Report No. F690101/LF-CTSAYHA Issued Date : August 20, 2013 Page 1 of 5
Test Report No. F690101/LF-CTSAYHA13-05147 Issued Date : August 20, 2013 Page 1 of 5 To: 3M Korea 27-3, Yoido-dong Yeongdeungpo-gu Seoul Korea The following sample(s) was/were submitted and identified
More informationHow to Collect Your Water Sample and Interpret the Results for the Livestock Analytical Package
How to Collect Your Water Sample and Interpret the Results for the Livestock Analytical Package Bradley J. Austin, Dirk Philipp, Mike Daniels, and Brian E. Haggard Arkansas Water Resources Center University
More informationThe Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption
The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption Application Note Atomic Absorption Authors Douglas E. Shrader Lucinda M. Voth Lawrence A. Covick Introduction With the
More informationICP/ICP-MS Standards. High Purity Standards for ICP/ICP-MS
ICP/ICP-MS Fisher Brand AA/ICP MS Fisherbrand ICP/ICP-MS Catalog No. Catalog No. Concentrationion Size ml Concentration Size ml 36 102 7820 Aluminum 36 102 7821 Antimony 36 102 7823 Arsenic 36 102 7824
More informationB Moulding plant. A Clay-bonded sand
124 Assistance for decisions: Burnt-on sand 125 Assistance for decisions: Burnt-on sand A Clay-bonded sand B Moulding plant Examine lustrous carbon production Measure active carbon in moulding sand, examine
More informationHigh Early Strength. Low Alkali Content. Low Heat of Hyderation. Containerised Solutions
High Early Strength Low Alkali Content Low Heat of Hyderation Containerised Solutions CONTENTS 04-05 06-07 08-09 10-11 12-13 14 INTRODUCTION Tiger Cement Limited Ordinary Portland Cement OPC 42.5 Normal
More informationBLACK STURGEON LAKES WATER QUALITY MONITORING
BLACK STURGEON LAKES WATER QUALITY MONITORING 2017 REPORT Prepared by: Ryan Haines, B.Sc. Biologist and Project Management Kenora Resource Consultants Inc. Site 155, Compartment 14, RR #1 Kenora, ON P9N
More informationCHAPTER 3 METALS AND NON-METALS About 118 elements are known today. There are more than 90 metals, 22 non metals and a few metalloids. Sodium (Na), potassium (K), magnesium(mg), aluminium(al), calcium(ca),
More informationBarry Avenue Plating Inc. Chemical Processing
This certificate is granted and awarded by the authority of the Nadcap Management Council to: Barry Avenue Plating Inc 2210 Barry Ave 90064 United States This certificate demonstrates conformance and recognition
More informationRaad voor Accreditatie (Dutch Accreditation Council RvA) Accreditation of Reference Material Producers
Raad voor Accreditatie (Dutch Accreditation Council RvA) Accreditation of Reference Material Producers Document code: RvA-T034-UK Version 4, 01 mei 2013 A RvA-Explanatory note describes the policy and/or
More informationOutotec Hydrometallurgical Nickel Plants and Processes
Outotec Hydrometallurgical Plants and Processes Our expertise and experience provide the path to optimized solutions and complete plants for the production of highquality nickel, from a wide range of nickel
More informationDETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES
ENVIRONMENTAL ANALYSIS DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, 14543 & 13428 USING THE AGILENT 5100 ICP-OES Solutions for Your Analytical Business Markets and
More informationA M E R O P A. Fertilizers. presentation for ASBA Cargo Conference in Miami FL. 28 Sept 2017
A M E R O P A Fertilizers presentation for ASBA Cargo Conference in Miami FL 28 Sept 2017 Overview What are Chemical (N P K) Fertilizers? Fertilizer Market Outlook to 2021 (Supply and Demand) Global Fertilizer
More informationNutrient Management in Field Crops MSU Fertilizer Recommendations Crop*A*Syst 2015 Nutrient Management Training
Nutrient Management in Field Crops MSU Fertilizer Recommendations Crop*A*Syst 2015 Nutrient Management Training George Silva - silvag@msu.edu Eaton, Ingham, Barry and Livingston Counties 17 Essential Plant
More informationCANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT
CANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT WATER QUALITY ASSESSMENT OF Thompson River AT SPENCES BRIDGE (1984 24) Prepared by: L. G. Swain, P. Eng. B.C. Ministry of Environment Prepared
More information