1D - THREADED LIFTING SYSTEMS

Size: px
Start display at page:

Download "1D - THREADED LIFTING SYSTEMS"

Transcription

1 1D - THREADED LIFTING SYSTEMS Terwa reserves the right to make changes to the documentation at any time Page 1

2 OVERVIEW LIFTING SYSTEMS THL THS1 THS3-HD TIL Page 38 Page 40 Page 42 Page 46 LIFTING AND TRANSPORT ANCHORS TGK TGL TRL HBB HSB Page 17 Page 20 Page 21 Page 25 Page 31 HSB with stopper HSR HSP HBP Page 32 Page 33 Page 35 Page 37 FIXING ACCESSORIES SN KU-10 TPM KU-02 TBP Page 49 Page 50 Page 51 Page 51 Page 52 DATA CLIP PLASTIC PLUG TP-02 COVER SEALING CAP Page 52 Page 54 Page 55 Page 56 Terwa reserves the right to make changes to the documentation at any time Page 2

3 TABLE OF CONTENTS: OVERVIEW... 2 INTRODUCTION... 5 LIFTING SYSTEMS... 5 CE MARKING... 6 GENERAL GUIDANCE FOR LIFTING WITH TERWA THL, THS1 AND THS GENERAL GUIDANCE FOR CAST-IN WIRE LOOP SYSTEMS... 6 TECHNICAL INFORMATION CHOOSING THE TYPE OF ANCHOR... 7 SAFETY RULES... 7 ANCHORS LIFTING CONDITIONS... 8 ASYMMETRIC DISTRIBUTION OF THE LOAD... 8 LOAD CAPACITY... 9 WEIGHT OF PRECAST UNIT... 9 ADHESION TO FORMWORK COEFFICIENT... 9 DYNAMIC LOADS COEFFICIENT LIFTING AT AN ANGLE CABLE ANGLE COEFFICIENT LOAD DIRECTIONS POSITIONING THE ANCHORS IN WALLS DETERMINATION OF ANCHOR LOAD CALCULATION EXAMPLE EXAMPLE 1: SLAB UNIT EXAMPLE 2: WALL PANEL EXAMPLE 3: DOUBLE-T BEAM LIFTING SOCKET ANCHORS LIFTING SOCKET - WAVED END REINFORCING STEEL LIFTING SOCKET SHORT WAVED END REINFORCING STEEL TGK LIFTING AND TRANSPORT TGK ANCHORS LIFTING SOCKET LONG WAVED END REINFORCING STEEL TGL LIFTING SOCKET STRAIGHT END REINFORCING STEEL TRL LIFTING SOCKETS ANCHOR INSTALLATION AND REINFORCEMENTS REINFORCEMENT AND LOAD CAPACITY AXIAL LOAD UP TO REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD UP TO REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD AND TILTING UP TO LIFTING BOLT ANCHOR HBB LIFTING BOLT ANCHOR INSTALLATION AND REINFORCEMENTS REINFORCEMENT AND LOAD CAPACITY AXIAL LOAD UP TO REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD UP TO REINFORCEMENT AND LOAD CAPACITY TILTING UP TO REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD AND TILTING UP TO PLAIN LIFTING SOCKET AND LIFTING SOCKET WITH FLAT END PLAIN LIFTING SOCKET HSB PLAIN LIFTING SOCKET HSB-EV WITH STOPPER LIFTING SOCKET WITH FLAT END HSR LIFTING SOCKET WITH FOOT PLATE - HSP LIFTING BOLT ANCHOR HBP Terwa reserves the right to make changes to the documentation at any time Page 3

4 LIFTING SYSTEMS THREADED LIFTING LOOP - THL LIFTING SLING - THS THREADED SWIVEL EYE THS THS3 APPLICATIONS SPECIAL THREAD DESCRIPTION CAST-IN LIFTING LOOPS TIL ACCESSORIES DOUBLE METRIC MOUNTING PLUG SN PLASTIC NAILING PLATE KU PLASTIC NAILING PLATE KU STEEL MAGNETIC PLATE - TPM BREAKABLE FIXING PIN TBP DATA CLIP PLASTIC PLUG COVER SEALING CAP TP COVER SEALING CAP TP DISCLAIMER Terwa reserves the right to make changes to the documentation at any time Page 4

5 INTRODUCTION Thread-lifting systems are used in the precast industry and are suitable for lifting, transport and installation of precast concrete elements on site. Some of the advantages of this system are: - a wide range of lifting sockets - threaded lifting loops and cast-in lifting loops, - capability of establishing a connection in a safe, simple manner - most of the lifting systems can be re-used - CE conformance system. All Terwa lifting systems have the CE marking which guarantees conformance with the European regulations. The Threaded lifting system combines a lifting anchor embedded in a concrete unit and a lifting device. The design for Terwa threaded lifting anchors and technical instructions comply with the national German guideline VDI/BV- BS6205 Lifting inserts and lifting insert for precast concrete elements. Based on this guideline, the manufacturer must also ensure that the lifting systems have sufficient strength to prevent concrete failure. LIFTING SYSTEMS RE-USABLE LIFTING SYSTEM AND TRANSPORT ANCHORS - Anchor made from a socket swaged to wavy reinforcement steel. - Plain socket lifting inserts. - Socket welded to a plate. - Anchor made from a socket swaged to a standard screw for thin units. - A lifting loop manufactured from high grade steel wire swaged in a steel ferrule. - various accessories for recess forming or for affixing inserts to formwork CAST-IN LIFTING SYSTEM - Steel wire swaged forming a loop without additional tail. - Can be used with standard crane hook. - Cut off after use. CONNECTING ELEMENTS AND FIXING ACCESSORIES - Thread connections - Fixing Accessories Quality Terwa continuously controls the anchor production process from the perspective of strength, dimensional and material quality, and performs all of the required inspections for a superior quality system. All of the products are tracked from material acquisition to the final, ready to use product. Marking and traceability All anchors and lifting clutches have the CE marking and all data necessary for traceability, thread type and load class. Anchor testing Terwa lifting anchors are designed to resist at a minimum safety factor of 3x load group Terwa reserves the right to make changes to the documentation at any time Page 5

6 CE MARKING CE marking means that a product is manufactured and inspected in accordance with a harmonized European standard (hen) or a European Technical Approval (ETA). ETA can be used as the basis for CE marking for cases in which there is no hen. However, ETA is voluntary, not required by EU directives or legislation. Manufacturers may use the CE marking to declare that their construction products meet harmonized European standards or have been granted ETA Approvals. These documents define properties the products must have to be granted the right to use the CE marking and describe how the manufacture of these products is supervised and tested. EU s Construction Products Regulation takes full effect on 1 July There are no harmonized EN standards for detailed building parts such as connections used in concrete constructions, excluding lifting items and devices, which are covered by the EU Machinery Directive. For steel constructions, CE marking will become mandatory as of 1 July 2014 as covered by the EU Construction Products Directive. GENERAL GUIDANCE FOR LIFTING WITH TERWA THL, THS1 and THS3 Ensure that the concrete has Mpa strength of at least 15 before beginning lifting. The first choice for most lifting applications is the Lifting Socket with Waved rebar tail (TGK, TGL). For positioning the inserts, always check the permitted edge distances and spacing between inserts. We recommend restricting the lift angle to a maximum of 30 when an angled lift is necessary. To choose the proper lifting system, take how frequently the precast unit is going to be lifted into consideration. The cast-in threaded elements (anchors or fixing inserts) can be flush or recessed for corrosion protection. This recess is filled with fine concrete after use. All the Lifting Systems are tested before delivery under a test load three times the working load (individual test for THS1 and THS3, test for every batch of THL and TIL). THL THS1 THS3 GENERAL GUIDANCE FOR CAST-IN WIRE LOOP SYSTEMS Cast-in lifting loops TIL are used for lifting the precast concrete elements, especially beams. The lifting loop can easily be placed in the reinforcement cage of a precast unit. Part of the lifting system remains outside of the precast element for mounting the crane hook and lift. TIL Terwa reserves the right to make changes to the documentation at any time Page 6

7 TECHNICAL INFORMATION CHOOSING THE TYPE OF ANCHOR Terwa has 3 types of lifting systems: 1D Threaded lifting system 2D Strip anchor lifting system 3D T slot anchor lifting system The method of choosing the anchor is identical for all of these types and depends on the lifting method and/or experience. The 1D Threaded lifting system is mainly used when the hoisting angles are limited, while the 2D Strip anchor lifting system and the 3D T slot anchor lifting system can be used for all hoisting angles with minor limitations for the 2D Strip anchor lifting system. The difference between the 2D Strip anchor lifting system and the 3D T slot anchor lifting system is lies principally in the experience one has in using one or the other system. Terwa also has software for making the anchor calculations. SAFETY RULES The lifting system consists of a threaded anchor embedded in concrete and a threaded lifting device. The threaded lifting loop is connected to the anchor only when required for lifting. Ensure that the concrete has reached MPa strength of at least 15 before beginning lifting. These lifting systems are not suitable for intensive re-use. In designing the lifting system, it is essential to use the following safety factors to combat breakage: for steel component c = 3 for concrete element c = 2.5 for steel wires c = 4 The maximum permitted load on the components quoted in the tables has been obtained by applying a safety factor on test data. Terwa reserves the right to make changes to the documentation at any time Page 7

8 ANCHORS LIFTING CONDITIONS Using three anchors spaced the same distance apart from each other as in the figure, three load bearing anchors can be assumed. Load bearing anchors: n=3 Using four anchors lifted without a spreader beam, only two load bearing anchors can be assumed. Load bearing anchors: n=2 Perfect force distribution is assumed using a spreader beam. Load bearing anchors: n=4 Perfect static weight distribution can be obtained using a lifting beam and two pairs of anchors symmetrically placed. Load bearing anchors: n=4 The compensating lifting slings ensure equal force distribution. Load bearing anchors: n=4 When the element is lifted without a lifting table at a straight angle and contact with the ground is maintained. Additional shear reinforcement is required. When the element is lifted without a lifting table at an angle and contact with the ground is maintained. Additional shear reinforcement is required. ß 30 o ASYMMETRIC DISTRIBUTION OF THE LOAD For asymmetrical elements, calculate the loads based on the centre of gravity before installing the anchors. The load of each anchor depends on the embedded position of the anchor in the precast unit and on the transport mode: a) If the arrangement of the anchors is asymmetrical in relation to the centre of gravity, the individual anchors support different loads. For the load distribution in asymmetrically installed anchors when a spreader beam is used, the forces on each anchor is calculated using the following equation: Terwa reserves the right to make changes to the documentation at any time Page 8

9 F a = F tot b/(a + b) F b = F tot a/(a + b) Note: To avoid tilting the element during transport, the load should be suspended from the lifting beam in such a way that its centre of gravity (Cg) is directly under the crane hook. b) For transporting without a lifting beam, the load on the anchor depends on the cable angle (ß). LOAD CAPACITY The load capacity of the anchor depends on multiple factors such as: The deadweight of the precast concrete element G Adhesion to the formwork The load direction, angle of pull. Number of load bearing anchors The edge distance and spacing of the anchors The strength of the concrete when operating, lifting or transporting The embedded depth of the anchor Dynamic forces The reinforcement arrangement WEIGHT OF PRECAST UNIT The total weight G of the precast reinforced concrete element is determined using a specific weight of: ρ = 25kN/m³. For prefabricated elements composed of a higher concentration of reinforcing elements, this will be taken into consideration in calculating the weight. G = ρ V V = L l s where: V - volume of precast unit in [m³] L length in [m] l width in [m] s thickness in [m] ADHESION TO FORMWORK COEFFICIENT When a precast element is lifted from the formwork, adhesion force between element and formwork develops. this force must be taken into consideration for calculation of the anchor load and depends on the total area in contact with the formwork, the shape of the precast element and the material of the formwork. The value H a of adhesion to the formwork is calculated using the following equation: H a = q A [kn] where: q- the adhesion to formwork factor corresponding to the material of the formwork A - the area of contact between the formwork and the concrete element when starting the lift Terwa reserves the right to make changes to the documentation at any time Page 9

10 Adhesion to the formwork oiled steel formwork q 1 kn/m 2 varnished timber formwork q 2 kn/m 2 oiled rough timber formwork q 3 kn/m 2 In some cases, such as π - panel or other specially shaped elements, an increased adhesion coefficient must be taken into consideration. Adhesion to the formwork Double T beam Ribbed elements Waffled panel where: G - dead weight of the element. H a = 2 G [kn] H a = 3 G [kn] H a = 4 G [kn] Adhesion to the formwork should be minimized before lifting the concrete element out of the formwork by removing as many parts of the formwork as possible. Before lifting from the table, the adhesion to the formwork must be reduced as much as possible by removing the formwork from the concrete element (tilting the formwork table, brief vibration for detachment, using wedges). DYNAMIC LOADS COEFFICIENT When movement of the precast units is performed using lifting gear, dynamic forces which depend on the lifting gear used develop. The lifting classes are described in DIN Lifting class Lifting load coefficient f at lifting speed vh Up to 90 m/min Over 90 m/min H vh 1.3 H vh 1.6 H vh 1.9 H vh 2.2 Lifting equipment Dynamic coefficient f Rail crane, swing-boom crane and fixed crane 1.3 *) Lifting and transporting on level terrain 2.5 Lifting and transporting on uneven terrain 4.0 *) lower values may be appropriate in precast plants if special arrangements are made. For cranes with precision lifting such as those in manufacturing plants, the lifting load coefficient is f = IN THE PRECAST YARD: - for lifting out of the formwork f = for tilt-up and transport f = 1.3 Terwa reserves the right to make changes to the documentation at any time Page 10

11 ON SITE: - for tilt-up/transport/install f = when transporting suspended precast elements over uneven terrain, the lifting load coefficient used is f > 2. For special transport and lifting cases, the dynamic coefficient is established based on the tests or on proven experience. LIFTING AT AN ANGLE CABLE ANGLE COEFFICIENT The load value applied on each anchor depends on the chain inclination, which is defined by the angle β between the normal direction and the lifting chain. The cable angle β is determined by the length of the suspension chain. We recommend that, if possible, β should be kept to β 30 o. The tensile force on the anchor will be increased by a cable angle coefficient z. F = F tot z/n where: z - cable angle coefficient n - number of load bearing anchors Cable angle Spread angle Cable angle factor β a z * * * preferred ß 30 Note: If no lifting beam is used during transport, the anchor must be embedded symmetrical to the load. Lifting symbols used in the documentation Axial pull in direction of anchor axis. Transversal pull perpendicular to the anchor axis. Angled pull, lifting at an angle to the anchor axis Terwa reserves the right to make changes to the documentation at any time Page 11

12 LOAD DIRECTIONS Various scenarios can occur during transport and lifting such as tilt-up, rotation, hoisting and, of course, installation. The lifting anchors and clutches must have the capacity for all these cases and combinations of them. Therefore, the load direction is a very important factor for proper anchor selection. Axial load ß = 0 o to 10 o Diagonal load ß = 10 o to 45 o Note: ß 30 o is recommended Tilting g = 90 o Additional shear reinforcement steel must be used. When a tilting table is used, the anchors can be used without additional shear reinforcement steel, not to exceed the angle g < 15 o POSITIONING THE ANCHORS IN WALLS Load bearing anchors: n=2 Load bearing anchors: n=4 Load bearing anchors: n=4 Terwa reserves the right to make changes to the documentation at any time Page 12

13 Lifting the walls from horizontal to vertical position without tilt-up table. In this case, the anchors are loaded with half of the element weight since half of the element remains in contact with the casting table. DETERMINATION OF ANCHOR LOAD The load on each load bearing anchor is calculated using the following formula: - When de-mouldf = (F tot f z)/n = [(G + H a ) f z]/n - When tiltingf = (F tot /2 f z)/n = [(G/2 + H a ) f z]/n During tilting, when the concrete element remains supported on the ground, only half of the forces have to be taken into account. For tilting, the load-bearing capacity of sockets and anchors is limited to 50% of the axial load. - When lifting F = (F tot f z)/n = (G f z)/n INSTALLATION TOLERANCES FOR ALL TERWA LIFTING SOCKET ANCHORS Terwa reserves the right to make changes to the documentation at any time Page 13

14 CALCULATION EXAMPLE Example 1: SLAB UNIT The slab unit has the following dimensions: L = 5 m, l = 2 m, s = 0. 2 m Weight G = ρ V = 25 ( ) = 50 kn Formwork area A = L l = 5 2 = 10 m 2 Anchor number n = 2 General data: Symbol De-mould Transport Mount Concrete strength at de-mould [MPa] Concrete strength on site [MPa] 35 Element weight [kn] G 50 Element area in contact with formwork [m²] A 10 Cable angle factor at de-mould (β = 15.0 ) z Cable angle factor on site (β = 30.0 ) z 1.16 Dynamic coefficient at de-mould f 1.1 Dynamic coefficient at transport f 1.3 Dynamic coefficient on site f 1.5 Adhesion to formwork factor for varnished timber formwork [kn/m²] q 2 Anchor number for de-mould n 2 Anchor number for transport at the plant n 2 Anchor number for transport on site n 2 DE-MOULD AT THE PLANT: F = Adhesion to formwork factor: q = 2 kn/m 2 Lifting load coefficient: f = 1.1 Cable angle factor: z = 1.04 (β = 15.0 ) Concrete strength: 15 MPa [(G + q A) f z] = n TRANSPORT AT THE PLANT: F = [( ) ] = kn 2 Dynamic coefficient: f = 1.3 Cable angle factor: z = 1.04 (β = 15.0 ) Concrete strength: 15 MPa G f z n TRANSPORT AT SITE: F = = = kn 2 Dynamic coefficient: f = 1.5 Cable angle factor: z = 1.16 (β = 30.0 ) Concrete strength: 35 MPa G f z n = = kn 2 An anchor in the 50 kn range is required. Terwa reserves the right to make changes to the documentation at any time Page 14

15 Example 2: WALL PANEL The slab unit has the following dimensions: L = 7. 5 m, l = 2 m, s = m Weight G = ρ V = 25 ( ) = kn Formwork area A = L l = = 15 m 2 Anchor number n = 2 General data: Symbol De-mould Tilting Mount Concrete strength at de-mould [MPa] Concrete strength on site [MPa] 45 Element weight [kn] G 67.5 Element area in contact with formwork [m²] A 15 Cable angle factor at de-mould (β = 0,0 ) z 1.0 Cable angle factor at tilting (β = 0.0 ) z 1.0 Cable angle factor on site (β = 30 ) z 1.16 Dynamic coefficient at de-mould f 1.1 Dynamic coefficient at tilting f 1.3 Dynamic coefficient on site f 1.3 Adhesion factor for oiled steel formwork [kn/m²] q 1.0 Anchor number for de-mould n 4 Anchor number at tilting n 2 Anchor number for transport on site n 2 DE-MOULD / TILT-UP AT THE PLANT: F = Adhesion to formwork factor: q = 1 kn/m 2 Lifting load coefficient: f = 1.1 Cable angle factor: z = 1 (β = 0 ) Concrete strength: 15 MPa [(G/2 + q A) f z] = n TRANSPORT AT THE PLANT: F = [(67. 5/ ) ] = kn 2 Dynamic coefficient: f = 1.3 Cable angle factor: z = 1 (β = 0 ) Concrete strength: 15 MPa G f z n TRANSPORT ON SITE: F = = = kn 2 Dynamic coefficient: f = 1.3 Cable angle factor: z = 1.16 (β = 30.0 ) Concrete strength: 35 MPa G f z n = = kn 2 For embedding on lateral side, two anchors in the 63kN range are required. Tail and tilting reinforcement are usually added for this type of anchor reinforcement. De-formwork before tilting is recommended. Terwa reserves the right to make changes to the documentation at any time Page 15

16 Example 3: DOUBLE-T BEAM NOTE: Dimensions are in cm General data: Symbol De-mould Transport Concrete strength at de-mould and transport [MPa] Element weight [kn] G 102 Formwork area [m²] A 35.8 Cable angle factor at de-mould (ß = 30.0 ) z 1.16 Cable angle factor on site (ß = 30.0 ) z 1.16 Lifting load coefficient at de-mould f 1.0 Lifting load coefficient at transport f 1.3 Anchor number for de-mould and transport n 4 4 Load capacity when lifting and transporting at the manufacturing plant. Concrete strength when de-mould 25 MPa Cable angle factor z = 1.16 (ß = 30.0 ) Lifting load coefficient when transporting f = 1.3 Lifting load coefficient when de-mould f = 1.0 Anchor number n = 4 G = V x ρ = (A x L)x ρ = (A1 + A2 x 2) x L x ρ = (0.1 x x 2) x 8.5 x 25 = 102 kn L = 8.5 m A1 = 0.1 x 3 (m²) A2 = [( ) x 30] /2 (cm²) A2 = [( )x 0.3 /2 = (0.6 x 0.3)/2 = 0.09 (m²) Weight: Adhesion to mould Total load G = 102 kn Ha = 2 x G = 204 kn F to =G + Ha = = 306 kn LOAD PER ANCHOR WHEN DE-MOULD: F = Ftot x f x z = n [(G + Ha)x f x z] 306 x 1. 0 x = = kn n 4 LOAD PER ANCHOR WHEN TRANSPORTING: F = Ftot x f x z = n G x f x z 102 x 1. 3 x = = kn n 4 An anchor in the 100 kn range is required (> kn) Terwa reserves the right to make changes to the documentation at any time Page 16

17 LIFTING SOCKET ANCHORS LIFTING SOCKET - WAVED END REINFORCING STEEL Waved lifting sockets are used for lifting moderately thick precast elements. The waved shape provides good force transfer into the concrete. These lifting sockets consist of a steel bush made of S355, stainless steel SS2 or SS4, swaged to a wavy reinforcing bar. The threaded bushes are made with metric thread (M) or round thread (Rd) zinc plated. These lifting sockets are always the preferred option. They ensure the necessary length and edge distance. The preferred lift angle is ß 30. LIFTING SOCKET SHORT WAVED END REINFORCING STEEL TGK TGK-M Product number Load group f cu > 15 MPa Thread Bar diam. Overall length L l 1 Zinc Stainless steel Stainless steel galvanizing SS4 SS2 [t] M [mm] [mm] [mm] TGK-M TGK-M TGK-M TGK-M TGK-M TGK-M TGK-M TGK-Rd Product number Load group f cu > 15 MPa Thread Bar diam. Overall length L l 1 Zinc Stainless steel Stainless steel galvanizing SS4 SS2 [t] Rd [mm] [mm] [mm] TGK-Rd TGK-Rd TGK-Rd TGK-Rd TGK-Rd TGK-Rd TGK-Rd TGK-Rd TGK-Rd TGK-Rd Terwa reserves the right to make changes to the documentation at any time Page 17

18 LIFTING AND TRANSPORT TGK ANCHORS Edge distance and spacing for lifting sockets. TGK-M(Rd) s minimum a minimum b minimum [mm] [mm] [mm] M(Rd) M(Rd) M(Rd) M(Rd) M(Rd) M(Rd) M(Rd) The TGK anchors are used for lifting flat elements such as floor slabs. The lifting angle must be 45. For a lifting angle between 10 and 45, additional reinforcement is required. TGK-M(Rd) Load group Thread Overall length Element thickness f cu> 15 MPa Axial load and diagonal load MPa [t] M(Rd) [mm] [mm] [kn] TGK-M(Rd) TGK-M(Rd) TGK-M(Rd) TGK-M(Rd) TGK-M(Rd) TGK -M(Rd) TGK -M(Rd) Diagonal reinforcement TGK-M(Rd) short Thread Two layers of mesh Diameter d Length before bending Ls 15 MPa MRd mm²/m [mm] [mm] TGK M(Rd) x 188 Ø TGK M(Rd) x 188 Ø TGK M(Rd) x 188 Ø TGK M(Rd) x 188 Ø TGK M(Rd) x 188 Ø TGK -M(Rd) x 188 Ø Note: The bend radius will be determined according to EN There must be two layers of mesh reinforcement. Diagonal reinforcement must be placed in direct contact with the socket anchor. Always install diagonal reinforcement opposite the load direction. TGK -M(Rd) x 188 Ø Terwa reserves the right to make changes to the documentation at any time Page 18

19 Note: The bend radius will be determined according to EN Diagonal reinforcement must be placed in direct contact with the socket anchor. Always install diagonal reinforcement opposite the load direction. The dimensions in the illustrations are in [mm]. Terwa reserves the right to make changes to the documentation at any time Page 19

20 LIFTING SOCKET LONG WAVED END REINFORCING STEEL TGL Long waved lifting sockets are used for lifting all types of precast concrete elements, especially for erecting thin panels. They are also well-suited for lifting thin, low-grade reinforcement panels. TGL-M Product number Load group f cu > 15 MPa Thread Bar diam. Overall length L l 1 Zinc galvanizing Stainless steel SS4 Stainless steel SS2 [t] M [mm] [mm] [mm] TGL-M TGL-M TGL-M TGL-M TGL-M TGL-M TGL-M TGL-M TGL-Rd Product number Load group f cu > 15 MPa Thread Bar diam. Overall length L l 1 Zinc galvanizing Stainless steel SS4 Stainless steel SS2 [t] Rd [mm] [mm] [mm] TGL-Rd TGL-Rd TGL-Rd TGL-Rd TGL-Rd TGL-Rd TGL-Rd TGL-Rd TGL-Rd Terwa reserves the right to make changes to the documentation at any time Page 20

21 LIFTING SOCKET STRAIGHT END REINFORCING STEEL TRL The TRL anchors are especially suitable for lifting thin concrete panels. There are two versions of Lifting Sockets with straight ends, with metric thread (M) or with round thread (Rd). The threaded socket is made of steel S355JO, zinc plated, or stainless steel and a reinforcing bar made of B500B with no coating. TRL-M Product number Load group f cu > 15N/mm² Thread Bar diam. Overall length L l 1 Zinc galvanizing Stainless steel SS4 Stainless steel SS2 [t] M [mm] [mm] [mm] TRL-M TRL-M TRL-M TRL-M TRL-M TRL-M TRL-M TRL-Rd Product number Load group f cu > 15N/mm² Thread Bar diam. Overall length L l 1 Zinc galvanizing Stainless steel SS4 Stainless steel SS2 [t] Rd [mm] [mm] [mm] TRL-Rd TRL-Rd TRL-Rd TRL-Rd TRL-Rd TRL-Rd TRL-Rd Terwa reserves the right to make changes to the documentation at any time Page 21

22 LIFTING SOCKETS ANCHOR INSTALLATION AND REINFORCEMENTS REINFORCEMENT AND LOAD CAPACITY AXIAL LOAD UP TO 10 TRL-M(Rd) Load group Minimum unit thickness Minimum axial spacing Mesh reinforcement Edge reinforcement Load capacity 2 x b a d s1 f cu > 15N/mm² f cu >25N/mm² [t] [mm] [mm] [mm 2 /m] [mm] [kn] [kn] M(Rd) x 188 Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø Terwa reserves the right to make changes to the documentation at any time Page 22

23 REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD UP TO 45 TRL-M(Rd) Load group Minimum unit thickness Minimum axial spacing Mesh reinforcement Edge reinforcement Diagonal reinforcement β > 30 max. 45 Load capacity for lifting loop application Load capacity for lifting THS application 2 x b a d s1 d s L s f cu > 15N/mm² f cu >25N/m m² f cu >25N/mm² [t] [mm] [mm] [mm 2 /m] [mm] [mm] [mm] [kn] [kn] [kn] M(Rd) x 188 Ø8 Ø M(Rd) x x Ø8 Ø M(Rd) x x Ø10 Ø M(Rd) x x Ø10 Ø M(Rd) x x Ø12 Ø M(Rd) x x Ø12 Ø M(Rd) x x Ø14 Ø Note: The bend radius for item 3 will be determined according EN Diagonal reinforcement must be placed in direct contact with the socket anchor. Always install diagonal reinforcement opposite the load direction. The dimensions in the illustrations are in [mm]. Terwa reserves the right to make changes to the documentation at any time Page 23

24 REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD AND TILTING UP TO 90 Note: The bend radius will be determined according to EN Only a long socket anchor may be used for tilting operations. The turning reinforcement must be placed in direct contact with the socket anchor. The dimensions in the illustrations are in [mm]. Do not use lifting loop for tilting. TRL-M(Rd) Load group Minimum unit thickness 2 x b Mesh reinforcement Edge reinforcement Turning reinforcement Lateral reinforcement d s1 d s2 L H R d s3 l Load capacity f cu > 15N/mm² f cu >25N/ mm² [t] [mm] [mm 2 /m] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kn] [kn] M(Rd) x 188 Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø Terwa reserves the right to make changes to the documentation at any time Page 24

25 LIFTING BOLT ANCHOR HBB The Lifting Bolt anchors are suitable for shallow embedded elements with no need for a reinforcement tail. The force transfer into the concrete is provided by the bolt heat of the screw. Additional reinforcement is necessary for angled lifts. The lift angle must not exceed 30. Special tilting reinforcement must be used for turning/tilting. In all cases, Standard mesh reinforcement must be present in the concrete element. These fixing and lifting systems consist of a threaded bush locked on a standard bolt. The threaded bush is made of steel S355JO (yield strength min 355 MPa) galvanic protected (EV) or hot dipped galvanized (TV); the bolt is made of steel group 8.8. The threaded bush can also be made of stainless steel W AISI 316Ti (SS4). HBB Product number Load group f cu > 15N/mm² Thread Overall length L l 1 Bolt Zinc galvanizing Stainless steel SS4 Hot dipped galvanized [t] M [mm] [mm] HBB M12x M12x60 HBB M12x M12x70 HBB M12x M12x120 HBB M16x M16x100 HBB M16x M16x180 HBB M20x M20x90 HBB M20x M20x100 HBB M20x M20x130 HBB M20x M20x220 HBB M24x M24x140 HBB M24x M24x260 HBB M30x M30x160 HBB M30x M30x300 HBB M36x M36x200 HBB M36x M36x320 HBB M42x M42x200 HBB M42x M42x360 Terwa reserves the right to make changes to the documentation at any time Page 25

26 HBB Product number Load group f cu > 15N/mm² Thread Overall length L l 1 Bolt Zinc galvanizing Stainless steel SS4 Hot dipped galvanized [t] Rd [mm] [mm] HBB Rd12x M12x60 HBB Rd12x M12x70 HBB Rd12x M12x120 HBB Rd16x M16x100 HBB Rd16x M16x180 HBB Rd20x M20x90 HBB Rd20x M20x130 HBB Rd20x M20x220 HBB Rd24x M24x140 HBB Rd24x M24x260 HBB Rd30x M30x160 HBB Rd30x M30x300 HBB Rd36x M36x200 HBB Rd36x M36x320 HBB Rd42x M42x200 HBB Rd42x M42x360 Terwa reserves the right to make changes to the documentation at any time Page 26

27 LIFTING BOLT ANCHOR INSTALLATION AND REINFORCEMENTS REINFORCEMENT AND LOAD CAPACITY AXIAL LOAD UP TO 10 HBB-M(Rd) Load group Minimum unit thickness Axial spacing Mesh reinforcement Edge reinforcement Load capacity 2 x b a d s1 f cu > 15N/mm² f cu >25N/mm² [t] [mm] [mm] [mm 2 /m] [mm] [kn] [kn] M(Rd) x 188 Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø Terwa reserves the right to make changes to the documentation at any time Page 27

28 REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD UP TO 45 HBB-M(Rd) Load group Minimum unit thickness Axial spacing Mesh reinforcement Edge reinforcement Diagonal reinforcement β > 30 max. 45 Load capacity for lifting loop application Load capacity for lifting THS application 2 x b a d s1 d s L s f cu > 15N/mm² f cu >25N/m m² f cu >25N/mm² [t] [mm] [mm] [mm 2 /m] [mm] [mm] [mm] [kn] [kn] [kn] M(Rd) x 188 Ø8 Ø M(Rd) x x Ø8 Ø M(Rd) x x Ø10 Ø M(Rd) x x Ø10 Ø M(Rd) x x Ø12 Ø M(Rd) x x Ø12 Ø M(Rd) x x Ø14 Ø Note: The bend radius will be determined according to EN Diagonal reinforcement must be placed in direct contact with the socket anchor. Always install diagonal reinforcement opposite the load direction. The dimensions in the illustrations are in [mm]. Terwa reserves the right to make changes to the documentation at any time Page 28

29 REINFORCEMENT AND LOAD CAPACITY TILTING UP TO 90 Note: The bend radius will be determined according to EN Only a long socket anchor may be used for tilting operations. The turning reinforcement must be placed in direct contact with the socket anchor. The dimensions in the illustrations are in [mm]. Do not use lifting loop for tilting. HBB-M(Rd) Load group Minimum unit thickness 2 x b Edge Mesh reinforcement reinforcement Turning reinforcement Lateral reinforcement d s1 d s2 L H R d s3 l Load capacity f cu > 15N/mm² f cu >25N/ mm² [t] [mm] [mm 2 /m] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kn] [kn] M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø M(Rd) x x Ø Terwa reserves the right to make changes to the documentation at any time Page 29

30 REINFORCEMENT AND LOAD CAPACITY DIAGONAL LOAD AND TILTING UP TO 90 For tilting and diagonal pull, additional reinforcements must be installed in the anchor zone. Make certain that the placement of the anchors ensures load transfer. When turning and lifting at an angle, tilt reinforcement is sufficient and there is no need for angle lift reinforcement. We recommend that, if possible, angle ß not exceed 30. Tilt reinforcement TGK/ TGL/ TRL/HBB - M(Rd) Tilt reinforcement Ød 3 L h [mm] [mm] [mm] M(Rd) M(Rd) M(Rd) M(Rd) M(Rd) M(Rd) M(Rd) Terwa reserves the right to make changes to the documentation at any time Page 30

31 PLAIN LIFTING SOCKET AND LIFTING SOCKET WITH FLAT END The Plain Lifting Sockets and the Lifting Sockets with Flat End are economical solutions and are suitable for thin concrete elements, where the long tail provides excellent anchorage. The reinforcement tail is important and must be installed as shown in the following illustrations. The Plain Lifting Sockets are made of steel S355JO zinc plated or of stainless steel AISI 316Ti (SS4); the Lifting Sockets with Flat End are made of steel tube S355JO galvanized. These sockets are designated for lifting and are not to be confused with fixing sockets. The safe working loads shown are after the application of a safety factor on test loads: c=2 for 15 MPa concrete and c=3 for steel. These anchors are not designed for tilting. PLAIN LIFTING SOCKET HSB These are plain lifting sockets made of a round bar of steel S355JO galvanized or stainless steel (W ), with no plastic stopper. HSB-M Product number Thread Load group f cu > 15 MPa Overall length L D l 1 d Zinc Stainless steel galvanizing SS4 M [t] [mm] [mm] [mm] [mm] HSB-M12x HSB-M16x HSB-M20x HSB-M24x HSB-M30x HSB-M36x HSB-M42x HSB-M52x HSB-Rd Product number Thread Load group f cu > 15 MPa Overall Length L D l 1 d Zinc Stainless steel galvanizing SS4 Rd [t] [mm] [mm] [mm] [mm] HSB-Rd12x HSB-Rd16x HSB-Rd20x HSB-Rd24x HSB-Rd30x HSB-Rd36x HSB-Rd42x HSB-Rd52x Terwa reserves the right to make changes to the documentation at any time Page 31

32 PLAIN LIFTING SOCKET HSB-EV WITH STOPPER This is a plain lifting socket made of a round tube of steel S355JO galvanized with a plastic stopper inside made of polyethylene LDPE 035 to stop wet concrete from getting in the thread zone. HSB-M Product no. Thread Load group f cu > 15 MPa Overall Length L D l 1 d Zinc galvanizing M [t] [mm] [mm] [mm] [mm] HSB-M12x HSB-M16x HSB-M20x HSB-M24x HSB-M30x HSB-M36x HSB-M42x HSB-M52x HSB-Rd Product no. Thread Load group f cu > 15 MPa Overall Length L D l 1 d Zinc galvanizing Rd [t] [mm] [mm] [mm] [mm] HSB-Rd12x HSB-Rd16x HSB-Rd20x HSB-Rd24x HSB-Rd30x HSB-Rd36x HSB-Rd42x HSB-Rd52x Terwa reserves the right to make changes to the documentation at any time Page 32

33 LIFTING SOCKET WITH FLAT END HSR The Lifting Sockets with Flat End are made of steel tube S355JO galvanized or stainless steel. HSR-M Product number Thread Load group f cu > 15 MPa Overall Length L D l 1 d Zinc galvanizing Stainless steel SS4 M [t] [mm] [mm] [mm] [mm] HSR-M12x HSR-M16x HSR-M20x HSR-M24x HSR-M30x HSR-M30x HSR-Rd Product number Thread Load group f cu > 15 MPa Overall Length L D l 1 d Zinc galvanizing Stainless steel SS4 Rd [t] [mm] [mm] [mm] [mm] HSR-Rd12x HSR-Rd16x HSR-Rd20x HSR-Rd24x HSR-Rd30x HSR-Rd30x Terwa reserves the right to make changes to the documentation at any time Page 33

34 PLAIN LIFTING SOCKETS INSTALLATION AND REINFORCEMENTS LIFTING AND TRANSPORT The details on this page are applicable for panels, but they could equally apply to other components. Edge distance and spacing of plain lifting sockets and lifting socket with flat end. Angled pull reinforcement Anchorage reinforcement Note: The bend radius will be determined according to EN The anchorage reinforcement must be in full contact with the bottom edge of the hole. Reducing the rebar length is permitted; the ends of rebar must be bent into hooks. The dimensions in the illustrations are in [mm]. M / Rd Minimum unit thickness Axial spacing 2 x b a Mesh reinforcement Axial load ß 10 Load capacity f cu> 15MPa Load capacity f cu> 15MPa Diagonal load 10 ß 30 Angled pull reinforcement Ø x l s Load capacity f cu> 15MPa Diagonal load 10 ß 45 Angled pull reinforcement Ø x l s Anchorage reinforcement Length before d bending La [mm] [mm] [mm 2 /m] [kn] [kn] [mm] [kn] [mm] [mm] [mm] Ø 6 x Ø 6 x Ø 6 x Ø 8 x Ø 8 x Ø 8 x Ø 8 x Ø 10 x Ø 10 x Ø 12 x Ø 12 x Ø 14 x Ø 14 x Ø 16 x Ø 16 x Ø 20 x The information presented in these pages is also applicable for Lifting Sockets with Flat End HSR. Terwa reserves the right to make changes to the documentation at any time Page 34

35 LIFTING SOCKET WITH FOOT PLATE - HSP The low profile Lifting Socket with Footplate is suitable for the face of thin panels or top slabs, which are lifted perpendicular to their largest surface. The footplate and the socket are fully welded, so the insert is effectively sealed. The threaded bush is made of steel S355JO, and the plate is made of steel sheet S235JR. They are zinc plated. These products can be made of stainless steel SS2 (W ) or SS4 (W ). The preferred lift angle is ß 30. The safe working loads presented are after the application of a safety factor on test loads of 2 for 15MPa concrete and 3 for steel. HSP-M Product no. Thread Load group f cu > 15 MPa Overall length L a b Zinc galvanizing Stainless steel SS4 Stainless steel SS2 M [t] [mm] [mm] [mm] HSP-M HSP-M HSP-M HSP-M HSP-M HSP-M HSP-M HSP-M HSP-Rd Product no. Thread Load group f cu > 15 MPa Overall length L a b Zinc galvanizing Stainless steel SS4 Stainless steel SS2 Rd [t] [mm] [mm] [mm] HSP-Rd HSP-Rd HSP-Rd HSP-Rd HSP-Rd HSP-Rd HSP-Rd HSP-Rd Terwa reserves the right to make changes to the documentation at any time Page 35

36 LIFTING SOCKETS HSP INSTALLATION AND REINFORCEMENTS HSP M(Rd) Load group Minimum unit thickness Anchor spacing Edge distance Smin a b Mesh reinforcement [t] [mm] [mm] [mm] [mm 2 /m] Note: The bend radius will be determined according to EN Additional reinforcement must be placed and secured on top of the plate anchor and in direct contact with the plate For anchors with thread larger than M24, additional reinforcement must be placed cross-wise in pairs. The dimensions in the illustrations are in [mm]. HSP M(Rd) Additional reinforcement number d s L 1 L 2 h L Axial load ß 10 Load capacity f cu> 15MPa Load capacity f cu> 15MPa Diagonal load 10 ß 30 Diagonal load 30 ß 45 Angled pull Load capacity reinforcement f Ø x l cu> 15MPa s Angled pull reinforcement Ø x l s [pcs] [mm] [mm] [mm] [mm] [mm] [kn] [kn] [mm] [kn] [mm] Ø 6 x Ø 6 x Ø 6 x Ø 8 x Ø 8 x Ø 8 x Ø 8 x Ø 10 x Ø 10 x Ø 12 x Ø 12 x Ø 14 x Ø 14 x Ø 16 x Ø 16 x Ø 20 x 1600 Terwa reserves the right to make changes to the documentation at any time Page 36

37 LIFTING BOLT ANCHOR HBP The Lifting Bolt anchor HBP is made of a threaded bush locked on a standard bolt and an anchorage plate. The threaded bush is made of steel S355JO, electrolytic galvanized (EV) or hot dipped galvanized (TV); the bolt is made of steel 8.8 with no coating; and the plate is made of steel S235, also with no coating. The threaded bush can also be made of stainless steel W AISI 316Ti (SS4). HBP-M Product no. Thread Load group f cu > 15 MPa Overall length L l 1 a b Screw Zinc galvanizing Stainless steel SS4 Hot dipped galvanized M [t] [mm] [mm] [mm] [mm] HBP M12x M12x25 HBP M16x M16x35 HBP M20x M20x40 HBP M24x M24x50 HBP M30x M30x60 HBP-Rd Product no. Thread Load group f cu > 15 MPa Overall length L l 1 a b Screw Zinc galvanizing Stainless steel SS4 Hot dipped galvanized Rd [t] [mm] [mm] [mm] [mm] HBP Rd12x M12x25 HBP Rd16x M16x35 HBP Rd20x M20x40 HBP Rd24x M24x50 HBP Rd30x M30x60 Terwa reserves the right to make changes to the documentation at any time Page 37

38 LIFTING SYSTEMS THREADED LIFTING LOOP - THL Threaded lifting loops are suitable for use with all sizes of threaded lifting sockets. It is an economical lifting system that can be used for most applications, especially for onsite operations. Threaded lifting loops are not suitable for turning or tilting. If the loops are kept in storage for reuse, they must be inspected every six months and retested every year. These lifting systems are not recommended for intensive reuse conditions. Threaded lifting loops should only be attached to the concrete unit and used after the concrete strength has reached 15 MPa. In some cases, it may be economical and practical to leave this lifting loop with the concrete unit for final installation. The threaded lifting loop is made of high grade steel wire AISI 1010 (W ), swaged in a steel ferrule made of steel S355JO. It is zinc-plated for protection against corrosion. A label marked with the admissible load, the thread type and the code number of the testing is attached to each threaded lifting loop. Before use, check that the wires are in good condition. Do not use if the wire cable is bent, crushed or kinked or if there is any loosening of the outer layer. Discard if the wire is corroded or the thread is damaged. THL-M Load Wire L Thread Thread l group 1 l diam. (approx.) Product no. THL-Rd Product no. M Rd [t] [mm] [mm] [mm] [mm] THL-M THL-Rd THL-M THL-Rd THL-M THL-Rd THL-M THL-Rd THL-M THL-Rd THL-M THL-Rd THL-M THL-Rd THL-M THL-Rd Terwa reserves the right to make changes to the documentation at any time Page 38

39 THL APPLICATIONS SCREWING DETAILS Ensure that the thread is fully bottomed out in the socket before lifting. Backing off one turn is permitted to ensure that the wire is correctly aligned for lifting. Any gap between the concrete element and the body of the lifting system is not permitted: the thread must be fully threaded inside the socket. ADMISSIBLE LOAD DIRECTION Threaded lifting loops are not suitable for turning or tilting. Terwa reserves the right to make changes to the documentation at any time Page 39

40 LIFTING SLING - THS1 The Lifting Slings can be used with all types of anchors and threaded sockets. They are suitable for most lifting situations, particularly site operations. They can be reused, but only after inspection. If kept in storage for reuse, they must be inspected every six months and retested every year. These lifting systems are not recommended for intensive reuse conditions. The Threaded Lifting Sling should only be attached to the concrete unit and only used after the concrete strength has reached 15MPa. THS1-M Product no. Load Wire Thread Product Thread Axial load L d l THS1-Rd group 1 length no. M Rd [t] [kn] [mm] [mm] [mm] [mm] THS1-M THS1-Rd THS1-M THS1-Rd THS1-M THS1-Rd THS1-M THS1-Rd THS1-M THS1-Rd THS1-M THS1-Rd THS1-M THS1-Rd THS1-M THS1-Rd The Threaded Lifting Sling is made of high grade steel wire AISI 1010 (W ), swaged in a ferrule made of AlMg1.8 and a steel bolt made of high-strength steel. It is zinc-plated for protection against corrosion. Every Lifting System is individually tested at 3 times the working load and comes with its own unique certificate. Each threaded lifting loop has a label marked with the admissible load, the thread type and the code number of the testing. Before use you must check that the wires are in good condition. Do not use if the wire cable is bent, crushed or kinked or if there is any loosening of the outer layer. Discard if the wire is corroded. Ensure that the thread is fully bottomed out in the socket before lifting. Backing off one turn is permitted to ensure that the wire is correctly aligned for lifting. Optimum load transfer is ensured if the eye bolt is oriented in load direction. Diagonal or shear load is not permitted in this case. Terwa reserves the right to make changes to the documentation at any time Page 40

41 THS1 APPLICATIONS SCREWING DETAILS Ensure that the thread is fully bottomed out in the socket before lifting. Backing off one turn is permitted to ensure that the wire is correctly aligned for lifting. Any gap between the concrete element and the body of the lifting system is not permitted: the thread must be fully threaded inside the socket. The preferred option is the vertical lift. Normally the angle of lift (ß) should not be greater than 30. Pulling back towards the unit is not permitted. ADMISSIBLE LOAD DIRECTION Note: Minimum radius of the crane hook for the wire loop must be R > 1.5 x d Terwa reserves the right to make changes to the documentation at any time Page 41

42 THREADED SWIVEL EYE THS3 The Threaded Swivel Eye can be used for anchors with threaded sockets and are suitable for most lifting situations, particularly for turning and tilting. They are more suitable for turning and tilting than the lifting systems manufactured from steel wire and can, of course, be reused provided they are inspected regularly. If kept in storage for reuse, they must be inspected in accordance with local requirements. The Threaded Swivel Eye THS3 anchors are made of high quality steel and are designed with a safety factor of 5. Every Lifting System is individually tested at 3 times the working load and comes with its own unique certificate. The Threaded Swivel Eye should only be attached to the concrete unit and used after the concrete strength has reached 15 MPa. It is usually removed after the concrete elements have been installed. This lifting system is suitable for use with threaded socket cast in flush with the surface of the unit or recessed using recess formers. Ensure that the thread is fully mounted in the socket before lifting. THS3-M Product no. Thread Load group Axial load L a d D l 1 M [t] [kn] [mm] [mm] [mm] [mm] [mm] THS3-HD-M THS3-HD-M THS3-HD-M THS3-HD-M THS3-HD-M THS3-HD-M THS3-HD-M THS3-HD-M THS3-Rd Product no. Thread Load group Axial load L a d D l 1 Rd [t] [kn] [mm] [mm] [mm] [mm] [mm] THS3-HD-Rd THS3-HD-Rd THS3-HD-Rd THS3-HD-Rd THS3-HD-Rd THS3-HD-Rd THS3-HD-Rd THS3-HD-Rd Terwa reserves the right to make changes to the documentation at any time Page 42

43 THS3 APPLICATIONS SCREWING DETAILS Ensure that the thread is fully bottomed out in the socket before lifting. Any gap between the concrete element and the body of the lifting system is not permitted: the thread must be fully threaded inside the socket. The preferred option is the vertical lift. Normally the angle of lift (ß) should not be greater than 30. Pulling back towards the unit is not permitted. ADMISSIBLE LOAD DIRECTION Terwa reserves the right to make changes to the documentation at any time Page 43

44 Number of pieces or 4 3 or 4 Type of attachment Angle of inclination THS3-M/Rd WLL group Axial load Load group Axial load Load group Axial load Load group Axial load [kn] [kn] [kn] [kn] [kn] [kn] [kn] [kn] THS3-M/Rd THS3-M/Rd THS3-M/Rd THS3-M/Rd THS3-M/Rd THS3-M/Rd THS3-M/Rd THS3-M/Rd For an asymmetrical load distribution, the lifting capacities applicable to the 2 and 3 or 4 leg slings are the same as for 1 leg types at 90. The preferred option is the vertical lift. Normally the angle of lift (ß) should not be greater than 30. Pulling back towards the unit is not permitted. Terwa reserves the right to make changes to the documentation at any time Page 44

45 SPECIAL THREAD DESCRIPTION Terwa special thread Rd is a mix of standard Rd thread and a metric thread according to DIN 13. It has metric screw pitches but round thread geometry of thread flanks with a double angle of 60 and 30. For that reason, an anchor with special Rd thread can be used in combination with both metric and Rd threaded lifting systems. M thread bush and Rd thread bolt Rd thread bush and metric thread bolt Rd thread bush and Rd thread bolt Terwa reserves the right to make changes to the documentation at any time Page 45

46 CAST-IN LIFTING LOOPS TIL Cast-in Lifting Loops are the most economical lifting system. They require relatively large edge distances. Take the exposure of steel wire loops after the installation of the concrete unit into consideration. Once the unit is set in the final position, protruding loops can be cut off, if necessary, but the cut ends must be protected against corrosion to prevent staining from rust. The steel wire rope is more suitable for forming a cast-in loop because it is flexible, and the lifting loop made from reinforcing bar is liable to fatigue, especially if bent during angled lift. The minimum dimensions for installation in reinforced concrete are indicated in the table below. Additional lateral reinforcement may be required for acute angled lifts. Cast-in Lifting Loops are made of a highgrade steel wire AISI 1010 (W ), swaged in a ferrule made of AlMg1.8, with a fixing strip in the middle with an identification label, which must not slide down the hoop during casting and should remain visible. Each lifting loop has a label attached, marked with the admissible load and the code number of the testing. Cast-in Lifting Loops are zinc plated for protection against corrosion. These lifting systems are suitable for use through a single cycle from production to final installation. They are not suitable for multiple use applications. To choose the correct size for any lift, it is important to consider the angle of lift, the crane factor and the adhesion to the formwork. Cast-in lifting loops must be installed in the direction of the expected load. They should be suspended from supports attached to the formwork so that 2/3 of the loop will be cast in and 1/3 will remain exposed. The loops must be fastened to the reinforcement cage to avoid movement during concreting. Avoid bending the steel wire rope while the precast unit is in storage. Exposed loops can be attached to standard crane hooks, but the curvature radius of the crane hook should at least be equal to the diameter of the wire rope. It is essential to check that the wire rope is in good condition, with no broken, crushed or unravelled wire. Also, do not use if there are kinks in the loop or the wire rope is badly corroded! Cast-in Lifting Loops with any signs of damage should not be used. TIL Product no. Overall length Wire rope dimensions Weight Load group L d L f cu > 30 MPa [mm] [mm] [mm] [kg/pc] [t] TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL Terwa reserves the right to make changes to the documentation at any time Page 46

47 Longitudinal installation Transversal installation Installation details and reinforcement required for TIL Cast-in lifting system TIL Dimensions cast-in Reinforcement dimension Minimum width of precast element f e Min ls Min l s 2xb Load group f cu > 30 MPa [mm] [mm] [mm] [mm] [mm] [mm] [t] TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL Reinforcement must be designed by the lifting design engineer and TIL placed in accordance with the approved lifting design TIL Terwa reserves the right to make changes to the documentation at any time Page 47

48 TIL Installation dimensions Minimum width of precast element a/2 a s 2xb [mm] [mm] [mm] [mm] TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL TIL STORAGE REQUIREMENTS Lifting systems and anchors must be stored and protected in dry conditions, under a roof. Large temperature variations, snow, ice, humidity, or salt and saltwater impact may cause damage to anchors and shorten the service life. SAFETY INSTRUCTIONS Lifting components must be used by trained, experienced personnel thereby reducing the risk of major damage and injury. Every lifting process must be made according to the instructions. Obligatory instructions for safe working: - All lifting anchors must be operated manually - Inspect lifting anchors visually before use; check and clean all lifting inserts prior to use - Hook in all lifting systems separately, without using force - Respect local regulations for safe lifting and hoisting at all times. Terwa reserves the right to make changes to the documentation at any time Page 48

49 ACCESSORIES DOUBLE METRIC MOUNTING PLUG SN SN Product no. Thread Thread L M1 M2 [mm] SN M12-M SN M16-M SN M20-M SN M24-M SN M24-M SN M30-M SN M30-M SN M36-M SN M42-M SN M48-M SN M48-M SN M48-M Double metric mounting plug SN is used for fixing the anchors or the lifting sockets to the formwork with a screw. Terwa reserves the right to make changes to the documentation at any time Page 49

50 PLASTIC NAILING PLATE KU-10 The nailing plates KU-10 are used for affixing the anchors and the lifting sockets to the formwork with nails. The fixing flange ensures a minimuml recess around the head of the anchor. The recess is filled with fine concrete for protection against corrosion. KU-10 Product no. Thread Diam. D Diam. d s M [mm] [mm] [mm] Colour KU-10-M Red RAL 3020 KU-10-M Grey RAL 7043 KU-10-M Green RAL 6024 KU-10-M Blue RAL 5015 KU-10-M Violet blue RAL 5000 KU-10-M Orange RAL 2009 KU-10-M Brown RAL 8001 KU-10-M Black RAL 9017 The plastic nailing plates KU-10 are nailed to formwork. Using forming wax on the nailing plate makes it easier to remove and screw on the anchor or fixing insert. The anchor must be fastened to the reinforcement by suitable means so it does not move during concreting. After stripping, unscrew. Terwa reserves the right to make changes to the documentation at any time Page 50

51 PLASTIC NAILING PLATE KU-2 KU-02 Product no. Thread Diam. D Thickness M [mm] [mm] KU-02-M M KU-02-M M KU-02-M M KU-02-M M The nailing plates KU-02 are used for affixing the PSA or PSAD reinforcement coupler to the formwork with nails. These are suitable for fixing the PSA reinforcement coupler to the surface of the concrete units. STEEL MAGNETIC PLATE - TPM The plates with magnets TPM are used for affixing the anchors and the lifting sockets to the steel formwork. The fixing flange ensures a minimum recess around the head of the anchor. When using this magnetic recess former, it is very important that the surface of the formwork be clean. The recess is filled with fine concrete for protection against corrosion. TPM-10 Product no. Thread Diam. D s M [mm] [mm] TPM-10-M TPM-10-M TPM-10-M TPM-10-M TPM-10-M TPM-10-M TPM-10-M TPM-10-M Note: The magnets are high strength so please be careful of your hands when mounting them on the steel formwork. Terwa reserves the right to make changes to the documentation at any time Page 51

52 BREAKABLE FIXING PIN TBP Breakable fixing pin is used for affixing the anchors or the lifting sockets to the formwork. The Breakable fixing pin TBP is made of plastic nylon or polyamide 6. Working method: - Insert the Breakable fixing pin TBP into the formwork - Screw the anchor or the fixing insert onto the fixing pin TBP - Pour concrete - Remove the formwork; the fixing pin will break off in the formwork - Remove the remaining part of the fixing pin just before using the thread of the anchor Thread D TBP Product no. M [mm] TBP-M TBP-M TBP-M TBP-M Terwa reserves the right to make changes to the documentation at any time Page 52

53 DATA CLIP Identifying the lifting anchor embedded in concrete is easy using the Terwa DATA CLIP. The size, the maximum working load, the additional reinforcement steel diameter and the manufacturer are clearly marked on the ring. At the same time, each DATA CLIP has a unique colour code related to the anchor s load group. There are two lateral wings on the product, which permits the additional reinforcement steel on the anchor to be mounted easily in a safe zone, with 100% lifting capacity of the anchor. DATA CLIP Product no. Thread D h a d M [mm] [mm] [mm] [mm] Colour DATA CLIP -M Pink RAL 3015 DATA CLIP -M Oyster white RAL 1013 DATA CLIP -M Light green RAL 6019 DATA CLIP -M Light blue RAL 5012 DATA CLIP -M Lilac RAL 4005 DATA CLIP -M Sulphur yellow RAL 1016 DATA CLIP -M Light brown RAL 8001 DATA CLIP -M Dark grey RAL 7037 DATA CLIP Product no. Thread D h a d Rd [mm] [mm] [mm] [mm] Colour DATA CLIP -Rd Pink RAL 3015 DATA CLIP -Rd Oyster white RAL 1013 DATA CLIP -Rd Light green RAL 6019 DATA CLIP -Rd Light blue RAL 5012 DATA CLIP -Rd Lilac RAL 4005 DATA CLIP -Rd Sulphur yellow RAL 1016 DATA CLIP -Rd Light brown RAL 8001 DATA CLIP -Rd Dark grey RAL 7037 Terwa reserves the right to make changes to the documentation at any time Page 53

54 PLASTIC PLUG Plastic plugs are used to cover the bushes and to protect the sockets from rust and/or dirt. They are available in concrete grey and can therefore remain in the concrete element after installation for a finished look. PLASTIC PLUG Product no. Thread Diam. D L s M/Rd [mm] [mm] [mm] PLASTIC PLUG -M/Rd PLASTIC PLUG -M/Rd PLASTIC PLUG -M/Rd PLASTIC PLUG -M/Rd PLASTIC PLUG -M/Rd PLASTIC PLUG -M/Rd PLASTIC PLUG -M/Rd PLASTIC PLUG -M/Rd After removing the KU Nailing plate, mount the plastic plug inside the socket. It can also be used to protect the socket anchor s thread before installation, thereby preventing dirt from getting into the anchor s thread zone. Terwa reserves the right to make changes to the documentation at any time Page 54

55 COVER SEALING CAP TP-02 The Cover Sealing Cap is made of Stainless Steel. Its purpose is to protect the socket and give the concrete element a finished look. COVER SEALING CAP Product no. Thread Diam. D L s M/Rd [mm] [mm] [mm] M/Rd M/Rd M/Rd M/Rd M/Rd M/Rd Mount the Cap in the socket after removing the Nailing plate. Terwa reserves the right to make changes to the documentation at any time Page 55

56 COVER SEALING CAP TP-10 The Cover Sealing Cap is made of Stainless Steel. Its purpose is to protect the socket and give the concrete element a finished look. COVER SEALING CAP Product no. Thread Diam. D s M/Rd [mm] [mm] M/Rd M/Rd M/Rd M/Rd M/Rd M/Rd M/Rd Mount the Cap in the socket after removing the Nailing plate. Terwa reserves the right to make changes to the documentation at any time Page 56