Hempaline Defend 400 (Cure 72)

Size: px
Start display at page:

Download "Hempaline Defend 400 (Cure 72)"

Transcription

1 Defend 400 (Cure 72) Defend 400 part A White 9780S Hempel Cure 72 part B Blue Hempel Solvent Clear Storage facility for pre-conditioning of material prior Defend 400 parts A and B should be stored that the materials are maintained at a temperature of below 77 F (25 C )at all stages after delivery of the material to assist with application. Ensure that part A is thoroughly mixed until uniform (and to confirm no hard settlement) before adding the stirrer - avoiding over mixing which may introduce heat. working pot-life. equipment, hoses, lines or gun. Flush immediately after use, or in the event of any prolonged stoppages, with Hempel Solvent Solvent Always use fresh drums - do not top-up existing cans

2 Oil and Gas Defend part A Grey 9580A 500 part B White Hempel Solvent Clear, Airless spray tips thou ( mm) Storage facility for pre- conditioning of material prior 500 parts A and B should be stored in a clean dry location before use. It is recommended that the materials are cooled to maintain a temperature of below 68 F (20 C) at all stages after delivery of the material. Ensure that parts A is thoroughly mixed until uniform (and to confirm no gelation) before adding the peroxide stirrer avoiding over mixing which may introduce heat. working pot- life 500 has a short pot- life after mixing. equipment, hoses, lines or gun. Flush immediately after use, or in the event of any prolonged stoppages, with Hempel Solvent for any wear or damage replace as required. Solvent It is recommended that spray equipment is periodically flushed using Hempel Solvent or MEK, after every 4-5 units (60-80 liters), to reduce the risk of overheating and gelation of mixed material. Always use fresh drums do not top- up existing cans V1_JUL_17

3 Defend 630 (Cure 24) Defend 630 part A White 9780F Hempel Cure 24 part B Blue Hempel Solvent Clear Heated plural component airless spray capable of accurately applying material at 3:1 volume ratio In-line and gun filters (60 mesh) Storage facility for pre-conditioning of material prior 2 x 25.4 cm (10 ) in-line stainless steel static mixers should be used (before the whip-end) to ensure efficient blending of parts A and B. It is recommended to recirculate (under agitation) the material in the day tanks to achieve and maintain optimum temperature throughout the system. It is recommended that a ratio check is carried out before application commences to confirm the equipment is delivering the materials correctly. Defend 630 parts A and B should be stored that the materials are heated to achieve F (35-40 C) before use (to ease mixing and loading into equipment). Ensure that both parts A and B are thoroughly mixed before loading into the appropriate hoppers of the plural component airless spray equipment. At the end of a spray session or in the event of any blockages/delays fully flush the spray lines using Hempel Cleaner or approved alternative. Hopper Description Code Defend part A Hempel Cure 24 part B 9780F Fluid pressures (adjust to suit spray) psi, ( MPa) , ( MPa) Temperature recommendations Day tank Hose C ( F) Temperature Manifold C ( F) not to exceed 45 C (113 F)

4 Defend 630 (Cure 72) Defend 630 part A White 9780S Hempel Cure 72 part B Blue Hempel Solvent Clear Storage facility for pre-conditioning of material prior Defend 630 parts A and B should be stored that the materials are maintained at a temperature of below 77 F (25 C) at all stages after delivery of the material to assist with application. Ensure that part A is thoroughly mixed until uniform (and to confirm no hard settlement) before adding the stirrer - avoiding over mixing which may introduce heat. working pot-life. equipment, hoses, lines or gun. Flush immediately after use, or in the event of any prolonged stoppages, with Hempel Solvent equipment, hoses, lines or gun. Flush immediately after use, or in the event of any prolonged stoppages, with Hempel Solvent Always use fresh drums - do not top-up existing cans

5 Defend 640 (Cure 24) Defend 640 part A White 9780F Hempel Cure 24 part B Blue Hempel Solvent Clear Heated plural component airless spray capable of accurately applying material at 3:1 volume ratio In-line and gun filters (60 mesh) Storage facility for pre-conditioning of material prior 2 x 25.4 cm (10 ) in-line stainless steel static mixers should be used (before the whip-end) to ensure efficient blending of parts A and B. It is recommended to recirculate (under agitation) the material in the day tanks to achieve and maintain optimum temperature throughout the system. It is recommended that a ratio check is carried out before application commences to confirm the equipment is delivering the materials correctly. Defend 640 parts A and B should be stored that the materials are heated to achieve F (35-40 C) before use (to ease mixing and loading into equipment). Ensure that both parts A and B are thoroughly mixed before loading into the appropriate hoppers of the plural component airless spray equipment. At the end of a spray session or in the event of any blockages/delays fully flush the spray lines using Hempel Cleaner or approved alternative. Hopper Description Code Defend 640 part A Hempel Cure 24 part B 9780F Fluid pressures (adjust to suit spray) psi, ( MPa) , ( MPa) Temperature recommendations Day tank Hose F (40-45 C) Temperature Manifold F (35-40 C) not to exceed 113 F (45 C)

6 Oil and Gas Defend A5 Defend 645 part A White 923AM Defend 645 part B Blue Hempel Solvent Clear (>5000 psi / 34.5 MPa) such as Graco XTR 7 ü ü Storage facility for pre-conditioning of material prior Defend 645 parts A and B should be stored that the materials are cooled to maintain a temperature of below 68 F (20 C) at all stages after delivery of the material. Ensure that part A is thoroughly mixed until uniform (and to confirm no gelation) before adding the peroxide stirrer avoiding over mixing which may introduce heat. working pot-life. equipment, hoses, lines or gun. Flush immediately after use, or in the event of any prolonged stoppages, with Hempel Solvent use for any wear or damage replace as required. Solvent Always use fresh drums do not top-up existing cans V1_JUL_17

7 Oil and Gas Defend part A Grey 9580A 740 part B White Hempel Solvent Clear, Airless spray tips thou ( mm) Storage facility for pre- conditioning of material prior 500 parts A and B should be stored in a clean dry location before use. It is recommended that the materials are cooled to maintain a temperature of below 68 F (20 C) at all stages after delivery of the material. Ensure that part A is thoroughly mixed until uniform (and to confirm no gelation) before adding the peroxide curing agent. Mix thoroughly using efficient mechanical stirrer avoiding over mixing which may introduce heat. working pot- life 500 has a short pot- life after mixing. equipment, hoses, lines or gun. Flush immediately after use, or in the event of any prolonged stoppages, with Hempel Solvent for any wear or damage replace as required. Solvent It is recommended that spray equipment is periodically flushed using Hempel Solvent or MEK, after every 4-5 units (60-80 liters), to reduce the risk of overheating and gelation of mixed material. Always use fresh drums do not top- up existing cans V1_JUL_17