H-FLEX CABLES 10/2017

Size: px
Start display at page:

Download "H-FLEX CABLES 10/2017"

Transcription

1 10/2017 H-FLEX CABLES CONTENTS H-FLEX PWR PUR 0,6/1kV...2 H-FLEX PWR C-PUR 0,6/1kV...6 H-FLEX CTL PUR 250V...10 H-FLEX CTL C-PUR 250V...12 H-FLEX INS PUR 250V...14 H-FLEX INS C-PUR 250V...16 TECHNICAL INFORMATION...18 MARINE AND OFFSHORE CABLES INDUSTRIAL CABLES OPTICAL FIBRE CABLES FLEXIBLE CABLES

2 20,6/1kV CABLES H-FLEX PWR PUR 0,6/1kV Unscreened power and control cable for flexible use 10/2017 DESIGN: HELKAMA specification 1. Conductor - stranded copper conductor 1,0-300mm 2 IEC 60228:2004 class5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic 3. Bedding - non-woven separator tape 4. Sheath - Polyurethane compound - standard colour black, other colours on request Flameretardant Oil & chemical Halogenfree Mud Application: The cable is intended for flexible, portable, movable applications. Applications such as ship to shore cable, outdoor cranes and various industrial applications.it is suitable for flexible applications in machineries, machine tools, robot technics and can be submersed into water. The cable has good mechanical characteristics, high tensile strength, is abrasion and to UV, chemicals, oil and other fluids. The cable can be coiled back and forth. Suitable to dragchain use. Mud according to NEK606. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature 90 C Flame-retardant IEC test for single insulated wire and cable Halogen-free IEC series Mechanical flex test EN conditions according to EN Oil resistancy EN conditions according to EN Operating temperature C fixed use C flexible use Mechanical Core identification Marine type approvals Min. bending radius - fixed: 4 x d < 25 mm < 6 x d - mobile: 6 x d < 25 mm < 8 x d - s-shape deflection: 15 x d < 25 mm < 20 x d Max. tensile load without strength members 15 N/mm 2 of phases copper cross section Color code for 1 4 (5 if PE conductor) core cable, number code for core cable. DNV-GL, BV and ABS Tel , fax , helkamabica.com Subject to change without prior notice. See latest updates on our webpage.

3 3 H-FLEX PWR PUR 0,6/1kV Part number Normal G - type Number of conductors & cross-section n x mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x1,0 5, x1,5 5, x2,5 6, x4 6, x6 7, x10 8, x16 9, x25 11, x35 12, x50 14, x70 16, x95 18, x120 20, x150 23, x185 25, x240 28, x300 32, x1,0 8, x1,5 8, x2,5 10, x4 11, x6 12, x10 14, x16 16, x25 21, x35 23, x50 26, x70 31, ,6/1kV CABLES 10/ x1,0 8, x1,5 9, x2,5 10, x4 11, x6 13, x10 15, x16 18, x25 22, x35 24, x50 28, x70 33, x95 37, x120 42, x150 47, x185 52, x240 59, x300 67, x1,0 9, x1,5 10, x2,5 11, x4 12, x6 14, x10 17, x16 19, x25 25, x35 27, x50 32, x70 37, x95 41, x120 46, x150 53, x185 59, x240 66, Table continues on next page

4 40,6/1kV CABLES H-FLEX PWR PUR 0,6/1kV Part number Normal G - type Number of conductors & cross-section n x mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x1,0 10, x1,5 11, x2,5 12, x4 14, x6 15, x10 19, x16 21, x25 27, x35 30, x50 35, x70 41, x95 46, x120 51, x150 59, x185 65, x1,0 11, x1,5 12, x2,5 13, / x1,0 11, x1,5 12, x2,5 13, x4 15, x6 17, x10 20, x16 24, x25 30, x1,0 14, x1,5 15, x2,5 17, x1,0 14, x1,5 16, x2,5 18, x1,0 15, x1,5 16, x2,5 19, x1,0 16, x1,5 17, x2,5 20, x1,0 17, x1,5 18, x2,5 21, x1,0 20, x1,5 22, x2,5 25, x1,0 21, x1,5 22, x2,5 26, Table continues on next page

5 5 H-FLEX PWR PUR 0,6/1kV Part number Normal G - type Number of conductors & cross-section n x mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x1,0 21, x1,5 23, x2,5 27, x1,0 23, x1,5 25, x2,5 29, x25+3x6 23, x35+3x6 25, x50+3x10 29, x70+3x16 33, x95+3x16 37, x120+3x25 42, x150+3x25 48, x185+3x35 53, x240+3x50 60, x300+3x50 67, ,6/1kV CABLES 10/2017

6 60,6/1kV CABLES H-FLEX PWR C-PUR 0,6/1kV Screened power and control cable for flexible use 10/2017 DESIGN: HELKAMA specification 1. Conductor - stranded copper conductor 1,0-300mm 2 IEC 60228:2004 class5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic 3. Bedding - non-woven separator tape 4. Screen - copper wire braid, coverage > 94% - tinned copper wire braid on request 5. Sheath - Polyurethane compound - standard colour black, other colours on request Flameretardant Oil & chemical Halogenfree Mud Application: The cable is intended for flexible, portable, movable applications. Applications such as ship to shore cable, outdoor cranes and various industrial applications.it is suitable for flexible applications in machineries, machine tools, robot technics and can be submersed into water. The cable has good mechanical characteristics, high tensile strength, is abrasion and to UV, chemicals, oil and other fluids. The cable can be coiled back and forth. Suitable to dragchain use. Mud according to NEK606. Main characteristics Rated voltage AC 0,6/1kV (1,2kV) DC 0,9/1,5kV (if voltage to earth does not exceed 0,9kV) Maximum conductor temperature 90 C Flame-retardant IEC test for single insulated wire Halogen-free IEC series Mechanical flex test EN conditions according to EN Oil resistancy EN conditions according to EN Operating temperature C fixed use C flexible use Mechanical Core identification Marine type approvals Min. bending radius - fixed: 4 x d < 25 mm < 6 x d - mobile: 8 x d < 25 mm < 10 x d - s-shape deflection: 15 x d < 25 mm < 20 x d Max. tensile load without strength members 15 N/mm 2 of phases copper cross section Color code for 1 4 (5 if PE conductor) core cable, number code for core cable. DNV-GL, BV and ABS Tel , fax , helkamabica.com Subject to change without prior notice. See latest updates on our webpage.

7 7 H-FLEX PWR C-PUR 0,6/1kV Part number Normal G - type Number of conductors & cross-section n x mm 2 Cross-section of screen mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x1,0 3,0 6, x1,5 3,0 6, x2,5 3,0 7, x4 3,1 7, x6 3,1 8, x10 3,6 9, x16 4,1 10, x25 4,8 12, x35 5,4 13, x50 6,3 15, x70 7,3 17, x95 8,2 19, x120 9,2 21, x150 10,2 24, x185 11,4 26, x240 12,7 30, x300 14,2 33, x1,0 3,6 9, x1,5 3,7 10, x2,5 4,2 11, x4 4,8 12, x6 5,4 13, x10 6,3 16, x16 7,4 18, x25 9,2 22, x35 10,4 24, x50 12,2 28, x70 14,2 32, ,6/1kV CABLES 10/ x1,0 3,6 10, x1,5 4,1 10, x2,5 4,5 11, x4 5,3 13, x6 5,8 14, x10 6,8 16, x16 8,0 19, x25 9,9 24, x35 11,3 25, x50 13,2 30, x70 15,3 34, x95 17,4 38, x120 19,5 43, x150 21,5 49, x185 24,1 54, x240 26,9 61, x300 30,2 68, x1,0 4,1 10, x1,5 4,4 11, x2,5 5,2 12, x4 5,7 14, x6 6,4 15, x10 7,8 18, x16 8,9 21, x25 11,0 26, x35 12,6 28, x50 14,6 33, x70 16,9 38, x95 19,5 42, x120 21,5 48, x150 24,3 54, x185 26,7 60, x240 30,6 68, Table continues on next page

8 80,6/1kV CABLES H-FLEX PWR C-PUR 0,6/1kV Part number Normal G - type Number of conductors & cross-section n x mm 2 Cross-section of screen mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x1,0 4,4 11, x1,5 4,9 12, x2,5 5,5 13, x4 6,3 15, x6 7,1 16, x10 8,4 20, x16 9,9 23, x25 12,2 29, x35 14,1 31, x50 16,4 36, x70 18,8 42, x95 21,4 47, x120 24,1 53, x150 26,8 60, x1,0 4,7 12, x1,5 5,4 13, x2,5 6,1 14, / x1,0 4,9 12, x1,5 5,4 13, x2,5 6,1 14, x4 7,8 16, x6 7,9 18, x10 9,3 22, x16 10,9 25, x25 13,6 31, x1,0 6,5 15, x1,5 7,2 16, x2,5 8,2 18, x1,0 6,8 16, x1,5 7,5 17, x2,5 8,5 19, x1,0 7,1 16, x1,5 7,9 18, x2,5 9,0 20, x1,0 7,8 17, x1,5 8,4 19, x2,5 9,5 21, x1,0 8,0 18, x1,5 8,9 19, x2,5 10,1 22, x1,0 9,7 21, x1,5 10,7 23, x2,5 12,1 26, x1,0 9,9 22, x1,5 11,0 24, x2,5 12,5 27, Table continues on next page

9 9 H-FLEX PWR C-PUR 0,6/1kV Part number Normal G - type Number of conductors & cross-section n x mm 2 Cross-section of screen mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x1,0 10,3 22, x1,5 11,4 25, x2,5 13,0 28, x1,0 11,2 24, x1,5 12,4 26, x2,5 14,1 30, x25+3x6 13,0 24, x35+3x6 14,8 26, x50+3x10 17,2 30, x70+3x16 20,0 35, x95+3x16 22,5 39, x120+3x25 34,8 44, x150+3x25 39,1 50, x185+3x35 43,1 55, x240+3x50 48,7 62, x300+3x50 53,2 69, ,6/1kV CABLES 10/2017

10 10 250V CABLES H-FLEX CTL PUR 250V Unscreened control cable for flexible use 10/2017 DESIGN: HELKAMA specification 1. Conductor - stranded copper conductor IEC 60228:2004 class5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic 3. Bedding - separator tape 4. Sheath - Polyurethane compound - standard colour black, other colours on request Flameretardant Oil & chemical Halogenfree Mud Application: The cable is intended for flexible, portable, movable applications. Applications such as ship to shore cable, outdoor cranes and various industrial applications.it is suitable for flexible applications in machineries, machine tools, robot technics and can be submersed into water. The cable has good mechanical characteristics, high tensile strength, is abrasion and to UV, chemicals, oil and other fluids. The cable can be coiled back and forth. Suitable to dragchain use. Mud according to NEK606. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature 90 C Flame-retardant IEC test for single insulated wire and cable Halogen-free IEC series Mechanical flex test EN conditions according to EN Oil resistancy EN conditions according to EN Operating temperature C fixed use C flexible use Mechanical Min. bending radius - fixed: 4 x d < 25 mm < 6 x d - mobile: 6 x d < 25 mm < 8 x d - s-shape deflection: 15 x d < 25 mm < 20 x d Max. tensile load without strength members 15 N/mm 2 of phases copper cross section Core identification Marine type approvals White insulation with black numbers DNV-GL, BV and ABS Tel , fax , helkamabica.com Subject to change without prior notice. See latest updates on our webpage.

11 11 H-FLEX CTL PUR 250V Part number Normal G - type Number of conductors & cross-section n x mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x0,5 6,0 35 8, x0,5 6,5 40 7, x0,5 7,0 50 6, x0,5 8,0 60 6, x0,5 8,0 70 5, x0,5 10, , x0,5 11, , x0,5 11, , x0,5 12, , x0,5 12, , x0,5 12, , x0,5 14, , x0,5 15, , x0,5 15, , x0,5 17, , x0,75 7, , x0,75 7,0 50 9, x0,75 7,5 65 8, x0,75 9,0 80 8, x0,75 9,0 95 7, x0,75 12, , x0,75 12, , x0,75 13, , x0,75 14, , x0,75 14, , x0,75 14, , x0,75 16, , x0,75 17, , x0,75 17, , x0,75 19, ,3 250V CABLES 10/2017

12 12 250V CABLES H-FLEX CTL C-PUR 250V Screened control cable for flexible use 10/2017 DESIGN: HELKAMA specification 1. Conductor - stranded copper conductor IEC 60228:2004 class5 - tinned stranded copper conductor on request 2. Insulation - XLPE plastic 3. Bedding - separator tape 4. Screen - copper wire braid, coverage > 94% - tinned copper wire braid on request 5. Sheath - Polyurethane compound - standard colour black, other colours on request Flameretardant Oil & chemical Halogenfree Mud Application: The cable is intended for flexible, portable, movable applications. Applications such as ship to shore cable, outdoor cranes and various industrial applications.it is suitable for flexible applications in machineries, machine tools, robot technics and can be submersed into water. The cable has good mechanical characteristics, high tensile strength, is abrasion and to UV, chemicals, oil and other fluids. The cable can be coiled back and forth. Suitable to dragchain use. Mud according to NEK606. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature 90 C Flame-retardant IEC test for single insulated wire and cable Halogen-free IEC series Mechanical flex test EN conditions according to EN Oil resistancy EN conditions according to EN Operating temperature C fixed use C flexible use Mechanical Core identification Marine type approvals Min. bending radius - fixed: 4 x d < 25 mm < 6 x d - mobile: 6 x d < 25 mm < 8 x d - s-shape deflection: 15 x d < 25 mm < 20 x d Max. tensile load without strength members 15 N/mm 2 of phases copper cross section White insulation with black numbers DNV-GL, BV and ABS Tel , fax , helkamabica.com Subject to change without prior notice. See latest updates on our webpage.

13 13 H-FLEX CTL C-PUR 250V Part number Normal G - type Number of conductors & cross-section n x mm 2 Cross-section of screen mm 2 Nominal outer diameter mm Approximate weight kg/km Current Rating A x0,5 3,5 7,5 70 8, x0,5 3,6 7,5 80 7, x0,5 3,6 8,0 85 6, x0,5 3,6 9, , x0,5 3,6 9, , x0,5 4,4 11, , x0,5 4,5 12, , x0,5 4,8 12, , x0,5 5,3 13, , x0,5 5,3 13, , x0,5 5,9 13, , x0,5 6,5 16, , x0,5 6,6 16, , x0,5 6,9 17, , x0,5 7,4 18, , x0,75 3,6 8, , x0,75 3,6 8,0 90 9, x0,75 3,6 9, , x0,75 3,7 10, , x0,75 4,1 10, , x0,75 5,3 13, , x0,75 5,4 13, , x0,75 5,7 14, , x0,75 6,2 15, , x0,75 6,4 15, , x0,75 6,9 15, , x0,75 7,7 18, , x0,75 7,9 18, , x0,75 8,2 19, , x0,75 8,9 20, ,3 250V CABLES 10/2017

14 14 250V CABLES H-FLEX INS PUR 250V Unscreened instrumentation and control cable for flexible use 10/2017 DESIGN: HELKAMA specification 1. Conductor - stranded copper conductor IEC 60228:2004 class5 tinned stranded copper conductor on request Insulation - XLPE plastic 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Sheath - Polyurethane compound - standard colour black, other colours on request Flameretardant Oil & chemical Halogenfree Mud Application: The cable is intended for flexible, portable, movable applications. Applications such as ship to shore cable, outdoor cranes and various industrial applications.it is suitable for flexible applications in machineries, machine tools, robot technics and can be submersed into water. The cable has good mechanical characteristics, high tensile strength, is abrasion and to UV, chemicals, oil and other fluids. The cable can be coiled back and forth. Suitable to dragchain use. Mud according to NEK606. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature 90 C Flame-retardant IEC test for single insulated wire and cable Halogen-free IEC series Mechanical flex test EN conditions according to EN Oil resistancy EN conditions according to EN Mechanical Min. bending radius - fixed: 4 x d < 25 mm < 6 x d - mobile: 6 x d < 25 mm < 8 x d - s-shape deflection: 15 x d < 25 mm < 20 x d Max. tensile load without strength members 15 N/mm 2 of phases copper cross section Operating temperature C fixed use C flexible use Core identification Marine type approvals White and blue insulation with black numbers DNV-GL, BV and ABS Tel , fax , helkamabica.com Subject to change without prior notice. See latest updates on our webpage.

15 H-FLEX INS PUR 250V Part number Normal Number of conductors & cross-section n x mm 2 Cross-section of screen mm 2 Nominal outer diameter mm Approximate weight kg/km x2x0,5 0,4 7, x3x0,5 0,5 7, x4x0,5 0,5 8, x2x0,5 0,7 10, x2x0,5 0,8 10, x2x0,5 0,9 11, x2x0,5 1,1 13, x2x0,5 1,2 14, x2x0,5 1,4 16, x2x0,5 1,4 17, x2x0,5 1,5 18, x2x0,5 1,6 19, x2x0,5 1,8 20, x2x0,5 2,0 22, x2x0,5 2,1 24, x2x0,5 2,2 25, x2x0,5 2,3 25, x2x0,5 2,5 27, x2x0,75 0,5 8, x3x0,75 0,5 8, x4x0,75 0,6 9, x2x0,75 0,8 11, x2x0,75 0,9 12, x2x0,75 1,0 13, x2x0,75 1,3 15, x2x0,75 1,4 16, x2x0,75 1,6 18, x2x0,75 1,7 19, x2x0,75 1,8 20, x2x0,75 1,9 21, x2x0,75 2,1 23, x2x0,75 2,3 26, x2x0,75 2,5 27, x2x0,75 2,6 28, x2x0,75 2,7 29, x2x0,75 2,9 31, V CABLES 10/ x2x1,5 0,7 10, x3x1,5 0,7 10, x4x1,5 0,8 11, x2x1,5 1,2 14, x2x1,5 1,2 15, x2x1,5 1,4 16, x2x1,5 1,7 19, x2x1,5 1,9 21, x2x1,5 2,2 24, x2x1,5 2,3 25, x2x1,5 2,4 27, x2x1,5 2,6 28, x2x1,5 2,8 30, x2x1,5 3,2 34, x2x1,5 3,4 36, x2x1,5 3,6 38, x2x1,5 3,7 39, x2x1,5 4,0 41, x2x2,5 0,8 11, x3x2,5 0,9 11, x4x2,5 1,0 12, x2x2,5 1,3 16, x2x2,5 1,4 17, x2x2,5 1,6 19, x2x2,5 2,0 22, x2x2,5 2,2 24, x2x2,5 2,5 27, x2x2,5 2,6 29, x2x2,5 2,9 31, x2x2,5 3,1 33, x2x2,5 3,3 35, x2x2,5 3,7 39, x2x2,5 4,0 41, x2x2,5 4,2 44, x2x2,5 4,3 45, x2x2,5 4,6 48,0 2850

16 16 250V CABLES H-FLEX INS C-PUR 250V Screened instrumentation and control cable for flexible use 10/2017 DESIGN: HELKAMA specification 1. Conductor - stranded copper conductor IEC 60228:2004 class5 tinned stranded copper conductor on request 2. Insulation - XLPE plastic 3. Twisted pair - two insulated cores twisted together to form a pair See next page for Quad 4. Screen - copper wire braid, coverage > 94% 5. Sheath - Polyurethane compound - standard colour black, other colours on request Flameretardant Oil & chemical Halogenfree Mud Application: The cable is intended for flexible, portable, movable applications. Applications such as ship to shore cable, outdoor cranes and various industrial applications.it is suitable for flexible applications in machineries, machine tools, robot technics and can be submersed into water. The cable has good mechanical characteristics, high tensile strength, is abrasion and to UV, chemicals, oil and other fluids. The cable can be coiled back and forth. Suitable to dragchain use. Mud according to NEK606. Main characteristics Rated voltage 150/250V (300V) Maximum conductor temperature 90 C Flame-retardant IEC test for single insulated wire and cable Halogen-free IEC series Mechanical flex test EN conditions according to EN Oil resistancy EN conditions according to EN Mechanical Min. bending radius - fixed: 4 x d < 25 mm < 6 x d - mobile: 8 x d < 25 mm < 10 x d - s-shape deflection: 15 x d < 25 mm < 20 x d Max. tensile load without strength members 15 N/mm 2 of phases copper cross section Operating temperature C fixed use C flexible use Core identification Marine type approvals White and blue insulation with black numbers DNV-GL, BV and ABS Tel , fax , helkamabica.com Subject to change without prior notice. See latest updates on our webpage.

17 H-FLEX INS C-PUR 250V Part number Normal Number of conductors & cross-section n x mm 2 Nominal outer diameter mm Approximate weight kg/km x2x0,5 6, x3x0,5 6, x4x0,5 7, x2x0,5 9, x2x0,5 9, x2x0,5 10, x2x0,5 12, x2x0,5 13, x2x0,5 15, x2x0,5 15, x2x0,5 16, x2x0,5 17, x2x0,5 19, x2x0,5 21, x2x0,5 22, x2x0,5 23, x2x0,5 24, x2x0,5 26, x2x0,75 7, x3x0,75 7, x4x0,75 7, x2x0,75 10, x2x0,75 10, x2x0,75 11, x2x0,75 14, x2x0,75 15, x2x0,75 17, x2x0,75 18, x2x0,75 19, x2x0,75 20, x2x0,75 22, x2x0,75 24, x2x0,75 26, x2x0,75 27, x2x0,75 28, x2x0,75 29, V CABLES 10/ x2x1,5 8, x3x1,5 9, x4x1,5 10, x2x1,5 13, x2x1,5 14, x2x1,5 15, x2x1,5 18, x2x1,5 20, x2x1,5 23, x2x1,5 24, x2x1,5 25, x2x1,5 27, x2x1,5 29, x2x1,5 33, x2x1,5 35, x2x1,5 36, x2x1,5 38, x2x1,5 40, x2x2,5 10, x3x2,5 10, x4x2,5 11, x2x2,5 15, x2x2,5 15, x2x2,5 17, x2x2,5 21, x2x2,5 23, x2x2,5 26, x2x2,5 27, x2x2,5 29, x2x2,5 31, x2x2,5 34, x2x2,5 38, x2x2,5 40, x2x2,5 42, x2x2,5 44, x2x2,5 46,5 2575

18 18 TECHNICAL INFORMATION TECHNICAL INFORMATION Additional tests: Electrical data: Acid gas emission test according to IEC :2011. ph and conductivity test according to IEC :2011. Fluorine content test according to IEC :2003. Mechanical flexing test according to EN part 6.2 Mechanical bending test ongoing, 2,5 M bends H-FLEX INS PUR 250V Loop resistance of pair, max. / +20 C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20 C 0,5mm 2 0,75mm 2 1,5mm 2 Unit ,4 ohm/km nf/km 0,6 0,6 0,7 mh/km Mohm/km 10/2017 H-FLEX INS C-PUR 250V Loop resistance of pair, max. / +20 C Pair capacitance, nom. / 800Hz Loop inductance, nom. Insulation resistance / +20 C 0,5mm 2 0,75mm 2 1,5mm 2 Unit ,4 ohm/km nf/km 0,6 0,6 0,7 mh/km Mohm/km Oil resistance: Sheathing material is oil according to method EN and requirements from EN The oil resistance is demonstrated by immersion in mineral oil IRM902 for one week at 100 C. Mud resistance: Sheathing material is mud according to NEK 606 requirements. Mud resistance is demonstrated by immersion in different types of drilling fluids for 56 days in 70 C. Chemical performance: Chemical & oil resistance: Excellent Grease & mineral oils resistance: Excellent Diesel oil resistance: Excellent Kerosene resistance: Excellent Petrol resistance, standard grade: Excellent Glycol resistance: Excellent Water performance: Water resistance: AD8 Submersion in salt and fresh water up to 500m. IEC test IEC is the test for single insulated wire and cable. Test procedure and requirements according to the picture below. 50 mm mm mm mm Min. 50 mm of the cable, measured from the upper support, must remain unburned after the specified time.

19 Diameter tolerance: Cable outer diameter, mm. Tolerance 1 10 ±0,5mm 10,1 20 ±1,0mm 20,1 30 ±1,5mm Cable outer diameter, mm. Tolerance 30,1 40 ±2,0mm 40,1 50 ±2,5mm 50,1 60 ±3,0mm Factory recognition: Marking on the sheath LOT ##### H-FLEX (+type) "number of core" x "size of conductor" mm 2 0,6/1kV + 90 C HELKAMA "month-year" and "length marking". LOT ##### H-FLEX (+type) "number of core" x "size of conductor" mm 2 250V + 90 C HELKAMA "month-year" and "length marking". Subject to change without prior notice. See latest updates on our webpage helkamabica.com

20 HELKAMA BICA OY Lakimiehenkatu 4 FI KAARINA Finland Tel Fax firstname.lastname@helkamabica.fi sales@helkamabica.fi Helkama Bica (Shanghai) Co., Ltd. Plot 1-2, MinHang Export Processing Zone No Huan Cheng West Road Fengxian District, Shanghai , China Tel , Fax sales@helkamabica.cn helkamabica.com

Construction guideline

Construction guideline 1/6 1) SUMMARY OF ABBREVIATIONS FOR CABLE CONSTRUCTION ELEMENTS MSR - : EUPEN code for INSTRUMENTATION CABLES JE - : cable for INDUSTRIAL ELECTRONICS RD - : cable for CONTROL SYSTEMS INSULATION MATERIALS:

More information

The Company by Peter Bröckskes sen. an independent, middle sized company

The Company by Peter Bröckskes sen. an independent, middle sized company The Company DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business a company with nearly 500 staff

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

Reeling Cables www.sab-worldwide.com THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control technique as well as in cable production have made a one man business

More information

Armoured Instrumentation Cables to BS7917

Armoured Instrumentation Cables to BS7917 Armoured Instrumentation Cables to BS1 Fire Resistant, Pairs/Triples - Collectively Screened. Low Smoke Zero Halogen TAC, MGT, EPR, SCRN, ZH, GSWB, SW 0/0V Application Control and instrumentation cable

More information

Single core conductor BETAtherm 145

Single core conductor BETAtherm 145 Internet: www.synflex.de Single core conductor BETAtherm 145 Description BETAtherm 145 is a flexible low-voltage cable with UL recognition consisting of a tinned copper stranded wire and insulated with

More information

etwork etwork-/ethernet-/foc-cable

etwork etwork-/ethernet-/foc-cable etwork etwork-/ethernet-/foc-cable Chainflex eadycable Network-/Ethernet-/FOC-cable Cable type Jacket Page CFLG.6G Gradient fiber glass cable TPE 226 CFLG.12G Gradient fiber glass cable TPE 228 CAT5 Ethernet

More information

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. 37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),

More information

Instrumentation Cables

Instrumentation Cables Instrumentation Cables Product Catalogue Factories and Regional Offices Tai Sin Electric Limited 24 Gul Crescent Jurong Town Singapore 62953 Tel: (+65) 6672 9292 Fax: (+65) 686 4084 E-Mail: sales@taisin.com.sg

More information

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics ENERGY PROTOLON(SMK) LWL (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics Technical Data Type Type designation Approvals/ standards Application PROTOLON (SMK) LWL (N)TSKCGEWÖU DIN

More information

Cables for Drag Chains

Cables for Drag Chains HELUKABEL Products are available from MARYLAND METRICS P.O. Box 21 Owings Mills, MD 211 USA web: http://mdmetric.com ph: (4)35-3130 (00)3-30 fx: (4)35-32 (00)72-9329 email: sales@mdmetric.com RFQ form:

More information

U.V resistance UL Sunlight Resistance. Flame retardant IEC

U.V resistance UL Sunlight Resistance. Flame retardant IEC Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial

More information

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification

More information

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover

More information

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES 11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE

More information

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN Engineering Specification Electrical Networks MESP 030000-04 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN Version: 1 Issued:

More information

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths Datasheet ENGLISH Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths High temperature, rugged, flexible Pt100 probe Suitable

More information

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152

PT. KABELINDO MURNI Tbk SHIPBOARD CABLE WIRE AND CABLE MANUFACTURER. No. EMS No. OSH No. QCS 00152 PT. KABELINDO MURNI Tbk WIRE AND CABLE MANUFACTURER No. QCS 00152 No. OSH 00971 No. EMS 00151 Introduction of company The Company s history was marked by the founding of PT. Kabel Indonesia (Kabelindo)

More information

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems. PHOTOVOLTAIC CABLES Energy and Fiber Optical Cables for Solar Energy Systems. As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of

More information

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NPS/002/020 Technical Specification for 11 & 20kV Power Cables Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements

More information

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11

BUS CABLES. Content. IBL 600 PVC Interbus-Loop cable... E/11. S IBL 605 PUR Interbus-Loop cable for cable tracks... E/11 Bus Cables BUS CABLS Content page Applications... /5-6 Interbus-S cables remote bus cables IBS 612 PVC Interbus-S cable for indoor and outdoor installation... /7 IBS 617 PVC Interbus-S cable with UL recognition...

More information

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEB SPECIFICATION 005-1: 2012 P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS PAGE 1. Scope 03

More information

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal) ENGLISH Datasheet Platinum Resistance Pt100 Wire-Wound Detector Elements Pt100 platinum resistance thermometer elements in a choice of sizes single & dual element Pt100 elements to IEC 60751 Class A or

More information

P.V.C. INSULATED UNARMOURED COPPER CABLES

P.V.C. INSULATED UNARMOURED COPPER CABLES 083 : 2007 CEB SPECIFICATION P.V.C. INSULATED UNARMOURED COPPER CABLES CEYLON ELECTRICITY BOARD SRI LANKA Specification for P.V.C. INSULATED UNARMOURED COPPER CABLES CEB Specification 083 : 2007 CEYLON

More information

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm) Pt100 Elements, Thin Film (100 Ohm) Pt100 elements to IEC751 Class A,

More information

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code Datasheet Platinum Resistance Pt100 Tubular Ceramic Insert Elements with tail wires 2 or 4 wire with choice of Teflon or nickel/glassfibre insulated tail wires up to 450mm long ENGLISH 237-1635 237-1641

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS PAGODA CABLES PVT. LTD. 1/58, STREET NO: 3, VISHWAS NAGAR, SHAHDARA, DELHI 110 032. (INDIA) TEL/FAX : 91-11-22392801, 22385391. Email : pagoda @del2.vsnl.net.in CONTENTS: 1. 2.

More information

Engineering Data for Copper and Aluminum Conductor Electrical Cables

Engineering Data for Copper and Aluminum Conductor Electrical Cables 2018 Edition Engineering Data for Copper and Aluminum Conductor Electrical Cables THE OKONITE COMPANY Okonite Cables...A higher Standard! The Okonite Company, 2018 Okonite Cables Table of Contents SECTION

More information

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation Product Classification E 2 O E2O540JCASS-24CT 24CT MICFIBR-12.7MB DUCT E 2 O Coaxial/Fiber/Microduct Hybrid Buried Cable E 2 O is a solution that enables service providers the ability to bridge HFC networks

More information

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 14572 Second edition 2006-11-15 Road vehicles Round, screened and unscreened 60 V and 600 V multi-core sheathed cables Test methods and requirements for basic and high-performance

More information

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead (Image shows 4 wire) Pt1000 element to IEC 751 Class B 2 wire configuration Temperature range -50 C to + 200 C Pt1000

More information

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths ENGLISH Duplex PRT s with two independent PT100 detectors inside tip of probe. This

More information

Landguard VG Land forces wire and cable to the VG specification

Landguard VG Land forces wire and cable to the VG specification Land forces wire and cable to the VG specification Contents Page H-GM20-A Single core VG 95218-T020A 3 ETFE H-GM21-E Twisted pair / triple / quad VG 95218-T021E 4 H-GM22-C VG 95218-T022C 5 ETFE Shielded

More information

ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME. Technical Specification (T.S)

ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME. Technical Specification (T.S) ACCELARATED POWER DEVELOPMENT AND REFORM PROGRAMME SECTION - V Technical Specification (T.S) 37 (SCHEDULE I) TECHNICAL SPECIFICATION FOR SUPPLY OF AB CABLE 38 1. SCOPE: TECHNICAL SPECIFICATION This specification

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- T/0018/ DMRC-E-TR-CABLE-2 SPECIFICATIONS FOR 33 kv CABLES FOR ELEVATED AND Issued on: Date Stage

More information

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing

Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Datasheet ENGLISH Platinum Resistance Pt100 & Pt1000 Silicone Patch Sensors Element Encapsulated in A Silicone Rubber Patch with Self-Adhesive Aluminium Foil Backing Pt100 Patch Sensor (100 Ω Ohms @ 0

More information

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED WITH METALLIC SCREEN Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM CONDUCTOR 1.9kV XLPE INSULATED Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead Datasheet Platinum Resistance Pt100 Sheathed Thin Film Strip Sensor 2 wire sensor sheathed in a thin stainless steel shim body ideal for surface measurement ENGLISH Sheathed Pt100 element in a thin, flat

More information

Insulation in decks and bulkheads PYROLIQ sealing compound system

Insulation in decks and bulkheads PYROLIQ sealing compound system Insulation in decks and bulkheads PYROLIQ sealing compound system PYROLIQ casting compound In industry, ship construction and offshore areas, very high requirements are placed on cable and pipe penetrations

More information

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves ENGLISH Datasheet Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves Pt100 Autoclave & steriliser drain temperature probe For use to monitor the fluid

More information

7. EXTENSION LEADS AND COMPENSATING CABLE

7. EXTENSION LEADS AND COMPENSATING CABLE 7. EXTENSION LEADS AND COMPENSATING CABLE 7.1 INTRODUCTION : It is often desirable to connect a thermocouple probe, as a part of a very long circuit from the sensor itself to a remote reference unit and/or

More information

Cable solutions for Automation & Drives

Cable solutions for Automation & Drives www.leoni-industrial-solutions.com Cable solutions for Automation & Drives The Quality Connection Issue 11/2016 All FieldLink products are permanently enhanced for our customers. Therefore this brochure

More information

Electrical Insulating Tapes

Electrical Insulating Tapes Electrical Insulating Tapes Energy, Mining, Industrial and Contractors applications LV and MV electrical jointing and termination applications Adhesive or Self-amalgamating UV resistant Cold and weather

More information

*** Supercedes: BECO E and COM , , & ***

*** Supercedes: BECO E and COM , , & *** 7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single

More information

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting

ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting ENGLISH Datasheet Platinum Resistance Pt100 Hygienic Thermometer, 1.5'' RJT style fitting RJT unions (Ring Joint Type) are often referred to as a standard union. The compromise of an O-ring style gasket

More information

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING PRICE LIST NO: FCL/IW.11.17/05 HSN CODE:85 FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL CABLES WITH FLAME RETARDANT PROPERTIES &

More information

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6 CONTENT page < The company............................................................................... 3 < W - worldwide...............................................................................

More information

Fibre optic cables CTC LSZH 1,2kN

Fibre optic cables CTC LSZH 1,2kN CTC LSZH,kN CTC LSZH,kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-2 Second edition 2005-03 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 2: Cables

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

Cast resin joint for paper- and plastic insulated cables for low voltage applications till 0,6/1 (1,2) kv.

Cast resin joint for paper- and plastic insulated cables for low voltage applications till 0,6/1 (1,2) kv. Cast resin joints Straight connection joint various sizes Cast resin joint for paper- and plastic insulated cables for low voltage applications till 0,6/1 (1,2) kv. Application: Underground, above ground,

More information

Cables for Railway Signalling Applications General Requirements

Cables for Railway Signalling Applications General Requirements Discipline: Engineering (Signalling) Category: Procedure Cables for Railway Signalling Applications General Requirements ESA-11-01 Applicability ARTC Network Wide Primary Source ESA-02-01 Document Status

More information

AN ISO 9001 : 2008 COMPANY

AN ISO 9001 : 2008 COMPANY Win ding WiresFo rsubmersi ble Pumps &Motors AN ISO 91 : 28 COMPANY Winding Wires For Submersible Pumps & Motors We are engaged in manufacturing of polyester & polypropylene taped submersibles winding

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating

More information

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable Corning Cable 229.5012 Industrial LSZH Loose Tube, Gel-Free, Corning Cable Systems Industrial LSZH Fiber Optic Cables are designed for industrial building backbones and harsh environments atypical of traditional

More information

Amphenol Spectra-Strip

Amphenol Spectra-Strip 161 Series Fiber Optic Cable for Harsh Environments 1 are subject to change without notice. Introduction Amphenol Corporation is a world leader in harsh environment Interconnect systems. The Spectra-Strip

More information

Hose protection. Hose protection. Edition: 02/2008 Catalogue 1

Hose protection. Hose protection. Edition: 02/2008 Catalogue 1 Hose protection Edition: 02/2008 Catalogue 1 12 Note All the information in this catalogue is based on the standards applicable at the time of publication and the regulations of the employers liability

More information

NPS/002/023 Technical Specification for 132kV Power Cables.

NPS/002/023 Technical Specification for 132kV Power Cables. Version:- 2.2 of Issue:- June 09 Page 1 of 11 NPS/002/023 Technical Specification for 132kV Power Cables. 1. Purpose The purpose of this document is to detail the technical requirements of Northern Powergrid

More information

Flygt 3171, 50Hz. Technical Specification

Flygt 3171, 50Hz. Technical Specification Flygt 3171, 50Hz Technical Specification Table of Contents Table of Contents F-pump, Standard Motor...2 Product description...2 Motor rating and performance curves...5 F-pump, Premium Efficiency Motor

More information

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00. To: National Cables Industry P.O Box 27472 Al Dhaid Road, Al Sajja Industrial Area Sharjah U.A.E TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE Kinectrics International Inc. Report No.: K-422341-RC-0001-R00

More information

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable Ergon Energy Corporation Limited Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable ETS04-03-01 Specification ETS04-03-01 Ver 1 Contents 1. Purpose and Scope... 1 1.1 General...

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Related Documents: No.10 for Fiber Optic Cables.pdf Cable Characteristics: DESCRIPTION: 4 to 36 optical fibers, Gel filling loose tubes

More information

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified Your Partner for Custom Interconnectivity Solutions ISO 9001 AS9100C ISO 13485 ISO 17025 Qualified LEMO Precision Custom Connection Solutions The Original Push-Pull Connector Seven Decades of Expertise

More information

Single-Jacketed Tubing

Single-Jacketed Tubing Single-Jacketed Tubing COILED STICK CUT TO LENGTH UTC Single Jacketed tube Protect the tube against corrosion and pitting in a diverse changing environment and climates. The phenomenon of Chloride Stress

More information

Una e mpre sa Vi akab l e GLOSSARY.

Una e mpre sa Vi akab l e GLOSSARY. GLOSSARY www.centelsa.com.co CONDUCTORS Cu Copper conductors. CuSn Tinned copper conductor. ACDSR Rectangular soft bare copper wire. ACDSRP Paper insulated rectangular soft bare copper wire. ACDD Bare

More information

Ministry of Defence Defence Standard 61-12(Part 26)

Ministry of Defence Defence Standard 61-12(Part 26) Ministry of Defence Defence Standard 61-12(Part 26) Issue 3 Publication Date 27 January 2001 Wires, Cords and Cables, Electrical Part 26: Wires, and Cables Electrical, Dual Extruded Insulation Type Olefin/vinylidene-Fluoride

More information

Specifications of. Single Armored Optical Fiber Cable

Specifications of. Single Armored Optical Fiber Cable SPEC. NO A15022701 Sheet no.1 of 7 Date: 15-02-27 Specifications of Single Armored Optical Fiber Cable (GYFTS) 1. General SPEC.NO A15022701 Sheet No.2 of 7 1.1 This specification covers the requirements

More information

SECTION WIRES AND CABLES

SECTION WIRES AND CABLES SECTION 16120 PART 1 - GENERAL 1.01 DESCRIPTION A. The work to be performed includes, but is not necessarily limited to, all work involved with the supply and installation of wires and cables and the associated

More information

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE SEAL & SIGNATURE OF THE TENDERER PAGE 1 OF 14 TECHNICAL SPECIFICATION FOR LT XLPE POWER CABLES (SPECIFICATION NO.MM/I/LTXLPE/2006) 1. SCOPE: The specification

More information

FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES

FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES FURUKAWA ELECTRIC TAPE FOR ELECTRICAL USES FURUKAWA ELECTRIC TAPE LIVING OUR ADVANCED TECHNOLOGIES Every type of Furukawa Electric tape is a high-quality tape manufactured utilizing the long years of electric

More information

SECTION INSULATED WIRE AND CABLE

SECTION INSULATED WIRE AND CABLE SECTION 16120 INSULATED WIRE AND CABLE PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Insulated Wire and Cable, which includes the following items with accessories, and appurtenances:

More information

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU INCH-POUND MIL-DTL-24643/17F 1 October 2009 SUPERSEDING MIL-DTL-24643/17E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU This specification is approved

More information

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials.

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials. LightScope ZWP Single Alternative Jacket All-Dielectric, Gel-Filled, Outdoor Stranded Loose Tube Cable Product Classification Portfolio CommScope Product Type Fiber OSP cable Regional Availability Asia

More information

Accelerated Aging Tests for MV Cables

Accelerated Aging Tests for MV Cables Accelerated Aging Tests for MV Cables Educational Session Fall ICC 2011 Denver, CO Acknowledgments: Rick Hartlein-NEETRAC Lauri Hiivala - Teksavvy Ram Ramachandran Dow Electrical & Telecommunications Dow

More information

Nofirno Multi Cable and Pipe Transits The latest fire test procedures for AO & HO multi cable transits and pipe penetrations

Nofirno Multi Cable and Pipe Transits The latest fire test procedures for AO & HO multi cable transits and pipe penetrations Nofirno Multi Cable and Pipe Transits The latest fire test procedures for AO & HO multi cable transits and pipe penetrations CSD Sealing Systems are the UK market leaders in the supply of cable and pipe

More information

FTTH Fiber Optical Cable

FTTH Fiber Optical Cable FTTH Optical Cable FTTH Drop Cables are designed to connect the fiber access point to the ONT on the home in a FTTH network. It offers an efficient and economical solution for deploying fiber in FTTH network.

More information

Introduction. Cable Assembly Solutions

Introduction. Cable Assembly Solutions Introduction Cable Assembly Solutions Epec Engineered Technologies is a highly regarded supplier of cable assemblies used in a wide variety of markets including Medical, Industrial, Automotive, and Data

More information

Rev. Aug 2017 valid until next revision

Rev. Aug 2017 valid until next revision WIRE&CABLE Disclaimer: - The applications specified for reference only. - It is customer s responsibilities to inspect and test the product for suitability of the customer s own use and purpose. The customer

More information

OPTICAL FIBRE CABLE PERFORMANCE

OPTICAL FIBRE CABLE PERFORMANCE WWW.northeastbroadband.com TEL: 1-888-908-0386 FAX: 1-888-568-9603 Specification Sheet Page:- 1 of 2 Single Mode Optical Sterlite ITU.T - G.652 D Maximum Cabled Attenuation db/km 1310nm : 0.35 & 1550nm

More information

Thermal Cutouts. Current sensitive thermal protection for coils/windings

Thermal Cutouts. Current sensitive thermal protection for coils/windings Thermal Cutouts Current sensitive thermal protection for coils/windings FEATURES broad product range for numerous applications rhomboid shape small size good pressure resistance high switching capacity

More information

Electrical Conductors

Electrical Conductors Electrical Conductors Course No: E02-005 Credit: 2 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com

More information

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE) Profile No.: 4 NIC Code: 27320 ELECTRICAL CABLES (SINGLE AND MULTICORE) 1. INTRODUCTION: Electrical Cables and wires are used for power distribution in electrical systems in housing sector as well as in

More information

Flygt 3057, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification Flygt 3057, 50Hz Technical Specification Table of Contents Table of Contents C-pump...2 Product description...2 Motor rating and performance curves...4 D-pump...6 Product description...6 Motor rating and

More information

Glossary Of Terms M-1

Glossary Of Terms M-1 Glossary Of Terms ANSI - American National Standards Institute. Armor - A sheath, serving, braid or other layer of metal applied over a cable to increase its mechanical protection. ARR - Association of

More information

600 VOLT 600V, 3 CONDUCTOR (WITH GROUND), FR-EPR OR FR-XLPE INSULATION, PVC JACKET SPECIFICATIONS (FLAME RETARDANT POWER CABLE) (UL TYPE TC-ER) TYPE C3 SPEC 70.0100 PROJECT 196116 REFERENCE: LATEST EDITIONS

More information

Flat polyvinyl chloride sheathed flexible cables

Flat polyvinyl chloride sheathed flexible cables BRITISH STANDARD BS EN 50214:2006 Flat polyvinyl chloride sheathed flexible cables The European Standard EN 50214:2006 has the status of a British Standard ICS 29.060.20 BS EN 50214:2006 National foreword

More information

Accessories. l Nickel or nickel-plated copper unipolar, tripolar and tetrapolar cables for high temperatures

Accessories. l Nickel or nickel-plated copper unipolar, tripolar and tetrapolar cables for high temperatures ... Infinite solutions... Accessories l Nickel or nickel-plated copper unipolar, tripolar and tetrapolar cables for high temperatures l Compensation/extension cables for thermocouples and thermoresistances

More information

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE

OSNALINE. Tubes and tube bundles. Member of the KME Group. KME Germany AG & Co. KG [GB] OSNALINE OSNALINE Tubes and tube bundles KME Germany AG & Co. KG OSNALINE [GB] Member of the KME Group KME Germany AG & Co. KG Experts in tube bundles KME Germany AG & Co. KG is a member of the KME Group S.p.A.

More information

Technical Specification for Plastic-Insulated Low Voltage Cables

Technical Specification for Plastic-Insulated Low Voltage Cables Page 1/9 Technical Specification for Plastic-Insulated Low Voltage Cables This technical specification is valid for the business unit E.ON Sweden of the market unit E.ON Nordic With this specification,

More information

Introduction. Railway Cables

Introduction. Railway Cables Railway Cables Introduction Railway Cables Plant Kapfenberg-Einöd Pengg Kabel GmbH is an Austrian cable manufacturer and a member of the german Wilms group with two plants in Styria. We have two sites,

More information

NPS/001/007 Technical Specification for Overhead Line Conductors

NPS/001/007 Technical Specification for Overhead Line Conductors Version:- 7.0 Date of Issue:- September 2016 Page 1 of 27 NPS/001/007 Technical Specification for Overhead Line s 1. Purpose The purpose of this document is to detail the range and technical performance

More information

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Magnetic float switch For vertical installation Model FLS for nuclear power plants Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost

More information

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics HEKAPLAST PE-HD twin wall cable ducts and cable protection pipes for underground installation HEGLER HEKAPLAST III/ HEKAPLAST: Twin wall cable ducts or cable protection pipes to DIN 696, manufactured from

More information

COPPER ALUMINUM PARTS AND SUB-ASSEMBLIES

COPPER ALUMINUM PARTS AND SUB-ASSEMBLIES COPPER Copper Wire Rod... 06 Copper Anodes... 07 Copper Cathode Sheets... 07 Copper Ingots... 07 Single Wires... 08 Welding Wires... 08 Multiwires... 09 Stranded Wires... 10 Litz Cables... 11 Flat Wires,

More information

WHITE PAPER Flex Life vs Flexibility

WHITE PAPER Flex Life vs Flexibility WHITE PAPER Flex Life vs Flexibility The design criteria for both flex life and flexibility is the same but the properties and application of the elements can be vastly different. The design elements are

More information

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 604 NOVEMBER 2017 CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE TABLE OF CONTENTS 604.01 SCOPE 604.02 REFERENCES 604.03 DEFINITIONS - Not Used

More information

M16 M20 M25 M207 M51 M100 M200

M16 M20 M25 M207 M51 M100 M200 Metal Film Fixed Resistor Specifications Per IEC 60115-1 MIL-R-10509 d L H D Features Conformal multi-layer coating Color code per MIL & EIA standards Special tin-plated electrolytic copper lead wire Products

More information

N-pump, Standard Motor

N-pump, Standard Motor N-pump, Standard Motor N-pump, Standard Motor Product description Usage Installation type P, S, T, Z Installation type L A submersible pump for efficient pumping of clean water, surface water, and wastewater

More information

Wire and Cable SPEC 44 Wire and Cable

Wire and Cable SPEC 44 Wire and Cable High-performance wire and cable sulation system for 65 C to Wire and Cable SPEC 44 Wire and Cable Applications Hookup and signal wire and cable used aircraft, avionics, military electronics, satellites,

More information