1 Architectural Inspection Building Assessment Survey Asset: P.S QUEENS, STREET, New York, Inspection Id Inspection Type Time In Last Edited SA : Architectural - Senior :30 AM :09 PM AA : Architectural - Associate :07 AM :25 PM Asset Data Was the building fully accessible for inspection Principal(s) Information Custodian Fireman Principal Name Organization Did you meet with this Principal? Did this Principal provide feedback? Summary of Principal's Feedback Answer Yes Eileen Davies P.S Queens Yes Yes The Principal's comments are as follows: 1. Install electrical wiring and receptacles for the newly installed air conditioners. 2. Re-key the interior doors so a master key can unlock the doors. 3. Replace the PA System. 4. Install centralized clocks inside classrooms. 5. Repair camera adjacent to Exit 9. Dale Brown John Bellon Building Square Footage Comments on the Area Comments on the Stories (Floors) plus Basements 3+B Comments on the Number of Classrooms 43 None Comments on the Year Built 1965 Student Population 679 Staff Population 130 Weather Facade Photo Fair Corner of 159th Avenue and 88th Street - Southeast view PB/A&W Page 1 of 39

2 Main Entrance Photo Building Assessment Survey Roof Photo Facade A - 88th Street Roof 1 - Southeast view Have any Systems/Major Building Components been upgraded? Yes Systems: New Boiler, Exhaust system and Electrical Panel system; Exterior Door repairs; New Generator and Dunnage Steel; Repairs to Areaways Year: 2015 Systems: Room 211 and Staircase B vinyl Flooring replacement; Bulkhead C Roof repairs; Partial Exterior Concrete replacement Year: 2014 Systems: Partial Classroom, Gymnasium and Corridor vinyl floor replacement Year: 2013 Systems: Partial Classroom vinyl floor replacement; Partial Exterior Door replacement; Complete Areaway Grating and support replacement Year: 2012 Systems: Partial Exterior Door replacement; Partial Exterior Wall repairs; New Windows, Guards and Shades; Partial Window Lintel replacement; Cafeteria vinyl Flooring replacement Year: 2010 Systems: New Science Lab PB/A&W Page 2 of 39

3 Architectural Inspection Have there been any New Building Additions? Tandem Schools? Leased Space? Building Assessment Survey Year: 2007 Systems: New Roofing and Flashing Year: 2000 No No No Priority Priority Exist Last Year? Priority Category Description Component Affected Location Description Person(s) Notified Person(s) Title PhotoImage No condition recorded Structural Engineer Required Structural Type Description Component Affected Location Description Person(s) Notified Person(s) Title PhotoImage No condition recorded Accessibility Accessibility Status Is the primary or secondary entrance on an accessible route? Is the building a multi-story building? Are all floors of the building accessible through compliant means? Are SOME floors other than the 1st floor and basement accessible through compliant means? Do any of the following spaces exist on the First floor? Classroom, Art Room, Auditorium, Cafeteria, Computer, Gymnasiums, Library, Multipurpose Room, Science Labs For the rooms that do exist, are SOME of them accessible on the 1st floor? Boys and Girls or Unisex accessible toilets exist on the 1st floor? Yes Yes No No Yes Yes No Physical Breakdown Structure Exists Complies Required FUNCTIONAL ACCESSIBILITY Exterior Routes Exterior Entrances & Exits Yes Exterior H/C Lifts No No Exterior Ramps and Railings Yes Yes Interior Routes Corridor and Lobby H/C Lifts No No Interior Corridor Doors and Hardware Yes Yes Interior Corridors and Lobbies Yes Interior Elevators No Interior Lobby Doors and Hardware Yes Interior Ramps No Rooms & Spaces Art Rooms Room 325 No Not on Accessible Route Auditorium 1st Floor No No Stage Access Cafeteria 1st Floor Yes Classrooms 1st Floor Yes Computer Rooms Room 317, 329 No Not on Accessible Route Gymnasium 1st Floor Yes Library Room 229 No Not on Accessible Route Main Office Room 123 Yes PB/A&W Page 3 of 39

4 Building Assessment Survey Physical Breakdown Structure Exists Complies Required Rooms & Spaces Multi-purpose Room Nurse's Room Room 115 Yes Pool Science Lab Room 326 No Not on Accessible Route Toilet Rooms (Boys) 1st Floor No Clear opening < 32" Water Closet Arrangement Urinal Arrangement Turning Radius Sink Arrangement No Lever-type Hardware Accessory Arrangement Toilet Rooms (Girls) 1st Floor No Accessory Arrangement Clear opening < 32" No Lever-type Hardware Sink Arrangement Turning Radius Water Closet Arrangement Toilet Rooms (Staff) 1st Floor No Clear opening < 32" No Lever-type Hardware Sink Arrangement Turning Radius Urinal Arrangement Water Closet Arrangement No No Building Template Inspection Architectural EXTERIOR AREAWAY Instance on AW1 - AW2 Instance Instance Quantity 2 Instance 3 - Fair EACH AREAWAY SLAB: CRACKS AND SPALLING PB/A&W Page 4 of 39

5 EXTERIOR AREAWAY Building Assessment Survey Quantity 10 REPAIR Photo1 AW1 AREAWAY WALLS: CRACKS AND SPALLING Quantity 30 REPAIR PB/A&W Page 5 of 39

6 EXTERIOR AREAWAY Photo1 Building Assessment Survey AWNINGS AND CANOPIES CHIMNEY Material Type(s) AW1 Masonry 3 - Fair BRICK: OPEN JOINTS Quantity 30 REPOINT Photo1 COPING CORNICE Chimney PB/A&W Page 6 of 39

7 EXTERIOR DOORS DOORS AND FRAMES Building Assessment Survey Between Fair and Poor METAL CLAD: DETERIORATED DOOR AND FRAME - MAJOR DETERIORATION Quantity 2 EACH Urgency of Action PRIORITY 4 Photo1 Facade A METAL: DETERIORATED DOOR AND FRAME - MAJOR DETERIORATION Quantity 2 EACH Urgency of Action PRIORITY 4 PB/A&W Page 7 of 39

8 EXTERIOR DOORS DOORS AND FRAMES Photo1 Building Assessment Survey Facade A DOOR HARDWARE 3 - Fair LINTELS TRANSOM/SIDE LIGHT EXTERIOR WALLS Material Type(s) Masonry, Concrete Replacement Quantity 35,000 Replacement Uom Instance on All Facades Instance 3 - Fair Instance Quantity 35,000 Instance CAST IN PLACE / PRE-CAST CONCRETE: OPEN JOINTS PB/A&W Page 8 of 39

9 EXTERIOR EXTERIOR WALLS Elevation Building Assessment Survey Quantity 25 L.F. REPOINT Photo1 Facade C BRICK: OPEN JOINTS Elevation Quantity 5,000 REPOINT PB/A&W Page 9 of 39

10 Building Assessment Survey Architectural Inspection EXTERIOR EXTERIOR WALLS Urgency of Action PRIORITY 4 Photo1 Facade A EXTERIOR SOFFITS LOADING DOCK LOUVER PARAPETS Material Type(s) Masonry Replacement Quantity 5,000 Replacement Uom C.F. Instance on Facade A, E and F Instance Instance Quantity 5,000 Instance C.F. PLAZA DECK ROOF Roofing Replacement Quantity 38,000 Replacement Uom ROOF HATCH/SMOKE HATCH LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS ROOF BARRIER 3 - Fair RAILINGS/PANELS: DETERIORATED, MINOR RUSTING PB/A&W Page 10 of 39

11 EXTERIOR ROOF Roofing ROOF BARRIER Building Assessment Survey Quantity 100 MAINTENANCE Photo1 No photo recorded RAILINGS/PANELS: DETERIORATED, MAJOR RUSTING Quantity 10 Urgency of Action PRIORITY 4 Photo1 ROOF CAGE ROOF FENCE Roof 1 PB/A&W Page 11 of 39

12 EXTERIOR ROOF Roofing ROOFING Instance on Built-Up: All Roofs Instance Instance Quantity 38,000 Instance Does the roof have major mechanical equipment sitting on Dunnage Steel less than 18" above the Roofing? Installation Year 2000 Source of Installation Building Assessment Survey Between Fair and Poor No Custodial Staff BUILT-UP: ROOFING: MAJOR ACTIVE ROOF LEAKS IN INSTRUCTIONAL SPACE Quantity 1,000 Urgency of Action PRIORITY 5 Photo1 ROOFING WITHOUT MAJOR EQUIPMENT REMOVAL ROOFING DRAINS Specialties BULKHEAD/PENTHOUSE Room 305. Room 300 similar 3 - Fair BULKHEAD/PENTHOUSE WALLS/EXTERIOR: OPEN JOINTS PB/A&W Page 12 of 39

13 EXTERIOR ROOF Specialties BULKHEAD/PENTHOUSE Building Assessment Survey Quantity 50 REPOINT Photo1 CUPOLA/ SPIRES/ TOWERS DORMER DUNNAGE STEEL SKYLIGHT/ROOF VENT Material Type(s) ROOF/GRAVITY TANK STAIRS/RAMPS: EXTERIOR BUILDING CHEEK/FLANK WALLS BH1 1 - Good Other 5 - Poor STONE: OPEN JOINTS PB/A&W Page 13 of 39

14 Building Assessment Survey Architectural Inspection EXTERIOR STAIRS/RAMPS: EXTERIOR BUILDING CHEEK/FLANK WALLS Quantity 20 REPOINT Photo1 Facade A CAST IN PLACE CONCRETE: CRACKS/SPALLING - MAJOR Quantity 30 Urgency of Action PRIORITY 4 PB/A&W Page 14 of 39

15 Building Assessment Survey Architectural Inspection EXTERIOR STAIRS/RAMPS: EXTERIOR BUILDING CHEEK/FLANK WALLS Photo1 Facade F BRICK: CRACKS/SPALLING - MINOR Quantity 10 REPAIR Photo1 Facade C BRICK: OPEN JOINTS PB/A&W Page 15 of 39

16 Building Assessment Survey Architectural Inspection EXTERIOR STAIRS/RAMPS: EXTERIOR BUILDING CHEEK/FLANK WALLS Quantity 15 REPOINT Photo1 RAILINGS Facade C 3 - Fair RUST - MINOR Quantity 30 L.F. MAINTENANCE PB/A&W Page 16 of 39

17 EXTERIOR STAIRS/RAMPS: EXTERIOR RAILINGS Photo1 Building Assessment Survey Facade C RUST - MAJOR Quantity 10 L.F. Urgency of Action PRIORITY 4 Photo1 STAIRS/RAMPS Facade C 5 - Poor STONE: DETERIORATED SUBSTRATE PB/A&W Page 17 of 39

18 EXTERIOR STAIRS/RAMPS: EXTERIOR STAIRS/RAMPS Building Assessment Survey Quantity 30 SUBSTRATE AND RESET Urgency of Action PRIORITY 4 Photo1 Facade F STONE: OPEN JOINTS Quantity 20 L.F. REPOINT PB/A&W Page 18 of 39

19 EXTERIOR STAIRS/RAMPS: EXTERIOR STAIRS/RAMPS Photo1 Building Assessment Survey Facade E STONE: CRACKS, SPALLING Quantity 10 Photo1 Facade D WINDOWS Replacement Quantity 12,000 Replacement Uom EXTERIOR GUARDS LINTELS PB/A&W Page 19 of 39

20 Building Assessment Survey Architectural Inspection EXTERIOR WINDOWS WINDOWS Material Type(s) Aluminum Instance on Aluminum - Double Hung: All Facades Instance 1 - Good Instance Quantity 12,000 Instance Installation Year 2010 Source of Installation Custodial Staff INTERIOR POOLS STRUCTURAL COLUMNS/BEAMS/BEARING WALLS FLOOR STRUCTURE FOUNDATION WALLS Material Type(s) Location/Instance Quantity 50 Concrete 3 - Fair CONCRETE: WATER INFILTRATION IN NON- INSTRUCTIONAL SPACE Boiler Room Urgency of Action PRIORITY 5 Purpose of Action LEVEL 5 Photo1 INSTALL WATERPROOFING Boiler Room ROOF STRUCTURE Location/Instance Quantity Fair CONCRETE: CRACKED/SPALLED/REINFORCEMENT EXPOSED Room 305, Room 300 and Stair 3 similar. REPAIR PB/A&W Page 20 of 39

21 Building Assessment Survey Architectural Inspection INTERIOR STRUCTURAL ROOF STRUCTURE Urgency of Action PRIORITY 4 Purpose of Action LEVEL 5 Photo1 Room 300 VAULTS-BUNKERS Foundation Walls CRACKS, SPALLING Location/Instance Boiler Room Quantity 10 REPAIR Purpose of Action LEVEL 5 Photo1 Boiler Room Slab Structure Location/Instance Quantity 10 CONCRETE BEAMS: CRACKS/SPALLED/REINFORCEMENT EXPOSED Boiler Room REPAIR Purpose of Action LEVEL 5 PB/A&W Page 21 of 39

22 INTERIOR STRUCTURAL VAULTS-BUNKERS Slab Structure Photo1 Building Assessment Survey Boiler Room Vault/Ash Hoist Doors and Framing AUDITORIUM Seats Ceiling Seats Door(s) Seats Fixed H/C Lift Seats Fixed Seating Seats 3 - Fair DAMAGED/BROKEN/INOPERABLE Location/Instance Seats C/1,3,5,7, H/9, and others Quantity 15 EACH Photo1 Seat C/1 PB/A&W Page 22 of 39

23 INTERIOR AUDITORIUM Fixed Seating Building Assessment Survey Floor Finish Seats SHEET VINYL: BROKEN/DETERIORATED Location/Instance Near Stage, in the aisle Quantity 100 Photo1 Near Stage Sliding-folding Partition Seats Stage Seats Stage Seats 3 - Fair RAILINGS/MISSING Location/Instance Left, Right Stage Quantity 10 L.F. Urgency of Action PRIORITY 5 Purpose of Action LEVEL 6 Photo1 Left Stage PB/A&W Page 23 of 39

24 INTERIOR AUDITORIUM Stage Stage Building Assessment Survey Stage Curtain Rigging Seats Stage Curtains Seats Walls Seats MASONRY: CRACKS/SPALLING Location/Instance On Stage at rear wall Quantity 30 Photo1 On Stage at rear wall Window Curtains/Shades/Blinds Seats CAFETERIA Ceiling Door(s) Location/Instance Quantity Fair WOOD: DETERIORATED DOOR Main entrance PB/A&W Page 24 of 39

25 Building Assessment Survey Architectural Inspection INTERIOR CAFETERIA Door(s) EACH MAINTENANCE Photo1 Main entrance Fixed Equipment Floor Finish Sliding-folding Partition Stage Walls Window Curtains/Shades/Blinds CLASSROOMS/CORRIDORS/ADMIN SPACES Ceiling ACOUSTIC TILES ON PLASTER: DAMAGED/MISSING Location/Instance Corridor near Room 229, by Stair B/1,3 Quantity 20 PB/A&W Page 25 of 39

26 Building Assessment Survey Architectural Inspection INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Ceiling Photo1 Corridor near Stair B/3 PLASTER: CRACKS/SPALLING - ACTIVE LEAK Location/Instance Rooms 300, 305 Quantity 50 Urgency of Action PRIORITY 5 Photo1 Room 305 Door(s) 4 - Between Fair and Poor METAL: DETERIORATED DOOR Location/Instance Room 317 Quantity 1 EACH MAINTENANCE Photo1 PB/A&W Page 26 of 39

27 INTERIOR Building Assessment Survey CLASSROOMS/CORRIDORS/ADMIN SPACES Door(s) Room 317 WOOD: DETERIORATED DOOR Location/Instance Rooms 104, 107, 205, 305 Quantity 4 EACH MAINTENANCE Photo1 Room 305 Floor Finish VINYL TILES: BROKEN/DETERIORATED/MISSING TILES Location/Instance Rooms 302, 305, Corridor near Rooms 215, 224 Quantity 300 Photo1 Room 300 Walls Specialties GYMNASIUM Ceiling PB/A&W Page 27 of 39

28 Building Assessment Survey Architectural Inspection INTERIOR GYMNASIUM TECTUM: DAMAGED/MISSING Location/Instance Near center toward the rear Quantity 50 Photo1 Door(s) Fixed Equipment Floor Finish Seating Sliding-folding Partition Stage Walls Window Curtains/Shades/Blinds INTERIOR DOOR HARDWARE INTERIOR GUARDS Near center toward the rear 3 - Fair PB/A&W Page 28 of 39

29 Building Assessment Survey Architectural Inspection INTERIOR INTERIOR GUARDS KITCHEN Ceiling Door(s) Floor Finish CERAMIC TILE: DETERIORATED SUBSTRATE Location/Instance Near the servery entrance side Quantity 10 Photo1 Near the servery entrance side CERAMIC TILE: BROKEN/MISSING TILES Location/Instance Food preparation area Quantity 20 PB/A&W Page 29 of 39

30 INTERIOR KITCHEN Floor Finish Photo1 Building Assessment Survey Food preparation area Walls PLASTER: CRACKS/SPALLING Location/Instance Office Quantity 10 Photo1 LIBRARY Instance on Room 229 Built-in Furnishing Instance on Room 229 Ceiling Instance on Room 229 Door(s) Instance on Room 229 Floor Finish Office PB/A&W Page 30 of 39

31 Building Assessment Survey Architectural Inspection INTERIOR LIBRARY Floor Finish Instance on Room 229 SHEET VINYL: BROKEN/DETERIORATED Location/Instance Near the center, left side of the room Quantity 10 Photo1 Left side of the room Walls Instance on Room 229 LOCKER ROOM MULTI-PURPOSE ROOM SCIENCE DEMO ROOM SCIENCE LAB Instance on Room 326 Alternative use Fixed Equipment Instance on Room 326 SCIENCE PREP ROOM SHOWER ROOM STAIRS/RAMPS: INTERIOR Ceiling Do Letter Stair Signs Exist? No Yes Location/Instance Stair C/3 Quantity 40 PLASTER: CRACKS/SPALLING Urgency of Action PRIORITY 4 Purpose of Action LEVEL 4 PB/A&W Page 31 of 39

32 INTERIOR STAIRS/RAMPS: INTERIOR Ceiling Photo1 Building Assessment Survey Stair C/ M Door(s) Partition Railings Stairs and Landings Walls TOILET ROOMS - STAFF Ceiling Door(s) 5 - Poor WOOD: DETERIORATED DOOR Location/Instance Room 307 Quantity 1 EACH MAINTENANCE Photo1 Room 307 PB/A&W Page 32 of 39

33 INTERIOR TOILET ROOMS - STAFF Door(s) Building Assessment Survey Floor Finish Stalls 5 - Poor RUST - MAJOR Location/Instance Room 203, 307, inside Room 142 Quantity 3 EACH Photo1 Room 307 Walls CERAMIC TILE: BROKEN/ MISSING Location/Instance Inside Room 142 Quantity 10 Photo1 Inside Room 142 TOILET ROOMS - STUDENTS Ceiling PB/A&W Page 33 of 39

34 Building Assessment Survey Architectural Inspection INTERIOR TOILET ROOMS - STUDENTS Ceiling Door(s) 5 - Poor WOOD: DETERIORATED DOOR Location/Instance Rooms 116, 216, 322 Quantity 3 EACH MAINTENANCE Photo1 Room 216 Floor Finish Stalls 4 - Between Fair and Poor RUST - MAJOR Location/Instance Rooms 116, 322 Quantity 5 EACH Photo1 Walls Room 322 CERAMIC TILE: BROKEN/ MISSING PB/A&W Page 34 of 39

35 Building Assessment Survey Architectural Inspection INTERIOR TOILET ROOMS - STUDENTS Walls Location/Instance Rooms 216, 316, Quantity 10 Photo1 Room 216 LIFE SAFETY F.D. HOLDING AREA STEEL STAIRS SITE CONTAINERIZATION 5 - Poor FENCING MISSING Location/Instance 89th Street Quantity 300 INSTALL NEW Photo1 No photo recorded CONTAINER DAMAGED Location/Instance 89th Street Quantity 2 EACH PB/A&W Page 35 of 39

36 SITE CONTAINERIZATION Photo1 Building Assessment Survey th Street Drainage System for Asphalt Drainage System for Concrete Catch Basins/Manhole - Surrounded by concrete Culverts - Concrete Covering Drainage System for Soil Catch Basins/Manhole - Surrounded by Soil Culverts - Soil Covering DRINKING FOUNTAINS FENCES 3 - Fair CONCRETE CURB: DAMAGED/DETERIORATED Location/Instance 159th Avenue Quantity 10 Photo1 159th Avenue WROUGHT IRON: DAMAGED/DETERIORATED Location/Instance 88th Street, 89th Street, 159th Avenue Quantity 320 PB/A&W Page 36 of 39

37 Building Assessment Survey Architectural Inspection SITE FENCES Photo1 88th Street IRRIGATION SYSTEM PAVING Student Non-Use Gravel Exists? No Asphalt Concrete 3 - Fair CRACKS - MAJOR Location/Instance 89th Street Quantity 225 Photo1 89th Street Pavers Student Use Site Sidewalks & Walkways Asphalt 3 - Fair HEAVING Location/Instance East walkway between the school and NYC Park Quantity 80 PB/A&W Page 37 of 39

38 Building Assessment Survey Architectural Inspection SITE PAVING Site Sidewalks & Walkways Asphalt Photo1 East walkway between the school and NYC Park Concrete 3 - Fair DAMAGED/DETERIORATED/MISSING SECTIONS Location/Instance 88th Street, Southeast entrance by NYC Park Quantity 75 Photo1 88th Street Pavers DOT Sidewalk Asphalt Concrete Location/Instance Quantity Fair DAMAGED/DETERIORATED/MISSING SECTIONS 88th Street, 89th Street, 159th Avenue PB/A&W Page 38 of 39

39 Building Assessment Survey Architectural Inspection SITE PAVING DOT Sidewalk Concrete Photo1 Pavers PLAYGROUNDS PLAYING SURFACE RETAINING WALLS SEATING SITE WALLS (NOT RETAINING WALLS) STAIRS/RAMPS: EXTERIOR 88th Street PB/A&W Page 39 of 39