1 M/s. NILAWAR LABORATORIES, NAGPUR M/s. Nilawar Laboratory, has started functioning in the year 2001 in Nagpur. It has been established with a firm commitment to deliver the best service in terms of most superior quality and high precision results to its most valued clients all over the country. Within a short span of 10 years period it is enlisted as an approved laboratory by our esteemed customers namely i) Indian Oil Corporation Limited ii) Gas Authority of India Limited iii) Government of Maharashtra etc. M/s Nilawar Laboratories is equipped with modern analytical instruments (for physico-chemical, microbiologial and civil parameters) and a team of highly placed, experienced scientist, researchers, lab. technicians and qualified engineers. We always look forward to put more efforts to improve infrastructure so as to meet the ever changing needs of our esteemed clients. M/s. Nilawar Laboratory, is a division of MNEC Consultants Pvt. Ltd. We collectively undertake following services; Testing & Investigation i) Physico-Chemical Analysis of Soil & Water. ii) Microbiological Analysis of Soil & Water iii) Civil Parameters for soil & rocks for construction work. iv) Environment Impact Assessment & EMP v) Geotechnical Invesgitation vi) Soil Resistivity. Partial List of Some of Our Esteemed Client : Sr. No. Name of Client 1. Mah. Govt. Z. P. Buldhana, Jalswarajya Project 2. National Agricultural Innovation Project (NAIP) of Govt. of Maharashtra. (MAFSU & ICAR) 3. Mah. Govt. Irrigation Dept. 4. Public Works Division, Maharashtra. 5. National Highways Page 1 of 5
2 Sr. No. Name of Client 6. Water Supply & Sanitation Committee of various Gram Panchayats in Vidarbha Region. 7. Indian Oil Corporation Limited 8. GAIL (India) Limited 9. Powergrid Corporation of India Limited 10. Oil & Natural Gas Limited 11. ESSAR Oil Limited 12. TATA Projects Ltd. 13. GAMMON India Ltd. 14. Satyam Computer Systems Ltd. 15. Minenviron Systems Pvt. Ltd. 16. Rake Power Ltd. 17. Maharashtra State Mining Corporation 18. Manganese Ore India Limited 19. Shivraj Minerals Pvt. Ltd. 20. MSPL Limited 21. Pavri Kyanite Pvt. Ltd. 22. Naresh Kumar & Company Ltd. 23. ACC Cement Ltd. 24. Indiabulls Power Limited 25. Indiabulls Realtech Limited 26. Indiabulls Infrastructure Limited 27. Adani Mining Pvt. Ltd. 28. Jyoti Structures Limited 29. Reliance Power Transmission Limited. 30. SMS Infrastructure Limited 31. Central Railway 32. South East Central Railway. 33. Maharashtra State Electricity Transmission Co. Ltd. 34. Maharashtra State Power Generation Co. Ltd. * - The detailed list includes numerous public and private sector clients, industrial establishments, Architects, Structural Designers etc. Page 2 of 5
3 PARAMETERS UNDERTAKEN A] Analysis of Pesticides & Organic Components by Gas Chromatograph : i) Gas Chromatograph analysis of Pesticides, Benzene, Benzo (α) Pyrene in water, air and soil. ii) Atomic Absorption Spectrophotometer analysis of metals, traces & toxic metals in water, air and soil. B] Physico-Chemical Analysis of Soil & Water: 1. ph, 2. Colour, 3. Odour, 4. Moisture, 5. Organic Matter 6. Total Dissolved Solids 7. Hardness 8. Salinity 9. Calcium (Ca 2+ ) 10. Chloride (Cl - ) 11. Magnesium (Mg 2+ ) 12. Free Chlorine 13. Sodium (Na + ) 14. Sulphate (SO 2-4 ) 15. Potassium (K + ) 16. Iron 17. Alkalinity 18. Fluoride (F - ), 19. Nitrite (NO - 2 ) 20. Nitrate (NO - 3 ) 21. Phosphate (PO 3-4 ) 22. Oxygen Activity 23. Redox Potential 24. Turbidity 25. Electrical Conductivity (Soil Resistivity). 26. Trace Metals 27. Toxic Metals. C] Microbiological Analysis: 1. Aerobic Bacteria 2. Anaerobic bacteria 3. Coliforms. D] Air Sampling : 1. Suspended Particulate Matter (SPM) 2. Respirable Particulate Matter (RPM) 3. Oxides of Sulphur (SO X ) 4. Oxides of Nitrogen (NO X ) 5. Carbon monoxide (CO) 6. Ozone 7. Ammonia 8. PM PM Lead 11. Nickel 12. Arsenic 13. Benzene & Benzo (α) Pyrene (BaP). E] Analysis of Sewage/Industrial Effluents: 1. Colour 2. Odour 3. Temperature 4. ph 5. Total Solids 6.Suspended Solids 7. Dissolved Solids 8. Settleable solids 9. Nitrite 10. Chemical Oxygen Demand (COD) 11. Nitrate 12.Alkalinity 13. Phosphate (PO 3-4 ) 14. Sulphate Page 3 of 5
4 (SO 2-4 ) 15. Chloride (Cl - ) 16. Oil & Grease 17. Phenols. 18. Biological Oxygen Demand 19. Dissolved Oxygen 20. Iron 21. Zinc 22. Lead 23. Arsenic 24. Mercury. F] Mechanical Tests: 1. Sieve Analysis- Particle Size, 2. Direct Shear Test 3. Hydrometer Analysis 4. Consolidation Test 5. Atterberg s limit: Plastic & Liquid Limit, Plasticity Index 6. Permeability Test 7. Swelling Pressure 8. C.B. Ratio 9. Bulk Density, Field Density 10. Specific Gravity, 11. Optimum Dry Density 12. Shrinkage Limit, 13. Optimum Moisture Content 14. Free swell Index 15. Unconfined Compression Test. 16. Resistivity, 17. Safe Bearing Capacity 18. Void ratio 19. Dry Density, 20. Compression Test, 21. Loss on Ignition, 22. Water soluble compounds. 23. Unconsolidated undrained triaxial compressive strength, 24. Consolidated undrained triaxial compressive strength. 25. Permeability Test 26. Standard proctor / equivalent IS test 27. Modified proctor density test 28. Water Absorption 29. Los Angeles Abrasion Test 30. Impact Value 31. Crushing Value 32. Flakiness Index 33. Elongation Index. 34. Soundness 35. Alkali Reactivity 36. Moisture Content 37. Fineness Modulus & Sieve Analysis. 38. Unit Weight / Density 39. Absorption & Specific Gravity 40. Bulking of Sand 41. Silt Content 42. Soundness 43. MS Bar 6 & 8 mm dia. 44. Tor Steel bar (10mm to 28mm & above) 45. Tensile on Hard drawn wire with reverse bend test on shealthing 46. Hard drawn wire without reverse bend test 47. Strained upto 12 mm breaking load. (above 8mm dia upto 20mm) 48. Flat sections from Structural Steel sections upto 12mm thick Max width 25mm only. 49. Flat sections from Structural steel sections 12 x 25mm width % proof stress (6 to 20mm dia) % proof stress (above 20mm dia) 51. Bend Test MS bar 6 & 8 mm dia. 52. Bend Test Tor steel bar (10mm to 16mm dia) 53. Bend Test Tor steel bar (20mm to 32mm dia) 54. Bend Test Tor steel bar (above 32mm dia) 55. Bend test for structural steel upto 12mm thick x 40 mm width. 56. Bend Test on structural steel upto 25mm 57.Re-Bend Test MS bar 6 & 8mm dia. 58. Re-Bend Test for steel bar (10mm to 16mm dia) 59. Re-Bend Test for steel bar (20mm to 32mm dia) Page 4 of 5
5 G] Cement Testing & Concrete Mix Design: All the parameters for cement and concrete mix design. Recognition & Approvals : M/s. Nilawar Laboratories has received recognition from Indian Oil Corporation Limited, on the panel of Water Supply & Sanitation Department & Agricultural Department, Govt. of Maharashtra. ** Any other parameter as desired by the client. M/s. Nilawar Laboratories, At Km Stone 16.5, Near Hotel Shahenshah, Amravati Road, Waddhamana, Nagpur Page 5 of 5
6
7
8
9
10
11
(DEPARTMENT OF CIVIL ENGINEERING)
CONSULTANCY & MATERIAL TESTING SERVICES (DEPARTMENT OF CIVIL ENGINEERING) VNR VIGNANA JYOTHI INSTITUTE OF ENGINEERING & TECHNOLOGY Bachupally, Nizampet( S.O.),Hyderabad -500 090 Phone: 040-23042758/59/60
More informationNational Accreditation Board for Testing and Calibration Laboratories. (A Constituent Board of Quality Council of India) CERTIFICATE OF ACCREDITATION
(? (A Constituent Board of uality Council of India) C I CERTIFICATE OF ACCREDITATION M.E. TESTING LABORATORY has been assessed and accredited in accordance with the standard ISO/IEC 17025:2005 "General
More informationDepartment of Civil Engineering. Consultancy Experiments and Charges
Department of Civil Engineering Consultancy Experiments and Charges TRANSPORTATION ENGINEERING LABORATORY Rate Per Test (Rs.) S.N0. Test Name Proposed = Existing existing *1.5 1 CBR @ Field moisture Contents
More informationSuperintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal
Last Amended on - Page 1 of 16 I. WATER 1. Drinking Water ph IS 3025 (Part 2): 2004, Colour APHA (22 nd Edition) 2120 B: Turbidity (NTU) IS 3025 (Part 10): 1984 Residual, Free Chlorine IS 3025 Part 26/1986
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9
Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 %
More informationStandard Testing & Engineering, LLC
Standard Testing & Engineering, LLC dba Standard Testing & Engineering Company in Oklahoma City, Oklahoma, USA has demonstrated proficiency for the testing of construction materials and has conformed to
More informationGeotech Services, X-18, MIDC, Hingna, Nagpur, Maharashtra. Discipline Mechanical Testing Issue Date
Last Amended on 11.01.2014 Page 1 of 14 I. BUILDING MATERIALS 1. Soil / Rock Plate Load Test IS 1888 1982 (Reaffirmed-2007) Cyclic Plate Load Test IS 5249 1992 Clause 6 (Reaffirmed-2010) Load Test On In-Situ
More informationDiscipline Mechanical Testing Issue Date Certificate Number T-2522 Valid Until Last Amended on - Page 1 of 13
Bureau Veritas (India) Pvt. Ltd. - Construction Services, Last Amended on - Page 1 of 13 I. MECHANICAL PROPERTIES OF MATERIALS 1. Steel Reinforcement Weight/meter IS 1786: 2008 (RA 2013) 0.1 kg to 20 kg
More informationANNEXURE- II Proposed TOR
ANNEXURE- II Proposed TOR Annexure II Terms of Reference for EIA for Setting up of Ligno-Cellulosic Biomass based second generation (2G) Ethanol Bio-Refinery with capacity of 100 KLPD at village-sainjani,
More informationBhumi Research Centre (Civil Engineering Testing Laboratory), 2/1362, 'Bhumi House', Sagrampura, Ring Road, Surat, Gujarat
Bhumi Research Centre (Civil Engineering Testing ), Last Amended on - Page 1 of 6 AT LABORATORY I. SOIL & ROCK 1. Soil Grain Size Analysis IS 2720 (Part 4): 1985 Rev. 2, (RA 2007) Hydrometer Analysis IS
More informationBeyond Engineering & Testing, LLC.
in Round Rock, Texas, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation policies established
More informationGeoTesting Express, Inc.
in Acton, Massachusetts, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation policies
More informationPrakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat
Prakruti Environmental Engineers (Environmental ), Last Amended on - Page 1 of 7 I. WATER 1. Water (Ground Water/ Surface Water/ Drinking Water/ Treated Water) ph APHA 4500-H + B, Temperature APHA 2550
More informationLIST OF DAC (17025) ACCREDITED TESTS CONSTRUCTION MATERIALS TESTING. Determination of sulphate content of soil and ground water testing
LIST OF DAC (17025) ACCREDITED TESTS CONSTRUCTION MATERIALS TESTING WATER: Material / Product Description Chemical Water Determination of ph Value 02 Chemical Water Determination of sulphate content of
More informationRaicon Labs Pvt. Ltd., Plot No. 140, HSIIDC, Rai Industrial Area, Sonepat, Haryana. Discipline Mechanical Testing Issue Date
Last Amended on - Page 1 of 9 I. BUILDING MATERIALS 1. Cement Fineness by Blain Air Permeability IS 4031 (Part 2): 1999 (RA 2013) 100 m 2/ kg to 500 m 2/ kg Consistency IS 4031 (Part 4): 1988 (RA 2014)
More informationNexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka
Certificate Number TC-5069 (in lieu of T-3362 & T-3363) Page 1 of 17 Range ing / BIOLOGICAL TESTING I. WATER 1. Drinking Water R.O. Water, Ground Water, Surface Water, Treated Water. 2. Waste Water/ Effluents
More informationKKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana
Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m
More informationRECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed
Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part
More informationLaboratory Certification For. Build Afghanistan Engineering Services (BAES) Laboratory
Laboratory Certification For Build Afghanistan Engineering Services (BAES) Laboratory Lab ID: LCP-017 Issue date: Oct 5, 2016 Expiry date: April 4, 2017 This Extension letter confirms the completion of
More informationStandard test method for organic impurities in fine aggregates for concrete. Standard test method for chemical analysis of hydraulic cement
IAS Accreditation Number TL-454 Company Name (QEL)- Foreign Branch Address Shed-9, Building-2189, Road-1529, Block 115 P.O. Box 50191 Hidd Kingdom of Bahrain Contact Name Sreekala Prabasankar, Technical
More informationENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka
Certificate Number TC-6325 Page 1 of 5 Range ing / CHEMICAL TESTING I. WATER 1. Surface Water, Ground Water, Industrial Water, Drinking Water, Irrigation Water, Water From Purifiers & Swimming Pool Water
More informationNichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka
Last Amended on - Page 1 of 9 I. WATER 1. Drinking Water Colour 2120 B 1 to 100 Hazen Units ph 4500 H+, B 3 to 12 Electrical conductivity 2510 B 5 to 10,000 µs/cm Turbidity 2130 B 1 to 100 NTU Chloride
More informationDeep Testing Laboratories, Plot No.- 338, Sector-58, Ballabhgarh, Faridabad, Haryana. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 6 I. METALS & ALLOYS 1. Plain Carbon & Low Alloy Steels Carbon IS 228 (Part-1) 1987, RA 2007 0.05% to 2.5% Mn IS 228 (Part-2) 1987, RA 2002 0.1% to 2.5% Si IS 228 (Part-8) 1989,
More informationEnvironment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand
Environment, Central Mine Planning and Design Institute Last Amended on - Page 1 of 9 1. POLLUTION & EFFLUENTS 1. Effluent / Waste Water Ammonical Nitrogen Free Ammonia IS 3025 (Part 34):1988, Nessler
More informationAnnex 7.1 National Ambient Air Quality Standards for Nepal, 2003
Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003 Parameters Units Averaging Time TSP (Total Suspended Particulars) Concentration in Ambient Air, maximum Test method µg/m 3 Annual - 24-hours*
More informationFollowing are key codes & standards to remember for Civil Estimators to prepare the tender/bid proposal in correct manner.
CODES & STANDARDS FOR ON-SITE TESTING LABORATORY Following are key codes & standards to remember for Civil Estimators to prepare the tender/bid proposal in correct manner. Codes & Standards are published
More informationWinmet Technologies Private Limited, Plot No. E-65, Site-IV, UPSIDC, Greater Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 8 I. AIR, GASES & ATMOSPHERE 1. Ambient Air PM 2.5 PM10 (RSPM) WMN/ENV/AIR/03, Issue no. 1 dated 01.10.2013 IS: 5182 (Part -23)-2006, 10 500 µg/m 3 10 1000 µg/m 3 Suspended
More informationHaryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date
Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide
More informationAppendix U. Mapping of Water Quality Concentration Contours across the Province
ALDERON IRON ORE CORP. ENVIRONMENTAL IMPACT STATEMENT KAMI IRON ORE MINE AND RAIL INFRASTRUCTURE, LABRADOR Appendix U Mapping of Water Quality Concentration Contours across the Province Figure 17I.1 Alkalinity
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on
Last Amended on 18.01.2016 Page 1 of 8 I. WATER 1. Potable, Domestic and Bore-well Water ph IS 3025 (Part 11): 1983 Electrometric Method Colour IS 3025 (Part 4): 1983 Specific Conductance IS 3025 (Part
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5
Last Amended on - Page 1 of 5 AT LABORATORY I. WATER 1. Drinking Water, Colour IS 3025 (Part 4): 1983 (RA 2002) Spectrometer method 2120C Odour IS 3025 (Part 5): 1983 (RA 2002) 2 Hazen units to 500 Hazen
More informationPennoni Associates, Inc.
in Bethlehem, Pennsylvania, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation policies
More informationMECON LIMITED RANCHI , INDIA
ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF JULY 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 SEPTEMBER, 2011
More informationEPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)
NORTH TEXAS MUNICIPAL WATER DISTRICT - Wylie Water Analysis Jan-2018 Mineral Analysis Raw Treated Standards Residue on Evaporation 412 456 500 1000 Silica (SiO2) 3.63 3.41 Iron (Fe) 0.378 0.259 0.3 0.3
More informationGeotechnics, Inc. East Pittsburgh, Pennsylvania, USA
in East Pittsburgh, Pennsylvania, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation
More informationCHAPTER-3 PROGRAMME 121
120 CHAPTER-3 TESTS ON MATERIALS USED IN THE EXPERIMENTAL PROGRAMME 121 3.1 General 121 3.2 Cement 121 3.3 Fine Aggregate 122 3.3.1 Specific Gravity of Fine Aggregate 123 3.3.2 Bulk Density of Fine Aggregate
More informationFlood Testing Laboratories, Inc.
in Chicago, Illinois, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation policies established
More informationCapability Statement
Capability Statement Trilab is Australasia's leading independent supplier of specialised soil and rock mechanics testing, to the Asia-Pacific mining, civil construction and infrastructure industries. Two
More informationMahabal Enviro Engineers Pvt. Ltd. Pollution monitoring, Engineers & Contractors in Environmental Management
PROPOSED RESIDENTIAL CUM COMMERCIAL PROJECT WITH MCGM PARKING LOT, AT LOWER PAREL, MUMBAI, MAHARASHTRA GROUND WATER ANALYSIS October, 2017 Parameter Units Sample 1 Source Location Date of collection of
More informationMECON LIMITED RANCHI , INDIA
ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF SEPTEMBER 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 OCTOBER, 2011
More informationTerracon Consultants, Inc.
in College Station, Texas, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation policies
More informationGOVERNMENT ENGINEERING COLLEGE BANSWARA
GOVERNMENT ENGINEERING COLLEGE BANSWARA CIVIL ENGINEERING DEPARTMENT Date: Third year students of Civil Engineering, B.Tech has visited BVM Vallabh Vidyanagar from 27/04/2018 to 02/05/2018. During the
More informationOklahoma DOT Central Laboratory Test List
Aggregate Count of Tests: 21 Aggregate Durability Index 00091 T210 AR Bulk Density and Voids 00086 T19 AR Clay Lumps and Friable Particles 00080 T112 AR OHDL9-OHDL38 Dust Coating of Cover Aggregates 00149
More informationQUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;
REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : ENVIRONMENTAL DATA - Temperature min. : C - Temperature max. : C - Altitude (m.a.s.l) : m - Plant location (geographic area, seismic zone,
More informationGeotechnics, Inc. East Pittsburgh, Pennsylvania, USA
in East Pittsburgh, Pennsylvania, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation
More informationSCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS
SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,
More informationSWANA 2017 Leachate Basics and Quality Changes with Organics Removal. Steve Johnson M.Eng., P.Eng.
SWANA 2017 Leachate Basics and Quality Changes with Organics Removal Steve Johnson M.Eng., P.Eng. May 2017 2 Landfills that take over 10,000 tonnes per year? How many of you have leachate collection systems?
More informationMadhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh
Madhya Pradesh Waste Management Project, Certificate Number TC-5022 (in lieu of T-2449) Page 1 of 8 CHEMICAL TESTING I. POLLUTION AND ENVIRONMENT 1. Waste Water (Effluent & Sewage) ph APHA 22nd Edition,
More informationA. Water sampling and analysis
A. Water sampling and analysis Parameter monitored Standard methodology used Detection limit Is this company accredited for this test? 1 ph Potentiometer 0.01 ph units No Temperature Electrometer probe
More informationAbuja, May 2008
Waste Water Treatment and Water Quality Based on UNSD Questionnaire 2002 and 2004 United Nations Statistics Division Workshop on Environment Statistics Abuja, 19-23 May 2008 Waste water generation Total
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK shghal Centre for Research and Development ccredited to l Najma Street number
More informationEffect of Curing on Soil Stabilized with Egg Shell
IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): 2349-784X Effect of Curing on Soil Stabilized with Egg Shell Karthika Prasad Prabhu P James
More informationLABORATORY TURNAROUND TIMES AND CHARGES
LABORATORY TURNAROUND TIMES AND CHARGES The enclosed prices reflect a 5 business day turnaround time. There will be a $25.00 minimum charge per report. Same Day Rush 24 Hour Rush 48 Hour Rush 72 Hour Rush
More informationPanasonic India Pvt. Ltd.
Panasonic India Pvt. Ltd. December-2014 FOR Industrial Building of Panasonic India Ltd At Jhajjar, Haryana 1 Details of Environmental Monitoring INTRODUCTION M/s Panasonic India Pvt Ltd granted its Environmental
More informationEffect of Stone Slurry And Crumb Rubber on Phosphogypsum Treated Clay
Effect of Stone Slurry And Crumb Rubber on Phosphogypsum Treated Clay Jildha Janardhanan 1, Nithin Joseph 2, Pournami R 3, Unnikrishnan M 4, Vidya V 5, Sankar Bose 6 1, 2, 3, 4, 5 B-Tech Students, Civil
More informationSTRATA Certified Laboratory Tests
STRATA Certified Laboratory Tests Table 1. List of Certified Soil Tests 1 ASTM D 422 Standard Test Method for Particle-Size Analysis of Soils 2 ASTM D 698-12 Standard Test Method for Compaction Characteristics
More informationCERTIFICATE OF ANALYSIS
1 CERTIFICATE OF ANALYSIS ATTENTION: Water Purification Solutions DATE: 29 November 2018 1. GENERAL: Table-1: Tierkloof Borehole & Product - Sampled 1 November 2018 Results expressed in parts per million
More information2019 Microbac Laboratories Inc. Ohio Valley Division
STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES LABORATORY CERTIFICATION BRANCH In accordance with the provisions of N.C.G.S. 143-215.3 (a) (1), 143-215.3 (a)(10)
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NORTHWEST GEOTECH, INC. d/b/a NORTHWEST TESTING, INC. 9120 SW Pioneer Court, Suite B Wilsonville, OR 97070 Thomas Ginsbach, P.E. Phone: 503 682 1880 Valid To:
More informationLABORATORY INSPECTION INFORMATION REQUEST
LABORATORY INSPECTION INFORMATION REQUEST This information will assist in the processing of laboratory inspections. The inspection is a two-man day comprehensive review that includes review of the quality
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
This annex is valid from: 16-08-2017 to 01-08-2020 Replaces annex dated: 23-05-2016 Vlamoven 41 6826 TM Arnhem The Netherlands Location(s) where activities are performed under accreditation Head Office
More informationFHWA-Western Federal Lands Highway Division
in Vancouver, Washington, USA has demonstrated proficiency for the testing of construction materials and has conformed to the requirements established in AASHTO R 18 and the AASHTO Accreditation policies
More informationLaboratory Turnaround Times and Prices
4619 N. Santa Fe Ave. Oklahoma City, OK 73118 (405) 488-2400 Laboratory Turnaround Times and Prices The enclosed prices reflect a five (5) business day turnaround. There will be a minimum charge of $25.00
More informationCivil Engg. Department Semester : 5
Civil Engg. Department Semester : 5 Teaching Scheme Course Code Course Name Lecture hours Tutorial hours Practical hours Credit CE 3001 Matrix Analysis of Structures 1 1 0 2 CE 3002 Soil Mechanics 3 1
More informationState of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation
Matrix: CWA (Non Potable Water) Discipline: Chemistry ASTM D516-07 ASTM D6888-09 ASTM D7511-09e2 EPA 160.4 EPA 1631E EPA 1664A EPA 1664A (SGT-HEM) EPA 180.1 Sulfate 8/1/2018 Cyanide, Amenable 8/1/2018
More informationEnvironment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra
Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D
More informationCelebrating Silver Jubilee Year ( ) Celebrating Silver Jubilee Y
Celebrating Silver Jubilee Year (2010-2011) Celebrating Silver Jubilee Y Page 1 of 9 NABL ACCREDITED LAB AS PER ISO / IEC 17025:2005 CSRL - STRUCTWEL LAB (Pune) Pvt. Ltd. 54, Progress House, Pune - Mumbai
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 3573 Laboratory Name: AGAT Laboratories (Grande Prairie) Parent Institution: AGAT Laboratories Ltd. Address: 10203B - 123 Street Grande Prairie AB T8V
More informationCALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing
CALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing Basic Laboratory, Inc. 2218 Railroad Avenue Redding, CA 96001 Phone: (530) 243-7234 Field of Testing: 101 -
More informationParameter monitored Standard methodology used Detection limit
A. Water sampling and analysis ph Potentiometry 0.0 ph units No Temperature Electrometer probe (in-situ) 0.05 o C No Dissolved oxygen Electrometer probe (in-situ) % No Salinity Electrometer probe (in-situ)
More informationDiscipline Mechanical Testing Issue Date Certificate Number T-1169 Valid Until Last Amended on
Last Amended on 08.06.2015 Page 1 of 8 I. MECHANICAL PROPERTIES OF MATERIALS 1. Reinforcing Bar Nominal mass of HSD rebar IS 1786: 2008 (RA 2013) 0.075 kg/m to 15 kg/m Tensile Test of HSD rebar 2. Strands
More informationChecklist for Ready Mix Concrete Supply of Concrete (RMC)
C.A.01/CIDCO/SE(KHR)/EE(KHR-I)/2010 11 Pg. 568 Checklist for Ready Mix Concrete Supply of Concrete (RMC) Name of Work : C.A. : Name of Contractor/Client : 1. Name of RMC manufacturer with plant address
More informationWest Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division
West Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division to perform analyses for the purpose of determining compliance with the requirements of the state's
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),
More informationManufactured Sand, A Solution And An Alternative To River Sand And In Concrete Manufacturing
Manufactured Sand, A Solution And An Alternative To River Sand And In Concrete Manufacturing Dr.S.Elavenil, Professor in Civil Engg,S.R.M.University, Kattankulathur, India B. Vijaya, Assistant Professor
More informationSubmitted by: M/s Panasonic India Ltd
Environmental Monitoring Report (June-2014) FOR Industrial Building of Panasonic India Ltd At Jhajjar, Haryana Submitted by: M/s Panasonic India Ltd INDUSTRIAL PLOT NO-1, VILLAGE- BID DADRI JHAJJAR (HARYANA)
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Annex to declaration accreditation (scope accreditation) Location(s) where activities are performed under accreditation Head Office Vlamoven 41 6826 TM Arnhem The Netherlands Location Abbreviation/ location
More informationAssessment of Water Quality of Three Different Aquatic Environments Over Three Seasons
2014 1 st International Congress on Environmental, Biotechnology, and Chemistry Engineering IPCBEE vol.64 (2014) (2014) IACSIT Press, Singapore DOI: 10.7763/IPCBEE. 2014. V64. 10 Assessment of Water Quality
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 2635 Laboratory Name: Taiga Environmental Laboratory Parent Institution: Government of Northwest Territories (GNWT) Address: P.O. Box 1320 4601-52nd Avenue
More informationInternational Journal of Advance Engineering and Research Development
Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 4, Issue 11, November -17 e-issn (O): 2348-4470 p-issn (P): 2348-66 AN EXPERIMENTAL
More informationFrench Creek Well # 2 Water Analysis Behind 1221 Ormonde Road
French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road October 27 2010 Inorganics Fluoride 1.5 MAC 0.17 0.13
More informationAccredited Laboratory
Accredited Laboratory A2LA has accredited Houston, TX for technical competence in the field of Construction Materials Testing This laboratory is accredited in accordance with the recognized International
More informationCALA Directory of Laboratories
CALA Directory of Laboratories Membership Number: 4114 Laboratory Name: African Assay Laboratories Ltd (Tanzania)- Environmental Laboratory Parent Institution: Address: Balewa Road Mwanza 255 Contact:
More informationPoint wise compliance for the conditions stipulated in Environmental Clearance of (Phase- I & II)
SIX MONTHLY ENVIRONMENTAL COMPLIANCE STATUS REPORT (PERIOD : OCT, 2017 to MARCH, 2018) Ref: J-13011/23/2007-IA-II (T) Dated: 17/07/2007 (as amended in the Year, 2013 & 2014) and J-13011/46/2007-IA-II (T)
More informationDetroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 10/14/2014
Lake Huron Plant Turbidity NTU 0.43 0.04 0.3/95% (1) Total Solids mg/l 103 116 500 10 Total Dissolved Solids mg/l 112 142 500 10 Aluminum Al mg/l < 0.050 < 0.050 0.05-0.2 0.005 Iron Fe mg/l 0.053 < 0.050
More informationANALYTES available for testing
ANALYTES available for testing codes WS = water supply, drinking water, potable water WP = wastewater, general water quality, ODA OK = Oklahoma DEQ ODA = Oklahoma Department of Agriculture KS = Kansas
More informationCE 370. Wastewater Characteristics. Quality. Wastewater Quality. The degree of treatment depends on: Impurities come from:
CE 37 Wastewater Characteristics Quality Wastewater Quality The degree of treatment depends on: Influent characteristics Effluent characteristics Impurities come from: Domestic activities Industrial activities
More informationAppendix I. Agreement on National Environmental Standards of Lao PDR, 2009
Appendix I Agreement on National Environmental Standards of Lao PDR, 2009 I.1 DRINKING WATER QUALITY STANDARDS Lao PDR current standards for drinking water of the Lao PDR are provided below for reference.
More informationAccredited Laboratory
Accredited Laboratory A2LA has accredited (FORMERLY KNOWN AS GORRONDONA & ASSOCIATES, INC.) Houston, TX for technical competence in the field of Geotechnical Testing This laboratory is accredited in accordance
More informationMahabal Enviro Engineers Pvt. Ltd. At Booty, Near PHED Colony, Behind Pump House, PO - RMCC, District - Ranchi
Eco 'Ventures Pvt. Ltd Regd. Office: 2/37, Sarvapriya Vihar, Near IIT Gate, New Delhi-110016 Corporate Office: 7/8 Bhaveshwar Bhuvan, Opp Porthugese Church, Near Dindayal Upadhyay Garden, Gokhale Road
More informationSpecial Provision No. 199S64 July 2016
GENERAL REQUIREMENTS FOR REFEREE TESTING Special Provision No. 199S64 July 2016 1.0 Scope This Special Provision describes the common requirements for referee testing related to laboratory and field testing
More informationFinal Report DMR-QA 36. NPDES Permit: IL DMR-QA Study. Open Date: 03/18/16. Close Date: 07/01/16. Report Issued Date: 07/29/16
Keith Richard Decatur Sanitary District Decatur, IL 62522-1842 USA DMR-QA 36 Final Report NPDES Permit: IL0028321 DMR-QA Study Open Date: 03/18/16 Close Date: 07/01/16 Report Issued Date: 07/29/16 Study
More informationDurban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014
Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July 2013-30 June 2014 Durban Heights WW Raw Durban Heights WW Final Determinands Units Minimum Average Percentile Maximum Minimum Average
More informationFinal Report WP-225. WatR Pollution Study. Open Date: 10/18/13. Close Date: 12/02/13. Report Issued Date: 12/04/13
WP-225 Final Report WatR Pollution Open : 10/18/13 Close : 12/02/13 Report Issued : December 4, 2013 Enclosed is your final report for ERA's WP-225 WatR Pollution Proficiency Testing (PT) study. Your final
More informationREVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS)
REVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS) Background PEPC in its first meeting held on 10 th May 1993 approved the NEQS. The approved NEQS were uniform standards applicable to all kind of
More informationEFFECT OF CHROME TANNING EFFLUENT ON COHESIVE SOILS
EFFECT OF CHROME TANNING EFFLUENT ON COHESIVE SOILS S. Sathish 1, K. Thamaraiselvan 2, P.A. Theenesh 3, C. Venkatesh 4, T.R. Banu Chander 5 1,2,3,4UG Student, Department of Civil Engineering, Valliammai
More informationAN EXPERIMENTAL STUDY ON PARTIAL REPLACEMENT OF CEMENT WITH EGGSHELLS POWDER AND AGGREGATES WITH COCONUT SHELLS
AN EXPERIMENTAL STUDY ON PARTIAL REPLACEMENT OF CEMENT WITH EGGSHELLS POWDER AND AGGREGATES WITH COCONUT SHELLS v.haripriya 1, k.bulliraju 2, k.bhuvaneswari 3, p.v.ragavendra 4 and k.anil Chowdary 5 1,2,3,4
More information