1 Project name Admirals Hard Project summary FINALIST of the UK Passivhaus Awards Situated on the Stonehouse peninsula, by the banks of the River Tamar, Number 3 Admirals Hard was built in the 1950s and comprises a shop on the ground floor and WARMs office, originally a flat, on the first floor. The first floor is EnerPHit certified. The extensive retrofit works included external wall insulation, cavity wall fill, floor insulation (between the office and the shop), roof insulation at rafter level, high levels of air tightness and high-performance triple-glazed windows, as well as a self-balancing MVHR system. Project Description Projected build start date Projected date of occupation Project stage Project location Energy target Build type Building sector Property type Existing external wall construction Occupied Plymouth, Devon, England EnerPHit Refurbishment Commercial Detached Masonry Cavity Page 1

2 Existing external wall additional information Filled cavity with external insulation Existing party wall construction Floor area 80.9 m² Floor area calculation method PHPP Building certification Passivhaus certified Project team Organisation Project lead Client Architect Mechanical & electrical consultant(s) Energy consultant(s) Structural engineer Quantity surveyor Other consultant Contractor Design strategies Planned occupancy Space heating strategy Water heating strategy Fuel strategy Renewable energy generation strategy Passive solar strategy Space cooling strategy Daylighting strategy Ventilation strategy Airtightness strategy Strategy for minimising thermal bridges Modelling strategy Insulation strategy Other relevant retrofit strategies Other information (constraints or opportunities influencing project design or outcomes) Original Gas combi boiler retained Original Gas combi boiler retained Energy use Fuel use by type (kwh/yr) Fuel previous forecast measured Electri c Page 2

3 Fuel previous forecast measured Gas Oil LPG Wood Primary energy requirement & CO2 emissions Annual CO2 emissions (kg CO2/m².yr) Primary energy requirement (kwh/m².yr) previous forecast measured Renewable energy (kwh/yr) Renewables technology forecast measured - - Energy consumed by generation Airtightness ( 50 Pascals ) Date of test Pre-development airtightness - - Final airtightness - - Test result Annual space heat demand ( kwh/m².yr ) Space heat demand Pre-development forecast measured Whole house energy calculation method PHPP Other energy calculation method Predicted annual heating load - Other energy target(s) Building services Occupancy Space heating Hot water Ventilation Controls Cooking Lighting Appliances 10 Occupants Page 3

4 Renewables Strategy for minimising thermal bridges Building construction Storeys Volume Thermal fabric area Roof description Roof U-value Walls description Walls U-value Party walls description Party walls U-value Floor description Floor U-value Glazed doors description Glazed doors U-value Opaque doors description Opaque doors U-value Windows description Windows U-value Windows energy transmittance (G-value) Windows light transmittance Rooflights description Rooflights light transmittance Rooflights U-value Timber I-beams on air barrier on deck on existing rafters, fully filled with mineral wool 0.14W/m² K Block cavity wall, phenolic foam to cavity, graphite EPS to exterior, render system 0.13W/m² K Intermediate floor void filled with cellulose. Floor re-laid with air barrier and floating floor. Ground floor lobby area phenolic foam boards 0.20W/m² K Rationel Aura Plus 0.88W/m² K uninstalled 0.88W/m² K uninstalled Rationel Aura Plus 51% Page 4

5 Project images Page 5

6 Page 6