Current Blood Culture Methods and Systems: Clinical Concepts, Technology, and Interpretation of Results

Size: px
Start display at page:

Download "Current Blood Culture Methods and Systems: Clinical Concepts, Technology, and Interpretation of Results"

Transcription

1 40 Current Blood Culture Methods and Systems: Clinical Concepts, Technology, and Interpretation of Results Melvin P. Weinstein From the Departments ofmedicine and Pathology, University of Medicine and Dentistry ofnew Jersey-Robert Wood Johnson Medical School; and the Microbiology Laboratory, Robert Wood Johnson University Hospital, New Brunswick, New Jersey Since the mid-1970s there has been a number of advances in blood culture practices and technology; these advances have been based largely on well-designedcontrolled clinical evaluations of blood culture systems and media. Thus, a sound scientific basis for the fundamental principles of blood culturing now exists. In this article, I will address issues of clinical and technical importance with regard to blood culturing; these issues include skin antisepsis, the number and timing of blood cultures, the appropriate volume of blood for culture, culture media and additives, length and atmosphere of incubation, and interpretation of positive blood culture results. Finally, I will discuss the currently available blood culture systems, with an emphasis on the newer continuous-monitoring blood culture systems. Detection ofbacteremia and fungemia traditionally has been one of the most important functions of clinical microbiology laboratories. When blood cultures yield clinically important microorganisms, it is a sign that host defenses have failed to contain an infection at its primary site or that the clinician has failed to adequately eradicate the infectious process. During the past two decades, there has been a number of changes in blood culture practices; these changes have been based on clinical investigations that have established a stronger scientific basis for this diagnostic test. Moreover, manufacturers ofblood culture systems and media have improved their products, and there has been a marked trend toward the use of automated ('l systems-most recently, continuous-monitoring blood culture devices. In this review, I will focus on important clinical and technical issues related to blood culturing, as well as on the interpretation ofpositive blood cultures. Clinical Issues Skin antisepsis. The likelihood that a positive culture represents infection rather than contamination is, at least in part, a function of skin antisepsis at the time of culture. The recommended antiseptic preparations are 70% isopropyl alcohol, followed by an iodophor or iodine tincture [1]. lodophors require minutes of contact time for maximum antiseptic effect. Iodine tincture exerts its antiseptic effect more rapidly than do iodophors [2] and may lower contamination rates in institutions where these rates are high [3], including centers where house Received 4 March Reprints or correspondence: Dr. Melvin P. Weinstein, Robert Wood Johnson Medical School, 1 Robert Wood Johnson Place, New Brunswick, New Jersey Clinical Infectious Diseases 1996;23: by The Universityof Chicago. All rights reserved /96/ $02.00 officers and medical students, who may not wait for the iodophor to exert its effect, obtain the blood samples for culture. In one study, a commercially available skin-preparation kit for blood cultures has been shown to reduce contamination [4]. Method ofobtaining bloodfor culture. Venipuncture remains the method of choice for obtaining blood for culture; arterial blood cultures are not associated with higher diagnostic yields than are venous blood cultures [1]. Studies comparing contamination rates for blood cultures obtained from intravascular devices vs. those obtained by venipuncture have reported conflicting results [5-8]. My observations support those ofbryant and Strand [8], who noted significantly increased rates of contamination when blood for culture was obtained from intravenous catheters (P <.001). Furthermore, the American College of Physicians guidelines also recommend that blood for culture not be obtained from intravascular devices [9]. Although blood may occasionally be obtained from intravenous lines, a culture of blood obtained from such a device should be paired with another culture of blood obtained by peripheral venipuncture. Finally, I am unaware of published data from systematic studies that support obtaining separate blood samples from different ports of triplelumen catheters. Several recent studies have documented that the two-needle technique, formerly recommended for blood cultures, is not associated with significantly lower contamination rates than is the single-needle technique [10-12]. Because the handling of any needle is associated with a small but finite risk of needlestick injury, the authors of these studies have recommended that the single-needle method become the standard. However, the results of a recently published meta-analysis have suggested that the two-needle method may reduce contamination rates slightly [13]. Nevertheless, pending further data, the singleneedle method probably should continue to be the standard. Number of blood cultures. Several studies have addressed the issue of the number of blood cultures needed to detect

2 em 1996;23 (July) Current Blood Culture Methods 4\ bacteremia and fungemia in adults. Washington [14] reported the cumulative yield from three 20-mL blood samples obtained in sequence and cultured with use of conventional manual methods; 64 (80%) of 80 bacteremic epidoses were detected with the first culture, 70 (88%) of 80 were detected with the first two cultures, and 79 (99%) of 80 were detected with three blood cultures. My colleagues and I also used conventional manual methods and found that the first blood culture detected 257 (91%) of 282 bacteremic episodes and that the first two blood cultures detected 281 (>99%) of 282 episodes [15]. More recently my colleagues and I used the BacT/Alert continuous-monitoring blood culture system (Organon Teknika, Durham, NC) and evaluated the yield of clinically important microorganisms from three consecutive 20-mL blood samples obtained and cultured during a 24-hour period [16]. During a 15-month period, three blood cultures were performed for 218 patients; the third blood culture was the only one positive on only six occasions, and only one of these positive cultures represented true sepsis. The conclusion that we drew from this small quality assurance study was that for the great majority of patients, two blood cultures should be sufficient to detect septicemia. On the other hand, single blood cultures should be discouraged, if not forbidden altogether [9]. Not only will single blood cultures be insufficiently sensitive for detecting some bacteremias and fungemias, but they also may be difficult to interpret. For example, a single blood culture that yields a coagulasenegative staphylococcus may represent contamination or clinically important infection. However, if two samples obtained in sequence by separate venipunctures yield the same coagulasenegative staphylococcal species with the same antibiogram, the probability is high that the isolates represent true bacteremia. On the basis of the concepts reviewed above, laboratories should recommend two blood cultures under routine circumstances. In institutions where phlebotomists or nurses obtain the blood for culture, two blood cultures should be performed automatically, even when the physician orders a single culture. On the other hand, ordering more than two blood cultures during any 24-hour period probably is unnecessary, except when the physician wishes to document the continuous bacteremia associated with an endovascular infection such as endocarditis. Therefore, it may be appropriate to require the approval of the laboratory director when more than two (or perhaps three) blood cultures are ordered during any 24-hour period. Timing of blood cultures. Few studies have systematically evaluated the timing of blood cultures and the optimum interval between successive blood cultures. Strand [17] has arbitrarily recommended a 30- to 60-minute interval except for critically ill, septic patients, from whom specimens should be obtained minutes before initiating therapy. Li et al. [18] recently showed no difference in yield whether blood samples for cultures performed within a 24-hour period were drawn simultaneously or at spaced intervals [18]. However, drawing blood at intervals may be helpful if the clinician wishes to document continuous bacteremia in patients with suspected endovascular infections. Technical Factors Many technical factors affect the sensitivity of blood culture systems. Of these factors, the most important are probably the volume of blood cultured and the broth medium used for culture. Other important factors include the ratio of blood to broth, agitation during incubation, length of incubation, atmosphere of incubation, and additives to the media (e.g., those that neutralize the effect of antimicrobial agents present in the blood at the time the sample is drawn). These and other technical issues have been reviewed in detail elsewhere [1, 19, 20], and the reader is referred to those publications for additional discussion of these matters. Volume of blood required for culture. During bloodstream infections, especially those in adults, there may be relatively few microorganisms present in a given volume of bloodoften in the range of < 1-10 cfu/ml. Moreover, in numerous studies of adult patients, a direct relationship between the diagnostic yield of blood cultures and the volume of blood cultured has been documented [21-24]. On the basis of this information, the recommended volume of blood per culture set for an adult is ml [1], and the preferred volume is ml. Blood volumes of > 30 ml do not enhance the diagnostic yield and contribute to nosocomial anemia; as a practical matter, blood at these volumes may clot in the syringe, thereby making it impossible to inoculate the blood culture bottles. The optimal volume of blood that should be obtained from children has not been defined with certainty [25]. However, for infants and small children, Szymczak et al. [26] concluded that the chance of failing to detect bacteremia was greater with blood volumes of < 1 ml per culture than with blood volumes of ~ 1 ml. On the basis of the available data, Paisley and Lauer [25] have recommended 1-2 ml of blood per culture for neonates, 2-3 ml for infants aged I month to 2 years, 3 5 ml for older children, and ml for adolescents. Culture media. All but one of the commercially available blood culture systems marketed in the United States are based on the inoculation of blood into broth culture media. No one medium or system is capable of detecting all microorganisms. Thus the results of innumerable clinical studies that evaluated different blood culture media and additives have been published. In general, most commercially marketed blood culture media perform well. However, many manufacturers supplement their base media with proprietary additives designed to enhance microbial growth, and it cannot be assumed that common generic media (e.g., supplemented soybean casein digest broth) from different manufacturers will perform in an equivalent manner. Decisions as to the choice of media formulations should be based on data from well-controlled field trials in which large numbers of cultures were assessed. The U.S. Food and Drug Administration has recently issued guidelines for

3 42 Weinstein em 1996; 23 (July) manufacturers that sponsor such clinical field trials; these guidelines have been summarized by Wilson [27]. Blood-to-broth ratio. Human blood contains a number of substances (e.g., complement, lysozyme, and phagocytic WBCs) capable of inhibiting microbial growth. Moreover, nearly one-third of patients are receiving antimicrobial agents at the time blood for cultures is obtained (author's unpublished observations). Thus, to optimize the diagnostic yield, blood should be diluted adequately in the culture broth to minimize the effect of these substances. The results of studies that have addressed this issue have led to the recommendation that blood be diluted fivefold to tenfold [28-30]. Dilutions of <1:5 may result in a reduced yield; thus, filling blood culture bottles with more than the recommended amount of blood should be avoided. Dilutions of > 1:10 may also be associated with a reduced yield that is not based on blood-to-broth ratio but rather on inadequate blood volume for culture. Although commercially available blood culture bottles have a partial vacuum in the headspace, direct-draw techniques may result in overfilling and reduced blood-to-broth ratios. Collection of specimens with a needle and syringe provides greater control for inoculating blood culture bottles with the correct amount of blood and thus is preferred. Neutralization and inactivation of antimicrobials. Given the frequency with which blood for cultures is obtained from patients already receiving antimicrobial agents, several manufacturers have marketed products designed to counteract the potential inhibitory effect on growth. These include the antimicrobial removal device (ARD; Becton Dickinson Microbiology Systems, Cockeysville, MD), BACTEC resin-containing media (Becton Dickinson Diagnostic Instrument Systems, Sparks, MD), and BacT/Alert FAN media (Organon Teknika). The ARD, which was first introduced in 1980, has been the subject of many studies that have not defined a clear mandate for its use. By contrast, the results of studies of BACTEC resin media used with the semiautomated radiometric (BACTEC 460) and nonradiometric (BACTEC 660 and 730) systems generally were favorable [20]. In one study in which aerobic nonradiometric resin medium was used, the authors speculated that the improved yield of microorganisms might be due, at least in part, to factors other than the binding of antibiotics [31]. The resin medium is available for use in BACTEC continuous-monitoring blood culture devices (9240 and 9120). The manufacturer ofthe BacT/Alert continuous-monitoring blood culture instrument has recently marketed an aerobic medium, FAN, that uses activated charcoal in a proprietary substance (Ecosorb) to counter the potential inhibitory effects ofantibiotics. Use of both the aerobic and the as yet unmarketed anaerobic formulations of the FAN media was associated with improved yields when they were compared with the standard BacT/Alert media [32 33]. The results of a comparative study of the FAN and BAC TEC resin media suggest that the performance ofthese media is equivalent in the respective continuous-monitoring blood culture instruments [34]. Atmosphere ofincubation. Traditional two-bottle blood culture systems have included one aerobic bottle and one anaerobic bottle, with the blood distributed equally between the two bottles. However, during the past two decades, the proportion of bacteremias due to obligate anaerobes has decreased substantially [35-37], leading some authorities to question the need for routine use of the anaerobic bottle. In fact, several recent studies of adults [35, 38, 39] and children [40] have concluded that the routine use of anaerobic blood culture bottles is not necessary and have recommended that these bottles be used only selectively for patients who are at high risk for bacteremia due to anaerobes. Whether the data from these studies can be generalized to all institutions remains a subject of controversy for several reasons. Only a limited number of culture media and systems have been evaluated in these studies; for example, reports that assess the relative value of the BACTEC anaerobic resin or lytic media, the BacT/Alert anaerobic FAN medium, or the ESP anaerobic (80N) medium (Difco, Detroit) have not been published. Moreover, selective use ofanaerobic bottles requires that certain logistic issues be addressed within each institution. These issues include notifying physicians and staff of the change in procedure and the reasons the change was implemented; determining which, if any, nursing units (e.g., the gynecologic unit and the colon and rectal surgery unit) should be stocked routinely with anaerobic bottles; and, possibly, developing algorithms for the physicians ordering blood cultures or for the individuals obtaining the blood for culture (i.e., the phlebotomists, nurses, clinical care technicians, house officers, and medical students). Indeed, an orderly and stepwise plan that includes both inservice education and postimplementation quality assurance evaluations to confirm that the recommended blood culture protocols are being followed should be developed at institutions where these changes are implemented. Length ofincubation ofblood cultures. In routine circumstances, blood cultures need not be incubated for > 7 days. Indeed, several recent studies in which instrumented blood culture systems were used have shown that 5-day incubation periods are sufficient for detecting the majority of pathogens [41-44]. Moreover, after 5 days most newly positive cultures represent contamination [44]. Incubation periods longer than 7 days may be useful when fungemia or bacteremia due to fastidious organisms such as the HACEK group of bacteria or species of Legionella or Brucella are suspected. Longer incubation periods may also be useful for patients with suspected endocarditis who have been treated with antimicrobial agents before blood cultures are performed. However, Washington [45] has noted that such extended incubation periods rarely increase yield. Mycobacterial blood cultures should be incubated for ~4 weeks. Microorganisms that Deserve Special Consideration Yeasts andfilamentousfungi. The incidence offungemia has increased in recent decades because of the AIDS epidemic and

4 ern 1996;23 (July) Current Blood Culture Methods 43 because patients with malignancies survive longer, the number of patients with organ transplants has increased, and long-term indwelling intravascular devices are being used more frequently. The Isolator (Wampole Laboratories, Cranbury, NJ) lysis-centrifugation system continues to be the best system for detecting filamentous fungi. The Septi-Chek biphasic blood culture system (Becton Dickinson) also has performed well. Instrumented blood culture systems in which the newer media (e.g., the BACTEC aerobic resin, nonradiometric fungal media, and the BacT/Alert aerobic FAN medium) are used have performed well for the detection ofyeasts other than Cryptococcus neoformans [32, 34, 46, 47]. Mycobacteria. Before the AIDS epidemic, blood cultures for detecting mycobacteria were rarely, if ever, performed. However, mycobacterial blood cultures are now commonly performed in many laboratories. The Isolator system and the BACTEC radiometric system with l3a media have excellent sensitivity and perform comparably [48, 49]. Manufacturers of continuous-monitoring blood culture systems are in various stages of evaluating these devices in terms of their utility for mycobacterial blood cultures, but no published data are yet available. Blood Culture Systems that Are Currently Available Manual bloodculture systems. Conventional manual systems and media are available from many commercial sources. Aerobic blood culture bottles and (usually) anaerobic blood culture bottles are inoculated with blood and usually incubated for 7 days. Each bottle is examined daily for macroscopic evidence of microbial growth (e.g., hemolysis, turbidity of the media, gas production, or formation of discrete colonies). An aliquot ofthe contents of the aerobic bottle is gram stained and subcultured after the first overnight incubation. A terminal subculture is usually done at the end of the incubation period. Conventional manual systems are flexible and require no purchase of expensive instruments, but they are labor intensive. The biphasic Septi-Chek system and the Opticult blood culture systems (Becton Dickinson) and the Oxoid Signal broth displacement blood culture system (Oxoid Unipath, Basingstoke, England) are labor-saving variations of the conventional manual method. The Septi-Chek and Opticult systems utilize agar-coated paddles or slants attached to the broth-containing culture bottle and allow subcultures to be done daily or more frequently by inverting the blood-broth mixture so that it covers the agar. Microbial growth is often identified on the agar rather than in the broth, allowing for prompt preliminary identification and susceptibility testing. As mentioned earlier, comparative studies have shown that the Septi-Chek biphasic system performs well in detecting yeasts and other microorganisms [31, 50-52]. The Oxoid Signal system is a one-bottle system. After blood is inoculated into the bottle, a clear-plastic cylindrical signal device is attached to the top of the bottle; a long needle from the lower end of the device extends below the surface of the blood-broth mixture, creating a closed system. Gases produced as a by-product of microbial growth increase the pressure in the headspace and force some of the blood-broth mixture through the needle into the cylinder, thereby "signaling" a positive culture. Comparasons of this system with other manual systems and with the BACTEC radiometric system have yielded mixed results [53-56]. The Isolator is a unique manual blood culture system that is based on lysis ofblood cells, centrifugation, and direct inoculation of the centrifugate into solid media. For children, from whom only small volumes of blood may be collected, the centrifugation step is deleted. Many studies that have compared the Isolator system with other systems have been reported (as reviewed by Doern [57]). Overall, the Isolator system performs well in the detection of most microorganisms-especially yeasts, filamentous fungi, mycobacteria, and opportunists such as Bartonella (Rochalimaea) henselae. Certain microorganisms, including Streptococcus pneumoniae, other streptococci, Pseudomonas aeruginosa, and anaerobic bacteria, may not be recovered optimally with this system. A potential advantage of the system is that it allows quantitation of the level of bacteremia or fungemia. Disadvantages of the Isolator system include the following: the lysing solution is toxic for some microorganisms; specimens must be processed within 8 hours of blood collection (most microbiology laboratories are staffed for only one daily shift); substantial labor is required for the initial processing of Isolator cultures; and the contamination rates for this system are higher than those for conventional broth and automated systems. Instrumented blood culture systems. Commercially available intsrumented blood culture methods were introduced in the 1970s. Until recently, the BACTEC instrumented systems were the only products commercially available in the United States; these systems were initially equipped with radiometric instruments and media, followed in the mid-1980s by the nonradiometric instruments and media. Both systems (as well as in the newer BACTEC and BacT/Alert continuous-monitoring devices) are based on the utilization of carbohydrate substrates in the culture media and subsequent production of CO2 by growing microorganisms. For the radiometric system, the instrument detects 14C02 in the bottle headspace, and for the nonradiometric system, CO2 is detected by infrared spectrophotometry. For both systems, bottles are loaded onto the detection portion of the instrument, where needles perforate the bottle diaphragm and sample the gas contents of the headspace once or twice daily; a bottle is flagged as positive if the amount of CO 2 in the bottle exceeds a threshold value. The flagged bottle is then removed from the instrument, and an aliquot of its contents is gram-stained and subcultured for further testing. Numerous controlled clinical evaluations of the BACTEC radiometric and nonradiometric

5 44 Weinstein em 1996;23 (July) systems and media have been published; the advantages and disadvantages ofthese systems have been summarized recently by Wilson et al. [58]. Continuous-monitoring blood culture systems. With changes in health care financing, including the recognition that labor costs need to be better controlled, manufacturers are increasingly looking to the use ofautomation in clinical microbiology. The early-generation BACTEC instruments had the following disadvantages: culture bottles had to be manually manipulated, gas canisters were needed for every instrument; detection needles had to be changed periodically; sterilization ofthe needle devices occasionally failed, resulting in a false diagnosis of bacteremia (pseudobacteremia); cultures were sometimes instrument false-positive; and bottle throughput was relatively slow (35-60 seconds per bottle). Continuous-monitoring blood culture systems were developed in an effort to address these problems. Three ofthese systems are currently available in the United States: the BACTEC 9000 series (Becton Dickinson), Difco ESP, and the BacT/Alert, which was the first to be marketed in All systems have several features in common including self-contained modular incubation; agitation; detection units, of which up to five or six can be controlled by a single computer; lack of the need for manual manipulation of culture bottles once they have been loaded into the instrument; instrument monitoring ofmicrobial growth at 10- to 24-minute intervals; and culture bottles that each accept 10 ml of blood. The BacT/Alert and BACTEC systems detect the production of CO 2 as change in ph; this is accomplished by means of colorimetry in the BacT/Alert system and by means of a fluorescent sensor in the BACTEC system. The ESP system detects changes in pressure, either as gases are used during early microbial growth or as they are produced later during growth. The BacT/Alert and BACTEC systems monitor every bottle at 10 minute intervals and gently rock all bottles 34 and 30 times a minute, respectively. The ESP system monitors aerobic bottles every 12 minutes and agitates them at 160 cycles per minute; anaerobic bottles are monitored every 24 minutes without agitation. All comparative studies to date have shown that the three continuous-monitoring blood culture systems have detected growth sooner than earlier-generation BACTEC instruments and manual systems [46, 59-66]; these systems have been found to be comparable in terms of performance [66, 67]. All three systems have performed reliably in my laboratory. Interpretation of Positive Blood Cultures Since the presence of a bloodstream infection is important in terms ofboth diagnosis and prognosis, correct interpretation of the positive test result is crucial. Misinterpretation of positive results can be costly both to the institution and to the patient. Bates and colleagues [68] recently calculated that the excess cost associated with each blood culture contaminant was ""$4,500 [68]. Parameters that may be useful in interpreting results include the identity of the microorganism, the presence of more than one blood culture positive for the same microorganism, and the presence of the same microorganism as that found in the blood from another normally sterile site. Microorganisms that almost always (>90% of isolates) represent true infection when isolated from the blood include Staphylococcus aureus, Escherichia coli and other Enterobacteriaceae, P. aeruginosa, S.pneumoniae, and Candida albicans. Isolates from blood that rarely «5% of isolates) represent true infection include Corynebacterium species, Bacillus species, and Propionibacterium acnes. Coagulase-negative staphylococci are particularly problematic, not only because they are so ubiquitous, but also because 12%-15% ofthe blood isolates are pathogens rather than contaminants [69]. Some authorities have suggested that the number of bottles positive in a culture set is a predictor of the clinical significance of an isolate. However, Mirrett and colleagues [70] and Peacock et al. [71] have found that this criterion is unreliable, at least for coagulase-negative staphylococci. A useful interpretive concept is the number of culture sets found to be positive vs. the number obtained. If most or all cultures in a series are positive, regardless of the microorganism recovered, the probability that the organism is clinically important is high [15]. Of course, it is the physician who must ultimately make the final judgment, taking into account not only the laboratory findings but also the clinical presentation of the patient. Limitations of Blood Cultures Blood cultures, as described herein, currently represent the "gold standard" for diagnosis ofsepticemia. Nonetheless, they have limitations. Positive results require hours to days of incubation. No one culture medium or system in use has been shown to be best suited to the detection of all potential bloodstream pathogens. Some microorganisms grow poorly, or not at all, in conventional blood culture media and systems. Whether culture-based systems will remain the diagnostic methods of choice into the next century or be replaced by molecular techniques or other methods remains to be determined. References 1. Reller LB, Murray PR, MacLowry JD. Blood cultures II. In: Washington la II, ed. Cumitech IA. Washington, DC: American Society for Microbiology, King TC, Price PB. An evaluation of iodophors as skin antiseptics. Surg Gynecol Obstet 1963; 116: Strand CL, Wajsbort RR, Sturmann K. Effect of iodophor vs. iodine tincture skin preparation on blood culture contamination rate. lama 1993; 269: Schifman RB, Pindur A. The effect of skin disinfection materials on reducing blood culture contamination. Am 1 Clin Pathol 1993; 99: Tonnesen A, Peuler M, Lockwood WR. Cultures ofblood drawn by catheters vs. venipuncture. lama 1976;235:1877.

6 CID 1996;23 (July) Current Blood Culture Methods Felices FJ, Hernandez JL, Ruiz J, Meseguer J, Gomez JA, Molina E. Use of the central venous pressure catheter to obtain blood cultures. Crit Care Med 1979; 7: Tafuro P, Colbourn D, Gurevich I, et al. Comparison of blood cultures obtained simultaneously by venepuncture and from vascular lines. J Hosp Infect 1986; 7: Bryant JK, Strand CL. Reliability of blood cultures collected from intravascular catheter versus venipuncture. Am J Clin Pathol 1987;88: Aronson MD, Bor DR Blood cultures. Ann Intern Med 1987; 106: Isaacman DJ, Karasic RE. Utility of collecting blood cultures through newly inserted intravenous catheters. Pediatr Infect Dis J 1990;9: II. Krumholz HM, Cummings S, York M. Blood culture phlebotomy: switching needles does not prevent contamination. Ann Intern Med 1990; 113: Leisure MK, Moore DM, Schwartzman JD, Hayden GF, Donowitz LG. Changing the needle when inoculating blood cultures: a no-benefit and high-risk procedure. JAMA 1990;264: Spitalnic SJ, Woolard RH, Mermel LA. The significance of changing needles when inoculating blood cultures: a meta-analysis. Clin Infect Dis 1995;21: Washington JA II. Blood cultures: principles and techniques. Mayo Clin Proc 1975;50: Weinstein MP, Reller LB, Murphy JR, Lichtenstein KA. The clinical significance of positive blood cultures: a comprehensive analysis of 500 episodes of bacteremia and fungemia in adults. I. Laboratory and epidemiologic observations. Rev Infect Dis 1983;5: Weinstein MP, Joho KL, Quartey SM. Assessment of the third blood culture: does it increase detection of bacteremia [abstract no C 150]. In: Program and abstracts of the 94th General Meeting of the American Society for Microbiology (Las Vegas). Washington, DC: American Society for Microbiology, 1994: Strand CL. Blood cultures: consensus recommendations in Microbiology no. MB 88-1 (MB-I72). American Society for Clinical Pathologists Check Sample Continuing Education Program. Chicago: American Society for Clinical Pathologists, Li J, Plorde 11, Carlson LG. Effects of volume and periodicity on blood cultures. J Clin Microbiol 1994; 32: Wilson ML, Weinstein MP. General principles in the laboratory detection of bacteremia and fungemia. Clin Lab Med 1994; 14: Washington JA II, Ilstrup DM. Blood cultures: issues and controversies. Rev Infect Dis 1986; 8: Hall MM, Ilstrup DM, Washington la II. Effect of volume of blood cultured on detection of bacteremia. J Clin MicrobioI1976;3: Ilstrup DM, Washington la II. The importance of volume of blood cultured in the detection of bacteremia and fungemia. Diag Microbiol Infect Dis 1983; 1: Plorde 11,Tenover FC, Carlson LG. Specimen volume versus yield in the BACTEC blood culture system. 1 Clin Microbiol 1985;22: Tenney JH, Reller LB, Mirrett S, Wang W-LL, Weinstein MP. Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemia. 1 Clin Microbiol 1982; 15: Paisley lw, Lauer BA. Pediatric blood cultures. Clin Lab Med 1994; 14: Szymczak EG, Barr JT, Durbin WA, Goldmann DA. Evaluation of blood culture procedures in a pediatric hospital. J Clin Microbiol 1979; 9: Wilson ML. Introduction. Clin Lab Med 1994; 14: Auckenthaler R, Ilstrup DM, Washington la II. Comparison of recovery of organisms from blood cultures diluted 10% (volume/volume) and 20% (volume/volume). 1 Clin Microbiol 1982; 15: Salventi IF, Davies TA, Randall EL, Whitaker S, Waters lr. Effect of blood dilution on recovery of organisms from clinical blood cultures in medium containing sodium polyanethol sulfonate. J Clin Microbiol 1979; 9: Reller LB, Lichtenstein KA, Mirrett S, Wang W-LL. Controlled evaluation of the ratio of blood to broth in the detection of bacteremia by blood culture [abstract 177]. In: Programs and abstracts of the Annual Meeting of the American Society for Microbiology (Las Vegas). Washington, DC: American Society for Microbiology, 1978: Weinstein MP, Mirrett S, Wilson ML, Harrell LJ, Stratton CW, Reller LB. Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles. 1 Clin Microbiol 1991; 29: Weinstein MP, Mirrett S, Reimer LG, et al. Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol 1995; 33: Wilson ML, Weinstein MP, Mirrett S, et al. Controlled evaluation of BacT! Alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia. 1 Clin Microbiol 1995; 33: Pohlman lk, Kirkley BA, Easley KA, Basille BA, Washington la. Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT!Alert aerobic FAN bottles for detection of bloodstream infections. 1 Clin Microbiol 1995;33: Murray PR, Traynor P, Hopson D. Critical assessment of blood culture techniques: analysis of recovery of obligate and facultative anaerobes, strict aerobic bacteria, and fungi in aerobic and anaerobic blood culture bottles. 1 Clin Microbiol 1992; 30: Dorsher CW, Rosenblatt JE, Wilson WR, Ilstrup DM. Anaerobic bacteremia: decreasing rate over a 15-year period. Rev Infect Dis 1991; 13: Lombardi DP, Engleberg NC. Anaerobic bacteremia: incidence, patient characteristics, and clinical significance. Am J Med 1992; 92: Morris AJ, Wilson ML, Mirrett S, Reller LB. Rationale for selective use of anaerobic blood cultures. 1 Clin Microbiol 1993; 31: Sharp SE, McLaughlin JC, Goodman 1M, et al. Clinical assessment of anaerobic isolates from blood cultures. Diagn Microbiol Infect Dis 1993; 17: Zaidi AKM, Knaut AL, Mirrett S, Reller LB. Value of routine anaerobic blood cultures for pediatric patients. J Pediatr 1995; 127: Evans MR, Truant AL, Kostman 1, Locke L. The detection of positive blood cultures by the BACTEC NR660. The clinical importance of four-day versus seven-day testing. Diagn Microbiol Infect Dis 1991; 14: Hardy Dl, Hulbert BB, Migneault Pc. Time to detection of positive BacT! Alert blood cultures and lack of need for routine subculture of 5- to 7 day negative cultures. 1 Clin Microbiol 1992;30: Masterson KC, McGowan JE lr. Detection of positive blood cultures by the BACTEC NR660: the clinical importance of five versus seven days of testing. Am 1 Clin Pathol 1988;90: Wilson ML, Mirrett S, Reller LB, Weinstein MP, Reimer LG. Recovery of clinically important microorganisms from the BacT!Alert blood culture system does not require testing for seven days. Diagn Microbiol Infect Dis 1993; 16: Washington la. Collection, transport, and processing of blood cultures. Clin Lab Med 1994; 14: Wilson ML, Weinstein MP, Reimer LG, Mirrett S, Reller LB. Controlled comparison of the BacT!Alert and BACTEC nonradiometric blood culture systems. J Clin Microbiol 1992;30: Smith JA, Bryce EA, Ngui-Yen lh, Roberts FJ. Comparison ofbactec 9240 and BacT!Alert blood culture systems in an adult hospital. 1 Clin Microbiol 1995; 33: Kiehn TE, Cammarata R. Comparative recoveries of Mycobacterium avium-m. intracellulare from Isolator lysis-centrifugation and BACTEC 13A blood culture systems. J Clin Microbiol 1988; 26: Witebsky FG, Keiser IF, Conville PS, et al. Comparison of BACTEC 13A medium and DuPont Isolator for detection of mycobacteremia. 1 Clin Microbiol 1988;26:

7 46 Weinstein ern 1996;23 (July) 50. Pfaller MA, Sibley TK, Westfall LM, Hoppe-Bauer JE, Keating MA, Murray PRo Clinical laboratory comparison of a slide blood culture system with a conventional broth system. J Clin Microbiol 1982; 16: Henry NK, Grewell CM, McLimans CA, Washington JA II. Comparison of the Roche Septi-Chek blood culture bottle with a brain heart infusion biphasic medium bottle and with a tryptic soy broth bottle. J Clin MicrobioI1984;19: Weinstein MP, Reller LB, Mirrett S, Stratton CW, Reimer LG, Wang W-LL. Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia. J Clin Microbiol 1986;23: Weinstein MP, Mirrett S, Reimer LG, Reller LB. Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid signal blood culture system versus the BACTEC radiometric system. J Clin MicrobioI1989;27: Murray PR, Niles AC, Heeren RL, Curren MM, James LE, Hoppe-Bauer JE. Comparative evaluation of the Oxoid Signal and Roche Septi-Chek blood culture systems. J Clin Microbiol 1988;26: Weinstein MP, Mirrett S, Reller LB. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia. J Clin MicrobioI1988;26: Daley C, Lim I, Modra J, Wilkinson I. Comparative evaluation of nonradiometric BACTEC and improved Oxoid signal blood culture systems in a clinical laboratory. J Clin Microbioll990;28: Doem GV. Manual blood culture systems and the antimicrobial removal device. Clin Lab Med 1994; 14: Wilson ML, Weinstein MP, Reller LB. Automated blood culture systems. Clin Lab Med 1994; 14: Nolte FS, Williams JM, Jerris RC, et al. Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescentsensor technology (BACTEC 9240). J Clin Microbioll993;31 : Krisher KK, Whybum DR, Koepnick FE. Comparison of the BacT/Alert pediatric blood culture system, Pedi-Bac'I', with conventional culture using the 20-milliliter Becton-Dickinson supplemented peptone broth tube. J Clin Microbioll993;31: Kirkley BA, Easley KA, Washington JA. Controlled clinical evaluation of Isolator and ESP aerobic blood culture systems for detection of bloodstream infections. J Clin Microbioll994;32: Kellogg JA, Bankert DA, Manzella JP, Parsey KS, Scott SL, Cavanaugh SH. Clinical comparison of isolator and thiol broth with ESP aerobic and anaerobic bottles for recovery of pathogens from blood. J Clin Microbioll994;32: Rohner P, Pepey B, Auckenthaler R. Comparison of BacT/Alert with Signal blood culture system. J Clin Microbioll995;33: Welby PL, Keller DS, Storch GA. Comparison of automated Difco ESP blood culture system with biphasic BBL Septi-Chek system for detection of bloodstream infections in pediatric patients. J Clin Microbiol 1995; 33: Hellinger WC, Cawley JJ, Alvarez S, et al. Clinical comparison of the Isolator and BacT/Alert aerobic blood culture systems. J Clin Microbiol 1995;33: Pohlman JK, Kirkley BA, Easley KA, Washington JA. Controlled clinical comparison of Isolator and BACTEC 9240 aerobiclf resin bottle for detection of bloodstream infections. J Clin Microbiol 1995;33: Zwadyk P Jr, Pierson CL, Young C. Comparison of Difco ESP and Organon Teknika BacT/Alert continuous-monitoring blood culture systems. J Clin MicrobiolI994;32:l Bates OW, Goldman L, Lee TH. Contaminant blood cultures and resource utilization: the true consequences of false-positive results. JAMA 1991; 265: Towns ML, Quartey SM, Weinstein MP, Reimer LG, Reller LB. The clinical significance of positive blood cultures: a prospective, multicenter investigation [abstract C232]. In: Program and abstracts of the 93rd General Meeting of the American Society for Microbiology (Atlanta). Washington, DC: American Society for Microbiology, 1993: Mirrett S, Weinstein MP, Reimer LG, Wilson ML, Reller LB. Interpretation of coagulase-negative staphylococci in blood cultures: does the number of positive bottles help? [abstract C69]. In: Program and abstracts of the 93rd General Meeting of the American Society for Microbiology (Atlanta). Washington, DC: American Society for Microbiology, 1993: Peacock SJ, Bowler ICJW, Crook OWM. Positive predictive value of blood cultures growing coagulase-negative staphylococci [letter]. Lancet 1995;346:191-2.

Comparative Analysis between Monophasic and Biphasic Methods of Blood Culture

Comparative Analysis between Monophasic and Biphasic Methods of Blood Culture Comparative Analysis between Monophasic and Biphasic Methods of Blood Culture M.O. Salami 1*, S.O. Alu 1, A.B. Opalekunde 2 and O.A. Oladipo 1 1.Department of Biology, Institute of Basic and Applied Sciences,

More information

Comparative Evaluation of the Oxoid Signal and Roche Septi-Chek Blood Culture Systems

Comparative Evaluation of the Oxoid Signal and Roche Septi-Chek Blood Culture Systems JOURNAL OF CLINICAL MICROBIOLOGY, Dec. 1988, p. 2526-2530 0095-1137/88/122526-05$02.00/0 Copyright 1988, American Society for Microbiology Vol. 26, No. 12 Comparative Evaluation of the Oxoid Signal and

More information

System with BACTEC Radiometric Blood Culture Media

System with BACTEC Radiometric Blood Culture Media JOURNAL OF CLINICAL MICROBIOLOGY, Oct. 1984, p. 618-623 0095-1137/84/100618-06$02.00/0 Copyright 1984, American Society for Microbiology Vol. 20, No. 4 Clinical Laboratory Comparison of the 10-ml Isolator

More information

Standard Operating Procedure

Standard Operating Procedure Subject Blood Culture Collection Index Number Lab-1325 Section Laboratory Subsection Specimen Collection and Processing Category Departmental Contact Regina Collins Last Revised 3/17/2017 References Required

More information

美国范德堡大学医学中心临床微生物实验室主任 缺照片. Dr. Charles W. Stratton, IV

美国范德堡大学医学中心临床微生物实验室主任 缺照片. Dr. Charles W. Stratton, IV Dr Stratton is currently Associate Professor of Pathology and Medicine and Director of the Clinical Microbiology Laboratory at the Vanderbilt University Medical Center in Nashville, Tennessee. Dr Stratton

More information

Optimized Pathogen Detection with 30- Compared to 20-Milliliter Blood Culture Draws

Optimized Pathogen Detection with 30- Compared to 20-Milliliter Blood Culture Draws JOURNAL OF CLINICAL MICROBIOLOGY, Dec. 2011, p. 4047 4051 Vol. 49, No. 12 0095-1137/11/$12.00 doi:10.1128/jcm.01314-11 Copyright 2011, American Society for Microbiology. All Rights Reserved. Optimized

More information

Received 2 September 1997/Returned for modification 14 October 1997/Accepted 24 November 1997

Received 2 September 1997/Returned for modification 14 October 1997/Accepted 24 November 1997 JOURNAL OF CLINICAL MICROBIOLOGY, Mar. 1998, p. 657 661 Vol. 36, No. 3 0095-1137/98/$04.00 0 Copyright 1998, American Society for Microbiology Controlled Clinical Laboratory Comparison of Two Supplemented

More information

2015 EDITION. Selection. Publications. FAN Plus Media

2015 EDITION. Selection. Publications. FAN Plus Media 2015 EDITION of Selection Publications FAN Plus Media INTRODUCTION biomérieux solutions for diagnosing bloodstream infections and sepsis. Sepsis, a systemic inflammation due to infection, can lead to severe

More information

Controlled Clinical Comparison of the BacT/ALERT FN and the Standard Anaerobic SN Blood Culture Medium

Controlled Clinical Comparison of the BacT/ALERT FN and the Standard Anaerobic SN Blood Culture Medium JOURNAL OF CLINICAL MICROBIOLOGY, Oct. 2004, p. 4581 4585 Vol. 42, No. 10 0095-1137/04/$08.00 0 DOI: 10.1128/JCM.42.10.4581 4585.2004 Copyright 2004, American Society for Microbiology. All Rights Reserved.

More information

Effect of Blood Dilution on Recovery of Organisms from Clinical Blood Cultures in Medium Containing Sodium Polyanethol Sulfonate

Effect of Blood Dilution on Recovery of Organisms from Clinical Blood Cultures in Medium Containing Sodium Polyanethol Sulfonate JOURNAL OF CLINICAL MICROBIOLOGY, Feb. 1979, p. 248-252 Vol. 9, No. 2 0095-1137/79/02-0248/05$02.00 Effect of Blood Dilution on Recovery of Organisms from Clinical Blood Cultures in Medium Containing Sodium

More information

Blood cultures. Sept 2013 A/Prof John Ferguson (nepal)

Blood cultures. Sept 2013 A/Prof John Ferguson  (nepal) Blood cultures Sept 2013 A/Prof John Ferguson jferguson@hnehealth.nsw.gov.au www.hicsiganz.org (nepal) Clinical importance Diagnostic : Establishes or confirms the infectious aetiology Provides susceptibility

More information

Assessment of the BacT/Alert blood culture system: rapid bacterernia diagnosis with loading throughout the 24 h

Assessment of the BacT/Alert blood culture system: rapid bacterernia diagnosis with loading throughout the 24 h ORIGINAL ARTICLE Assessment of the BacT/Alert blood culture system: rapid bacterernia diagnosis with loading throughout the 24 h Jonas Bengtsson, Martin Wahl and Peter Lursson Department of Infectious

More information

(e.g., staphylococci, streptococci, and members of the family

(e.g., staphylococci, streptococci, and members of the family JOURNAL OF CLINICAL MICROBIOLOGY, June 1992, p. 1462-1468 95-1137/92/61462-7$2./ Copyright 1992, American Society for Microbiology Vol. 3, No. 6 Critical Assessment of Blood Culture Techniques: Analysis

More information

(e.g., staphylococci, streptococci, and members of the family

(e.g., staphylococci, streptococci, and members of the family JOURNAL OF CLINICAL MICROBIOLOGY, June 1992, p. 1462-1468 95-1137/92/61462-7$2./ Copyright 1992, American Society for Microbiology Vol. 3, No. 6 Critical Assessment of Blood Culture Techniques: Analysis

More information

has been developed for use with the instrument. In the present study, the performance of the Pedi-BacT system was

has been developed for use with the instrument. In the present study, the performance of the Pedi-BacT system was JOURNAL OF CLINICAL MICROBIOLOGY, Apr. 1993, p. 793-797 0095-1137/93/040793-05$02.00/0 Copyright X) 1993, American Society for Microbiology Vol. 31, No. 4 Comparison of the BacT/Alert Pediatric Blood Culture

More information

IV Catheter-Drawn Blood Cultures: Discarding the Initial Aliquot of Blood Does Not Reduce. Contamination Rates

IV Catheter-Drawn Blood Cultures: Discarding the Initial Aliquot of Blood Does Not Reduce. Contamination Rates JCM Accepts, published online ahead of print on July 00 J. Clin. Microbiol. doi:0./jcm.00-0 Copyright 00, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights Reserved.

More information

IV Catheter-Drawn Blood Cultures: Discarding the Initial Aliquot of Blood Does Not Reduce. Contamination Rates

IV Catheter-Drawn Blood Cultures: Discarding the Initial Aliquot of Blood Does Not Reduce. Contamination Rates JCM Accepts, published online ahead of print on July 00 J. Clin. Microbiol. doi:0./jcm.00-0 Copyright 00, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights Reserved.

More information

Clinical Laboratory Comparison of Lysis-Centrifugation and BACTEC Radiometric Blood Culture Techniques

Clinical Laboratory Comparison of Lysis-Centrifugation and BACTEC Radiometric Blood Culture Techniques JOURNAL OF CLINICAL MICROBIOLOGY, Nov. 1983, p. 1027-1031 0095-1137/83/111027-05$02.00/0 Copyright D 1983, American Society for Microbiology Vol. 18, No. 5 Clinical Laboratory Comparison of Lysis-Centrifugation

More information

Comparison of Recovery of Organisms from Blood Cultures Diluted 10% (Volume/Volume) and 20% (Volume/Volume)

Comparison of Recovery of Organisms from Blood Cultures Diluted 10% (Volume/Volume) and 20% (Volume/Volume) JOURNAL OF CLINICAL MICROBIOLOGY, May 1982, p. 860-864 0095-1137/82/050860-05$02.00/0 Vol. 15, No. 5 Comparison of Recovery of Organisms from Blood Cultures Diluted 10% (Volume/Volume) and 20% (Volume/Volume)

More information

Update on Detection of Bacteremia and Fungemia

Update on Detection of Bacteremia and Fungemia CLINICAL MICROBIOLOGY REVIEWS, July 1997, p. 444 465 Vol. 10, No. 3 0893-8512/97/$04.00 0 Copyright 1997, American Society for Microbiology Update on Detection of Bacteremia and Fungemia LARRY G. REIMER,

More information

Applicable To Employees of the Gundersen Tri-County Hospital clinical laboratory and Gundersen Palmer Lutheran Hospitals and Clinics laboratories.

Applicable To Employees of the Gundersen Tri-County Hospital clinical laboratory and Gundersen Palmer Lutheran Hospitals and Clinics laboratories. Subject BACTEC 9050 Index Number Lab-8681 Section Laboratory Subsection Regional Clinic/Affiliate Hospital Laboratories Category Departmental Contact Blum, Rachel Last Revised 2/13/2017 References Required

More information

ENGLISH % w/v. REDOX 1 is dispensed with added CO 2. Components may be adjusted to meet performance criteria.

ENGLISH % w/v. REDOX 1 is dispensed with added CO 2. Components may be adjusted to meet performance criteria. VersaTREK REDOX 1 80 ml with Stir Bar, 7102-44 VersaTREK REDOX 2 80 ml, 7103-44 VersaTREK REDOX 1 EZ Draw 40 ml with Stir Bar, 7106-44 VersaTREK REDOX 2 EZ Draw 40 ml, 7107-44 VersaTREK Connector, 7150-44

More information

Education of phlebotomy teams improves blood volume in blood culture bottles

Education of phlebotomy teams improves blood volume in blood culture bottles JCM Accepts, published online ahead of print on 26 December 2012 J. Clin. Microbiol. doi:10.1128/jcm.03068-12 Copyright 2012, American Society for Microbiology. All Rights Reserved. 1 2 3 4 5 6 7 8 9 10

More information

ROBERT L. COX' sooner than did SPB without sucrose (32). that the effect of sucrose is medium dependent. (29). To determine whether it also depends on

ROBERT L. COX' sooner than did SPB without sucrose (32). that the effect of sucrose is medium dependent. (29). To determine whether it also depends on JOURNAL OF CLINICAL MICROBIOLOGY, June 1983, p. 1045-1049 0095-1137/83/061045-05$02.00/0 Vol. 17, No. 6 Controlled Evaluation of Hypertonic Sucrose Medium at a 1:5 Ratio of Blood to Broth for Detection

More information

The Cat s Out of the Bag: Microbiological Investigations of Acute Transfusion Reactions.

The Cat s Out of the Bag: Microbiological Investigations of Acute Transfusion Reactions. The Cat s Out of the Bag: Microbiological Investigations of Acute Transfusion Reactions. Philippe Lagacé-Wiens, MD FRCPC, DTM&H plagacewiens@sharedhealthmb.ca COI declaration I have no conflicts, real

More information

Ministry Saint Michael s Hospital Laboratory LABORATORY POLICY AND PROCEDURE

Ministry Saint Michael s Hospital Laboratory LABORATORY POLICY AND PROCEDURE Ministry Saint Michael s Hospital Laboratory LABORATORY POLICY AND PROCEDURE TITLE/SUBJECT: FILE NUMBER: ASSIGNED MANUAL: ORIGINATION DATE: 1/24/08 Blood Culture Collection MB013.05 Phlebotomy Manual and

More information

An audit on the technique of collection of blood for culture at the National Hospital of Sri Lanka

An audit on the technique of collection of blood for culture at the National Hospital of Sri Lanka Research article An audit on the technique of collection of blood for culture at the National Hospital of Sri Lanka Abstract Enoka Corea 1, Nasra Ameen 1, Sanath Rajakaruna 1, Philomina Chandrasiri 2 Sri

More information

A COMPARISON OF COSTS AND EFFECTIVENESS OF THE BACTEC NR-730 SYSTEM AND A CONVENTIONAL METHOD OF BLOOD CULTURE.

A COMPARISON OF COSTS AND EFFECTIVENESS OF THE BACTEC NR-730 SYSTEM AND A CONVENTIONAL METHOD OF BLOOD CULTURE. A COMPARSON OF COSTS AND EFFECTVENESS OF THE BACTEC NR-730 SYSTEM AND A CONVENTONAL METHOD OF BLOOD CULTURE. G Kumarasinghe l, Carol Chow l and DCJ Bassett 2 Microbiology Division, Department of Laboratory

More information

Blood Culture Collection: Greiner Bio-One contributes to assure Best Practice. Your Power for Health. Gabriele Castelo-Rose.

Blood Culture Collection: Greiner Bio-One contributes to assure Best Practice. Your Power for Health. Gabriele Castelo-Rose. Your Power for Health Blood Culture Collection: Greiner Bio-One contributes to assure Best Practice Gabriele Castelo-Rose Greiner Bio-One GmbH Bad Haller Straße 32 A-4550 Kremsmünster Phone: (+43) 75 83

More information

Unique patient demographic identifiers: Name, Date of Birth (DOB), medical record number (MRN), Social security number (SS#)

Unique patient demographic identifiers: Name, Date of Birth (DOB), medical record number (MRN), Social security number (SS#) I. Purpose of Procedure (Principle) To standardize the process for obtaining the maximum volume (up to 20 milliliters) of blood from a patient for Blood culture testing while observing aseptic technique.

More information

Blood Collection for Cultures S: 2105 COLL v15

Blood Collection for Cultures S: 2105 COLL v15 Department Laboratory/Nursing Laboratory Laboratory System Site(s) All Sites Section Collection Document # S:2105 COLL V15 Subject BLOOD COLLECTION FOR CULTURES (BACTERIAL, FUNGAL, VIRAL) Purpose Ensure

More information

Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device

Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device Clinical Infectious Diseases MAJOR ARTICLE Reduction in Blood Culture Contamination Through Use of Initial Specimen Diversion Device Mark E. Rupp, 1 R. Jennifer Cavalieri, 1 Cole Marolf, 1 and Elizabeth

More information

Time for a culture change? Suboptimal compliance with blood culture standards at a district hospital in Cape Town

Time for a culture change? Suboptimal compliance with blood culture standards at a district hospital in Cape Town Time for a culture change? Suboptimal compliance with blood culture standards at a district hospital in Cape Town M S Abrahams, MB ChB; A C Whitelaw, MB BCh, MSc, FCPath (SA) (Micro); H Orth, MB ChB, MMed

More information

Culture negative endocarditis- an approach to laboratory diagnosis. Dr Shradha Subedi Microbiology Registrar Westmead Hospital, Sydney, NSW

Culture negative endocarditis- an approach to laboratory diagnosis. Dr Shradha Subedi Microbiology Registrar Westmead Hospital, Sydney, NSW Culture negative endocarditis- an approach to laboratory diagnosis Dr Shradha Subedi Microbiology Registrar Westmead Hospital, Sydney, NSW Definition and epidemiology Infective endocarditis (IE), whereby

More information

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT IN THIS SECTION MICROBIOLOGY TESTING Microbial assays involve a variety of tests, from the determination of the numbers and types of organisms naturally present

More information

Advantage of Combining Resin with Lytic BACTEC Blood Culture Media

Advantage of Combining Resin with Lytic BACTEC Blood Culture Media JOURNAL OF CLINICAL MICROBIOLOGY, Oct. 1997, p. 2634 2638 Vol. 35, No. 10 0095-1137/97/$04.00 0 Copyright 1997, American Society for Microbiology Advantage of Combining Resin with Lytic BACTEC Blood Culture

More information

Page72. Research Article

Page72. Research Article Page72 e-issn: 2249-622X Research Article Impact of Blood Cultures Drawn by Phlebotomy on Contamination Rates and Health Care Costs in the ICU ward of a Tertiary Hospital Anila A. Mathews, B. Appalaraju,

More information

Automated screening of blood cultures with the

Automated screening of blood cultures with the J Clin Pathol 1988;41:671-675 Automated screening of blood cultures with the Malthus microbiological growth analyser D F J BROWN, M WARNER, C E D TAYLOR, R E WARREN Clinical Microbiology and Public Health

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Section: Laboratory Version No. # 1.0 Initials: Revision Date: 20 April 2011 Title: 2.1B Processing of Blood Cultures_BacT/ALERT 1. Definitions 1.1. CRF- Case Report Form 2.

More information

Blood cultures: past, present and future. Dr Natalia Solomon MD, FRCPSC Medical Microbiologist DynaLIFE Dx

Blood cultures: past, present and future. Dr Natalia Solomon MD, FRCPSC Medical Microbiologist DynaLIFE Dx Blood cultures: past, present and future Dr Natalia Solomon MD, FRCPSC Medical Microbiologist DynaLIFE Dx Faculty/ Presenter Disclosure Faculty: Dr Natalia Solomon Relationships with commercial interests:

More information

Reducing blood culture contamination by a simple information intervention. Department of Medical Microbiology, Skåne University Hospital, Sweden

Reducing blood culture contamination by a simple information intervention. Department of Medical Microbiology, Skåne University Hospital, Sweden JCM Accepts, published online ahead of print on September 0 J. Clin. Microbiol. doi:./jcm.00- Copyright 0, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights Reserved.

More information

Detection of Bacteremia by Difco ESP Blood Culture System

Detection of Bacteremia by Difco ESP Blood Culture System JOURNAL OF CLINICAL MICROBIOLOGY, Mar. 1994, p. 811-818 0095-1137/94/$04.00+0 Copyright C) 1994, American Society for Microbiology Vol. 32, No. 3 Detection of Bacteremia by Difco ESP Blood Culture System

More information

Supplement. Guideline for Investigation of Suspected Transfusion Transmitted Bacterial Contamination. Canada Communicable Disease Report

Supplement. Guideline for Investigation of Suspected Transfusion Transmitted Bacterial Contamination. Canada Communicable Disease Report CCDR Canada Communicable Disease Report ISSN 1188-4169 Volume: 34S1 January 2008 Supplement Guideline for Investigation of Suspected Transfusion Transmitted Bacterial Contamination Suggested citation:

More information

Microorganisms in Blood Cultures

Microorganisms in Blood Cultures JOURNAL OF CLINICAL MICROBIOLOGY, Mar. 980, p. 8-8 009-37/80/03-08/0$0.00/0 Vol., No. 3 Evaluation of Acridine Orange Stain for Detection of Microorganisms in Blood Cultures L. R. McCARTHY* AND J. E. SENNE

More information

Contamination of blood cultures during venepuncture: fact or myth?

Contamination of blood cultures during venepuncture: fact or myth? Postgrad Med J (1990) 66, 1053-1058 The Fellowship of Postgraduate Medicine, 1990 At our Mother's Knee Contamination of blood cultures during venepuncture: fact or myth? Eyal Shahar, Bat-Sheva Wohl-Gottesman

More information

WP8 Branka Bedenic, University Hospital Zagreb, Croatia Valentino D Onofrio, Jessa hospital and Hasselt University, Belgium

WP8 Branka Bedenic, University Hospital Zagreb, Croatia Valentino D Onofrio, Jessa hospital and Hasselt University, Belgium WP8 Branka Bedenic, University Hospital Zagreb, Croatia Valentino D Onofrio, Jessa hospital and Hasselt University, Belgium Inge Gyssens, Jessa hospital and Hasselt University and Radboud University Medical

More information

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces Test Organisms: Staphylococcus aureus (ATCC 6538) Enterobacter aerogenes (ATCC 13048) Pseudomonas aeruginosa

More information

Isopropyl Alcohol Compared with Isopropyl Alcohol plus Povidone-Iodine as Skin. Preparation for Preventing Blood Culture Contamination ACCEPTED

Isopropyl Alcohol Compared with Isopropyl Alcohol plus Povidone-Iodine as Skin. Preparation for Preventing Blood Culture Contamination ACCEPTED JCM Accepts, published online ahead of print on 29 October 2008 J. Clin. Microbiol. doi:10.1128/jcm.01425-08 Copyright 2008, American Society for Microbiology and/or the Listed Authors/Institutions. All

More information

Microbiology for Oral and Topical Products - The basics Scott Colbourne Business Manager NSW ALS Food & Pharmaceutical

Microbiology for Oral and Topical Products - The basics Scott Colbourne Business Manager NSW ALS Food & Pharmaceutical Microbiology for Oral and Topical Products - The basics Scott Colbourne Business Manager NSW ALS Food & Pharmaceutical RIGHT S O L U T I O N S RIGHT PARTNER Contents TGO 77 - Introduction Tests Performed

More information

Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer

Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer Test Organisms: Staphylococcus aureus (ATCC 6538) Enterobacter aerogenes (ATCC 13048) Pseudomonas aeruginosa (ATCC 15442) Methicillin Resistant

More information

GUIDE TO INSPECTIONS OF MICROBIOLOGICAL PHARMACEUTICAL QUALITY CONTROL LABORATORIES

GUIDE TO INSPECTIONS OF MICROBIOLOGICAL PHARMACEUTICAL QUALITY CONTROL LABORATORIES GUIDE TO INSPECTIONS OF MICROBIOLOGICAL PHARMACEUTICAL QUALITY CONTROL LABORATORIES Note: This document is reference material for investigators and other FDA personnel. The document does not bind FDA,

More information

HardyVal TM CSP RANDOM TEST KIT

HardyVal TM CSP RANDOM TEST KIT HardyVal TM CSP RANDOM TEST KIT Cat. no. HVR1 Random Test Kit 5 tests/kit INTENDED USE Each kit contains: Tryptic Soy Broth, Double Strength (DS), 12ml Syringe, 5.2ml Whirl-Pak Bag Results Log Sheet 5

More information

/01/$ DOI: /JCM Copyright 2001, American Society for Microbiology. All Rights Reserved.

/01/$ DOI: /JCM Copyright 2001, American Society for Microbiology. All Rights Reserved. JOURNAL OF CLINICAL MICROBIOLOGY, Mar. 2001, p. 983 989 Vol. 39, No. 3 0095-1137/01/$04.00 0 DOI: 10.1128/JCM.39.3.983 989.2001 Copyright 2001, American Society for Microbiology. All Rights Reserved. Controlled

More information

CHAPTER 24. Immunology

CHAPTER 24. Immunology CHAPTER 24 Diagnostic i Microbiology and Immunology Growth-Dependent Diagnostic Methods Isolation of Pathogens from Clinical Specimens Proper sampling and culture of a suspected pathogen is the most reliable

More information

Today s Topics. General Quality Control Best Practices. Practices Antimicrobial Effectiveness Testing(AET) Best Practices Environmental Isolates

Today s Topics. General Quality Control Best Practices. Practices Antimicrobial Effectiveness Testing(AET) Best Practices Environmental Isolates Laboratory Best Practices in QC Microbiology Today s Topics General Quality Control Best Practices Growth Promotion Testing (GPT) Best Practices Antimicrobial Effectiveness Testing(AET) Best Practices

More information

Isopropyl Alcohol Compared with Isopropyl Alcohol plus Povidone-Iodine as Skin Preparation for Prevention of Blood Culture Contamination

Isopropyl Alcohol Compared with Isopropyl Alcohol plus Povidone-Iodine as Skin Preparation for Prevention of Blood Culture Contamination JOURNAL OF CLINICAL MICROBIOLOGY, Jan. 2009, p. 54 58 Vol. 47, No. 1 0095-1137/09/$08.00 0 doi:10.1128/jcm.01425-08 Copyright 2009, American Society for Microbiology. All Rights Reserved. Isopropyl Alcohol

More information

Isopropyl Alcohol Compared with Isopropyl Alcohol plus Povidone-Iodine as Skin Preparation for Prevention of Blood Culture Contamination

Isopropyl Alcohol Compared with Isopropyl Alcohol plus Povidone-Iodine as Skin Preparation for Prevention of Blood Culture Contamination JOURNAL OF CLINICAL MICROBIOLOGY, Jan. 2009, p. 54 58 Vol. 47, No. 1 0095-1137/09/$08.00 0 doi:10.1128/jcm.01425-08 Copyright 2009, American Society for Microbiology. All Rights Reserved. Isopropyl Alcohol

More information

Clinical Comparison of Aerobic, Hypertonic, and Anaerobic

Clinical Comparison of Aerobic, Hypertonic, and Anaerobic JOURNAL OF CLINICAL MICROBIOLOGY, Mar. 1976, p. 281-286 Copyright C 1976 American Society for Microbiology Vol. 3, No. 3 Printed in U-SA. Clinical Comparison of Aerobic, Hypertonic, and Anaerobic Culture

More information

Int.J.Curr.Microbiol.App.Sci (2014) 3(10)

Int.J.Curr.Microbiol.App.Sci (2014) 3(10) ISSN: 2319-7706 Volume 3 Number 10 (2014) pp. 810-815 http://www.ijcmas.com Original Research Article Comparison of Tissue Culture plate method, Tube Method and Congo Red Agar Method for the detection

More information

ABC. Methods for Determining Bactericidal Activity of Antimicrobial Agents; Approved Guideline. Volume 19 Number 18

ABC. Methods for Determining Bactericidal Activity of Antimicrobial Agents; Approved Guideline. Volume 19 Number 18 M26-A ISBN 1-56238-384-1 September 1999 ISSN 0273-3099 Methods for Determining Bactericidal Activity of Antimicrobial Agents; Approved Guideline Volume 19 Number 18 Arthur L. Barry, Ph.D. William A. Craig,

More information

Automated methods in the Microbiology Lab-Issues and Troubleshooting! Presented By: Dr B. Oboudi

Automated methods in the Microbiology Lab-Issues and Troubleshooting! Presented By: Dr B. Oboudi In the name of GOD Automated methods in the Microbiology Lab-Issues and Troubleshooting! Presented By: Dr B. Oboudi Overview Background/history Plate streakers and Gram stainers Blood cultures Automated

More information

Catheter-related infections: practical aspects in 2003

Catheter-related infections: practical aspects in 2003 Catheter-related infections: practical aspects in 2003 A joint meeting of the Société Belge d'infectiologie et de Microbiologie Clinique / Belgische Vereniging voor Infectiologie en Klinische Microbiologie

More information

Antibiotic Susceptibility Testing (ABST/AST)

Antibiotic Susceptibility Testing (ABST/AST) Antibiotic Susceptibility Testing (ABST/AST) Goal Offer guidance to physicians in selecting effective antibacterial therapy for a pathogen in a specific body site. Performed on bacteria isolated from clinical

More information

ENVIRONMENTAL PARAMETERS OF GROWTH

ENVIRONMENTAL PARAMETERS OF GROWTH ENVIRONMENTAL PARAMETERS OF GROWTH The growth and survival of microorganisms are affected by the chemical and physical conditions of the external environment. Environmental factors which have significant

More information

Advantages in every dimension. BacT/ALERT 3D TB Culture

Advantages in every dimension. BacT/ALERT 3D TB Culture Advantages in every dimension BacT/ALERT 3D TB Culture 1. Instrumentation The BacT/Alert 3D system offers the most technologically advanced fully automated walk away microbial detection system presently

More information

GenMark Diagnostics. eplex BLOOD CULTURE IDENTIFICATION (BCID): DESIGNED TO IMPROVE PATIENT CARE AND CLINICAL OUTCOMES

GenMark Diagnostics. eplex BLOOD CULTURE IDENTIFICATION (BCID): DESIGNED TO IMPROVE PATIENT CARE AND CLINICAL OUTCOMES GenMark Diagnostics eplex BLOOD CULTURE IDENTIFICATION (BCID): DESIGNED TO IMPROVE PATIENT CARE AND CLINICAL OUTCOMES Association for Molecular Pathology (AMP) November 15, 2017 Agenda eplex: True Sample-to-Answer

More information

Biofilm Protocol Optimization For Pseudomonas aeruginosa. Introduction. Materials and Methods. Culture Media, Incubation Time, and Biofilm Measurement

Biofilm Protocol Optimization For Pseudomonas aeruginosa. Introduction. Materials and Methods. Culture Media, Incubation Time, and Biofilm Measurement Biofilm Protocol Optimization For Pseudomonas aeruginosa Culture Media, Incubation Time, and Biofilm Measurement Introduction In addition to the conventional arsenal of antibiotic resistance mechanisms

More information

Study Title Antibacterial Activity and Efficacy of KHG FiteBac Technology Test Substance Using a Suspension Time-Kill Procedure

Study Title Antibacterial Activity and Efficacy of KHG FiteBac Technology Test Substance Using a Suspension Time-Kill Procedure Study Title Antibacterial Activity and Efficacy of KHG FiteBac Technology Test Substance Using a Suspension Time-Kill Procedure Test Method ASTM International Method E2315 Assessment of Antimicrobial Activity

More information

Published Standards ISO General instructions for microbiological examination ISO Enumeration and detection of aerobic mesophilic bacteri

Published Standards ISO General instructions for microbiological examination ISO Enumeration and detection of aerobic mesophilic bacteri ISO Standards Cosmetics Microbiology TC 217 WG1 Joyce Beauchamp L OREAL USA Products, Inc. 2010 PCPC Microbiology Workshop ISO TC 217 WG1 Microbiological standards and limits Secretariat IRISI Secretary

More information

Irish Guideline for the Investigation of Blood Culture Samples

Irish Guideline for the Investigation of Blood Culture Samples Irish Guideline for the Investigation of Blood Culture Samples Authors Irish Society of Clinical Microbiologists Blood Culture Guideline Development Group. Representatives of Irish Society of Clinical

More information

Guidelines for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel

Guidelines for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel Guidelines for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel Purpose The Clinical Laboratory Improvement Amendments (CLIA), passed in 1988, establishes

More information

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS Specific control measures can be used to kill or inhibit the growth of microorganisms. A procedure which leads to the death of cells is broadly

More information

Approximately 20% of the responding CLSI membership whose hospitals had greater than 200 beds was performing antifungal testing.

Approximately 20% of the responding CLSI membership whose hospitals had greater than 200 beds was performing antifungal testing. Vol. 28 No. 14 Replaces M27-A2 Vol. 22 No. 15 Reference Method for Broth Dilution Antifungal Susceptibility Testing of Yeasts; Approved Standard Third Edition This document addresses the selection and

More information

Protocols for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel

Protocols for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel Protocols for Laboratory Verification of Performance of the FilmArray Blood Culture Identification (BCID) Panel Purpose The Clinical Laboratory Improvement Amendments (CLIA), passed in 1988, establishes

More information

PRINCIPLES AND EXPLANATION OF THE PROCEDURE

PRINCIPLES AND EXPLANATION OF THE PROCEDURE INSTRUCTIONS FOR USE PARTIALLY COMPLETED BOTTLED MEDIA BA-256665.03 Rev.: April 2013 For Laboratory Use Only BD Tryptic Soy Agar INTENDED USE BD Tryptic Soy Agar, provided in bottles, is a partially completed

More information

British Intestinal Failure Alliance (BIFA) Recommendation. Diagnosis of Catheter Related Blood Stream Infections (CRBSIs)

British Intestinal Failure Alliance (BIFA) Recommendation. Diagnosis of Catheter Related Blood Stream Infections (CRBSIs) British Intestinal Failure Alliance (BIFA) Recommendation Diagnosis of Catheter Related Blood Stream Infections (CRBSIs) Simon Lal, Paul Chadwick, Jeremy Nightingale and the BIFA Committee Aim This document

More information

Blood Cultures: A Primer. Highland Hospital Blood Culture Isolates, 1/06-6/06

Blood Cultures: A Primer. Highland Hospital Blood Culture Isolates, 1/06-6/06 Blood Cultures & Line Infections Infectious Diseases, Highland Hospital Blood Cultures: A Primer Definition o A bottle is not a culture Technique o Careful prep (CHG preferred) o 10-30 ml blood o Culture

More information

Lauren A. Darling1#, Ann M. Evans1, Kathleen A. Stellrecht1,2, Seela M. Nattanmai1,

Lauren A. Darling1#, Ann M. Evans1, Kathleen A. Stellrecht1,2, Seela M. Nattanmai1, JCM Accepted Manuscript Posted Online 20 September 2017 J. Clin. Microbiol. doi:10.1128/jcm.01185-17 Copyright 2017 American Society for Microbiology. All Rights Reserved. 1 JCM Letter to the Editor Submission

More information

Optimizing Breast Pocket Irrigation: An in Vitro Study and Clinical Implications

Optimizing Breast Pocket Irrigation: An in Vitro Study and Clinical Implications Cosmetic Optimizing Breast Pocket Irrigation: An in Vitro Study and Clinical Implications William P. Adams, Jr., M.D., W. Chad H. Conner, B.A., Fritz E. Barton, Jr., M.D., and Rod J. Rohrich, M.D. Dallas,

More information

MICROBIOLOGY AND INVASIVE FUNGAL INFECTION. Javier Pemán, MD, PhD. Mycology Unit, Hospital Univ. La Fe Valencia (Spain)

MICROBIOLOGY AND INVASIVE FUNGAL INFECTION. Javier Pemán, MD, PhD. Mycology Unit, Hospital Univ. La Fe Valencia (Spain) MICROBIOLOGY Mycology Unit, Hospital Univ. La Fe Valencia (Spain) AND INVASIVE FUNGAL INFECTION Javier Pemán, MD, PhD What tools we can offer to optimize antifungal treatment? From lab Bench to Bedside:

More information

BD Columbia CNA Agar with 5% Sheep Blood, Improved II

BD Columbia CNA Agar with 5% Sheep Blood, Improved II INSTRUCTIONS FOR USE READY-TO-USE PLATED MEDIA PA-257303.04 Rev.: Sep 2011 BD Columbia CNA Agar with 5% Sheep Blood, Improved II INTENDED USE BD Columbia CNA Agar with 5% Sheep Blood, Improved II is a

More information

Medical Mycology. Lab (1)

Medical Mycology. Lab (1) Medical Mycology Lab (1) 1-Introduction Mycology - the study of fungi Fungi - molds and yeasts Molds - exhibit filamentous type of growth Yeasts - pasty or mucoid form of fungal growth 50,000 + valid species;

More information

Protocols for Laboratory Verification of Performance of the BioFire FilmArray Blood Culture Identification (BCID) Panel

Protocols for Laboratory Verification of Performance of the BioFire FilmArray Blood Culture Identification (BCID) Panel Protocols for Laboratory Verification of Performance of the BioFire FilmArray Blood Culture Identification (BCID) Panel A Laboratory Protocol for Use with Live s Purpose The Clinical Laboratory Improvement

More information

Relevance of Routine Use of the Anaerobic Blood Culture Bottle

Relevance of Routine Use of the Anaerobic Blood Culture Bottle JOURNAL OF CLINICAL MICROBIOLOGY, Aug. 2007, p. 2711 2715 Vol. 45, No. 8 0095-1137/07/$08.00 0 doi:10.1128/jcm.00059-07 Copyright 2007, American Society for Microbiology. All Rights Reserved. Relevance

More information

Rapid Detection of Bacterial Growth in Blood Cultures by Bioluminescent Assay of Bacterial ATP

Rapid Detection of Bacterial Growth in Blood Cultures by Bioluminescent Assay of Bacterial ATP JOURNAL OF CLINICAL MICROBIOLOGY, Sept. 1983, p. 521-525 0095-1137/83/090521-05$02.00/O Copyright C 1983, American Society for Microbiology Vol. 18, No. 3 Rapid Detection of Bacterial Growth in Blood Cultures

More information

Direct Susceptibility Testing with Positive BacT/Alert Blood Cultures by Using MicroScan Overnight and Rapid Panels

Direct Susceptibility Testing with Positive BacT/Alert Blood Cultures by Using MicroScan Overnight and Rapid Panels JOURNAL OF CLINICAL MICROBIOLOGY, July 1998, p. 2052 2056 Vol. 36, No. 7 0095-1137/98/$04.00 0 Copyright 1998, American Society for Microbiology. All Rights Reserved. Direct Susceptibility Testing with

More information

Direct Susceptibility Testing with Positive BacT/Alert Blood Cultures by Using MicroScan Overnight and Rapid Panels

Direct Susceptibility Testing with Positive BacT/Alert Blood Cultures by Using MicroScan Overnight and Rapid Panels JOURNAL OF CLINICAL MICROBIOLOGY, July 1998, p. 2052 2056 Vol. 36, No. 7 0095-1137/98/$04.00 0 Copyright 1998, American Society for Microbiology. All Rights Reserved. Direct Susceptibility Testing with

More information

Direct Susceptibility Testing with Positive BacT/Alert Blood Cultures by Using MicroScan Overnight and Rapid Panels

Direct Susceptibility Testing with Positive BacT/Alert Blood Cultures by Using MicroScan Overnight and Rapid Panels JOURNAL OF CLINICAL MICROBIOLOGY, July 1998, p. 2052 2056 Vol. 36, No. 7 0095-1137/98/$04.00 0 Copyright 1998, American Society for Microbiology. All Rights Reserved. Direct Susceptibility Testing with

More information

Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions References...

Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions References... Vol. 28 No. 12 Replaces MM18-P Vol. 27 No. 22 Interpretive Criteria for Identification of Bacteria and Fungi by DNA Target Sequencing; Approved Guideline Sequencing DNA targets of cultured isolates provides

More information

Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs. BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling

Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs. BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling WHITEPAPER Hyaluron Contract Manufacturing Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling Introduction The advent

More information

Environmental Surveillance FIDSSA Dr Ben Prinsloo Medical Microbiologist

Environmental Surveillance FIDSSA Dr Ben Prinsloo Medical Microbiologist Environmental Surveillance FIDSSA 2015 Dr Ben Prinsloo Medical Microbiologist The Scientist A scientist, in a broad sense, is a person engaging in a systematic activity to acquire knowledge We require

More information

Comparison of MicroScan WalkAway and VITEK Legacy Systems for a High-Volume Reference Laboratory

Comparison of MicroScan WalkAway and VITEK Legacy Systems for a High-Volume Reference Laboratory Comparison of MicroScan WalkAway and VITEK Legacy Systems for a High-Volume Reference Laboratory Merry Mariano Memphis Pathology Laboratory 5846 Distribution Drive Memphis, TN 38141 Answers for life. Introduction

More information

Testing the Effectiveness of Antiseptics and Disinfectants *

Testing the Effectiveness of Antiseptics and Disinfectants * OpenStax-CNX module: m58856 1 Testing the Effectiveness of Antiseptics and Disinfectants * OpenStax This work is produced by OpenStax-CNX and licensed under the Creative Commons Attribution License 4.0

More information

ENVIRONMENTAL PARAMETERS OF GROWTH

ENVIRONMENTAL PARAMETERS OF GROWTH ENVIRONMENTAL PARAMETERS OF GROWTH The growth and survival of microorganisms are affected by the chemical and physical conditions of the external environment. Environmental factors which have significant

More information

BD Mac Conkey II Agar / Columbia CNA Agar with 5% Sheep Blood (Biplate)

BD Mac Conkey II Agar / Columbia CNA Agar with 5% Sheep Blood (Biplate) PA-254447.02-1 - INSTRUCTIONS FOR USE READY-TO-USE PLATED MEDIA PA-254447.02 Rev.: Sep 2011 BD Mac Conkey II Agar / Columbia CNA Agar with 5% Sheep Blood (Biplate) INTENDED USE BD Mac Conkey II Agar /

More information

Microbiology Clinical Practicum Objectives - CLS 643

Microbiology Clinical Practicum Objectives - CLS 643 Microbiology Clinical Practicum Objectives - CLS 643 Based on your practicum location, you may or may not have the opportunity to perform all the functions in mycobacteriology, parasitology, and mycology.

More information

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS Specific control measures can be used to kill or inhibit the growth of microorganisms. A procedure which leads to the death of cells is broadly

More information

Mycobacterial transport medium for routine culture of fine needle aspiration biopsies

Mycobacterial transport medium for routine culture of fine needle aspiration biopsies Mycobacterial transport medium for routine culture of fine needle aspiration biopsies C A Wright, A Vermaak Divisions of Anatomical Pathology, Department of Pathology, Stellenbosch University and NHLS

More information