"PV2R24A/34A" Series Double Vane Pumps

Size: px
Start display at page:

Download ""PV2R24A/34A" Series Double Vane Pumps"

Transcription

1 "PVR4/34" Series Double Vane s These double pumps incorporate the new PVR4 series pumps for the large volume side, a feature that permits discharge to separate circuits. Graphic Symbol Number ation F- PVR4-6 Special Seals Series Number -L Small Large Volume Volume Nominal Nominal Mounting Displacement Displacement 3 cm /rev cm /rev -R Direction of Rotation E Small Volume Discharge Large Volume Discharge -0 Number * s F: Special seals for phosphate ester type fluids (Omit if not required) PVR4 PVR34 6, 33 4, 4 53, , , 6 93 L: Foot Mtg. F: Flange Mtg. R: Clockwise (Viewed from Shaft End) E: Left 45 : : : 0 0 Refer to. vailable to supply pump with anti-clockwise rotation. Consult Yuken for details.. s: None... "JIS" and N. merican Pipe Flange Kits Pipe flange kits are available. When ordering, specify the kit the number from the table below. PVR4 PVR34 Name of Large Discharge Small Discharge Large Discharge Small Discharge "JIS" F F5---0 F F F5---0 F N. merican Pipe Flange Kit Threaded Connection Socket Welding Butt Welding F F F F "JIS" F5-8-B-0 F5--B-0 F5-06-B-0 F5-3-B-0 F5--B-0 F5-0-B-0 N. merican F5-8-B-090 F5--B-090 F5-06-B-090 F5-3-B-090 F5--B-090 F5-0-B-090 "JIS" F5-8-C-0 F5--C-0 F5-06-C-0 F5-3-C-0 F5--C-0 F5-0-C-0 N. merican F5-8-C-090 F5--C-090 F5-06-C-090 F5-3-C-090 F5--C-090 F5-0-C-090. In case of using socket welding flanges, there is a case where the operating pressure should be set lower than the normal because of strength of the flanges. Therefore, please pay cautious attention to the operating pressure when the socket welding flanges are used.. s dimensions of the pipe flange mounting surface are conformed to SE 4 Bolt Split Flange ( Pressure Series), pipe flanges conforming to the SE s can be used. Notes: Special seals (Viton seals) are required when phosphate ester type fluids are used. (Prefix "F-" to the pipe flange kit number when ordering.) Details of the pipe flange kits are shown on page "PVR4/34" Series Double Vane s

2 VNE PUMPS Specifications Maximum Operating Pressure nti-wear Type Petroleum Base Oils R & O Type Max. Operating Pressure nti-wear Type Water Glycols MPa (PSI) Water Containing Fluids Water Glycols Water in Oil Emulsions Synthetic Fluids Phosphate Esters B PVR4-6 PVR4-33 PVR4-4 PVR4-4 PVR4-53 PVR4-59 PVR4-65 PVR34-6 PVR34-94 PVR34-6 PVR4/34-*-38 PVR4/34-*-6 PVR4/34-*-93 (3050) (3050) 6 (30). (500) 4 (030) 4 (030) 4 (030) 6 (30) 6 (30) 6 (30) (00) (00) (00) (00) (00) (00) 4 (030) 4 (030) 4 (030) "PVR4/34" Series Double Vane s Output Flow & Input Power, Shaft Speed Range and Mass Output Flow & Input Power Small Volume Large Volume Shaft Speed Range r/min Water Containing Fluids Petroleum Base Oils Phosphate Esters Max. Min. Max. Min. pprox. Mass kg (lbs.) Flange Mtg. Foot Mtg. PVR4 "PVR", refer to pages & 3. However, as for displacement of "6" and "33", refer to page 9. "PVR4", refer to pages 9 & (3) 0 (54) PVR34 "PVR3", refer to page (04) 0.5 (6) If the pump is used at speed above 400 r/min, the suction pressure is limited to 0 kpa (0 in. Hg.). "PVR4/34" Series Double Vane s 9

3 Flange Mtg.: PVR4-* - * -F-RE-0/ (4.5) 88(3.46) R(R.6) Large Volume Discharge R4(R.55) 3 (4.84) (.5) Small Volume Discharge 9(.5) 9 (.83) (.354) Key Width 9.56(.364) 9.53(.35) 6(.99) (.5) 35. "D" Thd. "H" Deep (.406) "C" Thd. "F" Deep 0(.6) View rrow X 5 sq. (4.9) Y E 49 (.93) R9 (R.35) Small Volume Discharge 4.6 (.84).(.84) "E" Thd. (.6) Deep 4Places View rrow Y X 35.5 (5.33) 3.5(5.) 439(.8) 3(5.39) 33(5.4) 85 (3.35).5 (.85) 56 (.0) 3 (8.39) 8 (.6) 3 (.) R6 (R.63).5(.689) Through 48 PVR4- * - * -F-RE-0 PVR4- * - * -F-RE-090 "C" Thd. M6 5/8- UNC "D" Thd. M4 /-3 UNC "E" Thd. M0 3/8-6 UNC Dimensions mm (Inches) F H 9 (.5) (.8) (.83) (.83) Foot Mtg.: PVR4-* - * -L-RE-0/090.5(.689) Through 6(.0) Spotface DIMENSIONS IN MILLIMETRES (INCHES) (.8) 3(.9) 09.5 (4.3) 44.5 (9.63) 35.5(9.) 0 (4.33) (.08) 38.0(.5000) 38.05(.4980) 4.36(.668) 4.8(.66) (5.000) (4.998) 60(6.30) Sq (3.000) (3.86) 3 60 (5.6) (.36) 45(5.).5.5 (4.66) (4.66) 4 (0.9) For other dimensions, refer to "Flange Mtg.". 98 "PVR4/34" Series Double Vane s

4 VNE PUMPS Flange Mtg.: PVR34-* - * -F-R-0/ (9.) 00(3.94) Small Volume Discjarge 8(.0) R6 R(R.43) (R.63) 35.5(5.33) 30.(5.6) 65 (.56) 0(4.33) 58. (.3) 90 (3.54) 30. (.89) 5 (5.98) "J" Thd. "N" Deep 4 (5.59).8 (3.063) R4 (R.55) 480.5(8.9) 48 Large Volume Discharge 36(.4) (.83) 35. (.406) 9 (.354) "C" Thd. "K" Deep 33 (5.4) 6(.99) "D" Thd. "L" Deep 85 (3.35).5 (.85) 56 (.0).5(.689) Through Places 3 (8.39) 8 (.6) B "PVR4/34" Series Double Vane s PVR34- * - * -F-R-0 PVR34- * - * -F-R-090 "C" Thd. M6 5/8- UNC "D" Thd. M4 /-3 UNC "J" Thd. M0 /6-4 UNC Dimensions mm (Inches) K L N 9 (.5) (.83) (.8) (.83) 9 (.5) 0 (.9) Foot Mtg.: PVR34-** - -L-R-0/090 DIMENSIONS IN MILLIMETRES (INCHES) (.08) (.8) 3(.9) 09.5 (4.3) 44.5 (9.63) Key Width 9.56(.364) 9.53(.35) 38.0(.5000) 38.05(.4980) (.5) 4.36(.668) 4.8(.66) (5.000) (4.998) 48 3 (.) R6 (R.63) 60(6.30) Sq..5(.689) Through 6(.0) Spotface 6. (3.000) 3 (5.6) 98 (3.86) 60 (.36).5 (4.66) 45 (5.).5 (4.66) 4 (0.9) For other dimensions, refer to "Flange Mtg.". "PVR4/34" Series Double Vane s 99

5 Spare Parts List PVR4-* - * - * -RE-0/090 PVR34-* - * - * -R-0/ Cartridge Kits PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * PVR * -RE-0 * Cartridge Kit 8 Small Volume 9 Large Volume CPVR3-6-L-4 CPVR3-33-L-4 CPVR3-4-L-4 CPVR3-4-L-4 CPVR3-53-L-4 CPVR3-59-L-4 CPVR3-65-L-4 CPVR33-6-L-3 CPVR33-94-L-3 CPVR33-6-L-3 CPVR4- -R-0 CPVR34- -R-0 Note: The marks are a spaces for large volume pump nominal displacement. Referring to the model No. designation on page 96, write correct nominal displacement figures. Seals & Bearings List of Seal Kits Item Name of Parts Bearing Oil Seal Bearing PVR4 ISD SO-NB-G40 SO-NB-G05 SO-NB-G85 SO-NB-P46 SO-NB-50 SO-NB-G80 Part PVR ISD SO-NB-G40 SO-NB-G35 SO-NB-G5 SO-NB-3 SO-NB-50 SO-NB-G Qty. PVR4- * - * -RE-0 * PVR34- * - * -R-0 * Seal Kit KS-PVR4-0 KS-PVR34-0 When ordering seals, please specify the seal kit number from the table above. Note: ) The o-rings under item. Nos. 5 and 6 are included in the large volume pump catridge kit and those under item. Nos. 3 and 4 in the small volume pump cartridge kit. ) For pumps for phosphate ester type hydraulic fluids, different part Nos. are used. Please contact us. 00 "PVR4/34" Series Double Vane s