1 Connecting the world through technology and quality G. K. Enterprises (P) Ltd. An ISO 9 : 28 Certified Company Unit I - C-, Sector 58, Noida -23 (U.P.), (India) Unit II - C - 6, Sector 58, Noida -23 (U.P.), (India) Phone:+(2) ,25885 Fax:+() contact@gkayindia.com An ISO 9 : 28 Certified Company

2 Introduction Connecting to safer world Welcome to the world of GEEKORE where quality and services are the corner stones of enterprise. GEEKORE is one of the leading ISO 9:28 accredited organization in the field of design/ manufacture of various types of precision wires & cables including. kv control, Instrumentation and high temperature cables GEEKORE has established itself in wide range of industries including private industries, semi govt. and govt. sectors in various applications like: Electronics in radar, antenna etc Railway signaling Instrumentation of steel and cement plants Instrumentation of nuclear power plants Winding of submersible pumps Cabling in Instrument transformers Luminaries & Appliances Product Spectra LT Control s Armoured & Unarmoured Individually & Collectively Screened Instrumentation/Signal s Armoured & Unarmoured Individually & Collectively Screened Thermocouple Compensating / Extension s PVC Insulated Armoured & Unarmoured upto 9 C High Temperature Teflon Insulated upto 25 C Fibre Glass Insulated upto 6 C FRPVC / FRLS PVC / HFFR Equipment Wires Our work is manned by team of professionally and technically qualified engineers. We offer the latest generation product with continuous quality improvement in order to provide product and service excellence to customers. Submersible Winding & 3 Core Flat s Fluoropolymer Insulated Equipment Wires Extruded FEP Wires Wrapped PTFE Wires Extruded ETFE/PFA Wires High Temperature Multi-core s HR Power for Kilns High Voltage for Transformers RG Coaxial s Heating Wires and s Under tiles heaters Under carpet heaters In-concrete heaters Low wattage heaters for special applications Heathing Mats "Total quality monitoring systems are adopted to ensure consistent, reliable, high and quality products through the optimum use of the company's resources. Our principal asset is our people, highly motivated and trained professionals." Mr. Naresh Agarwal (M.D.)

3 LT Control (Unarmoured) IS : 554 (Pt-I) - 88 LT Control (Armoured) IS : 554 (Pt-I) - 88 Outer Sheath Inner Sheath Insulation Technical Data : Operating Voltage : volts Temperature Range : to 9 deg C FRLS Properties : as per IS High Voltage Testing : at 5 kv. minute core to core Resistance : 2. ohm/km for.5 sq 8.4 ohm/km for 2.5 sq Insulation Resistance : Nom. Mohm x km at 2 deg C Outer Sheath Armouring Inner Sheath Insulation Technical Data : Operating Voltage : volts Temperature Range : to 9 deg C FRLS Properties : as per IS High Voltage Testing : at 5 kv. minute core to core Resistance : 2. ohm/km for.5 sq 8.4 ohm/km for 2.5 sq Insulation Resistance : Nom. Mohm x km at 2 deg C Part No. No.of Cores & Cross Sectional No x 2 Thickness of PVC Insulation (Nom.) Thickness of PVC Inner sheath Extruded (min) Thickness of PVC Outer shealth (Nom.) Appro x. O.D. Approx. Net Weight of Kg / Km Current Rating Direct in Ground Amps. In Air / Duct Amps x x x x x x x x x x x x X X X X X x x x x x x x x x x Part No. No. of Cross Selection No x 3 Thickness of PVC Insulati on (Nom.) Thickness Inner sheath Extruded (min.) Strip Size Strip Armored Thickness of PVE Outer Sheath (Min) Approx. OD Approx. Net wight of Kg / km Round Wire Dia Wired Armoured Thickness of PVC Outer Sheath (Min) Approx. OD Approx. Net wight of Kg / km Current Rating Direct in Ground Amps 25 2 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x In Air Duct. Amps

4 LT Control s Ordering Code: Example: 2 core.5 sq Annealed bare copper conductor, HR PVC Insulation armored, with PVC Sheath (type ST2) FRLS 2C.5A / ABC / 2 / / FRLS* * MENTION, IF REQUIRED Part Number Identification COLOR CODE / SHEATH CODE CONDUCTOR CODE SIZE CODE (refer Table) CODE DETAIL Application Code ABC ATC Insulation / sheath code Annealed bare copper Annealed tinned copper Type A / Type ST 2 Type C / Type ST2 Color Code Colored cores 2 Numbered Cores Crimped connections Soldered connection - deg C temperature - 9 deg C temperature As per user's requirement As per user's requirement Instrumentation s Technical Data: Voltage rating :. kv AC High Voltage Testing : 2 kv AC for second core to core Insulation resistance : Nom. Mohm x km Max. Temperature : Upto deg C for PVC and 9 deg C for HRPVC Bending radius :.5 x cable dia Drain wire :.5 sq ATC drain wire Insulation color : White & blue for pair, numbering for pair identification Sheath Color : Sky blue SIZE CODE PAIRS X CROSS sectional area (sq ) Overall diameter () Overall screened Individual and overall screened P5 P X.5.2-2P5 2P X P5 4P X P5 6P X P5 8P X P5 P X P5 2P X P5 6P X P5 2P X P5 P X P5 3P X SIZE CODE PAIRS X CROSS sectional area (sq ) Overall diameter () Overall screened Individual and overall screened P5 P X P5 2P X P5 4P X P5 6P X P5 8P X P5 P X P5 2P X P5 6P X P5 2P X P5 P X P5 3P X P P X P 2P X P 4P X P 6P X P 8P X P P X P 2P X. 3. 6P 6P X P 2P X P P X P 3P X P5 P X P5 2P X P5 4P X P5 6P X P5 8P X P5 P X P5 2P X P5 6P X P5 2P X P5 P X P5 3P X

5 Instrumentation s Ordering Code: Example: 2 pair.5 sq Annealed bare copper conductor, HR PVC Insulation, individual & overall screened by al-mylar tape with ATC drain wire, inner sheath by HRPVC, armored with GI stripe 4 x.8, PVC Sheath (type ST2) FRLS 2P5 / ABC / HP / IO / HS / S / FRLS* Part Number Identification Code Inner T B Core insulation Details Annealed tinned copper Annealed bare copper Armoring SHEALTH CODE SCREENING PV PVC (type A as per IS: ) CODE CONDUCTOR CODE HP HR PVC (Type C as per IS: ) PE XL Screening O IO B Laying P T Inner / Outer sheath Polyethylene Cross Link PE SIZE CODE (refer Table) Overall screening by al mylar with drain Individual & overall screening by al mylar with drain wire Tinned copper braiding Pairs Triads PS HR PVC (Type ST as per IS: ) HS HR PVC (Type ST2 as per IS: ) Armoring A R S.9 Round wire.4 round wire 4 x.8 Flat Stripe Submersible Winding Wires & 3 Core Flat s for Submersible Pump Motors GEEKORE manufactures Wide Range of submersible winding wires for 'Wet type' motors. With years of experience and expertise, we have a leading edge over many other manufacturers. PVC Insulated Winding Wires The PVC insulated winding wire is being manufactured with specialy developed compound which can withstand voltage fluctuation and has very high insulation resistance even at elevated temperatures. Range :.8 to 3.5 conductor dia. Wrapped Winding Wires These wire are being manufactured by wrapping process using synthetic films. These type of wires have outstanding electrical; mechanical and chemical properties and can withstand water abrasion and frictional losses, saves space / size cost and work in all type of weather conditions, in water filled submersible motors. Range :.3 to 2. conductor dia. Three Core Flat s W Flexible Copper PVC insulation of Cores (Red, Yellow, Blue) T PVC Sheath (Black) The Strand diameter is nominal. However, construction of conductor is designed to comply with the requirements of conductor resistance as per IS 83 : 84 The individual conductors are made from bright-annealed electrolytic copper. s are insulated with specially formulated PVC in red, Yellow and blue color. Insulating sheathing compounds are specially formulated to give non glossy surface for enhanced life of the cable suitable from - 5 to + deg C. Use of color pigment only on skin improves the insulation resistance value of PVC and increases the life of the cable. These cables are confirming to IS:694:9. GEEKORE also manufactures 3 Core Flat with Copper XLPE Insulation and HR PVC Sheath # Specification is generally conforming to IS:98 (part-) 88. # XLPE insulation enhances the current rating and overload capacity for the same size. #These cables are lighter in weight due to low density of XLPE over PVC. 3 Core Flat s in copper conductor with PVC vs. XLPE core Insulation Insulation Sheath Overall Dimensions Current No./Strand Thickness Thickness Width Height Resistance Carrying 2 C Capacity (Nom) (Nom) (Nom) (Approx) (Approx) 4 C PVC XLPE PVC XLPE PVC XLPE PVC XLPE Sq. Ohms / km Amps. 3/.86.6 n/a.9 n/a 9.85 n/a 4.55 n/a /.3.6 n/a.9 n/a.3 n/a 4.95 n/a / / / / / / / /.3.4 n/a 2.2 n/a 4.2 n/a.5 n/a /.45.4 n/a 2.2 n/a 46.6 n/a. n/a /.3.4 n/a 2.2 n/a 4.2 n/a.5 n/a /.5.6 n/a 2.4 n/a 53. n/a 2.5 n/a. 65

6 Thermocouple Extension / Compensating Grade Color Code Thermocouple Combination Type Grade DIN IEC ANSI JIS IS Deviation in Temp. ( C) German to Din 43 International Color Code TO IEC 5843 : 89 American to ABSU/MC96. Japanese to JIS C 6-8 Indian to IS 884:84 At 5 C Ambient At C Ambient At 2 C Ambient K Extension.6. K Compensating T Extension.3.5 J Extension.6. N Extension.5.9 E Extension.8.. R Compensating.9..3 S Compensating.9..3 B Compensating.9..3 Flat / Non Screened / Non Armored (PVC/PE insulated) P P P2 P2 P84 P Cross Sectional. sq..2 sq..5 sq..5 sq.. sq..3 sq Flat (or Twisted) / Screened / Non Armored (PVC insulated) PS PS P2S P2S P84S P63S Screened & Armored (PVC insulated) P2SA P2SA P84SA P63SA P6SA P52SA P548SA Cross Sectional. sq..2 sq..5 sq..5 sq.. sq..3 sq Cross Sectional.5 sq..5 sq.. sq..3 sq..3 sq..5 sq.5 sq x.2 x.5 x.8 x.3 4 x.3 3 x. x.2 x.5 x.8 x.3 4 x.3 3 x. x.8 x.3 4 x.3 3 x. x.3 2 x.3 48 x.2 Temp. Range C -25 C TO +2 C - C TO +5 C -25 C TO + C -25 C TO +2 C -25 C TO +2 C -25 C TO +2 C - C TO + C - C TO + C - C TO + C Nom Outer Diameter () 4.2 x x x x x x 4. Nom Outer Diameter () 4.3 x x x x x x 4. Nom Outer Diameter () Fluoropolymer Insulated and Sheathed (upto 25 Deg C) Cross Sectional Nom Outer Diameter () P P P2 P2 P84. sq. x x..2 sq. x x sq. x x sq. x.3 3. x sq. 4 x.3 4. x 2.3 P sq 3 x. 5. x 2.8 Fluoropolymer Insulated and Sheathed, SS Braided (upto 25 Deg C) Cross Sectional Nom Outer Diameter () HS HS H2S H2S H84S. sq. x x..2 sq. x x sq. x x sq. x.3 4. x sq. 4 x x 2. H63S 6.3 sq 3 x. 5.4 x 3.2 Fiber Glass Insulated Sheathed (upto 6 Deg C) Cross Sectional F F F2 F2 F84 Nom Outer Diameter (). sq. x x..2 sq. x x sq. x x sq. x.3 4. x sq. 4 x x 2. F sq 3 x. 5.4 x 3.2 Fiber Glass Insulated and Sheathed, SS Braided (upto 6 Deg C) Cross Sectional Nom Outer Diameter () FS FS F2S F2S F84S. sq. x x 2..2 sq. x x sq. x x sq. x.3 4. x sq. 4 x x 2. F63S 6.3 sq 3 x. 5.4 x 3.2 Ordering Code: Example: 2 pair, Awg 6, KX thermocouple screened and armoured PVC insulated, ANSI color coded KX / 2 / P6SA / ANSI Color Code (Refer List) No. of Pair CODE

7 RTD for PT Sensor (Color Coding as per Din) HR PVC / ZHFR / TPE HDPE Insulated (for Ambient Temperature upito 5 C) PVC / Screening / PVC H3C2S H4C2S H6C2S H3C84S H4C84S H6C84S Description 3C x 2 4C x 2 6C x 2 3C x 8 4C x 8 6C x 8 Cross Sectional.5 sq.5 sq. sq. sq. sq. sq PVC / Screening / PVC / GI ARMORING / PVC H3C2SA H4C2SA H6C2SA H3C84SA H4C84SA H6C84SA Description 3C x 2 4C x 2 6C x 2 3C x 8 4C x 8 6C x 8 Cross Sectional.5 sq.5 sq.5 sq. sq. sq. sq x.3 x.3 x.3 4 x.3 4 x.3 4 x.3 x.3 x.3 x.3 4 x.3 4 x.3 4 x.3 Outer dia () Outer dia () PVC Insulated Equipment Wires (with Copper ) Nom. Cross section area (sq ).2 Single wire Nom. Outer dia () Max Resistance ( Ω/km)at 2 C stranding Stranded wire Outer dia Max Resistance () ( Ω/km)at 2 C stranding Fine Stranded wire Outer dia Max Resistance () ( Ω/km)at 2 C x x x x x x x x x x x x x x x x x x x x x x x x x stranding.4 66 Bare 66 Bare Tinned V V copper Tinned 66 Bare Tinned copper V V copper copper V V copper copper x x Heat Resistant (PTFE) Insulated Silver Plated Copper (for Ambient Temperature upto C) PTFE / PTFE H3C H4C H6C H3C2 H4C2 H6C2 Description 3C x 4C x 6C x 3C x 2 4C x 2 6C x 2 Cross Sectional. sq. sq. sq.5 sq.5 sq.5 sq x.2 x.2 x.2 x.3 x.3 x.3 Outer dia () Part Number Identification Annealed Bare Copper Annealed Tinned Copper Single Strand Wire Stranded Fine Stranded Wire Insulation PVC Fire Retardant Fire Retardant, Low Smoke Code ABC ATC Code SS MS FS Code P FR FRLS Technical Characteristics Soft annealed copper conductor with 99.9% cu purity Insulation by General purpose PVC for deg C application HR PVC for 85 deg C and FRLS /FR PVC for 9 deg C application XLPE insulation with steam curing for 9 deg C application. ZHFR RoHS grade Tinned copper with PVC as per requirement. Specification referenced: IS 83 and VDE 295 for conductor IS 583, IS 694, IS 554 and VDE 282 Testing: % spark test as per IS 694 and IS 554 and insulation resistance Aging test of PVC insulation PTFE / PTFE / SS H3CS H4CS H6CS H3C2S H4C2S H6C2S Description 3C x 4C x 6C x 3C x 2 4C x 2 6C x 2 Cross Sectional. sq. sq. sq.5 sq.5 sq.5 sq x.2 x.2 x.2 x.3 x.3 x.3 Outer dia () Zero Halogen Fire Retardant Polyurethane High Density Polyethylene Low Density Polyethylene XLPE ZHFR PUR HDPE LDPE XLPE Ordering Code Example:.5 Sq.. ATC, Single strand, PVC insulated Volts, Red Color ATC /.5 / SS / P / / Red Color Code Voltage Rating Insulation Code Sq material

8 Fluoro Polymer Section Extruded FEP Insulated Wire as per MIL W 688 / NEMA HP4 / JSS 534 CONDUCTOR MIL-W-688/3 TYPE-KT 25 V (RMS) MIL-W-688/3 TYPE-K 6 V (RMS) MIL-W-688/3 TYPE-KK V (RMS) Why Fluoropolymer? Compact in size. Suitable for light weight application. Suitable for wide range of temperature (- C to + C) Having high insulation resistance. Inert to most chemical and fluid even at high temperature and pressure. Excellent flex life Mention Required Color Insulation Name Process Temperature Range ETFE PTFE FEP PFA Extrusion Spirally Wrapped, Heat Fused Extrusion Extrusion - C to 5 C -2 C to C -2 C to 2 C -2 C to C NO. OF STRANDS STRAND SIZE DIA. COND. DIAM. (NOM.) CS AREA (NOM.) F36SKT.9.99 F36SK.4.25 F36T F34SKT.89.9 F34SK.4.35 F34T F38SKT.89.9 F38SK.4.35 F38T FSKT.8.2 FSK..2 FT F32SKT.2. F32SK.2.4 F32T F36SKT.2. F36SK.2.4 F36T FSKT.9.2 FSK..3 FT F3SKT..3 F3SK F3T F34SKT..3 F34SK F34T FSKT.3.68 FSK.3.52 FT F28SKT.3.58 F28SK F28T F32SKT.3.58 F32SK F32T F2SKT..42 F2SK.4.6 F2T FSK FT F3SK F3T F8SK.6.96 F8T F29SK F29T F3SK* F3T F3SK* F3T F6SK F6T F2SK F2T F3SK* F3T F4SK F4T F25SK F25T F28SK F28T F3SK F3T FSK FT F3T F29T F2T9 * Sizes not covered in JSS/ MIL Specifications + For Nickel plated copper replace S by N, e.g., 2//25 NPC, type E is F25NE + Mention required color

9 CONDUCTOR MIL-W-688/6 TYPE-ET 25 V (RMS) MIL-W-688/5 TYPE-EE V (RMS) MIL-W-688/4 TYPE-E 6 V (RMS) SIZE NO. OF STRANDS DIA. COND. DIA. (NOM.) CS AREA (NOM.) STRAND H36SET H34SET H38SET HSET H32SET H36SET HSET H3SET H34SET HSET H28SET H32SET H2SET H36SE H34SE H38SE HSE H32SE H36SE HSE H3SE H34SE HSE H28SE H32SE H2SE HSE H3SE H8SE H29SE 6H3SE* H3SE* H6SE H2SE 4H3SE* H4SE H25SE 3H28SE 65H3SE 3HSE H36SEE H34SEE H38SEE HSEE H32SEE H36SEE HSEE H3SEE H34SEE HSEE H28SEE H32SEE H2SEE HSEE H3SEE H8SEE H29SEE 6H3SEE H3SEE H6SEE H2SEE 4H3SEE H4SEE H25SEE 3H28SEE 65H3SEE 3HSEE 5H3SEE 33H29SEE 33H2SEE CONDUCTOR MIL-W-59/ 6 V (RMS) MIL-W-59/9 V (RMS) SIZE DIA. COND. DIA. (NOM.) CS AREA (NOM.) STRAND E36T E34T E38T ET E32T E36T ET E3T E34T ET E28T E32T E2T ET E3T E8T E29T 6E3T E3T E6T E2T 4E3T E4T E25T 3E28T 65E3T 3ET E36T9 E34T9 E38T9 ET9 E32T9 E36T9 ET9 E3T9 E34T9 ET9 E28T9 E32T9 E2T9 ET9 E3T9 E8T9 E29T9 6E3T9 E3T9 E6T9 E2T9 4E3T9 E4T9 E25T9 3E28T9 65E3T9 3ET9 5E3T9 33E29T9 33E2T9 * Sizes not covered in JSS/ MIL Specifications + For Nickel plated copper replace S by N, e.g., 2//25 NPC, type E is H25NE + Mention required color + Mention required color WRAPPED PTFE INSULATED WIRE AS PER MIL W 688 / NEMA HP3 / JSS 534 Extruded ETFE Insulated Wire as per MIL-W-59 NO. OF STRANDS

10 MULTI CORE / COMPOSITE CABLE As per JSS 538 Technical Data: Voltage Rating : see table below Size : 32 to 6 Insulation Resistance : Mohm x km Braiding Coverage : 85% minimum Max. Temperature : upto deg C Bending Radius :.5 x cable dia. Color Coding : as per customer requirement Selection Creteria a) Material Code Material Application Quality Standard S Silver plated copper Soldered connection ASTM B 298 N Nickel plated copper Crimped connection ASTM B 355 T Tin plated copper Soldered connection IS: b) Insulation Material Code Material Temperature range Quality Standard P PTFE (wrapped) -2 C to + C Mil W 688/JSS 534 F FEP (extruded) - C to +2 C Mil W 688/JSS 534 E ETFE (extruded) - C to +5 C Mil W 59 A PFA (extruded) -2 C to + C jasfjs; c) Voltage Rating Code Rated Voltage Test Voltage ( minute) At core stage A 25 V.5 kv B 6 V 2. kv C V 3. kv d) Core Laying Manner Code Manner C Core P Pair T Triad Q Quad e) Screened Material Code Material Applicable with sheath Material SB Silver plated copper braiding With all sheath materials NB Nickel plated copper braiding With all sheath materials TB Tin plated copper braiding All sheaths, Except PTFE MD Mylar tape with ATC drain wire All sheaths, Except PTFE b) Insulation Material Code Material Application Quality standard PS PTFE (wrapped) Higher temperature range + deg C JSS 538 FS FEP (extruded) Higher temperature range +2deg C* JSS 538 AS PFA (extruded) Higher temperature range + deg C* PU PUR (extruded) Highest abrasion resistance VDE 282 PV FRLS (extruded) High abrasion resistance IS: * Maximum cable diameter must be 8 Ordering Code Example: 6PS2(32)PBMDPUSS 6 pair 2//32 silver plated copper conductor, PTFE Insulation, 6 V, screened by al-mylar tape with ATC drain wire, Sheath by PUR, SS over braiding 6P S 2(32) P B MD PU-SS** ** Mention, if required SS Over-braiding Sheathing by PUR Mylar tape with ATC drain wire.5 sq Voltage rating 6 V Insulation material PTFE Inner conductor size Core conductor Silver plated cu 6 pairs

11 Heat Resistant Power For Kilns In Steel & Cement Plants Technical Data Temperature Range : -4 C to +4 C for fixed installation Working voltage : V Insulation Resistance : Min M x km Test Voltage : 5 kv AC Min Bending Radius :.5 x cable dia Environmental properties : Resistant to any chemical oil, water proof cable Sheath Color : Outer PTFE sheath black Construction : Stranded annealed bare copper per DIN VDE 295 cl.5 or IS Core Insulation : PTFE Twisting : 3 or 4 core planetary twisted Isolator : Kapton Outer sheath : PTFE / Mica taped / Fibre glass or Asbestos Overbraiding : Stainless Steel braiding High Voltage Leads for Current / Power Transformer 5 kv AC Application Technical Data: Voltage Rating : 5 kv AC High Voltage Testing : kv AC for second and 6.5 kv for 5 minutes Oil Compatibility (tan delta) : Insulation resistance : More than Mohm x km Max. Temperature : Upto deg C for PTFE and 5 deg C for ETFE Bending Radius :.5 x cable dia Environment Properties : Resistant to transformer oil, chemical or ultra violet rays Insulation Color : White Construction a) ATC ABC NPC b) Insulation PTFE ETFE Annealed Tinned Copper Annealed Bare Copper Annealed Bare Copper Polytetrafluoroethylene Ethylenetetrafluoroethylene* (Tefzel) 2 Core Description Outer Dia () 2C X 25 sq 2C X 6 sq 8 2C X sq 2 2C X 6 sq 2C X 4 sq 2C X 2.5 sq m 8 2C X.5 sq m 3 Core Description Outer Dia () 3C X 25 sq 3C X 6 sq 2 3C X sq 4 3C X 6 sq 2 3C X 4 sq 3C X 2.5 sq 9 3C X.5 sq.5 4 Core Description Outer Dia () 4C X 25 sq 29 4C X 6 sq 4C X sq 5 4C X 6 sq 3 4C X 4 sq 2 4C X 2.5 sq 4C X.5 sq 8.5 Cross Section (sq ) Construction Max Resistance (ohm / mtr) Outer Diameter max. (). 42 X x x x x x x x x x x PTFE ETFE

12 Heating Wires and s ENJOY COMFORT ZONE FROM GEEKORE Exhibit more accurate control Lower maintenance and operating cost Time saving during start up Safety guidelines as per BS EN 633-: Under Tile Heating (UTH) Element CONSTRUCTION : Single/Multi-strand alloy, Cu, SS Insulation : Fluoropolymer Shielding : Annealed Tinned copper braid Jacket : Fluoropolymer TECHNICAL DATA Supply Voltage 23 V Temperature range -2 deg C to +2 deg C Maximum output: 5 W/mtr Superior flexibility Flame retardant, inert to spark, any chemical or acid Element diameter : 2.2 (max) Length (Mtr) Resistance (Ohm per Mtr) In Concrete Heating (ICH) Element Technical Data: Supply Voltage 23 V Temperature range -2 deg C to +9 deg C Linear Wattage: 3 Watt / mtr Superior flexibility Flame retardant, Low smoke Element diameter : 5. (max) Printing: e.g. GEEEKORE ICH 2W, Single Core in Concrete Heaters (ICH) Part No. Wattage 23 v Element Length (mtr) CONSTRUCTION: : Stranded alloy Insulation : XLPE or Additional layer of PTFE in the innermost layer for superior performance and snow melting application Braiding : Annealed bare copper Sheath : PVC Color coding : Orange for single core ICH and Violet for twin core cable ICH Resistance (ohm/mtr) ICH3S 3.63 ICH4S ICH5S ICH5S ICH9S ICH5S ICH2S 2 4. ICH5S 5 5. ICH8S ICH25S ICH3S 3.8 ICH45S ICH55S ICH6S TWIN CORE* IN CONCRETE HEATERS (ICH) Part No. Wattage 23 v Element Length (mtr) Resistance (ohm/mtr) ICH3T ICH4T ICH5T ICH5T ICH9T ICH5T ICH2T ICH5T ICH8T ICH25T ICH3T 3.9 ICH45T ICH55T ICH6T 6 2.2

13 Under Carpet Heating (UCH) Element Heating Mats CONSTRUCTION : Single/Multi-strand alloy, Cu, SS Insulation : Fluoropolymer TECHNICAL DATA Supply Voltage 23 V Temperature range -2 deg C to +2 deg C Maximum output: 5 W/mtr Superior flexibility Flame retardant, inert to spark, any chemical or acid Element diameter :.5 (max) Part No. Wattage (W) Length (mtr) Resistance (ohm.mtr) Jacket Color UCH Wh/bk UCH Wh/br UCH Wh/rd UCH Blue UCH Wh/Yw UCH Yellow UCH Brown UCH Green UCH.63 Red UCH Grey UCH Brown UCH Orange UCH Black UCH Violet UCH White TECHNICAL DATA Twin core element; wattage 5, 2 Watt per Sq.mtr; overall thicknes 3. max. Mat width.5 mtr Mesh size x or 2x2 Spacing between the cables as per customer specs. Heating Mat (2 W / sq mtr) Part No. GKCZ-2-.M2 GKCZ-2-.5M2 GKCZ-2-2.M2 GKCZ-2-2.5M2 GKCZ-2-3.M2 GKCZ-2-3.5M2 GKCZ-2-4.M2 GKCZ-2-4.5M2 GKCZ-2-5.M2 GKCZ-2-6.M2 GKCZ-2-.M2 GKCZ-2-8.M2 GKCZ-2-9.M2 GKCZ-2-.M2 GKCZ-2-.M2 GKCZ-2-2.M2 Size of Mat Sq meter Heating Mat (5 W / sq mtr) Part No. GKCZ-5-.M2 GKCZ-5-.5M2 GKCZ-5-2.M2 GKCZ-5-2.5M2 GKCZ-5-3.M2 GKCZ-5-3.5M2 GKCZ-5-4.M2 GKCZ-5-4.5M2 GKCZ-5-5.M2 GKCZ-5-6.M2 GKCZ-5-.M2 GKCZ-5-8.M2 GKCZ-5-9.M2 GKCZ-5-.M2 GKCZ-5-.M2 GKCZ-5-2.M2 Size of Mat Sq meter Wattage Wattage Element Length (mtr) Element Length (mtr) Element Resistance (ohm) Element Resistance (ohm)

14 Low Wattage s for Special / customized Application: Certificates: Low wattage heating element for mirror antifogging Low wattage heating element for door antifreezing ISO CERTIFICATE LCSO Low wattage heating element for towel rail heater Low wattage Tape heating IS IS