Argo and Delphi. Delphi. Argo span-wire installation. Argo. products.iguzzini.com/argo_line products.iguzzini.com/delphi_line

Size: px
Start display at page:

Download "Argo and Delphi. Delphi. Argo span-wire installation. Argo. products.iguzzini.com/argo_line products.iguzzini.com/delphi_line"

Transcription

1 Delphi Argo span-wire installation Argo La venaria ø1411 anello ø900 ufo crown ø664 iteka 195x270 platea 250x370 flaminia x x x620 wow archilede archilede 412x x765 lavinia lavinia 333x x x x732 iroad iroad 313x x585 Piazza d armi Santiago del Cile - Chile Architectural project: Rodrigo Pérez de Arce & Sebastián Bianchi Lighting project: Tallerdos (Ramón López & Matías López) Photo: Cristian Barahona M. ø argo 369argo argo delphi 330 delphi 451 ø369 ø delphi 330 delphi products.iguzzini.com/argo_line products.iguzzini.com/delphi_line 399

2 Compositions Pole-top Linear arms single pole-top double pole-top triple pole-top linear arm L=900 with intermediate attachment linear arm L=900 (double composition) Shaped poles pole with single arm pole with double arm conical curved pole conical curved pole with intermediate attachment wall attachment 400 products.iguzzini.com/argo_line products.iguzzini.com/delphi_line

3 Features 03 IP66 IK08/IK09 Street lighting system for use with LEDs. Pole or wall-mounted installation. Fitting has an optical assembly, pole, arm (single or double) and pole-top. Die-cast aluminium optical assembly and lid; sodium-calcium tempered sealing glass, thickness 5 mm; 50 Shore black silicone gasket; polished anodized reflector made of 99.93% superpure aluminium. Die-cast aluminium pole-top with single and double attachment for poles ø 60, 76, 102, 120 mm, triple ø 102, 120 mm. Die-cast aluminium lateral attachment for tapered poles with diameter from 46 to 76 mm. No upward emission of the light flow. Adjustable optical assembly. High visual comfort. High performance optics (Opti Smart) and uniform light distribution. No photobiological risk. This luminaire is in the Exempt Group (no risk linked to infrared, blue light and UV radiation) in accordance with EN 62471:2008. The luminaire has luminous flux emission fully programmable directly from the product driver. The driver allows the use of 3 fixed profiles (1/2/3) and one variable profile (4) for different output lumen levels and different powers. Profile 1 fixed to 375mA Profile 2 fixed to 450mA Profile 3 fixed to 525mA Profile 4 variable to 350mA. Compatibility with Telemanagement systems thanks to Power Supply, dual-operation Flux regulator and LED Driver DALI (0-10V/1-10V) compatible with the systems on the market. Common mode surge protection up to 10KV. An active control system modifies the current intensity to preserve the luminous efficacy and the lifetime of the LEDs under any ambient temperature conditions. Replaceable driver unit and control gear. All external screws are in stainless steel. Tool-free optical assembly opening Automatic door lock Optics h I ST - Road optics ST1 I = 4h / d = 1 Intensity Class: G4 h A - Asymmetric optics A60 h = 7 / d = 2 L ST1.2 I = 4h / d = 1,2 Intensity Class: G4 L A45C h = 7 / d = 1,6 d = L/h h = Installation height L = Width of area to be lit I = Spacing between poles ST1C I = 3,7h / d = 1 Intensity Class: G6 d = L/h h = Installation height L = Width of area to be lit ST0.8C I = 3,7h / d = 1 Intensity Class: G6 Energy saving LED Single Chip Colour stability Mac Adam <3 Life h L80 B10 Color temperature: Neutral white 4000K Warm white 3000K lumen lm LED HIT/HST HME W 83W 63% 92W 68% W 117W 55% 150W 65% W 170W 60% 275W 75% (4000K) LED energy saving compared with traditional lamps The system life is calculated at Ambient Temperature (Ta) 25 C products.iguzzini.com/argo_line products.iguzzini.com/delphi_line 401

4 Argo 04 black 15 grey accessories 244,5 light source W* min W* max lm min lm max Multipower with midnight recognition 30 W 42 W BL W 72 W BL W 42 W BP W 72 W BP Polycarbonate screen IK10 USB pen profiler Complete with cable and battery BZ43 24 for BL86-BL87-BL88-BL89 BL90-BL91-BL92-BL93-BL94 BP26-BP27-BP28-BP29-BP30 BP31-BP32-BP33-BP34 BZX1 04 ø K - CRI 70 - ST1.2 optic 38 W 51 W BL W 81 W BL K - CRI 70 - ST1.2 optic 38 W 51 W BP W 81 W BP K - CRI 70 - ST0.8C optic 30 W 42 W BL K - CRI 70 - ST0.8C optic 30 W 42 W BP K - CRI 70 - ST1C optic 37 W 51 W BL W 81 W BL K - CRI 70 - ST1C optic 37 W 51 W BP W 81 W BP K - CRI 70 - A60 optic 58 W 81 W BL K - CRI 70 - A60 optic 58 W 81 W BP K - CRI 70 - A45C optic 58 W 81 W BL K - CRI 70 - A45C optic 58 W 81 W BP The BL87-BL89-BL92-BL93-BL94-BP27-BP29-BP32-BP33-BP34 codes can be used with the Profiles 1-4 at a maximum environment temperature of 40 C and with the Profiles 2-3 at a maximum environment temperature of 25 C. The BL88- BL91-BP28-BP31 codes can be used with the Profiles at a maximum environment temperature of 40 C and with the Profile 3 at a maximum environment temperature of 25 C. Multipower DALI 17 W 23 W BP W 23 W BP The output lumen and power value of the systems refer to the Profiles with the greatest light efficiency (Profile 1) and to the profile with maximum output flux (Profile 3). The values of other profiles can be consulted in the online catalogue: products.iguzzini.com/code Technical data may change with technological evolution. For updated data please refer to our on-line catalogue.

5 Delphi 04 black 15 grey light source W* min W* max lm min lm max Multipower with midnight recognition light source W* min W* max lm min lm max Multipower with midnight recognition 30 W 42 W BL W 91 W BM W 72 W BL W 96 W BM W 42 W BP W 72 W BP W 91 W BP W 96 W BP K - CRI 70 - ST1.2 optic 38 W 51 W BL K - CRI 70 - ST1.2 optic 80 W 94 W BM W 81 W BL K - CRI 70 - ST1.2 optic K - CRI 70 - ST1.2 optic 80 W 95 W BP W 51 W BP W 81 W BP K - CRI 70 - ST1C optic 79 W 95 W BM K - CRI 70 - ST0.8C optic 30 W 42 W BL K - CRI 70 - ST1C optic 79 W 95 W BP K - CRI 70 - ST0.8C optic 30 W 42 W BP K - CRI 70 - A60 optic 86 W 103 W BM K - CRI 70 - ST1C optic 37 W 51 W BL W 81 W BL K - CRI 70 - ST1C optic 37 W 51 W BP W 81 W BP K - CRI 70 - A60 optic 58 W 81 W BL K - CRI 70 - A60 optic 3000K - CRI 70 - A60 optic 86 W 103 W BP K - CRI 70 - A45C optic 86 W 103 W BM K - CRI 70 - A45C optic 86 W 103 W BP Can be used only with Profiles and at a maximum environment temperature of 25 C. The BM11-BP51 code can also use the Profile W 81 W BP K - CRI 70 - A45C optic 58 W 81 W BL K - CRI 70 - A45C optic 58 W 81 W BP The BL78-BL80-BL83-BL84-BL85-BP18-BP20-BP23-BP24-BP25 codes can be used with the Profiles 1-4 at a maximum environment temperature of 40 C and with the Profiles 2-3 at a maximum environment temperature of 25 C. The BL79-BL82-BP19-BP22 codes can be used with the Profiles at a maximum environment temperature of 40 C and with the Profile 3 at a maximum environment temperature of 25 C. Multipower bi-energy with pilot cable 17 W 23 W BU W 23 W BU DALI Multipower 17 W 23 W BP W 23 W BP The output lumen and power value of the systems refer to the Profiles with the greatest light efficiency (Profiles 1-4) and to the profile with maximum output flux (Profiles 2-3). The values of other profiles can be consulted in the online catalogue: accessories Polycarbonate screen IK10 USB pen profiler Complete with cable and battery BZ41 24 for BL77-BL78-BL79-BL80 BL81-BL82-BL83-BL84-BL85 BP17-BP18-BP19-BP20-BP21 BP22-BP23-BP24-BP25 BZX1 04 Technical data may change with technological evolution. For updated data please refer to our on-line catalogue. products.iguzzini.com/code 403

6 pole-top installation on cylindrical poles ø pole attachment single 60 BD BD BD double 60 BD BD BD triple 102 BD installation with arms on cylindrical poles length ø pole linear BZ BZ The counter flange must be ordered, to secure the arm to the pole. counter flange 102 BZ The arms can be installed individually or in double composition. To be ordered to secure the linear arm without tie rod to the pole. Not required when installing two opposite arms. tilted with tie rod BZ Can be used only with Argo and Delphi small body. intermediate attachment 102 BD wall-mounted installation wall attachment BD products.iguzzini.com/code

7 cylindrical poles for pole-top installation of 1/2 optical assemblies cylindrical poles for pole-top installation of 3 optical assemblies or for arms h off-ground ø pole ø shank buried * / / / with plate / / / * Not for use in the installation of the large optical assembly h off-ground ø pole buried / / / / with plate / / / / / / The technical specifications of the poles are presented on page 457. Fixing plate with anchor bolts to be ordered separately (page 465). installation on shaped poles shaped poles ø lateral attachment lateral attachment from 46 to 76 BZC buried h off-ground ø pole ø lateral attachment with single arm with double arm decorative point with LED LED Blue BZC5 01 LED Neutral white BZC6 01 with plate with single arm For curved conical poles with double arm curved conical max max 60 * max max 60 * * Versions with intermediate attachment The technical specifications of the poles are presented on page 457. Fixing plate with anchor bolts to be ordered separately (page 465). products.iguzzini.com/code 405

8 Argo span-wire installation Features 03 IP66 IK08 Street lighting luminaire for use with LEDs. Pendant installation. Made up of optical assembly and fixing system. Die-cast aluminium optical assembly and lid; sodium-calcium tempered sealing glass, thickness 5 mm; 50 Shore black silicone gasket; polished anodized reflector made of 99.93% superpure aluminium. Die-cast aluminium fixing system with anchoring system to AISI 304 stainless steel wire. Attached on cables/wires with diameter from 6 to 12 mm. Stainless steel anti-fall safety system. No upward emission of the light flow. Adjustable optical assembly. Common mode surge protection up to 10KV. Versions with DALI and bi-energy (100% - 50%) control gear. Replaceable LED unit. Replaceable driver unit and control gear. All screws are A2 stainless steel. Double-adjustability Optic I STM1 - Pendant road optic for vehicular traffic light source W* min W* max lm min lm max DALI Multipower 4000K - CRI 70 - STM1 optic h L STM1 I = 4h / d = 1 Intensity Class: G4 30 W 41 W BU K - CRI 70 - STM1 optic 30 W 41 W BU51 15 Multipower bi-energy with pilot cable K - CRI 70 - STM1 optic d = L/h h = Installation height L = Width of area to be lit I = Spacing between poles ø W 41 W BU K - CRI 70 - STM1 optic 30 W 41 W BU53 15 Multipower with midnight recognition 4000K - CRI 70 - STM1 optic 58 W 81 W BU54 15 USB pen profiler Complete with cable and battery BZX K - CRI 70 - STM1 optic 58 W 81 W BU55 15 The output lumen and power value of the systems refer to the Profiles with the greatest light efficiency (Profile 1) and to the profile with maximum output flux (Profile 3). The values of other profiles can be consulted in the online catalogue: Bay View Terrace - Claremont, Australia 406 products.iguzzini.com/argo_line Technical data may change with technological evolution. For updated data please refer to our on-line catalogue. Architectural project and Design: AECOM Australia Pty Ltd Electrical Engineering: AECOM Australia Pty Ltd Lighting project: Mervin van der Linde Photographer: Ron Tan