1 2015 CATALOG WIRE and borderstates.com

2 Table of CONTENTS Building wire... 3 THHN... 5 THW TFFN... 9 THHN CoilPAK THHN PullPro...13 XHHW NM...18 USE-2/RHW/RHW SER...23 SEU...24 MC Tracer PV Cable...33 Bare Tray cable Instrumentation Control Power limited tray cable Power control cable Power control VFD cable...58 Medium voltage MV MV Lead wire SIS Hook-Up MTW Armored cable AIA AIA CAT 5E MC-HL MC-HL MOD BUS LV Airguard Class 1 Div LV Airguard Class 1 Div MC-HL Medium Volt Teck Industrial cord Type G Industrial cord cont Type GGC Type W Type P DLO Welding SOOW SEOOW SJOOW SJEOOW SJEW SJTO Submersible pump Security CM CMR CMP T-stat Fire alarm and signal Belden VFD Thermocouple Hook-up Classic multi-conductor Classic paired conductor Classic portable cordage Classic industrial cable Utility Overhead secondary Underground secondary Underground primary Bare overhead Galvanized steel strand & static Aluminum tie Riser Belden Index Glossary and Abbreviations Cross References Wire AND SAVE TIME, SAVE MONEY When you re working in the field, you need to save time and money, and you need to stay safe. Our wire services will meet your job site needs, and include color feeder wire; wire paralleling and cutting, on-site delivery, compartmentalized reels, installed pulling heads and specialized reels. We have multiple locations across the U.S. that stock a full selection of colored wire and specialty cables to get you the products you need, when you need them. We can customize your order so your wire is ready to go when we deliver directly to your job site. This catalog highlights the most commonly sold wire and cable. WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH Images courtesy of Belden, Draka, Encore, General Cable, National Strand and Southwire. 2 BORDER STATES

3 Building WIRE In this section THHN... 5 THW TFFN... 9 THHN CoilPAK THHN PullPro XHHW NM USE-2/RHW/RHW SER SEU MC Tracer PV Cable Bare WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

4

5 THHN thermoplastic high heat-resistant nylon-coated Solid Copper 500' AND 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. May be used in dry and damp locations at temperatures not to exceed 90 C, or in wet locations at temperatures not to exceed 75 C. Rated for 600 V The insulation is thermoplastic, flame-retardant and heat resistant with a nylon jacket or equivalent outer covering Maximum operating temperature of 90 C Slick nylon outer jacket for easy pulling Copper based Custom colors UL 83 and 2256 Federal Specification A-A NEMA WC-70 Construction Requirements ASTM - B3, B8 (7,19, 37, 61 strands), B 787 (19 wire combination unilay strands) NEC, NFPA ' REEL Gauge Black Blue Brown Green Gray Orange Pink Purple Red Tan White Yellow ' REEL Gauge Black Blue Brown Green Gray Orange Pink Purple Red Tan White Yellow BUILDING WIRE WIRE AND 5

6 THHN thermoplastic high heat-resistant nylon-coated Stranded 500', 1000' AND 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. May be used in dry and damp locations at temperatures not to exceed 90 C, or in wet locations at temperatures not to exceed 75 C. Rated for 600 V The insulation is thermoplastic, flame-retardant and heat resistant with a nylon jacket or equivalent outer covering Maximum operating temperature of 90 C Slick nylon outer jacket for easy pulling Copper based Custom colors UL 83 and 2256 Federal Specification A-A NEMA WC-70 Construction Requirements ASTM - B3, B8 (7,19, 37, 61 strands), B 787 (19 wire combination unilay strands) NEC, NFPA 70 BUILDING WIRE 500' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Grey Pink Purple Tan / / / / BORDER STATES

7 THHN thermoplastic high heat-resistant nylon-coated Stranded (continued) 500', 1000' AND 2500' REELS Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Gray Pink Purple Tan / / / / ' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Grey Pink Purple Tan / / / / BUILDING WIRE WIRE AND 7

8 THW-2 thermoplastic insulation, heat resistant, suitable for wet locations Stranded 500', 1000' AND 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. May be used in dry and damp locations at temperatures not to exceed 90 C, or in wet locations at temperatures not to exceed 75 C. Rated for 600 V Has thermoplastic insulation that is flameretardant, moisture and heat resistant Maximum operating temperature of 90 C Slick nylon outer jacket for easy pulling Copper based Custom colors Federal Specification A-A NEMA WC-70 Construction Requirements ASTM - B3, B8 (7,19, 37, 61 strands), B 787 (19 wire combination unilay strands) NEC, NFPA 70 RoHS/REACH Compliant 500' REEL Gauge # of Strands Black Green Red White Blue Brown Orange Yellow Gray Pink Purple Tan Gauge # of Strands Black Green Red White Blue Brown Orange Yellow Gray Pink Purple Tan BUILDING WIRE 2500' REEL Gauge # of Strands Black Green Red White Blue Brown Orange Yellow Gray Pink Purple Tan BORDER STATES

9 TFFN thermoplastic insulation, fixture wire, nylon jacket Solid Copper 500' AND 2500' REELS Used as fixture wire, machine tool wiring, or appliance wiring material as specified in the National Electrical Code. Rated for 600 V Has an outer jacket of nylon, or equivalent material Available in AWG sizes #16 or #18 Maximum operating temperature of 90 C Slick nylon outer jacket for easy pulling Copper based Custom colors UL 66 and 758 ASTM - All Applicable Standards NFPA 79 as Appliance Wiring Material NEC, NFPA 70 RoHS/REACH Compliant 500' REEL Gauge Black White Green Blue Red Brown Orange Yellow Pink Purple Gray Tan ' REEL Gauge Black White Green Blue Red Brown Orange Yellow Pink Purple Gray Tan BUILDING WIRE WIRE AND 9

10 TFFN thermoplastic insulation, fixture wire, nylon jacket Stranded Copper 500' AND 2500' REELS Used as fixture wire, machine tool wiring, or appliance wiring material as specified in the National Electrical Code. Rated for 600 V Has an outer jacket of nylon, or equivalent material Available in AWG sizes #16 or #18 Maximum operating temperature of 90 C Slick nylon outer jacket for easy pulling Copper based Custom colors UL 66 and 758 ASTM - All Applicable Standards NFPA 79 as Appliance Wiring Material NEC, NFPA 70 RoHS/REACH Compliant 500' REEL Gauge # of Strands Black White Green Blue Red Brown Orange Yellow Pink Purple Gray Tan ' REEL Gauge # of Strands Black White Green Blue Red Brown Orange Yellow Pink Purple Gray Tan BUILDING WIRE 10 BORDER STATES

11 THHN COILPAK thermoplastic insulation, fixture wire, nylon jacket Solid 600' 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. For use in dry and damp locations. Ergonomically designed and weighs less than 50 lbs., making it easier and safer to transport throughout the jobsite. The unique nesting design makes it easy to stack several high on the floor, either for storage or pulling. Easy stackable construction eliminates the need for setup, just drop and pull. Rated for 600 V The insulation is thermoplastic, flame-retardant and heat resistant with a nylon jacket or equivalent outer covering Maximum operating temperature of 90 C The unique design means you re pulling the weight of the wire, not the entire weight of the spool As part of the SIMpull Circuit Management System, the SIMpull CoilPAK payoff can also work as a seamless complement to the SIMpull WireBARREL wire drum, to help maximize safety, flexibility, efficiency and profitability Copper based Custom colors UL 83 and 2256 Federal Specification A-A NEMA WC-70 Construction Requirements ASTM - B3, B8 (7,19, 37, 61 strands), B 787 (19 wire combination unilay strands) NEC, NFPA 70 Gauge Put-Up Black Blue Brown Green Gray Orange Purple Red White Yellow Green/ Yellow Gray/ Brown ' Reel ' Reel ' Reel ' Reel Gray/ Gray/ Gray/ White/ White/ White/ Black/ Brown/Gray/ Blue/White/ Orange/ Red/White/ Yellow/Gray/ Gauge Put-Up Orange Purple Yellow Black Blue Red White/Green Green Green Gray/Green Green Green ' Reel ' Reel ' Reel ' Reel BUILDING WIRE WIRE AND 11

12 THHN COILPAK thermoplastic insulation, fixture wire, nylon jacket Stranded 600' 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. For use in dry and damp locations. Ergonomically designed and weighs less than 50 lbs., making it easier and safer to transport throughout the jobsite. The unique nesting design makes it easy to stack several high on the floor, either for storage or pulling. Easy stackable construction eliminates the need for setup, just drop and pull. Rated for 600 V The insulation is thermoplastic, flame-retardant and heat resistant with a nylon jacket or equivalent outer covering Maximum operating temperature of 90 C The unique design means you re pulling the weight of the wire, not the entire weight of the spool As part of the SIMpull Circuit Management System, the SIMpull CoilPAK payoff can also work as a seamless complement to the SIMpull WireBARREL wire drum, to help maximize safety, flexibility, efficiency and profitability Copper based Custom colors UL 83 and 2256 Federal Specification A-A NEMA WC-70 Construction Requirements ASTM - B3, B8 (7,19, 37, 61 strands), B 787 (19 wire combination unilay strands) NEC, NFPA 70 Gauge Put-Up # of Strands Black Blue Brown Green Gray Orange Purple Red White Yellow Green/ Yellow Gray/ Brown ' Reel ' Reel ' Reel ' Reel BUILDING WIRE Gray/ Gray/ Gray/ White/ White/ White/ Black/ Brown/ Blue/White/ Orange/ Red/White/ Yellow/ Gauge Put-Up # of Strands Orange Purple Yellow Black Blue Red White/Green Gray/Green Green Gray/Green Green Gray/Green ' Reel ' Reel ' Reel ' Reel BORDER STATES

13 THHN PULLPRO thermoplastic insulation, fixture wire, nylon jacket Solid 1000' 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. For use in dry and damp locations. Unique coil pattern allows for a tangle-free and memory-free pull. PullPro never loses its balance and retains weight distribution during the pull with its state-of-the-art coiling pattern. Rated for 600 V The insulation is thermoplastic, flame-retardant and heat resistant with a nylon jacket or equivalent outer covering Maximum operating temperature of 90 C Package sits upright which makes it easier to lift All PullPro circuit wire comes in lube-free SuperSlick Elite Centered handle allows for even weight distribution Secure it with the pocket when not in use Reduced memory in wire after pulling Can be pulled horizontally or vertically Copper based Custom colors UL 83 and 2256 Federal Specification A-A NEMA WC-70 Construction Requirements ASTM - B3, B8 (7,19, 37, 61 strands), B 787 (19 wire combination unilay strands) NEC, NFPA 70 Gauge Put-Up Black White Red Blue Green Yellow Orange Brown Gray White/ Black White/ Red White/ Blue ' Reel ' Reel ' Reel BUILDING WIRE WIRE AND 13

14 THHN PULLPRO thermoplastic insulation, fixture wire, nylon jacket Stranded 1000' 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. For use in dry and damp locations. Unique coil pattern allows for a tangle-free and memory-free pull. PullPro never loses its balance and retains weight distribution during the pull with its state-of-the-art coiling pattern. Rated for 600 V The insulation is thermoplastic, flame-retardant and heat resistant with a nylon jacket or equivalent outer covering Maximum operating temperature of 90 C Package sits upright which makes it easier to lift All PullPro circuit wire comes in lube-free SuperSlick Elite Centered handle allows for even weight distribution Secure it with the pocket when not in use Reduced memory in wire after pulling Can be pulled horizontally or vertically Copper based Custom colors UL 83 and 2256 Federal Specification A-A NEMA WC-70 Construction Requirements ASTM - B3, B8 (7,19, 37, 61 strands), B 787 (19 wire combination unilay strands) NEC, NFPA 70 Gauge Put-Up # of Strands Black White Red Blue Green Yellow Orange Brown Gray White/ Black White/ Red White/ Blue ' Reel ' Reel ' Reel BUILDING WIRE 14 BORDER STATES

15 XHHW cross-linked, high heat, water resistant insulated Stranded 500' AND 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. May be used in dry and damp locations at temperatures not to exceed 90 C, or in wet locations at temperatures not to exceed 75 C. Rated for 600 V The insulation is flame-retardant, moisture-resistant thermoset Available in sizes from 14 AWG 2000 kcmil Slick nylon outer jacket for easy pulling Copper based Custom colors UL44 / VW1 Federal Specification A-A ASTM - B3, B8 B787 NEMA WC 70/ICEA S NOM-ANCE 90 C NEC, NFPA Edition RoHS/REACH Compliant 500' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Gray Pink Purple ' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Grey Pink Purple BUILDING WIRE WIRE AND 15

16 XHHW cross-linked, high heat, water resistant insulated Stranded 500', 1000' AND 2500' REELS Used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications. May be used in dry and damp locations at temperatures not to exceed 90 C, or in wet locations at temperatures not to exceed 75 C. Rated for 600 V The insulation is flame-retardant, moisture-resistant thermoset Available in sizes from 14 AWG 2000 kcmil Slick nylon outer jacket for easy pulling Copper based Custom colors UL44 / VW1 Federal Specification A-A ASTM - B3, B8 B787 NEMA WC 70/ICEA S NOM-ANCE 90 C NEC, NFPA Edition RoHS/REACH Compliant 500' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Grey Pink Purple / / / / BUILDING WIRE 16 BORDER STATES

17 XHHW cross-linked, high heat, water resistant insulated Stranded (continued) 500', 1000' AND 2500' REELS Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Gray Pink Purple / / / / ' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Gray Pink Purple / / / / BUILDING WIRE WIRE AND 17

18 NM NM-B non-metallic branch sheathed Solid Copper 250' REEL Utilizes non-metallic sheath and is commonly used for residential fixtures, switches, and loads rated for at least 90 C. NM ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical Code. Rated for 600 V Rated for exposed and concealed work in normally dry locations Copper based UL-83, UL-719 Federal Specification A-A ASTM-B3 and B8 NFPA 70, NEC Article 334 ARRA 2009; Section 1605 Buy American Compliant BUILDING WIRE Gauge # of Conductors Ground Size Ground Color BSE Part # Without Ground With Ground Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper BORDER STATES

19 NM NM-B non-metallic branch sheathed Solid Copper Utilizes non-metallic sheath and is commonly used for residential fixtures, switches, and loads rated for at least 90 C. NM ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical Code. Rated for 600 V Rated for exposed and concealed work in normally dry locations Copper based UL-83, UL-719 Federal Specification A-A ASTM-B3 and B8 NFPA 70, NEC Article 334 ARRA 2009; Section 1605 Buy American Compliant Gauge # of Conductors Ground Size Ground Color BSE Part # Without Ground With Ground Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper BUILDING WIRE WIRE AND 19

20 NM UFNMC-B non-metallic underground feeder and branch Solid Copper 250' REEL Utilizes non-metallic sheath and is commonly used for residential fixtures, switches, and loads rated for at least 90 C. Type NM ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical Code. Rated for 600 V Rated for exposed and concealed work in normally dry locations Copper based UL-83, UL-719 Federal Specification A-A ASTM-B3 and B8 NFPA 70, NEC Article 334 ARRA 2009; Section 1605 Buy American Compliant Gauge # of Conductors Ground Size Ground Color BSE Part # Without Ground With Ground Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper BUILDING WIRE 20 BORDER STATES

21 NM UFNMC-B non-metallic underground feeder and branch Solid Copper Utilizes non-metallic sheath and is commonly used for residential fixtures, switches, and loads rated for at least 90 C. Type NM ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical Code. Rated for 600 V Rated for exposed and concealed work in normally dry locations Copper based UL-83, UL-719 Federal Specification A-A ASTM-B3 and B8 NFPA 70, NEC Article 334 ARRA 2009; Section 1605 Buy American Compliant Gauge # of Conductors Ground Size Ground Color BSE Part # Without Ground With Ground Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper BUILDING WIRE WIRE AND 21

22 USE-2/RHW/RHW-2 underground service entrance/rubber insulated/wet locations Stranded 500' AND S Underground service entrance cable suitable in conduit or as a direct-buried installation. These are three distinct types of cable, listed in NFPA-70 (2014), most cable manufacturers have combined the ratings for these three types as they are so similar. It also offers the ability to re-purpose the cable as required and permitted by the NEC. Rated for 600 V Maximum operating temperature of 90 C in wet or dry locations Copper based UL-44, UL-854, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) Federal Specification A-A NEMA WC70/ICEA S , NEMA RV NEC, NFPA 70 ICEA T (210,000 Btu/hr) Flame Test ARRA 2009; Section 1605 Buy American Compliant 500' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Gray Purple Pink BUILDING WIRE Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Gray Purple Pink / / / / BORDER STATES

23 SER service entrance rounded Bare Copper 500' AND S Designed for above-ground use to connect the service drop to the meter, and from the meter to the breaker panel. There are two styles of type SE cable, SER and SEU. SER style has two, three or four phase conductors and a bare neutral. Rated for 600 V May be used in applications that require a flameresistant, moisture-resistant covering Copper based UL 83 for THHN/THWN-2, UL 44 for XHHW-2 Federal Specification A-A ASTM B-800 and B-801 NEC, NFPA 70 RoHS Compliant 500' REEL Gauge Ground Type Ground Size Ground Color BSE Part # 1/0-1/0-1/0-2 Copper 2 Bare CU Copper 3 Bare /0-2/0-2/0-1 Copper 1 Bare Copper 4 Bare /0-3/0-3/0-1/0 Copper 1/0 Bare Copper 5 Bare Copper 6 Bare Copper 6 Bare Gauge Ground Type Ground Size Ground Color BSE Part # 1/0-1/0-1/0-1/0-2 Copper 2 Bare /0-1/0-1/0-2 Copper 2 Bare CU Copper 3 Bare /0-2/0-2/0-1 Copper 1 Bare Copper 4 Bare /0-3/0-3/0-1/0 Copper 1/0 Bare Copper 5 Bare /0-4/0-4/0-2/0 Copper 2/0 Bare Copper 6 Bare Copper 6 Bare BUILDING WIRE WIRE AND 23

24 SEU service entrance unarmored Bare Copper 500' AND S Designed for above-ground use to connect the service drop to the meter, and from the meter to the breaker panel. There are two styles of type SE cable, SER and SEU. SEU style has two phase conductors surrounded by a concentric neutral. Rated for 600 V May be used in applications that require a flameresistant, moisture-resistant covering Copper based UL 83 for THHN/THWN-2, UL 44 for XHHW-2 Federal Specification A-A ASTM B-800 and B-801 NEC, NFPA 70 RoHS Compliant 500' REEL Gauge Ground Type Ground Size Type BSE Part # 1/0-1/0-1/0 Copper 1/0 Bare /0-2/0-2/0 Copper 2/0 Bare Copper 2 Bare Copper 4 Bare Copper 3 Bare Copper 5 Bare Copper 4 Bare Copper 6 Bare Copper 6 Bare Copper 8 Bare Copper 8 Bare BUILDING WIRE Gauge Ground Type Ground Size Type BSE Part # 1/0-1/0-1/0 Copper 1/0 Bare /0-2/0-2/0 Copper 2/0 Bare Copper 2 Bare Copper 4 Bare Copper 3 Bare Copper 5 Bare Copper 4 Bare Copper 6 Bare Copper 6 Bare Copper 8 Bare Copper 8 Bare BORDER STATES

25 MC SOLID AL SG metal-clad solid aluminum smart ground Solid 120 V 250' COIL Used for services, feeders, and branch circuits in industrial, commercial and multi-residential buildings. Used for power, lighting, control and signal circuits, indoors or outdoors and exposed or concealed. Used in raceways, and, where identified for such use, it can be direct buried and in cable trays. Used in wet locations as long as a corrosion-resistant jacket is provided over the metallic covering with one of the following conditions; the metallic covering is impervious to moisture, a moisture-resistant jacket is located under the cover, or the insulated conductors are listed for wet locations. Can be used in hazardous locations where specifically permitted by the NEC (NFPA-70) Permitted to be used in dry locations and embedded in plaster finish on brick or masonry except in damp or wet locations Care must be taken to minimize induced voltage on the metallic sheath MC cable conductors can be constructed of copper, aluminum, copper clad aluminum, nickel or nickel-coated copper, solid or stranded Maximum operating temperature of 90 C Copper based Custom colors UL 83, UL 1569, UL 1685 Federal Specification A-A59544 FT4/IEEE 1202 NEC, NFPA-70 Gauge # of Conductors Voltage Black/White Black/Red Red/White Blue/White Black/White/ Red Black/Blue/ White Red/Blue/ White Black/White/ Red/Blue Black/Red/ Blue/White BUILDING WIRE WIRE AND 25

26 MC SOLID AL SG metal-clad solid aluminum smart ground Solid 277 V 250' COIL Used for services, feeders, and branch circuits in industrial, commercial and multi-residential buildings. Used for power, lighting, control and signal circuits, indoors or outdoors and exposed or concealed. Used in raceways, and, where identified for such use, it can be direct buried and in cable trays. Used in wet locations as long as a corrosion-resistant jacket is provided over the metallic covering with one of the following conditions; the metallic covering is impervious to moisture, a moisture-resistant jacket is located under the cover, or the insulated conductors are listed for wet locations. Can be used in hazardous locations where specifically permitted by the NEC (NFPA-70) Permitted to be used in dry locations and embedded in plaster finish on brick or masonry except in damp or wet locations Care must be taken to minimize induced voltage on the metallic sheath MC cable conductors can be constructed of copper, aluminum, copper clad aluminum, nickel or nickel-coated copper, solid or stranded Maximum operating temperature of 90 C Copper based Custom colors UL 83, UL 1569, UL 1685 Federal Specification A-A59544 FT4/IEEE 1202 NEC, NFPA-70 Orange/ Brown/Yellow/ Brown/Orange/ Brown/Yellow/ Brown/Orange/ Gauge # of Conductors Voltage Yellow/Gray Orange/Gray Brown/Gray Purple/Gray Yellow/Gray Gray Gray Purple/Gray Yellow/Gray BUILDING WIRE 26 BORDER STATES

27 MC HCF SOL AL SG metal-clad health care solid aluminum smart ground Solid 120 V 250' COIL Permitted use for services, feeders, and branch circuits in industrial, commercial and multi-residential buildings. Acceptable for power, lighting, control and signal circuits, indoors or outdoors, and exposed or concealed. Used in raceways, and, where identified for such use, it can be direct buried and in cable trays. Used in hazardous locations where specifically permitted by the NEC (NFPA-70). Permitted to be used in dry locations and embedded in plaster finish on brick or masonry except in damp or wet locations. Used in wet locations as long as a corrosion-resistant jacket is provided over the metallic covering with one of the following conditions: the metallic covering is impervious to moisture, a moisture-resistant jacket is located under the cover, or the insulated conductors are listed for wet locations. Care must be taken to minimize induced voltage on the metallic sheath Can be constructed of copper, aluminum, copper clad aluminum, nickel or nickel-coated copper, solid or stranded The maximum operating temperature of 90 C Copper based Custom colors NEC, NFPA-70 UL 83, UL 1569, UL 1685 Federal Specification A-A59544 FT4/IEEE 1202 Gauge # of Conductors Voltage Black/White Black/Red Red/White Blue/White Black/White/ Red Black/Blue/ White Red/Blue/ White Black/White/ Red/Blue Black/Red/ Blue/White BUILDING WIRE WIRE AND 27

28 MC HCF SOL AL SG metal-clad health care solid aluminum smart ground Solid 277 V 250' COIL Permitted use for services, feeders, and branch circuits in industrial, commercial and multi-residential buildings. Acceptable for power, lighting, control and signal circuits, indoors or outdoors, and exposed or concealed. Used in raceways, and, where identified for such use, it can be direct buried and in cable trays. Used in hazardous locations where specifically permitted by the NEC (NFPA-70). Permitted to be used in dry locations and embedded in plaster finish on brick or masonry except in damp or wet locations. Used in wet locations as long as a corrosion-resistant jacket is provided over the metallic covering with one of the following conditions: the metallic covering is impervious to moisture, a moisture-resistant jacket is located under the cover, or the insulated conductors are listed for wet locations. Care must be taken to minimize induced voltage on the metallic sheath Can be constructed of copper, aluminum, copper clad aluminum, nickel or nickel-coated copper, solid or stranded The maximum operating temperature of 90 C Copper based Custom colors NEC, NFPA-70 UL 83, UL 1569, UL 1685 Federal Specification A-A59544 FT4/IEEE 1202 Orange/ Brown/Yellow/ Brown/Orange/ Brown/Yellow/ Brown/Orange/ Gauge # of Conductors Voltage Yellow/Gray Orange/Gray Brown/Gray Purple/Gray Yellow/Gray Gray Gray Purple/Gray Yellow/Gray BUILDING WIRE 28 BORDER STATES

29 MC STRANDED AL SG metal-clad stranded aluminum smart ground XHHW Stranded 120 V 250' COIL Used for services, feeders, and branch circuits in industrial, commercial and multi-residential buildings. For power, lighting, control and signal circuits, indoors or outdoors, and exposed or concealed. Used in raceways, and, where identified for such use, it can be direct buried and in cable trays. Used in hazardous locations where specifically permitted by the NEC (NFPA-70). Permitted to be used in dry locations and embedded in plaster finish on brick or masonry except in damp or wet locations. Used in wet locations as long as a corrosion-resistant jacket is provided over the metallic covering with one of the following conditions: the metallic covering is impervious to moisture, a moisture-resistant jacket is located under the cover, or the insulated conductors are listed for wet locations. Care must be taken to minimize induced voltage on the metallic sheath MC cable conductors can be constructed of copper, aluminum, copper clad aluminum, nickel or nickel-coated copper, solid or stranded The maximum operating temperature of 90 C Copper based Custom colors NEC, NFPA-70 UL 83, UL 1569, UL 1685 Federal Specification A-A59544 FT4/IEEE 1202 # of Ground Ground Black/White/ Black/Blue/ Red/Blue/ Black/White/ Black/Red/ Gauge Conductors Voltage Ground Size Color Black/White Black/Red Red/White Blue/White Red White White Red/Blue Blue/White Copper 14 Green Copper 12 Green Copper 10 Green Copper 14 Green Copper 12 Green Copper 10 Green Copper 14 Green Copper 12 Green Copper 10 Green BUILDING WIRE WIRE AND 29

30 MC STRANDED AL SG metal-clad stranded aluminum smart ground XHHW Stranded 277 V 250' COIL Used for services, feeders, and branch circuits in industrial, commercial and multi-residential buildings. For power, lighting, control and signal circuits, indoors or outdoors, and exposed or concealed. Used in raceways, and, where identified for such use, it can be direct buried and in cable trays. Used in hazardous locations where specifically permitted by the NEC (NFPA-70). Permitted to be used in dry locations and embedded in plaster finish on brick or masonry except in damp or wet locations. Used in wet locations as long as a corrosion-resistant jacket is provided over the metallic covering with one of the following conditions: the metallic covering is impervious to moisture, a moisture-resistant jacket is located under the cover, or the insulated conductors are listed for wet locations. Care must be taken to minimize induced voltage on the metallic sheath MC cable conductors can be constructed of copper, aluminum, copper clad aluminum, nickel or nickel-coated copper, solid or stranded The maximum operating temperature of 90 C Copper based Custom colors NEC, NFPA-70 UL 83, UL 1569, UL 1685 Federal Specification A-A59544 FT4/IEEE 1202 Gauge # of Strands # of Conductors Voltage Ground Ground Size Ground Color Yellow/ Gray Orange/ Gray Brown/ Gray Purple/ Gray Copper 14 Green Copper 12 Green Copper 10 Green Copper 14 Green Copper 12 Green Copper 10 Green Copper 14 Green Copper 12 Green Copper 10 Green Orange/ Yellow/ Gray Brown/ Yellow/ Gray Brown/ Orange/ Gray Brown/ Yellow/ Purple/ Gray Brown/ Orange/ Yellow/Gray BUILDING WIRE 30 BORDER STATES

31 TRACER Solid 30 V 500' REEL Used in the detection of underground piping and other underground utility installations. Suitable for direct burial in wet or dry locations. 30 V styles have a 30 mil insulation wall; 600 V styles have a 45 mil insulation wall Comes in solid or stranded uncoated copper conductors Typically provided with polyethylene (LLDP) insulation Rated 90 C wet or dry Copper based UL-83, UL-1581 ASTM B3; B8; B787 ASTM Stranding Class B3; B8; B787 RoHS Compliant Gauge Voltage Green Blue Red Yellow Orange Solid 600 V 500' REEL Used in the detection of underground piping and other underground utility installations. Suitable for direct burial in wet or dry locations. 30 V styles have a 30 mil insulation wall; 600 V styles have a 45 mil insulation wall Comes in solid or stranded uncoated copper conductors Typically provided with polyethylene (LLDP) insulation Rated 90 C wet or dry Copper based UL-83, UL-1581 ASTM B3; B8; B787 ASTM Stranding Class B3; B8; B787 RoHS Compliant Gauge Voltage Green Blue Red Yellow Orange BUILDING WIRE WIRE AND 31

32 TRACER Stranded 30 V 500' REEL Used in the detection of underground piping and other underground utility installations. Suitable for direct burial in wet or dry locations. 30 V styles have a 30 mil insulation wall; 600 V styles have a 45 mil insulation wall Comes in solid or stranded uncoated copper conductors Typically provided with polyethylene (LLDP) insulation Rated 90 C wet or dry Copper based UL-83, UL-1581 ASTM B3; B8; B787 ASTM Stranding Class B3; B8; B787 RoHS Compliant Gauge # of Strands Voltage Green Blue Red Yellow Orange Stranded 600 V 500' REEL Used in the detection of underground piping and other underground utility installations. Suitable for direct burial in wet or dry locations. 30 V styles have a 30 mil insulation wall; 600 V styles have a 45 mil insulation wall Comes in solid or stranded uncoated copper conductors Typically provided with polyethylene (LLDP) insulation Rated 90 C wet or dry Copper based UL-83, UL-1581 ASTM B3; B8; B787 ASTM Stranding Class B3; B8; B787 RoHS Compliant BUILDING WIRE Gauge # of Strands Voltage Green Blue Red Yellow Orange BORDER STATES

33 PV photovoltaic 600 V 500' AND S Suitable for use in solar power applications and for exposed or concealed wiring in wet or dry locations. This is a relatively new product group and various manufacturers may have widely varying offerings. Rated for direct burial. 600 V Maximum operating temperature of 90 C Copper based UL 4703, UL-854, UL-44, UL 1685-FT4/ IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), UL-854, UL-4703 and UL-44 ASTM-B787 and ASTM-B8 NEC, NFPA ' REEL Gauge Voltage Insulation Black XLPE XLPE XLPE XLPE XLPE Gauge Voltage Insulation Black XLPE XLPE XLPE XLPE XLPE XLPE /0 600 XLPE /0 600 XLPE /0 600 XLPE /0 600 XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE BUILDING WIRE WIRE AND 33

34 PV photovoltaic 1 kv 2 kv 500' AND S Suitable for use in solar power applications and for exposed or concealed wiring in wet or dry locations. This is a relatively new product group and various manufacturers may have widely varying offerings. Rated for direct burial. 1 kv 2 kv Maximum operating temperature of 90 C Copper based UL 4703, UL-854, UL-44, UL 1685-FT4/ IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), UL-854, UL-4703 and UL-44 ASTM-B787 and ASTM-B8 NEC, NFPA ' REEL Gauge Voltage Insulation Black 18 1 kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE BUILDING WIRE Gauge Voltage Insulation Black 8 1 kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE /0 1 kv 2 kv XLPE /0 1 kv 2 kv XLPE /0 1 kv 2 kv XLPE /0 1 kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE kv 2 kv XLPE BORDER STATES

35 BARE Solid 500' AND S Solid (classes AA and A) bare copper is suitable for overhead transmission and distribution applications. Only circuit wire is available in 500' reel Copper based ASTM-B3, ASTM-B8 ASTM-B787, ASTM B1, ASTM B-2, ASTM B ' REEL Gauge Type 500' Reel Soft Drawn Bare 18 Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Hard Drawn 6 Bare Copper Bare Copper Bare Copper /0 Bare Copper Medium Hard Drawn 6 Bare Copper Soft Drawn 2 Tinned Copper Gauge Type 1000' Reel Soft Drawn Bare 10 Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Hard Drawn 6 Bare Copper Bare Copper Bare Copper /0 Bare Copper Medium Hard Drawn 6 Bare Copper Soft Drawn 2 Tinned Copper BUILDING WIRE WIRE AND 35

36 BARE Stranded 500' AND S Stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications. Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook-up, jumpers, and grounds in electrical construction. Available in sizes #14 AWG 1000 kcmil Copper based ASTM-B3, ASTM-B8 ASTM-B787, ASTM B1, ASTM B-2, ASTM B ' REEL BUILDING WIRE Gauge # of Strands Type 500' Reel Soft Drawn Bare 8 7 Bare Copper Bare Copper Bare Copper Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper Bare Copper Bare Copper Bare Copper /0 19 Bare Copper /0 19 Bare Copper /0 19 Bare Copper /0 19 Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Hard Drawn 4 7 Bare Copper Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper BORDER STATES

37 BARE Stranded (continued) 500' AND S 500' REEL Gauge # of Strands Type 500' Reel Hard Drawn (continued) 4/0 19 Bare Copper Bare Copper Medium Hard Drawn 2 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 19 Bare Copper Bare Copper Soft Drawn 1/0 19 Tinned copper /0 19 Tinned copper /0 37 Tinned copper Gauge # of Strands Type 1000' Reel Soft Drawn Bare 8 7 Bare Copper Bare Copper Bare Copper Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper Bare Copper Bare Copper Bare Copper /0 19 Bare Copper /0 19 Bare Copper /0 19 Bare Copper /0 19 Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Bare Copper Hard Drawn 4 7 Bare Copper BUILDING WIRE WIRE AND 37

38 BARE Stranded (continued) 500' AND S Gauge # of Strands Type 500' Reel Hard Drawn (continued) 2 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 19 Bare Copper Bare Copper Medium Hard Drawn 2 7 Bare Copper /0 7 Bare Copper /0 7 Bare Copper /0 19 Bare Copper Bare Copper Soft Drawn 1/0 19 Tinned copper /0 19 Tinned copper /0 37 Tinned copper CoilPAKs and PULLPros are great for service work or large projects and eliminate the need for wire trees to complete your pulls, saving you time and money. BUILDING WIRE 38 BORDER STATES

39 In this section Tray Instrumentation Control Power limited tray cable Power control cable Power control VFD cable WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

40 A mobile WAREHOUSE at your FINGERTIPS Because your project depends on having products where you need them, when you need them. CONTACT BORDER STATES for information on our jobsite trailers. Proudly supplying products and services to the construction, industrial and utility industries. borderstates.com ( )

41 INSTRUMENTATION TFFN Jacket Unshielded Used on class 1 remote-control and signaling circuits. For use indoors, outdoors, direct burial, free air, raceways, encased in concrete, open trays, troughs or continuous rigid cable supports. Can be used in Class I, Div. 2, hazardous locations, and as a non-power-limited fire alarm circuit cable (NPLF) per NEC Article 760. Provides sunlight, cold bend and cold impact resistance Maximum operating temperature of 90 C Copper based Custom colors UL 83, UL 1277, UL 1581, UL UL Flame Exposure Test (70,000 Btu/hr) ICEA T Vertical Cable Tray Flame Test (70,000 Btu/hr) IEEE 1202 Gauge # of Conductors Voltage BSE Part # PVC Insulation, TFFN Jacket, Without Ground TRAY WIRE AND 41

42 INSTRUMENTATION TFFN Jacket Shielded Used on class 1 remote-control and signaling circuits. For use indoors, outdoors, direct burial, free air, raceways, encased in concrete, open trays, troughs or continuous rigid cable supports. Can be used in Class I,Div. 2, hazardous locations, and as a non-power-limited fire alarm circuit cable (NPLF) per NEC Article 760. Provides sunlight, cold bend and cold impact resistance Maximum operating temperature of 90 C Copper based Custom colors UL 83, UL 1277, UL 1581, UL UL Flame Exposure Test (70,000 Btu/hr) ICEA T Vertical Cable Tray Flame Test (70,000 Btu/hr) IEEE 1202 TRAY Gauge # of Conductors Voltage Ground Size BSE Part # PVC Insulation, TFFN Jacket, Without Ground BORDER STATES

43 INSTRUMENTATION TFFN Jacket Shielded (continued) Gauge # of Conductors Voltage Ground Size BSE Part # Overall Shielded (OAS), PVC Insulation, TFFN Jacket, Without Ground Overall Shielded (OAS), PVC Insulation, TFFN Jacket, Tinned Copper Ground 18 1Pair Triad Triad Triad Triad Triad Pair Pair Pair Pair Single Pair Overall Shielded (SPOS), PVC Insulation, TFFN Jacket, Tinned Copper Ground 18 2Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair TRAY WIRE AND 43

44 CONTROL Unshielded A cable used on class 1 remote-control and signaling circuits. For use indoors, outdoors, direct burial, free air, raceways, encased in concrete, open trays, troughs or continuous rigid cable supports. Can be used in Class I, Div. 2, hazardous locations and as a non-power-limited fire alarm circuit cable (NPLF) per NEC Article 760. Provides sunlight, cold bend and cold impact resistance Maximum operating temperature of 90 C Copper based Custom colors UL 83, UL 1277, UL 1581, UL UL Flame Exposure Test (70,000 Btu/hr) ICEA T Vertical Cable Tray Flame Test (70,000 Btu/hr) IEEE 1202 TRAY Gauge # of Conductors Voltage Ground Ground Size Ground Color Gray Black PVC Jacket, Without Ground Without Without Without PVC Jacket, With Ground Copper 20 Green/Yellow Copper 20 Green/Yellow Copper 20 Green/Yellow Copper 20 Green/Yellow Copper 20 Green/Yellow Copper 20 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow BORDER STATES

45 CONTROL Unshielded (continued) Gauge # of Conductors Voltage Ground Ground Size Ground Color Gray Black PVC Jacket, With Ground Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow PVC Jacket, Exposed Run (ER), Without Ground Without Without PVC Jacket, Exposed Run (ER), With Ground Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 12 Green/Yellow Copper 12 Green/Yellow Copper 12 Green/Yellow Copper 12 Green/Yellow Copper 10 Green/Yellow Copper 10 Green/Yellow Copper 10 Green/Yellow Copper 10 Green/Yellow Copper 8 Green/Yellow Copper 8 Green/Yellow Copper 8 Green/Yellow TRAY WIRE AND 45

46 CONTROL Shielded A cable used on class 1 remote-control and signaling circuits. For use indoors, outdoors, direct burial, free air, raceways, encased in concrete, open trays, troughs or continuous rigid cable supports. Can be used in Class I, Div. 2, hazardous locations and as a non-power-limited fire alarm circuit cable (NPLF) per NEC Article 760. Provides sunlight, cold bend and cold impact resistance Maximum operating temperature of 90 C Copper based Custom colors UL 83, UL 1277, UL 1581, UL UL Flame Exposure Test (70,000 Btu/hr) ICEA T Vertical Cable Tray Flame Test (70,000 Btu/hr) IEEE 1202 Gauge # of Conductors Voltage Ground Ground Size Ground Color Gray Black PVC Copper 20 Green/Yellow Copper 18 Green/Yellow Copper 18 Green/Yellow Copper 16 Green/Yellow Copper 16 Green/Yellow PVC, Exposed Run (ER) Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 14 Green/Yellow Copper 12 Green/Yellow Copper 12 Green/Yellow Copper 12 Green/Yellow Copper 10 Green/Yellow Tinned Copper, XLPE/PVC, Exposed Run (ER) Tinned Copper 14 Green/Yellow Tinned Copper 12 Green/Yellow Tinned Copper 10 Green/Yellow Tinned Copper 8 Green/Yellow TRAY 46 BORDER STATES

47 CONTROL THHN Jacket Unshielded For use in industrial power or control circuits where multiple conductors are used for transmission of various signal and power requirements. The majority of these cables are used in electric utility and heavy industrial applications; including relaying, control circuits, telemetering, and indicating and measuring. Normal applications are in free air, raceways, or direct burial; in wet or dry locations; permitted for use in Class I, Div. 2 industrial hazardous locations per NEC article 501 and Class 1 circuits per NEC. Color coding of the conductors is, typically, in accordance with one of the tables in Appendix E of ICEA S Flexibility and cold bend capabilities are important features of this cable Maximum temperature is 90 C, wet or dry conditions Copper based Custom colors UL 1277, UL 1581, UL 1685 ICEA T ASTM - All Applicable Standards IEEE 1202/FT4 ICEA S Gauge # of Conductors Voltage Ground Ground Size Ground Color BSE Part # PVC Insulation, THHN Jacket, Without Ground TRAY WIRE AND 47

48 CONTROL THHN Jacket Unshielded (continued) Gauge # of Conductors Voltage Ground Ground Size Ground Color BSE Part # PVC Insulation, THHN Jacket, Without Ground PVC Insulation, THHN Jacket, Green Ground Bare Copper 14 Green Bare Copper 14 Green Bare Copper 12 Green Bare Copper 12 Green Bare Copper 10 Green Bare Copper 10 Green Bare Copper 10 Green Bare Copper 10 Green Bare Copper 10 Green PVC Insulation, THHN Jacket, Bare Ground Bare Copper 12 Bare Bare Copper 12 Bare TRAY 48 BORDER STATES

49 CONTROL THHN Jacket Shielded For use in industrial power or control circuits where multiple conductors are used for transmission of various signal and power requirements. The majority of these cables are used in electric utility and heavy industrial applications; including relaying, control circuits, telemetering, and indicating and measuring. Normal applications are in free air, raceways, or direct burial; in wet or dry locations; permitted for use in Class I, Div. 2 industrial hazardous locations per NEC article 501 and Class 1 circuits per NEC. Color coding of the conductors is, typically, in accordance with one of the tables in Appendix E of ICEA S Flexibility and cold bend capabilities are important features of this cable Maximum temperature is 90 C, wet or dry conditions Copper based Custom colors UL 1277, UL 1581, UL 1685 ICEA T ASTM - All Applicable Standards IEEE 1202/FT4 ICEA S Gauge # of Conductors Voltage BSE Part # PVC Insulation, THHN Jacket, Without Ground TRAY WIRE AND 49

50 CONTROL XHHW Jacket Unshielded For use in industrial power or control circuits where multiple conductors are required for transmission of various signal and power requirements. The majority of these cables are used in electric utility and heavy industrial applications; including relaying, control circuits, telemetering, and indicating and measuring. Normal applications are in free air, raceways, or direct burial; in wet or dry locations; permitted for use in Class I, Div. 2 industrial hazardous locations per NEC article 501 and Class 1 circuits per NEC. Color coding of the conductors is, typically, in accordance with one of the tables in Appendix E of ICEA S Flexibility and cold bend capabilities are important features of this cable Most are rated to operate at a maximum temperature of 90 C, wet or dry conditions Copper based Custom colors UL 1277, UL 1581, UL 1685 ICEA T ASTM - All Applicable Standards IEEE 1202/FT4 ICEA S TRAY Gauge # of Conductors Voltage Ground Ground Size Ground Color BSE Part # PVC Insulation, XHHW Jacket, Without Ground 14 2Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair BORDER STATES

51 CONTROL XHHW Jacket Unshielded (continued) Gauge # of Conductors Voltage Ground Ground Size Ground Color BSE Part # PVC Insulation, XHHW Jacket, Without Ground 10 7Pair Pair Pair Pair Pair Pair Pair PVC Insulation, XHHW Jacket, Green Ground Bare Copper 14 Green Bare Copper 12 Green Bare Copper 10 Green Bare Copper 10 Green Bare Copper 10 Green PVC Insulation, XHHW Jacket, Bare Ground Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 14 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 12 Bare Bare Copper 10 Bare Bare Copper 10 Bare Bare Copper 10 Bare Bare Copper 10 Bare Bare Copper 10 Bare Bare Copper 10 Bare Bare Copper 10 Bare TRAY WIRE AND 51

52 POWER LIMITED TRAY Unshielded Suited to instrumentation applications requiring sunlight, moisture and vapor resistance. Commonly used in power-limited circuits and for applications in the mass transit industry; including, burglar alarms, computer interconnects, business machines, intercom systems and cash registers. Used for control signals transmitted at over 100 millivolts. Available as a shielded or unshielded product Temperature range of -20º 105 C Copper based Custom colors UL 1685 IEEE 1202/383 NEC Article 725 Gauge # of Conductors Voltage Color BSE Part # Copper, PVC Gray Gray Gray Gray Gray Gray Gray TRAY 52 BORDER STATES

53 POWER LIMITED TRAY THHN Jacket Shielded Suited to instrumentation applications requiring sunlight, moisture and vapor resistance. It is commonly used in power-limited circuits and for applications in the mass transit industry; including, burglar alarms, computer interconnects, business machines, intercom systems and cash registers. Used for control signals transmitted at over 100 millivolts. Available as a shielded or unshielded product Temperature range of -20º 105 C Copper based Custom colors UL 1685 IEEE 1202/383 NEC Article 725 Gauge # of Conductors Voltage BSE Part # Single Pair Overall Shielded (SPOS), 7 Stranded, Copper, THHN Insulation, PVC Jacket 20 2Pair Pair Pair Pair Pair Pair Pair TRAY WIRE AND 53

54 POWER LIMITED TRAY TFFN Jacket Shielded Suited to instrumentation applications requiring sunlight, moisture and vapor resistance. Commonly used in power-limited circuits and for applications in the mass transit industry; including, burglar alarms, computer interconnects, business machines, intercom systems and cash registers. Used for control signals transmitted at over 100 millivolts. Available as a shielded or unshielded product Temperature range of -20º 105 C Copper based Custom colors UL 1685 IEEE 1202/383 NEC Article 725 Gauge # of Conductors Voltage BSE Part # Single Pair Overall Shielded (SPOS), 7 Stranded, Copper, TFFN Insulation, PVC Jacket 18 2Pair Pair Pair Pair Single Triad Overall Shielded (STOS), 7 Stranded, Copper, TFFN Insulation, PVC Jacket 16 2Triad Triad Triad TRAY 54 BORDER STATES

55 POWER CONTROL THHN Jacket Unshielded Used to provide power to low voltage devices from a central control point. Installed in raceways, conduit, cable trays and outdoor locations. Suitable for direct burial. Maximum operating temperature of 75 C in wet locations and 90 C in dry locations Copper based Custom colors UL 1277, UL 1581, UL 1685 ICEA S IEEE 383 Gauge # of Conductors Voltage Ground Ground Size Ground Color BSE Part # THHN Insulation, PVC Jacket, Without Ground Bare Bare Bare Bare Bare Bare / Bare PVC Jacket, Copper Green Ground Copper 8 Green Copper 8 Green Copper 8 Green PVC Jacket, Copper Bare Ground Copper 8 Bare Copper 8 Bare Copper 8 Bare Copper 8 Bare Copper 6 Bare Copper 6 Bare Copper 6 Bare Copper 6 Bare Copper 6 Bare / Copper 6 Bare / Copper 6 Bare / Copper 6 Bare / Copper 6 Bare / Copper 4 Bare / Copper 4 Bare / Copper 4 Bare / Copper 4 Bare Copper 4 Bare Copper 4 Bare Copper 3 Bare Copper 3 Bare Copper 3 Bare Copper 2 Bare Copper 2 Bare Copper 2 Bare Copper 1 Bare Copper 1 Bare TRAY WIRE AND 55

56 POWER CONTROL XHHW Jacket Unshielded Used to provide power to low voltage devices from a central control point. Installed in raceways, conduit, cable trays and outdoor locations. Suitable for direct burial. Maximum operating temperature of 75 C in wet locations and 90 C in dry locations Copper based Custom colors UL 1277, UL 1581, UL 1685 ICEA S IEEE 383 Gauge # of Conductors Voltage Ground Ground Size Ground Color BSE Part # PVC Jacket, Without Ground 6 3Pair Pair Pair Pair Pair Pair Pair /0 3Pair /0 4Pair /0 3Pair /0 4Pair /0 3Pair /0 4Pair /0 3Pair /0 4Pair Pair Pair Pair Pair Pair Pair TRAY 56 BORDER STATES

57 POWER CONTROL XHHW Jacket Unshielded (continued) Gauge # of Conductors Voltage Ground Ground Size Ground Color BSE Part # PVC Jacket, With Ground Copper 8 Bare Copper 8 Bare Copper 8 Bare Copper 8 Bare Copper 6 Bare Copper 6 Bare Copper 6 Bare / Copper 6 Bare / Copper 6 Bare / Copper 6 Bare / Copper 6 Bare / Copper 4 Bare / Copper 4 Bare / Copper 4 Bare / Copper 4 Bare Copper 4 Bare Copper 4 Bare Copper 2 Bare Copper 2 Bare Copper 1 Bare Copper 1 Bare TRAY WIRE AND 57

58 POWER CONTROL VFD VFD Shielded Copper Used to provide power to low voltage devices from a central control point. Installed in raceways, conduit, cable trays and outdoor locations. Suitable for direct burial. Maximum operating temperature of 75 C in wet locations and 90 C in dry locations Copper based Custom colors UL 1277, UL 1581, UL 1685 ICEA S IEEE 383 Gauge # of Conductors Voltage Ground Ground Size Ground Color Black Gray Copper, PVC Jacket, ER Rated (Exposed Run) Copper 6 Green/Yellow Copper 6 Green/Yellow Copper 6 Green/Yellow Copper 4 Green/Yellow Copper 2 Green/Yellow Copper 2 Green/Yellow Copper 1 Green/Yellow VFD Shielded Tinned Copper Used to provide power to low voltage devices from a central control point. Installed in raceways, conduit, cable trays and outdoor locations. Suitable for direct burial. Maximum operating temperature of 75 C in wet locations and 90 C in dry locations Copper based Custom colors UL 1277, UL 1581, UL 1685 ICEA S IEEE 383 BUILDING WIRE Gauge # of Conductors Voltage Ground Ground Size Ground Color Black Gray Tinned Copper, XLPE/PVC Jacket Tinned Copper 6 Green/Yellow Tinned Copper 4 Green/Yellow Tinned Copper 2 Green/Yellow BORDER STATES

59 In this section Medium VOLTAGE MV MV WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

60 MV-90 medium-voltage 90 max temperature rating Copper Unshielded, XLP Insulated Used as a main or primary power feeder for various types of applications and in substations and generating plants. Suitable for use in wet or dry locations at maximum operating temperature of 90 C for normal operation; 130 C for emergency overload conditions; and 250 C for short circuit conditions. Rated 5 kv to 15 kv, 100% insulation, 90 C in wet or dry locations Flame and sunlight resistant Shielded and normally has XLP insulation Unless otherwise specified, the outer jacket is PVC Available in aluminum or copper Copper based UL 1072, UL 1685 NFPA-70 (NEC) ICEA S (NEMA WC-74) AEIC CS-5 Gauge Voltage Insulation Jacket BSE Part # kv XLP PVC kv XLP PVC kv XLP PVC /0 2.4 kv XLP PVC /0 2.4 kv XLP PVC /0 2.4 kv XLP PVC kv XLP PVC kv XLP PVC kv XLP PVC kv XLP PVC Copper Unshielded, EPR Insulated MEDIUM VOLTAGE Used as a main or primary power feeder for various types of applications and in substations and generating plants. Suitable for use in wet or dry locations at maximum operating temperature of 90 C for normal operation; 130 C for emergency overload conditions; and 250 C for short circuit conditions. Rated 5 kv to 15 kv, 100% insulation, 90 C in wet or dry locations Flame and sunlight resistant Shielded and normally has XLP insulation Unless otherwise specified, the outer jacket is PVC Available in aluminum or copper Copper based UL 1072, UL 1685 NFPA-70 (NEC) ICEA S (NEMA WC-74) AEIC CS-5 Gauge Voltage Insulation Jacket BSE Part # kv EPR PVC kv EPR PVC kv EPR PVC BORDER STATES

61 MV-105 medium-voltage 105 max temperature rating Copper Shielded MCR 5 kv Used as a main or primary power feeder for various types of applications, and in substations and generating plants. Suitable for use in wet or dry locations at maximum operating temperature of 105 C for normal operation; 140 C for emergency overload conditions; and 250 C for short circuit conditions. Rated 5 kv to 15 kv, 133% insulation, 105 C in wet or dry locations Flame and sunlight resistant Shielded and normally has XLP insulation Unless otherwise specified, the outer jacket is PVC This cable is available in aluminum or copper Copper based UL 1072, UL 1685 NFPA-70 (NEC) ICEA S (NEMA WC-74) AEIC CS-5 Gauge Voltage Insulation Jacket BSE Part # 6 5 kv EPR PVC kv EPR PVC kv EPR PVC /0 5 kv EPR PVC /0 5 kv EPR PVC /0 5 kv EPR PVC /0 5 kv EPR PVC kv EPR PVC kv EPR PVC kv EPR PVC kv EPR PVC kv EPR PVC MEDIUM VOLTAGE WIRE AND 61

62 MV-105 medium-voltage 105 max temperature rating Copper Shielded MCR 15 kv Used as a main or primary power feeder for various types of applications, and in substations and generating plants. Suitable for use in wet or dry locations at maximum operating temperature of 105 C for normal operation; 140 C for emergency overload conditions; and 250 C for short circuit conditions. Rated 5 kv to 15 kv, 133% insulation, 105 C in wet or dry locations Flame and sunlight resistant Shielded and normally has XLP insulation Unless otherwise specified, the outer jacket is PVC This cable is available in aluminum or copper Copper based UL 1072, UL 1685 NFPA-70 (NEC) ICEA S (NEMA WC-74) AEIC CS-5 Gauge Voltage Insulation Jacket BSE Part # 2 15 kv EPR PVC kv EPR PVC /0 15 kv EPR PVC /0 15 kv EPR PVC /0 15 kv EPR PVC /0 15 kv EPR PVC kv EPR PVC kv EPR PVC kv EPR PVC kv EPR PVC kv EPR PVC Reel Deal Save up to 72% when we cut your wire pulls to length, install pulling heads and parallel your wire. Cuts job site waste with only one reel instead of four. MEDIUM VOLTAGE 62 BORDER STATES

63 Lead WIRE In this section SIS Hook-up MTW WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

64 SIS switchboard Stranded, XLP Insulated 500' REEL Used in switchboards, panel boards, Industrial control panels and many other applications up to 600 V. For use in Class 1E low voltage applications in operation and interconnection of protective devices where optimum performance is required. Standard construction is tinned stranded copper It is available in sizes from 4/0 #18 AWG, various strandings are available The most flexible stranding configuration is commonly referred to as SISF The insulation is XLPE, which is flame-retardant, heat, moisture and radiation resistant Maximum operating temperature of 90 C Most SIS wire is gray, but other colors are available. Specifically, red, blue, green, black and white Copper based UL 44, UL 1581, VW-1 ASTM - All Applicable Standards Gauge # of Strands Gray PROJECT MANAGEMENT SERVICES We make sure our customers have the right materials when and where they're needed. And they agree our project management services keep work crews going and plant turnarounds on schedule. Our customers store and secure material on site, minimize damage and reduce shrinkage. They meet material requirements for each phase of the job and ensure all things go according to plan. LEAD WIRE 64 BORDER STATES

65 HOOK-UP UL 1007 Used in a broad range of applications, including interconnection circuits, electrical harness fabrication and internal wiring for electronic equipment, appliances, motor leads and other equipment. Temperature range is C Tinned copper conductors PVC Insulation Copper based UL 1007 VW-1 Gauge Voltage UL Listing Black Green Blue Red White Brown Orange Yellow Gray Pink Purple Tan UL 1015 Used in a broad range of applications, including interconnection circuits, electrical harness fabrication and internal wiring for electronic equipment, appliances, motor leads and other equipment. Temperature range is C Tinned copper conductors PVC Insulation Copper based UL 1015 UL Type MTW VW-1 Gauge Voltage UL Listing Black Green Blue Red White Brown Orange Yellow Gray Pink Purple Tan LEAD WIRE WIRE AND 65

66 HOOK-UP UL 1015-H07V-K Used in a broad range of applications, including interconnection circuits, electrical harness fabrication and internal wiring for electronic equipment, appliances, motor leads and other equipment. Temperature range is C Tinned copper conductors PVC Insulation Copper based UL 1015-H07V-K UL Type MTW VW-1 Gauge Voltage UL Listing Black Green Blue Red White Brown Orange Yellow Gray Pink Purple Tan H07V-K UL MW-76 Used in a broad range of applications, including interconnection circuits, electrical harness fabrication and internal wiring for electronic equipment, appliances, motor leads and other equipment. Temperature range is C Tinned copper conductors PVC insulation, medium wall Flame and ozone resistant Inert to most chemicals, oils, and solvents Copper based UL MW-76 Gauge Voltage UL Listing Black Green Blue Red White Brown Orange Yellow Gray Pink Purple Tan MW LEAD WIRE 66 BORDER STATES

67 HOOK-UP UL Mil-W Used in a broad range of applications, including interconnection circuits, electrical harness fabrication and internal wiring for electronic equipment, appliances, motor leads and other equipment. Temperature range is C Tinned copper conductors PVC insulation Copper based UL Mil-W Gauge Voltage UL Listing Black Green Blue Red White Brown Orange Yellow Gray Pink Purple Tan Mil-W UL MW Used in a broad range of applications, including interconnection circuits, electrical harness fabrication and internal wiring for electronic equipment, appliances, motor leads and other equipment. Temperature range is C Tinned copper conductors PVC insulation, medium wall Flame and ozone resistant Inert to most chemicals, oils, and solvents Copper based UL MW Gauge Voltage UL Listing Black Green Blue Red White Brown Orange Yellow Gray Pink Purple Tan MW LEAD WIRE WIRE AND 67

68 MTW machine tool Stranded 500' AND 2500' REELS Used in utility substations. Rated for 600 V Flame-retardant, heat, moisture and oil resistant The insulation is PVC and is normally a solid color with a colored spiral stripe Maximum operating temperature of 90 C in dry locations and 60 C in wet locations Copper based Custom colors UL ' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Gray Pink Purple ' REEL Gauge # of Strands Black Green Blue Red White Brown Orange Yellow Grey Pink Purple LEAD WIRE 68 BORDER STATES

69 Armored In this section AIA AIA CAT 5E MC-HL MC-HL MOD BUS LV AirGuard Class 1 Div LV AirGuard Class 1 Div MC-HL Medium Volt Teck WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

70 LV AIRGUARD POWER S for Harsh Environments will not kink. No Knife? No Saw? No Problem! Low Voltage AIRGUARD cables are primarily designed for power, control, signal, and instrumentation applications in the harsh environments found in the heavy industrial and offshore markets. LV AIRGUARD has been designed to reduce installation costs in the field while improving the overall cable performance as compared to Type MC and MC-HL alternatives, which can often be costly, time consuming, and difficult to install. LV AIRGUARD is rated for installations in cable tray for exposed runs (Type TC-ER), conduit, and direct burial. It exceeds the stringent crush and impact resistance of UL 2225 for MC-HL cables and is permitted for use in Class I Division 1 and Zone 1 hazardous locations (TC-ER-HL) in accordance with National Electrical Code (2014) Sections (A)(2)(3) and (B)(i). Prysmian s patented AIRGUARD design affords far greater protection against water ingress and chemical attack than traditional MC armored cables. It also provides users the ease of installation of a tray cable while providing better mechanical and environmental protection than traditional metal clad cables. For 15 years, Medium Voltage AIRGUARD has been proven to outperform Metal Clad cables with better mechanical, chemical and installation performance. Now Prysmian s R&D group has extended that capability to our low voltage cables by designing LV AIRGUARD to solve the problems seen in the field. na.prysmiangroup.com/oil-gas adapters stopping plugs reducers breather drain plugs Prysmian s BiCon, (formally BICC), accessories group has developed a gland that allows for simple termination of LV AIRGUARD cable while grounding the sheath for both VFD applications and personal protection. GLANDS ACCESSORIES multi-pin Connector

71 AIA aluminum interlocked armor XHHW Jacket, With Ground Rated for installation in cable trays, duct banks, direct burial, troughs, continuous rigid cable supports, and concrete encaseable. CSA approved is a general designation that describes a type of outer protective armor Any cable configuration or construction that has aluminum interlocked armor will carry this designation Copper based CSA approved armored cable for industrial and commercial medium voltage applications Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # With Ground Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW Green XHHW ARMORED WIRE AND 71

72 AIA aluminum interlocked armor XHHW Jacket, Bare Copper Rated for installation in cable trays, duct banks, direct burial, troughs, continuous rigid cable supports, and concrete encaseable. CSA approved is a general designation that describes a type of outer protective armor Any cable configuration or construction that has aluminum interlocked armor will carry this designation Copper based CSA approved armored cable for industrial and commercial medium voltage applications ARMORED Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # Bare Copper 1/ Bare XHHW / Bare XHHW / Bare XHHW / Bare XHHW / Bare XHHW / Bare XHHW / Bare XHHW / Bare XHHW Bare XHHW Bare XHHW Bare XHHW Bare XHHW /0 Bare XHHW Bare XHHW Bare XHHW /0 Bare XHHW Bare XHHW Bare XHHW Bare XHHW Bare XHHW Bare XHHW Bare XHHW Bare XHHW Bare XHHW Bare XHHW /0 Bare XHHW /0 Bare XHHW BORDER STATES

73 AIA aluminum interlocked armor THHN Jacket, 600 V, With Ground Rated for installation in cable trays, duct banks, direct burial, troughs, continuous rigid cable supports, and concrete encaseable. CSA approved is a general designation that describes a type of outer protective armor Any cable configuration or construction that has aluminum interlocked armor will carry this designation Copper based CSA approved armored cable for industrial and commercial medium voltage applications Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # With Ground Green THHN Green THHN Green THHN Green THHN XHHW Jacket, 5 kv, With Ground Rated for installation in cable trays, duct banks, direct burial, troughs, continuous rigid cable supports, and concrete encaseable. CSA approved is a general designation that describes a type of outer protective armor Any cable configuration or construction that has aluminum interlocked armor will carry this designation Copper based CSA approved armored cable for industrial and commercial medium voltage applications Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # With Ground kv 6 Green XHHW kv 4 Green XHHW /0 3 5 kv 3 Green XHHW /0 3 5 kv 3 Green XHHW kv 1/0 Green XHHW kv 1/0 Green XHHW ARMORED WIRE AND 73

74 AIA CAT 5E aluminum interlocked armor, cat 5e Paired Conductors Suitable for Ethernet 1000 Base-T, PoE (power over Ethernet), ATM 55/155 Mbps, ISDN, digital video, multimedia, voice, and RS422 applications. Accepts and is compatible with all standard RJ45 connectors. The outer covering is aluminum interlocked armor (AIA) Without ground Copper based UL Subject 444 UL/NEC Type CMR or Type CMP as indicated Constructed and Color-Coded to TIA/ANSI standards ETL Certified to TIA 568-C.2 Category 5e Standards (Electrical Testing Certifications) UL Listed to the applicable NEC requirements for each type (Flame Test Listings) ANSI/TIA/EIA 862 (Building Automation) ICEA S ISO/IEC Ed. 2.0 (Class E) Gauge # of Conductors Voltage Jacket BSE Part # Without Ground 24 4Pair 300 PVC ARMORED 74 BORDER STATES

75 MC-HL metal-clad hazardous location Bare Tinned Copper, Paired Conductors For installation in accordance with NEC articles 330, 501, 502 and 505. Consists of two or more conductors and one or more grounding conductors inside an overall corrugated gas/vapor tight continuous corrugated metallic sheath. Rated for up to 35 kv and certified in sizes 18 AWG 2000 kcmil for copper, 12 AWG 2000 kcmil for aluminum, or copper-clad aluminum A non-metallic jacket is installed over the metallic sheath Copper based UL 1569, UL 2250, UL 1277, UL 2225 IEEE 383 ICEA T Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # 18 1Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP Pair Tinned Copper XLP ARMORED WIRE AND 75

76 MC-HL metal-clad hazardous location Bare Tinned Copper, Triad Conductors For installation in accordance with NEC articles 330, 501, 502 and 505. Consists of two or more conductors and one or more grounding conductors inside an overall corrugated gas/vapor tight continuous corrugated metallic sheath. Rated for up to 35 kv and certified in sizes 18 AWG 2000 kcmil for copper, 12 AWG 2000 kcmil for aluminum, or copper-clad aluminum A non-metallic jacket is installed over the metallic sheath Copper based UL 1569, UL 2250, UL 1277, UL 2225 IEEE 383 ICEA T Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # 16 1Triad Tinned Copper XLP Triad Tinned Copper XLP Triad Tinned Copper XLP Bare Tinned Copper, Paired Conductors For installation in accordance with NEC articles 330, 501, 502 and 505. Consists of two or more conductors and one or more grounding conductors inside an overall corrugated gas/vapor tight continuous corrugated metallic sheath. Rated for up to 35 kv and certified in sizes 18 AWG 2000 kcmil for copper, 12 AWG 2000 kcmil for aluminum, or copper-clad aluminum A non-metallic jacket is installed over the metallic sheath Copper based UL 1569, UL 2250, UL 1277, UL 2225 IEEE 383 ICEA T ARMORED Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # 16 2Pair Tinned Copper XLP Pair Tinned Copper XLP BORDER STATES

77 MC-HL metal-clad hazardous location With Ground For installation in accordance with NEC articles 330, 501, 502 and 505. Consists of two or more conductors and one or more grounding conductors inside an overall corrugated gas/vapor tight continuous corrugated metallic sheath. Rated for up to 35 kv and certified in sizes 18 AWG 2000 kcmil for copper, 12 AWG 2000 kcmil for aluminum, or copper-clad aluminum A non-metallic jacket is installed over the metallic sheath Copper based UL 1569, UL 2250, UL 1277, UL 2225 IEEE 383 ICEA T Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP Green XLP / Green XLP / Green XLP / Green XLP Green XLP Green XLP Green XLP ARMORED WIRE AND 77

78 MC-HL metal-clad hazardous location Bare Copper For installation in accordance with NEC articles 330, 501, 502 and 505. Consists of two or more conductors and one or more grounding conductors inside an overall corrugated gas/vapor tight continuous corrugated metallic sheath. Rated for up to 35 kv and certified in sizes 18 AWG 2000 kcmil for copper, 12 AWG 2000 kcmil for aluminum, or copper-clad aluminum A non-metallic jacket is installed over the metallic sheath Copper based UL 1569, UL 2250, UL 1277, UL 2225 IEEE 383 ICEA T ARMORED Gauge # of Conductors Voltage Ground Size Ground Color Jacket BSE Part # Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP / Bare XLP / Bare XLP / Bare XLP / Bare XLP / Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP Bare XLP BORDER STATES

79 MC-HL MOD BUS metal-clad hazardous location mod bus Tinned Copper A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. Used in exposed or concealed wiring in dry or wet conditions, ventilated, non-ventilated or ladder-type cable trays in dry or wet conditions, extreme environments requiring additional protection, on walls or beams. Tinned copper based Directly buried, Class I and II, Div. 2; and Class III, Div. 1 and 2 hazardous locations Gauge # of Conductors Voltage Jacket BSE Part # 18 1Pair 600 XLPE Pair 600 XLPE Experience the savings and advantages of our job site inventory management solutions at your next job site or project location. Call the Border States location nearest you! ARMORED WIRE AND 79

80 LV AIRGUARD COPPER CL 1, DIV 1 low voltage Unshielded Without Ground Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL 2225 TC-ER-HL Class 1 Div. 1 Hazardous Locations UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No C to -35 C Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Jacket Black XHHW XHHW XHHW XHHW XHHW XHHW XHHW XHHW XHHW ARMORED 80 BORDER STATES

81 LV AIRGUARD COPPER CL 1, DIV 1 low voltage Single Pair Overall Shield (SPOS) Without Ground Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL 2225 TC-ER-HL Class 1 Div. 1 Hazardous Locations UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No ºC to -35ºC Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Jacket Black 16 1Pair 600 XLPE Pair 600 XLPE Pair 600 XLPE Triad 600 XLPE ARMORED WIRE AND 81

82 LV AIRGUARD COPPER CL 1, DIV 1 low voltage Unshielded Bare Copper Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL 2225 TC-ER-HL Class 1 Div. 1 Hazardous Locations UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No ºC to -35ºC Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Jacket Black Copper 18 Bare XHHW Copper 14 Bare XHHW Copper 16 Bare XHHW Copper 12 Bare XHHW Copper 14 Bare XHHW Copper 10 Bare XHHW Copper 14 Bare XHHW Copper 12 Bare XHHW ARMORED 82 BORDER STATES

83 LV AIRGUARD COPPER CL 1, DIV 1 low voltage Overall Shield (OS) Bare Copper Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL 2225 TC-ER-HL Class 1 Div. 1 Hazardous Locations UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No ºC to -35ºC Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Jacket Black With Ground Copper 18 Bare XHHW Copper 16 Bare XHHW Copper 14 Bare XHHW Copper 14 Bare XHHW Copper 12 Bare XHHW ARMORED WIRE AND 83

84 LV AIRGUARD COPPER CL 1, DIV 2 low voltage Unshielded Without Ground Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No ºC to -35ºC Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Jacket Black XHHW XHHW XHHW XHHW XHHW / XHHW XHHW XHHW XHHW XHHW ARMORED 84 BORDER STATES

85 LV AIRGUARD COPPER CL 1, DIV 2 low voltage Single Pair Overall Shield (SPOS) Without Ground Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No ºC to -35ºC Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Jacket Black 16 8Pair 600 XLPE Pair 600 XLPE Pair 600 XLPE Pair 600 XLPE ARMORED WIRE AND 85

86 LV AIRGUARD COPPER CL 1, DIV 2 low voltage Unshielded Bare Copper Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No ºC to -35ºC Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Jacket Black Copper 12 Bare XHHW Copper 10 Bare XHHW / Copper 10 Bare XHHW / Copper 10 Bare XHHW ARMORED 86 BORDER STATES

87 LV AIRGUARD COPPER CL 1, DIV 2 low voltage Overall Shield (OS) Bare Copper Suitable for use in the harsh environments found in the heavy industrial and offshore markets installed in underground, sunlight resistant, and oil resistant locations where condensation and moisture accumulations within the conduit do not exceed 90 C. XLPE insulation XHHW jacket UL 1277 TC-ER Exposed Run Rating UL-44-XHHW-2 multiple conductors, direct buried, sunlight resistant, oil resistant ICEA S Control Cable Rating FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger) CSA 22.2 No ºC to -35ºC Cold Bend/Cold Impact MSHA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Jacket Black Copper 12 Bare XHHW Copper 10 Bare XHHW / Copper 10 Bare XHHW / Copper 10 Bare XHHW ARMORED WIRE AND 87

88 MC-HL MEDIUM VOLT metal-clad hazardous location, medium voltage Bare Copper 2.4 kv A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. Used in exposed or concealed wiring in dry or wet conditions, ventilated, non-ventilated or ladder-type cable trays in dry or wet conditions, extreme environments requiring additional protection, on walls or beams. Copper based Directly buried, Class I and II, Div. 2; and Class III, Div. 1 and 2 hazardous locations Gauge # of Conductors Voltage Ground Ground Size Ground Color Armor Type Insulation Shielding BSE Part # Bare Copper, Unshielded kv Bare Copper 10 Bare Continuous MCHL EPR Unshielded Bare Copper, Unshielded kv Bare Copper 10 Bare Interlocked AIA EPR Unshielded Bare 2/ kv Bare Copper 10 Bare MCHL XLP Bare Copper 5.8 kv A general purpose cable used in the power, pulp and paper, mining, petroleum and chemical industries. Used in exposed or concealed wiring in dry or wet conditions, ventilated, non-ventilated or ladder-type cable trays in dry or wet conditions, extreme environments requiring additional protection, on walls or beams. ARMORED Copper based Directly buried, Class I and II, Div. 2; and Class III, Div. 1 and 2 hazardous locations Gauge # of Conductors Voltage Ground Ground Size Ground Color Type Insulation BSE Part # 2/ KV Bare Copper 8 Bare MCHL XLP BORDER STATES

89 TECK 90 Copper 600 V Can be used for exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry locations. Typical applications are for power, lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for hazardous locations and direct burial. Rated for 1000 V, except when applied as MC cable, which then is a 600 V Aluminum interlocked armor (AIA) with an overall PVC jacket Sunlight resistant Nominal operating temperature range of -40 C 90 C Copper based UL 1569 CSA C22.2, No. 131 Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation BSE Part # Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP ARMORED WIRE AND 89

90 TECK 90 Copper 600 V (continued) Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation BSE Part # Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Copper 1 Bare XLP Managing inventory on the job site can be a challenge. We use our SupplyTrax inventory management system to ensure you have the right inventory, at the right levels throughout your project. ARMORED 90 BORDER STATES

91 TECK 90 Copper 1 kv Can be used for exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry locations. Typical applications are for power, lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for hazardous locations and direct burial. It is normally rated for 1000 V, except when applied as MC cable, which then is a 600 V Has aluminum interlocked armor (AIA) with an overall PVC jacket Sunlight resistant Nominal operating temperature range of -40 C 90 C Copper based UL 1569 CSA C22.2, No. 131 Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation BSE Part # kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP /0 3 1 kv Copper 1 Bare XLP /0 3 1 kv Copper 1 Bare XLP /0 3 1 kv Copper 1 Bare XLP /0 3 1 kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP ARMORED WIRE AND 91

92 TECK 90 Copper 1 kv (continued) Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation BSE Part # 1/0 4 1 kv Copper 1 Bare XLP /0 4 1 kv Copper 1 Bare XLP /0 4 1 kv Copper 1 Bare XLP /0 4 1 kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP kv Copper 1 Bare XLP ARMORED 92 BORDER STATES

93 TECK 90 Copper 5 kv Can be used for exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry locations. Typical applications are for power, lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for hazardous locations and direct burial. It is normally rated for 1000 V, except when applied as MC cable, which then is a 600 V Has aluminum interlocked armor (AIA) with an overall PVC jacket Sunlight resistant Nominal operating temperature range of -40 C 90 C Copper based UL 1569 CSA C22.2, No. 131 Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation BSE Part # Unshielded kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE Shielded kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE /0 3 5 kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE ARMORED WIRE AND 93

94 TECK 90 Copper 15 kv Can be used for exposed or concealed wiring in wet or dry locations. For use in ventilated, non-ventilated and ladder type cable troughs and ventilated flexible cableway in wet or dry locations. Typical applications are for power, lighting and control circuits in: pulp and paper mills, steel mills, food processing plants, commercial centers, mines, generating stations, refineries, industrial plants and chemical plants. Rated for hazardous locations and direct burial. It is normally rated for 1000 V, except when applied as MC cable, which then is a 600 V Has aluminum interlocked armor (AIA) with an overall PVC jacket Sunlight resistant Nominal operating temperature range of -40 C 90 C Copper based UL 1569 CSA C22.2, No. 131 Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation BSE Part # kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE / kv Copper 1 Bare XLPE / kv Copper 1 Bare XLPE / kv Copper 1 Bare XLPE / kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE kv Copper 1 Bare XLPE EASY IDENTIFICATION We stock wire and cable in a wide range of colors, allowing for easy identification and installation. This saves you time and provides extra safety by easily identifying termination by wire color. ARMORED 94 BORDER STATES

95 Industrial CORD In this section Type G Type GGC Type W Type P DLO Welding SOOW SEOOW SJOOW SJEOOW SJEW SJTO Submersible pump WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

96 TYPE G grounding 2 kv 500' REEL Used in industrial and light- to medium-duty mining applications, heavy-duty service as power supply cable, power cable for mobile and portable electrical equipment at a continuous conductor temperature of 90 C. May be used in marina (wet) applications and suitable for use on three-phase AC systems where multiple conductors are needed and grounding is required. Designed for portable and extra-hard usage. Rated for up to 2000 V This cable consists of between 2 and 6 conductors with thermoset insulation Has an oil-resistant thermoset jacket Excellent flexibility, resistance to oils, solvents, ozone, aging, and abrasion Sizes range from #12 AWG 500 mcm Rated for -40 C 90 C dry and 75 C wet locations Copper based UL-1650 FT-5 NFPA-70 (2014) RoHS Compliant Gauge # of Conductors Voltage BSE Part # kv kv kv kv kv /0 4 2 kv /0 4 2 kv /0 4 2 kv /0 4 2 kv kv kv kv INDUSTRIAL CORD 96 BORDER STATES

97 TYPE GGC grounding wire with ground check conductor Copper 500' REEL Used in industrial and light- to medium-duty mining applications, heavy-duty service as power supply cable, power cable for mobile and portable electrical equipment at a continuous conductor temperature of 90 C. May be used in marina (wet) applications and suitable for use on three-phase AC systems where 3 or 4 conductors are needed and grounding is required. Designed for portable and extra-hard usage. Rated for up to 2000 V Consists of 3 to 6 conductors with thermoset insulation Has an oil-resistant thermoset jacket Sizes range from #12 AWG 500 mcm Excellent flexibility, resistance to oils, solvents, ozone, aging, and abrasion Rated for -40 C 90 C dry and 75 C wet locations Copper based UL 1650, UL 1581 NFPA-70 (2014) FT-5 RoHS Compliant Gauge # of Conductors # of Strands Voltage Ground Type Ground Size Ground Color BSE Part # kv Copper 10 Bare kv Copper 10 Bare kv Copper 8 Bare kv Copper 7 Bare kv Copper 6 Bare / kv Copper 5 Bare / kv Copper 4 Bare / kv Copper 3 Bare / kv Copper 2 Bare kv Copper 2 Bare kv Copper 1 Bare kv Copper 2 Bare INDUSTRIAL CORD WIRE AND 97

98 TYPE W portable power 2 kv Suitable for use in industrial and light-to-medium mining applications, heavy-duty service and temporary as power supply cables, motor, battery and generator leads. Also used for mobile and portable electrical equipment. Designed for portable, extra-hard usage. Rated for 2000 V Size range from #12 AWG 1000 mcm Can have up to six conductors in sizes #12 AWG 500 mcm In 501 mcm 1000 mcm sizes it has only one conductor The insulation and outer jacket are made of thermoset material Oil resistant Copper based UL 1650 ASTM - All Applicable Standards NEMA WC-58 MSHA P , LR65300 NFPA-70 (2014) FT-5 ICEA S RoHS Compliant INDUSTRIAL CORD Gauge # of Conductors Voltage BSE Part # kv kv kv kv kv /0 1 2 kv /0 1 2 kv /0 1 2 kv /0 1 2 kv kv kv kv kv kv kv kv kv kv kv /0 3 2 kv /0 3 2 kv /0 3 2 kv /0 3 2 kv kv BORDER STATES

99 TYPE W portable power 2 kv (continued) Gauge # of Conductors Voltage BSE Part # kv kv kv kv /0 4 2 kv /0 4 2 kv /0 4 2 kv /0 4 2 kv kv kv kv kv kv /0 5 2 kv /0 5 2 kv /0 5 2 kv /0 5 2 kv Reel Payoff Save up to 75% when we cut your wire pulls to length, install pulling heads, and parallel your wire. Eliminates the need for jack stands and gives you mobility. Reels are less than 32 inches wide and will fit through most door ways. INDUSTRIAL CORD WIRE AND 99

100 TYPE P drilling rig and marine Unarmored 600 V 500' REEL Used in extreme environments which may include severe cold, high heat, constant vibration, drilling mud, mechanical stress, and salt corrosion. Many different types of cable are available with this commercial product offering; including power, control and instrumentation. These cables are insulated with crosslinked polyolefin and are designed for use in off-shore and land based drilling rigs. Single conductor cable is rated for 2000 V and the muti-conductor version is rated for 600 V or 1000 V, depending on the construction Maximum operating temperature of 125 C and pass the cold bend test at -55 C Jacket is Arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant CPE Tinned copper based UL 1309 (Marine Shipboard Cable) CSA 22.2 No. 245 (Marine Shipboard Cable) IEEE Type P (Recommended practice for Marine Cable) IEEE INDUSTRIAL CORD Gauge # of Conductors # of Strands Voltage BSE Part # / / / / BORDER STATES

101 TYPE P drilling rig and marine Unarmored 600 V (continued) 500' REEL Gauge # of Conductors # of Strands Voltage BSE Part # / / / / / / / / INDUSTRIAL CORD WIRE AND 101

102 TYPE P drilling rig and marine Unarmored 600 V (continued) 500' REEL INDUSTRIAL CORD Gauge # of Conductors # of Strands Voltage BSE Part # / / / / BORDER STATES

103 TYPE P drilling rig and marine Unarmored 600 V (continued) 500' REEL Gauge # of Conductors # of Strands Voltage BSE Part # INDUSTRIAL CORD WIRE AND 103

104 TYPE P drilling rig and marine Unarmored 2 kv 500' REEL Used in extreme environments which may include severe cold, high heat, constant vibration, drilling mud, mechanical stress, and salt corrosion. Many different types of cable are available with this commercial product offering; including power, control and instrumentation. These cables are insulated with crosslinked polyolefin and are designed for use in off-shore and land based drilling rigs. Single conductor cable is rated for 2000 V and the muti-conductor version is rated for 600 V or 1000 V, depending on the construction Maximum operating temperature of 125 C and pass the cold bend test at -55 C Jacket is Arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant CPE Tinned copper based UL 1309 (Marine Shipboard Cable) CSA 22.2 No. 245 (Marine Shipboard Cable) IEEE Type P (Recommended practice for Marine Cable) IEEE INDUSTRIAL CORD Gauge # of Conductors # of Strands Voltage BSE Part # kv kv kv kv kv kv kv kv kv kv kv kv / kv / kv / kv / kv kv kv kv kv kv kv kv kv BORDER STATES

105 TYPE P drilling rig and marine Tinned Copper, XLPO Insulated 500' REEL Used in extreme environments which may include severe cold, high heat, constant vibration, drilling mud, mechanical stress, and salt corrosion. Many different types of cable are available with this commercial product offering; including power, control and instrumentation. These cables are insulated with crosslinked polyolefin and are designed for use in off-shore and land based drilling rigs. Single conductor cable is rated for 2000 V and the muti-conductor version is rated for 600 V or 1000 V, depending on the construction Maximum operating temperature of 125 C and pass the cold bend test at -55 C Jacket is Arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant CPE Tinned copper based UL 1309 (Marine Shipboard Cable) CSA 22.2 No. 245 (Marine Shipboard Cable) IEEE Type P (Recommended practice for Marine Cable) IEEE Gauge # of Conductors Voltage BSE Part # / / / INDUSTRIAL CORD WIRE AND 105

106 TYPE P drilling rig and marine Tinned Copper, XLPO Insulated (continued) 500' REEL INDUSTRIAL CORD Gauge # of Conductors Voltage BSE Part # / / / Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Triad Triad BORDER STATES

107 TYPE P drilling rig and marine XLPO Insulated, XLPE Jacket 500' REEL Used in extreme environments which may include severe cold, high heat, constant vibration, drilling mud, mechanical stress, and salt corrosion. Many different types of cable are available with this commercial product offering; including power, control and instrumentation. These cables are insulated with crosslinked polyolefin and are designed for use in off-shore and land based drilling rigs. Single conductor cable is rated for 2000 V and the muti-conductor version is rated for 600 V or 1000 V, depending on the construction Maximum operating temperature of 125 C and pass the cold bend test at -55 C Jacket is Arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant CPE Tinned copper based UL 1309 (Marine Shipboard Cable) CSA 22.2 No. 245 (Marine Shipboard Cable) IEEE Type P (Recommended practice for Marine Cable) IEEE Gauge # of Conductors Voltage BSE Part # 4/0 1 2 kv kv kv kv kv kv kv INDUSTRIAL CORD WIRE AND 107

108 DLO diesel locomotive cable 2 kv 500' AND S Used to wire diesel locomotives, transit and railroad cars, oil and gas drilling rigs, telecom power supply, storage batteries and various types of earth moving machinery. Also is recommended as a portable cable for drilling rigs, both on and off-shore. Rated for 2000 V Has a very high strand count to offer superior flexibility; the 4/0 AWG size has 532 strands of tinned #24 AWG wire It is suited for use in wet or dry areas, conduits, ducts, troughs or trays The outer insulation is EPDM with a paper or polyester tape separating the conductor from the insulation The outer jacket is, typically, black CPE. This cable is CT rated Maximum operating temperature of 90 C in dry and 75 C in wet locations Tinned copper based UL 44 MSHA P CSA C22.2, No. 38 FT-4 VW-1 RoHS-2 Compliant 500' REEL Gauge Voltage BSE Part # 10 2 kv /0 2 kv kv kv kv kv kv kv kv kv INDUSTRIAL CORD Gauge Voltage BSE Part # 14 2 kv kv kv kv kv kv kv /0 2 kv /0 2 kv /0 2 kv kv BORDER STATES

109 WELDING 600 V 250' REEL Used for connecting welding electrodes to welding machines. Has annealed rope-stranded bare copper for superior flexibility and is oil resistant The insulation is EPDM with a paper tape separating it from the conductor Available in sizes #6 AWG 500 mcm The maximum current rating depends on its size The temperature range C Copper based ASTM B-3, ASTM B-172 ICEA S RoHS Compliant Gauge # of Conductors Voltage Black Green Red / / / / INDUSTRIAL CORD WIRE AND 109

110 SOOW service, oil resistant insulation and jacket, weather and water resistant 600 V 250' COIL Typical applications include industrial equipment, heavy tools, battery chargers, portable lights, marine dockside power and mining applications. Designed for extra-hard usage. It is certified for indoor and outdoor use. Designed with two or more conductors for use as specified by NFPA-70 (2014), article 400 Operating temperature of -40 C 90 C Copper based UL 62 Federal Specification J-C-580B MSHA P07-KA MSHA CSA 22.2, No. 49 FT-2 NFPA-70 (2014), Article 400 ICEA S , Color Code Method 1, Table E-1 RoHS Compliant INDUSTRIAL CORD Gauge # of Conductors Voltage Color BSE Part # Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black BORDER STATES

111 SOOW service, oil resistant insulation and jacket, weather and water resistant 600 V (continued) 250' COIL Gauge # of Conductors Voltage Color BSE Part # Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black INDUSTRIAL CORD WIRE AND 111

112 SOOW service, oil resistant insulation and jacket, weather and water resistant 600 V (continued) 250' COIL Gauge # of Conductors Voltage Color BSE Part # Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow INDUSTRIAL CORD 112 BORDER STATES

113 SEOOW service, thermoplastic elastomer, oil resistant insulation and jacket, weather and water resistant 600 V 250' REEL Permitted for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors, and temporary electrical power and lighting installations for construction sites. Suitable for use in (i) dry locations not to exceed minimum -50 C or maximum 105 C; or (ii) wet locations or other applicable locations - may be completely immersed in water - when exposed to oil or coolant at temperatures not to exceed 60 C. Extra-hard usage service cord rated for 600 V It has two or more conductors that are TPE insulated Typically, it comes with a black TPE jacket Conductors are cabled together with paper and polypropylene fillers Heat, moisture and oil resistant Operating temperature range of C Copper based UL 62 Federal Specification J-C-580B MSHA P CSA 22.2 No. 49 NEC Article 400, RoHS Compliant Gauge # of Conductors Voltage Black INDUSTRIAL CORD WIRE AND 113

114 SEOOW service, thermoplastic elastomer, oil resistant insulation and jacket, weather and water resistant 600 V (continued) 250' COIL INDUSTRIAL CORD Gauge # of Conductors Voltage Black BORDER STATES

115 SJOOW service, junior, oil resistant insulation and jacket, weather and water resistant 300 V 250' REEL Used with portable tools, portable appliances, equipment, small motors and light machinery. It s scope of use is specified in NFPA-70, article 400. An indoor and outdoor 300 V rated cord. Has wax paper fillers and a tissue paper separator wrapped around the assembly Available in sizes #18 AWG #10 AWG Is oil and water resistant and has high flexiblity Temperature range of C Copper based UL 62 Federal Specification J-C-580B MSHA PO7-KA MSHA CSA 22.2 No. 49 NFPA-70, Article 400 RoHS Compliant Gauge # of Conductors Voltage Black INDUSTRIAL CORD WIRE AND 115

116 SJEOOW service, junior, thermoplastic elastomer, oil resistant insulation and jacket, weather and water resistant 300 V 250' REEL Used for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors, and temporary electrical power and lighting installations for construction sites. Suitable for use in (i) dry locations not to exceed minimum -50 C or maximum 105 C; or (ii) wet locations or other applicable locations - may be completely immersed in water - when exposed to oil or coolant at temperatures not to exceed 60 C. Rated for 300 V as a hard-usage service cord Available in sizes from #18 AWG #10 AWG The conductors are cabled with polypropylene fillers and they have an overall tissue layer between the conductors and the outer jacket The TPE jacket is heat, moisture and oil resistant Copper based UL 62 Federal Specification J-C-580B MSHA P MSHA CSA 22.2 No. 49 NEC Article 400 RoHS Compliant Gauge # of Conductors Voltage Black INDUSTRIAL CORD 116 BORDER STATES

117 SJEW service, junior, thermoplastic elastomer, weather and water resistant 300 V 250' REEL It is permitted for special uses requiring flexibility and mechanical toughness, high environmental resistance and it is flame retardant. It can also be used for push button remote controls, motor controls, stage equipment and lighting, industrial controls and robotic systems. Outdoor applications are common and it is suitable and approved for submersion in water. Use is permitted in both damp and wet locations. Rated for 300 V The jacket material is TPE Contains polypropylene fillers to maintain a round shape Operating temperature range of C Copper based UL 62, UL 1581 Federal Specification JC-580B CSA C22.2 No. 49 NEC Article 400 RoHS Compliant Gauge # of Conductors Voltage Black INDUSTRIAL CORD WIRE AND 117

118 SJTO service, junior, thermoplastic, oil resistant outer jacket 300 V 250' SPOOL Designed for use with heavy tools, equipment, portable lights, and power extensions. Rated for 300 V The outer jacket is also PVC and are normally offered in gray or yellow Oil, acid, water, alkali and ozone resistant Operating temperature range of C Copper based UL 62 Federal Specification JC-580B ASTM B-174 CSA 22.2 No. 49 NEC Article SPOOLS AT 250' EACH Gauge # of Conductors Voltage Gray Yellow ' SPOOL Gauge # of Conductors Voltage Gray Yellow Maximize time, money and safety Installing a pulling head in the field wastes time and money. We can install it for you so your wire is ready to pull as soon as it s delivered. INDUSTRIAL CORD 118 BORDER STATES

119 SUBMERSIBLE PUMP 600 V 500' AND S A 600 V rated cable used for wiring submersible pumps as specified in the 2014 National Electrical Code. Conductors are covered with a PVC insulation that offers extra protection from mechanical abrasion, and oil and grease resistant Can be jacketed or loose, and it normally consists of four conductors which can be twisted or manufactured as flat cable Jacketing, if specified, is PVC Conductor operating temperature range of C, *the unjacketed version can withstand up to 75 C Copper based UL 493, UL 83 (Jacketed Cable), UL 1581 (Jacketed Cable) CSA C22.2 No. 75; LL90458 Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation 500' Reel 1000' Reel Round Without Ground PVC PVC PVC PVC PVC Twisted With Ground Copper 14 Green PVC Copper 14 Green PVC Copper 12 Green PVC Copper 12 Green PVC Copper 10 Green PVC Copper 10 Green PVC Copper 8 Green PVC Copper 8 Green PVC Round With Ground Copper 12 Green PVC Copper 10 Green PVC Copper 10 Green PVC Copper 8 Green PVC Copper 8 Green PVC Copper 6 Green PVC Flat With Ground Copper 12 Green PVC Copper 12 Green PVC Copper 10 Green PVC Copper 10 Green PVC Copper 10 Green PVC Copper 10 Green PVC Copper 8 Green PVC INDUSTRIAL CORD WIRE AND 119

120 SUBMERSIBLE PUMP 600 V (continued) 500' AND S Gauge # of Conductors Voltage Ground Ground Size Ground Color Insulation 500' Reel 1000' Reel Hard Drawn Flat With Ground Copper 18 Green PVC Copper 14 Green PVC Copper 14 Green PVC Copper 12 Green PVC Copper 12 Green PVC Copper 10 Green PVC Copper 10 Green PVC Copper 10 Green PVC Copper 8 Green PVC Copper 8 Green PVC Copper 6 Green PVC / Copper 6 Green PVC / Copper 6 Green PVC / Copper 4 Green PVC / Copper 4 Green PVC Copper 4 Green PVC Copper 3 Green PVC Copper 2 Green PVC INDUSTRIAL CORD 120 BORDER STATES

121 In this section CM SECURITY CMR CMP T-stat Fire alarm and signal WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

122 CM multi-conductor Solid Unshielded Used in underground ducts, security systems, intercom and PA Systems, sound and audio systems, and power limited controls. For indoor use. CM cable is not rated as riser cable. For general purpose communications use and is resistant to the spread of fire. Conductors are tinned, stranded copper with PVC insulation and rated for 300 V Maximum operating temperature of 105 C Copper based CEC Rating: CM FT1 Gauge # of Conductors Gray White Yellow Orange Green Blue Beige A-Frames. Save time without the need of a wire jack to pull. SECURITY 122 BORDER STATES

123 CM multi-conductor Stranded Use in underground ducts, security systems, intercom and PA Systems, sound and audio systems, and power limited controls. For indoor use. CM cable is not rated as riser cable. For general purpose communications use and is resistant to the spread of fire. Conductors are tinned, stranded copper with PVC insulation and rated for 300 V Can be shielded or unshielded Maximum operating temperature of 105 C Copper based CEC Rating: CM FT1 NEC Article: 800 (Communication Circuits) Gauge # of Conductors Gray White Unshielded Overall Shielded (OAS) SECURITY WIRE AND 123

124 CMR multi-conductor riser Stranded Used for power limited circuits and as communication cable in plenum applications; remote control, signaling, security systems, communications, intercom/pa systems, sound/audio, and nurse call. Suitable for use in a vertical run as riser cable. Has fire-resistant characteristics capable of preventing the carrying of fire from floor to floor. Conductors are stranded or solid bare copper, insulated with PVC and rated for 300 V Thermal operating range is -20 C 75 C Normally shielded and has an overall jacket of PVC Copper based CEC Rating: CMG FT4 NEC (NFPA-70, 2014) Article: 800 SECURITY Gauge # of Conductors Gray Unshielded Overall Shielded (OAS) BORDER STATES

125 CMP multi-conductor plenum Stranded Used as power limited circuit and communication cable in plenums, ducts, and other spaces used for environmental air. It is fire resistant and has low smoke producing properties. Common applications include remote control, signaling, security systems, communications, intercom/pa systems, sound/audio, and nurse call. Consists of shielded or unshielded conductors with PVC insulation rated for 300 V Maximum operating temperature of 75 C Copper based UL Type CMP/CL3P, UL Type CMP/FT6 NEC (NFPA-70, 2014) Article: 800 Gauge # of Conductors Beige White Natural Unshielded Overall Shielded (OAS) Pair Pair Pair SECURITY WIRE AND 125

126 T-STAT thermostat Solid Unshielded 250' REEL A class 2 power-limited cable used in wiring of thermostat controls, heating and air conditioning equipment, doorbells, and other low-voltage applications. Normally has between two and ten conductors that are PVC insulated and rated for 300 V Has an overall PVC jacket Copper based UL 13, UL 1581 NFPA-70, 2014; Article 725 RoHS Compliant Gauge # of Conductors White Brown SECURITY 126 BORDER STATES

127 FIRE ALARM AND SIGNAL Solid Designed as power limited fire alarm and communications cable for riser or non-riser applications. Some applications are smoke detectors, signaling, and fire protective circuits. It is permitted for use in dry or damp locations. Consists of between two and twelve conductors with PVC insulation Has an overall PVC jacket Maximum operating temperature of 105 C Normally available colors are brown and red Copper based CSA C22.2, No. 208, CSA LL90458 File Listing LL68731 FT-4 RoHS Compliant Gauge # of Conductors BSE Part # FPL Solid, Unshielded FPL Solid, Overall Shielded (OAS) FPLP Solid, Unshielded FPLP Solid, Overall Shielded (OAS) SECURITY WIRE AND 127

128 SECURITY 128 BORDER STATES

129 In this section VFD BELDEN Thermocouple Hook-up Classic multi-conductor Classic paired conductor Classic portable cordage Classic industrial cable WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

130

131 VFD variable frequency drive Classic Foil/Braid OAS (Overall Shield) 100' 6000' REELS Carry power from AC drive systems to AC motors. Four-conductor cable (3 circuit, 1 ground and drain wire) Full-size insulated ground Foil & braid shield 90 C wet/dry, sunlight and oil resistant 1000 V UL Flexible Motor Supply Cable 600 V UL TC-ER 1000 V CSA AWM I/II A/B FT4 UL Direct Burial IEEE 1202/383 MSHA* P-07-KA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Put-Up Belden Root Part # Black Tinned Copper 16 Green/Yellow 100' Reel Tinned Copper 16 Green/Yellow 250' Reel Tinned Copper 16 Green/Yellow 500' Reel Tinned Copper 16 Green/Yellow 1000' Reel Tinned Copper 16 Green/Yellow 6000' Reel Tinned Copper 14 Green/Yellow 100' Reel Tinned Copper 14 Green/Yellow 250' Reel Tinned Copper 14 Green/Yellow 500' Reel Tinned Copper 14 Green/Yellow 1000' Reel Tinned Copper 14 Green/Yellow 5000' Reel Tinned Copper 12 Green/Yellow 100' Reel Tinned Copper 12 Green/Yellow 250' Reel Tinned Copper 12 Green/Yellow 500' Reel Tinned Copper 12 Green/Yellow 1000' Reel Tinned Copper 12 Green/Yellow 5000' Reel Tinned Copper 10 Green/Yellow 100' Reel Tinned Copper 10 Green/Yellow 250' Reel Tinned Copper 10 Green/Yellow 500' Reel Tinned Copper 10 Green/Yellow 1000' Reel Tinned Copper 10 Green/Yellow 5000' Reel Tinned Copper 8 Green/Yellow 250' Reel Tinned Copper 8 Green/Yellow 500' Reel Tinned Copper 8 Green/Yellow 1000' Reel Tinned Copper 8 Green/Yellow 3000' Reel Tinned Copper 8 Green/Yellow 5000' Reel Tinned Copper 6 Green/Yellow 250' Reel Tinned Copper 6 Green/Yellow 1000' Reel Tinned Copper 6 Green/Yellow 3500' Reel Tinned Copper 4 Green/Yellow 250' Reel Tinned Copper 4 Green/Yellow 1000' Reel Tinned Copper 4 Green/Yellow 3000' Reel Tinned Copper 2 Green/Yellow 250' Reel Tinned Copper 2 Green/Yellow 500' Reel Tinned Copper 2 Green/Yellow 1000' Reel Tinned Copper 2 Green/Yellow 2000' Reel BELDEN WIRE AND 131

132 VFD variable frequency drive Classic Symmetrical Design OAS (Overall Shield) 250' 3000' REELS Carry power from AC drive systems to AC motors. Three-conductor cable (3 circuit & 3 ground) Dual spiral copper tape shield 90 C wet/dry, sunlight and oil resistant 600 V UL 1277 Type TC-ER UL Direct Burial IEEE 1202/383 MSHA* P-07-KA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Put-Up Belden Root Part # Black kv Bare Copper 1 Green/Yellow 250' Reel kv Bare Copper 1 Green/Yellow 500' Reel kv Bare Copper 1 Green/Yellow 1000' Reel kv Bare Copper 1 Green/Yellow 3000' Reel /0 3 1 kv Bare Copper 1/0 Green/Yellow 250' Reel /0 3 1 kv Bare Copper 1/0 Green/Yellow 500' Reel /0 3 1 kv Bare Copper 1/0 Green/Yellow 1000' Reel /0 3 1 kv Bare Copper 1/0 Green/Yellow 2000' Reel /0 3 1 kv Bare Copper 2/0 Green/Yellow 250' Reel /0 3 1 kv Bare Copper 2/0 Green/Yellow 500' Reel /0 3 1 kv Bare Copper 2/0 Green/Yellow 1000' Reel /0 3 1 kv Bare Copper 2/0 Green/Yellow 2000' Reel /0 3 1 kv Bare Copper 3/0 Green/Yellow 250' Reel /0 3 1 kv Bare Copper 3/0 Green/Yellow 500' Reel /0 3 1 kv Bare Copper 3/0 Green/Yellow 1000' Reel /0 3 1 kv Bare Copper 3/0 Green/Yellow 2000' Reel /0 3 1 kv Bare Copper 4/0 Green/Yellow 250' Reel /0 3 1 kv Bare Copper 4/0 Green/Yellow 250' Reel BELDEN 132 BORDER STATES

133 VFD variable frequency drive Classic Foil/Braid Design OAS (Overall Shield) Signal Pair 100' 5000' REELS Carry power from AC drive systems to AC motors. Four conductor cable (3 circuit, 1 ground and drain wire) Full size insulated ground 16 AWG stranded (26x30) shielded signal pair Foil & braid shield 90 C wet/dry, sunlight and oil resistant 1000 V UL Flexible Motor Supply Cable 600 V UL TC-ER UL Direct Burial 1000 V CSA AWM I/II A/B FT4 IEEE 1202/383 MSHA* P-07-KA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Put-Up Belden Root Part # Black kv Tinned Copper 16 Green/Yellow 100' Reel kv Tinned Copper 16 Green/Yellow 500' Reel kv Tinned Copper 16 Green/Yellow 1000' Reel kv Tinned Copper 16 Green/Yellow 5000' Reel kv Tinned Copper 14 Green/Yellow 100' Reel kv Tinned Copper 14 Green/Yellow 500' Reel kv Tinned Copper 14 Green/Yellow 1000' Reel kv Tinned Copper 14 Green/Yellow 5000' Reel kv Tinned Copper 12 Green/Yellow 100' Reel kv Tinned Copper 12 Green/Yellow 500' Reel kv Tinned Copper 12 Green/Yellow 1000' Reel kv Tinned Copper 12 Green/Yellow 4000' Reel kv Tinned Copper 10 Green/Yellow 100' Reel kv Tinned Copper 10 Green/Yellow 500' Reel kv Tinned Copper 10 Green/Yellow 1000' Reel kv Tinned Copper 10 Green/Yellow 3000' Reel BELDEN WIRE AND 133

134 VFD variable frequency drive Classic Foil/Braid Design Shield, 2 kv 1000' 5000' REELS Carry power from AC drive systems to AC motors. Four conductor cable (3 circuits, 1 ground and drain wire) Full size insulated ground Foil & braid shield 90 C wet/dry, sunlight and oil resistant 2000 V UL Flexible Motor Supply Cable 2000 V UL TC-ER UL Direct Burial 1000 V CSA AWM I/II A/B FT4 IEEE 1202/3837 MSHA* P-07-KA Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Put-Up Belden Root Part # Black kv Tinned Copper 14 Green/Yellow 1000' Reel kv Tinned Copper 14 Green/Yellow 5000' Reel kv Tinned Copper 12 Green/Yellow 1000' Reel kv Tinned Copper 12 Green/Yellow 5000' Reel kv Tinned Copper 10 Green/Yellow 1000' Reel kv Tinned Copper 10 Green/Yellow 5000' Reel kv Tinned Copper 6 Green/Yellow 1000' Reel kv Tinned Copper 6 Green/Yellow 3500' Reel kv Tinned Copper 4 Green/Yellow 1000' Reel kv Tinned Copper 4 Green/Yellow 3000' Reel kv Tinned Copper 2 Green/Yellow 1000' Reel kv Tinned Copper 2 Green/Yellow 2000' Reel Classic Symmetrical Design OAS (Overall Shield), 2 kv 1000' 2000' REELS Carry power from AC drive systems to AC motors. Three conductor cable (3 circuits & 3 ground) Dual spiral copper tape shield 90 C wet/dry, sunlight and oil resistant 2000 V UL Flexible Motor Supply Cable 2000 V UL TC-ER 1000 V CSA AWM I/II A/B FT4 IEEE 1202/383 MSHA* P-07-KA BELDEN Gauge # of Conductors Voltage Ground Type Ground Size Ground Color Put-Up Belden Root Part # Black 1/0 3 2 kv Bare Copper 1/0 Green/Yellow 1000' Reel /0 3 2 kv Bare Copper 1/0 Green/Yellow 2000' Reel /0 3 2 kv Bare Copper 2/0 Green/Yellow 1000' Reel /0 3 2 kv Bare Copper 2/0 Green/Yellow 2000' Reel /0 3 2 kv Bare Copper 3/0 Green/Yellow 2000' Reel /0 3 2 kv Bare Copper 4/0 Green/Yellow 1500' Reel BORDER STATES

135 THERMOCOUPLE Extension, Overall Beldfoil Shield, 20 AWG Solid Conductors Used to create the sensing device and used to carry the signal from the thermocouple to the measuring device. Is flame retardant, resistant to chemicals, and excellent in high temperature applications. Sunlight resistant Oil resistant 105 NEC: CMG CEC: CMG FT4 IEEE 1202/383 ICEA T Gauge # of Conductors Type Black Yellow Brown Belden Root Part # 20 1Pair JX A 20 1Pair KX A 20 1Pair TX A Extension, Overall Beldfoil Shield, 16 AWG Solid Conductors Used to create the sensing device and used to carry the signal from the thermocouple to the measuring device. Is flame retardant, resistant to chemicals, and excellent in high temperature applications. Sunlight resistant Oil resistant 105 NEC: CMG CEC: CMG FT4 IEEE 1202/383 ICEA T Gauge # of Conductors Type Black Yellow Brown Belden Root Part # 16 1Pair JX A 16 1Pair KX A 16 1Pair EX A 16 1Pair TX A BELDEN WIRE AND 135

136 THERMOCOUPLE High-Temperature Extension, 20 AWG Solid Conductors Used to create the sensing device and used to carry the signal from the thermocouple to the measuring device. Is flame retardant, resistant to chemicals, and excellent in high temperature applications. Unshielded FEP insulation and jacket Sunlight resistant Oil resistant 200 UL PLTC NEC CL3P Gauge # of Conductors Type Black Yellow Brown Belden Root Part # 20 2 KX-FEP High-Temperature Extension, 20 AWG Stranded Conductors Used to create the sensing device and used to carry the signal from the thermocouple to the measuring device. Is flame retardant, resistant to chemicals, and excellent in high temperature applications. Unshielded FEP insulation and jacket Sunlight resistant Oil resistant 200 UL PLTC NEC CL3P Gauge # of Conductors Type Black Yellow Brown Belden Root Part # 20 2 JX-FEP BELDEN 136 BORDER STATES

137 THERMOCOUPLE High-Temperature Extension, Overall Beldfoil Shield, 20 AWG Stranded Paired Conductors Used to create the sensing device and used to carry the signal from the thermocouple to the measuring device. Is flame retardant, resistant to chemicals, and excellent in high temperature applications. FEP insulation and jacket Sunlight resistant Oil resistant 200 UL PLTC NEC CL3P Gauge # of Conductors Type Black Yellow Brown Belden Root Part # 20 1Pair JX-FEP Pair KX-FEP Pair TX-FEP High-Temperature Extension, Overall Beldfoil Shield, 16 AWG Stranded Paired Conductors Used to create the sensing device and used to carry the signal from the thermocouple to the measuring device. Is flame retardant, resistant to chemicals, and excellent in high temperature applications. FEP insulation and jacket Sunlight resistant Oil resistant 200 UL PLTC NEC CL3P Gauge # of Conductors Type Black Yellow Brown Belden Root Part # 16 1Pair JX-FEP Pair KX-FEP BELDEN WIRE AND 137

138 THERMOCOUPLE High-Temperature Extension, 20 AWG Solid Conductors Used to create the sensing device and used to carry the signal from the thermocouple to the measuring device. Is flame retardant, resistant to chemicals, and excellent in high temperature applications. Unshielded FEP insulation and jacket Sunlight resistant Oil resistant 200 UL PLTC NEC CL3P Gauge # of Conductors Type Black Yellow Brown Belden Root Part # 20 2 E J T BELDEN 138 BORDER STATES

139 HOOK-UP 300 V, 80 C Solid, UL 1061 Solid conductors suitable for wire wrap applications. Semi-rigid PVC insulation Tinned copper conductor UL 1061 CSA AWM Gauge Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1061 PVC Red Tinned Copper UL 1061 PVC Orange Tinned Copper UL 1061 PVC Yellow Tinned Copper UL 1061 PVC Green Tinned Copper UL 1061 PVC Purple Tinned Copper UL 1061 PVC White Tinned Copper UL 1061 PVC Black Tinned Copper UL 1061 PVC Blue Tinned Copper UL 1061 PVC Red Tinned Copper UL 1061 PVC Orange Tinned Copper UL 1061 PVC Yellow Tinned Copper UL 1061 PVC Green Tinned Copper UL 1061 PVC Gray Tinned Copper UL 1061 PVC White Tinned Copper UL 1061 PVC Black Tinned Copper UL 1061 PVC Brown Tinned Copper UL 1061 PVC Red Tinned Copper UL 1061 PVC Orange Tinned Copper UL 1061 PVC Yellow Tinned Copper UL 1061 PVC Green Tinned Copper UL 1061 PVC Gray Tinned Copper UL 1061 PVC White Tinned Copper UL 1061 PVC Black Tinned Copper UL 1061 PVC Blue Tinned Copper UL 1061 PVC Brown Tinned Copper UL 1061 PVC Red Tinned Copper UL 1061 PVC Orange Tinned Copper UL 1061 PVC Yellow Tinned Copper UL 1061 PVC Green Tinned Copper UL 1061 PVC Purple Tinned Copper UL 1061 PVC Gray Tinned Copper UL 1061 PVC White Tinned Copper UL 1061 PVC Black Tinned Copper UL 1061 PVC Blue Tinned Copper UL 1061 PVC Yellow Tinned Copper UL 1061 PVC Black Tinned Copper BELDEN WIRE AND 139

140 HOOK-UP 300 V, 80 C Stranded, UL 1061 Stranded conductors suitable for wire wrap applications. Semi-rigid PVC insulation Tinned copper conductor UL 1061 CSA AWM BELDEN Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1061 PVC Red Tinned copper UL 1061 PVC Purple Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Brown Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper UL 1061 PVC Green Tinned copper UL 1061 PVC Purple Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Brown Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper UL 1061 PVC Green Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Brown Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper UL 1061 PVC Green Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Brown Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper BORDER STATES

141 HOOK-UP 300 V, 80 C Stranded, UL 1061 (continued) Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1061 PVC Green Tinned copper UL 1061 PVC Purple Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Brown Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper UL 1061 PVC Green Tinned copper UL 1061 PVC Purple Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper UL 1061 PVC Green Tinned copper UL 1061 PVC Purple Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Brown Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper UL 1061 PVC Green Tinned copper UL 1061 PVC Purple Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Brown Tinned copper UL 1061 PVC Red Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Yellow Tinned copper UL 1061 PVC Green Tinned copper UL 1061 PVC Gray Tinned copper UL 1061 PVC White Tinned copper UL 1061 PVC Black Tinned copper UL 1061 PVC Blue Tinned copper UL 1061 PVC Orange Tinned copper UL 1061 PVC Purple Tinned copper BELDEN WIRE AND 141

142 HOOK-UP 300 V, 80 C Stranded, UL 1007 Rated 2500 V peak for electronic circuits, and internal wiring of electronic and electrical equipment. PVC insulation Tinned copper conductor UL 1007 VW-1 Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1007 PVC Brown Tinned Copper UL 1007 PVC Red Tinned Copper UL 1007 PVC Yellow Tinned Copper UL 1007 PVC Green Tinned Copper UL 1007 PVC White Tinned Copper UL 1007 PVC Black Tinned Copper UL 1007 PVC Blue Tinned Copper BELDEN 142 BORDER STATES

143 HOOK-UP 300 V, 80/105 C (UL) V, 90/105 C (CSA) Stranded, Dual-rated 1007 and 1569 Rated 600 V peak for electronic circuits, and internal wiring of electronic and electrical equipment. Dual rated wire PVC insulation Tinned copper conductor UL AWM Style 1007 (except 9989 series) and 1569 CSA Type TR-64-TRSR-64 VW-1 Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # Dual-rated 1007 and 1569 PVC Brown Tinned Copper Dual-rated 1007 and 1569 PVC Red Tinned Copper Dual-rated 1007 and 1569 PVC Orange Tinned Copper Dual-rated 1007 and 1569 PVC Yellow Tinned Copper Dual-rated 1007 and 1569 PVC Green Tinned Copper Dual-rated 1007 and 1569 PVC Gray Tinned Copper Dual-rated 1007 and 1569 PVC White Tinned Copper Dual-rated 1007 and 1569 PVC Black Tinned Copper Dual-rated 1007 and 1569 PVC Blue Tinned Copper Dual-rated 1007 and 1569 PVC Brown Tinned Copper Dual-rated 1007 and 1569 PVC Red Tinned Copper Dual-rated 1007 and 1569 PVC Orange Tinned Copper Dual-rated 1007 and 1569 PVC Yellow Tinned Copper Dual-rated 1007 and 1569 PVC Green Tinned Copper Dual-rated 1007 and 1569 PVC Purple Tinned Copper Dual-rated 1007 and 1569 PVC Gray Tinned Copper Dual-rated 1007 and 1569 PVC White Tinned Copper Dual-rated 1007 and 1569 PVC Black Tinned Copper Dual-rated 1007 and 1569 PVC Blue Tinned Copper Dual-rated 1007 and 1569 PVC Brown Tinned Copper Dual-rated 1007 and 1569 PVC Red Tinned Copper Dual-rated 1007 and 1569 PVC Orange Tinned Copper Dual-rated 1007 and 1569 PVC Yellow Tinned Copper Dual-rated 1007 and 1569 PVC Green Tinned Copper Dual-rated 1007 and 1569 PVC Purple Tinned Copper Dual-rated 1007 and 1569 PVC Gray Tinned Copper Dual-rated 1007 and 1569 PVC White Tinned Copper Dual-rated 1007 and 1569 PVC Black Tinned Copper Dual-rated 1007 and 1569 PVC Blue Tinned Copper Dual-rated 1007 and 1569 PVC Brown Tinned Copper Dual-rated 1007 and 1569 PVC Red Tinned Copper Dual-rated 1007 and 1569 PVC Orange Tinned Copper Dual-rated 1007 and 1569 PVC Yellow Tinned Copper BELDEN WIRE AND 143

144 HOOK-UP 300 V, 80/105 C (UL) V, 90/105 C (CSA) Stranded, Dual-rated 1007 and 1569 (continued) BELDEN Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # Dual-rated 1007 and 1569 PVC Green Tinned Copper Dual-rated 1007 and 1569 PVC Purple Tinned Copper Dual-rated 1007 and 1569 PVC Gray Tinned Copper Dual-rated 1007 and 1569 PVC White Tinned Copper Dual-rated 1007 and 1569 PVC Black Tinned Copper Dual-rated 1007 and 1569 PVC Brown Tinned Copper Dual-rated 1007 and 1569 PVC Red Tinned Copper Dual-rated 1007 and 1569 PVC Orange Tinned Copper Dual-rated 1007 and 1569 PVC Yellow Tinned Copper Dual-rated 1007 and 1569 PVC Green Tinned Copper Dual-rated 1007 and 1569 PVC Purple Tinned Copper Dual-rated 1007 and 1569 PVC Gray Tinned Copper Dual-rated 1007 and 1569 PVC White Tinned Copper Dual-rated 1007 and 1569 PVC Black Tinned Copper Dual-rated 1007 and 1569 PVC Blue Tinned Copper Dual-rated 1007 and 1569 PVC Brown Tinned Copper Dual-rated 1007 and 1569 PVC Red Tinned Copper Dual-rated 1007 and 1569 PVC Orange Tinned Copper Dual-rated 1007 and 1569 PVC Yellow Tinned Copper Dual-rated 1007 and 1569 PVC Green Tinned Copper Dual-rated 1007 and 1569 PVC Purple Tinned Copper Dual-rated 1007 and 1569 PVC Gray Tinned Copper Dual-rated 1007 and 1569 PVC White Tinned Copper Dual-rated 1007 and 1569 PVC Black Tinned Copper Dual-rated 1007 and 1569 PVC Brown Tinned Copper Dual-rated 1007 and 1569 PVC Red Tinned Copper Dual-rated 1007 and 1569 PVC Orange Tinned Copper Dual-rated 1007 and 1569 PVC Yellow Tinned Copper Dual-rated 1007 and 1569 PVC Green Tinned Copper Dual-rated 1007 and 1569 PVC Purple Tinned Copper Dual-rated 1007 and 1569 PVC Gray Tinned Copper Dual-rated 1007 and 1569 PVC White Tinned Copper Dual-rated 1007 and 1569 PVC Black Tinned Copper Dual-rated 1007 and 1569 PVC Blue Tinned Copper Dual-rated 1007 and 1569 PVC Brown Tinned Copper 9989* Dual-rated 1007 and 1569 PVC Red Tinned Copper 9989* Dual-rated 1007 and 1569 PVC Purple Tinned Copper 9989* Dual-rated 1007 and 1569 PVC White Tinned Copper 9989* Dual-rated 1007 and 1569 PVC Black Tinned Copper 9989* Dual-rated 1007 and 1569 PVC Blue Tinned Copper 9989* BORDER STATES

145 HOOK-UP 600 V, 105 C Solid, UL 1015 or 1230 Rated 2500 V peak for electronic circuits, and internal wiring of electronic and electrical equipment. PVC insulation Tinned copper conductor UL 1015 or 1230 UL Type MTW CSA Type TEW VW-1 Gauge Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1015 or 1230 PVC White Tinned Copper UL 1015 or 1230 PVC Blue Tinned Copper BELDEN WIRE AND 145

146 HOOK-UP 600 V, 105 C Stranded, UL 1015 or 1230 Rated 2500 V peak for electronic circuits, and internal wiring of electronic and electrical equipment. PVC insulation, medium wall Flame and ozone resistant Inert to most chemicals, oils, and solvents Tinned copper conductor UL 1015 or 1230 UL Type MTW (except 9924, 8919 and 89214) CSA Type TEW VW-1 BELDEN Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1015 or 1230 PVC Brown Tinned copper UL 1015 or 1230 PVC Red Tinned copper UL 1015 or 1230 PVC Orange Tinned copper UL 1015 or 1230 PVC Yellow Tinned copper UL 1015 or 1230 PVC White Tinned copper UL 1015 or 1230 PVC Black Tinned copper UL 1015 or 1230 PVC Blue Tinned copper UL 1015 or 1230 PVC Brown Tinned copper UL 1015 or 1230 PVC Red Tinned copper UL 1015 or 1230 PVC Orange Tinned copper UL 1015 or 1230 PVC Yellow Tinned copper UL 1015 or 1230 PVC Green Tinned copper UL 1015 or 1230 PVC Purple Tinned copper UL 1015 or 1230 PVC Gray Tinned copper UL 1015 or 1230 PVC White Tinned copper UL 1015 or 1230 PVC Black Tinned copper UL 1015 or 1230 PVC Blue Tinned copper UL 1015 or 1230 PVC Brown Tinned copper UL 1015 or 1230 PVC Red Tinned copper UL 1015 or 1230 PVC Orange Tinned copper UL 1015 or 1230 PVC Yellow Tinned copper UL 1015 or 1230 PVC Green Tinned copper UL 1015 or 1230 PVC Gray Tinned copper UL 1015 or 1230 PVC White Tinned copper UL 1015 or 1230 PVC Black Tinned copper UL 1015 or 1230 PVC Blue Tinned copper UL 1015 or 1230 PVC Brown Tinned copper UL 1015 or 1230 PVC Red Tinned copper UL 1015 or 1230 PVC Orange Tinned copper UL 1015 or 1230 PVC Yellow Tinned copper UL 1015 or 1230 PVC Green Tinned copper UL 1015 or 1230 PVC Purple Tinned copper UL 1015 or 1230 PVC Gray Tinned copper UL 1015 or 1230 PVC White Tinned copper UL 1015 or 1230 PVC Black Tinned copper BORDER STATES

147 HOOK-UP 600 V, 105 C Stranded, UL 1015 or 1230 (continued) Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1015 or 1230 PVC Blue Tinned copper UL 1015 or 1230 PVC Red Tinned copper UL 1015 or 1230 PVC Orange Tinned copper UL 1015 or 1230 PVC Yellow Tinned copper UL 1015 or 1230 PVC Green Tinned copper UL 1015 or 1230 PVC Purple Tinned copper UL 1015 or 1230 PVC Gray Tinned copper UL 1015 or 1230 PVC White Tinned copper UL 1015 or 1230 PVC Black Tinned copper UL 1015 or 1230 PVC Blue Tinned copper UL 1015 or 1230 PVC Brown Tinned copper V, 105 C Stranded, UL 1015, 1283 PVC insulation Tinned copper conductor UL 1015, 1283 Type MTW VW-1 Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 1015, 1283 PVC Brown Tinned Copper UL 1015, 1283 PVC Red Tinned Copper UL 1015, 1283 PVC Green Tinned Copper UL 1015, 1283 PVC Gray Tinned Copper UL 1015, 1283 PVC White Tinned Copper UL 1015, 1283 PVC Black Tinned Copper BELDEN WIRE AND 147

148 HOOK-UP 1000 V, 80 C Solid, UL MIL-W-76C-PVC PVC insulation hook-up wire for internal wiring of electrical and electronic equipment. PVC insulation, medium wall Flame and ozone resistant Inert to most chemicals, oils, and solvents Tinned copper conductor UL MIL-W-76C-PVC Gauge Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # 24 1 kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Blue Tinned Copper kv MIL-W-76C-PVC PVC Purple Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC Blue Tinned Copper BELDEN 148 BORDER STATES

149 HOOK-UP 1000 V, 80 C Stranded, UL MIL-W-76C-PVC PVC insulation hook-up wire for internal wiring of electrical and electronic equipment. PVC insulation, medium wall Flame and ozone resistant Inert to most chemicals, oils, and solvents Tinned copper conductor UL MIL-W-76C-PVC Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # kv MIL-W-76C-PVC PVC Brown Tinned Copper kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Purple Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC White/Black Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC White/Blue Tinned Copper kv MIL-W-76C-PVC PVC White/Brown Tinned Copper kv MIL-W-76C-PVC PVC Brown Tinned Copper kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Purple Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC Brown Tinned Copper kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Purple Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC White/Black Tinned Copper kv MIL-W-76C-PVC PVC White/Green Tinned Copper kv MIL-W-76C-PVC PVC White/Blue Tinned Copper kv MIL-W-76C-PVC PVC White/Gray Tinned Copper kv MIL-W-76C-PVC PVC Brown Tinned Copper BELDEN WIRE AND 149

150 HOOK-UP 1000 V, 80 C Stranded, UL MIL-W-76C-PVC (continued) BELDEN Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Purple Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC Tan Tinned Copper kv MIL-W-76C-PVC PVC Pink Tinned Copper kv MIL-W-76C-PVC PVC White/Black Tinned Copper kv MIL-W-76C-PVC PVC White/Red Tinned Copper kv MIL-W-76C-PVC PVC White/Green Tinned Copper kv MIL-W-76C-PVC PVC White/Blue Tinned Copper kv MIL-W-76C-PVC PVC White/Orange Tinned Copper kv MIL-W-76C-PVC PVC White/Black Tinned Copper kv MIL-W-76C-PVC PVC White/Black Tinned Copper kv MIL-W-76C-PVC PVC Brown Tinned Copper kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Purple Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC Tan Tinned Copper kv MIL-W-76C-PVC PVC White/Black Tinned Copper kv MIL-W-76C-PVC PVC White/Red Tinned Copper kv MIL-W-76C-PVC PVC White/Green Tinned Copper kv MIL-W-76C-PVC PVC White/Yellow Tinned Copper kv MIL-W-76C-PVC PVC White/Blue Tinned Copper kv MIL-W-76C-PVC PVC White/Brown Tinned Copper kv MIL-W-76C-PVC PVC White/Orange Tinned Copper kv MIL-W-76C-PVC PVC White/Gray Tinned Copper kv MIL-W-76C-PVC PVC White/Purple Tinned Copper kv MIL-W-76C-PVC PVC Brown Tinned Copper kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Blue Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper kv MIL-W-76C-PVC PVC White/Black Tinned Copper BORDER STATES

151 HOOK-UP 1000 V, 80 C Stranded, UL MIL-W-76C-PVC (continued) Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # kv MIL-W-76C-PVC PVC Red Tinned Copper kv MIL-W-76C-PVC PVC Orange Tinned Copper kv MIL-W-76C-PVC PVC Yellow Tinned Copper kv MIL-W-76C-PVC PVC Green Tinned Copper kv MIL-W-76C-PVC PVC Blue Tinned Copper kv MIL-W-76C-PVC PVC Gray Tinned Copper kv MIL-W-76C-PVC PVC White Tinned Copper kv MIL-W-76C-PVC PVC Black Tinned Copper V, 105 C Stranded, UL 3192 Recommended maximum baking cycles: F (149 C). CSPE insulation Stranded tinned copper conductor UL 3192 Gauge # of Strands Voltage UL Listing Jacket Color Conductor Belden Root Part # BSE Part # UL 3192 CSPE Black Tinned Copper BELDEN WIRE AND 151

152 CLASSIC MULTI-CONDUCTOR 600 V, 80 C Audio, control and instrumentation cables. Stranded tinned copper conductor C(UL) FT4 VW-1 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper BELDEN 152 BORDER STATES

153 CLASSIC MULTI-CONDUCTOR 300 V, 60 C Audio, control and instrumentation cables. Stranded tinned copper conductor AWM Style NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper BELDEN WIRE AND 153

154 CLASSIC MULTI-CONDUCTOR 150 V, 80 C Audio, control and instrumentation cables. 22 AWG Stranded tinned copper conductor UL AWM Style (Except 8442) NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper Unshielded PVC PVC Chrome Tinned Copper BELDEN 154 BORDER STATES

155 CLASSIC MULTI-CONDUCTOR 300 V, 60 C Foil Shield OAS (Overall Shield) Audio, control and instrumentation cables. Stranded tinned copper conductor AWM Style NEC: CM CEC: CM NEC: CL3 (8618) Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # OAS PO PVC Chrome Tinned Copper OAS PO PVC Chrome Tinned Copper OAS PO PVC Chrome Tinned Copper OAS PE PVC Chrome Tinned Copper V, 75 C Foil Shield OAS (Overall Shield) Audio, control and instrumentation cables. 22 AWG Stranded tinned copper conductor AWM Style NEC: CM, CL3 CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # OAS PE PVC White Tinned Copper BELDEN WIRE AND 155

156 CLASSIC MULTI-CONDUCTOR 300 V, 80 C Foil Shield OAS (Overall Shield) Audio, control and instrumentation cables. 18 AWG Stranded tinned copper conductor AWM Style (except 9770) NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # OAS S-R PVC Chrome Tinned Copper V, 90 C Foil Shield OAS (Overall Shield) Audio, control and instrumentation cables. 22 AWG Stranded tinned copper conductor NEC: CM CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # OAS PP PVC Brown Tinned Copper V, 105 C, 22 AWG Stranded Tinned Copper Braid Shield Audio, control and instrumentation cables. 22 AWG Stranded tinned copper conductor BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Braid Shield PVC PVC Chrome Tinned Copper BORDER STATES

157 CLASSIC MULTI-CONDUCTOR 200 V, 105 C, 20 AWG Stranded Tinned Copper Braid Shield Audio, control and instrumentation cables. 18 AWG Stranded tinned copper conductor AWM Style NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Braid Shield PVC PVC Chrome Tinned Copper Braid Shield PVC PVC Chrome Tinned Copper V, 18 AWG Stranded Tinned Copper Plenum Braid Shield, FEP Jacket Audio, control and instrumentation cables. Suitable for outdoor and direct burial. Non-conduit NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Shielded FEP FEP Red Tinned Copper Shielded FEP FEP Red Tinned Copper V, 18 AWG Stranded Tinned Copper Plenum Braid Shield, Natural Flamarrest Jacket Audio, control and instrumentation cables. Suitable for outdoor and direct burial. Non-conduit NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Shielded FEP LS Natural Tinned Copper BELDEN WIRE AND 157

158 CLASSIC MULTI-CONDUCTOR 300 V Plenum Foil/Braid Shield OAS (Overall Shield) Suitable for outdoor and direct burial applications. Non-conduit C NEC: CMP CEC: CMP FT6 BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper OAS FEP FEP Red Tinned Copper BORDER STATES

159 CLASSIC MULTI-CONDUCTOR 600 V Shielded High-Temperature Control and Instrumentation High temperature control and instrumentation multi-conductor cables C VW-1 MIL-W16878/4 (Type E) Conductors Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Shielded TFE TFE White Silver Plated Copper 83317E Shielded TFE TFE White Silver Plated Copper 83332E Shielded TFE TFE White Silver Plated Copper 83347E Shielded TFE TFE White Silver Plated Copper 83304E Shielded TFE TFE White Silver Plated Copper 83333E Shielded TFE TFE White Silver Plated Copper 83348E Shielded TFE TFE White Silver Plated Copper 83305E Shielded TFE TFE White Silver Plated Copper 83319E Shielded TFE TFE White Silver Plated Copper 83334E Shielded TFE TFE White Silver Plated Copper 83349E Shielded TFE TFE White Silver Plated Copper 83320E Shielded TFE TFE White Silver Plated Copper 83335E Shielded TFE TFE White Silver Plated Copper 83350E Shielded TFE TFE White Silver Plated Copper 83321E Shielded TFE TFE White Silver Plated Copper 83336E Shielded TFE TFE White Silver Plated Copper 83351E Shielded TFE TFE White Silver Plated Copper 83308E Shielded TFE TFE White Silver Plated Copper 83322E Shielded TFE TFE White Silver Plated Copper 83337E Shielded TFE TFE White Silver Plated Copper 83352E BELDEN WIRE AND 159

160 CLASSIC MULTI-CONDUCTOR 300 V, 80 C, 24 AWG Foil Shield Computer cables for RS-232 applications. AWM Style NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper Shielded S-R PVC Chrome Tinned Copper BELDEN 160 BORDER STATES

161 CLASSIC MULTI-CONDUCTOR 300 V, 80 C Low Capacitance Foil/Braid Shield Low-capacitance computer cables for RS-232 applications. AWM Style NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper OAS S-R PVC PVC Chrome Tinned Copper V, 105 C Fire Alarm Power-Limited Fire alarm limited fire protective signaling circuit cables. AWM Style NEC: MPR, FPLR CEC: FAS 105 FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Solid Unshielded PVC PVC Red Bare Copper Solid Unshielded PVC PVC Red Bare Copper BELDEN WIRE AND 161

162 CLASSIC MULTI-CONDUCTOR 600 V, 105 C Braid Shield Audio, control and instrumentation cables. Solid tinned copper conductors VW-1 MIL-W (Type B) Conductors Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper Braid Shield PVC PVC White Tinned Copper BELDEN 162 BORDER STATES

163 CLASSIC PAIRED CONDUCTOR 300 V, 80 C Solid, 19 AWG Audio, control and instrumentation cables. Solid tinned copper conductors NEC: CM CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 19 1Pair 300 Solid Unshielded PVC PVC Chrome Bare Copper Pair 300 Solid Unshielded PVC PVC Chrome Bare Copper V, 80 C Stranded Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMG CEC: CMG FT4 UL AWM Style 2464 (Except 8205) Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 20 1Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper BELDEN WIRE AND 163

164 CLASSIC PAIRED CONDUCTOR 300 V, 80 C Unshielded, Plenum Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2598 (8471) UL AWM Style 2587 (8473 and 8477) NEC: CMP NEC: CMG (8471) NEC: CL3 (8473) NEC: CL3R (8477) CEC: CMP FT6 CEC: CMG FT4 (8471) CEC: FAS 90 FT4 (8473) Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 16 1Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper V, 22 AWG Stranded Unshielded, FEP/FEP, Plenum Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 3Pair Unshielded FEP FEP Red Tinned Copper Pair Unshielded FEP FEP Red Tinned Copper BORDER STATES

165 CLASSIC PAIRED CONDUCTOR 300 V, 22 AWG Stranded Unshielded, FEP/Flamarrest Plenum Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 2Pair Unshielded FEP LS Natural Tinned Copper Pair Unshielded FEP LS Natural Tinned Copper Pair Unshielded FEP LS Natural Tinned Copper Pair Unshielded FEP LS Natural Tinned Copper V Unshielded, Plenum, Red FEP Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 18 1Pair Unshielded FEP FEP Red Tinned Copper BELDEN WIRE AND 165

166 CLASSIC PAIRED CONDUCTOR 300 V Unshielded, Plenum, Red Fluorocopolymer Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 18 1Pair Unshielded FEP PVDF Red Tinned Copper V Unshielded, Plenum, Natural Flamarrest Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 18 1Pair Unshielded FEP LS Natural Tinned Copper BELDEN 166 BORDER STATES

167 CLASSIC PAIRED CONDUCTOR 150 V, 80 C Unshielded, PVC/PVC Telephone Audio, control and instrumentation cables. Solid tinned copper conductors UL AWM Style 2576 NEC: CMG CEC:CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 2Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper Pair 150 Solid Unshielded PVC PVC Chrome Tinned Copper V, 80 C Stranded Unshielded 22 AWG Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2576 NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 2Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper Pair Unshielded PVC PVC Chrome Tinned Copper BELDEN WIRE AND 167

168 CLASSIC PAIRED CONDUCTOR 300 V, 80 C OAS (Overall Shield), 22 AWG Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2464 (300 V, 80 C) NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 1Pair Shielded S-R PVC PVC Beige, Pale Fawn Tinned Copper V, 75 C OAS (Overall Shield), 22 AWG Audio, control and instrumentation cables. Stranded tinned copper conductors Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 1Pair Shielded PVC PVC Chrome Tinned Copper BELDEN 168 BORDER STATES

169 CLASSIC PAIRED CONDUCTOR 300 V, 60 C OAS (Overall Shield), 22 AWG Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2092 (300 V, 60 C) NEC: CM CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 1Pair Shielded PE PVC Chrome Tinned Copper V OAS (Overall Shield), 22 AWG Natural Flamarrest Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 1Pair Shielded FEP LS Natural Tinned Copper V OAS (Overall Shield), 22 AWG Red FEP Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 1Pair Shielded FEP FEP Red Tinned Copper BELDEN WIRE AND 169

170 CLASSIC PAIRED CONDUCTOR 300 V OAS (Overall Shield), 22 AWG Red Fluorocopolymer Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 1Pair Shielded FEP PVDF Red Tinned Copper V, 80 C OAS (Overall Shield), Beige PVC Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2464 (300 V, 80 C) NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 20 1Pair Shielded PVC PVC Beige, Light Tinned Copper V, 60 C OAS (Overall Shield), Chrome PVC Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors UL Style 2092 NEC: CM CEC: CM BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 20 1Pair Shielded PE PVC Chrome Tinned Copper Pair Shielded PE PVC Chrome Tinned Copper BORDER STATES

171 CLASSIC PAIRED CONDUCTOR 300 V, 80 C OAS (Overall Shield), Red FEP Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 18 1Pair Shielded FEP FEP Red Tinned Copper V, 60 C OAS (Overall Shield), Red Fluorocopolymer Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 18 1Pair Shielded FEP PVDF Red Tinned Copper V, 80 C OAS (Overall Shield), Natural Flamarrest Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 18 1Pair Shielded FEP LS Natural Tinned Copper BELDEN WIRE AND 171

172 CLASSIC PAIRED CONDUCTOR 600 V, 80 C OAS (Overall Shield), 16 AWG Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style NEC: CM, CL2 CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 16 1Pair Shielded PE PVC Chrome Tinned Copper V, 80 C OAS (Overall Shield), 14 AWG Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style NEC: CM, CL2 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 14 1Pair Shielded PE PVC Chrome Tinned Copper V, 80 C OAS (Overall Shield), 12 AWG Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style C(UL) AWM II A NEC: CL2 BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 12 1Pair Shielded PE PVC Chrome Tinned Copper BORDER STATES

173 CLASSIC PAIRED CONDUCTOR 300 V, 80 C OAS (Overall Shield) Audio, control and instrumentation cables. Solid tinned copper conductors UL AWM Style 2464 NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 2Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper V, 60 C OAS (Overall Shield) Audio, control and instrumentation cables. Solid tinned copper conductors NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 51Pair 300 Solid Shielded PVC PVC Chrome Tinned Copper BELDEN WIRE AND 173

174 CLASSIC PAIRED CONDUCTOR 300 V, Overall Duofoil Shield Audio, control and instrumentation cables. Solid tinned copper conductors NEC: CM CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 22 2Pair 300 Solid Shielded FPE PVC Black Tinned Copper V, 80 C OAS (Overall Shield), Plenum and Non-Plenum Audio, control and instrumentation cables. Stranded tinned copper conductors NEC: CM CEC: CM AWM Style 2092 BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 1Pair Shielded PE PVC Chrome Tinned Copper BORDER STATES

175 CLASSIC PAIRED CONDUCTOR 300 V, 150 C High-Temperature Overall Beldfoil Shield Audio, control and instrumentation cables. Stranded tinned copper conductors VW-1 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 20 4Pair Shielded ETFE ETFE Clear, Transparent Tinned Copper Pair Shielded ETFE ETFE Clear, Transparent Tinned Copper V, 80 C ISP (Individual Shielded Pair), SR-PVC/PVC, Chrome PVC Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2464 NEC: CMG CEC: CMG FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 20 2Pair ISP S-R PVC Chrome Tinned Copper BELDEN WIRE AND 175

176 CLASSIC PAIRED CONDUCTOR 300 V, 80 C ISP (Individual Shielded Pair), Black High-Density Polyethylene Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2919 NEC: CMG CEC: CMP FT4 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 20 3Pair ISP PP HDPE Black Tinned Copper Pair ISP PP HDPE Black Tinned Copper V, 80 C ISP (Individual Shielded Pair), Polypropylene/PVC, Chrome PVC Jacket Audio, control and instrumentation cables. Stranded tinned copper conductors UL AWM Style 2919 NEC: CM CEC: CM BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 20 3Pair 30 7 ISP PP PVC Chrome Tinned Copper Pair 30 7 ISP PP PVC Chrome Tinned Copper Pair 30 7 ISP PP PVC Chrome Tinned Copper Pair 30 7 ISP PP PVC Chrome Tinned Copper Pair 30 7 ISP PP PVC Chrome Tinned Copper Pair 30 7 ISP PP PVC Chrome Tinned Copper Pair ISP PP PVC Chrome Tinned Copper Pair ISP PP PVC Chrome Tinned Copper Pair ISP PP PVC Chrome Tinned Copper Pair ISP PP PVC Chrome Tinned Copper Pair ISP PP PVC Chrome Tinned Copper BORDER STATES

177 CLASSIC PAIRED CONDUCTOR 400 V, 80 C IOAS (Individual Overall Shielded), Chrome PVC Jacket Special audio, communication and instrumentation cables. Stranded tinned copper conductors Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 25 2Pair IOAS PE PVC Chrome 3 str Tinned Copper + 4 str Tinned Copper Covered Steel Low Capacitance OAS (Overall Shield), 28 AWG Datalene /PVC Low-capacitance computer cables for RS-232 and RS-422 applications. Stranded tinned copper conductors UL AWM Style 2919 NEC: CL2 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 28 2Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 8132FO Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 8134FO Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 8135FO Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 8138FO Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 8142FO BELDEN WIRE AND 177

178 CLASSIC PAIRED CONDUCTOR Low Capacitance OAS (Overall Shield), 24 AWG Polyethylene/PVC Low-capacitance computer cables for RS-232 and RS-422 applications. Stranded tinned copper conductors UL AWM Style 2919 NEC: CM CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 3Pair 30 7 Shielded PE PVC Chrome Tinned Copper Pair 30 7 Shielded PE PVC Chrome Tinned Copper Pair 30 7 Shielded PE PVC Chrome Tinned Copper Pair 30 7 Shielded PE PVC Chrome Tinned Copper Pair 30 7 Shielded PE PVC Chrome Tinned Copper Low Capacitance OAS (Overall Shield), 24 AWG Datalene /PVC Low-capacitance computer cables for RS-232 and RS-422 applications. Stranded tinned copper conductors UL AWM Style 2919 NEC: CM CEC: CM CEC: FT (1419A, 1420A) BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 2Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 1419A Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 1420A Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 1421A Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 1422A Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 1423A Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 1424A Pair 30 7 Shielded FPE PVC Chrome Tinned Copper 1425A BORDER STATES

179 CLASSIC PAIRED CONDUCTOR ISP (Individual Shielded Pair) RS-422 and Digital Audio Low-capacitance 100 Ohm computer cables for RS-422 and digital audio applications. Stranded tinned copper conductors UL AWM Style 2493 NEC: CM CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 2Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper Pair ISP FPE PVC Chrome Tinned Copper ISP (Individual Shielded Pair) Plenum RS-232, RS-422, and Digital Audio Gray Fluorocopolymer Jacket Low-capacitance 100 Ohm computer cables for RS-422 and digital audio applications. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 2Pair ISP FFEP PVDF Gray Tinned Copper Pair ISP FFEP PVDF Gray Tinned Copper Pair ISP FFEP PVDF Gray Tinned Copper Pair ISP FFEP PVDF Gray Tinned Copper Pair ISP FFEP PVDF Gray Tinned Copper BELDEN WIRE AND 179

180 CLASSIC PAIRED CONDUCTOR ISP (Individual Shielded Pair) RS-232, RS-422, and Digital Audio Natural Flamarrest Jacket Low-capacitance 100 Ohm computer cables for RS-422 and digital audio applications. Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 # of Gauge Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 2Pair ISP FFEP LS Natural Tinned Copper Overall Foil/Braid Shield, Polyethylene/PVC Low-capacitance computer cables for RS-485 applications. RS-485, DMX512 Stranded tinned copper conductors UL AWM Style 2919 NEC: CM CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 1Pair 30 7 Shielded PE PVC Chrome Tinned Copper Pair 30 7 Shielded PE PVC Chrome Tinned Copper Pair 30 7 Shielded PE PVC Chrome Tinned Copper Pair 30 7 Shielded PE PVC Chrome Tinned Copper Plenum Overall Foil/Braid Shield, FEP/Flamarrest Low-capacitance computer cables for RS-485 applications. RS-485 Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 1Pair Shielded FFEP LS Natural Tinned Copper Pair Shielded FFEP LS Natural Tinned Copper BORDER STATES

181 CLASSIC PAIRED CONDUCTOR Plenum Overall Foil/Braid Shield, FEP/FEP Low-capacitance computer cables for RS-485 applications. RS-485 Stranded tinned copper conductors NEC: CMP CEC: CMP FT6 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 1Pair Shielded FFEP FEP Red Tinned Copper Pair Shielded FFEP FEP Red Tinned Copper V, 60 C Individually Shielded Pairs with Overall Foil/Braid Shield Low-capacitance computer cables for RS-232, RS-422, and digital audio applications. Stranded tinned copper conductors UL AWM Style 2493 (60 C) NEC: CM CEC: CM VW-1 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 24 2Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper Pair Shielded FPE PVC Chrome Tinned Copper BELDEN WIRE AND 181

182 CLASSIC PORTABLE CORDAGE 300 V, 60 C Beldfoil Shielding Stranded Multi-Conductor Type SVT Stranded bare copper conductors UL/CSA Listed Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Shielded PVC PVC Black Bare Copper V, 60 C Paper Tape Separator Stranded Multi-Conductor Stranded tinned copper conductors UL AWM Style 4097 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Unshielded EPDM Rubber Black Tinned Copper V, 60 C Paper Tape Separator Stranded Multi-Conductor Type SO Stranded bare copper conductors UL/CSA Listed BELDEN Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Unshielded EPDM Rubber Black Bare Copper Unshielded EPDM Rubber Black Bare Copper BORDER STATES

183 CLASSIC INDUSTRIAL Braid Shield Twinax Industrial automation and process control cables. RG-22B/U Type Stranded bare copper conductors VW-1 Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # 18 1Pair Braid Shield PE PVCNC Black Bare Copper Thicknet 10Base5 Ethernet Coaxial Industrial automation and process control cables. Solid bare copper conductors UL AWM Style 1478 (30 V, 60 C) NEC: CM CL2 CEC: CM Gauge # of Conductors Voltage # of Strands Shielding Insulation Jacket Color Conductor Belden Root Part # BSE Part # Solid Quad Shield FPE PVC Yellow Bare Copper BELDEN WIRE AND 183

184 BELDEN 184 BORDER STATES

185 In this section Overhead secondary UTILITY Underground secondary Underground primary Bare overhead Galvanized steel strand and static Aluminum tie Riser WHAT'S THAT ICON? MORE SIZES CUT TO LENGTH

186 Who says you can t have it all? With more than 170 years of experience behind us, General Cable leads the wire and cable industry in quality and innovation. With leading brands and a vast portfolio of products each representing a solution to market-specific challenges and requirements General Cable is committed to powering our partners growth and success. General Cable High-, Medium- or Low-Voltage Electric Utility Cables for Overhead and Underground (TransPowr, EmPowr, PowrServ ) General Cable Hazardous Location Armored Cables for Power, Control, Automation, Signal and Instrumentation (CCW ) Carol Brand Portable Cord, Industrial Cord & Cordset Products (Super Vu-tron ) Call Border States today for your General Cable electric utility, industrial and commercial cabling needs. Let Border States put its people, products and programs to work for you.

187 OVERHEAD SECONDARY Duplex, Triplex, Triplex Reduced Neutral and Quadruplex MULTIPLE LENGTHS AVAILABLE ACSR-neutral aluminum service drop is available in duplex, triplex and quadruplex configurations for overhead service entrance applications. 600 V Maximum conductor operating temperature of 90 C for cross-linked polyethlyene insulation and 75 C for polyethylene insulated conductors PE or XLP insulation Image courtesy of General Cable Meets or exceeds ASTM specifications Size AWG or kcmil Insulation Neutral Stranding Put-Up Code Name BSE Part # Duplex /1 500' Coil Shepherd /1 3300' Reel Shepherd /1 2400' Reel Terrier Triplex /1 2200' Reel Voluta /1 500' Coil Periwinkle /1 1500' Reel Periwinkle /1 500' Coil Conch /1 1800' Reel Conch / /1 500' Coil Neritina / /1 1200' Reel Neritina / /1 1500' Reel Runcina / /1 1000' Reel Zuzara Triplex Reduced Neutral /1 250' Coil Cockle /1 1800' Reel Cockle / /1 1200' Reel Janthina Quadruplex /1 500' Coil Hackney /1 1700' Reel Hackney /1 500' Coil Palomino /1 1800' Reel Palomino / /1 1200' Reel Costena / /1 1500' Reel Grullo / /1 1100' Reel Appaloosa UTILITY WIRE AND 187

188 UNDERGROUND SECONDARY Three and Four Conductor MULTIPLE LENGTHS AVAILABLE Designed for secondary distribution and underground service at 600 volts or less. Aluminum cable features XLP insulation with a yellow striped neutral or solid yellow neutral. Suitable for direct burial or in duct. 600 V Aluminum conductor Available as single, duplex, triplex and quadruplex Suitable for temperatures of 90 C in wet or dry locations. Copper conductor available upon request Sizes available kcmil Image courtesy of General Cable UL standard 854 for type USE-2 Meets or exceeds all applicable requirements of ICEA S UTILITY Size AWG or kcmil Conductor Insulation Neutral Insulation Put-Up Code Name Type BSE Part # Triplex ' Reel Vassar Solid Yellow Neutral ' Reel Vassar 3 Stripe Neutral ' Reel Stephens Solid Yellow Neutral ' Reel Ramapo Solid Yellow Neutral ' Reel Ramapo 3 Stripe Neutral /0-2-1/ ' Reel Brenau Solid Yellow Neutral /0-1-2/ ' Reel Converse Solid Yellow Neutral /0-2/0-4/ ' Reel Sweetbriar Solid Yellow Neutral /0-2/0-4/ ' Reel Sweetbriar 3 Stripe Neutral /0-4/0-4/ ' Reel Monmouth 3 Stripe Neutral / ' Reel Pratt Solid Yellow Neutral Quadruplex ' Reel Dyke 3 Stripe Neutral ' Reel Dyke 3 Stripe Neutral /0-4/0-4/0-4/ ' Reel Wakeforest 3 Stripe Neutral Series ' Reel Stephens 3 Stripe Neutral /0-2-1/ ' Reel Brenau 3 Stripe Neutral /0-1-2/ ' Reel Converse 3 Stripe Neutral /0-4/0-4/ ' Reel Monmouth 3 Stripe Neutral / ' Reel Pratt 3 Stripe Neutral /0-2/0-4/ ' Reel Sweetbriar 3 Stripe Neutral /0-2/0-4/ ' Reel Sweetbriar 3 Stripe Neutral / ' Reel Wesleyan 3 Stripe Neutral BORDER STATES

189 UNDERGROUND PRIMARY EPR and TRXLP 2500' REEL May be direct buried or installed in ducts. TRXLPE-insulated conductors are rated at 90 C for normal operation and 130 C for emergency. EPR-insulated conductors are rated at 105 C for normal operation and 140 emergency. Filled strand refers to material that when applied, impedes the flow of moisture in stranded conductor. Image courtesy of General Cable kv Aluminum conductor Copper conductor available upon request Other reduced neutral configurations are often used for kcmil size wires, i.e. 1/6, 1/8 etc are available upon request Size AWG or kcmil # of Wires # of Neutral Wires Neutral Size (AWG) Type BSE Part # TRXLP 220 Mil Solid Filled Strand /0 Solid Solid /0 Solid Solid / Filled Strand / Filled Strand Filled Strand TRXLP 260 Mil 1/0 Solid Solid / Filled Strand / Filled Strand / Filled Strand / Filled Strand Filled Strand TRXLP 345 Mil 1/ Filled Strand EPR 220 Mil 2 Solid Solid Filled Strand /0 Solid Solid /0 Solid Solid / Filled Strand / Filled Strand / Filled Strand Filled Strand Filled Strand Filled Strand EPR 260 Mil 1/0 Solid Solid / Filled Strand / Filled Strand Filled Strand EPR 345 Mil 1/ Filled Strand UTILITY WIRE AND 189

190 BARE OVERHEAD ACSR and ACSR Twisted Pair MULTIPLE LENGTHS AVAILABLE ACSR conductors combine the light weight and high conductivity of aluminum with the high tensile strength of steel. The steel core may consist of a single core wire or 7, 19, 37 or more wires, depending on the electrical demand and strength characteristics required by the particular application. Aluminum conductors, steel reinforced are used for overhead distribution lines. ACSR twisted-pair construction is designed for use in overhead applications where the line is subject to wind-induced vibration resulting in galloping due to either wind or ice loading. Class A galvanized core wire is standard, but B and C coatings are available An additional "non specular" surface abrasion can be applied to reduce reflectivity in environmentally sensitive locales Image courtesy of General Cable Size AWG or kcmil Strand Put-Up Code Name Reel Length/FT BSE Part # ACSR 4 7/1 600# Swanate 8,955' /1 885# Sparrow 9,695' /1 600# Sparate 5,625' /0 6/1 885# Raven 6,095' /0 6/1 885# Quail 4,835' /0 6/1 885# Penguin 3,040' /0 6/1 1770# Penguin 6,080' /7 3795# Partridge 10,330' /7 3795# Linnet 8,195' /1 2075# Merlin 5,696' ACSR Twisted Pair 2 6/1 1765# Sparrow 9,695' /0 6/1 1770# Raven 6,095' /0 6/1 1770# Penguin 6,080' /7 3790# Partridge 10,330' /7 4235# Linnet 9,160' UTILITY 190 BORDER STATES

191 GALVANIZED STEEL STRAND AND STATIC Galvanized Class A MULTIPLE LENGTHS AVAILABLE Designed for use as overhead ground wires or static wires for electric power transmission lines (ASTM A363) or for guy strand, messenger cable and span wires (ASTM A 475). Additional grades available: Siemens Martin (SM), High Strength (HS), Extra High Strength(EHS) and Utility Grade (UG) Additional zinc coating available (Class A, Class B, Class C) Image courtesy of National Strand Meets or exceeds ASTM Specifications A475 and A363 Meets or exceeds REA Specifications Strand Diameter ASTM Put-Up BSE Part # SM 3/8 A ' Coil /8 A ' Coil /16 A ' Coil /4 A ' Coil EHS 5/16 A ' Coil /8 A ' Coil /16 A ' Coil /2 A ' Coil /8 A ' Reel /2 A ' Reel /16 A ' Coil /16 A ' Coil /4 A ' Coil HS 3/8 A ' Coil /16 A ' Coil /8 A ' Coil /16 A ' Coil /4 A ' Coil /4 A ' Coil UG 3/8 A ' Coil /16 A ' Coil /16 A ' Coil UTILITY WIRE AND 191

192 ALUMINUM TIE Solid Aluminum Bare MULTIPLE LENGTHS AVAILABLE Generally used in overhead line constructions to mechanically secure conductors to pin insulators. Bare aluminum EC grade solid conductor Solid, soft annealed aluminum conductor ASTM B-230 aluminum 1350-H19 wire for electrical purposes Size (AWG) Put-Up Reel Length/Feet BSE Part # 6 25#/Box 1,033' #/Box 413' #/Reel 1,033' #/Box 654' #/Reel 654' RISER Copper Solid and Stranded MULTIPLE LENGTHS AVAILABLE Used as uninsulated transformer risers at voltages up to 35 kv line to line. Conductors are solid or stranded soft copper Stranded conductors are concentrically stranded, compressed Covering is high molecular weight polyethylene, black Larger sizes available upon request ASTM B3: soft or annealed copper wire ASTM B8: concentric-lay-stranded copper conductors, hard, medium-hard, or soft ANSI/ICEA: S UTILITY Size (AWG) Put-Up BSE Part # Solid 6 500' Coil ' Coil ' Coil ' Reel Stranded ' Reel ' Coil ' Reel ' Coil ' Coil BORDER STATES

193 In this section Index Belden INDEX

194 194 BORDER STATES It s easy to find PRODUCTS Belden Root # BELDEN INDEX A A A A A A A A A A A A A A FO FO FO FO FO E E E E E E E E E E E E E E E E E E E E Wire and

195 In this section Glossary and abbreviations GLOSSARY and abbreviations

196 GLOSSARY AND ABBREVIATIONS A amp or ampere AC alternating current An electrical current that frequently reverses direction. AC resistance Total resistance offered by a device in an alternating current circuit due to inductive and capacitive effects as well as the direct current resistance. ACSR aluminum conductor steel-reinforced AEIC Association of Edison Illuminating Companies AIA aluminum interlocked armor A type of cable sheath. Alloy A metal formed by combining two or more metals to obtain desirable properties. ANSI American National Standards Institute A private nonprofit organization that oversees the development of voluntary consensus standards for products, services, processes, systems and personnel in the United States. ASTM American Society for Testing and Materials An international standards organization that develops and publishes voluntary consensus technical standards for a wide range of materials, products, systems and services. ASME American Society of Mechanical Engineers A professional association that promotes the art, science and practice of multidisciplinary engineering and allied sciences around the globe via continuing education, training and professional development, codes and standards, research, conferences and publications, government relations, and other forms of outreach. AWG American Wire Gauge A standardized wire gauge system used predominantly in the United States and Canada for the diameters of round, solid, nonferrous, electrically conducting wire. Amp/Ampere The SI unit of electric current. Ampacity The maximum current an insulated wire or cable. Anode The electrode through which a direct current enters the liquid, gas or other discrete part of an electrical circuit; the positively charged pole of an electrochemical cell. Approved Per the OSHA definition, a product that has been tested to standards and found suitable for general application, subject to limitations outlined in the nationally recognized testing lab s listing. Armor A braid or wrapping of metal, usually steel, placed over the outer sheath for mechanical protection. Armored Cable Cable having a metallic covering for protection against mechanical injury. ARRA American Recovery and Reinvestment Act AWM appliance wiring material A recognized component used in UL-listed or classified products. Bare Conductor Has no coating or cladding on the copper. Bend Radius Denotes the minimum radius that an insulated cable may be safely bent during installation and use. Blown Jacket Outer cable covering applied by controlled inflation of the cured jacket tube and then pulling the cable through it. Braid A fibrous or metallic group of filaments interwoven in cylindrical form covering one or more wires. BSC bare soft copper Uncoated annealed copper. Building Wire Wire used for light and power, 600 V or less. Bunch Strand Any number of conductor strands twisted together in one direction and containing the same lay length. Buried Cable A cable installed directly in the earth without use of an underground conduit. Bus Wire Used to connect two terminals inside an electrical unit. Buy American Compliant The Buy American Act restricts the purchase of supplies that are not domestic end products for use within the United States. Cable A group of individually insulated conductors in twisted or parallel configuration with or without an overall covering. Cable Assembly A completed cable and its associated hardware ready for install. Cable Filler The material used in multiple conductor cables to occupy the spaces formed by the assembly of components, thus forming a core of the desired shape. Cable Jacket/Sheath The material applied outermost to a wire or cable to provide mechanical and environmental protection. Cable Tray A unit or assembly of units or sections, and associated fittings, made of noncombustible materials forming a rigid structural system used to support cables. Cabling The twisting together of two or more insulated conductors to form a cable. Cabling Factor Used in the formula for calculating the diameter of an unshielded, unjacketed cable. D=Kd, where D is the cable diameter, K is the factor and d is the diameter of one insulated conductor. Caged Armor A construction using wires within a jacket to increase mechanical protection and tensile strength. Capacitance Storage of electrically separated charges between two plates that have different potentials. Capacitance (Unbalance to Ground) An inequality of capacitance between the ground capacitance of the conductors of a pair that results in a pickup of external source of energy, usually from power transmission lines. Capacitance (Unbalance) An inequality of capacitance between the wires of two or more pairs that results in a transfer of unwanted signal from one pair to others. Capacitive Coupling Electrical interaction between two conductors caused by the capacitance between them. Capacitive Reactance The opposition to alternating current due to the capacitance of a cable, circuit or capacitor. Capacitor Two conducting surfaces separated by a dielectric material. The capacitance is determined by the area of the surface, types of dielectric, and spacing between the conducting surfaces. Cathodic Protection The control of the electrolytic corrosion of an underground or underwater metallic structure by the application of an electric current through a sacrificial anode in such a way that the structure is made to act as a cathode of an electrolytic cell. Chlorinated Polyurethane CPE Widely used as a thermoplastic elastomer (TPE), rubber and modifier for resins (PVC, PE and ABS) because of its excellent resistance properties against heat, oil, chemical, fire and weather. Chlorosulfonated Polyethylene CSPE Synthetic rubber, otherwise known Hypalon, is noted for its resistance to chemicals, temperature extremes, and ultraviolet light. Circuit The complete path through which a current flows or part of the complete path, such as one conductor. Cladding A method of applying a layer of metal over another metal whereby the junction of the two metals is continuously welded. CM communications rated Used in cases where fire code does not restrict cable type. CMA circular mil area A unit of area that is equal to the area of a circle with a diameter of one mil. CMR communications riser Prevents fire spreading from floor to floor, designed for use in risers and vertical shafts. Coating A material applied to the surface of a conductor to prevent environmental deterioration, facilitate soldering or improve electrical performance. 196 BORDER STATES

197 Coaxial Cable A cable consisting of two cylindrical conductors with a common axis, separated by a dielectric. CoilPAK Easily stackable wire for storage and pulling. Color Code A system for circuit identification through use of solid colors and contrasting tracers. Compatibility The ability of dissimilar materials to exist in mutual proximity or contact without changing their physical or electrical properties. Composite Cable A cable consisting of two or more different types or sizes of wires. Compound An insulating or jacketing material made by mixing two or more ingredients. Compressed A conventional conductor manufactured to a diameter not more than 3 percent below the nominal diameter of a noncompressed conductor of the same cross-sectional area. Compressed Stranded Conductor A conventional concentric conductor manufactured to a diameter not more than 3 percent below the nominal diameter of a noncompressed conductor of the same cross-sectional area. Concentric Lay Cable A multiple conductor cable composed of a central core surrounded by one or more layers of helically laid insulated conductors. Concentric Strand A group of uninsulated wires twisted so as to contain a center core with one or more distinct layers of spirally wrapped, uninsulated wires laid overall to form a single conductor. Concentric Stranding A central wire surrounded by one or more layers of helically wound strands in a fixed round geometric arrangement. Conductivity The capability of a material to carry electrical current, usually expressed as a percentage of copper conductivity. Conductor An uninsulated wire suitable for carrying electrical current. Conductor Core The center strand or member about which one or more layers of wires or members are laid helically to form a concentric-lay or rope-lay conductor. Conduit A tube or trough in which insulated wires and cables are run. Connector A device used to physically and electrically connect two or more conductors. Contact The part of a connector that carries the electrical current. Continuity Check A test to determine whether electrical current flows continuously throughout the length of a single wire or individual wires in a cable. Control Cable A multiconductor cable made for operation in control or signal circuits. Copper A chemical element with the symbol Cu and atomic number 29. It is a ductile metal with very high thermal and electrical conductivity. Copper-Clad Steel CCS Also known as copper-covered steel or the trademarked name Copperweld, is a bi-metallic product mainly used in the wire industry that combines the high mechanical resistance of steel with the conductivity and resistance to corrosion of copper. Cord A small, flexible insulated cable. CPE Chlorinated Polyethylene Widely used as a thermoplastic elastomer (TPE), rubber and modifier for resins (PVC, PE and ABS) because of its excellent resistance properties against heat, oil, chemical, fire and weather. Cross-Linked Inter-molecular bonds between long chain thermoplastic polymers by chemical or electron bombardment means. CSA Canadian Standards Association The Canadian counterpart of the Underwriters Laboratories. CSPE chlorosulfonated polyethylene synthetic rubber Otherwise known as Hypalon, CSPE is noted for its resistance to chemicals, temperature extremes, and ultraviolet light. CT cable tray frame rating Current The rate of flow of electricity in a circuit, measured in amperes. Current Carrying Capacity Or ampacity, is the maximum current an insulated wire or cable can safely carry without exceeding either the insulation or jacket material limitations. Current Rating The maximum continuous electrical flow of a current recommended for a given wire situation. DC direct current A type of electric current that flows in only one direction. Direct Burial Cable A cable installed directly in the earth without use of an underground conduit. Direct Capacitance The capacitance measured directly from conductor to conductor through a single insulating layer. Direct Current Resistance The resistance offered by any circuit to the flow of direct current. Direction of Lay The lateral direction in which a conductor or group of conductors of a cable run over the top of the cable as the elements recede from the observer looking along the axis of the cable. DLO diesel locomotive Double Shield Combination shield usually consisting of alum/ mylar and a woven braid shield. Drain Wire In a cable, the uninsulated wire in intimate contact with a shield to provide for easier termination of such a shield to a ground point. Drum-Packed The method of coiling wire into fiber drums for shipment. Duct An underground or overhead tube for carrying electrical conductors. Duplex Insulated In the thermocouple industry, a combination of dissimilar metal conductor of a thermocouple or thermocouple extension wire. Elastomer A rubber-like substance. EMT electrical metallic tubing EPR ethylene propylene rubber An ozone resistant rubber consisting primarily of ethylene propylene copolymer (EPM) or ethylene propylene diene terpolymer (EPDM). ETFE ethylene tetrafluoroethylene Otherwise known as Teflon. ETL Edison Testing Laboratories FAA Federal Aeronautics Administration Fatigue Resistance Resistance to metal crystallization that leads to conductors or wires breaking from flexing. FEP fluorinated ethylene propylene A Teflon fluorocarbon resin that is registered TM of the DuPont Company. Fiber A thread or threadlike structure. Also, a single discrete element used to transmitoptical information. Fiber Dispersion Pulse spreading in a fiber caused by differing transit times of various modes. Fiber Optics A lightwave or optical communications system in which electrical information is converted to light energy, transmitted to another location through optical fibers, and is there converted back into electrical information. Field Area through which passes electric and/or magnetic lines of force. Flame Resistance The ability of a material to prevent the spread of combustion by a low rate of travel so the flame will not be conveyed. Flammability The measure of the material's ability to support combustion. Flammability Test A test to determine the ability of a cable to resist ignition when placed near a source of heat or flame and to self-extinguish when removed from this source. Flat Braid A woven braid of tinned copper strands rolled flat at time of manufacture to a specified width. Flat Cable A cable with two smooth or corrugated flat surfaces. Flat Conductor A wire having a rectangular cross section as opposed to round or square conductors. GLOSSARY AND ABBREVIATIONS WIRE AND 197

198 GLOSSARY AND ABBREVIATIONS Flat Conductor Cable A cable with a plurality of flat conductors. Flex Life The measurement of the ability of a conductor or cable to withstand repeated bending. Flexibility The ease with which a cable may be bent. FR-1 A flammability rating established by Underwriters Laboratories for wires and cables that pass a specially designed vertical flame test. This designation has been replaced by VW-1. Frequency Number of times an alternating current reverses itself in one second. FT-2 Minimum mandatory horizontal flame test for flexible cord (finished cable). FT-4 Test used on cables intended for tray or shaft applications. Gauge A term used to denote the physical size of a wire. G Rubber-insulated, neoprene, Hypalon or CPE jacketed, portable power cable with two to five #8 AWG or larger conductors with ground wires. GGC A portable power cable similar to type G but also having a ground check conductor. Ground A conducting connection between an electrical circuit and the earth or other large conducting body to serve as an earth, thus making a complete electrical circuit. Grounded Conductor A system of circuit conductor that is intentionally grounded. Grounded Neutral Neutral wire that is mechanically connected to ground. Grounding Conductor A conductor used to connect equipment or the grounded circuit of a wiring system to a grounding electrode of electrodes. Hard Drawn Copper Wire Copper wire that has not been annealed after drawing. Hermetically Sealed A gaslight enclosure that has been completely sealed by fusion or other comparable means. High Voltage Generally a wire or cable with an operating voltage of over 35,000 V. Hook-Up Wire A single insulated conductor used for low current, low voltage (usually under 600 V) applications within enclosed electronic equipment. Hot Tin Dip A process of passing bare wire through a bath of molten tin to provide a coating. Hypalon DuPont s trade name for their chlorosulfonated polyethylene, an ozone resistant synthetic rubber. IACS International Annealed Copper Standard IAEI International Association of Electrical Inspectors ICEA Insulated Cable Engineers Association (formerly IPCEA) IEC International Electrotechnical Commission Similar to the ISO in structure and scope. IECA S Standard for nonshielded power cables rated 2000 V or less for the distribution of electrical energy covers THHN/THWN, XHHW and RHH/RHW/USE cables. IEEE Institute of Electrical and Electronics Engineers IMC intermediate metal conduit Impedance The total opposition that a circuit offers to the flow of alternating current or any other varying current at a particular frequency. IMSA International Municipal Signal Association Specifications for fire alarm cable. Insulation A material having high resistance to the flow of electric current. Insulation Resistance Property of an insulating material that resists electrical current flow through the insulating material when a potential difference is applied. Insulation Thickness The wall thickness of the applied insulation. Interference Any undesired electrical signal induced into a conductor by electrical or electromagnetic means. IPCEA International Power Cable Engineering Association IR insulation resistance Resistance offered by an insulation to an impressed DC voltage, tending to produce a leakage current through the insulation. ISA Instrument Society of America ISO International Standards Organization Jacket An outer covering, usually nonmetallic, mainly used for protection against the environment. Jackets Cover and protect enclosed wires or core against damage, chemical attack, fire and other harmful elements that may be present in the operating environment. Jumper Cable A short, flat cable interconnecting two wiring boards or devices. K Constant used to denote insulation resistance. KCM 1,000 circular mils Kilowatt A term denoting 1,000 watts. kv kilovolt 1000 V kva kilovolt ampere KW kilowatt KWH kilowatt hours 1,000 watt hours Laminated Tape A tape consisting of two or more layers of different materials bonded together. LANCE local area network for controller Ethernet LANS local area networks system Integration of computer and communication. Lay The axial distance required for one cabled conductor or conductor strand to complete one revolution about the axis around which it is cabled. Lay Direction The twist in the cable as indicated by the top strands while looking along the axis of the cable away from the observer. Described as right hand or left hand. Leadwire Single conductor wire. Longitudinal Shield A tape shield, applied longitudinally with the axis of the core being shielded. Longitudinal Wrap Tape applied longitudinally with the axis of the core being shielded. LS low smoke Lug A termination, with provision for screwing down to a terminal. MC metal-clad cable NEC type designation for power and control cables enclosed in a smooth metallic sheath, welded and corrugated metallic sheath, or an interlocking tape armour. MCM 1,000 circular mils MFT 1,000 feet Mil A unit used in measured diameter of a wire or thickness of insulation over a conductor. Moisture Absorption The amount of moisture, in percentage, that a material will absorb under specified conditions. Moisture Resistance The ability of a material to resist absorbing moisture from the air or when immersed in water. Monomer The basic chemical unit used in building a polymer. MPF mine power feeder cable MSHA Mine Safety and Health Administration U.S. Department of Labor established standards and safety requirements for mines. MTW Thermoplastic-insulated machine tool wire C, 600 V. Multi-Conductor More than one conductor within a single cable. MW Radio hookup wire with polyvinyl insulation and plain or nylon jacket, braid or shield, 1000 V. 198 BORDER STATES

199 Mylar DuPont trademark for a polyester material used in the form of a tape. NBFU National Bureau of Fire Underwriters NBS National Bureau of Standards NEC A consensus standard published by the National Fire Protection Association (NFPA) and incorporated in OSHA regulations. NEMA National Electrical Manufacturers Association Neoprene Polychloroprene, a thermosetting compound. NFPA National Fire Protection Association NM Non-metallic sheathed cable, braid or plastic covered, for dry use, 60 C. NM-B Non-metallic sheathed cable Plastic covered, for dry use, 90 C. NMC Non-metallic sheathed cable Plastic or neoprene covered. Wet or dry use, 60 C, and corrosive applications. Noise Unwanted and/or unintelligible signals picked up on a cable circuit. Nominal O.D. The desired diameter for a cable that is established within a +/- tolerance. Nylon A group of polyamide polymers used for wire and cable jacketings. OD outer diameter OEM original equipment manufacturer Off-Center Conductor individual shielded pairlaced within the cross section of its insulation. Offgassing Percentage of a specified gas released during the combustion of insulation or jacketing material. OFHC oxygen-free high-conductivity copper Oil Aging Cable aged in an accelerated manner by placement in an oil bath and heated to a pre-set temperature for a stated time. Oil-Filled Cable A self-contained pressure cable in which the pressure medium is low viscosity oil having access to the insulation. Opaque Not permitting the passage of light. OSHA Occupational Safety and Health Act Administered by U.S. Dept. of Labor, which establishes standards and safety requirements which all businesses must meet. Outgassing The dissipation of gas from a dielectric evidencing decomposition. Overall Diameter Finished diameter over wire and cable. Overcoat Individual strands of tin copper stranded together and covered with a tin coating. Overcoated Copper composed of tinned copper strands twisted together followed by an overall tin coating. Overcurrent The current that causes an excessive temperature rise in a conductor. Overlap The amount the trailing edge laps over the leading edge of a tape wrap. Oxygen Index Percentage of oxygen necessary to support combustion of a specified material. Ozone A highly active form of oxygen produced by the passage of electric discharges or sparks through air or oxygen. P 110 C temperature rating, IEEE 1580 Type P. Packing Fraction The ratio of active cross-sectional area of fiber core or cores to the total end surface of the fiber or fiber bundle. Pair Two insulated wires of a single circuit associated together. Pairing The union of two insulated single conductors through twisting. Parallel Cable Two insulated conductors side-by-side in a cable. Plasticizer A chemical agent added to plastics to make them softer and more pliable. Plenum The air return path of a central-air handling system, either ductwork or open space over a dropped ceiling. Plenum Cable Cable approved by Underwriters Laboratories for installation in plenums without the need for conduit. PLTC power limited tray cable For use in class 2 or 3 power-limited circuits; instrumentation supervisory control, and thermocouple extension. Polyester Polyethylene terephthalate, used extensively in the production of a high-strength moistureresistant film used as a cable core wrap. Polyethylene A thermoplastic material having the chemical identity of polymerized ethylene. Polymer A substance made of many repeating chemical units or molecules. Polyolefin A family of thermoplastics based on the unsaturated hydrocarbons known as olefins. Polypropylene A thermoplastic polymer of propylene. Polyurethane Has exceptional resistance to oil, radiation, fungus, oxidation and ozone. Porosity Multiple air voids in an insulation jacket wall. Potting The sealing of a cable termination or other component with a liquid that thermosets into an elastomer. Power Cables Cables of various sizes, construction, and insulation, designed to distribute primary power to various types of equipment. Power Factor The ratio of resistance to impedance. The ratio of the actual power of an alternating current to apparent power. PPE portable power elastomer Pre-Bond Stranded wire that has been fused, topcoat tinned, or overcoat tinned. Prebond Copper Prebond heavy tin-coated individual wires stranded, then bonded by resistance heat. Prefused Copper Otherwise known as prebond copper, is composed of twisted strands of heavy tinned copper fused along its entire length by heating. Primary Insulation The first layer of nonconductive material applied over a conductor whose prime function is to act as electrical insulation. PTFE polytetrafluoroethylene Pulling Eye A device fastened to a cable to which a hook may be attached in order to pull the cable into or from a duct. PullPro Easily stackable wire for storage and pulling. Pulse A current or voltage that changes abruptly from one value to another and back to the original value in a finite length of time. Pulse Cable A type of coaxial cable constructed to transmit repeated high-voltage pulses without degradation. PV photovoltaic wire PVC polyvinyl chloride A thermoplastic material composed of polymers of vinyl chloride that may be rigid or elastomeric. Used for general purpose applications at temperatures up to 105 C. PVD polyvinylidene fluoride (Kynar) Pyrometer A non-contacting device that intercepts and measures thermal radiation, a process known as pyrometry. Quad A four-conductor cable. Rated Temperature The maximum temperature at which an electric component can operate for extended periods without loss of its basic properties. Rated Voltage The maximum voltage at which an electric component can operate for extended periods without undue degradation or safety hazard. REA Rural Electrification Administration REACH Registration, Evaluation, Authorization and Restriction of Chemical substances Reactance The opposition offered to the flow of alternating current by inductance or capacitance of a component or circuit. GLOSSARY AND ABBREVIATIONS WIRE AND 199

200 GLOSSARY AND ABBREVIATIONS Recovered Edge Edge of a flat cable or conductor from which measurements are made. Reference Junction The junction of a thermocouple which is at a known reference temperature. Reflection Loss The part of signal lost due to reflection of power at a line discontinuity. Reflow Soldering The process of connecting two solder-coated conductive surfaces by remelting of the solder to cause fusion. Resin An organic substance of natural or synthetic origin characterized by being polymeric in structure and predominantly amorphous. Resistance In DC circuits, the opposition a material offers to current, measured in ohms. In AC circuits, resistance is the real component of impedance and may be higher than the value measured at DC. Retractile Cable A cable that returns by its own stored energy from an extended condition to its original contracted form. RG/U Radio Government, Universal RG is the military designation for coaxial cable; U stands for general utility. RHH rubber-insulated, heat resistant Building wire, 90 C. RHW rubber-insulated, heat and moisture resistant Building wire, 75 C dry or wet. RHW-2 rubber insulation, heat resistant 90 C, suitable for wet location Ribbon Cable A flat cable of individually insulated conductors lying parallel and held together by means of adhesive or woven textile yarn. RMS root mean square RoHS Restriction of Hazardous Substances Rope Lay Conductor A conductor composed of a central core surrounded by one or more layers of helically laid groups of wire. Rope Strand A conductor composed of a center group of twisted strands surrounded by layers of twisted strands. Rope Stranding Composed of cabled groups of any of the following stranded members: bunched, true concentric, compressed, unidirectional concentric, unilay, equilay. Round Conductor A conductor whose cross section is substantially circular. Rulan DuPont s trade name for their flame-retardant polyethylene insulating material. S Heavy-duty, rubber-insulated portable cord. Stranded copper conductors with separator and individual rubber insulation. Two or more color-coded conductors cabled with filler, wrapped with separator and rubber jacketed overall, 600 V. SAE Society of Automotive Engineers SA-NEC Conductor type designation for conductors with silicone insulation and glass braid (formerly asbestos), for use in dry locations. SBR Rubber co-polymer of styrene and butadiene. SD service drop Two code, rubber insulated conductors, tape, laid parallel with neutral conductor concentric thereover. Tape and braid overall. Also round construction. SDN Small-diameter multi-conductor control cable with neoprene jacket and nylon sheath over polyethylene insulation. SE Above-ground service entrance cable, not protected against mechanical abuse. Flame-retardant, moisture-resistant covering. Overall neoprene sheath, C. Secondary Insulation A high-resistance dielectric material placed over primary insulation to protect from abrasion. Self-Extinguishing The characteristic of a material whose flame is extinguished after the igniting flame is removed. Self-Supporting Aerial Cable A cable consisting of one or more insulated conductors factory-assembled with a messenger that supports the assemblage and which may or may not form a part of the electrical circuit. Self-Supporting Cable Any assemblage of conductors which incorporates a steel rope of steel sheath for added tensile strength, thus enabling it to be suspended between widely spaced supports. Semi-Conducting Tape A tape of such resistance that when applied between two elements of a cable, the adjacent surfaces of the two elements will maintain substantially the same potential. Semiconductor A material that has a resistance characteristic between that of insulators and conductors. Semi-Rigid PVC A hard, semi-flexible polyvinylchloride compound with low plasticizer content. SEOOW/STOW Service cord with Elastomer jacket, oil-resistant jacket, oil-resistant insulation and weather resistant. Same as SEOW but has oil-resistant singles, too. SEOOW meets CSA approval for outdoor use as STOW, 600 V. SEOW/STOW Service cord with Elastomer jacket, oil-resistant jacket and weather-resistant. SEOW meets CSA approval for outdoor use as STOW. Features a Thermoplastic Elastomer (TPE) jacket and insulation and is water resistant, 600 V. Separator A layer of insulating material such as textile, paper, polyester, etc. Used to improve stripping qualities, flexibility, mechanical or electrical protection to the components. SER service round entrance cable Type SE, Style R. SEU service entrance cable Type SE, Style U, unarmored. SEW Silicone rubber insulated equipment wire (CSA). SEWF Silicone rubber insulated equipment wire (CSA). SF Silicone rubber insulated fixture wire, solid or seven strand conductor, 200 C. SFF Same as SF, except flexible stranding, 150 C. Shielded-GC Portable mine power cable, three or four individually shielded conductors, with grounding conductors, 5000 V V V. Sheath The outer covering or jacket of a multiconductor cable. Shield A metallic layer placed around a conductor or group of conductors to prevent electrostatic interference between the enclosed wires and external fields. Shield Coverage The physical area of a cable that is actually covered by the shielding material and is expressed in percent. Shield Effectiveness The relative ability of a shield to screen out undesirable signals. Shield Percentage The physical area of a circuit or cable actually covered by shielding material, expressed in percent. SIC specific inductive capacitance Same as dielectric constant. Signal A current used to convey information. Signal Cable A cable designed to carry current of usually less than one ampere per conductor. Silver Metallic chemical element with the chemical symbol Ag and atomic number 47. SIS Indicates single conductor having synthetic thermosetting insulation of heat-resistant, moisture-resistant, flame-retarding grade. Also made with chemically cross-linked polyethylene insulation. Used for switchboard wiring only, 90 C. SJ Junior hard service, rubber-insulated pendant or portable cord. Same construction as type S, but 300 V jacket thickness different. SJEOOW Junior hard service, thermoplastic elastomer, oil-resistant jacket, insulation and outside jacket. 200 BORDER STATES

201 SJEW Hard service thermoplastic or rubber-insulated conductors and overall Thermoplastic jacket. All elastomer construction. 300 V, 90 C to 105 C, weather-resistant. SJO Same as SJ, but neoprene, oil-resistant compound outer jacket. 300 V, 60 C. SJOOW Same as type SJO, except oil-resistant insulation and oil- and weather- resistant jacket. SJT Junior hard service thermoplastic or rubberinsulated conductors with overall thermoplastic jacket, 300 V, 60 C to 105 C. SJTO Same as SJT but oil-resistant thermoplastic outer jacket, 60 C. SO Hard service cord, same construction as type S except oil-resistant neoprene jacket, 600 V, C. Solid Conductor A single unit not divided into parts. SOOW Service cord with oil-resistant jacket, oil-resistant insulation and weather resistant. Also is water-resistant, 600 V. SOW Water-resistant neoprene jacketed portable cord (UL/CSA). SP-1 All rubber, parallel jacketed, two-conductor light-duty cord for pendant or portable use in damp locations, 300 V. SP-2 Same as SP-1, but heavier construction, 300 V. SP-3 Same as SP-2, but heavier construction for refrigerators or room air conditioners, 300 V. Spark Test A test designed to locate imperfections in the insulation of a wire or cable by application of a voltage for a very short period of time while the wire is being drawn through the electrode field. SPC Submersible pump cable. Spiral Wrap The helical wrap of a material over a core. SP-OS Multiple shielded pairs or triads with overall shield, instrumentation or thermocouple extension cable. SPT-1 Same as SP-1, except all thermoplastic, 300 V. With or without third conductor for grounding. SPT-1.5 Service cord with parallel conductors and thermoplastic insulation. AWM Style 20288, extra flexible parallel cord for use as internal wiring of appliances or can be woven through links of chains, 300 V. SPT-2 Same as SP-2, except all thermoplastic, 300 V. With or without third conductor for grounding. SPT-3 Same as SP-3, except all thermoplastic, 300 V. With or without third conductor for grounding. ST Hard service cord, jacketed, same as type S except all-plastic construction, 600 V, C. Stability Factor The difference between the percentage power factor at 80 volts/mil and at 40 volts/mil measured on wire immersed in water at 75 C for a specified time. STO Same as ST but with oil-resistant thermoplastic outer jacket, 600 V, 60 C. STOO Same as STO but with oil-resistant insulation. STOW Service cord with oil resistant thermoplastic jacket and weather resistant. Meets CSA approval for outdoor use. Can be waterresistant, UL 600. Strand A single uninsulated wire. Stranded Conductor A conductor composed of individual groups of wires twisted together to form an entire unit. Strip To remove insulation or jacket to expose the conductor. STW Service cord with thermoplastic and weather resistant jacket, but not oil resistant. Can be UL water resistant. Meets CSA approval for outdoor use, 600 V. Surlyn DuPont s trade name for their thermoplastic resin with ionic crosslinks. SV Vacuum cleaner cord, two or three conductor, rubber-insulated. Overall rubber jacket. For light duty in damp locations, 300 V, 60 C. SVO Same as SV except neoprene jacket, 300 V, 60 C. SVT Same as SV except all-plastic construction. With or without third conductor for grounding purposes only, 300 V, C. SVTO Same as SV except all-plastic construction. With or without third conductor for grounding purposes only, 300 V, C. Switchboard Cable A cable used within and between the central office main frames and the switchboard. Tape Insulations Used as primary insulation, tape insulations include TFE, Kapton, Mica, Polyester, alone or laminated with other materials, etc. Tape Wrap A spirally applied tape over an insulated or uninsulated wire. TC tinned copper Tear Strength The force required to initiate or continue a tear in a material under specified conditions. Teflon A DuPont trademark for fluorocarbon resins. FEP, PFA and TFE are typical materials. Teflon FEP DuPont trade name, fluorinated ethylene propylene or FEP is a copolymer of hexafluoropropylene and tetrafluoroethylene. Teflon PFA DuPont trade name, polytetrafluoroethylene (PTFE) is a synthetic fluoropolymer of tetrafluoroethylene. Temperature Coefficient of Resistivity The amount of resistance change of a material per degree of temperature rise. Temperature Ratings The maximum temperature at which an insulating material may be used in continuous operation without loss of its basic properties. Tensile Strength The pull stress required to break a given specimen. Tensile Stress A term denoting the greatest longitudinal tensile stress a substance can bear without tearing apart or rupturing. Tension Member A member included in a fiber cable to add tensile strength. Terminals Metal wire termination devices designed to handle one or more conductors and to be attached to a board, bus or block with mechanical fasteners or clipped on. Test Lead A flexible, insulated lead wire used for making tests, connecting instruments to a circuit temporarily, or for making temporary electrical connections. TEW Canadian Standards Association type appliance wires. Solid or stranded single conductor, plastic insulated, 600 V, 105 C. Textile Braid Any braid made from threads of cotton, silk or synthetic fibers. TFFN Fixture wire, thermoplastic-covered solid or seven strands with nylon sheath, 60 C. Thermal Aging Exposure to a thermal condition or programmed series of conditions for predescribed periods of time. Thermal Rating The maximum and/or minimum temperature at which a material will perform its function without undue degradation. Thermal Resistance Change in the electrical resistance of a material when subjected to heat. Resistance to heat flow from conductors to outer surface of insulation or sheath in a wire of cable. Thermal Resistivity Thermal resistance of a unit cube of material. Thermal Shock A test to determine the ability of a material to withstand heat and cold by subjecting it to rapid and wide changes in temperature. Thermocouple A device consisting of two dissimilar metals in physical contact, which when heated will develop an EMF output. GLOSSARY AND ABBREVIATIONS WIRE AND 201

202 GLOSSARY AND ABBREVIATIONS Thermocouple Element A thermocouple designed to be used as part of an assembly but without associated parts such as the terminal block, connecting head or protecting tube. Thermocouple Extension Cable A cable made of one or more twisted thermocouple extension wires under a common sheath. Thermocouple Extension Wire A pair of wires of dissimilar alloys having such EMF-temperature characteristics complementing the thermocouple that is intended to be used, such that when properly connected allows the EMF to be faithfully transmitted to the reference junction. Thermocouple Wire A pair of wires of dissimilar alloys having EMF-temperature characteristics calibrated to higher temperature levels than the extension type of thermocouple wire. Thermoplastic A material that softens when heated and becomes firm on cooling. Thermoplastic Insulation Jacket compounds (such as PVC, PE and TPE) that will resoften and distort from their formed shapes by heating above a critical temperature peculiar to the material. Thermoset A material that hardens or sets by heat, chemical or radiation cross-linking techniques and which, once set, cannot be resoftened by heating. Thermosetting Insulation that will resoften or distort from its formed shape by heating until a destructive temperature is reached. THHN 90 C, 600 V, nylon jacketed building wire for dry locations. THW Thermoplastic vinyl insulated building wire. Flame-retardant, moisture- and heat-resistant, 75 C dry and wet locations. THW-2 Single copper conductor, stranded and insulated with moisture and flame retardant, sunlight resistant PVC. THWN Same as THW but with nylon jacket overall, 75 C. THWN-2 Same as THWN with 90 C dry or wet location. Tin Overcoat Tinned copper wire, stranded then coated with purple tin. Tinned Copper Tin coating added to copper to aid in soldering and inhibit corrosion. Tinned Copper Conductors Typically specified for use in electrical and electronic equipment. Topcoat Bare (untinned) copper wire, stranded and then coated with purple tin. TPE thermoplastic elastomer Thermoplastic rubber that has mechanical characteristics of thermoset rubbers yet is a thermoplastic. Tracer A means of identifying polarity. Transmission Transfer of electric energy from one location to another through conductors. Transparent Transmitting rays of light so that objects can be seen through the material. Tray Cable A factory-assembled multiconductor or multipair control, signal or power cable specifically approved under the National Electrical Code for installation in trays. Triple A cable consisting of three insulated single conductors twisted together. Triplex A cable composed of three insulated single conductor cables twisted together. T-Stat thermostat wire Tubing A tube of extruded nonsupported plastic or metallic material. Twin Cable A cable composed of two separately insulated stranded conductors laid parallel under a common covering. Twin Coaxial Cable A single cable consisting of two separate coaxial cables laid adjacent and parallel or twisted together. Twisted Pair A twisted pair is composed of two small separately insulated wires twisted together without a common covering. Twisted Triad Any three individually insulated conductors twisted together. UF Thermoplastic underground feeder and branch circuit cable. UFB Underground feeder cable, thermoplastic insulated with conductors rated at 90 C. UHF ultra high frequency 300 to 3,000 Mhz UL Underwriters Laboratories A nonprofit independent organization that operates a listing service for electrical and electronic materials and equipment. Unilay Unilay strand construction is the same as true concentric with the exception that lay length is the same in each layer. Normal direction of lay is left-hand. Unilay Stranding A bunched construction having 19, 27, 37 or any number of strands that might be found in a concentric stranding. USE Underground service entrance cable, rubberinsulated, neoprene or XLP jacketed. USE-2 Same as USE except 90 C wet rating. Valley Any void between the insulated conductors of a cable or between a cable core and its covering. VFD variable frequency drive Cables used to connect alternating current variable frequency drives to alternating current variable frequency motors. VHF very high frequency 30 to 300 Mhz. Video Pair Cable A transmission cable containing low-loss pairs with an impedance of 125 ohms. Volt A unit of electrical pressure. Voltage Electrical potential or electromotive force expressed in volts. Voltage Drop A term expressing the amount of voltage loss from original input in a conductor of given size and length. Voltage Levels Power limited V; low voltage V, medium voltage V. Voltage Rating The highest voltage that may be continuously applied to a wire in conformance with standards or specifications. Voltage Standing Wave Radio The ratio of the maximum effective voltage to the minimum effective voltage measured along the length of mismatched radio frequency transmission line. VW-1 A flammability rating established by Underwriters Laboratories for wires and cables pass a specially designated vertical flame test, formerly designated FR-1. W Oil- and sunlight-resistant, 2000 V, 90 C (-40 C). W/O/G without ground Wall Thickness The thickness of the applied insulation or jacket. Watt A unit of electrical power. WC 70 Same as ICEA S WC Same as ICEA S Wire A single conductor, typically with a covering of insulation. Wire Gauge A measure of the diameter or size of wires. XHHW High temperature (90 C) chemically cross-linked polyethylene-jacketed small-diameter building wire. XHHW cross-linked polyethylene (XLP) insulated building wire. 90 C dry, 90 C wet. XLP cross-linked polyethylene XLPE cross-linked polyethylene Thank you to EMS Partners for providing glossary information. 202 BORDER STATES

203 In this section CROSS AIA XHHW Cable and Connectors. 204 MCHL Cable and Connectors references

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant SSE XHHW-2/RW90 600V WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant and is available in all COLORS in sizes 14 AWG-1000 KCMIL for copper

More information

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW THHN/THWN-2/THW/THWN/TW Listed E-492385 / E-472248 APPLICATIONS THHN/THWN-2 building wire is primarily used for general purpose applications in conduit and cable

More information

PV Solar Wiring Solutions

PV Solar Wiring Solutions Priority Solar Projects Across the US 14 DISTRIBUTION CENTERS PV Solar Wiring Solutions ON TIME ACCURATE FLEXIBLE SERVICE CUSTOM SOLUTIONS Priority Capabilities: Premier Supplier of Wire & Cable Cut to

More information

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

NORMAS DE REFERENCIA AEIC CS 1: ASTM B AEIC CS 1: Especificación para Solid-Type Impregnated-Paper-Insulated Metallic Sheathed AEIC CS2: Especificación para Impregnated-Paper and Laminated Paper- Polypropylene Insulated, High- Pressure Pipe-Type

More information

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013. PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 26 0519 A. Single conductor building wire. B. Metal-clad cable. C. Wiring connectors. D. Electrical tape. E. Wire pulling lubricant. F. Cable ties. 1.2 RELATED

More information

America s Wire Company

America s Wire Company America s Wire Company Dear Customer, We re pleased to provide you with our latest product catalog featuring many cables stocked in our warehouse located in Austin, Texas plus a backup inventory of products

More information

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways. SECTION 16120 WIRE, CABLE AND BUSWAYS PART 1 - GENERAL 1.01 DESCRIPTION: A. This section specifies providing wire, cable and busways. B. Definitions: 1. Cable: Cable having low smoke generating characteristics.

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

SECTION INSULATED WIRE AND CABLE

SECTION INSULATED WIRE AND CABLE SECTION 16120 INSULATED WIRE AND CABLE PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Insulated Wire and Cable, which includes the following items with accessories, and appurtenances:

More information

Una e mpre sa Vi akab l e GLOSSARY.

Una e mpre sa Vi akab l e GLOSSARY. GLOSSARY www.centelsa.com.co CONDUCTORS Cu Copper conductors. CuSn Tinned copper conductor. ACDSR Rectangular soft bare copper wire. ACDSRP Paper insulated rectangular soft bare copper wire. ACDD Bare

More information

ABOUT US. 830 South West Street / Sikeston, MO / F: alanwire.com

ABOUT US. 830 South West Street / Sikeston, MO / F: alanwire.com ABOUT US Alan Wire Company began in 1974 as a small bare copper manufacturer serving the utility and electrical wholesale markets with copper grounding products. Over the last 40 years, the company has

More information

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring. SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

Kaf-Tech Product Specification

Kaf-Tech Product Specification Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-LUMINARY CABLE

More information

Cables ELE E L CT E C R T R IC I C A A L L

Cables ELE E L CT E C R T R IC I C A A L L E LECTRICAL ELECTRICAL Cables July 28, 2009 CONDUMEX INCORPORATED WIRE & CABLE PRODUCT INDEX BUILDING WIRE MTW/THHN/THWN 600 VOLTS COPPER 14 AWG SOLID 750 MCM STRANDED UL 83 XHHW-2 600 VOLTS COPPER 14

More information

Electrical Conductors Line

Electrical Conductors Line Electrical Conductors Line IUSA is present in Mexico, Europe, Asia, the US, Central and South America. Established in 1939. Workforce of over 12,000 employees. Manufacturing facilities established in Mexico

More information

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring. SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola BASIC CONCEPTS IN ELECTRICAL DESIGN Prepared by Engr. John Paul Timola ELECTRICAL CONDUCTORS AND INSULATORS Electrical Conductors substances that offer a very low resistance to current flow. Insulators

More information

colonial electric supply

colonial electric supply colonial electric supply Features: Custom Cutting & Paralleling capabilities to meet your needs 3, 4 or 5 legs available Marked with sequential footage marks every 2 feet* Reduces costly mistakes and saves

More information

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR PART 1 - GENERAL Section 26 05 15 SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR 1.1 Cable shall be 15 kv, shielded, three conductor with ground, stranded copper, with continuously welded and corrugated

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables. Issued 2005/06/01 Section 16122 Wire and Cables (0 1000V) Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 16151 Wire and Box Connectors 0 1000 1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods

More information

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less) SECTION 260523 LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less) PART 1 - GENERAL 1.1 SUMMARY A. Related Documents: 1. Drawings and general provisions of the Subcontract apply

More information

Technical Bulletin #27 Wiring for Architectural Applications

Technical Bulletin #27 Wiring for Architectural Applications 400, du Parc, Saint-Eustache, Québec Canada, J7R 0A1 Tel: +1.450.491.5671 +1.800.665.1166 Fax: +1.450.491.3788 www.heicolighting.com Technical Bulletin #27 Wiring for Architectural Applications WIRE SIZE

More information

Panel 7 Proposals For 2005 NEC Articles 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 382, 394, 396 and 398

Panel 7 Proposals For 2005 NEC Articles 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 382, 394, 396 and 398 Panel 7 Proposals For 2005 NEC Articles 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 382, 394, 396 and 398 The National Electrical Code Technical Correlating Committee Identified concerns with

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

SECTION GROUNDING

SECTION GROUNDING SECTION 16450 GROUNDING PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies general grounding and bonding requirements of electrical and telecommunication installations for personnel safety, equipment

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Change History Date Description of Change Pages / Sections Modified Change Approver Initials 6/15/16 Updated division section from 16124 to 2605 - mgl44 13, removed references to other section 10/17/14

More information

TECHNICAL DATA. A REFERENCE FOR The Electrical Power Industry. www. ElectricalPartManuals. com ANDERSON POWER SYSTEMS, INC.

TECHNICAL DATA. A REFERENCE FOR The Electrical Power Industry. www. ElectricalPartManuals. com ANDERSON POWER SYSTEMS, INC. POWER SYSTEMS, INC. TECHNICAL DATA A REFERENCE FOR The Electrical Power Industry ANDERSON www. ElectricalPartManuals. com TABLE NUMBER INDEX PAGE NUMBER ANGLES 65 Aluminum Angle Conductors, Physical Properties

More information

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation

More information

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance. SERVICE ENTRANCES 3.01 POINT OF ENTRANCE General Service The customer, or the customer s electrician, should provide OPPD with a site plan, load schedule, and voltage requirements when requesting service.

More information

WIRING METHODS CHAPTER 38

WIRING METHODS CHAPTER 38 CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2

More information

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. 37-105VFD MMV-VFD Power Cable Three : kv - 15kV 133% Level Rated 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 150 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR),

More information

1. Section COVER PAGE: remove and replace with new Cover Page, Attached.

1. Section COVER PAGE: remove and replace with new Cover Page, Attached. BID ADDENDUM #04 (BID # 940-13) Greenwich Public Schools District Wide Renovations Electric Generator 290 Greenwich Avenue Greenwich, CT 06830 Date: June 11th, 2013 KSQ Project #: 1317905.00 This Addendum

More information

*** Supercedes: BECO E and COM , , & ***

*** Supercedes: BECO E and COM , , & *** 7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single

More information

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6.2 OVERHEAD SERVICES Wiring of any premises for connection

More information

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section. SECTION 16450 - ELECTRICAL WIRING PART 1 - GENERAL 1.01 RELATED DOCUMENTS The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in

More information

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018 STANDARD INFORMATION Standard Number: UL 83 / CSA C22.2 No 75 / NMX-J-010-ANCE Standard Name: Thermoplastic-Insulated Wires and Cables Standard Edition

More information

NEC Ampacity Data Table (B)(2)(b) Ambient Temperature Correction Factors Based on 40 C (104 F)

NEC Ampacity Data Table (B)(2)(b) Ambient Temperature Correction Factors Based on 40 C (104 F) 05-01-2018 NEC Ampacity Data Table 310.15(B)(2)(b) Ambient Temperature Crection Facts Based on 40 C (104 F) F ambient temperatures other than 40 C (104 F), multiply the allowable ampacities specified in

More information

A. American Society for Testing and Materials (ASTM): Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft.

A. American Society for Testing and Materials (ASTM): Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft. SECTION 260000 ELECTRICAL PART 1- GENERAL 2.1 SUMMARY : Provide complete distribution systems for electrical power as shown on the drawings or required by other sections of these specifications. A. Work

More information

Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.

Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under. Part F: Code Book Questions Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.! (a) tile! (c) carpet squares! (b) carpet!

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 19.10 10 (May 2016) ----------------------------------- Preparing Activity: USACE Superseding UFGS-26 05 19.00 10 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Procurement Services SVC East Fowler Avenue Tampa, Florida (813)

Procurement Services SVC East Fowler Avenue Tampa, Florida (813) Procurement Services SVC 1073 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481 Web Address: https://www.usf.edu/business-finance/purchasing/public-bids/rfi.aspx October 12, 2018 Invitation to

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 16060 Grounding and Bonding This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or

More information

Professional Contractors Residential, Industrial & Commercial

Professional Contractors Residential, Industrial & Commercial Professional Contractors Residential, Industrial & Commercial Rely on Werner Electric for the complete electrical solution. Contractors turn to Werner Electric for product availability and on-time delivery.

More information

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp, TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2011 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.

More information

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes. CHAPTER 35 SERVICES SECTION E3501 GENERAL SERVICES E3501.1 Scope. This chapter covers service conductors and equipment for the control and protection of services and their installation requirements. E3501.2

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information

A. All materials shall be listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

A. All materials shall be listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 16120 WIRE AND CABLE ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 19 An optional keynote

More information

SECTION HORIZONTAL CABLING

SECTION HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY SCOPE OF WORK SECTION 25160 HORIZONTAL CABLING 1. Horizontal cabling is the portion of the cabling system that extends from the work area to the Telecommunications Room or

More information

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 16450 GROUNDING ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 26 An optional keynote to the

More information

600 VOLT 600V, 3 CONDUCTOR (WITH GROUND), FR-EPR OR FR-XLPE INSULATION, PVC JACKET SPECIFICATIONS (FLAME RETARDANT POWER CABLE) (UL TYPE TC-ER) TYPE C3 SPEC 70.0100 PROJECT 196116 REFERENCE: LATEST EDITIONS

More information

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification

More information

Chapter ELECTRICAL CODE

Chapter ELECTRICAL CODE Chapter 19.08 ELECTRICAL CODE 19.08.010 National Electrical Code (NEC) adopted. 19.08.100(1) Definitions, general. 19.08.210.5 Identification of branch circuits. 19.08.210.11(C) Branch circuits required;

More information

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6.2 OVERHEAD SERVICES Wiring of any premises for connection

More information

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990) WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990) ABRASION RESISTANT 600V CABLE NOTE: This "Guide" summarizes the opinions, recommendations, and practices of the Western Underground Committee members

More information

Glossary Of Terms M-1

Glossary Of Terms M-1 Glossary Of Terms ANSI - American National Standards Institute. Armor - A sheath, serving, braid or other layer of metal applied over a cable to increase its mechanical protection. ARR - Association of

More information

SECTION WIRES AND CABLES

SECTION WIRES AND CABLES SECTION 16120 - WIRES AND CABLES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

National Electrical Installation Standard. Type AC Cable and Type MC Cable. NACMA Draft 4

National Electrical Installation Standard. Type AC Cable and Type MC Cable. NACMA Draft 4 National Electrical Installation Standard Type AC Cable and Type MC Cable NACMA Draft 1 1 1 Page - 1 1 1 1 1 1 1 1 1 0 1 0 1 0 1 Table of Contents 1. SCOPE 1.1 Regulatory and Other Requirements. Glossary.

More information

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES Guidelines effective March 5, 2007 NES is committed to providing safe, reliable electric service at a reasonable price for all of our customers. These guidelines offer direction for activities relating

More information

Building Wire CARRYING YOUR ELECTRICITY

Building Wire CARRYING YOUR ELECTRICITY Building Wire CARRYING YOUR ELECTRICITY Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors

More information

Amendment: Accept Comment 7-14

Amendment: Accept Comment 7-14 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M (AMENDMENT) TO: FROM: NFPA Technical Correlating Committee

More information

Standard of Practice - Campus Electrical Distribution System

Standard of Practice - Campus Electrical Distribution System A26.3 Standard of Practice - Campus Electrical Distribution System NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all

More information

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.

More information

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2

More information

Flexible Conduit Systems

Flexible Conduit Systems Flexible Conduit Systems WHEN SAFETY MATTERS THERE S ONLY ONE CHOICE Complies to Australian & New Zealand Standards The Hi-Flex range of flexible conduit & fittings includes products tested to comply with

More information

NEMA Standards Publication No. WC ICEA Publication No. S

NEMA Standards Publication No. WC ICEA Publication No. S NEMA Standards Publication No. WC 71-1999 ICEA Publication No. S-96-659-1999 Standard for Nonshielded Cables Rated 2001-5000 Volts for use in the Distribution of Electric Energy Published by National Electrical

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 GROUNDING AND BONDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Chapter ELECTRICAL CODE*

Chapter ELECTRICAL CODE* Chapter 19.08 ELECTRICAL CODE* 19.08.010 National Electrical Code (NEC) adopted. 19.08.100(1) Definitions, general. 19.08.210.5 Identification for branch circuits. 19.08.210.11(C) Branch circuits required;

More information

SECTION PART 1 GENERAL

SECTION PART 1 GENERAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Grounding of electrical systems and equipment and basic requirements for ground for equipment, circuits, and systems.

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 280.21-300.50 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1000 volts II. Instillation III. Connecting Surge

More information

OVERHEAD SERVICES - SECONDARY

OVERHEAD SERVICES - SECONDARY OVERHEAD SERVICES - SECONDARY Contents - Overhead Services... O-1 General Requirements for Overhead Service... O-2 Names of Parts for Overhead Service... O-3 Service Attachment on an Unguyed Service Mast...

More information

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire Today s Topics Brief Overview of Southwire In-depth Discussion on Aluminum Characteristics Discussion of

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. We were turned down for an underground installation of

More information

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS DAIMLERCHRYSLER MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS ISSUE DATE: 5/1/90 EFFECTIVE DATE: 2/4/92 REVIEW DATE:

More information

National Electrical Installation Standard. Type AC Cable and Type MC Cable. NACMA Draft 4. Page - 1

National Electrical Installation Standard. Type AC Cable and Type MC Cable. NACMA Draft 4. Page - 1 National Electrical Installation Standard Type AC Cable and Type MC Cable NACMA Draft 4 Page - 1 Table of Contents 1. SCOPE 1.1 Regulatory and Other Requirements 2. Glossary 3. IDENTIFICATION OF CABLES

More information

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL SECTION 260513 - MEDIUM-VOLTAGE CABLES PART 1 GENERAL 1.1 SECTION INCLUDES A. Medium voltage cable. B. Cable terminations. C. This specification describes single conductor EPR (Ethylene-propylene-rubber)

More information

8. REVENUE METERING. Operational Excellence Model. 8.1 Introduction

8. REVENUE METERING. Operational Excellence Model. 8.1 Introduction 8. 8.1 Introduction The purpose of this section is to outline requirements of the customer, as set forth herein by PSEG Long Island, as they pertain to Electric Revenue Metering at Primary and Secondary

More information

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents

More information

Appendix C - International NEC Electric Code Amendments

Appendix C - International NEC Electric Code Amendments - International NEC Electric Code Amendments The International NEC Electric Code shall be amended as follows: (Revised Ord 2016-52) Section 220.14(A) Specific Appliances or Loads. At the end of this Sub-Section,

More information

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study PART 1: GENERAL 1.01 Underground Ducts and Manholes A. The work included in this section of the construction standards consists of the design requirements for the complete layout and installation of a

More information

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE). 6.01 GENERAL OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE See Chapter 3, Section 3.01 for more information about point of entrance (POE). In all cases, the customer installs, owns, and maintains the

More information

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013 IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013 2011 National Electrical Code (NEC) Update Statement The National Electrical Code, 2011 Edition, with Appendices,

More information

Tele-Fonika Cable Americas

Tele-Fonika Cable Americas PUMP Cables Tele-Fonika Kable 2 TELE-FONIKA Kable S A, a privately held wire and cable manufacturer headquartered in Krakow, Poland, is one of the largest wire and cable companies in the world. TF operates

More information

PRODUCT SELECTION LOCATOR

PRODUCT SELECTION LOCATOR PRODUCT SELECTION LOCATOR SECTION SPECIFICATION 1 300V Instrumentation Cables 1000 2 600V Instrumentation Cables 2000 3 600V Flexible Control and Power Cables 3000 4 600V Multi Conductor Control and Power

More information

YF /8" YF /2" YF /4"

YF /8 YF /2 YF /4 Wire Over-Braided Flexible Conduit ( YF-705 ) most suitable for demanding industrial wiring applications. *Galvanized steel helically wound with PVC coating and wire over-braid. *Trade size: 3/8"~2" (square

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Receptacles,

More information

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

B. Provide a complete conduit system with associated couplings, connectors, and fittings. SECTION 26 05 33 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 260500. B. Provide a complete conduit system with associated couplings, connectors, and fittings. 1.02 RELATED

More information

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557

SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557 EXHIBIT A - TECHNICAL SPECIFICATION SPECIFICATION FOR 600 VOLT CONTROL AND POWER CABLE SPECIFICATION NO. 557 DATE: March 31, 2000 (REVISED: October 13, 2006) (REVISED: February 14, 2012) (REVISED: January

More information

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR Category 6 Plus Plenum Category 6 Plus Plenum has a cross web design for maximum pair separation. It features sequential footage markings that count down to zero feet -- removing the guess work concerning

More information

26/35kV Copper XLPE Insulation Electric Cable

26/35kV Copper XLPE Insulation Electric Cable 26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32

More information

1.05 Power System Fault and Coordination Study with Arc Flash Calculations

1.05 Power System Fault and Coordination Study with Arc Flash Calculations PART 1: GENERAL 1.01 Underground Ducts and Manholes A. The work included in this section of the construction standards consists of the design requirements for the complete layout and installation of a

More information

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES Elevator Hoistway & Traveling Cables... Designed for high performance and

More information

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5 CHAPTER 23.30 LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2002 EDITION SECTIONS: 23.30.010 Local Amendments to the National Electrical Code 2002 Edition 23.30.020 Certificate of Fitness - Right to

More information

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered. 2012 Edition Redbook 8.0 REVENUE METERING 8.1 INTRODUCTION The purpose of this section is to outline requirements of the Customer, as set forth herein by LIPA, as they pertain to Electric Revenue Metering

More information