1 Aug. 018 T&D Optional Catalog Temperature Sensors TR p. TR p. TR p. TR p. TR p. TR p. TR p.5 TR p.6 TR p.6 TR p.6 TR p.7 Pt Sensors -- p.8 TR p.4 TR p.4 TR p.4 TR p.5 Sensor Extension Cables TR-1C p.9 TR p.9 TR-C p.9 TR p.5

2 Compatible TR-0106 TR-71wf / 71nw, TR-7U Discontinued TR-701NW/701AW, TR-71Ui/7Ui, TR-71U/7U, TR-71W/7W, TR-71S/7S TPE Resin-Shielded Sensor TPE Mold Provided with TR-71wf and TR-71nw -40 to 110 C -50 to 115 C Avg. ±0. C at -0 to 80 C, Avg. ±0.5 C at -40 to -0 C, 80 to 110 C Response Time (90%) Approx. 190 sec. ( in air ) None TR-006 Screw-down Sensor M Crimp Terminal (aluminium) ShrinkTube -40 to 110 C -50 to 115 C Avg. ±0. C at -0 to 80 C, Avg. ±0.5 C at -40 to -0 C, 80 to 110 C Approx. 10 sec. ( in air ) None TR (SUS04) -40 to 110 C -50 to 115 C Avg. ±0. C at -0 to 80 C, Avg. ±0.5 C at -40 to -0 C, 80 to 110 C Approx. 11 sec. ( in agitated water ) (stainless protection tube)

3 TR-71wf / 71nw, TR-7U Discontinued TR-701NW/701AW, TR-71Ui/7Ui, TR-71U/7U, TR-71W/7W, TR-71S/7S TR (SUS04) -40 to 110 C -50 to 115 C Avg. ±0. C at -0 to 80 C Avg. ±0.5 C at -40 to -0 C, 80 to 110 C Approx. 15 sec. ( in agitated water ) (stainless protection tube) Can be extended by meters with the Extension Cable TR-1C0 TR (SUS04) -40 to 110 C -50 to 115 C Avg. ±0. C at -0 to 80 C, Avg. ±0.5 C at -40 to -0 C, 80 to 110 C Approx. 10 sec. ( in agitated water ) (stainless protection tube) TR (SUS16) -40 to 110 C -50 to 115 C Avg. ±0. C at -0 to 80 C, Avg. ±0.5 C at -40 to -0 C, 80 to 110 C Approx. 11 sec. ( in agitated water ) (stainless protection tube)

4 TR-71wf / 71nw Discontinued TR-701NW/701AW, TR-71Ui, TR-71U, TR-71W, TR-71S TR-1106 Fluoropolymer Coated Sensor FEP Cable -60 to 155 C -70 to 180 C Avg. ±0.5 C at -40 to 80 C Avg. ±1.0 C at -60 to -40 C, 80 to 100 C Avg. ±.0 C at 100 to 155 C Approx. 80 sec. ( in air ) Approx. 7 sec. ( in agitated water ) TR FEP Shrink Tube (SUS16) Iersion proof -60 to 155 C -70 to 180 C Avg. ±0.5 C at -40 to 80 C Avg. ±1.0 C at -60 to -40 C, 80 to 100 C Avg. ±.0 C at 100 to 155 C Approx. 150 sec. ( in air ) Approx. 7 sec. ( in agitated water ) (stainless protection tube) Iersion proof (cable) TR FEP Shrink Tube (SUS16) Iersion proof -60 to 155 C -70 to 180 C Avg. ±0.5 C at -40 to 80 C Avg. ±1.0 C at -60 to -40 C, 80 to 100 C Avg. ±.0 C at 100 to 155 C Approx. 150 sec. ( in air ) Approx. 7 sec. ( in agitated water ) (stainless protection tube) Iersion proof (cable) 4

5 TR4, TR-5i, RTR-50 / 50L Discontinued RTR-5/5L/5A/5AL, TR-5, TR-5S, RTR-71 TR-5101 Fluoropolymer Coated Sensor 45 6 Avg. ± 0. C at -0 to 80 C Avg. ± 0.5 C at -40 to -0 C, 80 to 110 C Approx. 80 sec. ( in air ) Cable is waterproof. waterproof Can be extended by meters with the Extension Cable TR-C0 TR-5106 Fluoropolymer Coated Sensor Provided with TR4, TR-5i, RTR-50 and RTR-50L Avg. ± 0. C at -0 to 80 C Avg. ± 0.5 C at -40 to -0 C, 80 to 110 C Approx. 80 sec. ( in air ) Approx. 7 sec. ( in agitated water ) Can be extended by meters with the Extension Cable TR-C0 TR (SUS16).5 4 FEP Shrink Tube Iersion proof Avg. ± 0. C at -0 to 80 C Avg. ± 0.5 C at -40 to -0 C, 80 to 110 C Approx. 150 sec. (in air) Approx. 7 sec. (in agitated water) (stainless protection tube) Iersion proof (cable) Can be extended by meters with the Extension Cable TR-C0 5

6 TR-50 TR4, TR-5i, RTR-50 / 50L Discontinued RTR-5/5A, TR-5, TR-5S, RTR (SUS16).5 4 FEP Shrink Tube Iersion proof Avg. ± 0. C at -0 to 80 C Avg. ± 0.5 C at -40 to -0 C, 80 to 110 C Approx. 90 sec. (in air) Approx. sec. (in agitated water) (stainless protection tube) Iersion proof (cable) Can be extended by meters with the Extension Cable TR-C0 TR (SUS16) FEP Shrink Tube Iersion proof Avg. ± 0. C at -0 to 80 C Avg. ± 0.5 C at -40 to -0 C, 80 to 110 C Approx. 90 sec. (in air) Approx. sec. (in agitated water) (stainless protection tube) Iersion proof (cable) Can be extended by meters with the Extension Cable TR-C0 TR-550 Underwater Sensor Fluoropolymer Mold Protection Tube Max7 (SUS16) Avg. ± 0. C at -0 to 80 C Avg. ± 0.5 C at -40 to -0 C, 80 to 110 C Approx. 150 sec. (in air) Approx. 15 sec. (in agitated water) Can be extended by meters with the Extension Cable TR-C0 6

7 TR4, TR-5i, RTR-50 / 50L Discontinued RTR-5/5A, TR-5, TR-5S, RTR-71 TR-560 High Sensitivity Ultra-thin Sensor (SUS16) FEP ShrinkTube Iersion proof Avg. ± 0.5 C at -0 to 60 C Avg. ± 1.0 C at -60 to -0 C, 60 to 80 C Avg. ±.0 C at 80 to 155 C Approx. 50 sec. (in air) Approx. 1 sec. (in agitated water) (stainless protection tube) Iersion proof (cable) Can be extended by meters with the Extension Cable TR-C0 7

8 TR45, TR-81, TR-55i-Pt, RTR-505-Pt / 505-PtL Discontinued RTR-5Pt / RTR-5PtL Pt Sensors Model Number TR A B C D M To order, create the model number by selecting A, B, C, and D ( See below ). Sensor Type ( digits ) Protection Tube Diameter ( digits ) Protection Tube Length ( 4 digits ) Cable Length ( digits ) Sensor Device Pt100 Range of Error ± ( xt ) C Electrical Current ma t = absolute value of measurement Insulation Resitance DC500V over 10M Waterproof Capacity Conductor wire type None only stainless protection pipe is water resistant Sensor Type (Select from 4 types) TR-8100 Economical Type : -50 to 00 C Thermal Constant Time* : In agitated water: about 4.5 seconds Stainless Protection Tube (SUS16) TR-8110 Regular Type 1.9 : -00 to 50 C Thermal Constant Time * : In agitated water: about seconds m Heat Durability TR-810 Low to High Temp Type : -00 to 600 C Thermal Constant Time * : In agitated water: about seconds Stainless Protection Tube (SUS16) 40 Sleeve SUS04 8 m Protection Tube Diameter Recoended Sensor Type TR-8100 TR-8110 TR-810 TR Protection Tube Length Available - Not Available The protection tube is available in 50 millimeter units in lengths from 50 to 000. Cable Length The sensor cable is available in 1 meter units in lengths from 1 meter to 99 meters. : Our sensors are produced only upon order, therefore please allow four weeks from time of order until shipping. The thermistor (temperature detection section) is mounted in the tip of the sensor Heat Durability TR-810 Handy Type : -50 to 00 C Thermal Constant Time * In agitated water: about.5 seconds Stainless Protection Tube (SUS16) 98 Grip (Bakelite) Heat Durability 0 60 m PVC Cable 50 * Stated thermal constant time is for sensors with a protection tube diameter of.. 8

9 Sensor Extension Cables TR-1C0 Sensor Extension Cable PVC Cable [unit: ] -5 to 60 C Compatible Sensors Conditions for Use None Temperature Sensor: TR-1106, TR-10, TR-10, TR-0106, TR-006, TR-006, TR-0406, TR-0506, TR-0706 Temp-Humidity Sensor: THA-001, THA-151, SHA-151 ( Previous Model HHA-151 ) Illuminance-UV Sensor: ISA-151 Input Cable: VR-7101, VR-710, VR-710 Temperature sensors can use up to meters of extension cables. Temp-Humidity sensors and Illuminance-UV sensors can use up to 9 meters of extension cables. Input cables can use multiple extension cables. TR- Sensor Extension Cable PVC Cable -5 to 60 C None Compatible Sensors Temperature Sensor: TR-1106, TR-10, TR-10, TR-0106, TR-006, TR-006, TR-0406, TR-0506, TR-0706, Temp-Humidity Sensor: THA-001, THA-151, SHA-151, TR-100 * ( Previous Model HHA-151 ) Illuminance-UV Sensor: ISA-151 Conditions for Use Temperature sensors can use up to meters of extension cables. Temp-Humidity sensors and Illuminance-UV sensors can use up to 9 meters of extension cables. * Only 1 extension cable for TR-100 TR-C0 Sensor Extension Cable PVC Cable -5 to 60 C Splash proof ( rated for use in daily life ) Compatible Sensors Temperature Sensor: TR-5101, TR-5106, TR-50, TR-50, TR-540, TR-550, TR-560 Conditions for Use Only one cable per sensor. 9