1 MANAGEMENT SERVICE 00 W 0 / TRD 00 LEVEL GAUGES YPBR - YUPR - YMPT - YUPT S T E 0 -

2 Level Gauges YPBR - YUPR - YUPT - YMPT Yakacık Level Gauges YAKACIK VALF Level Gauges have high mechanical endurance for various fluids such as steam and high temperature hot water. Fluid type, pressure and temperature are the main parameters used to choose the suitable level gauge. Application Areas Oil Refinery Plants Petrochemical Industry Pharmaceutical Plants Tank and Boilers Chemical Processes Textile Industry Shipyards Paper Industry

3 Yakacık Level Gauges Level Gauges for Steam and High Temp. Hot Water Temperature and pressure affect the fluid properties. While steam chemically affects the glass, condensate mechanically affects it. The environmental and working conditions for steam generating plants and prcess industries such as oil refinery plants, are quite different. Those differences should be taken into consideration to choose the suitable Level Gauge. Proven Safety for Glass Breakage When compared to other pressure vessels, the steam boilers are more frequently started and stopped. So the glass and the gauge is very important for them. The gauge body and the glass must be mechanically strong and resistant to thermal stresses. Transparent glass is placed in between special gaskets. The housing of glass is metal. If glass is broken, it does not spill out in tiny parts. Reflex Gauges: Up to Bars For pressure levels which do not exceed bars, the Reflex Gauges are the most economical solutions for steam boilers. Transparent, Mica Protected Gauges: Up to 0 Bars Transparent Level Gauges can be used up to 0 bars. If the pressure exceeds bars and the temperature exceeds 0 C, the surface of the glass in contact with the fluid, should be protected by mica. Equipping Transparent Level Gauges with an illuminator, enables easy observing. Level Gauges for Process Industries The environmental and working conditions, temperature and pressure should be taken into consideration to choose the suitable Level Gauge used in Process Industries. Temperature Range -9 C + 00 C - Level Gauges which are used in the process industries, are mainly exposed to non-varying conditions: extremely high pressures at low temperatures or low pressures at high temperatures. Applications at Low Temperature At cryogenic conditions, the metallic materials should have enough strength. Properties of the glass do not change very much with low temperatures. Visibility Problem Due to Icing With ice forming on the glass, the visibility deteriorites. For such cases, YAKACIK VALF presents antifreeze blocks. These blocks enable visibility in low temperatures. Level Gauges equipped with such acccessories must be isolated depending on the temperature level. Supplementary Heating Systems If the environment temperature drops to levels at which the fluid solidifies, it becomes impossible to use the Level Gauge. For such circumstances, YAKACIK VALF supplies supplementary heating systems. The medium is thereby maintained in the liquid state and good visibility is ensured.

4 Yakacık Level Gauges YAKACIK VALF Level Gauges enable the observer to monitor the fluid levels from outside. - Reflex Gauges A sealed reflex glass is placed into the gauge body. The fluid level can be seen from one side only. Application for Steam: Saturated steam up to bars. Display is quite clear. Steam zone appears in bright silver color. Liquid zone is dark. Depending on the fluid type, Reflex Gauges are used up to 00 bars and 00 C. Yakacık Reflex Glass Operating Principle of Reflex Glass Operation principle of Reflex Level Gauges is based on refractive index differences of liquids and gases for example water and steam. Reflex glass is assembled into the steel body which covers the steam and the water. Water level can be observed through the split behind the glass. There are prismatic grooves in Yakacık reflex glass. They are in contact with fluid. External light waves are absorbed in the fluid zone and reflected back in vapor zone. As a result, the water zone is seen as black, the vapor zone is seen as bright silver-white. The fluid level can be monitored easily. YAKACIK VALF Reflex Glasses Yakacık Valf reflex glasses are made of borosilicate. They are heat treated and have big resistance to erosion. They are not affected by thermal shocks and static temperature differences. Sealing gasket is provided with level gauge glass. Water Zone Gauge Glass Vapor Zone Gauge Glass Light Wave Light Wave Gauge Body

5 Yakacık Level Gauges - Transparent Gauges Two transparent glasses are mounted in the gauge body. The fluid level can be seen from two sides: front and back. Application for Steam: Saturated steam up to 0 bars. Gauge glasses are protected by mica placed in between the liquid and the glass. Display : An illuminator is necessary. Light creates an elliptic line between the vapor and the water zones. In Other Fluids : Up to 00 bars and 0 C. For colorless fluids like water, illuminator is necessary. For colored fluids, illuminator may not be needed. Display : When an illuminator is used, the liquid level is seen as an ellipse line. For colored liquids, the level is the top of dark liquid column. Mica Yakacık Transparent Glass

6 Level Gauges Type: YPBR PN bars 00 C 0 - mm Level Gauge Type Distance Between Flanges M (mm) Body Length K(mm) Observation Length S (mm) YPBR IV YPBR V YPBR VI YPBR VII YPBR VIII YPBR IX YPBR xiv YPBR xv YPBR xvi YPBR xvii YPBR xviii YPBR xv YPBR xvi YPBR xvii YPBR xviii YPBR xvi YPBR xvii YPBR xviii YPBR xvii YPBR xviii YPBR xvii YPBR xviii YPBR xviii YPBR xviii P.No Part Name Body Bonnet Reflex Glass Tightening Part Carbon Steel Borosilicate Grafit.+Gal. St. Steel Borosilicate Grafit A - 0. DN0 assembly flange is used according to DIN EN 09-/. Distance between flanges can be lengthened about 0 mm. This point should be specified in the order.

7 Level Gauges Type: YUPR PN0 Bars, C (steam) 0 Bars, 0 C (other fluids) 0 - mm Level Gauge Type Distance Between Flanges M (mm) Body Length K(mm) Observation Length S (mm) YUPR IV YUPR V YUPR VI YUPR VII YUPR VIII YUPR IX YUPR xiv YUPR xv YUPR xvi YUPR xvii YUPR xviii YUPR xv YUPR xvi YUPR xvii YUPR xviii YUPR xvi YUPR xvii YUPR xviii YUPR xvii YUPR xviii YUPR xvii YUPR xviii YUPR xviii YUPR xviii P.No Part Name Carbon Steel St. Steel Body Bonnet Reflex Glass U Stud Nut Mica Borosilicate.+Gal..+Gal. Mica*,0,0 Borosilicate A - 0. A - 0. Mica* * It is optional (depending on application). DN0 assembly flange is used according to DIN EN 09-/. Distance between flanges can be lengthened about 0 mm. This point should be specified in the order.

8 Level Gauges Type: YMPT PN0 0 - mm Level Gauge Type Distance Between Flanges M (mm) Body Length K(mm) Observation Length S (mm) YMPT IV YMPT V YMPT VI YMPT VII YMPT VIII YMPT IX YMPT xiv YMPT xv YMPT xvi YMPT xvii YMPT xviii YMPT xv YMPT xvi YMPT xvii YMPT xviii YMPT xvi YMPT xvii YMPT xviii YMPT xvii YMPT xviii YMPT xvii YMPT xviii YMPT xviii YMPT xviii P.No Part Name Carbon Steel Body Bonnet Transparent Glass Nut Borosilicate Grafit.+Gal Mica Mica* St. Steel Borosilicate Grafit A - 0 Mica* * It must be absolutely used for hot and agressive fluids. DN0 assembly flange is used according to DIN EN 09-/. Distance between flanges can be lengthened about 0 mm. This point should be specified in the order.

9 Level Gauges Type: YUPT PN00 0-mm Level Gauge Type Distance Between Flanges M (mm) Body Length K(mm) Observation Length S (mm) YUPT IV YUPT V YUPT VI YUPT VII YUPT VIII YUPT IX YUPT xiv YUPT xv YUPT xvi YUPT xvii YUPT xviii YUPT xv YUPT xvi YUPT xvii YUPT xviii YUPT xvi YUPT xvii YUPT xviii YUPT xvii YUPT xviii YUPT xvii YUPT xviii YUPT xviii YUPT xviii P.No Part Name Carbon Steel St. Steel Body Bonnet Transparent Glass Nut Mica Borosilicate.+Gal. Mica* Borosilicate A - 0 Mica* * It must be absolutely used for hot and agressive fluids. DN0 assembly flange is used according to DIN EN 09-/. Distance between flanges can be lengthened about 0 mm. This point should be specified in the order.

10 Technical Dimensions Yakacık Reflex and Transparent Glasses Reflex Glasses A, B, H, All dimensions are in (mm) Dimension Type A Weight gr Type B Weight gr Type H Weight gr YAKACIK Reflex Glasses Application Pressures and Temperatures Type A ) Type B ) Type H Fluids with no corrosive effect on glass (oil, hydrocarbon etc.) Fluids with significant corrosive effect on glass (saturated steam etc.) ) We recommend transparent glass with transparent mica shield for pressures bars and above. Transparent Glasses A, B, H, TA All dimensions are in (mm) Dimension Type A Weight gr Type B Weight Type H Weight Type TA gr gr Weight gr YAKACIK Transparent Glasses Application Pressures and Temperatures Type A ) Type B ) Type H Type TA ) Fluids with no corrosive effect on glass (oil, hydrocarbon etc.) Fluids with significant corrosive effect on glass (saturated steam etc.) ) We recommend transparent glass with transparent mica shield for pressures bars and above. ) It can be used TA I. for the steam pressures higher than 0 bars. ) TA glasses can only be used with mica.

11 Manometer Cock ABL Cock ( Port) P.No Part Name Steel Stainless Cock Body Piston AB Ring Tightening Nut Ck.0 Split Ring Ms Lever St Disc.+Gal. 00 Stainless

12 Manometer Cock ABL Cock ( Port) P.No Part Name Steel Stainless Cock Body Piston AB Ring Tightening Nut Ck.0 Splint Ring Ms Lever St Disc.+Gal. 00 Stainless

13 Manometer Cock ABL Cock ( Port) P.No Part Name Steel Stainless Cock Body Piston AB Ring Tightening Nut Split Ring Ms Lever St Disc.+Gal.+Gal 00 Stainless.0

14 Manometer Cock ABL Cock ( Port) P.No Part Name Steel Stainless Cock Body Piston AB Ring Tightening Nut Split Ring Ms Lever St Disc.+Gal.+Gal 00 Stainless.0

15 Manometer Cock D - ABL Bottom Cock P.No Part Name Steel Stainless Adaptor Gasket Nut Nut Gasket 00.+Gal Top Body.09.0 D Flanged Cock Body.09.0 Stud 00 Tightening Nut Drain Adaptor Gasket AB Ring Tightening Nut St 00 Sealing Ring Piston.0 Split Ring Ms Lever Disc Piston AB Split Ring 00 St.+Gal.+Gal Nut 00 D Gasket AB Body Ck Disc.0 Ms AB Ring Tightening Nut 00 Lever St.+Gal. Stainless.0.0

16 Manometer Cock D - ABL Bottom Cock P.No Part Name Steel Stainless Adaptor Gasket Nut Nut Gasket 00.+Gal Top Body.09.0 D Flanged Cock Body.09.0 Stud 00 Tightening Nut Drain Adaptor Gasket AB Ring Tightening Nut Sealing Ring Piston.0 Split Ring Ms Lever Disc 00 St.+Gal.+Gal Nut 00 D Gasket AB Cock Body.09.0 Stainless.0.0.0

17 Manometer Cock D - Body Upper Cock P.No Part Name Steel Stainless Stainless Adaptor Nut 00 Top Body.09.0 D Flanged Cock Body.09.0 Gasket Stud 00 Nut Gasket Blind Nut Gasket.0.0.+Gal 00 Sealing Ring Tightening Nut 00 AB Ring Split Ring Ms Piston.0.+Gal Disc.+Gal Lever St Nut 00

18 Parameters Used for Orders It is important that you should specify the parameters stated below to choose the suitable Level Gauge. Please contact us for unclear issues. - Level Gauge Type - Quantity - Dimensions - Max. Operating Pressure - Max. and Min. Operating Temperatures - Fluid Type Water, hot water, air, gas, steam, LPG, oil, thermal oil, acid, base, etc. - Field of Application - Special requests You can use the following encoding system in your orders. Example: YLP.F..00 PBR xv Flanged PN Level Gauge Product Code YPBR - YLP YUPR - YLU YMPT - YLM YUPT - YLT Material Code Cast Iron Cast Steel Assembly Type F Flanged YLP F IV -0 V -0 VI -0 VII -0 VIII -0 IX -09 xiv - xv - xvi - xvii- xviii - 0 Dimensions 00 xv - xvi - xvii- xviii - xvi - xvii- xviii - xvii- xviii - xvii- xviii - xviii xviii Norms 00 DIN

19 YAKACIK VALF Products Piston Valves DN - DN0 Balanced Piston Valves DN - DN00 YX - GT Ring Sets DN - DN00 Bellows Sealed Globe Valves DN - DN00 Globe Valves DN - DN00 Boiler Blowdown Valves DN - DN0 Ball Valves DN - DN00 T Type Strainers DN - DN00 Y Type Strainers DN - DN00 Expansion Joints DN - DN00 Cryogenic Valves DN - DN0 Manometer Cocks /'' Ball Valves (for natural gas) DN - DN00 Ball Valves Monoball DN - DN00 Check Valves DN - DN00 Disc Check Valves DN - DN00 Dual Plate Check Valves DN0 - DN00 Butterfly Valves DN - DN00 Level Gauges YPBR - YUPR - YUPT Transparent Gauge Glass Safety Valves DN 0x - DN 00x0 Fire Hydrants DN0 - DN0 ISO AD W 0 QUALITY MANAGEMENT SYSTEM MANUFACTURING QUALIFIED CERTIFICATE CE 0 PED 9/ EC / III MODULE H FIRE SAFE FIRE SAFE TPED 99 EAC BALL VALVES - CAST STEEL PISTON VALVES - CAST STEEL TRANSPORTABLE PRESSURE EQUIPMENT DIRECTIVE ALL PRODUCTS YAKACIK VALF SAN. ve TİC. A.Ş. İstanbul Deri Organize Sanayi Bölgesi Tabak Sk. No: N- Özel Parsel 9 Tuzla / istanbul / TÜRKİYE Tel: (Pbx) Faks: info@yakacikvalf.com.tr Ankara Gsm : Kocaeli Gsm : +90 İzmir Gsm : Trakya Gsm :