SafeSite LED High Bay High Efficiency - UL 844. for Indoor and Outdoor Hazardous Applications

Size: px
Start display at page:

Download "SafeSite LED High Bay High Efficiency - UL 844. for Indoor and Outdoor Hazardous Applications"

Transcription

1 SafeSite LED High Bay High Efficiency - UL 844 for Indoor and Outdoor Hazardous Applications

2 On when it matters most. Products and solutions that protect your business *Products shown above are not all certified for hazardous locations. Please visit for more information. 2 Jan2018

3 Features & Benefits 10 year warranty L70 rated for >150, C Up to 125 LPW Low T-Rating compared to traditional fixtures Dual mounting option available Industry best total cost of ownership Significantly reduced glare Instant on/off operation Low maintenance Mercury free No UV or IR Resistant to shock and vibration Application At 125 lumens per Watt, Dialight s new ultra-efficient Class I, Division 2 LED High Bay revolutionizes the world of LED lighting. In a compact and lightweight structure, Dialight s new 125 lumen per watt LED High Bay is designed to meet the most demanding specifications and is perfect for any Class I, Division 2 application where improved lighting levels are needed at minimum energy consumption for more than a decade. Jan2018 3

4 SafeSite Hazardous Applications High Bay Hazardous Locations Ratings Fixed and portable fixtures for installation and use in hazardous (classified) locations Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III, Divisions 1 and 2, in accordance with the National Electrical Code, NFPA 70 Classes The classes define the general nature of hazardous material in the surrounding atmosphere. Class Hazardous Material in Surrounding Atmosphere Class I Hazardous because flammable gases or vapors are present in the air in quantities sufficient to produce explosive or ignitable mixtures. Class II Hazardous because combustible or conductive dusts are present. Class III Hazardous because ignitable fibers or flying s are present, but not likely to be in suspension in sufficient quantities to produce ignitable mixtures. Typical wood chips, cotton, flax and nylon. Group classifications are not applied to this class. Divisions The division defines the probability of hazardous material being present in an ignitable concentration in the surrounding atmosphere. Division Presence of Hazardous Material Division 1 The substance referred to by class is present during normal conditions. Division 2 The substance referred to by class is present only in abnormal conditions, such as a container failure or system breakdown. Groups The group defines the hazardous material in the surrounding atmosphere. Group Hazardous Material in Surrounding Atmosphere Group A Acetylene Group B Hydrogen, fuel and combustible process gases containing more than 30% hydrogen by volume or gases of equivalent hazard such as butadiene, ethylene, oxide, propylene oxide and acrolein. Group C Carbon monoxide, ether, hydrogen sulfide, morphline, cyclopropane, ethyl and ethylene or gases of equivalent hazard. Group D Group E Group F Gasoline, acetone, ammonia, benzene, butane, cyclopropane, ethanol, hexane, methanol, methane, vinyl chloride, natural gas, naphtha, propane or gases of equivalent hazard. Combustible metal dusts, including aluminum, magnesium and their commercial alloys or other combustible dusts whose particle size, abrasiveness and conductivity present similar hazards in connection with electrical equipment. Carbonaceous dusts, carbon black, coal black, charcoal, coal or coke dusts that have more than 8% total entrapped volatiles or dusts that have been sesitized by other material so they present an explosion hazard. Group G Flour dust, grain dust, flour, starch, sugar, wood, plastic and chemicals. Reference: Jan2018

5 Hazardous Applications High Bay SafeSite High Efficiency - Class I Div. 2 Models Certifications & Ratings UL 1598/A UL 844 NEMA 4X IP66 CSA 22.2 No. 137-M81 Class I, Div. 2 Groups A, B, C, D Class II, Div. 2 Groups F, G Class III Mechanical Information: Fixture weight: Shipping weight: Mounting: Cabling: 18 lbs (8 kg) 24 lbs (13 kg) (1) 3/4 NPT - top (2) 5/16-18 x.75 UNC - side 10 (3.05m) STOOW Power Cord 6.88 [174.75] 1.88 [47.75] [406.40] Ambient Temperature Range T4 Temperature Code 1.95 [49.53] 3.00 [76.20] 5/16-18x.75 THREADED (2) Temperature Ratings 10 [3.05m] cord [406.40] Dimensions in inches [mm] Ambient Temperature Range T5 Temperature Code -40 o F to +149 o F (-40 o C to +65 o C) -40 o F to +131 o F (-40 o C to +50 o C) Electrical Specifications: Operating voltage: V AC: 26,000lm models V AC: 18,000, 14,000, 11,000lm models Power consumption: Operating temp: See table Harmonics: IEC F to +149 F (-40 C to +65 C) Noise requirement /EMC: FCC Title 47, Subpart B, Section 15, Class A device. RF Immunity; 10V/m, 80MHz-1GHz Transient protection: THD: < 20% Power factor: > 0.9 Construction: Housing: Protection devices capable of handling up to 6kA. Tested with 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground Copper free aluminum Finish: Lens 1 : Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy primer Tempered glass Photometric Information: CRI: 75 CCT: 5000K (cool white) 4000K (neutral white) All values typical unless otherwise stated (tolerance +/- 10%) 1 For information on chemical compatibility, please follow this link to reference Dialight s Chemical Compatibility Guide: Jan2018 5

6 SafeSite Hazardous Applications High Bay High Efficiency - Class I Div. 1 Models Certifications & Ratings UL 1598/A UL 844 NEMA 4X CSA 22.2 No. 137-M81 Class I, Div. 1 Groups C, D Class II, Div. 2 Groups F, G IP66 Mechanical Information: Fixture weight: Shipping weight: Mounting: Cabling: 30 lbs (14 kg) 35 lbs (19 kg) (1) 3/4 NPT - top (2) 5/16-18 x.75 UNC - side 10 (3.05m) STOOW Power Cord Ambient Temperature Range T4 Temperature Code Temperature Ratings Dimensions in inches [mm] Ambient Temperature Range T5 Temperature Code -40 o F to +149 o F (-40 o C to +65 o C) -40 o F to +122 o F (-40 o C to +50 o C) Electrical Specifications: Operating voltage: V AC: 23,500lm models V AC: 16,000, 12,500, 9,650lm models Power consumption: Operating temp: See table Harmonics: IEC F to +149 F (-40 C to +65 C) Noise requirement /EMC: FCC Title 47, Subpart B, Section 15, Class A device. RF Immunity; 10V/m, 80MHz-1GHz Transient protection: THD: < 20% Power factor: > 0.9 Construction: Housing: Protection devices capable of handling up to 6kA. Tested with 6kV/2 ohm combination wave, as per IEEE C62.41, line-line and line-ground Copper free aluminum Finish: Lens 1 : Superior dual coat finish - Sealed polyester topcoat - Chemical-resistant epoxy primer Tempered glass Photometric Information: CRI: 75 CCT: 5000K (cool white) 4000K (neutral white) All values typical unless otherwise stated (tolerance +/- 10%) 1 For information on chemical compatibility, please follow this link to reference Dialight s Chemical Compatibility Guide: Jan2018

7 Hazardous Applications High Bay Mounting Accessories and Dimensions SafeSite Classifications: CID1 CID2 HBXW1 Wall mount Classifications: CID2 HBXW2 Swivel bracket and cable gland Classifications: CID2 HBXCG Cable gland Classifications: CID2 HBX-DUAL-BRCKT Dual bracket Classifications: CID1 CID2 HBXC1 Ceiling mount Classifications: CID1 CID2 HBXW3-SSL-316 Stainless steel swivel bracket 316 Stainless steel HBXW3-SSL-304 Stainless steel swivel bracket 304 Stainless steel Jan2018 7

8 SafeSite Hazardous Applications High Bay Mounting Accessories Dimensions HBXW1 - Wall mount HBXW2 - Swivel bracket and cable gland [285.24] [307.09] [406.40] 4.06 [103.12] HBXCU - Ceiling mount HBXW3-SSL-xxx - Stainless steel bracket 8 Jan2018

9 Hazardous Applications High Bay Light Distribution Pattern SafeSite Medium Pattern Max plane at H = 45 Max cone at V = 30 MAX CANDLEPOWER: Wide Pattern Jan2018 9

10 SafeSite Hazardous Applications High Bay Class I Div 1 / Class II Div 1 models - Ordering Information Classifications: CID1 C, D CID2 Groups A, B, C, D CIID1 E, F, G CIID2 F, G CIII Part Number CID1 CID2 CIID1 CIID2 CIII Voltage Lens CID2 Models Safety bracket CCT Fixture Lumens Watt LPW Optical Pattern HEDGMC4PN-SSG V AC Tempered glass 5000K (cool white) 26, Circular HEDGMC4PN-SNG V AC Tempered glass 5000K (cool white) 26, Circular HEDGRC4PN-SSG V AC Tempered glass 5000K (cool white) 26, Wide HEDGRC4PN-SNG V AC Tempered glass 5000K (cool white) 26, Wide HEDGMC4KN-SSG V AC Tempered glass 5000K (cool white) 18, Circular HEDGMC4KN-SNG V AC Tempered glass 5000K (cool white) 18, Circular HEDGRC4KN-SSG V AC Tempered glass 5000K (cool white) 18, Wide HEDGRC4KN-SNG V AC Tempered glass 5000K (cool white) 18, Wide HEDGMC4GN-SSG V AC Tempered glass 5000K (cool white) 14, Circular HEDGMC4GN-SNG V AC Tempered glass 5000K (cool white) 14, Circular HEDGRC4GN-SSG V AC Tempered glass 5000K (cool white) 14, Wide HEDGRC4GN-SNG V AC Tempered glass 5000K (cool white) 14, Wide HEDGMC4DN-SSG V AC Tempered glass 5000K (cool white) 11, Circular HEDGMC4DN-SNG V AC Tempered glass 5000K (cool white) 11, Circular HEDGRC4DN-SSG V AC Tempered glass 5000K (cool white) 11, Wide HEDGRC4DN-SNG V AC Tempered glass 5000K (cool white) 11, Wide All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%). 1 All models shown in the table are Cool White, for models in Neutral 4000K CCT replace the 6th character with an N. Example: HEDGMC4PN-SNG becomes HEDGMN4PN-SNG. Deduct 7% from lumen values when specifying neutral. 2 Part numbers listed in the tables above come with a glass lens. For models needing a flat polycarbonate lens, replace the 4th character with a 2, Ex: HEDGMN4GN-SNG becomes HED2MN4GN-SNG. Deduct 3% from lumens for the lens change. Part Number CID1 CID2 CIID1 CIID2 CIII Voltage Lens CID2 / CIID1 Models Safety bracket CCT Fixture Lumens Watt LPW Optical Pattern HEF2MC4PN-SNG V AC Clear Polycarbonate 5000K (cool white) 22, Circular HEF2MC4PN-SSG V AC Clear Polycarbonate 5000K (cool white) 22, Circular HEF2MC4KN-SNG V AC Clear Polycarbonate 5000K (cool white) 14, Circular HEF2MC4KN-SSG V AC Clear Polycarbonate 5000K (cool white) 14, Circular HEF2MC4GN-SNG V AC Clear Polycarbonate 5000K (cool white) 11, Circular HEF2MC4GN-SSG V AC Clear Polycarbonate 5000K (cool white) 11, Circular HEF2MC4DN-SNG V AC Clear Polycarbonate 5000K (cool white) 9, Circular HEF2MC4DN-SSG V AC Clear Polycarbonate 5000K (cool white) 9, Circular All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%). 1 All models shown in the table are Cool White, for models in Neutral 4000K CCT replace the 6th character with an N. Example: HEF2MC4PN-SNG becomes HEF2MN4PN-SNG. Deduct 7% from lumen values when specifying neutral Jan2018

11 Hazardous Applications High Bay Class I, Div 1 - Ordering Information Classifications: CID1 C, D CIID2 F, G Part Number CID1 CID2 CIID1 CIID2 CIII Voltage Lens All values typical unless otherwise stated, Lumen values are typical (tolerance +/- 10%). 1 All models shown in the table are Cool White, for models in Neutral 4000K CCT replace the 5th character with an N. Example: HEC9MC4PN-SNG becomes HEC9MN4PN-SNG. Deduct 7% from lumen values when specifying neutral. CID1 Models Safety bracket CCT Fixture Lumens SafeSite Watt LPW Optical Pattern HEC9MC4PN-SNG V AC Tempered glass 5000K (cool white) 23, Circular HEC9MC4PN-SSG V AC Tempered glass 5000K (cool white) 23, Circular HEC9RC4PN-SNG V AC Tempered glass 5000K (cool white) 22, Wide HEC9RC4PN-SSG V AC Tempered glass 5000K (cool white) 22, Wide HEC9MC4KN-SNG V AC Tempered glass 5000K (cool white) 16, Circular HEC9MC4KN-SSG V AC Tempered glass 5000K (cool white) 16, Circular HEC9RC4KN-SNG V AC Tempered glass 5000K (cool white) 15, Wide HEC9RC4KN-SSG V AC Tempered glass 5000K (cool white) 15, Wide HEC9MC4GN-SNG V AC Tempered glass 5000K (cool white) 12, Circular HEC9MC4GN-SSG V AC Tempered glass 5000K (cool white) 12, Circular HEC9RC4GN-SNG V AC Tempered glass 5000K (cool white) 11, Wide HEC9RC4GN-SSG V AC Tempered glass 5000K (cool white) 11, Wide HEC9MC4DN-SNG V AC Tempered glass 5000K (cool white) 9, Circular HEC9MC4DN-SSG V AC Tempered glass 5000K (cool white) 9, Circular HEC9RC4DN-SNG V AC Tempered glass 5000K (cool white) 9, Wide HEC9RC4DN-SSG V AC Tempered glass 5000K (cool white) 9, Wide CID1 Models - Paint Spray Rated HEM9RC4PN-SNG V AC Tempered glass 5000K (cool white) 23, Wide HEM9RC4PN-SSG V AC Tempered glass 5000K (cool white) 23, Wide HEM9NC4PN-SNG V AC Tempered glass 5000K (cool white) 23, Narrow HEM9NC4PN-SSG V AC Tempered glass 5000K (cool white) 23, Narrow HEM9MC4PN-SNG V AC Tempered glass 5000K (cool white) 23, Circular HEM9MC4PN-SSG V AC Tempered glass 5000K (cool white) 23, Circular HEM9NC4KN-SNG V AC Tempered glass 5000K (cool white) 17, Narrow HEM9NC4KN-SSG V AC Tempered glass 5000K (cool white) 17, Narrow HEM9MC4KN-SNG V AC Tempered glass 5000K (cool white) 16, Circular HEM9MC4KN-SSG V AC Tempered glass 5000K (cool white) 16, Circular HEM9RC4KN-SNG V AC Tempered glass 5000K (cool white) 16, Wide HEM9RC4KN-SSG V AC Tempered glass 5000K (cool white) 15, Wide HEM9NC4GN-SNG V AC Tempered glass 5000K (cool white) 13, Narrow HEM9NC4GN-SSG V AC Tempered glass 5000K (cool white) 13, Narrow HEM9RC4GN-SNG V AC Tempered glass 5000K (cool white) 12, Wide HEM9RC4GN-SSG V AC Tempered glass 5000K (cool white) 12, Wide HEM9MC4GN-SNG V AC Tempered glass 5000K (cool white) 12, Circular HEM9MC4GN-SSG V AC Tempered glass 5000K (cool white) 12, Circular HEM9NC4DNSNG V AC Tempered glass 5000K (cool white) 10, Narrow HEM9NC4DNSSG V AC Tempered glass 5000K (cool white) 10, Narrow HEM9MC4DN-SNG V AC Tempered glass 5000K (cool white) 9, Circular HEM9MC4DN-SSG V AC Tempered glass 5000K (cool white) 9, Circular HEM9RC4DN-SNG V AC Tempered glass 5000K (cool white) 9, Wide HEM9RC4DN-SSG V AC Tempered glass 5000K (cool white) 9, Wide Jan

12 North American HQ 1501 Route 34 South Farmingdale, NJ Tel: Fax: EMEA Technical Centre Ejby Industrivej 91 B 200 Glostrup Tel: (Denmark) Tel: (UK) Tel: (Germany) Tel: (France) sales-europe@dialight.com Houston Barker Springs Rd Ste 407 Houston, TX Tel: Faz: info@dialight.com Australia 38 O'Malley Street Osborne Park, WA 6017 Tel: +61 (0) Fax: +61 (0) info@dialight.com.au Southeast Asia 33 Ubi Avenue 3 #07-72 Vertex (Tower A) Singapore Tel: Fax: enquiry@dialight.com.sg Brazil Alameda Mercurio, 225 American Park Empresarial NR Indaiatuba SP Tel: +55 (19) Fax: +55 (19) brasil@dialight.com Middle East Level 42 Emirates Towers (Office Tower) Sheikh Zayed Road Dubai, United Arab Emirates Fax: +971 (0) Tel: +971 (0) ALL VALUES ARE DESIGN OR TYPICAL VALUES WHEN MEASURED UNDER LABORATORY CONDITIONS. THE LIGHTING EFFICIENCY STATEMENTS CONTAINED HEREIN ARE CALCULATED ON A LUMEN PER WATTS BASIS WHEN COMPARING FIXTURES WITH SIMILAR FEATURES. ALL INFORMATION PROVIDED IS ACCURATE AS OF THE DATE OF PUBLICATION, IS SUBJECT TO CHANGE WITHOUT NOTICE AND DOES NOT FORM PART OF ANY CONTRACT WITH DIALIGHT. DIALIGHT DOES NOT WARRANT OR REPRESENT THAT ITS PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE AND HAS NO RESPONSIBILITY FOR THE [INAPPROPRIATE/UNAUTHORISED/NON-APPROVED] USE OF ANY DIALIGHT PRODUCTS BY THE END USER. Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document will always be available at: