GRAYS HARBOR COUNTY TECHNICAL ASSISTANCE BULLETIN

Size: px
Start display at page:

Download "GRAYS HARBOR COUNTY TECHNICAL ASSISTANCE BULLETIN"

Transcription

1 GRAYS HARBOR COUNTY TECHNICAL ASSISTANCE BULLETIN 36 RESIDENTAL ENGERY CODE COMPLIANCE WORKSHEETS The attached compliance fms can be completed manually by visiting and using the electronic versions. Ensure that all applicable fields are completed and that the crect areas and U-facts are used. The residential chapters apply to single family dwellings (IRC definition) and multifamily is located in the commercial sections of the WSEC. Duct leakage testing of existing ducts required when a furnace air handler is replaced (there are exceptions). A certificate of energy listing features of the residence is required to be posted at near the electrical panel. Design temperatures f various Washington locations are now listed in Chapter 3. The substantial contact with the surface being insulated language has an exception f insulation location in certain types of flo systems in der to keep ducts within the conditioned space. Conditioned and unvented attics are allowed under certain conditions. Building air leakage testing (with a blower do) is required. Programmable thermostats are required on all primary heating systems with a 10 degree dead-band when capable of providing both heating and cooling. Strip heat lock-out devices required on heat pumps when the space conditioning requirements can be met with the heat pump alone. Ducts located in ceiling and flo space cannot displace required insulation levels. Building cavities cannot be used as ducts. Duct leakage testing required f all new HVAC systems with ducts located in unconditioned spaces. An R-5 thermal break is required between below grade slab flos and foundation walls enclosing conditioned space. Residences must have 75% high efficacy luminaries (light fixtures). Spray foam with a minimum R-value of 3.6 per inch is deemed to comply with the required R-21 prescriptive requirement when installed in a 5.5 inch cavity. Garden type windows must now meet prescriptive energy compliance requirements. WSEC Prescriptive Wksheet (2010 Edition) WSUEP Copyright 2010

2 Prescriptive Energy Code Compliance f All Climate Zones in Washington Project Infmation Contact Infmation This project will use the requirements of the Prescriptive Path below and incpate the the minimum values listed. In addition, based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Authized Representative Date Fenestration U-Fact b Skylight U-Fact Glazed Fenestration SHGC b,e Ceiling Wood Frame Wall g,k,l Mass Wall R-Value i Flo Below Grade Wall c,k Slab d R-Value & Depth 1. Small Dwelling Unit: points Dwelling units less than 1500 square feet in conditioned flo area with less than 300 square feet of fenestration area. Additions to existing building that are less than 750 square feet of heated flo area. 2. Medium Dwelling Unit: 1.5 points All dwelling units that are not included in #1 #3, including additions over 750 square feet. 3. Large Dwelling Unit: 2.5 points Dwelling units exceeding 5000 square feet of conditioned flo area. Option All Climate Zones R-Value a 10/15/21 int + TB U-Fact a Credit(s) 1a Efficient Building Envelope 1a 1b Efficient Building Envelope 1b 1c Efficient Building Envelope 1c 2.0 2a Air Leakage Control and Efficient Ventilation 2a 2b Air Leakage Control and Efficient Ventilation 2b 2c Air Leakage Control and Efficient Ventilation 2c 1.5 3a High Efficiency HVAC 3a 3b High Efficiency HVAC 3b 3c High Efficiency HVAC 3c 2.0 3d High Efficiency HVAC 3d 4 High Efficiency HVAC Distribution System 5a Efficient Water Heating 5b Efficient Water Heating Renewable Electric Energy *1200 kwh 0.0 Total Credits 0.00 *Please refer to Table R406.2 f complete option descriptions j *Table R and Table R Footnotes included on Page 2. Each dwelling unit in one and two-family dwellings and townhouses, as defined in Section of the International Residential Code shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: Table R406.2 Summary Description 21 int 21/21 h 30 g 10, 2 ft

3 Table R Footnotes F SI: 1 foot.= mm, ci.= continuous insulation, int.= intermediate framing. a R-values are minimums. U-facts and SHGC are maximums. When insulation is installed in a cavity which is less than the label design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-fact column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC f such skylights does not exceed c "10/15/21.+TB" means R-10 continuous insulation on the exteri of the wall, R-15 on the continuous insulation on the interi of the wall, R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interi of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interi of the basement wall plus R-5 continuous insulation on the interi exteri of the wall. "10/13" means R-10 continuous insulation on the interi exteri of the home R- 13 cavity insulation at the interi of the basement wall. "TB" means thermal break between flo slab and basement wall. d R-10 continuous insulation is required under heated slab on grade flos. See R e There are no SHGC requirements in the Marine Zone. f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R g Reserved. h First value is cavity insulation, second is continuous insulation insulated siding, so "13.+5" means R-13 cavity insulation plus R-5 continuous insulation insulated siding. If structural sheathing covers 40 percent less of the exteri, continuous insulation R-value shall be permitted to be reduced by no me than R-3 in the locations where structural sheathing is used to maintain a consistent total sheathing thickness. i The second R-value applies when me than half the insulation is on the interi of the mass wall. j F single rafter- joist-vaulted ceilings, the insulation may be reduced to R-38. k Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. l Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from this insulation requirement. Table R Footnote a Nonfenestration U-facts shall be obtained from measurement, calculation an approved source as specified in Section R

4 Glazing Schedule Project Infmation Contact Infmation R Exception (15 sq. ft. max.) Vertical Glazing (Windows and glazed dos) Plan Component Glazing Width Height Glazing ID Description Ref. U-fact Qt. Feet Inch Feet Inch Area UA

5 Sum of Area and UA Area Weighted U = UA/Area 0.00

6 Simple Heating System Size: Washington State This heating system sizing calculat is based on the Prescriptive Requirements of the 2012 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculat will calculate heating loads only. ACCA procedures f sizing cooling systems should be used to determine cooling loads. The glazing (window) and do ption of this calculat assumes the installed glazing and do products have an area weighted average U-fact of The incpated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs f each section, some values will be calculated f you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at (360) f assistance. Project Infmation Contact Infmation Heating System Type: Fced Air Furnace Heat Pump To see detailed instructions f each section, place your curs on the wd "Instructions". Design Temperature Instructions Design Temperature Difference ( T) T = Indo (70 degrees) - Outdo Design Temp Area of Building Conditioned Flo Area Instructions Conditioned Flo Area (sq ft) Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) Glazing and Dos U-Fact X Area = UA Instructions Insulation Attic U-Fact X Area = UA Single Rafter Joist Vaulted Ceilings U-Fact X Area UA Above Grade Walls (see Figure 1) U-Fact X Area UA Flos U-Fact X Area UA Below Grade Walls (see Figure 1) U-Fact X Area UA Slab Below Grade (see Figure 1) F-Fact X Length UA Slab on Grade (see Figure 1) F-Fact X Length UA Location of Ducts Instructions Duct Leakage Coefficient Sum of UA Figure 1. Above Grade Below Grade Envelope Heat Load Btu / Hour Sum of UA X T Air Leakage Heat Load Btu / Hour Volume X 0.6 X T X.018 Building Design Heat Load Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output Btu / Hour Building and Duct Heat Loss X 1.40 f Fced Air Furnace Building and Duct Heat Loss X 1.25 f Heat Pump (07/01/13)

7 WASHINGTON STATE ENERGY CODE, RESIDENTIAL PROVISIONS TABLE ENERGY CREDITS (DEBITS) OPTION DESCRIPTION CREDIT(S) 1a EFFICIENT BUILDING ENVELOPE 1a: Prescriptive compliance is based on Table R with the following modifications: Fenestration U.= 0.28 Flo R-38 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab Compliance based on Section R : Reduce the Total UA by 5%. 1b EFFICIENT BUILDING ENVELOPE 1b: Prescriptive compliance is based on Table R with the following modifications: Fenestration U.= 0.25 Wall R-21 plus R-4 Flo R-38 Basement wall R-21 int plus R-5 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab Compliance based on Section R : Reduce the Total UA by 15%. 1c EFFICIENT BUILDING ENVELOPE 1c: Prescriptive compliance is based on Table R with the following modifications: Fenestration U.= 0.22 Ceiling and single-rafter joist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Flo R-38 Basement wall R-21 int plus R-12 ci Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab Compliance based on Section R : Reduce the Total UA by 30%. 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: Compliance based on R : Reduce the tested air leakage to 4.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M of the International Residential Code shall be met with a high efficiency fan (maximum 0.35 watts/cfm), not interlocked with the furnace fan ventilation systems using a furnace including an ECM mot are allowed, provided that they are controlled to operate at low speed in ventilation only mode. being selected and shall specify the option being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. 2.0

8 2b AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2b: Compliance based on Section R : Reduce the tested air leakage to 2.0 air changes per hour maximum and All whole house ventilation requirements as determined by Section M of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. 2c AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c: Compliance based on Section R : Reduce the tested air leakage to 1.5 air changes per hour maximum and All whole house ventilation requirements as determined by Section M of the International Residential Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of being selected and shall specify the maximum tested building air leakage and shall show the heat recovery ventilation system. 3a HIGH EFFICIENCY HVAC EQUIPMENT 3a: Gas, propane oil-fired furnace with minimum AFUE of 95% being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3b HIGH EFFICIENCY HVAC EQUIPMENT 3b: Air-source heat pump with minimum HSPF of 8.5 being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3c HIGH EFFICIENCY HVAC EQUIPMENT 3c: Closed-loop ground source heat pump; with a minimum COP of 3.3 Open loop water source heat pump with a maximum pumping hydraulic head of 150 feet and minimum COP of 3.6 being selected and shall specify the heating equipment type and the minimum equipment efficiency. 3d HIGH EFFICIENCY HVAC EQUIPMENT 3d: DUCTLESS SPLIT SYSTEM HEAT PUMPS, ZONAL CONTROL: In homes where the primary space heating system is zonal electric heating, a ductless heat pump system shall be installed and provide heating to at least one zone of the housing unit. being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4 HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM: a All heating and cooling system components installed inside the conditioned space. All combustion equipment shall be direct vent sealed combustion. Locating system components in conditioned crawl spaces is not permitted under this option. Electric resistance heat is not permitted under this option. Direct combustion heating equipment with AFUE less than 80% is not permitted under this option. being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwk

9 5a EFFICIENT WATER HEATING 5a: Water heating system shall include one of the following: Gas, propane oil water heater with a minimum EF of 0.62 Electric water heater with a minimum EF of and f both cases All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM less. All other lavaty faucets shall be rated at GPM less. b being selected and shall specify the water heater equipment type and the minimum equipment efficiency and shall specify the maximum flow rates f all showerheads, kitchen sink faucets, and other lavaty faucets. 5b EFFICIENT WATER HEATING 5b: Water heating system shall include one of the following: Gas, propane oil water heater with a minimum EF of 0.82 Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms 2000 kwh based on the Solar Rating and Certification Cpation (SRCC) Annual Perfmance of OG-300 Certified Solar Water Heating Systems Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Nthern Climate Specifications f Heat Pump Water Heaters Water heater heated by ground source heat pump meeting the requirements of Option 3c. being selected and shall specify the water heater equipment type and the minimum equipment efficiency and, f solar water heating systems, the calculation of the minimum energy savings. 6 RENEWABLE ELECTRIC ENERGY: F each 1200 kwh of electrical generation provided annually by on-site wind solar equipment a credit shall be allowed, up to 3 credits. Generation shall be calculated as follows: F solar electric systems, the design shall be demonstrated to meet this requirement using the National Renewable Energy Labaty calculat PVWATTs. Documentation noting solar access shall be included on the plans. F wind generation projects designs shall document annual power generation based on the following facts: The wind turbine power curve; average annual wind speed at the site; frequency distribution of the wind speed at the site and height of the tower. being selected and shall show the photovoltaic wind turbine equipment type, provide documentation of solar and wind access, and include a calculation of the minimum annual energy power production. a. Interi Duct Placement. Ducts included as Option 4 of Table R406.2 shall be placed wholly within the heated envelope of the housing unit. The placement shall be inspected and certified to receive the credits associated with this option. Exception: Ducts complying with this section may have up to 5% of the total linear feet of ducts located in the exteri cavities buffer spaces of the dwelling. If this exception is used the ducts will be tested to the following standards: Post-construction test: Leakage to outdos shall be less than equal to 1 CFM per 100 ft 2 of conditioned flo area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped otherwise sealed during the test. b. Plumbing Fixtures Flow Ratings. Low flow plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the following requirements: 1. Residential bathroom lavaty sink faucets: Maximum flow rate L/min ( gal/min) when tested in accdance with ASME A /CSA B Residential kitchen faucets: Maximum flow rate L/min (1.75 gal/min) when tested in accdance with ASME A /CSA B Residential showerheads: Maximum flow rate L/min (1.75 gal/min) when tested in accdance with ASME A /CSA B