SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Size: px
Start display at page:

Download "SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005"

Transcription

1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 KAMAX - L.P West Long Lake Road Troy, MI Mr. Joe Peruski Phone: Joe.Peruski@kamax.com MECHANICAL Valid until: April 30, 2018 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory at the location listed above as well as the satellite laboratory location listed below to perform the following tests on fasteners, metals and alloys: Test Technology: Hardness (Rockwell B, C, 15N) ASTM E18, F606, F606M; ISO 898 1; SAE J1199 (Vickers 10kg, 30kg) ASTM E384; ISO Microhardness (Knoop, 500g) (Vickers, 300g to 500g) ASTM E384 Tensile (Axial, Wedge; 0 lbs to 90,000 lbs) ASTM A370, F606, F606M; ISO 898 1; SAE J1199 Proof (Externally Threaded Fasteners) ASTM A370, F606, F606M; ISO 898 1; SAE J1216, J1199 Hydrogen Embrittlement ASTM F606, F606M; Daimler Chrysler PS 9500; SAE J238, J773; SAE/USCAR 7 Torsional Strength ASTM F738, F606, F606M; ISO Ductility (Bend) SAE J78, J81; ISO Environmental Simulation (Salt Fog) SAE/USCAR 1; ASTM B117 Plating Thickness (Optical) ASTM B487; ISO 1463 Plating Thickness (Coating Weight) ASTM B767 (A2LA Cert. No ) 08/08/2016 Page 1 of 4

2 Test Technology: Torque Tension IFI 101; SAE J174, J174M; SAE/USCAR 10, 11; DIN 946; ISO Drive Testing ASME/ANSI B18.6.4; SAE J81, J1237 Break Away/Prevailing Torque IFI 124, 125 Surface Texture ASME/ANSI B46.1 Metallographic Evaluation: Microstructure QLTY 5367 Discontinuities ASTM E340, F788; ISO ; ISO ; SAE J123, J1061 Depth of Decarburization ASTM E1077; F2328 ISO 898 1, 898 5; SAE J121M, J419 Grain Flow Case Depth ASTM E340; SAE/USCAR 8 SAE J423 I. Dimensional Testing 2 Parameter/ Equipment Range CMC 3 (±) Comments External Threads 4 Pitch Diameter, single in Single tri rolls Pitch Diameter, functional in Segment gages Length 4 (1D) Up to 12 in in Caliper Up to 1 in in Micrometer Up to 10 in in Up to 1 in in V anvil micrometer Angle 4 Up to Up to Contour reader (A2LA Cert. No ) 08/08/2016 Page 2 of 4

3 Parameter/ Equipment Range CMC 3 (±) Comments Radius 4 (0.005 to 8) in in (0.005 to 2) in in Contour reader Recesses (depth) 4 Up to 0.5 in in Penetration gage with indicator Straightness 4 Up to 2 in in Gage fixture Thread Runout in Tri-roll & indicator Parameter/Equipment Range Comments Internal Threads 4 Pitch Diameter Minor Diameter (0.025 to 0.75) in Go/No Go plug gage Gage pins 1 This accreditation covers testing performed at the main laboratory listed above, and testing performed at the satellite laboratory identified below. 2 This laboratory does not offer commercial dimensional testing. 3 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine measurements of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific measurement performed by the laboratory may be greater than the CMC due to the behavior of the customer s device and to influences from the circumstances of the specific measurement. 4 This test is not equivalent to that of a calibration. (A2LA Cert. No ) 08/08/2016 Page 3 of 4

4 KAMAX - L.P Roods Lake Rd Lapeer, MI Test Technology: Hardness Vickers (10kg, 30kg) ASTM E384; ISO Rockwell (C, 15N) ASTM E18, F606, F606M; ISO 898-1; SAE J1199 Microhardness (Vickers, 300g, 500g) ASTM E384; ISO Tensile (Axial, Wedge; 0 lbs to 90,000 lbs) ASTM A370, F606, F606M; ISO 898 1; SAE J1199 Metallographic Evaluation: Microstructure QLTY 5367 Discontinuities ASTM E340, F788; ISO ; ISO ; SAE J123, J1061 Depth of Decarburization ASTM E1077; F2328; ISO 898 1, 898 5; SAE J121M, J419 Grain Flow SAE/USCAR 8 (A2LA Cert. No ) 08/08/2016 Page 4 of 4

5 Accredited Laboratory A2LA has accredited KAMAX - L.P. Troy, MI for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 8 th day of August Senior Director of Quality and Communications For the Accreditation Council Certificate Number Valid to April 30, 2018 For the tests to which this accreditation applies, please refer to the laboratory s Mechanical Scope of Accreditation.