FINE-CLAD M-8911 Product Code: Carboxylated Polyester

Size: px
Start display at page:

Download "FINE-CLAD M-8911 Product Code: Carboxylated Polyester"

Transcription

1 September 7 FINE-CLAD M-8911 Product Code: Carboxylated Polyester DESCRIPTION FINE-CLAD M-8911 is a super durable carboxyl polyester designed to cure by triglycidyl isocyanurate crosslinkers for excellent weathering resistance. APPLICATIONS Exterior metals Outdoor furniture Architectural metals Automotive trims FEATURES Excellent exterior durability Excellent mechanical properties Good overbake properties Excellent flow PROPERTIES Appearance Solid Clear Granules Acid Value, mg KOH/g 35 Brookfield Viscosity at C, cps Color, Gardner, Solution 3 maximum Glass Transition Temperature, C 59 STORA FINE-CLAD resin is supplied in 25 Kg. bags. Store below 25 C temperature in a dry place to ensure a useful shelf life of at least one year. Read the FINE-CLAD M-8911 Material Safety Data Sheet before handling, storing, or using this product. Dust may be irritating and may present fire and explosion hazard. Use only with adequate ventilation and avoid breathing dust. Avoid contact with eye or skin.

2 Study Title Description Page # QUV A-3 and B-313 Data illustrates the excellent gloss retention properties 3 accelerated weathering study. using a standard white tion and accelerated weathering test equipment. South Florida weathering study. Data shows long term gloss retention based on South 4 Florida exposure of B- film thickness of 35-5 microns using a standard white tion. Physical properties. Data outlines typical cured film properties. 5 QUV-A-3 and B-313 ACCELERATED WEATHERING Data illustrates an excellent TGIC-cured tion for outdoor weathering based on M-8911 super-durable polyester. Accelerated weathering test data is outlined for a selected bake schedule. QUV A-3 and B-313 accelerated weathering data illustrates the excellent gloss retention properties obtained using this technology. Superdurable polyurethane (PU) powder coating is used as a control for weather testing. After 1, hours of QUV-A 3 exposure, nearly full gloss retention is observed. Formulation Tips: 1. Replacement of the standard flow modifier with Troy Powdermate 55 1% allows for a smoother surface and higher initial gloss value. 2. The use of Synthron Actiron (tetra butyl ammonium bromide) will allow for faster curing properties. The usage level will be dependent on desired cure schedule. 93. FINE-CLAD M TGIC Crosslinker, Araldite PT-81 (1) SUBTOTAL SUBTOTAL TOTAL.

3 Gloss Retention QUV-A 3 Gloss R etention - QUV B % Gloss Retention ( ) M-8911 Super Durable PU % Gloss Retention ( ) M-8911 Super Durable PU Exposure Time (hrs) Exposure Time (hrs) SOUTH FLORIDA WEATHERING A white, unfilled tion for natural weathering based on superdurable TGIC technology was developed and tested in South Florida, using a standard TGIC powder as a negative control and a superdurable polyurethane powder as a positive control. Weathering test data is outlined for a selected bake schedule. South Florida weathering data illustrates the excellent gloss retention properties obtained using FINE-CLAD M-8911 polyester cured with TGIC. After 48 months of South Florida exposure, 87% gloss retention is realized. 93. FINE-CLAD M TGIC Crosslinker, Araldite PT-81 (1) SUBTOTAL SUBTOTAL TOTAL.

4 Gloss Retention- South Florida Retention % Gloss Retention Total Exposure (yrs) FINE-CLAD M-8911 Control SD PU Control Standard TGIC PHYSICAL PROPERTY Data illustrates a white tion for obtaining excellent physical properties based on M-8911 superdurable polyester cured with TGIC. FINE-CLAD M-8911 gives excellent physical properties based on 93/7 ratio with TGIC. 93. FINE-CLAD M TGIC Cross-linker, PT-81 (1) SUBTOTAL SUBTOTAL TOTAL.

5 COATING PERFORMANCE Test Data Test Method Notes I Bake Schedule 1 4 C Film Thickness 35-5 microns, Bonderite panels Gloss / 95/12 PCI Smoothness (1) 5-6 (1) PCI flow rating 1-1 (1=best) Crosshatch Adhesion % Pencil Hardness 2H Solvent Cure Test (2) Partial Cure / Full Cure (2) PCI Test Method #8A, Gel C, seconds (3) 1 (3) PCI Test Method #6 Gardner Impact, Inch/ Lbs. Forward/Reverse 1/9 Pellet Flow (4) 83 (4) PCI Test Method #7