1 Installation Instrucions Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, T F

2 INDEX REFERENCES TECHNICAL DATA MEASURES INDICATIONS INSTALLATION EXTRACTION TOOL RGB CONNECTIONS MONOCOLOR CONNECTIONS SAFETY PRECAUTIONS

3 PRODUCT CODES Options The standard version in RGB model is delivered with DMX. Also available with DALI control. Ground Liner 1000 x 33 mm. Opal white /C02 Ground Liner 1000 x 33 mm. Opal warm white /C22 Ground Liner 1000 x 33 mm. Opal blue /C09 Ground Liner 1000 x 33 mm. Opal RGB /C11 Ground Liner 500 x 33 mm. Opal white /C02 Ground Liner 500 x 33 mm. Opal warm white /C22 Ground Liner 500 x 33 mm. Opal blue /C09 Ground Liner 500 x 33 mm. Opal RGB /C11 * Ground Liner 250 x 33 mm. Opal white /C02 * Ground Liner 250 x 33 mm. Opal warm white /C22 * Ground Liner 250 x 33 mm. Opal blue /C09 * Ground Liner 250 mm. only suitable for end of the line Recessed box 1000 mm. Ground Liner Silver /C12 Recessed box 500 mm. Ground Liner Silver /C12 Recessed box 250 mm. Ground Liner Silver /C12

4 TECHNICAL DATA MECHANICAL SPECIFICATIONS Version 250 mm. 500 mm mm. *Measures 130 x 75 x 250 mm. 130 x 75 x 500 mm. 130 x 75 x 1000 mm. Weight Lens Housing Recessed box Pressure load Protection class Luminaire Recessed box 0,51 kg. 1,02 kg. 2,03 kg. 0,68 kg. 1,23 kg. 2,35 kg. EPOXY Resin 20 micras aluminium 30 kn IP66/68 ELECTRICAL SPECIFICATIONS Impact resistance Temperature range * Recessed box included Input voltage Protection class Control type Monocolor RGB IK10-30 C a +70 C -22 F to +158 F 24V DC III PWM / CA (Common anode) DMX512-A / DALI 250 mm. 500 mm mm. LED quantity Monocolor Power consumption 3,84 W 7,68 W 15,36 W LED quantity N.A RGB Power consumption N.A. 8,7 W 17,3 W N.A. Not available

5 DIMENSIONS Inner Body 30 mm. (1,18 in) 1000 / 500 / 250 mm. (39,4 / 19,7 / 9,85 in) 43 mm. (1,69 in) Outer Body 35 mm. (1,38 in) 1000 / 500 / 250 mm. (39,4 / 19,7 / 9,85 in) 125 mm. (4,92 in) 75 mm. (2,95 in)

6 INDICATIONS READ BEFORE INSTALLING THE PRODUCT! Never use the product as concrete expansion joint. Must be taken into consideration the concrete expansions. Leave separation of 1 mm as minimum between two luminaires every two meters of installed product. Do not take out the foam joint stuck to the box, it is needed to absorb possible material expansions. For concrete installation, shoetld be used a covering over the concrete in order to improve the protection against external chemical agents. Leave the 20 cm of drainage is under installer s responsibility. Not leaving it, may cause the damage of the luminaire and consequent loss of warranty.

7 INSTALLATION Place it to avoid entrance of dirt NOT INCLUDED

8 INSTALLATION 1 2 3

9 INSTALLATION Pour the concrete carefully around the luminaires Remove cover

10 INSTALLATION Concrete detail 20 cm MINIMUM DRAINAGE 5mm FILL UP WITH CONCRETE UP TO 5mm OVER THE BOX LEVEL Luminaire place Luminaire position GLETL.IMT-152.V1.11.

11 INSTALLATION Once the luminaire has been placed, the lateral sides must be sealed with BOSTIK POLIURETANE for OUTDOOR applications

12 INSTALLATION Next Luminaire Next Luminaire GLETL.IMT-152.V1.13.

13 EXTRACTION TOOL Centric extraction End extraction

14 GRUPO MCI DMX CONTROLLER GRUPO MCI DMX CONTROLLER GROUND LINER ETL RGB CONNECTIONS This connection to be made inside outer body M M This connection to be made inside outer body This connection to be made inside outer body A DMX 512-A more than 5 luminaires DMX Amplifier NOTE: All wiring outside of outer bodies must be run thru conduit! DMX Controller Remote power supply to be connected to fixtures inside a nema style (or equal) enclosure (by others), using appropriate wirenuts. PSU 24V DC - 320W DATA M DMX 3 Output 4 DMX Output 1 B DMX 512-A up to 5 luminaires DMX Controller Maximum 5 luminaires of 1m. per DMX output with PSU 24V DC - 320W Maximum 100 meters from controller to first luminaire Maximum 100 meters from amplifier to last luminaire 24+ (White) GND- (Black) DMX+ (Brown) DMX- (Blue) 24V DC Maximum 5 luminaires of 1m. per DMX controller with PSU 24V DC - 150W Maximum 100 meters from controller to first luminaire Follow connection diagram type B for DALI installations

15 MONOCOLOR CONNECTIONS This connection to be made inside outer body M M This connection to be made inside outer body This connection to be made inside outer body M A MONOCOLOR NO DIMMABLE PSU 24V DC - 320W 2 3 Line NOTE: All wiring outside of outer bodies must be run thru conduit! Remote power supply to be connected to fixtures inside a nema style (or equal) enclosure (by others), using appropriate wirenuts. Maximum 5 luminaires of 1 meter each line connected with PSU 24V DC - 320W (15m.) Maximum 5 meters from power supply to first luminaire POWER + CONTROL CONTROLLER 3 2 B Lineardrive Dimmer Basic DIMMABLE MONOCOLOR PSU 24V DC - 320W PSU 24V DC - 320W Line 2 3 Remote power supplies to be connected to fixtures inside a nema style (or equal) enclosure (by others), using appropriate wirenuts. Lineardrive 720 Dimmer Basic Maximum 5 luminaires of 1 meter (15 meters) per line connected to lineardrive 720D (PSU 24V DC - 320W) Maximum 5 meters from power supply to first luminaire Maximum 3 lines of 5 luminaires of 1 meter each line in parallel connection to PSU 24V DC - 320W (15m.) Each line must have one dimmer basic Maximum 5 meters from power supply to first luminaire

16 + Dali IN Dali IN Dali OUT Dali OUT DMX + DMX - DMX shield LEDSync + LEDSync - LEDSync shield - GROUND LINER ETL MONOCOLOR CONNECTIONS Lineardrive 720D DMX/DALI/0-10V 24V DC Power Supply 24 V DC 320 W M max. 5 uds. x1m max. 5 uds. x1m Group 1 GND 1 Steady Light LINEARdrive 720D Group 2 GND 2 Group 3 GND 3 Group 4 GND 4 Next line PWM (Blue) GND- (Black) 24+ (White) 24+ (Brown) V DC max. 5 uds. x1m Power Supply 24 V DC 320 W + - max. 5 uds. x1m PWM (Blue) GND- (Black) 24+ (White) 24+ (Brown) V DC Next line

17 SAFETY PRECAUTIONS Use as directed This product serves exclusively lighting purposes and may: Expose to strong mechanical loads or strong contamination. Only be installed and operated after a condition inspection if the product is dirty or has been moistened through storage. Not be modified or converted. If these points named above are not adhered to, a short circuit or electrical shock may occur! Installation The complete installation must be done by an electrical expert or a specialized maintenance team, who is familiar with valid directives. Attention: Switch off power of the mains supply or respectively of the connection lead before doing any works. Use only parts, which are supplied with the product or are described as accessories! Otherwise the product or the installation might not be sufficiently safe! Indication for the installer: In case you do not install a completely supplied system (with transformer), you are considered a manufacturer by the low-voltage directive. In this case you are required to ensure the conformity of the whole system and declare it by attaching the CE-sign. Installation place Make sure that the product is mounted on a stable, even and tilt-fixed background. Note the minimum distances in the ceiling. Attention: Do not cover the product, especially not with insetlating materials. Operation - Information for the user Operate the product only if it is working correctly. Switch off the product with a malfunction immediately and operate it again only after examination by an electrical specialist. This is the case, when: Visible damages appear. The product does not work. Smoke, steam or crackling sounds appear. An overheating is recognisable. Repairs of the product or work on mains voltage-prominent sections may only be carried out by qualified electricians. Attention: Exists mortal danger from an electric shock! How to avoid failure and fire risk Do not cover the product - provide free air circetlation! Do not hang or fasten anything on the product, especially no decoration. Never let children play unsupervised with electric products! Children can not always estimate dangers in dealing with electric energy correctly. Disconnect the product from power, before you Clean or maintain the product. Do any works on the product or its components (electric expert).

18 Ground Liner ETL IMT-152 v.01 Designplan Lighting, Inc., 79 Trenton Ave., Frenchtown NJ, T F