This standard covers the selection, installation and operation of loading and unloading metering systems.

Size: px
Start display at page:

Download "This standard covers the selection, installation and operation of loading and unloading metering systems."

Transcription

1 Manual of Petroleum Measurement Standards Chapter 6 Liquid Flow Measurement Systems Section 2A Truck and Rail Loading and Unloading Measurement Systems DRAFT FIRST EDITION 3_24_2016

2 FOREWORD This standard covers the selection, installation and operation of loading and unloading metering systems.

3 Table of Contents To be added in editorial.

4 Introduction This standard serves as a guide in the selection, installation and operation of truck and rail, loading and unloading measurement systems. This section does not cover truck and rail mounted flow meters. This standard does not endorse or advocate the preferential use of any specific type of metering system or meter. In general, metering system installations should meet certain fundamental requirements, including those that ensure proper meter type, size, installation and adequate protective and readout devices (such as presets, registers [counters], strainers, relief valves, pressure and flow control valves, and air eliminators, where required). Descriptions of these and other system components are covered elsewhere in this standard or other API standards. Also, to ensure compliance with state laws and regulations the latest editions of NIST Handbook 44, Handbook 12, as well as specific local weights and measures requirements, should be considered.

5 Chapter 6 Liquid Flow Measurement Systems Section 2A Truck and Rail Loading and Unloading Measurement Systems 1 Scope This standard (section 6.2A) is part of a set of documents which detail the minimum requirements for the design, selection, and operation of truck and rail loading and unloading metering systems for single phase liquid hydrocarbons. 1.1 Field of Application Sections of Chapter 6 describe metering system design. Section 6.1A describes the general considerations applicable to all metering systems and shall be consulted together with this section, Section 6.2A, when designing systems. For the purpose of Chapter 6.2A, the equipment which is covered as part of a truck or rail, loading or unloading meter system will be limited to that which is necessary for the proper operation, calibration and performance of the primary, secondary and tertiary devices as well as equipment that can affect the agreement between the ticketed (also called quantity transaction record, batch ticket, or measurement ticket) and delivered quantity. When aspects are covered under the scope of other chapters of the API Manual of Petroleum Measurement Standards, and to avoid replication and conflict, they are not covered by this standard. In these cases, this standard provides limited information and refers the user to those chapters. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. API Manual of Petroleum Measurement Standards (MPMS), Chapter 4.6, Pulse Interpolation API Manual of Petroleum Measurement Standards (MPMS), Chapter 5.2, Measurement of Liquid Hydrocarbons by Displacement Meter API Manual of Petroleum Measurement Standards (MPMS), Chapter 5.6, Measurement of Liquid Hydrocarbons by Coriolis Meters API Manual of Petroleum Measurement Standards (MPMS), Chapter 6.6, Pipeline Metering Systems API Manual of Petroleum Measurement Standards (MPMS), Chapter 11.1, Physical Properties Data API RP 2003, Protection against Ignitions Arising Out of Static, Lightning, and Stray Currents NIST Handbook 44, Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. Terms of more general use may be found in the API MPMS Chapter 1 Online Terms and Definitions Database. 3.1 transloading the transfer of a commodity from one mode of transportation to another mode of transportation. An example of transloading is when a commodity is transferred from a truck into a railcar. 3.2 preset controller(s) A set of electronic equipment and/or software that is adjusted/configured beforehand to facilitate installation and use. Measurement presets implements algorithms using analog and digital signals received from meters, temperature transmitters, pressure transmitters, and density transmitters to calculate volumes at base conditions. These are sometimes referred to as preset, electronic preset, preset counter, batch controller, or preset instrument.

6 3.3 Terminal Automation Systems (T.A.S.) comprehensive programs with human machine interface (HMI) that manages a facility s commodities movements, inventory control, and reconciliation through automation. 4 Loading, Unloading, and Transloading Metering Systems 4.1 General The loading, unloading, and transloading metering systems described in this standard are those that apply to transport-type truck and rail facilities. These measurement systems (including for example all devices addressed in Chapter 6.2A) should be designed to accommodate the full range of process conditions to be encountered. The design of the system should allow one meter to be proved without interfering with the other meters involved in the loading operations. Different than truck loading and unloading metering systems which can only handle a single truck; multiple rail cars can be loaded simultaneously. Simultaneous loading or unloading of multiple rail cars through a single meterbank will result in a single quantity determination which represents the quantity transferred for all of the cars. Having a single ticket representing multiple rail cars can cause issue when reporting requirements, perhaps from government or regulation, dictate individual bills of lading. The configuration and count of rail car metering systems may require an evaluation of the ticket requirements. Options for rail unloading and loading metering systems may require a combination of the following data sources: 1. Quantity determination a. Meter run dedicated to each rail car (quantity determined per car) b. Meter run(s) dedicated to a string of rail cars (quantity determined per string of cars) 2. Quality determination (e.g. Density or S&W) a. Sampler dedicated to each car (determination per car) b. Sampler dedicated to a series of rail cars c. Sampler dedicated to a predetermined batch volume for a rail movement Note other local or national regulations or guidelines could apply (for example, in the USA, Handbook 44). 4.2 Loading, Unloading, and Transloading Metering System Installation Loading, unloading, and transloading metering systems are intended to determine accurate quantities of products into or off of transport truck and rail cars. The metering configurations may consist of single product meters, blend meters and additive meters. Design, installation, and operation of the meter system is extremely important because meter volumes are considered in custody transfer and loss/gain determination. Note that the loading and unloading system is usually the final opportunity to measure accurately, i.e., after the product leaves the loading and/or unloading facility, measurement errors are difficult to correct. Considerations for proving equipment should be taken into account during design and installation. See 8.1 of this document for additional information about proving. 4.2 Loading operation Top Loading Because State and Federal regulations govern the release of hydrocarbon emissions to the atmosphere, some forms of top loading may not be acceptable. Personnel safety should be considered in top loading system design.

7 Top loading (see Figure 1) uses an overhead-loading arm to reach the loading dome hatches on the truck and railcars. The loading arm should be in the same state of fill either void or full at the beginning and end of the loading operation to ensure measurement consistency. Figure 1 Installation Diagram Metered Truck and Railcar Loading (Top Loading) Top loading arms that have been designed to be completely empty when not in use should be equipped with a manual or automatic vacuum breaker located at the high point in the piping and downstream of the loading valve. This provision allows the arm and drop tube to drain after the loading valve is closed preventing product from being retained in the arm and unintentionally being delivered with the next batch. Meters for top loading systems can be located on the loading platform or near the ground. When the meter is located below the platform, consider locating the meter register and/or preset to facilitate the reading of quantities by the loader. A preset device, either local or remote, may be installed in any loading system to expedite loading operations Bottom Loading There are no measurement concerns related to bottom loading. See figure 2 for a typical installation.

8 Figure 2 Installation Diagram Metered Truck and Railcar Loading (Bottom Loading) 4.3 Unloading While unloading systems use many of the same components associated with loading there are some special considerations that need to be addressed for proper measurement. The typical components of an offloading system are a meter, a pump, an air eliminator, strainers, check valves, and proving connections. 4.4 Transloading While transloading systems use many of the same components associated with loading there are some special considerations that need to be addressed for proper measurement. The typical components of a transloading system are a meter, a pump, an air eliminator, strainers, check valves, and proving connections. This system may be a permanent installation or portable. When a portable system is used there are additional things to consider. When installing transloading systems it is important to mitigate any system interference, the metering device s operating principles should be considered and appropriate precaution should be observed.

9 4.5 Loading And unloading Accessories Strainers and Filters Suspended solids in the fluid being measured can cause inaccuracy and even damage metering equipment. Solid particulates should be prevented from reaching the meter by using an appropriate strainer or filter per meter manufacturer s recommendations. Filters are typically utilized in jet fuel, bio-fuels and distillate applications in lieu of strainers. The strainer or filter should be monitored and/or checked periodically to avoid restricting flow which could lead to vaporization, or reduce the normal flow rate and thereby affect accuracy by causing the system to deviate from the flow conditions when the metering system was proved Air Eliminators Air eliminators are required in systems where air or vapor can be introduced into the system. If not eliminated, air will adversely affect measurement and may cause damage. Additional information is available in Annex A of this chapter. If air eliminators are installed, they should be installed upstream of the meter, and their purpose is to dispose of any air or vapor in the delivery line before it passes through the meter. If a system is designed so that significant amounts of air, vapor, or both cannot be introduced, an air eliminator is not required. A sight glass can be located between the air eliminator and the flow meter to check the functionality of the air eliminator and to ensure the piping between the unloading arm coupler and meter is always full of product Insulation or heat tracing Unique properties of the petroleum or petroleum product(s) being measured may require the individual components or the entire system to be insulated and/or heated. The purpose of the insulation or heat trace is to preserve the process conditions. For example, high viscosity crude oil which is heated to increase Reynolds number. Another example could be a low temperature commodity such as light liquid hydrocarbon (LLH), cooled below vapor pressure. Measurement of such commodities outside their desired state may impact measurement performance Thermal Relief Systems Due to the need for thermal relief systems to have an open flow path to a lower pressure location and that thermal relief valves do not provide positive isolation, thermal relief valves can directly affect measurement accuracy if they are located between the meter and the prover, or between the meter and the transport Vents Liquid metering systems shall be designed with the necessary facilities to handle vapors and non-condensable gases ( gases ) when they are (1) trapped within the piping, (2) introduced from the incoming flowing stream or (3) formed due to flashing of the liquid. When not addressed gases within a liquid metering system may cause equipment damage as well as inaccurate measurement and calibration. Metering system designs should provide a means to remove gases and vapor, e.g. a vent, from any areas where they could become trapped. With vent taps comes the potential for leakage or spill-over. If vents are located upstream of the meter and prover or downstream of the meter and prover then leaks and spill-over could cause a difference between the balance of the quantity transferred and the quantity ticketed. If vents are located between the meter and prover, any leaks or spill-over could affect the measurement accuracy. If a vent or tap that cannot be avoided by improving the piping configuration, a means of positive shut off shall be provided at each vent tap point.

10 If gases are intermittently introduced into the incoming, flowing stream a high point vent will not provide a solution unless it is combined with an air eliminator to trap the gas and a valve to release it based on liquid level. (Refer to MPMS Chapter 6.1) High point vents should not be used as a solution to gases formed from continuous flashing or cavitation. Gases formed by continuous flashing or cavitation should be solved by maintaining adequate back pressure. (refer to paragraph 6.1 Back Pressure Control.) Drains Metering system designs should include taps at low point locations such that liquids may be drained before maintenance. With drain taps comes the potential for leakage when they are not in use. When drain taps are located upstream of the meter and prover or downstream of the meter and prover then leaks could cause a mismatch between the quantity transferred and the quantity ticketed. When drains are located between the meter and prover and there are leaks or spill-over then the measurement accuracy will be affected due to erroneous calibrations. Any drain that can affect measurement accuracy or cause a difference between the quantities transferred and the ticketed quantity shall be equipped with a means to verify that no leaks exist Pumps System hydraulics can affect meter performance. System pumps and controls should be designed to meet the desired operation of the facility such that adequate pressure and flow are provided.. The ability to prime the pump and the effect of fluid properties, such as density and viscosity, should be considered when selecting pumps. The location of the pump relative to the meter should be considered if vibration or pulsation will affect the meter performance. If pumps are capable of pressure exceeding any equipment rating in the measurement system, over-pressure protections should be put in place. 4.6 Valves Isolation/Secondary Shutoff Valves Inlet/isolation valves are related to isolation, bypass and evacuation of piping associated with the measuring system. Each, given its respective position in the piping configuration and its operation, can have unintended consequences adversely affecting measurement if they present an opportunity for liquids to bypass the measuring elements (meters and associated instrumentation, including sampling systems) Check Valves Check valves are required to prevent backflow, siphoning with low tank head (low pressure), and cross contamination of product during blending applications. When choosing the proper check valve, consider pressure drop and slamming of the flapper, which can cause damage when the valve opens and closes. For unloading it is recommended to install a check valve on the discharge line. This will keep product from coming back from the tank when the pump is shut off. If the air elimination line is tied into the delivery line downstream of the meter it should have a check valve and some way of verifying the operation of the air eliminators product shut off functionality. These are necessary to prevent unmeasured product from flowing either direction and bypassing the meter Control Valves Control valves are used to control process variables such as flow or pressure by fully or partially opening or closing to achieve the desired conditions. A "set point" for process control to a process variable value may be provided manually, or by an automated process controller.

11 If control valves are used to maintain back pressure, they should be installed downstream of the meter. The control valve location should not negatively affect meter performance. Severe shock to loading systems can occur unless certain precautions are taken in the design of the delivery facilities, in the construction of the facilities, or in both. Closing the loading or control valve too rapidly may cause hydraulic shock which can damage or change the performance of the meter. This condition may be avoided by controlling the rate of closure of the valve involved. The use of slow-closing valves or the control of the rate of closure on the loading arms is recommended to reduce line shock. The occurrence and severity of line shock depend on flow rate, shutdown rate, and length and size of lines. When preset devices are used, a two-stage startup-and-shutdown valve should be incorporated to start the flow slowly before it allows full flow to develop and to slow the flow down shortly before the final shutoff. Additional information related this topic can be found in Annex XThe manufacturers recommended flow control range should not be exceeded. This could result in poor flow control, unsafe shutoff, inaccurate measurement, and premature wear. 5 Meters 5.1 General This section covers the characteristics of loading and unloading meters and discusses only those considerations unique to the design, selection, installation, and performance for chemicals, liquid hydrocarbons, and bio-fuels. Historically, truck and railcar loading and unloading systems were designed for use with displacement meters; however, technological advances and blending applications have encouraged the introduction of other meter designs such as turbine and Coriolis meters. When retrofitting existing displacement metering systems with turbine and Coriolis meters, care should be taken to ensure proper application of these technologies. API MPMS Chapter 5 defines the installation of meters. Make certain that any areas that may trap or build up with debris are avoided. Avoid installing the meter at a high point in the piping to prevent trapping air in pockets and causing mismeasurement. Metering systems can be used to determine the total quantity (volume, weight, or both) being loaded. Metering systems generally include a flow meter (either volumetric or mass), appropriate temperature and pressure instruments for compensation to standard reference conditions, and a flow computer to collect the instrument signals, perform the necessary calculations, and produce a final run ticket or quantity report. The meters and accessory equipment require periodic proving, calibration, or verification to ensure they are in good working order. See API MPMS Chapter 6.1A for additional information about accessory equipment. The frequency and tolerances are set by the manufacturer, equipment owner or contract terms. Specific guidance for tolerances is also provided within the applicable API standard. Refer to API MPMS Ch. 5 and API MPMS Ch Displacement Meters Displacement meters (API MPMS Ch. 5.2) will require some form of signal output, either electronic (preferred method) or mechanical. Meter readout adjustment methods are discussed in MPMS Chapter 5.2, Section Please note that when a meter originally furnished with a manual calibrator is retrofitted with an electronic pulse transmitter, the transmitter shall be mounted below the calibrator or the calibrator needs to be removed. Displacement meters typically can be mounted either vertically or horizontally. Consult the manufacturer for proper orientation to prevent issues related to bearing load and wear. Displacement meters do not require flow conditioning. See Figure 3 for a typical installation. Displacement meters should be considered for loading and unloading applications which present a wide variation in flow rate. This may be more critical when a single meter factor is used to represent the batch.

12 Figure 3 Typical Displacement Meter Loading Configuration 5.3 Turbine Meters The performance of turbine meters (API MPMS Ch. 5.3) is affected by erratic or inconsistent flow profile caused by upstream or downstream devices and obstructions, such as strainers, valves, pipe internal diameter irregularities. Fouling or plugging or a flow conditioner or meter will cause flow distortions and affect meter performance. Maintenance performed on the meter or flow conditioner to remove fouling or plugging requires that the meter be reproved. The influence on pressure drop/flow rate varies depending on the type of flow conditioning applied; this needs to be considered in the overall system design. For loading, unloading, and transloading systems turbine meters may be mounted either horizontally or vertically. Meter performance could be affected by installation orientation. Follow manufacturer s recommendation. See figure 4 for a typical installation.

13 Figure 4 Typical Turbine Meter Loading Configuration 5.4 Coriolis Meters For Coriolis meters (API MPMS Ch. 5.6) mounting orientation can cause unwanted effects. Any air in the sensing tubes will create errors in the measurement system. Consult with the manufacturer for specific installation requirements. Coriolis meters do not require flow conditioning (see Figure 5). A means should be provided to isolate the liquid full meter under no-flow conditions for zeroing purposes, in accordance with the API MPMS Ch Selection of a Coriolis meter in a loading or unloading application requires consideration of the proving method and/or the locally available portable provers. Consult both the meter manufacturer and the prover operator for assurances that the paring will work.

14 Figure 5 Typical Coriolis Meter Loading Configuration 5.5 Electrical Installation Truck and railcar loading, unloading, and transloading systems may include a variety of electrical and electronic accessories. The electrical system should be designed and installed to meet the manufacturers' recommendations, as well as any local, state, city, national, or company regulations as applicable. Noise inducement and signal interference with the meter pulse signal, which can adversely impact measurement, shall be avoided. The classification of the area should be known and understood in order to comply to any regulatory requirements. 5.6 Flow Rates Meters should be sized to accurately measure flow at minimum and maximum flow rates. All operational flow rates should be known so the metering device can be proved and calibrated correctly (Refer to section 8 of this document). For additional information on flow rates and their effects on operations refer to API RP 2610 and API RP 2003.

15 5.7 Pressure Drops The addition of a prover to the flow path will change the flow resistance. Depending on the pump selection and arrangement of parallel loading/unloading connections, the increased flow resistance may lower the flow rate on the meter being proved away from its normal operating rate and may affect the meter factor. 5.8 Orientation and location of meter Meter performance can be affected by installation orientation. Follow the manufacturer s recommendations for orientation. Flow meters s ho u l d be located as near as practicable to the rail car or tank truck being loaded or unloaded to mitigate the possibility of a partially full line. If the line is not completely full, the metered quantity might not match the loaded quantity. If the meter cannot be located in close proximity, the loading facility should have a procedure to ensure consistent line fill. Following a consistent procedure will ensure that errors between the metered quantity and the delivered quantity are not introduced. 5.9 Meter and control valve sizing All meters and control valves have minimum and maximum ranges with respect to both flow rate and pressure and should only be operated within these ranges. When designing or retrofitting a multiple arm loading system the system should be checked at the extremes of operation to assure that all meters stay within operational parameters no matter how many arms are operating. Consult the manufacturer s specifications for meter and valve sizing and recommendations. Final product recipe components can vary greatly in both the volume and rate that they are loaded. It is necessary to be certain that any recipe and the associated percentages of the components of the recipe fall within the linear and repeatable flow ranges of the meter and control valve Meter selection Meter sizing should be determined by, but not limited to manufacturer recommendations, turndown, linearity, viscosity range, flow conditions, pressure drop, and product composition. For additional information, refer to Chapter 5. Many loading and unloading systems are designed for typical maximum rates of between 500 and 700 GPM. For either bottom or top loading, it is desirable to start the load with a low flow condition to ensure adequate compartment head to minimize splashing, vaporization, and static electricity. If this is the case, the meter shall be sized to account for this low flow condition. 6 Auxiliary Meter Equipment 6.1 Back Pressure Control Conditions that contribute to flashing and/or cavitation of the liquid stream as it passes through the meter can be avoided through suitable system design and operation of the meter. Sufficient pressure within the meter can typically be accomplished by using control valves or back pressure valves. In the absence of a manufacturer's recommendation, the numerical value of the minimum pressure at the outlet of the meter may be calculated with the following expression, which has been commonly used. The calculated pressure has proven to be adequate in most applications, and it may be conservative for some situations. where P b» 2DP *P e (1) P b = minimum back pressure, pounds per square in. gauge (psig),

16 DP = pressure drop through the meter at the maximum operating flow rate for the liquid being measured, pounds per square in. (psi), P e = equilibrium vapor pressure of the liquid at the operating temperature, pounds per square in. absolute (psia), (gauge pressure plus atmospheric pressure). For additional information of back pressure control valves and/or control valves refer to section of this document. 6.2Temperature For type of temperature sensors, and, transmitters along with the temperature calibration, correction, and calculations refer to Chapter Location of Temperature Sensor The placement of the temperature sensor is critical to accurate temperature measurement. API MPMS Chapter 7 defines the sensor location and number of sensors required. The most common methods of performing automated temperature correction are outlined in the Preset Section 13 and Terminal Automation System Section 15. In both cases, it is important that the temperature measuring device is properly calibrated according to MPMS Ch Automatic Temperature Compensation Devices Mechanical Live Measurement of the temperature can be used but may result in increased uncertainty. 6.3 Pressure Pressure compensation is required whenever the loading and unloading meter is above atmospheric pressure. The pressure during proving operations and normal operations shall be accounted for. Refer to MPMS Chapter 6.1A and MPMS Chapter Since pressure affects the calculation results, a fixed CPL/CMF should not be allowed to be used if the delta pressure is outside of a user s tolerance. For LPG loading and unloading operations, pressure measurement is necessary for both meter proving and ticket volume determination Location of Pressure Measuring Device If correction for elevated meter pressure is required, the pressure measuring device shall be installed such that it does not interfere with the performance of the meter, but is representative of the pressure within the meter. The pressure measuring device can be either a pressure gauge or an electronic transmitter Calibration The pressure measuring device shall be verified on a periodic basis against a device that is traceable to a national standard. 7 Additive Measurement Additives shall be accounted for on the final ticket. This can be accomplished either by injecting the additive upstream of the custody transfer meter or by measuring the additive separately before injection. In multicompartment cars, it may be necessary to account for the additive injected into each compartment.

17 Injection of additives upstream of the main custody transfer meter is the typical configuration used for additive injection. It may require a higher injection pressure than downstream of the meter due to pressure loss through the meter. Depending on the meter technology applied, careful selection of the injection point may be required such that the location does not interfere with the product flow pattern. 8 Meter Proving 8.1 Methods The method used for proving loading and unloading meters will determine loading and unloading design requirements. In choosing a proving method factors such as time constraints, truck and rail lane dimensions, number of meters, and availability of product return lines should be considered. Refer to API MPMS Chapter 4 for proving requirements and to API MPMS Chapter 6.1A for additional references. The proving frequency may be based on throughput volume, time, weights and measures requirements, seasonal temperature changes, historical meter performance, a combination of these factors, or contractual requirements. In addition, meters should be re-proved when subjected to repairs or changes that may affect measurement accuracy. When using electronic presets with multiple flow rate configurations, the establishment of multiple meter factors may be required (see section 9). This is particularly true when low flow startup and shutdown sequences are employed to prevent system shock and static electricity generation (see API RP 2003). The meter should be proved as close as practical to the same conditions under which it normally operates. Care should be taken to ensure that the pressure drop created by the prover s piping, valves, and hoses, does not reduce the flow rate to an unacceptable level during proving. Caution should be exercised to ensure normal operating flow rates can be achieved through the entire proving system. Loading and unloading systems typically incorporate low flow startup and shutdown sequences to reduce static electricity (see API RP 2003) and system shock. These changes in flow rates can affect meter accuracy and are included in each calibration run. Due to the size difference of the prover and truck and rail compartments, the accuracy of the calculated meter factor may be adversely affected for meters with poor linearity. When meter linearity is not sufficient, it is recommended that meter factors be utilized to correct for inaccuracies for each operational flow rate (i.e., low and high flow rates). To help correct for the above inaccuracies the low flow rate factor should be established and applied prior to proving at the high rate Volumetric Provers (Tanks or Cans) The tank or can method provides a direct volumetric comparison between the meter under test and a national metrology-certified volumetric prover. Variables such as size, construction material, and design should be considered when selecting a volumetric prover. API MPMS 4.4 defines the criteria for volumetric provers. It is also important to ensure that normal operating conditions are reproduced during the proving process. Vapor recovery hoses and grounding equipment should be connected prior to beginning the process and flow rate stability should be achieved Displacement Provers Displacement provers can provide a convenient, accurate, and expeditious method for calibrating loading and unloading meters Displacement provers with 10,000 whole pulses or greater API MPMS Chapter 4.2 defines the pulse count requirements that are necessary for the prover to provide accurate proving calculations in accordance with API MPMS Chapter Displacement provers with less than 10,000 whole pulses (small volume prover) Displacement provers generating less than 10,000 whole pulses can be utilized for proving meters. API MPMS Chapter 4.6 defines the pulse interpolation techniques to be employed. These devices can be very compact and are conducive to proving directly into an awaiting delivery truck and rail. Meter factor determination is accomplished using the same requirements described in the above section.

18 8.1.3 Master Meters The master meter method involves the use of a master meter that has been calibrated prior to its use and will serve as a standard to determine the accuracy of another meter. API MPMS Chapter 4 defines use of master meters for proving. 8.2 Proving Conditions Loading and unloading meters should always be proved under the same conditions experienced during normal operation. These conditions include product composition (density and viscosity), flow rate, pressure, and operating temperature. Significant product temperature changes can affect meter accuracy and can necessitate additional meter proving to compensate for liquid density changes and dimensional changes to measurement equipment material. Inappropriately sized supply pumps or piping systems may cause a reduction in flow rate when multiple risers of the same product are in service. Special procedures may have to be developed to ensure that normal operating conditions are achieved during the proving process. In addition, normal operating parameters can require adjustment in order to ensure consistent flow rates during heavy demand periods. These procedures may include using multiple meter factors and step flow rate control to ensure meter accuracy during periods of varying flow rates. Another option is to limit the maximum loading flow rate at each loading arm to ensure stable flow rates during multiple lane demands. API MPMS Chapter 12 defines the corrections to be made for any changes in volume resulting from the differences in liquid temperatures between time of passage through the meter and time of volumetric determination in the prover. Refer to API MPMS Ch. 4.8 for additional information about operating a proving system including operating above vapor pressure when using displacement or master meter proving Proving When Transport is at Atmospheric Pressure When the normal custody transfers are made into a truck and rail car at 0 psig, and the loading and unloading design does not use pressure transmitters to correct the meter pressure to 0 psig, a composite meter factor will have to be applied to ensure system accuracy. This can be accomplished in either of two ways. 1. In the first method, both the meter and prover volumes are corrected to standard pressures (0 psig) while proving. The resulting meter factor is then multiplied by the liquid compressibility factor (CPL) of the meter (using nominal operating pressure), creating a composite meter factor to replicate the normal custody transfer. 2. In the second method, the meter pressure is disregarded while proving, with the resulting meter factor incorporating the CPL at the meter; however, if the prover is at a pressure other than zero then the prover volume is corrected to standard pressure to replicate the normal custody transfer. For both methods, meter pressure fluctuations should be negligible, so that the meter pressure effect will be consistent when making normal custody transfers and when proving Proving When Transport is above Atmospheric Pressure If the normal custody transfer is made into a truck or rail car and the meter pressure(s) are corrected to base conditions, both the meter and the prover volume are corrected to base conditions when proving (standard conditions). These conditions could require pressure measurement at both locations Proving of Blending Systems Blending systems generally incorporate an electronic preset or flow computer to control the process. The preset or flow computer measures the volume of each component and assures the proper mixture by automatically controlling

19 individual control valves. Today s electronic presets typically have the capability of applying multiple meter factors to correct for changes in flow rates and product type. Care should be taken to ensure that each loading scenario is understood and duplicated during meter proving Sequential Blending In order to ensure accuracy during this process, the single meter used for sequential blending will have to be proved for each product and at each flow rate. To help ensure homogeneous mixtures, systems may be configured to alternate the components in a sequence that divides the required volume of a single component into two stages to assist with mixing (e.g., for midgrade gasoline, the regular component volume can be divided into two separate stages: one before and one after the premium gasoline). During the blending operation each component product will typically cycle through low flow startup and shutdown and continuous high rates. These set points should be accounted for during meter proving Ratio Blending Because multiple products are simultaneously flowing during ratio blending, product measurement can be adversely affected by the piping configuration and flow control. Flow rates will at times vary during the loading process due to back pressure caused by competing streams. The electronic presets are configured to achieve a final mixture ratio and often will significantly reduce the flow rate for one stream to allow the other(s) to deliver the required quantity. When this occurs, individual meters can be subjected to substantially reduced flow rates, causing inaccurate measurement. Minimum and maximum flow rates should be determined to facilitate meter proving. The proving process should include all possible flow scenarios to help ensure accurate measurement. A method to address this issue is to use meter factor linearization Fall Back Flow Rate If operational conditions prevent the preset high flow rate from being achieved or maintained, a predetermined fallback flow rate may be applied. A fallback rate is applied to reduce the flow to a controllable level. This will ensure that the speed of operation of the loading valve is sufficient to prevent overfill. The number of flow rates can be adjusted to meet the particular installation requirements but normally would be set at decreasing flow rates between the programmed high and low rates. Once conditions permit, the electronic preset can automatically return to the desired flow rate. For configurations where a fallback flow rate is used, the meter should be calibrated at this fallback flow rate. 9 Meter Factor When a reduction in flow rate occurs due to operational conditions such as intermittent excessive pumping capacity demand, measurement accuracy can be adversely affected. For typical operations where flow rates may vary, it is advisable to prove the meter at multiple flow rates. At least two flow rates should be used: a slow flow rate for initial flow and a high flow rate at which the majority of product will be loaded. A meter factor linearization function in the electronic flow computer should be available to be configured to allow the preset to be able to select the meter factor closest to the flow rate being used or provide a meter factor linearization between two adjacent factors. 9.1 Sealing Metering Equipment All meter system accessories affecting the accuracy of volume measurement should be sealed, and all outlets or connections through which unmeasured withdrawal is possible should be sealed. Weights and measures regulatory agencies and NIST allow either electronic audit trails or sealable switches where electronic systems are installed. 9.2 Security API MPMS Chapter 21.2 defines the safeguards to be included to prevent improper changes to input variables which may affect measurement. A protect switch that safe guards relevant parameters, mechanical construction and/or an electronic audit trail should be utilized for this purpose. If a switch or mechanical means is utilized, then provisions should be provided that allow placement of seals or locks through the switch and the enclosure. The

20 program protection switch should make all parameters that affect measurement read only and inaccessible unless the seal is broken and this switch is activated. The electronics enclosure should not be accessible without first breaking the seal to visibly indicate violation of sealed status. If the audit trail method is utilized then the preset controller should be programmable to prompt for a unique password to select the programming of parameters. (For examples on audit trail implementation see API MPMS Chapter 21.2.) 10 Grounding Systems API RP 2003 defines the requirements for system grounding and bonding that can also generate a system shutdown. This may cause multiple tickets to be created for a single transaction. This precaution against ignition will minimize the accumulation of static electricity on the tank truck and rail shell but cannot ensure the dissipation of all static electricity within the system. Grounding the tank truck and rail does not prevent the accumulation of static electricity in a liquid with poor conductive properties. 11 Overfill Protection Systems API RP 1004 defines the requirements for automatic tank overfill protection that can also generate a system shutdown. This may cause multiple tickets to be created for a single transaction. 12 Calculations of Quality and Quantity Refer to MPMS Chapter 6.1 for volume and/or mass calculations. Weights and measures authorities typically require that the weighted average product temperature be printed on invoices for customers that are billed at net standard volume. For this reason, a temperature correction system should be used. In addition, automatic temperature correction can greatly aid facilities in the reconciliation of product inventories. See API MPMS Chapter 12 for information on calculations. 13 Preset 13.1 General Presets are electronic and/or mechanical devices used in conjunction with metering devices and instrumentation to calculate incoming data into volumes or mass at base conditions. Presets may also be called lane controllers, batch controllers, or unit control devices Electronic presets Most electronic preset instruments are capable of correcting to gross standard volume (GSV) that includes indicated volume, meter factor, temperature and pressure compensation. When using the preset to calculate for temperature correction incorporating CTL (correction for the temperature of a liquid), the temperature measuring element is connected directly to the preset, and the preset calculates the volume based on a measured temperature. When using the preset to calculate for pressure compensation incorporating CPL (correction for the pressure of a liquid), the pressure measuring element is connected directly to the preset, and the preset calculates the volume based on a measured pressure. When utilizing these types of volume correction, it is imperative that the preset applies the proper volume correction factor for the given product based on the appropriate tables from API MPMS Ch It is also imperative that the proper product gravity is applied when calculating the volume correction factor Mechanical presets a) A mechanical preset is a non-repeating, predetermining counter that is driven by and normally mounted on a flow meter; generally for use on positive displacement (PD) meters. A two stage output interface on

21 the preset is used to control a valve in two stages (low flow and high flow rates). The mechanical registration is adjusted by calibration in the flow meter. b) Mechanical presets are available with various accessories that usually include a mechanical ticket printer that is mounted directly on the preset that will indicate the amount of liquid volume that was delivered for a preset operation. c) Some systems use automatic temperature compensation devices (e.g., ATC/ATG). The ATC is a mechanical meter mounted temperature compensator that requires a fixed gravity selection. The ATG is a mechanical meter mounted temperature compensator that offers the operator an adjustable gravity selector system. Meters equipped with either the ATC or ATG provide for a temperature corrected volume registration on the mechanical preset. 14 Operations Load and unloading operations can be controlled using an electronic preset. This device is a batch controller specifically designed for automated loading and unloading operations. It can operate in either a standalone or automated mode when interfaced with a Terminal Automation System (TAS). It provides the required measurement data during loading for the bill of lading (BOL) printout by the TAS, or by a printer in standalone mode. The electronic preset can support the various blending operations as described in Section 13 or straight product loading and includes a staged flow profile used for product transfer. Additional typical preset functions include: a) Individual product measurement profiles to apply the unique measurement characteristics to each product it is controlling. Configurable parameters such as meter factor, volume correction factors, temperature and pressure compensation factors with selectable units of measurement including volumetric measurement and mass measurement. Configurable individual product flow profiles to maintain accurate flow control rate parameters within the specified meter(s) range of operation for accurate measurement at all times. Some of these include: minimum and maximum flow rates, flow tolerance, first and final trip volumes. b) Configurable discrete inputs and outputs to associated flow control and measurement devices, permissives for safety such as vehicle grounding and compartment overfill protection and various other load rack device interfaces should be included. c) Support for multiple additive injection control and monitoring for products where additives or dyes could also be required. d) Communications ports, Serial and/or Ethernet ports, that support Terminal Automation Systems (TAS), Additive Injection Systems, Card Readers and other various communicable interface devices may be included e) Printout or archival of all measured product data. f) Configurable levels of alarms and messaging for monitoring the loading and unloading operation. g) Interface with meter proving operations. h) In the event of a power loss during loading operations, the preset should be capable to retain and archive all measured data stored and in process if loading is in operation for retrieval when power is restored 15 Terminal Automation System 15.1 General When utilized, the Terminal Automation System (TAS) manages product distribution at the facility. Product is unloaded separately for each supplier, and product throughput is automatically reconciled over a configurable period, normally set to every 24 hours. Reports are automatically generated for each supplier and access to

22 information is fully password-protected. Automatic tank gauge systems can be connected to the TAS to provide a comparison between physical tank inventories versus calculated inventory based on throughput. Any differences are reported as gain/loss amounts for that period. The TAS should include the ability to account for bulk movements of product within the facility and product receipts or transfers to and from the facility. The TAS can support both order-driven operations with preset amounts automatically downloaded to the electronic preset, and allocation-based operations where drivers enter a customer number and the desired preset amount of product on the electronic preset. This amount is checked against the customer s product allocation before the load is authorized. The TAS should be capable of supporting unmanned operations at all times. Messages displayed at the loading and unloading should be simple and easy to understand to help reduce loading times. (Relocated Need to Review) The TAS should include the ability to provide net volume calculations. Refer to API MPMS Ch Card Systems The terminal automation system may include the option to provide controlled access to and from the terminal using a card reader device installed at convenient locations where controlled access or activity is logged within the terminal. The card reader device may include a display to view message prompts and a keypad to enter data based on the messages displayed. The card reader devices are connected to the TAS to provide real-time communications for data entry validation. The operator or driver is responsible for placing the card in the card reader for a successful read to validate the card data, and for entering any unique PIN or additional information required. Cards can be used as a single device with additional prompts for supplier, customer, and vehicle information, or multiple cards can be used to provide this information. Data provided from the cards is used for security and also can be printed on the bill of lading Security The TAS can include multiple levels of password protection with log of user access by date and time and user ID. Any changes to the TAS configuration should be clearly traceable using an event log file and print out. An audit trial file and print out is also included to show all transactions of product movement at the terminal Bill of Lading Printers Bill of lading printers are connected to the TAS and print the bill of lading upon completion of load. Multiple bill of lading printers may be required to support printout of bill of lading at preferred locations or per supplier. No vehicle can leave the terminal without a bill of lading. The option should be available to withhold the bill of lading if loading information is not correct; this is especially important for additive amounts included with the main product. Requirements for information on the bill of lading vary by state and company. Data can include Department of Transportation information relating to the particular products. 16 LPG LPG loading and unloading metering systems require the same selection, installation and meter proving requirements of loading and unloading metering systems for other petroleum products. Notable exceptions would be the use of air eliminators and excess flow valves. Air eliminators are not used in LPG systems. The system pressure is maintained to ensure the product remains in a liquid phase. Excess flow valves are safety devices used to stop flow in the event of a broken hose connection. If truck and rail car loading or offloading for high vapor pressure products (i.e. LPGs) are equipped with vapor equalization lines connected to the supply or receiving vessel(s) the volume should be measured 16.1 Back Pressure The back pressure shall be adequate to keep the fluid in the liquid phase. For measurement purposes the pressure at measurement temperature should be twice the pressure drop across the meter at maximum operating flow rate,

Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX

Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX 77002-5227 Overview In this paper I will attempt to give a fundamental overview of

More information

API MPMS Chapter 18.2 Custody Transfer of Crude Oil from Lease Tanks Using Alternative Measurement Methods 1 ST EDITION, DATE

API MPMS Chapter 18.2 Custody Transfer of Crude Oil from Lease Tanks Using Alternative Measurement Methods 1 ST EDITION, DATE API MPMS Chapter 18.2 Custody Transfer of Crude Oil from Lease Tanks Using Alternative Measurement Methods 1 ST EDITION, DATE Foreword Nothing contained in any API publication is to be construed as granting

More information

LACT Unit. Smith Meter LACT Unit. Technical Paper. Introduction. *Coriolis Meter

LACT Unit. Smith Meter LACT Unit. Technical Paper. Introduction. *Coriolis Meter Smith Meter LACT Unit LACT Unit Technical Paper Issue/Rev. 0.1 (2/12) Bulletin TP0A016 L Start Strainer/Air Release Controls BS & W Monitor Storage Tank L Stop BS&W Probe Sample Probe *Coriolis Meter To

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS ITEM 00520 WEIGHING AND MEASURING EQUIPMENT 520.1 Description. This item shall govern for the weighing and measuring equipment utilized where materials are specified to be measured

More information

Custody Transfer: Technical principles for measuring system in the O&G market

Custody Transfer: Technical principles for measuring system in the O&G market GdS - Misure Fiscali Milan, October, 25 2018 Auditorium TECNIMONT Custody Transfer: Technical principles for measuring system in the O&G market Fabio Fusi Sales Specialist Market Overview Define Custody

More information

API Review. Copyright 2007, FMC Technologies Measurement Solutions, Inc. PR0A028I Issue/Rev. 0.0 (7/07) - Slide 1

API Review. Copyright 2007, FMC Technologies Measurement Solutions, Inc. PR0A028I Issue/Rev. 0.0 (7/07) - Slide 1 API Review PR0A028I Issue/Rev. 0.0 (7/07) - Slide 1 API MPMS Chapter 5, Section 1 General Considerations for Measurement by Meters PR0A028I Issue/Rev. 0.0 (7/07) - Slide 2 Introduction 5.1.1 The advantages

More information

Table of Contents. Section Mass Flow Meters

Table of Contents. Section Mass Flow Meters Handbook 44 2014 3.37. Mass Flow Meters Table of Contents Section 3.37. Mass Flow Meters... 3-103 A. Application... 3-103 A.1. Liquids.... 3-103 A.2. Vapor (Gases).... 3-103 A.3. Additional Code Requirements...

More information

OPERATIONAL EXPERIENCE WITH SMALL VOLUME PROVERS. Class #4110.1

OPERATIONAL EXPERIENCE WITH SMALL VOLUME PROVERS. Class #4110.1 OPERATIONAL EXPERIENCE WITH SMALL VOLUME PROVERS Class #4110.1 Steve Whitman Coastal Flow Liquid Measurement, Inc. 2222 Bay Area Blvd., Suite 200 Houston, Texas 77058 Introduction Introduced decades ago,

More information

Custom Fluid and Gas Handling THE SINGLE SOURCE FOR ALL OF YOUR FLUID HANDLING NEEDS

Custom Fluid and Gas Handling THE SINGLE SOURCE FOR ALL OF YOUR FLUID HANDLING NEEDS Custom Fluid and Gas Handling S O L U T I O N S THE SINGLE SOURCE FOR ALL OF YOUR FLUID HANDLING NEEDS Contents Engineering & Design 2 Automation Controls 3 Truck Railcar Loading - Unloading 4 Metering

More information

What ensures measurement to accurate standards?

What ensures measurement to accurate standards? What ensures measurement to accurate standards? The SITRANS FUT1010 calibrated ultrasonic flow meter tells you exactly what s flowing Answers for Industry. SITRANS FUT1010 Custody transfer accuracy with

More information

TANKER LOADING SKIDS FOR OIL DISTRIBUTION DEPOTS

TANKER LOADING SKIDS FOR OIL DISTRIBUTION DEPOTS TANKER LOADING SKIDS FOR OIL DISTRIBUTION DEPOTS The IFC Inflow bottom loading skid is designed for the safe, fast & efficient loading of road tankers in oil distribution depots & bulk fuel tanker loading

More information

Smith Meter AccuLoad III Unloading

Smith Meter AccuLoad III Unloading Electronic Preset Delivery System Smith Meter AccuLoad III Unloading Issue/Rev. 0.1 (10/10) Bulletin AB06055 Overview Note: This feature is only available when using AccuLoad III-X Revision 10.01 firmware

More information

LIQUID CONTROLS. Terminal and Bulk Plant Metering Applications. Application Brochure:

LIQUID CONTROLS. Terminal and Bulk Plant Metering Applications.  Application Brochure: LIQUID CONTROLS Terminal and Bulk Plant Metering Applications Application Brochure: 200-40 www.lcmeter.com Premier products, premier performance Liquid Controls Group offers a broad selection of positive

More information

GUIDELINES FOR STOCK CONTROL AT JOINT VENTURE AIRPORT OPERATIONS

GUIDELINES FOR STOCK CONTROL AT JOINT VENTURE AIRPORT OPERATIONS JIG CP 5.02 Document Application: Common Process GUIDELINES FOR STOCK CONTROL AT JOINT VENTURE AIRPORT OPERATIONS CP 5.02 Issue Date: 1 st July 2012 Issue Number: 0 Date Issued: 1st July 2012 Revision

More information

DTN Guardian3. Make the most of your energy SM

DTN Guardian3. Make the most of your energy SM DTN Guardian3 With DTN Guardian3 for ethanol terminal automation, you can optimize inventory and demand, manage volumetric and weighed products, and ensure safety and security. Make the most of your energy

More information

Section Belt-Conveyor Scale Systems

Section Belt-Conveyor Scale Systems Handbook 44-2007 2.21. Belt-Conveyor Scale Systems Section 2.21. Belt-Conveyor Scale Systems A. Application A.1. This code applies to belt-conveyor scale systems used for the weighing of bulk materials.

More information

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety IEA/SHC Task 57, Subtask B Draft proposals for new test procedures B4: Final Draft Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety HE Zinian Beijing

More information

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Technical Guidance Note (Monitoring) M5 Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Environment Agency XXXX 2018 Version X Draft for consultation Foreword

More information

4. OPERATING CONTROLS

4. OPERATING CONTROLS 4. OPERATING CONTROLS 4.1 Custody Transfer Custody Transfer, the transfer of product from or to a Shipper, normally occurs at point of measurement, e.g. through meters, or in the following manner: Receipts

More information

CRYOGENIC FLUIDS CHAPTER 55

CRYOGENIC FLUIDS CHAPTER 55 CHAPTER 55 CRYOGENIC FLUIDS SECTION 5501 GENERAL 5501.1 Scope. Storage, use and handling of cryogenic fluids shall comply with this chapter. Cryogenic fluids classified as hazardous materials shall also

More information

Transient and Succession-of-Steady-States Pipeline Flow Models

Transient and Succession-of-Steady-States Pipeline Flow Models Transient and Succession-of-Steady-States Pipeline Flow Models Jerry L. Modisette, PhD, Consultant Jason P. Modisette, PhD, Energy Solutions International This paper is copyrighted to the Pipeline Simulation

More information

Checklist for testing electronic digital indicators with simulated pulses 2/6/08

Checklist for testing electronic digital indicators with simulated pulses 2/6/08 Appendix E Checklist for Testing Electronic Digital Indicators with Simulated Pulses This checklist is used for Technical Policy U. Evaluating electronic digital indicators submitted separate from a measuring

More information

SECTION CHEMICAL FEED SYSTEM

SECTION CHEMICAL FEED SYSTEM SECTION 11800 PART 1 GENERAL 1.1 SUMMARY A. This section includes the requirements for the chemical feed system shall be a complete turnkey system inclusive of all necessary fluid handling and ancillary

More information

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products

Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial. Richard Gruskos Flow Products Manager Kessler Ellis Products Utility Flow Metering for Steam and Heated/Chilled Water: A Tutorial Richard Gruskos Flow Products Manager Kessler Ellis Products Review Flow Metering Principles: Flow Meters and Flow Computers Utility

More information

Yes No N/A. Yes No N/A. Yes No N/A. Yes No N/A

Yes No N/A. Yes No N/A. Yes No N/A. Yes No N/A Page 1 of 11 This checklist is used for Technical Policy U. Evaluating electronic digital indicators submitted separate from a measuring element. This section is intended for lab testing only. Is permanence

More information

The following definitions apply with regard to requirements specified in this document:

The following definitions apply with regard to requirements specified in this document: GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved

More information

EI/JIG STANDARD 1530 Guidance for locations which currently operate to JIG 3 Standards

EI/JIG STANDARD 1530 Guidance for locations which currently operate to JIG 3 Standards EI/JIG STANDARD 1530 Guidance for locations which currently operate to JIG 3 Standards Background JIG Bulletin 68 provided initial guidance to airport and distribution facility users of JIG Standards regarding

More information

Field Inspection Manual Part: 2-ASTP Section: 3 - DTWS Page: 1 of 18. Automatic Weighing Devices Issued: Revision Number: Original

Field Inspection Manual Part: 2-ASTP Section: 3 - DTWS Page: 1 of 18. Automatic Weighing Devices Issued: Revision Number: Original Field Inspection Manual Part: 2-ASTP Section: 3 - DTWS Page: 1 of 18 REFERENCE Weights and Mesures Regulations, NAWDS & the National Technical Training Bulk Weigher Training Module. PURPOSE The following

More information

Tank Truck Bottom Loading and Overflow Protection Systems

Tank Truck Bottom Loading and Overflow Protection Systems Fuels Safety Program Standard PTT 101 Ref. No.: Rev. No.: PTT 101 4 Date: Date: 1977 November 2017 Tank Truck Bottom Loading and Overflow Protection Systems Page 1 Foreword This document presents the Standard

More information

Fiscal and Allocation Metering

Fiscal and Allocation Metering Fiscal and Allocation Metering Course Price 2950 Course Description The smallest error in the flow measurement of materials like oil, gas, or chemicals being transferred between a producer (supplier) and

More information

Crude oil and condensate sampling. Jiskoot Ltd

Crude oil and condensate sampling. Jiskoot Ltd Crude oil and condensate sampling Jiskoot Ltd Jiskoot UK and USA based International network of over 50 agents Our equipment handles over 60% of world crude oil Local support Sphere of operations Sampling

More information

Mitigating Lost & Unaccounted-For Gas

Mitigating Lost & Unaccounted-For Gas Mitigating Lost & Unaccounted-For Gas Determination and Corrective Action in Contemporary Upstream, Midstream and Downstream Operations Author: Duane Harris Vice President, Business Development Flow-Cal,

More information

CRYOGENIC FLUIDS CHAPTER 32

CRYOGENIC FLUIDS CHAPTER 32 CHAPTER 32 CRYOGENIC FLUIDS SECTION 3201 GENERAL 3201.1 Scope. Storage, use and handling of cryogenic fluids shall comply with this chapter. Cryogenic fluids classified as hazardous materials shall also

More information

CRYOGENIC FLUIDS CHAPTER 32

CRYOGENIC FLUIDS CHAPTER 32 CHAPTER 32 CRYOGENIC FLUIDS SECTION 3201 GENERAL 3201.1 Scope. Storage, use and handling of cryogenic fluids shall comply with this chapter. Cryogenic fluids classified as hazardous materials shall also

More information

Industrial Control Systems. Terminal Automation System

Industrial Control Systems. Terminal Automation System Industrial Control Systems Terminal Automation System Flashtech Terminal Automation System Flashtech Terminal Automation System 2 Flashtech is a Terminal Automation Package that controls the flow of

More information

Tank Scale Service Checklist

Tank Scale Service Checklist Tank Scale Service Checklist Specifying Service for Optimized Weighing Processes Selecting the right weighing equipment is an important first step to ensuring that your weighing processes are able to meet

More information

C.A.S.E. Air Carrier Section Policies and Procedures

C.A.S.E. Air Carrier Section Policies and Procedures FUEL STORAGE CHECKLIST Audit Date: Station Code: City: Vendor Name: Address: Primary Contact: Title: Phone: Fax: Auditor: Acceptable: Conditionally Acceptable Not Acceptable Register: (Circle One) Add

More information

SECTION Coriolis Mass Flow Meters

SECTION Coriolis Mass Flow Meters SECTION 40 71 73 Coriolis Mass Flow Meters PART 1- GENERAL 1.01 SUMMARY A. Coriolis flow meter for permanent installation above ground. The meter shall utilize a measuring principle based on the controlled

More information

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management... COIN Flow Meters Segmented Wedge Your First Choice in Intelligent Flow Management COIN Flowmeter The Preso COIN Flowmeter accommodates most flows, even the most abrasive Accuracy and reliability are achieved

More information

2015 NIST EPO No. 16

2015 NIST EPO No. 16 Examination Procedure Outline for Automatic Bulk Weighing Systems It is recommended that this outline be followed for automatic bulk weighing systems (ABWS s); that is, weighing systems adapted to the

More information

EXHIBIT B. Notice of Non-Compliance

EXHIBIT B. Notice of Non-Compliance Page 1 of 6 EXHIBIT B Town of Flower Mound Large Residential and Commercial Water Meter Installation Policy 3-6 Compound or HP Turbine Meters Or 2 Compound Meter (06/20/05) The Town of Flower Mound has

More information

LEASE AUTOMATIC CUSTODY TRANSFER UNITS (LACT UNITS)

LEASE AUTOMATIC CUSTODY TRANSFER UNITS (LACT UNITS) LEASE AUTOMATIC CUSTODY TRANSFER UNITS (LACT UNITS) The Custody Transfer concept applies when the possession of crude oil or petroleum product is transferred from one legal entity to another. LACT units

More information

CHAPTER 6 : GAS SAMPLING SYSTEMS

CHAPTER 6 : GAS SAMPLING SYSTEMS CHAPTER 6 : GAS SAMPLING SYSTEMS 1 Scope : 1.1 This Chapter describes two types of gas sampling systems in paragraphs 2.1 and 2.2 meeting the requirements specified in para 4.2 of Chapter 3 of this Part.

More information

Product range. Product range

Product range. Product range Product range Product range Overview For all Types of Energy The increase of energy efficiency gains an important value since the rise of the commodity prices. Not only does this involve the electric current

More information

Crude Quality and Quantity Issues Kesavalu M. Bagawandoss, Ph.D., J.D., & Louis Ory.

Crude Quality and Quantity Issues Kesavalu M. Bagawandoss, Ph.D., J.D., & Louis Ory. Crude Quality and Quantity Issues Kesavalu M. Bagawandoss, Ph.D., J.D., & Louis Ory Outline of Presentation Introduction Issues of Quality and Quantity Safety Sampling An Extensive Global Network Founded

More information

December 14, 2015 VIA ELECTRONIC FILING

December 14, 2015 VIA ELECTRONIC FILING December 14, 2015 VIA ELECTRONIC FILING Director Neil Kornze U.S. Department of the Interior Bureau of Land Management Mail Stop 2134 LM 1849 C Street, NW Washington, D.C. 20240 Re: Docket No. BLM-2015-0004

More information

GASSO Skid Mounted Measuring Systems for Loading Terminals TECHNICAL SPECIFICATION

GASSO Skid Mounted Measuring Systems for Loading Terminals TECHNICAL SPECIFICATION GASSO Skid Mounted Measuring Systems for Loading Terminals TECHNICAL SPECIFICATION 1. Introduction The safest and most accurate method of transferring petroleum products from bulk storage to a transport

More information

GUIDELINES FOR INSTALLATION OF ABOVEGROUND DIESEL FUEL TANKS

GUIDELINES FOR INSTALLATION OF ABOVEGROUND DIESEL FUEL TANKS GUIDELINES FOR INSTALLATION OF ABOVEGROUND DIESEL FUEL TANKS Revised 1/1/17 Authority cited: California Fire Code; National Fire Protection Association 30 (NFPA) Flammable and Combustible Liquids Code

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 16431 First edition 2012-01-15 Corrected version 2012-03-15 Hydraulic fluid power System cleanup procedures and verification of cleanliness of assembled systems Transmissions

More information

Manual of Petroleum Measurement Standards Chapter 5 Metering

Manual of Petroleum Measurement Standards Chapter 5 Metering Addendum 1 July 2009 Manual of Petroleum Measurement Standards Chapter 5 Metering Section 3 Measurement of Liquid Hydrocarbons by Turbine Meters FIFTH EDITION, SEPTEMBER 2005 Addendum to MPMS Chapter

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10438-3 Second edition 2007-12-15 Petroleum, petrochemical and natural gas industries Lubrication, shaft-sealing and control-oil systems and auxiliaries Part 3: General-purpose

More information

e-cfr Data is current as of October 16, 2017

e-cfr Data is current as of October 16, 2017 e-cfr Data is current as of October 16, 2017 Title 40: Protection of Environment PART 63 NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES Subpart BBBBBB National Emission

More information

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below) CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE APPENDIX C - ALTERNATE PLUMBING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority

More information

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM SECTION 40 71 73 CORIOLIS MASS FLOW MEASURING SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Coriolis flow meter for permanent installation above ground. The meter shall utilize a measuring principle based on

More information

Manual of Petroleum Measurement Standards Chapter 21 Electronic Flow Measurement (EFM)

Manual of Petroleum Measurement Standards Chapter 21 Electronic Flow Measurement (EFM) Manual of Petroleum Measurement Standards Chapter 21 Electronic Flow Measurement (EFM) Mark Godfrey Engineering Services Manager OMNI Flow Computers inc 1 Introduction MPMS Chapter 21 1. Chapter 21.1 Electronic

More information

Storage Tanks and Other Field Facilities

Storage Tanks and Other Field Facilities 8 Storage Tanks and Other Field Facilities This chapter is devoted to the discussion of storage tanks of crude oil and other hydrocarbons, vapor recovery units (VRUs), and piping in the oil field, including

More information

U. S. Army Corps of Engineers Liquid Phase Carbon Adsorption Checklist

U. S. Army Corps of Engineers Liquid Phase Carbon Adsorption Checklist U. S. Army Corps of Engineers Liquid Phase Carbon Adsorption Checklist Installation Name Site Name / I.D. Evaluation Team Site Visit Date This checklist is designed to facilitate the performance evaluation

More information

The rules and regulations, as part of this document, shall apply to all premises serviced by the public water system of the Northeast Water System.

The rules and regulations, as part of this document, shall apply to all premises serviced by the public water system of the Northeast Water System. RULES AND REGULATIONS TO PROVIDE AN EFFECTIVE MEANS FOR PROTECTING THE PUBLIC WATER SYSTEM FROM CONTAMINATION DUE TO BACKFLOW OF CONTAMINATES THROUGH THE WATER SERVICE CONNECTION INTO THE PUBLIC WATER

More information

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS approvals required to become an API Standard. It shall not be produced or circulated or quoted, in whole or in part, API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Chapter 7.5 Temperature Determination

More information

Rockwood Water People s Utility District Cross Connection Implementation and Regulations

Rockwood Water People s Utility District Cross Connection Implementation and Regulations Rockwood Water People s Utility District Cross Connection Implementation and Regulations To ensure clean, safe, potable water, Rockwood Water People s Utility District (PUD) maintains a cross connection

More information

Transport bulk gases by road

Transport bulk gases by road Page 1 of 9 Transport bulk gases by road Level 4 Credits 15 Purpose This unit standard is for drivers of road tank wagons who load, transport and unload bulk gases under pressure, including hazardous and

More information

Fuel Management in Tank Farms and Terminals

Fuel Management in Tank Farms and Terminals [MFX_4] Systems Technology Fuel Management in Tank Farms and Terminals 001739 0001 044 [02] [Fuel Management in tank farms and terminals] Loading Technology guarantees seamless operation in small as well

More information

Comments on All Items in Block 4 Regarding Transfer Standards. 1. Comments Applicable to All Items Regarding Transfer Standards

Comments on All Items in Block 4 Regarding Transfer Standards. 1. Comments Applicable to All Items Regarding Transfer Standards Comments on All Items in Block 4 Regarding Transfer Standards Submitted by Seraphin Test Measure Company A Division of Pemberton Fabricators, Inc. 1 June 29, 2018 Representatives of the NIST Office of

More information

SAFEWORK PRACTICES TRUCK LOADING CAT A-2, SOP #25

SAFEWORK PRACTICES TRUCK LOADING CAT A-2, SOP #25 SUNCOR ENERGY PRODUCTS DISTRIBUTION TERMINAL OPERATING MANUAL STANDARD OPERATING PROCEDURE SAFEWORK PRACTICES CAT A-2, SOP #25 Date Issued: June 2010 Revision Date: July 2012 Review Date: July 2015 Revision

More information

Optimizing Performance Bench Scale Service Checklist

Optimizing Performance Bench Scale Service Checklist Optimizing Performance Bench Scale Specifying Service For optimized weighing processes Selecting the right weighing equipment is an important first step to ensuring that your weighing processes are able

More information

(4) Production inspection is the inspection that must initially be conducted on each newly manufactured IBC.

(4) Production inspection is the inspection that must initially be conducted on each newly manufactured IBC. Subpart O Testing of IBCs 178.800 Purpose and scope. This subpart prescribes certain testing requirements for IBCs identified in subpart N of this part. [Amdt. 178 103, 59 FR 38074, July 26, 1994, as amended

More information

EL DORADO IRRIGATION DISTRICT

EL DORADO IRRIGATION DISTRICT EL DORADO IRRIGATION DISTRICT Per Administrative Regulation 5021 Cross-Connection Control and Prevention of Backflow Program Prepared by Environmental Division of the Engineering Department Revised November

More information

Fluid Flow Conditioning. August 2015

Fluid Flow Conditioning. August 2015 Fluid Flow Conditioning August 2015 Flow Conditioning There is no flow meter on the market that needs flow conditioning. All flow meters are effective without any type of flow conditioning. Flow Conditioning

More information

Advanced Solutions. Honeywell Profit Movement Suite. Solution Note

Advanced Solutions. Honeywell Profit Movement Suite. Solution Note Advanced Solutions Solution Note Solution Note Honeywell Profit Movement Suite Honeywell s Profit Movement Suite is effective, field-proven software for monitoring and controlling material movement operations

More information

Choosing The Correct Flow Meters For Hydraulic Fracturing

Choosing The Correct Flow Meters For Hydraulic Fracturing WHITE PAPER Choosing The Correct Flow Meters For Hydraulic Fracturing INTRODUCTION Hydraulic Fracturing requires accurate and durable flow meters to monitor several processes during a fracking treatment.

More information

OMT Asphalt Plant Inspection Checklist

OMT Asphalt Plant Inspection Checklist OMT Asphalt Plant Inspection Checklist The Asphalt Producer will complete all fields. Those marked with a will be verified by the QA Field Team. Plant Description Name & Type of Plant Location ATD Field

More information

Assessment Schedule - TS.5

Assessment Schedule - TS.5 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

Guideline for In-Service Assessment of Ammonia Refrigeration Plants

Guideline for In-Service Assessment of Ammonia Refrigeration Plants Guideline for In-Service Assessment of Ammonia Refrigeration Plants This communication is intended to be used by plant owners and operators to provide guidance in preparation for an assessment of the plant

More information

B. ASHRAE 1991 HVAC Applications Handbook: Chapter 34--Testing, Adjusting and Balancing.

B. ASHRAE 1991 HVAC Applications Handbook: Chapter 34--Testing, Adjusting and Balancing. PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 230593 TESTING, ADJUSTING, AND BALANCING A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Wastewater Capital Projects Management Standard Construction Specification

Wastewater Capital Projects Management Standard Construction Specification CITY AND COUNTY OF DENVER ENGINEERING DIVISION Wastewater Capital Projects Management Standard Construction Specification 7.4 PERMEATION GROUTING 7.4.1 Definitions 7.4.1.1 Geotechnical Data Report (GDR)

More information

QUALITY ASSURANCE PROTOCOL (QAP)

QUALITY ASSURANCE PROTOCOL (QAP) PREFACE This Standard details the level of documentation that PVT.LTD (IET) will provide during a contract for fabricating tank(s) or portable equipment s. Extensive documentation is required for this

More information

WYATT Orifice flow PrOducTs

WYATT Orifice flow PrOducTs WYATT Orifice Differential producers, specifically orifice plates, are used in flow measurement due to their simplicity, ease of installation, tolerance to extreme atmospheric and process conditions, and

More information

Maintenance Program Guideline for Owners of Ammonia Plants

Maintenance Program Guideline for Owners of Ammonia Plants Maintenance Program Guideline for Owners of Ammonia Plants Contents Maintenance Program Guideline for Owners of Ammonia Plants... 0 a) Title Page, owner/operator, the plant location.... 4 b) Contents Page...

More information

Tank Farm Operations and Performance Nov May Nov 2017 Dubai, United Arab Emirates

Tank Farm Operations and Performance Nov May Nov 2017 Dubai, United Arab Emirates 20-24 Nov 2016 21-25 May 2017 19-23 Nov 2017 Dubai, United Arab Emirates Topics discussed include: 09-AUG-16 This course is Designed, Developed, and will be Delivered under ISO 29990:2010 & ISO 9001:2015

More information

Handling Fluid Fertilizers Selecting the Right Equipment Components

Handling Fluid Fertilizers Selecting the Right Equipment Components Handling Fluid Fertilizers Selecting the Right Equipment Components 9/2/2010 1 Considerations Systematic approach Compatible components Short term vs. long term Plan ahead for future expansion 9/2/2010

More information

MIDSTREAM AND INDUSTRIAL EQUIPMENT

MIDSTREAM AND INDUSTRIAL EQUIPMENT Superior Energy Systems MIDSTREAM AND INDUSTRIAL EQUIPMENT Superior Design. Superior Quality. Superior Service. Why would you settle for anything less? For more than 40 years we ve brought together engineering,

More information

Custom Systems Built to Exacting Client Specification

Custom Systems Built to Exacting Client Specification Custom Systems Built to Exacting Client Specification Laboratory Reactor Systems Parr Instrument Company is pleased to work with customers in the design and assembly of complete laboratory or pilot plant

More information

Fire-Protection Considerations for the Design and Operation of Liquefied Petroleum Gas (LPG) Storage Facilities

Fire-Protection Considerations for the Design and Operation of Liquefied Petroleum Gas (LPG) Storage Facilities Fire-Protection Considerations for the Design and Operation of Liquefied Petroleum Gas (LPG) Storage Facilities API PUBLICATION 2510A SECOND EDITION, DECEMBER 1996 REAFFIRMED, DECEMBER 2015 Fire-Protection

More information

Automation Valves Measurement Process Control. TruckVue Transfer System

Automation Valves Measurement Process Control. TruckVue Transfer System Automation Valves Measurement Process Control TruckVue Transfer System Preventative Maintenance Agreement (PMA) Prevent and reduce transfer system disruptions/outages over the entire life cycle Built for

More information

METROLOGICAL INFRASTRUCTURE FOR OIL FLOW METERS CALIBRATION AND TESTING

METROLOGICAL INFRASTRUCTURE FOR OIL FLOW METERS CALIBRATION AND TESTING METROLOGICAL INFRASTRUCTURE FOR OIL FLOW METERS CALIBRATION AND TESTING Kazuto Kawakita 1, Guilherme Silveira dos Santos 2, André Ferreira 3 1 IPT-Instituto de Pesquisas Tecnológicas, São Paulo/SP, Brasil,

More information

LNG workshop. Flow Metering. Peter Lucas and Nikola Pelevic

LNG workshop. Flow Metering. Peter Lucas and Nikola Pelevic LNG workshop Flow Metering Peter Lucas and Nikola Pelevic Physical Properties Page Flow metering Contents of this module Flow meter technology Fluid properties and measurement Calibration methods Field

More information

Transmission Pipeline Opportunities. Advancing Project Development in India through Public Private Partnerships

Transmission Pipeline Opportunities. Advancing Project Development in India through Public Private Partnerships Transmission Pipeline Opportunities Advancing Project Development in India through Public Private Partnerships 22 23 February, 2007 Pipeline Maintenance and Repair: Agenda Methane Losses from Pipeline

More information

SANITARY SEWER CHEMICAL GROUTING

SANITARY SEWER CHEMICAL GROUTING Specification The information contained in the document is property of Avanti International. Avanti offers the following verbiage as a technical reference to assist in the creation of specifications for

More information

OIL RECORD BOOK INSTRUCTIONS

OIL RECORD BOOK INSTRUCTIONS OIL RECORD BOOK INSTRUCTIONS Oil Record Book, Part I - Machinery space operations (All Ships) The following pages of this section show a comprehensive list of items of machinery space operations which

More information

Chemigation. in Georgia

Chemigation. in Georgia Chemigation in Georgia Table of Contents Chemigation Terminology...3 The Benefits of Chemigation...3 General Principles of Chemigation Safety Considerations...3 Injection Methods...4 Determining Injection

More information

PROCESS OPERATIONS. Introduction to Operations. Diagrams for the Operating Unit. Revised 11/30/18 1

PROCESS OPERATIONS. Introduction to Operations. Diagrams for the Operating Unit. Revised 11/30/18 1 TOPIC Introduction to Operations Diagrams for the Operating Unit OBJECTIVES 1. Discuss the importance of this course as a capstone experience in the Process Technology program and how the material learned

More information

Gilflo flowmeters. for steam, liquids and gases

Gilflo flowmeters. for steam, liquids and gases Gilflo flowmeters for steam, liquids and gases The Gilflo spring loaded variable area flowmeter... offers an unrivalled 1:1 turndown and can be used to meter most industrial fluids including steam and

More information

Solutions for Terminals

Solutions for Terminals Products Solutions Services Solutions for Terminals Andrea Calo Slide 1 Terminal Activities Storage Terminal Automation ERP (Business Integration) Tank / Silo Monitoring Blending & Additive System Safety

More information

Reduction of Apparent Losses Using the UFR (Unmeasured-Flow Reducer) Case Studies

Reduction of Apparent Losses Using the UFR (Unmeasured-Flow Reducer) Case Studies Reduction of Apparent Losses Using the UFR (Unmeasured-Flow Reducer) Case Studies Sharon Yaniv* *A.R.I Flow Control Accessories, Kfar Charuv, 12932, Israel, Sharon@ari.co.il Abstract The demand for water

More information

DustCheck DPM-16. Previous Go to PM10-2,5 sampling adding the Wins impactor 9 of 75 Next Go to DustCheck DPM-5. Sequential sampler

DustCheck DPM-16. Previous Go to PM10-2,5 sampling adding the Wins impactor 9 of 75 Next Go to DustCheck DPM-5. Sequential sampler Previous Go to PM10-2,5 sampling adding the Wins impactor 9 of 75 Next Go to DustCheck DPM-5 DustCheck DPM-16 Sequential sampler NEW! DustCheck DPM-16 is the new sequential sampler complying with EN-12341:2014

More information

CAD CONTROL SYSTEMS Exclusive Sales & Service Agent

CAD CONTROL SYSTEMS Exclusive Sales & Service Agent Established in 1983, CAD Control Systems has long been recognized as a leader in the design and manufacture of BOP Control Systems, Diverter Control Systems, High Pressure Testing Systems and Subsea equipment

More information

Product Application Guidelines. Platform Scales

Product Application Guidelines. Platform Scales Product Application Guidelines Platform Scales Table of Contents Preface... 3 Introduction... 4 Platform scale selection... 4 Locating the scale... 5 Location... 5 Vibration... 5 Floor... 5 Bench... 5

More information

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA

METER SELECTION FOR VARIOUS LOAD REQUIREMENTS. Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX USA METER SELECTION FOR VARIOUS LOAD REQUIREMENTS Edgar B. Bowles, Jr. Southwest Research Institute 6220 Culebra Road San Antonio, TX 78238-5166 USA INTRODUCTION This paper is intended to provide meter station

More information