Equipment Mounting Supports

Size: px
Start display at page:

Download "Equipment Mounting Supports"

Transcription

1 54 years of excellence

2 Table of Contents General Information Specifications Submittal Load Bearing Table years of excellence

3 General Information TEMS-1 For insulated Roof Decks with 3 cant and variable step to match deck insulation thickness. Standard step dimension ½ minimum to 2 maximum. Step dimensions over 2 available as an option. TEMS-2 For Non-insulated Roof Decks with 3 cant. TEMS-3 For All Roof Decks 54 years of excellence

4 General Information Thybar Equipment Mounting Supports are factory fabricated sheet steel structural members designed for placement on all types of roof systems and at the same time accommodates a variety of roof mounted heating, ventilating and air conditioning equipment. These units have a high load-bearing capacity attained by a system of internal bulkheads welded into position at specific intervals along the length of the rails. A continuous wood nailer covered by a removable counter flashing provides for an effective method of attaching roofing felts and assuring a watertight installation. Equipment Supports are fabricated in three basic styles designated for the following applications: 54 years of excellence

5 Specification TEMS-1 & 2 Pre-fabricated equipment mounting supports to be of prime G-90 galvanized steel construction, 18 or 14 gauge as required, meeting AS A653/653M, with welded corners and 3 cant fully mitered with seams joined by continuous welds. Supports shall be internally reinforced with bulkheads and spreaders 24 on center, factory installed 2 x 4 or 2 x 8 wood nailer and 18 gauge counter flashing. Certified load bearing data can be provided upon request. Height to be NRCA 10 above roof deck or as detailed. Equipment supports shall span a minimum of two (2) joists and not cantilever more than. Support shall be level at the top with pitch built-in when deck slopes per building specification of an inch per foot or greater, or as detailed. 54 years of excellence

6 Specification TEMS-3 Pre-fabricated equipment mounting supports to be of prime G-90 galvanized steel construction, 18 or 14 gauge as required, meeting AS A653/653M, with welded corners with seams joined by continuous welds. Supports shall be internally reinforced with bulkheads and spreaders 24 on center, have factory installed 2 x 4 or 2 x 6 wood nailer and 18 gauge counter flashing. Certified load bearing data can be provided upon request. Height to be above roof deck or as detailed. Equipment supports shall span a minimum of two (2) joists and not cantilever more than. Support shall be level at the top with pitch built-in when deck slopes 1/4 per foot or greater, or as detailed. 54 years of excellence

7 TEMS-1 for Insulated Roof Decks Submittal Standard Features: gauge galvanized steel shell, base plate and counter flashing 2. Factory installed wood nailer 3. Internal bulkhead reinforcement 4. All welded construction Provide amount of pitch, direction and minimum height, if necessary. Added Options: Unistrut Model Slope Remarks Addison Corporate Office 913 S. Kay Avenue Addison, IL Ph: (630) Fax: (630) CURB (2872) Farmers Branch Office Senlac Drive Farmers Branch, TX Ph: (972) Fax: (972) CURB (2872) Akron Office Burt Manufacturing Co. 44 E. South Street Akron, OH Ph: (330) Fax: (330) CURB (2872) Louisville Office Bunsen Way Louisville, KY Ph: (502) Fax: (502) CURB (2872) McCarran Office 711 Denmark Drive McCarran, NV Ph: (775) Fax: (775) CURB (2872) 54 years of excellence

8 TEMS-2 Non-Insulated Roof Deck & All Existing Submittal Standard Features: gauge galvanized steel shell, base plate & counter flashing 2. Factory installed wood nailer 3. Internal bulkhead reinforcement 4. All welded construction Provide amount of pitch, direction and minimum height, if necessary. Added Options: Unistrut Model Slope Remarks Addison Corporate Office 913 S. Kay Avenue Addison, IL Ph: (630) Fax: (630) CURB (2872) Farmers Branch Office Senlac Drive Farmers Branch, TX Ph: (972) Fax: (972) CURB (2872) Akron Office Burt Manufacturing Co. 44 E. South Street Akron, OH Ph: (330) Fax: (330) CURB (2872) Louisville Office Bunsen Way Louisville, KY Ph: (502) Fax: (502) CURB (2872) McCarran Office 711 Denmark Drive McCarran, NV Ph: (775) Fax: (775) CURB (2872) 54 years of excellence

9 TEMS-3 Submittal Standard Features: gauge galvanized steel shell, base plate and counter flashing 2. Factory installed wood nailer 3. Internal bulkhead reinforcement 4. All welded construction Provide amount of pitch, direction and minimum height, if necessary. Added Options: Unistrut Model Slope Remarks Addison Corporate Office 913 S. Kay Avenue Addison, IL Ph: (630) Fax: (630) CURB (2872) Farmers Branch Office Senlac Drive Farmers Branch, TX Ph: (972) Fax: (972) CURB (2872) Akron Office Burt Manufacturing Co. 44 E. South Street Akron, OH Ph: (330) Fax: (330) CURB (2872) Louisville Office Bunsen Way Louisville, KY Ph: (502) Fax: (502) CURB (2872) McCarran Office 711 Denmark Drive McCarran, NV Ph: (775) Fax: (775) CURB (2872) 54 years of excellence

10 Load Bearing Data Nailer Height Gauge TEMS-1 TEMS-2 TEMS Area IN S IN I IN Load/Ft Center Load* End Reaction Intermediate Reaction Nailer Height Gauge TEMS-1 TEMS-2 TEMS Area IN S IN I IN Load/Ft Center Load* End Reaction Intermediate Reaction * 8 Span Data was obtained from standard production samples and contains a safety factor of 2. Thybar Corporation can certify load conditions not covered above upon request. All concentrated loads are based on a minimum bearing surface width of 4 by the full width of the supports. A minimum spacing of two feet will be required between combination loads, which exceed the recommended maximum values. No load should be applied on cantilever section in excess of 6 inches in length. 54 years of excellence

11 Vibro-Mate Addison Corporate Office 913 S. Kay Avenue Addison, IL Ph: (630) Fax: (630) CURB (2872) Farmers Branch Office Senlac Drive Farmers Branch, TX Ph: (972) Fax: (972) CURB (2872) Akron Office Burt Manufacturing Co. 44 E. South Street Akron, OH Ph: (330) Fax: (330) Louisville Office Bunsen Way Louisville, KY Ph: (502) Fax: (502) CURB (2872) McCarran Office 711 Denmark Drive McCarran, NV Ph: (775) Fax: (775) CURB (2872) 54 years of excellence CURB (2872) 148