WD66 The Standard Wood Framed Folding System

Size: px
Start display at page:

Download "WD66 The Standard Wood Framed Folding System"

Transcription

1 INTRODUCTION WD66 WD66 The Standard Wood Framed Folding System Weather Resistant Engineered to provide high weather resistance and structural performance. Excellent results were achieved with independent testing per AAMA/WDMA /CSA 100/I.S.2/ A440, NAFS North American Fenestration Standard. See Performance Testing Results pages. For benefits of all NanaWall systems, see the General Introduction section. For features common to wood folding systems, see the Wood Folding Systems Introduction. NFRC-Approved Thermal Performance The WD66 has been rated, certified and labeled in accordance with NFRC 100 and 200; see the Performance and Testing Results section for more details. 1 1/8 (28 mm) and 1 1/2 (38 mm) triple glazing available. Energy Star values can be met with selected glazing. Florida Approval The WD66 is Florida statewide approved with Product Approval number FL This information with limitations can be viewed at Life Cycle Performance The WD66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. Option of Top Hung (WD66/o) or Floor Supported System (WD66/u) The standard system is top hung, where the main weight is carried by the head track. The bottom track is a guide. The floor supported system is recommended for applications where the vertical load bearing capability of the header is a concern. The main weight is carried by the floor track. The upper track is merely a guide. Acoustical Performance A five panel WD66 unit has been tested by an independent acoustic lab for acoustical performance. The WD66 with STC 38 laminated glass achieved STC and Rw values of 37. 1

2 TECHNICAL DESCRIPTION WD66 General Description The WD66 is the standard commercial and/or residential folding or paired-panel wood framed system designed to provide an opening glass wall or storefront for widths up to 39 (12 m); see Maximum Size Chart. It is available in various configurations utilizing one to twelve panels; see elevation drawings. The option exists for a swing entry/exit panel(s). Units can be either inward-opening or outward-opening; see section drawings. Frame and Panels The three-layer, cross grained, solid wood panel frame thickness is 2 5/8 (66 mm) or 3 1/16 (78 mm); see various frame profiles in section drawings. The aluminum head jamb of the WD66/o system is clad with matching wood fascia pieces on both sides. Standard woods are European Pine, Douglas Fir or Meranti. Other woods are also available. Frames and panels have a sanding sealer or a base coat applied to be field finished by others; see Wood Finish Options in the General introduction. Panels are preassembled. All pins and screws to assemble the frame are provided. The Raised Sill (higher weather performance sill), thermally broken aluminum with 3/4 (18.5 mm) wide polyamide plastic, and various flush sills are available in a clear or dark bronze anodized finish. Glazing Units can be supplied glazed with double insulating Low-E safety glass, clear double insulating safety, 1 1/8 (28 mm) and 1 1/2 (38 mm) triple insulating Low-E safety, 1/4 (6 mm) single tempered or laminated, other high performing safety glass such as Heat Mirror, acoustic, special tint, etc., or other glass on request. Weatherstripping All weatherstripping consisting of EPDM or brush seals is provided for sealing between panels and between panels and frames; see section drawings. Sliding/Folding Hardware For sliding and folding of each pair of panels, for the WD66/o top hung system, a load-bearing, upper-running carriage and a lower-running guide carriage is attached between the two panels (shown in the section drawings). The double pair, twin-tandem, upper-running carriage is constructed to ensure even distribution of pressure on all four rollers. For the WD66/u floor supported system, a floor supported, lower running carriage and an upper running carriage as a guide is attached between the panels. Rollers have sealed bearings and are coated with toughened Polyamide to ensure sound-free running and optimal resistance to extreme temperature. Two to five patented clear or dark bronze anodized hinges per connection are provided to connect panels together and to connect panels to the frame. Locking Hardware and Handle Options For each pair of folding panels (except for the pair to be opened first in a unit with no swing panel), provided is two point locking hardware consisting of top and bottom Polyamide capped locking rods operated by a 180º turn of a flat handle on the inside only. If there is a swing panel, there are the following hardware options on the primary swing panel: 1. Multi-point Locking. Consisting of lever handles on both sides, a lockset, lockable latch, deadbolt and rods at the top and the bottom. After turn of key or thumbturn, depression of handles withdraws latch, lifting of handles engages rods and turn of key or thumbturn engages deadbolt and locks. For a unit with a secondary swing panel, available are matching dummy lever handles on both sides and a concealed flush bolt that operates the rods at the top and the bottom. Available with profile cylinder or with SFIC adapter. 2. Deadbolt Lock. Consisting of push/pull handles on both sides with deadbolt(s) operated by a lockset. Turn of key or thumb turn operates lock. Available is a lockset option of having key operation on both sides. To keep the panel closed, a door closer should be field installed, but please note that a door closer can only be installed for a swing panel that is attached to the side jamb. 3. No Hardware. For panic hardware to be installed by others, the main entry panel can be supplied with no locking hardware. 2

3 TECHNICAL DESCRIPTION WD66 For a unit with no swing panel, on the folding pair to be opened first, provided is two point locking hardware consisting of top and bottom Polyamide capped locking rods operated by a 180º turn of an L-shaped handle for an inward opening unit and a flat handle for an outward opening unit on the inside. In both cases, there will be a flat handle on the outside. Lockable with a lockset. Turn of key or thumb turn operates lock. Please note that for an outward opening unit, locking from the inside will need to be with a key that may not meet egress requirements. For a unit where locking/handles on the inside only is desired, like in window applications, on all swing panels or pair of folding panels to be opened first, provided is two point locking with a flat handle on the inside only. Handle Finish Schemes: Standard Stainless steel lever, flat, and L-shaped handles in brushed satin or black titanium finish. Push/pull handles are in brushed stainless steel. Optional Brass lever handles in oil rubbed brass or satin nickel, and flat handles powdercoated dark brown or silver gray. 3

4 TESTING RESULTS WD66 HIGHER WEATHER PERFORMANCE RAISED SILL Higher Weather Performance (Raised) Sill WD66 TYPE OF TEST INWARD OPENING UNITS OUTWARD OPENING UNITS Air Infiltration ASTM E-283, cfm/ft 1.57 psf (75 Pa): 0.08 (0.27 exfiltration) 6.24 psf (300 Pa): 1.57 psf (75 Pa): 0.04 (0.04 exfiltration) 6.24 psf (300 Pa): 0.18 Water Penetration * ASTM E 331 and ASTM E-547 No uncontrolled water 7.5 psf (360 Pa) DESIGN PRESSURE No uncontrolled water 7.5 psf (360 Pa) DESIGN PRESSURE Structural Load Deflection ASTM E-330: pass See design windload charts for other sized panels Note that the structural test pressures were 50% higher than the design pressures psf (2000 Pa) 52.5 psf (2520 Pa) Class SP-PG40, Panel size - 3 x 8 (915 mm x 2471 mm) 52.5 psf (2520 Pa) 41.5 psf (2000 Pa) Class SP-PG40, Panel size - 3 x 8 (915 mm x 2471 mm) Life Cycle Performance The WD66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. European CE Mark The WD66 is CE Mark Certfied Forced Entry Resistance In accordance with AAMA-1304 (1330 N (300 lbf) point load) requirements Acoustical Performance The WD66 system has been tested by an independent acoustic lab for acoustical performance. the WD66 with STC 38 laminated glass achieved STC and Rw values of 37. Excerpts of results of 9 7 W x 8 6 H three panel unit (3L and 3R configurations) with Higher Weather Performance (Raised) sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in april 2013 per AAMA/WDMA/CSA 101/I.S.2/A440, NAFS North American Fenestration Standard. Excerpts of results of a unit tested by Nusing Mobile Trennwandtechnile, Munster, Germany, an independent testing laboratory in August For Canada, tested to NAFS-08 or equivalent and CSA A (with weep holes in sill by others to drain standing water in sill channels). Water rating may not be applicable for configuration not tested, especially even panels and even panels configurations. * 4

5 TESTING RESULTS WD66 HIGHER WEATHER PERFORMANCE RAISED SILL Higher Weather Performance (Raised) Sill WD66 Rated, certified and labeled in accordance with NFRC Thermal Performance (Top-hung units) INWARD OPENING UNITS 66 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Clear (air filled) Double IG Standard Low E (argon filled) Double IG Standard Low E (air filled) _ Double IG Low E Alternate (argon filled) Double IG Low E Alternate (air filled) ,43 Triple IG Low E x 2 (argon filled) /8 (28 mm) Triple IG Low E x 2 (air filled) /8 (28 mm) NOTES NFRC simulated U factors of units with a horizontal mullion will have values of.01 to.02 higher than units with no horizontal mullion. Please contact NanaWall for details. SHGC = Solar Heat Gain Coefficient VT = Visible Transmittance 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <.25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) Meets SHGC energy Star Qualification criteria for north/north central zones only. Call NanaWall for U-Factor & SHGC for other glass types 5

6 TESTING RESULTS WD66 HIGHER WEATHER PERFORMANCE RAISED SILL Higher Weather Performance (Raised) Sill WD66 Rated, certified and labeled in accordance with NFRC Thermal Performance (Floor supported units) INWARD OPENING UNITS 66 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Clear (air filled) Double IG Low E Standard (argon filled) Double IG Low E Standard (air filled) _ Double IG Low E Alternate (argon filled) Double IG Low E Alternate (air filled) ,43 Triple IG Low E x 2 (argon filled) /8 (28 mm) Triple IG Low E x 2 (air filled) /8 (28 mm) NOTES NFRC simulated U factors of units with a horizontal mullion will have values of.01 to.02 higher than units with no horizontal mullion. Please contact NanaWall for details. SHGC = Solar Heat Gain Coefficient VT = Visible Transmittance 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <.25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) Meets SHGC energy Star Qualification criteria for north/north central zones only. Call NanaWall for U-Factor & SHGC for other glass types 6

7 TESTING RESULTS WD66 HIGHER WEATHER PERFORMANCE RAISED SILL Higher Weather Performance (Raised) Sill WD66 Rated, certified and labeled in accordance with NFRC Thermal Performance (Floor supported units) INWARD OPENING UNITS 78 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Low E Standard (argon filled) /8 (28 mm) Double IG Low E Standard (air filled) /8 (28 mm) Triple IG Low E (argon filled) /16 (38 mm) Triple IG Low E Alternate (air filled) /16 (38 mm) NOTES NFRC simulated U factors of units with a horizontal mullion will have values of.01 to.02 higher than units with no horizontal mullion. Please contact NanaWall for details. SHGC = Solar Heat Gain Coefficient VT = Visible Transmittance 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <.25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) Meets SHGC energy Star Qualification criteria for north/north central zones only. Call NanaWall for U-Factor & SHGC for other glass types 7

8 TESTING RESULTS WD66 LOW PROFILE SADDLE SILL Low Profile Saddle Sill WD66 TYPE OF TEST INWARD OPENING UNITS OUTWARD OPENING UNITS Air Infiltration ASTM E-283,cfm/ft 2 Water Penetration ASTM E-547 and 1.57 psf (75 Pa): 0.17 (0.17 exfiltration) 6.24 psf (300 Pa): 1.57 psf (75 Pa): 0.17 (0.05 exfiltration) 6.24 psf (300 Pa): 0.31 Low Profile Saddle Sill (top hung system - internally tested and using results for WA67 independent testing with saddle sill) No uncontrolled water 5.43 psf (250 Pa) Subject to the following additional adaptations of the sill in the field by others: 1. Remove the gaskets covering the inner channel. 2. Drill weep holes through the bottom of this channel (about one 3/8 diameter weep hole per panel). 3. Drill weep holes through the bottom of the sill or lower front face of the sill to drain water collected to a lower point (about one 3/8 weep hole per panel, or equivalent circular holes). Please note that due to varying site requirements and conditions, these sills will not be prepared for drainage by Nana Wall Systems, Inc. if this drainage system is desired, we recommend that a qualified professional construct this system on the project site strictly in accordance with nanawall instructions with good waterproofing techniques. if drain connections are not made or are not possible, unit may leak with wind driven rain. DESIGN PRESSURE DESIGN PRESSURE Positive Negative Positive Negative Structural Load Deflection ASTM E-330: pass See design windload charts for other sized 45 psf ( psf (2630 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) (weep holes by 55 psf ( psf (2160 Pa) Class SP-PG30, Panel size - 3 x 8 (915 mm x 2461 mm) (weep holes by others) Forced Entry Resistance in accordance with AAMA-1304 (1330N (300 lb) point load) Life Cycle Performance The WA66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. European CE Mark WD66 is CE Mark Certified Excerpts of results of 9 7 W x 8 6 H three panel unit with panels folding to one side with with Flush Sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in April 2013 per AAMA/WDMA/CSA 101/I.S.2/A440, NAFS-North American Fenestration Standard. Inswing unit not tested. Results based on deduction from outswing unit test results. For Canada, tested to NAFS-08 or equivalent and CSA A (with weepholes in sill by others). 8

9 TESTING RESULTS WD66 LOW PROFILE SADDLE SILL Low Profile Saddle Sill WD66 Rated, certified and labeled in accordance with NFRC Thermal Performance (Top-hung units) INWARD OPENING UNITS 66 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Clear (air filled) Double IG Standard Low E (argon filled) Double IG Standard Low E (air filled) Double IG Alternate Low E (argon filled) Double IG Alternate Low E (air filled) Triple IG Low E x 2 (argon filled) /8 (28 mm) Triple IG Low E x 2 (air filled) /8 (28 mm)

10 TESTING RESULTS WD66 LOW PROFILE SADDLE SILL Low Profile Saddle Sill WD66 Rated, certified and labeled in accordance with NFRC Thermal Performance (Floor supported units) INWARD OPENING UNITS 66 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Clear (air filled) Double IG Standard Low E (argon filled) Double IG Standard Low E (air filled) Double IG Alternate Low E (argon filled) Double IG Alternate Low E (air filled) Triple IG Low E x 2 (argon filled) /8 (28 mm) Triple IG Low E x 2 (air filled) /8 (28 mm) Rated, certified and labeled in accordance with NFRC Thermal Performance (Floor supported units) INWARD OPENING UNITS 78 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Low E Standard (argon filled) /8 (28 mm) Double IG Low E Standard (air filled) /8 (28 mm) Triple IG Low E Alternate (argon filled) /16 (38 mm) Triple IG Low E Alternate (air filled) /16 (38 mm)

11 TESTING RESULTS WD66 STANDARD FLUSH SILL Standard Flush Sill WD66 TYPE OF TEST INWARD OPENING UNITS OUTWARD OPENING UNITS Air Infiltration ASTM E-283,cfm/ft 1.57 psf (75 Pa): 0.17 (0.17 exfiltration) 6.24 psf (300 Pa): 1.57 psf (75 Pa): 0.17 (0.05 exfiltration) 6.24 psf (300 Pa): 0.31 Water Penetration ASTM E-547 and E-331 Standard Flush Sill (similar conditions with low profile saddle sill with weepage from middle channel only) No uncontrolled water 2.92 psf (140 Pa) (similar conditions for standard flush sill) Subject to the following adaptations of the sill in the field by others: 1. Drill weep holes through the outer bottom wall in the middle channel 3/8 weep hole per panel). 2. Drill weep holes through the lower front face of the sill to drain water collected to a lower point (3/8 weep hole per panel). Please note that due to varying site requirements and conditions, these sills will not be prepared for drainage by Nana Wall Systems, Inc. if this drainage system is desired, we recommend that a qualified professional construct this system on the project site strictly in accordance with nanawall instructions with good waterproofing techniques. if drain connections are not made or are not possible, unit may leak with wind driven rain. DESIGN PRESSURE DESIGN PRESSURE Structural Load Deflection ASTM E-330: pass See design windload charts for other sized panels 45 psf (2160 Pa) 55 psf (2630 Pa) 55 psf (2630 Pa) 45 psf (2160 Pa) Forced Entry Resistance in accordance with AAMA-1304 (1330N (300 lb) point load) Life Cycle Performance The WA66 meets the German DIN EN 1191/12400 Classification, where a unit is tested after 20,000 opening and closing cycles and is still functional. European CE Mark WD66 is CE Mark Certified Excerpts of results of 9 7 W x 8 6 H three panel unit (3R configuration) with Flush Sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in April 2013 per AAMA/WDMA/CSA101/I.S.2/A440, NAFS-North American Fenestration Standard. Inswing unit not tested. Results based on deduction from outswing unit test results. 11

12 TESTING RESULTS WD66 STANDARD FLUSH SILL Standard Flush Sill WD66 Rated, certified and labeled in accordance with NFRC Thermal Performance (Top-hung units) INWARD OPENING UNITS 66 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Clear (air filled) _ Double IG Standard Low E (argon filled) Double IG Standard Low E (air filled) _ Double IG Alternate Low E (argon filled) Double IG Alternate Low E (air filled) Triple IG Low E x 2 (argon filled) /8 (28 mm) Triple IG Low E x 2 (air filled) /8 (28 mm) NOTES NFRC simulated u factors of units with a horizontal mullion will have values of about.01 to.02 higher than units with no horizontal mullion. Please contact nanawall for details. SHGC = Solar Heat Gain Coefficient VT = Visible Transmittance 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <.25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) Meets SHGC Energy Star Qualification criteria for North/North Central zones only. Call NanaWall for U-Factor & SHGC for other glass types 12

13 TESTING RESULTS WD66 Standard Flush Sill WD66 STANDARD FLUSH SILL Rated, certified and labeled in accordance with NFRC Thermal Performance (Floor supported units) INWARD OPENING UNITS 66 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Clear (air filled) Double IG Standard Low E (argon filled) Double IG Standard Low E (air filled) Double IG Alternate Low E (argon filled) Double IG Alternate Low E (air filled) Triple IG Low E x 2 (argon filled) /8 (28 mm) Triple IG Low E x 2 (air filled) /8 (28 mm) Rated, certified and labeled in accordance with NFRC Thermal Performance (Floor supported units) INWARD OPENING UNITS 78 MM PROFILE OUTWARD OPENING UNITS TYPE OF GLASS (1 LITE) CENTER OF GLASS IG GLASS THICKNESS UNIT SHGC VT ENERGY 2015 STAR UNIT SHGC VT ENERGY 2015 STAR Double IG Low E Standard (argon filled) /8 (28 mm) Double IG Low E Standard (air filled) /8 (28 mm) Triple IG Low E (argon filled) /16 (38 mm) Triple IG Low E (air filled) /16 (38 mm) NOTES NFRC simulated u factors of units with a horizontal mullion will have values of about.01 to.02 higher than units with no horizontal mullion. Please contact nanawall for details. SHGC = Solar Heat Gain Coefficient VT = Visible Transmittance 2015 Energy Star Qualification Criteria: U-Factor for doors in all climate zones <.30, SHGC <.25 in South/South Central zones and <.40 in North/North Central zones. (For guidance only. NanaWall is not a participant of the Energy Star program.) Meets SHGC Energy Star Qualification criteria for North/North Central zones only. Call NanaWall for U-Factor & SHGC for other glass types 13

14 MAXIMUM SIZE CHART WD66 FRAME HEIGHT OF UNIT NUMBER OF PANELS IN UNIT 9 10 (3000) 9 6 (2900) 9 2 (2800) 8 10 (2700) 8 6 (2600) 8 2 (2500) 7 10 (2400) 7 6 (2300) 7 2 (2200) 6'10" (2100) and below '11" (600) 3'11" (1200 5"10" (1800) 7'10" (2400) 9'10" (3000) 11'9" (3600) 13'10" (4200) 15'8" (4800) 17'9" (5400) 19'8" (6000) 21'7" (6600) 23'6" (7200) NOTE: English dimensions are approximate. Dimensions in parenthesis are in millimeters. 2 3 (700) 4 7 (1400) 6 10 (2100) 9 2 (2800) 11 5 (3500) (4200) 16 (4900) 18 4 (5600) 20 7 (6300) (7000) 25 1 (7700) 27 4 (8400) 2 7 (800) 5 3 (1600) 7 10 (2400) 10 6 (3200) 13 1 (4000) 15 8 (4800) 18 4 (5600) (6400) 23 6 (7200) 26 1 (8000) 28 8 (8800) 31 5 (9600) FRAME WIDTH OF UNIT A 2 11 (900) 5 10 (1800) 8 10 (2700) 11 9 (3600) 14 9 (4500) 17 8 (5400) 20 7 (6300) 23 6 (7200) 26 5 (8100) 29 4 (9000) 32 5 (9900) (10800) B 3 3 (1000) 6 6 (2000) A & B 9 10 (3000) 13 1 (4000) 16 4 (5000) 19 8 (6000) (7000) 26 1 (8000) 29 4 (9000) 32 9 (10000) 36 1" (11000) 39 4" (12000) With 2 5/8" (66 mm) thick profile For Single Glass, Double and 1 1/8" (28 mm) Triple Insulated Glass - both top hung and floor supported systems Up to twelve panels are possible in a unit. Any custom panel size is possible up to the maximum size shown. Solid dark line on chart indicates maximum frame height possible for a given maximum frame width For heights above 8 4 (2550 mm), panels have to be stiffened with a horizontal mullion. (If no horizontal mullion is desired, please see size chart for 3 1/16" (78 mm) on page 7) A. For configurations hinged to a side jamb combined with a pair(s) of folding panels or for configurations with a pair(s) of folding panels only includes models 1L, 1R, 1L1R, 2L, 2R, 1L2R, 2L1R, 2L2R, 4L, 4R, 1L4R, 4L1R, 2L4R, 4L2R, 6L, 6R, 1L6R, 6L1R, 4L4R, 2L6R, 6L2R, 4L6R, 6L4R, 6L6R. B. For all configurations. The maximum size limits are based on the maximum weight of a panel that has a net glass thickness of 5/16 (8 mm) or 5/32 (4 mm) for each glass pane. For thicker glass this maximum size limit chart will not apply. For configurations with only even number of panels stacking to each side, the minimum width of each panel is 2'3" (700 mm). 14

15 MAXIMUM SIZE CHART WD66 FRAME HEIGHT OF UNIT NUMBER OF PANELS IN UNIT 9 10 (3000) 9 6 (2900) 9 2 (2800) 8 10 (2700) 8 6 (2600) 8 2 (2500) 7 10 (2400) 7 6 (2300) 7 2 (2200) 6'10" (2100) and less '11" (600) 3'11" (1200 5"10" (1800) 7'10" (2400) 9'10" (3000) 11'9" (3600) 13'10" (4200) 15'8" (4800) 17'9" (5400) 19'8" (6000) 21'7" (6600) 23'6" (7200) NOTE: English dimensions are approximate. Dimensions in parenthesis are in millimeters. 2 3 (700) 4 7 (1400) 6 10 (2100) 9 2 (2800) 11 5 (3500) (4200) 16 (4900) 18 4 (5600) 20 7 (6300) (7000) 25 1 (7700) 27 4 (8400) 2 7 (800) 5 3 (1600) 7 10 (2400) 10 6 (3200) 13 1 (4000) 15 8 (4800) 18 4 (5600) (6400) 23 6 (7200) 26 1 (8000) 28 8 (8800) 31 5 (9600) A B 2 11 (900) 5 10 (1800) 8 10 (2700) 11 9 (3600) 14 9 (4500) 17 8 (5400) 20 7 (6300) 23 6 (7200) 26 5 (8100) 29 4 (9000) 32 5 (9900) 35 5 (10800) FRAME WIDTH OF UNIT A & B 3 3 (1000) 6 6 (2000) 9 10 (3000) 13 1 (4000) 16 4 (5000) 19 8 (6000) (7000) 26 1 (8000) 29 4 (9000) 32 9 (10000) 36 1" (11000) 39 4" (12000) With 3 1/16" (78 mm) thick profile For units with 1 1/2" (38 mm) Triple Insulated Glass units and select units with Double Insulated Glass if no horizontal mullion is desired (for heights above 8'4") - FLOOR SUPPORTED ONLY Up to twelve panels are possible in a unit. Any custom panel size is possible up to the maximum size shown. Solid dark line on chart indicates maximum frame height possible for a given maximum frame width. For triple glazing with heights above 8 4 (2550 mm) a horizontal mullion is needed such that no glass pane is taller than 7'10" (2400 mm). A. For configurations with a swing panel hinged to a side jamb combined with a pair(s) of folding panels or for configurations with a pair(s) of folding panels only. Includes models 1L, 1R, 1L1R, 2L, 2R, 1L2R, 2L1R, 2L2R, 4L, 4R, 1L4R, 4L1R, 2L4R, 4L2R, 6L, 6R, 1L6R, 6L1R, 4L4R, 2L6R, 6L2R, 4L6R, 6L4R, 6L6R B. For all configurations. The maximum size limits are based on the maximum weight of a panel that has a net glass thickness of 1/2 (12 mm) for larger net thicker glass, this maximum size limit chart will not apply. For configurations with only even number of panels stacking to each side, the minimum width of each panel is 2' 9 1/2" (850 mm). 15

16 RELATIONSHIP OF FRAME, PANEL AND GLASS DAYLIGHT OPENING SIZES WD66 Dimensions in millimeters unless noted. Calculation applies to the standard stiles and rails with panel thickness of 66 mm (2 5/8 ) and nominal widths of 78 mm (3 1/16 ). Glass dimensions of all panels in a unit are equal unless unequal panel widths are used. Nominal Panel Height (PH) is defined as Glass Daylight Opening Height (6 1/8 ). Nominal Panel Width (PW) is defined as Glass Daylight Opening Width (6 1/8 ). Panel Height is as seen from the inside on an inward opening unit and is as seen from the outside on an outward opening unit. Please note that with the overlap of the head jamb and the sill with the panel, the Clear Opening Height will not be the same as the Panel Height. See Cross-Section Details of both stiles of each panel to determine actual Panel Width. With astragals, overlapping, etc., the actual Panel Width not only varies with position of panel in a configuration, but the inside and outside surface widths of each stile may be different. For each configuration, the Frame Width (FW) is the sum of the nominal Panel Width (PW) x the number of panels + a number (N) which is the sum of the side jamb dimensions and dimensions of space between panels in excess of the nominal Panel Width as shown in the Cross-Section Details. This can be used as a guideline. Contact NanaWall for exact calculation for particular unit. Frame Height (FH) WA66/o top hung System Raised Sill : Frame Height = Panel Height (4 11/16 ) = Clear Opening Height (6 7/8 ) Low Profile Saddle Sill / Flush Sill: Frame Height = Panel Height (5 1/2 ) = Clear Opening Height (6 3/16 ) Alternate Flush Sill: Frame Height = Panel Height (5 1/8 ) = Clear Opening Height (5 ) Frame Height (FH) WA66/u Floor Supported System Raised Sill : Frame Height = Panel Height (4 1/16 ) = Clear Opening Height (6 3/16 ) Low Profile Saddle Sill / Flush Sill: Frame Height = Panel Height (4 3/4 ) = Clear Opening Height (5 1/2 ) Frame Widths for Different Configurations with Majority of Panels Folding to Right (and their Mirror Image Configurations with Majority of Panels Folding to Left). See Maximum Size Charts for size limits. Please note that widths for units with unhinged panels or angle turns will be different. Model 1R Frame Width = 1 x Panel Width = 1 x Panel Width + 5 3/8 Model 1L1R Frame Width = 2 x Panel Width = 2 x Panel Width + 5 7/8 Model 2R Frame Width = 2 x Panel Width = 2 x Panel Width + 7 Model 3R Frame Width = 3 x Panel Width = 3 x Panel Width + 6 3/8 Model 1L2R Frame Width = 3 x Panel Width = 3 x Panel Width + 8 3/4 Model 4R Frame Width = 4 x Panel Width = 4 x Panel Width + 8 1/16 Model 1L3R Frame Width = 4 x Panel Width = 4 x Panel Width + 6 7/8 Model 2L2R Frame Width = 4 x Panel Width = 4 x Panel Width /8 Model 5R Frame Width = 5 x Panel Width = 5 x Panel Width + 7 3/8 Model 2L3R, Model 1L4R Frame Width = 5 x Panel Width = 5 x Panel Width + 9 3/4 Model 3L3R, Model 1L5R Frame Width = 6 x Panel Width = 6 x Panel Width + 7 Model 2L4R Frame Width = 6 x Panel Width = 6 x Panel Width /16 Model 6R Frame Width = 6 x Panel Width + 23 = 6 x Panel Width + 9 1/16 Model 1L6R, Model 2L5R, 3L4R Frame Width = 7 x Panel Width = 7 x Panel Width /16 Model 4L4R, Model 2L6R Frame Width = 8 x Panel Width = 8 x Panel Width /16 Model 3L5R Frame Width = 8 x Panel Width = 8 x Panel Width + 8 Model 4L5R, Model 3L6R Frame Width = 9 x Panel Width = 9 x Panel Width /16 Model 5L5R Frame Width = 10 x Panel Width = 10 x Panel Width + 9 Model 4L6R Frame Width = 10 x Panel Width = 10 x Panel Width /16 Model 5L6R Frame Width = 11 x Panel Width = 11 x Panel Width /16 Model 6L6R Frame Width = 12 x Panel Width = 12 x Panel Width /2 16

17 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 1.0 Head Jamb WD66/o (top hung) Detail 22.0 Low Profile Saddle Sill WD66/o (top hung) (For resistance against wind driven rain, drain connections by others are necessary. Sill is not centered with other frame components.) FFH Frame Height Note: For ADA compliance in commercial projects, a gasket to cover the channel in the sill at swing panels is provided for both the Low Profile Saddle Sill and Flush Sill. Detail 25.0 Thermally Broken Flush Sill WD66/o (top hung) (No rating against wind driven rain) FFH FFH Detail 2.0 Raised Sill (higher weather performance sill) WD66/o (top hung) Detail 26.0 Alternate Flush Sill WD66/o (top hung) (No Rating against wind driven rain. Sill is not thermally broken) 17

18 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 12.0 Head Jamb WD66/u (floor supported) Detail 14.0 Flush Sill WD66/u (floor supported) (No rating against wind driven rain). FFH Frame Height Detail 42.0 Raised Sill (higher weather performance sill) WD66/u (floor supported) Detail 13.0 Low Profile Saddle Sill WD66/u (No rating against wind driven rain.) FFH 18

19 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 3R.0 Panel hinged at left side jamb Detail 3.0 Panel hinged at right side jamb Detail 4.0 Swing panel with locking at left side jamb Detail 4R.0 Swing Panel with locking at right side jamb 19

20 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 5.0 Panel with running carriage set meeting left side jamb Detail 5R.0 Panel with running carriage set meeting right side jamb Detail 7C.0 and 7RC.0 Folding panels with running carriage set 20

21 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. 7.0 and 7R.0 Folding panels with locking handle for 7R.0 handle for 7.0 Detail 8.0 Two swing panels with locking. Left panel opening first Detail 8R.0 Two swing panels with locking. Right panel opening first 21

22 INWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 9.0 and 9R.0 Meeting of panels folding to opposite side (no swing panel). Running carriage sets on both panels Detail 10.0 Meeting of swing panel with locking on left and folding panel with running carriage set on right Detail 10R.0 Meeting of swing panel with locking on right and folding panel with running carriage set on left 22

23 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 1.1 Head Jamb WD66/o (top hung) FFH Frame Height Detail 22.1 Low Profile Saddle Sill WD66/o (top hung) (For resistance against wind driven rain, drain connections by others necessary. Sill is not centered with other frame components.) Detail 25.1 Thermally Broken Flush Sill WD66/o (top hung) (No rating against wind driven rain) Detail 26.1 Alternate Flush Sill WD66/o (top hung) (No rating against wind driven rain. Sill is not thermally broken.) Detail 2.1 Raised Sill (higher weather performance sill) WD66/o (top hung) Note: For ADA compliance in commercial projects, a gasket to cover the channel in the sill at swing panels is provided for both the Low Profile Saddle Sill and Flush Sill. FFH FFH 23

24 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 12.1 Head Jamb WD66/o (floor supported) Detail 14.1 Flush Sill WD66/u floor supported (No rating against wind driven rain.) FFH Frame Height Detail 42.1 Raised Sill (higher weather performance sill) WD66/u (floor supported) Detail 13.1 Low Profile Saddle Sill WD66/u (No rating against wind driven rain.) FFH 24

25 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 3R.1 Panel hinged at left side jamb Detail 3.1 Panel hinged at right side jamb Detail 4.1 Swing panel with locking at left side jamb Detail 4R.1 Swing panel with locking at right side jamb 25

26 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 5.1 Panel with running carriage set meeting left side jamb Detail 5R.1 Panel with running carriage set meeting right side jamb Detail 7RC.1 and 7C.1 Folding panel with running carriage set 26

27 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 7.1 and 7R.1 Folding panels with locking handle for 7R.1 handle for 7.1 Detail 8.1 Two swing panels with locking. Left panel opening first. Detail 8R.1 Two swing panels with locking. Right panel opening first. 27

28 OUTWARD OPENING SECTION DETAILS WD66 Drawings are shown with 3 1/16 (78 mm) stile and rail widths and 2 5/8 (66 mm) deep profiles. Nominal 3 3/4 (95 mm) and 4 3/4 (120 mm) stile and rail widths are available as well as 3 1/16 (78 mm) deep profiles for 1 1/2" (38 mm) triple glazing. Detail 9.1 and 9R.1 Meeting of panels folding to opposite side (no swing panel) running carriages set on both panels Detail 10.1 Meeting of swing panel with locking on left and folding panel with running carriage set on right Detail 10R.1 Meeting of swing panel with locking on right and folding panel with running carriage set on left 28

29 SUGGESTED TYPICAL INSTALLATION WD66 Head Jamb (top hung) INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, flashing, waterproofing, sealant, trim and other details for specific surrounding conditions must be properly designed and provided by others. INSTALLATION CONSIDERATIONS The approximate weight of a panel with double-glazing is lbs/ft 2 (27-39 kg/m 2 ), and with triple glazing is 8 lbs/ft 2 (39 kg/m 2 ). The vertical structural deflection of the header should be the lesser of L/720 of the span and ¼ (6 mm) under full loads. Although for floor supported systems, there is no vertical load on the header from the panels, structural support for lateral loads (both windload and when the panels are stacked open) must be provided. See Pre- Installation Preparation and Installation Guidelines in the General Introduction. An owner s manual with installation instructions is available upon request. Rough Opening From Subfloor Frame Height Standard Raised Sill (top hung) (higher weather performance sill) It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building s live load can be used to meet the above requirements of L/720 or 1/4 (6 mm). If not, both the dead and live loads need to be considered. For the floor supported WD66u, please note that there is no vertical load on the header. Panel Hinged At Right Side Jamb 29

30 SUGGESTED TYPICAL INSTALLATION WD66 Standard Window Sill (top hung) Raised Sill (higher weather performance sill) with Sub-Sill Installation (top hung) Alternate - Raised Sill (higher weather performance sill) Recessed Installation (top hung) INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, flashing, waterproofing, sealant, trim and other details for specific surrounding conditions must be properly designed and provided by others. See Installation Considerations on page

31 SUGGESTED TYPICAL INSTALLATION WD66 Low Profile Saddle Sill* (top hung) (Sill not centered with other frame components) INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, flashing, waterproofing, sealant, trim and other details for specific surrounding conditions must be properly designed and provided by others.. *FOR LOW PROFILE SADDLE SILL (WD66/o). For resistance against wind driven rain, the following is recommended by others 1. Remove the gasket covering the inner channel. 2. Provide necessary weepholes at the bottom of the channels and on the outside face of the sill. 3. Make necessary drain connections. Ask NanaWall for a detailed drawing. Altenative Flush Sill (top hung) Flush Sill (top hung) Notes: For ADA compliance in commercial projects, a gasket to cover the channel in the sill at swing panels is provided See Installation Considerations on Page 20 31

32 SUGGESTED TYPICAL INSTALLATION WD66 Head Jamb (top hung) INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, flashing, waterproofing, sealant, trim and other details for specific surrounding conditions must be properly designed and provided by others. Installation Considerations The approximate weight of a panel with double-glazing is lbs/ft 2 (27-39 kg/m 2 ) and with triple glazing is 8 lbs/ft 2 (39 kg/m 2 ). The vertical structural deflection of the header should be the lesser of L/720 of the span and ¼ (6 mm) under full loads. Although for floor supported systems, there is no vertical load on the header from the panels, structural support for lateral loads (both windload and when the panels are stacked open) must be provided. See Pre-Installation Preparation and Installation Guidelines in the General Introduction. An owner s manual with installation instructions is available upon request. Rough Opening From Subfloor Unit Height Standard Sill (top hung) It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building s live load can be used to meet the above requirements of L/720 or 1/4 (6 mm). If not, both the dead and live loads need to be considered. For the floor supported WD66u, please note that there is no vertical load on the header. Panel Hinged at Right Side Jamb Note: For ADA compliance in commercial projects, a gasket to cover the channel in the sill at swing panels is provided 32

33 OTHER SECTION DETAILS WD66 Other Section Details Typical Mullion Profile (Note: Different mullion widths are available) Typical Higher Bottom Rail Typical Simulated Divided Lites Muntins with Spacers Between Insulated Glass (SDL) Typical Rail with Single 1/4 Glass 33

34 INWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Detail 12.0 (78) Floor Supported Head Jamb Detail 14.0 (78) Floor Supported Flush sill (No rating against wind driven rain) FFH Frame Height Detail 42.0 (78) Floor Supported Higher Weather Performance (Raised) Sill Detail 13.0 (78) Low Profile Saddle Sill WD66/u (No rating against wind driven rain.) FFH 34

35 INWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Note: Reverse or mirror details are not shown Detail 3.0 Panel hinged at right side jamb Detail 4.0 Swing panel with locking at left side jamb Detail 5.0 Panel with running carriage set meeting left side jamb 35

36 INWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Note: Reverse or mirror details are not shown Detail 7.0 Right folding panel with locking Detail 7C.0 Folding panel with running carriage set Detail 8.0 Two swing panels with locking: left panel opening first 36

37 INWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Note: Reverse or mirror details are not shown Detail 9.0 Meeting of panels folding to opposite sides (no swing panel), running carriage sets on both panels Detail 10.0 Meeting of swing panel with locking on left and foldiong panel with running carriage set on right 37

38 OUTWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Detail 12.1 (78) Floor Supported Head Jamb Detail 14.1 Floor Supported (78) Flush sill (No rating against wind driven rain) Frame Height Detail 42.1 Floor Supported (78) Higher Weather Perfromance (Raised) Sill Detail 13.1 Low Profile Saddle Sill WD66/u (No rating against wind driven rain.) FFH 38

39 OUTWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Note: Reverse or mirror details are not shown Detail 3.1 Panel hinged at right side jamb Detail 4.1 Swing panel with locking at left side jamb Detail 5.1 Panel with running carriage set meeting left side jamb 39

40 OUTWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Note: Reverse or mirror details are not shown Detail 7.1 Right folding panel with locking Detail 7C.1 Folding panel with running carriage set Detail 8.1 Two swing panels with locking: left panel opening first 40

41 OUTWARD OPENING SECTION DETAILS WD66 WD66 with 3 1/16" (78 mm) profile Note: Reverse or mirror details are not shown Detail 9.1 Meeting of panels folding to opposite sides (no swing panel) running carriage sets on both panels Detail 10.1 Meeting of swing panel with locking on left and folding panel with running carriage set on right 41

42 DESIGN WINDLOAD CHART FOR 2 5/8 (66 MM) THICK PROFILE WD66 (Derived From Comparative Analysis) Test Unit Size: 9 2 W x H (3 panels) Inswing Unit: Negative Pressure Outswing Unit: Positive Pressure Please note that some jurisdictions may limit the use of these charts or may not accept them at all. Design pressures and/or sizes may be restricted to what was tested. For Florida approved products, please see detailed FL Evaluation Report for restrictions. Please also note that chart is only applicable for units with referenced NanaWall supplied locking ALLOWABLE DESIGN WIND LOADING - PSF PANEL WIDTH PANEL HEIGHT See Maximum Frame Size Chart for Possible Sizes 42

43 DESIGN WINDLOAD CHART FOR 2 5/8 (66 MM) THICK PROFILE WD66 (Derived From Comparative Analysis) Test Unit Size: 9 2 W x H (3 panels) Inswing Unit: Positive Pressure Outswing Unit: Negative Pressure Please note that some jurisdictions may limit the use of these charts or may not accept them at all. Design pressures and/or sizes may be restricted to what was tested. For Florida approved products, please see detailed FL Evaluation Report for restrictions. Please also note that chart is only applicable for units with referenced NanaWall supplied locking ALLOWABLE DESIGN WIND LOADING - PSF PANEL WIDTH PANEL HEIGHT See Maximum Frame Size Chart for Possible Sizes 43