1 CERTIFICATE OF PRODUCT CONFORMITY Dubai Central Laboratory Department (DCLD) of Dubai Municipality, hereby attests that the product(s) PIPE AND DUCT INSULATION PRODUCTS (GLASSWOOL) (Details as per the attached Scope of Certification) manufactured by: KUWAIT INSULATING MATERIALS MANUFACTURING CO. P.O. Box: Shuaiba, Kuwait have been assessed in accordance with DCLD Document Ref. No. DM-DCLD-RD-DP (IC) General Rules for DM third party product certification system through factory assessment and the relevant Specific Rules, and were found in conformity with the standard specification: 2017 Al Sa fat Dubai Green Building Evaluation System Accordingly, DCLD hereby authorizes the above manufacturer to affix the DCL Product Conformity Mark to the above-mentioned product(s). Verify: for / ENGR. AMIN AHMED AMIN Director, Dubai Central Laboratory Department Dubai Municipality Certificate No: CL Current Issue Date: 25 June 2018 Valid Until: 24 June 2019 Original Issue Date: 25 June 2018 The attached Scope of Certification bearing the same Certificate No. forms an integral part of this Certificate. This Certificate is an electronic document, subject to the Terms and Conditions of the Product Certification System and shall not be reproduced except in full. DM-DCLD-F-IC-2031 REV 13

2 Certificate Issued To: KUWAIT INSULATING MATERIALS MFG. CO. P.O. Box: Shuaiba, Kuwait Applicable Standard Specification: 2017 Al Sa fat Dubai Green Building Evaluation System Applicable Specific Rules: RD-DP (IC) Specific Rules for Certification of Pipe and Duct through Factory Assessment as per Al Sa fat Dubai Green Building Evaluation System S/N Product Description Product Brand Product Details Duct without facing 1 2 Wool) Duct Board Duct (KDI) Nominal Density, kg/m³ Duct with aluminum foil facing Nominal Density, kg/m³ Duct without facing 3 Nominal Density, kg/m³ (CFC Free) NOTE 5 EcoBuild Duct Duct with aluminum foil facing (EDI) Nominal Density, kg/m³ 4 Page 1 of 5

3 Duct Liner with black woven glass fabric k-value: W/(m K) 5 6 Clean Liner (KCL) Duct System (KADS) Nominal Density, kg/m³ Nominal Thickness, mm the maximum requirement for Flame Spread Index =15 and Duct with aluglass and aluminum foil facing k-value: W/(m K) Nominal Density, kg/m³ Nominal Thickness, mm Pre-insulated Duct Board with reinforced aluminum one side and black glass cloth other side Wool) Duct Board 7 CLIMAVER NETO k-value: W/( m K) Nominal Density, kg/m³ Nominal Thickness, mm Smoke Developed Index = 5 for 25mm NOTE 4 Pre-insulated Duct Board with reinforced aluminum foil both side facing (CFC Free) NOTE 5 8 CLIMAVER PLUS R k-value: W/( m K) Nominal Density, kg/m³ Nominal Thickness, mm the maximum requirement for Flame Spread Index =5 and Smoke Developed Index = 25 for 25mm NOTE 4 Duct without facing 1 2 Wool) Duct Blanket Duct (KDI) Duct without facing Page 2 of 5

4 Wool) Duct Blanket Duct (KDI) EcoBuild Duct (EDI) Duct with aluminum foil facing the maximum requirement for Flame Spread Index =5 and Smoke Developed Index = 10 for 75mm NOTE 4 Duct with aluminum foil facing the maximum requirement for Flame Spread Index =5 and Smoke Developed Index = 10 for 75mm NOTE 4 Duct without facing Duct without facing Duct with aluminium foil facing Page 3 of 5

5 8 9 Wool) Duct Blanket EcoBuild Duct (EDI) Ecobuild Clean Liner (ECL) Duct with aluminum foil facing Duct with black woven glass fabric k-value: W/(m.K) Nominal Density, kg/m³ Nominal Thickness, mm without facing k-value: W/(m.K) 1 Nominal Density, kg/m³ Nominal Thickness, mm Nominal Diameter, mm with aluminum foil facing k-value: W/(m.K) 2 Wool) Pipe Rigid Pipe Covering (K450) Nominal Density, kg/m³ Nominal Thickness, mm Nominal Diameter, mm the maximum requirement for Flame Spread Index = 25 and Smoke Developed Index = 50 for 25mm NOTE 4 with Aluglass facing k-value: W/(m.K) 3 Nominal Density, kg/m³ Nominal Thickness, mm Nominal Diameter, mm Note 1: This document forms part of the Certificate of Product Conformity bearing the same certificate number. Note 2: The above products shall bear the DCL Conformity Mark (applied on each product or on the packaging). Note 3: Maximum k-value measured at 35ºC temperature and 60% relative humidity condition Note 4: Fire Performance Properties comply with UAE Fire & Life Safety Code 2017 Note 5: In compliance with Clause (1) of the Al Sa fat Dubai Green Building Evaluation System. Page 4 of 5

6 Original Issue Date : 25 JUNE 2018 Current Issue Date : 25 JUNE 2018 Valid Until : 24 JUNE 2019 ARIF HUSSAIN AL MARZOOQI Head, Products Conformity Assessment Section Dubai Central Laboratory Department Page 5 of 5