DN 70 Vers. a DN X Vers. b X X X Vers. a = no thermal insulation, Vers. b = with thermal insulation

Similar documents
H series. for upper balconies DN 100. DN 100 Vers. a X X. Partial unit Side drain

Installation instructions. LORO-ATTIKASTAR siphonic drains

Installation instructions LORO-DRAINJET. siphonic scupper drainage system with clamping flange, without roof penetration

COSMOFIN FG Welding Guidelines

CI/SfB Oct 12 (52.5) Uniclass L7314

CI/SfB Oct 12 (52.5) Uniclass L7314

F Ü R D I E ZU K U N FT G E DAC HT. Flat roof vents. Soil vent pipes Refurbishment vents Cold roof vents

Installation Instructions ALUTRIX 600 ALUTRIX FR

PSI Compakt Seals and Wall Sleeves with Fixed / Loose Flange

Contents. Rhepanol. Rhepanol fk with welding edge. Service

MHST 20 lifting/sliding door threshold

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Shower Tray - Timber Floors

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

ACO Marine. ACO Scuppers - ACO Channels ACO Drainage Systems for Shipbuilding and Offshore Installations

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

SECTION 07530CP EPDM MEMBRANE ROOFING

LUX ELEMENTS -TUB shower base elements

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

ESSERGULLY. Safe conventional drainage. Gully systems for flat roofs, balconies and terraces

J41 Reinforced bitumen membrane roof coverings

EVALON Waterproofing Membranes Installation Manual

Installation Guidelines INOFIN FR

Sarnavap 5000E SA Vapour Control Layer

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

SRP-AirOutshield UV Issued:

DRAINAGE GUTTERS FOR DRAIN ASPHALT 2012 TECHNICAL CATALOGUE

SECTION STORM DRAINAGE PIPING SPECIALTIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

BUILT-UP REINFORCED BITUMEN MEMBRANE WARM DECK ROOF COVERING Two layer, EXCEL/SPOT fully adhered waterproofing system

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

LUX ELEMENTS -TUB-BOL shower base elements

Cold Work Cladding Fabrication & Application

Taking drainage to the next level. FDT VarioGully

Self Adhesive EPDM TRAINING MANUAL

1 PVC or ABS drain with strainer

Pipe to Manhole Connectors, Sealants. Pipe to Manhole Connectors, Sealants

A Complete Siphonic Roof Drainage System

Parabond 600 Elastic glue and adhesive with extremely high initial bonding

External drainage. Roof, yard and car park drains. Drainage by design!

PEKAY T570 RUBBERSEAL

Advantix bathroom drain. Instructions for Use from 01/2008. en_int

Can it be more simple?

RhinoBond Induction Fixing System

Testing. Test drainage products according to the applicable AASHTO or ASTM specification, except as otherwise noted.

CI/SfB (52.5) January 2004 Uniclass L L2123. ACO LightShaft Daylight and fresh air. Naturally.

GUARANTEED ASPHALT LIMITED

SECTION MANUFACTURED ROOF EXPANSION JOINTS

J41 Reinforced bitumen membrane roof coverings

EVALASTIC Waterproofing Membranes Installation Manual

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Kingspan Day-Lite Klick

INSTALLATION INSTRUCTIONS KÖSTER TPO

The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

INSTALLATION GUIDE DUOFUSE DECKING

Bridge Drainage Systems

Parabond 600 Elastic adhesive sealant with high initial bonding strength.

INSTRUCTION FOR BONDING TECHNOLOGY Fibermarine / Fibermarine HighLine

Assembly Instruction wedi Fundo Floor element

SELF-ADHESIVE MEMBRANES

Members of the ESSMANN GROUP.

The subfloor roof foil, felt, sealing foil or bituminous sheeting

SECTION BUILT-UP BITUMINOUS WATERPROOFING

SANITARY WASTE AND VENT PIPING

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Aluminium Floor Outlets - Materials Care, Maintenance, Installation & Specifying/Ordering

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Textura Façade panel Product information sheet 1

TOTAL FLOW Soil Sheet Drain

Pipe Flashing Systems

adjustable fusion shower pan surface mounted on subfloor installation guide

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

SECTION ROOF EDGE SAFETY RAILING SYSTEM

adjustable fusion shower pan on wood joists installation guide

INOFIN FPO roofing membrane

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Installation Guidelines for WOLFIN M. Installation Guidelines for WOLFIN M Synthetic Roofing and Waterproofing Membrane

Eco-Grip Flooring Installation Manual Version: 2018

INSTALLATION GUIDELINE. Hertalan EPDM roofing and DPC systems

Technical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:

Eco-Grip Flooring Installation Manual Version: 2018/12

Original Scandinavian rainwater system

fermacell Powerpanel H 2 O Linear Shower Outlet 2.0

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.

Membranes for horizontal external constructions

Piping Accessories TCC-1. TCC-3 Pipe Penetration System. Pipe Penetration System TCC-5. Pipe Penetration System

SECTION STORM DRAINAGE

SECTION PRE-ENGINEERED BUILDING INSULATION

GUIDE TO DUKKABOARD AQUA 77

Trex Commercial Products page Metal Railing

According German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION PLUMBING PIPING SYSTEM

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.

Transcription:

instructions LORO balcony drains, with connecting collar, series E and F according to EN 123, made of hot-dip galvanized steel with additional coating, and System overview Series E drainage in one level, underneath the slab covering one-piece two-piece Vers. a 1271.00X 1271.070X 1471.00X 1471.070X 1281.00X 1281.070X 1481.00X 1481.070X Vers. b 1371.00X 1371.070X 171.00X 171.070X 1381.00X 1381.070X 181.00X 181.070X Vers. a = no thermal insulation, Vers. b = with thermal insulation Series F Drainage in one level, above the slab covering, with additional percolating water drainage or drainage in two levels above and below the slab covering one-piece two-piece Vers. a 1272.00X 1272.070X 1472.00X 1472.070X 1282.00X 1282.070X 1482.00X 1482.070X Vers. b 1372.00X 1372.070X 172.00X 172.070X 1382.00X 1382.070X 182.00X 182.070X Vers. a = no thermal insulation, Vers. b = with thermal insulation Trace heating After checking the roof drains and pipes in areas endangered by frost, we recommend that customers install trace heating if necessary (see EN 1206, Part 1, or DIN 1986, Part 100). Connecting collars for flat roof drainage systems available in: No. 193X Resitrix Bitumen/EPDM compound - Standard No. 1008X Novotan EPDM No. 196X Rhenofol PVC No. 1009X Hertalan EPDM No. 117X Extrubit ECB No. 1011X Trocal S PVC No. 100X Evalon EVA No. 1012X Alkorplan PVC No. 1006X Wolfin IB PVC-BV Unless otherwise specified by the ordering party, a connecting collar of bitumen/epdm compound will be supplied. If sealing sheet already present on-site (without woven or non-woven fabric inlay) is to be clamped, please discuss the application options beforehand with LOROWERK. VL LBE EF S 1 1

Construction diagram Series F Series E Strainer unit No. 1081X Strainer unit No. 1080X Extension unit No. 1204X one-piece two-piece Base unit Vertical drain, without thermal insulation, no. 1200X with thermal insulation, no. 1300X Base unit Lateral outlet, without thermal insulation, no. 1400X with thermal insulation, no. 100X 1.) Connection of LORO connecting collar with balcony sealing sheets The connecting collar of LORO balcony drainages, series E and F, consists of bitumen/epdm compound, PVC or ECB. Please ask at the LOROWERK factory if you require connecting collars for sealing sheets other than those described below. a) Combination connecting collar made of polymer-bitumen/epdm compound for joining to two-layer bituminous sealing sheets. The combination connecting collar 00 x 3.0 mm is a sealing sheet based on EPDM (synthetic rubber). It also contains glass fibre fabric. Manufacturer: Phoenix, type Resitrix. The combination connecting collar is joined to the sealing sheet using hot bitumen (in the hot bitumen gluing or the hot bitumen welding process). 2 VL LBE EF S 2

1 One-piece version: 1 Insert the drain pot in the slab cut-out and cast-in firmly in concrete. The flange should be mounted into the substrate flush with the surface and as neatly as possible. Seal slab cut-out. Cut-out measurements, see page 6. In order to protect the connecting collar during the building phase prior to the execution of sealing work, it is folded up in the factory and protected by a film. In order to process the connecting collar without problems after having carried out the cast in work, the collar must be unfolded. If the sealing work is delayed, precautions must be taken to protect the connecting collar against damage. 2 2 Make holes in the lower sealing sheet and roll it out over the drain. Hole measurements: approx. 230 mm. Note: the flange must remain clear! Thoroughly clean all the contact surfaces (they must be free from grease and dust), and if there is a protective foil on the LORO connecting collar, remove it. 3 3 Apply bituminous adhesive (hot bitumen) to the sealing sheet in the area of the contact surface, or liquefy the bituminous material on the lower sealing sheet by heating it. Make sure when using hot-bitumen gluing, that extreme heating (e.g. use a torch to dry the substrate) is not applied to the lower side of the connecting collar. 4 4 Spread the connecting collar in the liquid hot bitumen (in the hot bitumen gluing process) or in the liquid bituminous material of the bitumen welding sheet (welding process), and then evenly push or roll the connecting collar down. Unroll the top sealing sheet over the drain. Cut a circular hole in the sealing sheet in the region of the drain - hole diameter approx. 10 mm. Note: the connecting collar must not be damaged! Roll back the sealing sheet. VL LBE EF S 3 3

6 6 Apply hot bitumen to the top side of the connecting collar (hot bitumen gluing process), or liquefy the bituminous material of the connecting collar by heating it (welding process). Unroll the sealing sheet again over the drain in the hot liquid bitumen, and then press or roll it down evenly. 7 7 Clamp the drainage ring into the clamping ring of the drain pot and then insert the stainless steel strainer with the strainer holding fixture. Two-piece version: 8 8 Cut out the thermal insulation according to the dimensions of the extension cartridge. Important: cut out a space for the flange as well, as it should be flushmounted into the substrate as far as possible. 9 9 Coat the whole of the inside of the previously inserted sealing element and the outside of the insert pipe of the extension cartridge with LORO lubricant. Then insert the extension cartridge into the drain pot in a backflow-safe manner. For installation heights/thermal insulation thickness see 2. 10 Connection of the connecting collar to the sealing sheet and installation of the strainer and the strainer holding fixture are as described under 1-7. Clamping of the combination connecting collar by the customer Normally the combination connecting collar is clamped in place at the factory. If on-site clamping is necessary, proceed as follows: 1.) Only use a combination connecting collar that has been pre-shaped at the factory. 2.) Place the combination connecting collar centrally over the fitted drain. The bituminous layer faces upwards. 3.) Heat the bituminous layer of the combination connecting collar in the area of the holes (clamping area) with an open flame or hot-air device. The surface must be shiny (but there must be no flame). 4.) Place the clamping ring centrally over the holes, and push it evenly, firmly and deeply into the pre-shaped, heated holes of the combination connecting collar. It may be necessary to push the clamping ring with a vertical wooden board in order to make sure that the pressing force is even..) Allow the combination connecting collar to cool down somewhat before further processing. 6.) Connect the combination connecting collar to the sealing sheet (see above for the procedure). 4 VL LBE EF S 4

b) PVC connecting collar for connecting to PVC sealing sheets made from plasticized polyvinyl chloride in accordance with DIN 16730 - e.g.: PVC-P-NB The PVC connecting collar 00 x 1. mm is a sealing sheet in accordance with DIN 16730 based on polyvinyl chloride (PVC-P-NB), manufacturer Braas, type Rhenofol C. The PVC connecting collar is connected to the existing PVC sealing sheet by means of solvent welding or hot gas welding. Hot-gas welding is preferable at low ambient temperatures - associated with high air humidity. Observe the manufacturer's instructions for jointing to sealing sheets. One-piece version: 1 1 Insert the drain pot in the slab cut-out and cast-in firmly in concrete. The flange should be mounted into the substrate flush with the surface and as neatly as possible. Seal slab cut-out. Cut-out measurements, see page 6. In order to protect the connecting collar during the building phase prior to the execution of sealing work, it is folded up in the factory and protected by a film. In order to process the connecting collar without problems after having carried out the cast in work, the collar must be unfolded. If the sealing work is delayed, precautions must be taken to protect the connecting collar against damage. 2 2 Unroll the sealing sheet over the drain. Cut a circular hole in the sealing sheet in the region of the drain - hole diameter approx. 10 mm. Hole measurements: approx. 230 mm. Note: the connecting collar must not be damaged. Thoroughly clean all the contact surfaces (they must be free from grease, free from dust and dry). First remove the protective foil from the LORO connecting collar. If the temperature is less than + C, pre-heat the area of the seam using the hot gas hand-welding unit. 3 3 Apply solvent welding agent every 0 mm to both sides of the seam region, and press down by hand. Then load the seams (e.g. with a sandbag). When using hot gas welding, close the seam with the hot gas hand-welding unit and pressure roller or with a welding machine. 4 Check the seams and rework them if necessary. Two-piece version: see 8-10 2.) Extension cartridge Connect extension cartridge, no. 199X, in case of two-piece version (use with balcony slab with thermal insulation), with sealing element, no. 911X,, to drain pot Adjustment ranges: Vertical drain pot Side drain pot Adjustment ranges 40-80 mm 80-120 mm 120-230 mm 40-120 mm 120-230 mm Instructions for laying cut to length continuously adjustable with extension pipe, no. 187X, can be trimmed to length cut to length with extension pipe, no. 187X, can be trimmed to length VL LBE EF S

3.) Drainage ring The drainage ring no. 1098X, is designed to drain off percolating and rainwater when draining over two storeys. It is clamped in the clamping ring and has two functions: a. With cams facing upwards = direct holder for flat strainer, no. 1093X. b. With cams facing downwards = holder for the strainer holding fixture, no. 1094X. 4.) Strainer holding fixture Cut the strainer holding fixture, no. 1094X, on site to the required height. If extension is required, use extension pipe no.187x, with sealing element no. 911X,. Adjustment ranges: Adjustment ranges Instructions for laying 3-140 mm 140-20 mm cut to length with extension pipe, no. 187X, can be trimmed to length.) Protective cover The drain pots of the LORO roof drains are supplied with a protective cover. This prevents dirt from getting into the drain pot or the down pipe during assembly. The protective cover is removed when assembly has proceeded far enough. 6.) Cut-out dimensions Y 240 Ø 240 Slab piercings Single drain, vertical outlet Core drillings, single stage for drains without thermal insulation Y 210 Ø 122 Y 240 Ø 240 Ø 122 T Slab cut-outs Single drain, side outlet 100 Core drillings, two-stage for drains without thermal insulation 13 d 3 Ø 240 B Core drillings, single stage for drains with thermal insulation Ø 18 DN 0 Cut-out depth T Cut-out width B a b a b d 3 110 130 130 160 72 70 130 10 130 160 92 a = without thermal insulation b = with thermal insulation VL LBE EF S 6 6

Notes VL LBE EF S 7 7

Representative dealers: 1 Rudolf Strauß GmbH industrial representation Tel.: +49(0)40.81 29 30 Fax: +49(0)40.81 29 0 industrievertretungen@r-strauss.de Internal service: Sascha Oeltze Tel.: +49(0)382 71-128 s.oeltze@lorowerk.de 2 Ralf Kaminski technical consultant Tel.: +49(0)4748.7 6 Mobile: +49(0)17.24 64 94 Fax: +49(0)4748.7 66 ralf.kaminski@lorowerk.de Internal service: André Pralle Tel.: +49(0)382 71-300 a.pralle@lorowerk.de 3 LORO-X warehouse west Harald Peglow Mewer Ring 7 844 Witten Tel.: +49(0)2302.913 160 Fax: +49(0)2302.880 3 witten@lorowerk.de Stefan Kruska industrial representation Fax: +49(0)220.908 789 Mobile: +49(0)172.209 27 77 kruska@kruska-industrievertretung.de Internal service: Monika Oeltze Tel.: +49(0)382 71-302 m.oeltze@lorowerk.de 4 Ullrich Stichnoth technical consultant Tel.: +49(0)6102.308 49 Mobile: +49(0)171. 210 39 30 Fax: +49(0)6102.308 83 ullrich.stichnoth@lorowerk.de Internal service: Natalia Henze Tel.: +49(0)382 71-223 n.henze@lorowerk.de Bernd Albert Skiba technical consultant Tel.: +49(0)382.932 91 32 Mobile: +49(0)160.97 90 04 3 Fax: +49(0)382.932 91 34 bernd.skiba@lorowerk.de Internal service: Thorsten Börstling Tel.: +49(0)382 71-22 t.boerstling@lorowerk.de 6 Udo Keidel technical consultant Tel.: +49(0)9372.13 44 19 Mobile: +49(0)160.901 31 46 Fax: +49(0)9372.1344 3 udo.keidel@lorowerk.de Internal service: Natalia Henze Tel.: +49(0)382 71-223 n.henze@lorowerk.de 7 Udo Keidel technical consultant Tel.: +49(0)9372.13 44 19 Mobile: +49(0)160.901 31 46 Fax +49(0)9372.1344 3 udo.keidel@lorowerk.de Wholesale support: Laufer Industrievertretungen GmbH Tel.: +49(0)8024.30 30 692 Mobile: +49(0)172.8 80 04 Fax: +49(0)8024.30 30 693 rudolf.laufer@laufer-iv.de Internal service: Hendrik Henze Tel.: +49(0)382 71-20 h.henze@lorowerk.de 8 Andreas Schneider technical consultant Tel.: +49(0)6222.663 97 4 Mobile: +49(0)160.989 70 44 Fax: +49(0)6222.663 97 48 andreas.schneider@lorowerk.de Internal service: Annette Jürries-Hoppmann Tel.: +49(0)382 71-296 a.juerries-hoppmann@lorowerk.de 9 LORO-X warehouse Baden-Württemberg Pierre Purgoll Turmstraße 49 1/2 89231 Neu-Ulm Tel.: +49(0)731.83300 Fax: +49(0)731.87116 neu-ulm@lorowerk.de Oliver Koch technical consultant Tel.: +49(0)7161.290 07 1 Mobile: +49(0)17.74 02 2 Fax: +49(0)7161.290 07 33 oliver.koch@lorowerk.de Internal service: Annette Jürries-Hoppmann Tel.: +49(0)382 71-296 a.juerries-hoppmann@lorowerk.de 10 Peter Wollitz technical consultant Tel.: +49(0)8861.713 72 01 Mobile: +49(0)170.921 16 62 Fax: +49(0)8861.910 98 69 peter.wollitz@lorowerk.de Wholesale support: Laufer Industrievertretungen GmbH Tel.: +49(0)8024.30 30 692 Mobile: +49(0)172.8 80 04 Fax: +49(0)8024.30 30 693 rudolf.laufer@laufer-iv.de Internal service: Hendrik Henze Tel.: +49(0)382 71-20 h.henze@lorowerk.de 11 Michael Heyne technical consultant Tel.: +49(0)342 0.42 69 0 Mobile: +49(0)160.9721603 Fax: +49(0)342 0.42 69 20 michael.heyne@lorowerk.de Wholesale support: Laufer Industrievertretungen GmbH Tel.: +49(0)8024.30 30 692 Mobile: +49(0)172.8 80 04 Fax: +49(0)8024.30 30 693 rudolf.laufer@laufer-iv.de Internal service: Hendrik Henze Tel. +49(0)382 71-20 h.henze@lorowerk.de 12 LORO Leipzig Iris Pohl, Susanne Kietz Tel.: +49(0)342 0.42 69 0 Fax: +49(0)342 0.42 69 20 E-mail: wb.leipzig@lorowerk.de Uwe Binngießer technical consultant Mobile: +49(0)160.97216092 uwe.binngiesser@lorowerk.de Michael Heyne technical consultant Mobile: +49(0)160.9721603 michael.heyne@lorowerk.de Hans-Christoph Müller technical consultant Mobile: +49(0)170.31442 hans-christoph.mueller@lorowerk.de Internal service: André Hoppmann Tel.: +49(0)382 71-301 a.hoppmann@lorowerk.de LOROWERK K.H.Vahlbrauk GmbH & Co.KG Kriegerweg 1, 3781 Bad Gandersheim, Tel.: +49(0)3 82.710, Fax: +49(0)3 82.712 03 Internet: www.loro.de, E-mail: infocenter@lorowerk.de LORO balcony drainages Contact 13 LORO Berlin Wholesale support: Ulrich Spigaht technical consultant Tel.: +49(0)30.981006 16 Mobile: +49(0)160.901047 Fax: +49(0)30.981006 29 ulrich.spigaht@lorowerk.de Internal service: André Hoppmann Tel.: +49(0)382 71-301 a.hoppmann@lorowerk.de Steffen Spigaht technical consultant Tel.: +49(0)30.981006 0 Mobile: +49(0)171.97 91 68 Fax: +49(0)30.981006 29 steffen.spigaht@lorowerk.de Stefan Günther Sales Manager Tel.: +49(0)264.96 49 1 Mobile: +49(0)17.291 78 64 stefan.guenther@lorowerk.de Heike Weiberg Internal Sales Manager Tel. +49(0)382 71-27 Fax +49(0)382 71-203 heike.weiberg@lorowerk.de Austria Thomas Flügel technical consultant Baumergasse 14/6 1210 Vienna, Austria Tel.: +43 1 290 14 47 Mobile: +43 664 413 320 0 thomas.fluegel@lorowerk.de Internal service: Christine Meier Tel.: +49(0)382 71-11 c.meier@lorowerk.de Switzerland Wisan Technik AG Gubelstr. 19 CH-6300 Zug Tel.: +41 41 711 03 Fax: +41 41 710 4010 info@wisan.ch Internal service: Thorsten Börstling Tel.: +49(0)382 71-22 t.boerstling@lorowerk.de Technical status: January 2016. Subject to technical changes. VL LBE EF S 8 3/VL LBE EF/2. 8