NYC Department of Education

Size: px
Start display at page:

Download "NYC Department of Education"

Transcription

1 Architectural Inspection Building Assessment Survey Asset: SECOND OPPORTUNITY SCHOOL - K, 797 BUSHWICK AVENUE, New York, Inspection Id Inspection Type Time In Last Edited SA : Architectural - Senior :08 AM :28 PM AA : Architectural - Associate :15 AM :17 PM Asset Data Was the building fully accessible for inspection Principal(s) Information Custodian Fireman Principal Name Answer Yes Catherine Reilly Organization Bushwick Leadership High School for Academic Excellence - Brooklyn Did you meet with this Principal? Did this Principal provide feedback? Summary of Principal's Feedback Building Square Footage Comments on the Area Comments on the Stories (Floors) plus Basements Comments on the Number of Classrooms 29 Yes Yes The Principal's comments are as follows: 1. The heating in the building does not function properly because of radiator valve issues and no thermostats. 2. All Toilet Rooms need to be upgraded and are not HC Compliant. 3. The Elevators need to be upgraded. There are three total but only one operates. Was not present Joseph Falco ne 4+B+SB Comments on the Year Built 1890 Student Population 282 Staff Population 58 Weather Facade Photo Fair Corner of Bushwick Avenue and Stockholm Street - rthwest View PB/A&W Page 1 of 40

2 Main Entrance Photo Building Assessment Survey Roof Photo Façade A - Dekalb Avenue Roof 1 - West View Have any Systems/Major Building Components been upgraded? Have there been any New Building Additions? Tandem Schools? Leased Space? Yes Systems: Exterior Modernization Project including Modified Bitumen Roofing replacement, New Metal Roof (Roof 28), Slate Roof repairs, New Roof Hatches, Cupola repairs; Flashing, Parapets and Coping replacement; Completed Exterior Masonry Wall repointing and replacement; Window and Door Lintel repairs; Site Paving and Landscape repairs and replacement Year: 2015 Systems: Partial Exterior Door repairs Year: 2013 Systems: Roofs 9, 12, 14 repairs; Partial Floor Structure repairs Year: 2012 Systems: Library Upgrades Year: 2011 Systems: Areaway Retaining Walls rebuilt Year: 2009 Systems: New Science Lab and Prep Room Year: 2008 PB/A&W Page 2 of 40

3 Priority Building Assessment Survey Priority Exist Last Year? Priority Category Description Component Affected Location Description Person(s) tified Person(s) Title PhotoImage Damaged/Deteri orated Railings Missing areaway railing is a potential safety hazard. EXTERIOR AREAWAY Basement areaway at the northwest side of the building near the corner of DeKalb and Evergreen Avenues. Joseph Falco Fireman Yes Missing Interior Fire Doors Missing Fire Door is a potential safety hazard. INTERIOR CLASSROOMS /CORRIDORS/ ADMIN SPACES Door(s) Corridor Near Rooms 102, 109, 204, 218, 310, 313, 316 Joseph Faldo Fireman Structural Engineer Required Structural Type Description Component Affected Location Description Person(s) tified Person(s) Title PhotoImage condition recorded Accessibility Accessibility Status Is the primary or secondary entrance on an accessible route? Is the building a multi-story building? Are all floors of the building accessible through compliant means? Are SOME floors other than the 1st floor and basement accessible through compliant means? Is there at least one classroom accessible in the building? Is there at least one Boys and Girls or Unisex toilet accessible in the building? Yes Yes Yes Yes Physical Breakdown Structure Exists Complies Required FUNCTIONAL ACCESSIBILITY Exterior Routes Exterior Entrances & Exits Exterior H/C Lifts Exterior Ramps and Railings Yes Yes Interior Routes Corridor and Lobby H/C Lifts Yes Interior Corridor Doors and Hardware Yes Yes Interior Corridors and Lobbies Change in Elevation Interior Elevators Yes Yes Interior Lobby Doors and Hardware Interior Ramps Rooms & Spaces Art Rooms Auditorium Cafeteria Classrooms 1st - 3rd Floor Yes PB/A&W Page 3 of 40 Yes Yes

4 Building Assessment Survey Physical Breakdown Structure Exists Complies Required Rooms & Spaces Computer Rooms Rooms 208 Yes Gymnasium Library 1st Floor Yes Main Office Room 103 Yes Multi-purpose Room 1st Floor - Center, East Yes Nurse's Room Room 206 Yes Pool Science Lab Rooms 201, 203, 316 Yes Toilet Rooms (Boys) 1st - 3rd Floor Water Closet Arrangement Urinal Arrangement Turning Radius Clear opening < 32" Toilet Rooms (Girls) 1st - 3rd Floor Water Closet Arrangement Turning Radius Clear opening < 32" Toilet Rooms (Staff) 1st - 3rd Floor Lever-type Hardware Water Closet Arrangement Urinal Arrangement Turning Radius Clear opening < 32" Building Template Inspection Architectural EXTERIOR AREAWAY Instance on AW1 - AW10 Instance 3 - Fair Instance Quantity 10 Instance EACH AREAWAY WALLS: CRACKS AND SPALLING PB/A&W Page 4 of 40

5 EXTERIOR AREAWAY Roof Plan reference Building Assessment Survey Quantity 10 Urgency of Action PRIORITY 4 Photo1 Roof Plan reference AW1 AREAWAY STAIRS: MISSING RAILINGS Quantity 10 L.F. Urgency of Action PRIORITY 5 Purpose of Action LEVEL 6 PB/A&W Page 5 of 40

6 EXTERIOR AREAWAY Photo1 Building Assessment Survey Roof Plan reference AW1 AREAWAY WALLS: DETERIORATED COPING STONE Quantity 150 Urgency of Action PRIORITY 4 Photo1 AW3 AREAWAY WALLS: OPEN JOINTS PB/A&W Page 6 of 40

7 EXTERIOR AREAWAY Roof Plan reference Building Assessment Survey Quantity 80 REPAIR Photo1 Roof Plan reference AW3 AREAWAY WALLS: OPEN JOINTS Quantity 20 REPAIR Urgency of Action PRIORITY 4 PB/A&W Page 7 of 40

8 EXTERIOR AREAWAY Photo1 Building Assessment Survey AWNINGS AND CANOPIES CHIMNEY Material Type(s) Roof Plan reference AW3 Masonry 3 - Fair BRICK: OPEN JOINTS Quantity 50 REPOINT Photo1 COPING CORNICE Chimney Good PB/A&W Page 8 of 40

9 EXTERIOR CORNICE DOORS DOORS AND FRAMES Roof Plan reference Building Assessment Survey Good METAL CLAD: DETERIORATED DOOR AND FRAME - MAJOR DETERIORATION Quantity 1 EACH Urgency of Action PRIORITY 4 Photo1 Façade C DOOR HARDWARE LINTELS TRANSOM/SIDE LIGHT EXTERIOR WALLS Material Type(s) Masonry Replacement Quantity 40,000 Replacement Uom Instance on All Facades Instance Instance Quantity 40,000 PB/A&W Page 9 of 40

10 EXTERIOR EXTERIOR WALLS Instance Roof Plan reference Building Assessment Survey BRICK: RELIEVING ANGLES - MINOR DETERIORATION Elevation Quantity 10 L.F. MAINTENANCE Photo1 EXTERIOR SOFFITS LOADING DOCK LOUVER PARAPETS Material Type(s) photo recorded Masonry Replacement Quantity 8,500 Replacement Uom Instance on Roofs 3, 4, 10-13, 18, 21, 24 Instance C.F. 1 - Good Instance Quantity 8,500 Instance PLAZA DECK Instance on Concrete: Roof 17 & Near Chimney 1 Instance C.F. 3 - Fair Instance Quantity 1,800 PB/A&W Page 10 of 40

11 Building Assessment Survey Architectural Inspection EXTERIOR PLAZA DECK Instance Installation Year 2015 Source of Installation Custodial Staff CONCRETE: MINOR CRACKS Roof Plan reference Quantity 25 REPAIR Photo1 Plaza Deck ROOF Roofing Replacement Quantity 26,000 Replacement Uom ROOF HATCH/SMOKE HATCH LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS ROOF BARRIER ROOF CAGE ROOF FENCE ROOFING Instance on Slate Roof: Roofs 1, 2, 5, 8, 18, 20, 25, 29, 30 Instance 1 - Good 1 - Good PB/A&W Page 11 of 40

12 EXTERIOR ROOF Roofing ROOFING Instance Quantity 14,900 Instance Does the roof have major mechanical equipment sitting on Dunnage Steel less than 18" above the Roofing? Installation Year 1985 Source of Installation Instance on Modified Bitumen: Roof 24 Instance Instance Quantity 800 Instance Does the roof have major mechanical equipment sitting on Dunnage Steel less than 18" above the Roofing? Custodial Staff Installation Year 2015 Source of Installation Roof Plan reference Building Assessment Survey Between Fair and Poor Custodial Staff MODIFIED BITUMEN: ROOFING: MINOR LEAKAGE Quantity 20 REPAIR Urgency of Action PRIORITY 5 Photo1 Roof 24 - Room 313 has Minor Leakage Instance on Metal: Roof 28 Instance 1 - Good Instance Quantity 300 Instance Does the roof have major mechanical equipment sitting on PB/A&W Dunnage Steel less than 18" above the Roofing? Page 12 of 40

13 EXTERIOR ROOF Roofing ROOFING Dunnage Steel less than 18" above the Roofing? Installation Year 2015 Source of Installation Instance on Modified Bitumen: Roofs 3, 4, 6, 7, 9, 10-16, 19, 21, 23, 26, 27 Instance Custodial Staff 1 - Good Instance Quantity 10,000 Instance Does the roof have major mechanical equipment sitting on Dunnage Steel less than 18" above the Roofing? Installation Year 2015 Source of Installation ROOFING DRAINS Specialties BULKHEAD/PENTHOUSE CUPOLA/ SPIRES/ TOWERS DORMER DUNNAGE STEEL SKYLIGHT/ROOF VENT ROOF/GRAVITY TANK STAIRS/RAMPS: EXTERIOR BUILDING CHEEK/FLANK WALLS Roof Plan reference Building Assessment Survey Custodial Staff 4 - Between Fair and Poor CAST IN PLACE CONCRETE: CRACKS/SPALLING - MINOR Quantity 10 REPAIR PB/A&W Page 13 of 40

14 Building Assessment Survey Architectural Inspection EXTERIOR STAIRS/RAMPS: EXTERIOR BUILDING CHEEK/FLANK WALLS Photo1 Roof Plan reference Façade P CAST IN PLACE CONCRETE: CRACKS/SPALLING - MAJOR Quantity 20 Urgency of Action PRIORITY 4 Photo1 RAILINGS STAIRS/RAMPS Façade P 4 - Between Fair and Poor CONCRETE: CRACKS/SPALLING - MAJOR PB/A&W Page 14 of 40

15 EXTERIOR STAIRS/RAMPS: EXTERIOR STAIRS/RAMPS Roof Plan reference Building Assessment Survey Quantity 20 Urgency of Action PRIORITY 4 Photo1 Façade P WINDOWS Replacement Quantity 12,000 Replacement Uom EXTERIOR GUARDS 3 - Fair RUST - MINOR Roof Plan reference PB/A&W Page 15 of 40

16 EXTERIOR WINDOWS EXTERIOR GUARDS Elevation Building Assessment Survey Quantity 140 MAINTENANCE Photo1 photo recorded LINTELS WINDOWS Material Type(s) Aluminum Instance on Aluminum - Double Hung: All Facades Instance 3 - Fair Instance Quantity 12,000 Instance Installation Year 1985 Source of Installation Custodial Staff ALUMINUM - DOUBLE HUNG: INOPERABLE BALANCE Roof Plan reference Elevation PB/A&W Page 16 of 40

17 Building Assessment Survey Architectural Inspection EXTERIOR WINDOWS WINDOWS Quantity 10 EACH MAINTENANCE Photo1 photo recorded ALUMINUM - DOUBLE HUNG: BEYOND USEFUL LIFE Location/Instance Aluminum - Double Hung: All Facades Quantity 12,000 Urgency of Action PRIORITY 1 Photo1 photo recorded INTERIOR POOLS STRUCTURAL COLUMNS/BEAMS/BEARING WALLS 3 - Fair WOOD COLUMNS/BEAMS: DETERIORATED Location/Instance Basement Quantity 20 L.F. Urgency of Action PRIORITY 5 Purpose of Action LEVEL 5 Photo1 Basement Location/Instance Quantity 20 WOOD COLUMNS/BEAMS: DEFLECTED/DISPLACED Basement L.F. Urgency of Action PRIORITY 5 Purpose of Action LEVEL 5 PB/A&W Page 17 of 40

18 Building Assessment Survey Architectural Inspection INTERIOR STRUCTURAL COLUMNS/BEAMS/BEARING WALLS Photo1 Basement STEEL COLUMNS/BEAMS: MINOR RUSTING Location/Instance Boiler Room, Basement Quantity 200 REPAIR AND REPAINT Purpose of Action LEVEL 5 Photo1 Boiler Room FLOOR STRUCTURE 4 - Between Fair and Poor CONCRETE: CRACKS/SPALLED/REINFORCEMENT EXPOSED Location/Instance Boiler Room, Basement Quantity 300 REPAIR Purpose of Action LEVEL 5 Photo1 PB/A&W Page 18 of 40

19 INTERIOR STRUCTURAL FLOOR STRUCTURE Building Assessment Survey Boiler Room FOUNDATION WALLS Material Type(s) Location/Instance Quantity 50 Concrete, Masonry 4 - Between Fair and Poor CONCRETE: WATER INFILTRATION IN NON- INSTRUCTIONAL SPACE Boiler Room Urgency of Action PRIORITY 5 Purpose of Action LEVEL 5 Photo1 INSTALL WATERPROOFING Boiler Room Location/Instance Quantity 20 CONCRETE: CRACKED/SPALLED/REINFORCEMENT EXPOSED Gas Meter Room REPAIR Purpose of Action LEVEL 5 Photo1 Gas Meter Room Location/Instance Quantity 40 STONE RUBBLE: OPEN JOINTS Basement PB/A&W Page 19 of 40

20 Building Assessment Survey Architectural Inspection INTERIOR STRUCTURAL FOUNDATION WALLS REPOINT Purpose of Action LEVEL 5 Photo1 Basement BRICK: OPEN JOINTS Location/Instance Basement Quantity 40 REPOINT Purpose of Action LEVEL 5 Photo1 Basement ROOF STRUCTURE VAULTS-BUNKERS Foundation Walls Slab Structure Vault/Ash Hoist Doors and Framing AUDITORIUM CAFETERIA CLASSROOMS/CORRIDORS/ADMIN SPACES Ceiling 1 - Good PB/A&W Page 20 of 40

21 Building Assessment Survey Architectural Inspection INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Ceiling ACOUSTIC TILES ON PLASTER: DAMAGED/MISSING Location/Instance Room 200 Quantity 10 Photo1 Room 200 ACOUSTIC TILES: DAMAGED/MISSING Location/Instance Main Entrance Vestibule Quantity 10 Photo1 Main Entrance Vestibule PLASTER: CRACKS/SPALLING Location/Instance Near Room 209, 200 Quantity 20 PB/A&W Page 21 of 40

22 Building Assessment Survey Architectural Inspection INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Ceiling Photo1 Near Room 209 PLASTER: CRACKS/SPALLING - ACTIVE LEAK Location/Instance Room 313 Quantity 10 Urgency of Action PRIORITY 5 Photo1 Room 313 Door(s) 5 - Poor WOOD: DETERIORATED DOOR Location/Instance Rooms 303, 109 Quantity 2 EACH MAINTENANCE Photo1 PB/A&W Page 22 of 40

23 Building Assessment Survey Architectural Inspection INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Door(s) Room 303 METAL: MISSING DOOR Location/Instance Corridor Near Rooms 102, 109, 204, 218, 310, 313, 316 Quantity 11 EACH MAINTENANCE Urgency of Action PRIORITY 5 Purpose of Action LEVEL 6 Photo1 Corridor Near Room Z Floor Finish 4 - Between Fair and Poor TERRAZZO: CRACKS Location/Instance Near Rooms 316, 207, 119 Quantity 30 Photo1 Near Room 207 Location/Instance Quantity 2,120 VINYL TILES: DETERIORATED SUBSTRATE Near Rooms 402, 202, Archive Room, Rooms 316, 208A, 200 and others PB/A&W Page 23 of 40

24 Building Assessment Survey Architectural Inspection INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Floor Finish Photo1 Near Room 402 Walls PLASTER: CRACKS/SPALLING Location/Instance Rooms 203, 103, Near Rooms 304, 303, 109 and others Quantity 90 Photo1 Near Room 304 GYPSUM BOARD: DETERIORATED Location/Instance Room 404 Quantity 10 PB/A&W Page 24 of 40

25 Building Assessment Survey Architectural Inspection INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Walls Photo1 Room 404 Specialties Classroom Locker(s) Fixed Seating GYMNASIUM INTERIOR DOOR HARDWARE INTERIOR GUARDS KITCHEN LIBRARY Instance on 1st Floor Built-in Furnishing Instance on 1st Floor Ceiling Instance on 1st Floor ACOUSTIC TILES: DAMAGED/MISSING Location/Instance Near Entrance Quantity 20 Photo1 PB/A&W Page 25 of 40

26 INTERIOR LIBRARY Ceiling Building Assessment Survey Near Entrance Door(s) Instance on 1st Floor Floor Finish Instance on 1st Floor Walls Instance on 1st Floor PLASTER: CRACKS/SPALLING Location/Instance Near Entrance Quantity 10 Photo1 LOCKER ROOM Instance on 1st Floor (28 Lockers) Alternative use Ceiling Instance on 1st Floor (28 Lockers) Door(s) Instance on 1st Floor (28 Lockers) Floor Finish Instance on 1st Floor (28 Lockers) Locker Room Lockers Near Entrance 1 - Good PB/A&W Page 26 of 40

27 Building Assessment Survey Architectural Inspection INTERIOR LOCKER ROOM Locker Room Lockers Instance on 1st Floor (28 Lockers) 3 - Fair DAMAGED UNITS Location/Instance Locker 455 Quantity 1 EACH Photo1 Locker 455 Walls Instance on 1st Floor (28 Lockers) PLASTER: CRACKS/SPALLING Location/Instance Near Windows Quantity 40 Photo1 MULTI-PURPOSE ROOM Instance on 1st Floor - East Instance on 1st Floor - Center Ceiling Instance on 1st Floor - East Near Windows PB/A&W Page 27 of 40

28 Building Assessment Survey Architectural Inspection INTERIOR MULTI-PURPOSE ROOM Ceiling ACOUSTIC TILES ON PLASTER: DAMAGED/MISSING Location/Instance Center, rtheast, West, Near Entrance Quantity 60 Photo1 Center Door(s) Instance on 1st Floor - East Instance on 1st Floor - Center Fixed Equipment Instance on 1st Floor - Center Instance on 1st Floor - East Floor Finish Instance on 1st Floor - Center 5 - Poor VINYL TILES: DETERIORATED SUBSTRATE Location/Instance Near Entrance, rth, East, West, Center Quantity 600 Photo1 PB/A&W Page 28 of 40

29 INTERIOR MULTI-PURPOSE ROOM Floor Finish Building Assessment Survey Near Entrance Sliding-folding Partition Instance on 1st Floor - East Instance on 1st Floor - Center Stage Instance on 1st Floor - East Instance on 1st Floor - Center Walls Instance on 1st Floor - Center PLASTER: CRACKS/SPALLING Location/Instance Near Entrance Quantity 20 Photo1 Window Curtains/Shades/Blinds Instance on 1st Floor - Center Instance on 1st Floor - East SCIENCE DEMO ROOM SCIENCE LAB Instance on Rooms 201, 203, 316 Alternative use Fixed Equipment Instance on Rooms 201, 203, 316 SCIENCE PREP ROOM Instance on Room 202 Alternative use Fixed Equipment Instance on Room 202 Near Entrance PB/A&W Page 29 of 40

30 Building Assessment Survey Architectural Inspection INTERIOR SCIENCE PREP ROOM Fixed Equipment SHOWER ROOM STAIRS/RAMPS: INTERIOR Do Letter Stair Signs Exist? Yes Ceiling Door(s) Partition Railings WOOD: MISSING Location/Instance Room 312 Quantity 5 L.F. Urgency of Action PRIORITY 5 Purpose of Action LEVEL 6 Photo1 Room 312 Stairs and Landings SHEET VINYL: DETERIORATED SUBSTRATE Location/Instance Room 312 Quantity 40 PB/A&W Page 30 of 40

31 INTERIOR STAIRS/RAMPS: INTERIOR Stairs and Landings Photo1 Building Assessment Survey Room 312 TERRAZZO: CRACKS Location/Instance Stairs A/4, 3, B/2, C/2, E/2 Quantity 30 Photo1 Stair A/4 Walls PLASTER: CRACKS/SPALLING Location/Instance Stair A/2 Quantity 20 Photo1 PB/A&W Page 31 of 40

32 INTERIOR STAIRS/RAMPS: INTERIOR Walls Building Assessment Survey Stair A/2 TOILET ROOMS - STAFF Ceiling PLASTER: CRACKS/SPALLING Location/Instance 3rd Floor Men Quantity 10 Photo1 3rd Floor Men Door(s) 5 - Poor WOOD: DAMAGED LOUVER Location/Instance 2nd Floor Men Quantity 1 EACH MAINTENANCE Photo1 2nd Floor Men WOOD: DETERIORATED DOOR Location/Instance Room 325 Quantity 1 PB/A&W Page 32 of 40

33 Building Assessment Survey Architectural Inspection INTERIOR TOILET ROOMS - STAFF Door(s) EACH MAINTENANCE Photo1 Room 325 Floor Finish Stalls 5 - Poor RUST - MAJOR Location/Instance 2nd Floor Men's Room Quantity 1 EACH Photo1 photo recorded Walls CERAMIC TILE: BROKEN/ MISSING Location/Instance 3rd Floor Men, 2nd Floor Men Quantity 20 Photo1 PB/A&W Page 33 of 40

34 INTERIOR TOILET ROOMS - STAFF Walls Building Assessment Survey rd Floor Men TOILET ROOMS - STUDENTS Ceiling Door(s) 5 - Poor WOOD: DAMAGED LOUVER Location/Instance Near Room 201 Quantity 1 EACH MAINTENANCE Photo1 Near Room 201 Floor Finish TERRAZZO: CRACKS Location/Instance Near Room 201 Quantity 10 Photo1 Near Room 201 Stalls PB/A&W Page 34 of 40

35 Building Assessment Survey Architectural Inspection INTERIOR TOILET ROOMS - STUDENTS Stalls Walls LIFE SAFETY F.D. HOLDING AREA STEEL STAIRS 5 - Poor MAJOR RUSTING Location/Instance Façade G, Roof 20 Quantity 40 Urgency of Action PRIORITY 4 Photo1 Façade G MINOR RUSTING Location/Instance Façade I Quantity 25 MAINTENANCE Photo1 photo recorded SITE CONTAINERIZATION 5 - Poor FENCING MISSING Location/Instance Near Parking Lot Quantity 750 INSTALL NEW PB/A&W Page 35 of 40

36 SITE CONTAINERIZATION Photo1 Building Assessment Survey Near Parking Lot CONTAINER DAMAGED Location/Instance Near Parking Lot Quantity 3 EACH Photo1 Drainage System for Asphalt Catch Basins/Manhole - Surrounded by asphalt Culverts - Asphalt Covering Drainage System for Concrete Catch Basins/Manhole - Surrounded by concrete Culverts - Concrete Covering Drainage System for Soil Catch Basins/Manhole - Surrounded by Soil Culverts - Soil Covering DRINKING FOUNTAINS FENCES Near Parking Lot 1 - Good 4 - Between Fair and Poor PB/A&W Page 36 of 40

37 SITE FENCES Location/Instance Quantity 680 WROUGHT IRON: DAMAGED/DETERIORATED Along Evergreen Avenue, Along Dekalb Avenue, Along Bushwick Avenue, Along Stockholm Street Photo1 Building Assessment Survey Along Evergreen Avenue Location/Instance Quantity 375 CONCRETE CURB: DAMAGED/DETERIORATED Along Evergreen Avenue, Along Dekalb Avenue, Along Bushwick Avenue, Along Stockholm Street Photo1 IRRIGATION SYSTEM PAVING Student n-use Gravel Exists? Asphalt Concrete Along Dekalb Avenue 1 - Good 3 - Fair CRACKS - MAJOR PB/A&W Page 37 of 40

38 Building Assessment Survey Architectural Inspection SITE PAVING Student n-use Concrete Location/Instance Along Stockholm Street, Along Dekalb Avenue Quantity 150 Photo1 Along Stockholm Street Pavers Student Use Gravel Exists? Asphalt Concrete Pavers Site Sidewalks & Walkways Asphalt Concrete Pavers DOT Sidewalk Asphalt Concrete Location/Instance Quantity Good 1 - Good 5 - Poor DAMAGED CURBS Along Evergreen Avenue, Along Dekalb Avenue, Along Bushwick Avenue, Along Stockholm Street L.F. Urgency of Action PRIORITY 4 Purpose of Action LEVEL 4 PB/A&W Page 38 of 40

39 SITE PAVING DOT Sidewalk Concrete Photo1 Building Assessment Survey Along Location/Instance Quantity 5,125 DAMAGED/DETERIORATED/MISSING SECTIONS Along Evergreen Avenue, Along Dekalb Avenue, Along Bushwick Avenue, Along Stockholm Street Urgency of Action PRIORITY 4 Purpose of Action LEVEL 4 Photo1 Pavers PLAYGROUNDS PLAYING SURFACE RETAINING WALLS Are there any Retaining Walls 6' OR higher facing public street/sidewalk? Location/Instance Quantity 10 Along Dekalb Avenue STONE: CRACKS/SPALLING - MAJOR Along Stockholm Street PB/A&W Page 39 of 40

40 SITE RETAINING WALLS Photo1 Building Assessment Survey Along Stockholm Street SEATING SITE WALLS (NOT RETAINING WALLS) STAIRS/RAMPS: EXTERIOR Railings Site Cheek/flank Walls Stairs/ramps Location/Instance Quantity 10 CAST IN PLACE CONCRETE: WORN-OUT TREAD/RISER/NOSERS Along Stockholm Street Photo1 Along Stockholm Street PB/A&W Page 40 of 40