SKYPORT HANGAR LOTS 8A & 9A PGA ARCHITECTS W E T A S K I W I N A L B E R T A SECTION AA HANGAR ONE SECTION BB. NOTE Heating - hydronic in-floor system

Size: px
Start display at page:

Download "SKYPORT HANGAR LOTS 8A & 9A PGA ARCHITECTS W E T A S K I W I N A L B E R T A SECTION AA HANGAR ONE SECTION BB. NOTE Heating - hydronic in-floor system"

Transcription

1

2

3 9'-0" SETION 80'-0" 8'-0" 4'-0" 11'-7" 6. 2x8 col. 7'-0" 60'-0" 38' x 8, x 4" conc apron 16" e/w 16" o.c. (with 1" fall) NOTE See elevations for windows at upper level 24'-0" future location of wc & laundry tub future 2x6 bearing wall HNGR ONE 48' x 18' IFOLD O/H DOOR 60'-0" ION cantlevered upper floor 36"x20" attic access OILER & PUMPS FOR IN FLOOR HETING NOTE Heating - hydronic in-floor system SETION 1'-4" 12'x14' high O/H door ELET PNEL collection sump-pit 36"x20" attic access 6, 2x8 col. 60'-0" 1'-4" 12'x14' high O/H door ELET PNEL hot & cold water supply collection sump-pit 3" dia sewer clean-out HNGR TWO 36"x20" attic access 6, 2x8 col. GROUND FLOOR GROUND FLOOR PLN W E T S K I W I N L E R T DTE 27 May

4 SETION 80'-0" 9'-0" 24'-4" 48x8" foundation wall 55'-8" 8'-0" 4'-0" 24"x24"x8" pad with 8"x8" pier to grade 7'-0" 10'-6" 8" 60'-0" SETION 14'-8" 38' x 8, x 4" conc apron 16" e/w buck for 3/0 door 4'-0" 48x8" foundation wall 6" ON PD (3500 lb) 18" E/W ONTROL 20' E/W 30"x 10" strip footing 1.5" rigid insul 2,15M t&b 10M o.c. 2'-6" 4'-0" 12" 3, 15M contin 10M 24" 4'-0" 12" 16" 3'-0" 3,15M t&b 10M o.c. 4, 15M contin 10M 24" 48x8" foundation wall buck for 48' hangar door check rough opening size SETION 4, 15M contin 10M 24" 21'-6" 2'-0" buck for 12/0 O/H door 10' x 4" O trench drain set 1" below floor slab IN FLOOR HETING OILER, TNKS & PUMPS ELET PNEL 14'-0" 12" 6" buck for 3/0 door 2'-0" 18'-0" hot & cold water supply 3" dia sewer clean-out buck for 3/0 door 60'-0" buck for 12/0 O/H door FOUNDTION PLN FOUNDTION PLN buck for 50' hangar door check rough opening size DTE 27 May W E T S K I W I N L E R T

5 30-10d common 3" nails (0.148"dia) Simpson Strong Tie STHD14 to edge of base of shear panels SHNER PNELS 5/8 D.F. ply each side dble 2x8 blocking at all edges dble bottom plate or blocking at bottom & top plates 3": common 4" o.c. & glue all adges 2, 24"x 24" wall vent into attic space 2, 24"x 24" wall vent into attic space dble studs each side dble studs each side selected 42" high guard rail selected 42" high guard rail SHER PNEL SHER PNEL GROUND SIDE ELEVTION Simpson LST36-1 1/4" x 36" x 18g straps over top of gang trusses. STHD14 at base 2, 24"x 24" wall vent into attic space 2, 24"x 24" wall vent into attic space Simpson LST36-1 1/4" x 36" x 18g straps over top of gang trusses. STHD14 at base SHER PNEL SHER PNEL IR SIDE ELEVTION ELEVTIONS W E T S K I W I N L E R T DTE 27 May

6 D D D D D EST ELEVTION D D D D D WEST ELEVTION ELEVTIONS W E T S K I W I N L E R T DTE 27 May

7 triple stud in front wall 42x53 42x53 42x53 71x59.5 D 36x72 36x72 36x72 36x72 WINDOW SHEDULE 1/4" = 1'-0" D 24x24 1/2" lag 12" o.c. staggered to triple stud in wall take 3/4" ply to inside edge of main front wall on both sides stagger 8" o.c. 2x6 end wall framing 3/4" ply to b/s attach with framing screws METL ROOFING 1/2" PLYWOOD ENGINEERED WOOD TRUSSES@ 24" O.. R40 LOOSE FILL INSULTION 6mil POLY V.. 1x4 24" O.. METL LDDING (5/8" type X & 6mil poly V.. dryall at apartment area) floor joists in hangers 4 girder trusses spiked together attic hatch 1/2" drywall smoke stop 60' max attic hatch UPPER FLOOR EXTENSION SUPPORT no scale metal clad ceiling 5/8" type X dryall 8'-0" wall type W3 future upper level not in contract wall type W2 SETION SETIONS W E T S K I W I N L E R T DTE 27 May

8 METL ROOFING 1/2" PLYWOOD ENGINEERED WOOD 24" O.. R40 LOOSE FILL INSULTION 6mil POLY V.. 1x4 24" O.. METL LDDING (5/8" type X & 6mil poly V.. dryall at apartment area) METL ROOFING 1/2" PLYWOOD ENGINEERED WOOD TRUSSES@ 24" O.. R40 LOOSE FILL INSULTION 6mil POLY V.. 1x4 24" O.. METL LDDING (5/8" type X drywall & 6mil poly V.. at apartment area) 12 2 layers type 5/8" type X drywall 2x4 16" o.c. 2 layers type 5/8" type X drywall 2.5 1/2" drywall smoke stop at 60' (max) 1/2" drywall smoke stop at 60' (max) WLL LEL W1 2 1/2 HRS 2x8 16" o.c. 5/8" type X dryall (future suite area only) 2 layers 5/8" type X drywall 2x8 16" o.c. 1" gap 2x8 16" o.c. 2 layers 5/8" type X drywall 5/8" type X dryall (future suite area only) WLL LEL W1 2 1/2 HRS future upper level not in contract 18'-0" 18'-0" future upper level not in contract 8'-0" 6" ON SL 18" E/W ONTROL 20' E/W 6 mil POLY V.. 8" OMPTED HRDFILL TO 98% PROTOR 6" ON SL 18" E/W ONTROL 20' E/W 6 mil POLY V.. 8" OMPTED HRDFILL TO 98% PROTOR 8'-0" GRDE SUPPORTED ONRETE SL RING on each side wall (W1) and each centre wall 2 sets of strapping 18g x 2", wrap over and under plates and nail at stud locations SETION FINISHED FLOOR LEVEL THE UILDING PD TO E STRIPPED, REMOVING SURFIIL TOPSOIL, VEGETTION OR OTHER UNSUITLE MTERIL EXPOSING THE UNDERLYING LY OR SND SUGRDE. THE DEPTH OF THE STRIPPING TO REMOVE THE TOPSOIL IS ESTIMTED TO E 18". THE UILDING PD TO E GRDED LEVEL, SRIFIED ND REOMPTED TO 98% STNDRD PROTOR MXIMUM DRY DENSITY (SPMDD) T OR SLIGHTLY OVER OPTIMUM MOISTURE ONTENT. FILL MTERIL UT FROM THE HIGH RES OF THE UILDING PD ND USED TO RISE THE GRDE OF THE LOW RES TO E OMPTED TO 98% SPMDD T 0% TO 2% OVER OPTIMUM MOISTURE ONTENT IN LIFTS NOT EXEEDING 6" IN OMPTED THIKNESS. GRNULR MTERILS SPEIFITION 3/4" MX. SIZED RUSHED GRVEL 1. MTERIL TO E SOUND, HRD, DURLE, PRTILES FREE OF ELONGTED PIEES, ORGNI, OR OTHER FOREIGN MTTER. 2. LIGHTWEIGHT PRTILES NOT TO EXEED 2% WHEN TESTED IN HEVY LIQUID WITH RELTIVE DENSITY OF MTERIL TO E UNIFORMILY GRDED ETWEEN THE FOLLOWING LIMITS. SIEVE SIZE % PSSING approx 45º nailing strapping 5" conc slab 4" granular fill proposed level raw grade filter cloth 4" 4" IMPORTED FILL MTERIL IF REQUIRED MY E OMPRISED OF LOW TO MEDIUM PLSTI LY TILL OR GRNULR MTERIL SUH S WELL GRDED SND OF GRVEL. IMPORTED FILL TO E OMPTED TO 98% SPMDD T 0% TO 2% OVER OPTIMUM MOISTURE ONTENT IN LIFTS NOT EXEEDING 6" IN OMPTED THIKNESS. THE UPPER 6" OF THE SUGRDE (FINL LIFT) TO OMPTED TO 100% SPMDD T 0% TO 2% OPTIMUM MOISTURE ONTENT. 3/4" 100 3/16" /16" um um MTERIL TO HVE LIQUID LIMIT OF THE MINUS 315 um FRTION NOT GRETER 25% ND PLSTIITY INDEX NOT GRETER THN 6%. nailing ONRETE FLOOR SL TO E UNDERLIN DIRETLY Y VPOUR RRIER ND 6" (MIN.) LYER OF RUSHED GRVEL (3/4" MX. SIZE) OMPTED TO 100% SPMDD. 5. MTERIL TO HVE RUSHED FES OUNT OF PLUS 3/16" MTERIL OF T LEST 40%. 6. RUSHED GRVEL TO E OMPTED TO 100% MX. STNDRD PROTOR DENSITY SETION & ODE NLYSIS W E T S K I W I N L E R T 27 DTE May

9 220 switching & circuit for bi-fold door $ line of future 2nd floor telephnone outlet cable outlet duplex outlet wall mounted light fixture ceiling mounted fixture $ $ switch wire & install 3 fixtures to u/s of 2nd fl. balcony temporary lights on separate circuit ceiling fan with controller 4 lamp T5 HNGR llow for 100 amp service to future upper level apartment OILER ELET PNEL $$$ 30amp 220 $ ELET PNEL GROUND FLOOR ELETRIL PLN W E T S K I W I N L E R T DTE 27 May 2015 E1

10 24'-0" 24'-0" 2'-0" 10'-0" 10'-0" 2'-4" 2'-4" 11'-4" 12'-8" 5'-4" DEK EDRM 2 EDRM 1 60"x36" shower TH 7'-4" 11'-4" 7'-2" 3'-0" frig pantry 2'-8" W 7'-0" 11'-7" 10'-0" LNDRY washer ldry tub dryer 9'-0" 45'-4" 9'-8" d/w 4'-3" 45'-4" 5'-6" LIVING / DINING KITHEN 10'-4" FURN ENTRY HWT IN FLOOR HETING OILER, TNKS & PUMPS 16'-2" up 16 risers 7'-10" 12'-3" 17'-6" gas fireplace pony wall down 16 risers 7'-10" W1 W1 3'-10" 4'-7" 3'-10" 10' x 4" O trench drain RV Y 24'-0" ELET PNEL 3" dia sewer clean-out 14'-8" 14'-8" 18'-0" FUTURE DEVELOPMENT W E T S K I W I N L E R T DTE 27 May 2015

11 W E T S K I W I N L E R T

12 HNGR HNGR MEH FURN HWT MEH HWT FURN 60"x36" shower TH frig KITHEN stor future stair up collection sump-pit collection sump-pit future stair up stor KITHEN frig TH 60"x36" shower EDROOM w/d LIVING TV TV LIVING w/d EDROOM stor stor LOTS 8 & 9 GROUND FLOOR PLN W E T S K I W I N L E R T DTE 9 Jan a

13 UILDING LSSIFITION: PRT 3 - (891 sq m) GROUP F, DIVISION 2 UP TO 3 STOREYS ( ) MJOR OUPNY: LOW HZRD INDUSTRIL UILDING HEIGHT: ONE STOREY UILDING ESS: FING 2 STREETS FIRE PROTETION: UNSPRINKLERED EXISTING TXI WY 'E' NEW SPHLT TXI WY 'E' th STREET NORTH UILDING RE - 60'-0" x 80'-0" = 4,800 sq ft (445 sq m) ech unit TLE ONE STOREY FING 2 STREETS 1,500 sq m LLOWED MXIMUM OMUSTILE ONTENT LLOWED UNDER GROUP F DIVISION 3, NOT MORE THN 50 kg/sq.m. 50 kg = 16 gallons x 446 sq.m. = 4 kg/sq.m. MXIMUM LLOWED (as above ) IS 50 kg/sq.m. TLE MINIMUM ONSTRUTION REQUIREMENTS FOR LESS THN 1.5m SETK: 0-10% OPENINGS REQUIRE 1 HOUR RTING, NON OMUSTILE OTH SIDES TLE D LYERS 5/8" (15.9mm) TYPE X = 80 mins. (40 min x 2 = 80 mins) TLE D x 8 2'-0" O. (600mm) = 15 mins TLE D D OLUMN FILLED WITH PREFORMED INSULTION ONFORMING TO N/UL = 5 min TOTL INTERIOR WLL FE = 100 min (1 1/2 hrs) TLE D LYERS 5/8" TYPE X = 40 min TLE D x 8 2'-0" O. (600mm) = 15 mins TLE D D OLUMN FILLED WITH PREFORMED INSULTION ONFORMING TO N/UL = 5 min TOTL EXTERIOR WLL FE = 60 min (1 hr) OMINED TOTL = 160 MIN (2 1/2HRS) PROPOSED FIRE RTED SSEMLIES PRTY WLL - 2 layers 5/8" type X drywall each side of double 2x8 framed wall PRTY WLL IN TTI - 2 layers 5/8" type X drywall each side of 2x4 framed wall HNGR EILING - metal cladding (no rating) UPPER LEVEL EILING - 1 layer 5/8" type X drywall UPPER LEVEL FLOOR - Single layer 5/8" type X drywall to u/s of joists with supporting structure clad with 5/8" type X drywall EXTERIOR EST & WEST WLLS - 2X8 24" o.c. (as described above) W3 - NORTH WLL EXTERIOR WLL ONTRUTION 5/8" plywood R20 batt insulationl 6 mil poly V.. 2x6 framing 5/8" plywood metal cladding FIRE RTING LULTION EXTERIOR WLL LEL W1 INTERIOR NOTE See sheet 7 for shear panel;s & bracing W1 - EST & WEST EXTERIOR WLL ONSTRUTION From interior to exterior: metal interior liner, 2x4 24" o.c. 2 layers 5/8" type X drywall 2x8 16" o.c. insulation 1 layer 5/8" type X drywall 2 layers 15 lb felt 2x4 24" o.c. metal exterior liner. W2 - SOUTH WLL EXTERIOR WLL ONTRUTION 5/8" drywall R20 batt insulation 6 mil poly V.. 2x6 framing 1/2" plywood metal cladding and faux stone to bottom 36" RODWY LOTION PLN SITE PLN SLE 1:250 NORTH (not to scale) ON. DRIVEWY NEW ROD 17 46'-0" 136'-0" HNGR FINISHED FLOOR LLOW FOR 16" +- TOPSOIL REMOVL T HNGR PRONS ND SITE DRIVEWY PLN LOTS LOTIONS 14 & 15 NOTE DRINGE ETWEEN HNGRS FROM TXIWY TO ROD 1) MX GRDE 1% FROM HNGR TO TXIWY 2) MIN GRDE 2% FROM HNGR TO ROD HNGR - WETSKIWIN IRPORT 80'-0" HNGR ONE HNGR TWO FINISHED FLOOR '-0" DTE MY W E T S K I W I N L E R T 1 60'-0" 60'-0" ON. PRON 43'-0" ON. PRON MUNIIPL DDRESS 6104 & th VE WETSKIWIN 1/2% TXIWY LEGL DESRIPTION LOT S 8 & 9 LOK 5 PLN WETSKIWIN, LERT