1 C/TC 88 - Thermal insulating materials and Standard reference CR 245: : : : : : : :1996/AC: 1603: :1996/A1: 1603:1996/AC: 1604: :1996/A1: 1604:1996/AC: 1605: :1996/A1: 1605:1996/AC: 1606:1996 Title Thermal insulation - Classification of building materials according to their thermal insulation properties Determination of length and width Determination of thickness Determination of squareness Determination of flatness Determination of compression behaviour Determination of the apparent density Determination of the apparent density laboratory conditions (23 C/50 % relative humidity) laboratory conditions (23 C/50 % relative humidity) laboratory conditions (23 C/50% relative humidity) Directive

2 1606:1996/A1: 1606:1996/AC: 1607: :1996/AC: 1608: :1996/AC: 1609: :1996/A1: 1609:1996/AC: ISO 9229: : 12086: 12087: 12087:/A1 : 12088: 12089: 12090: 12091: 12429: : :1998/A1 Determination of tensile strength perpendicular to faces Determination of tensile strength perpendicular to faces Determination of tensile strength parallel to faces Determination of tensile strength parallel to faces Determination of short term water absorption by partial immersion Determination of dimensional short term water absorption by partial immersion Determination of short term water absorption by partial immersion Thermal insulation - Vocabulary (ISO 9229:2007) Determination of linear dimensions of test specimens Determination of water vapour transmission properties Determination of long term water absorption by immersion Determination of long term water absorption by immersion Determination of long term water absorption by diffusion Determination of bending behaviour Determination of shear behaviour Determination of freeze-thaw resistance Conditioning to moisture equilibrium under specified temperature and humidity conditions Determination of behaviour under point load Determination of behaviour under point load

3 : 12431: :1998/A1 : 13162: : : : : : : : : :2008 Determination of thickness for floating floor insulating Determination of thickness for floating floor insulating Thermal insulation for buildings - Factory made mineral wool (MW) - of expanded polystyrene (EPS) - of extruded polystyrene foam (XPS) - Thermal insulation for buildings - Factory made rigid polyurethane foam (PUR) - of phenolic foam (PF) - Thermal insulation for buildings - Factory made cellular glass (CG) - Thermal insulation for buildings - Factory made wood wool (WW) - of expanded perlite (EPB) - of expanded cork (ICB) - Thermal insulating for buildings - Factory made wood fibre (WF) :2008 Thermal insulating - Evaluation of conformity 13467: : : :2001 installations - Determination of dimensions, squareness and linearity of preformed pipe insulation installations - Determination of trace quantities of water soluble chloride, fluoride, silicate, sodium ions and ph installations - Determination of water vapour transmission properties of preformed pipe insulation installations - Determination of the apparent density of preformed pipe insulation 13471:2001 installations - Determination of the coefficient of thermal expansion 13472: : :2002 installations - Determination of short term water absorption by partial immersion of preformed pipe insulation Determination of the tensile bond strength of the adhesive and of the base coat to the thermal insulation material Determination of the pull-off resistance of external thermal insulation composite systems (ETICS)(foam block test)

4 13496: : : : : : : /AC: : : : : : : :2009 Determination of the mechanical properties of glass fibre meshes Determination of the resistance to impact of external thermal insulation composite systems (ETICS) Determination of the resistance to penetration of external thermal insulation composite systems (ETICS) Thermal insulation for buildings - External thermal insulation composite systems (ETICS) based on expanded polystyrene - Thermal insulation for buildings - External thermal insulation composite systems (ETICS) based on mineral wool - Determination of behaviour under cyclic loading Thermal insulating materials for building applications - Determination of organic content Thermal insulation for buildings - In-situ formed expanded clay lightweight aggregate - Part 1: for the loose-fill Thermal insulation - In-situ formed expanded clay lightweight aggregate - Part 1: for the loosefill Thermal insulation for buildings - In-situ formed loose-fill mineral wool (MW) - Part 1: for the loose-fill Thermal insulation for buildings - In-situ formed loose-fill mineral wool (MW) - Part 2: for the installed installations - Factory made mineral wool (MW) - installations - Factory made flexible elastomeric foam (FEF) - installations - Factory made cellular glass (CG) - installations - Factory made calcium silicate (CS) - installations - Factory made extruded polystyrene foam (XPS) - installations - Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) - installations - Factory made of expanded polystyrene (EPS) :2009

5 14314: : : :2005 installations - Factory made polyethylene foam (PEF) - installations - Factory made phenolic foam (PF) - insulation formed from expanded perlite (EP) - Part 1: for bonded and loose-fill Thermal insulating for buildings - In-situ thermal insulation formed from expanded perlite (EP) - Part 2: for the installed insulation formed from exfoliated vermiculite (EV) - Part 1: for bonded and loose-fill before installation insulation formed from exfoliated vermiculite (EV) - Part 2: for the installed installations - Determination of maximum service temperature 14707:2005+A1 :2007 installations - Determination of maximum service temperature for preformed pipe insulation 14933: : :2009 C/TR 15985:2010 Thermal insulation and light weight fill for civil engineering applications - Factory made of expanded polystyrene (EPS) - Thermal insulation and light weight fill for civil engineering applications - Factory made of extruded polystyrene foam (XPS) - installations - In-situ thermal insulation formed from expanded perlite (EP) - Part 1: for bonded and loose-fill installations - In-situ thermal insulation formed from expanded perlite (EP) - Part 2: for the installed installations - In-situ thermal insulation formed from exfoliated vermiculite (EV) - Part 1: for bonded and loose-fill installations - In-situ thermal insulation formed from exfoliated vermiculite (EV) - Part 2: for the installed Thermal insulation - Instructions for mounting and fixing for reaction to fire testing - Factory made Thermal insulating - Factory made of expanded polystyrene (EPS) - Voluntary certification of the raw material