1 Architectural Inspection Building Assessment Survey Asset: P.S. 54 MINISCHOOL - QUEENS, TH STREET, New York, Inspection Id Inspection Type Time In Last Edited SA : Architectural - Senior :35 AM :03 AM AA : Architectural - Associate :11 AM :22 PM Asset Data Was the building fully accessible for inspection Inspection Access Comment Principal(s) Information Custodian Fireman Principal Name Organization Did you meet with this Principal? Did this Principal provide feedback? Summary of Principal's Feedback Answer Building Square Footage Comments on the Area Comments on the Stories (Floors) plus Basements Comments on the Number of Classrooms 8 Central station Air Handlers and Return Fans Located in Classroom ceilings were inaccessible Anita Prashad P.S. 54 Mini School The Principal provided the following comments: 1. The building requires electric upgrades to meet the demand of today's technology for the benefit of our students. 2. There are many pipe and plumbing fixtures with deficiencies throughout our school. Major upgrades to the plumbing system is required. 3. Water infiltration occurs at several locations in the building and they require immediate and effective repairs. Robert Cetina Tyrell Miller ne Comments on the Year Built 1992 Student Population 175 Staff Population 16 Weather Facade Photo 1+( Basement) Heavy Rain Corner of Hillside Avenue and 126th Street - Southeast view PB/A&W Page 1 of 15

2 Main Entrance Photo Building Assessment Survey Roof Photo Facade A - 127th Street Roof 1 - From P.S. 54 Roof Have any Systems/Major Building Components been upgraded? Have there been any New Building Additions? Tandem Schools? Leased Space? Systems: Skylight Flashing repairs to roof leaks Year: 2013 Systems: Roof Leaks repaired at Rooms 107, 108 and 109 Year: 2011 Priority Priority Exist Last Year? Priority Category Description Component Affected Location Description Person(s) tified Person(s) Title PhotoImage Potential Falling Debris Damaged scupper is a potential falling debris hazard. ROOF Roofing LEADERS, GUTTERS, DOWNSPOUT S, SCUPPERS Hillside Avenue façade facing the play yard. Robert Cetina Custodian PB/A&W Page 2 of 15

3 Structural Engineer Required Building Assessment Survey Structural Type Description Component Affected Location Description Person(s) tified Person(s) Title PhotoImage condition recorded Accessibility Accessibility Status Is the primary or secondary entrance on an accessible route? Is the building a multi-story building? Do any of the following spaces exist? Classroom, Art Room, Auditorium, Cafeteria, Computer, Gymnasiums, Library, Multipurpose Room, Science Labs For the spaces that do exist, are they ALL accessible? Is there at least one Boys and Girls or Unisex toilet accessible in the building Physical Breakdown Structure Exists Complies Required FUNCTIONAL ACCESSIBILITY Exterior Routes Exterior Entrances & Exits Exterior H/C Lifts Exterior Ramps and Railings Interior Routes Corridor and Lobby H/C Lifts Interior Corridor Doors and Hardware Interior Corridors and Lobbies Interior Elevators Interior Lobby Doors and Hardware Interior Ramps Rooms & Spaces Art Rooms Auditorium Cafeteria Classrooms 1st Floor Computer Rooms Gymnasium Library Main Office Multi-purpose Room Nurse's Room Pool Science Lab Toilet Rooms (Boys) 1st Floor Toilet Rooms (Girls) 1st Floor Toilet Rooms (Staff) 1st Floor PB/A&W Page 3 of 15

4 Building Template Building Assessment Survey Inspection Architectural AREAWAY AWNINGS AND CANOPIES CHIMNEY Material Type(s) Metal 3 - Fair METAL: DENTS, MINOR RUSTING Quantity 30 REPAIR PB/A&W Page 4 of 15

5 CHIMNEY Photo1 Building Assessment Survey Roof 2 violations recorded. COPING CORNICE DOORS DOORS AND FRAMES DOOR HARDWARE LINTELS TRANSOM/SIDE LIGHT WALLS Material Type(s) Masonry Replacement Quantity 8,500 Replacement Uom Instance on All Facades Instance Instance Quantity 8,500 Instance BRICK: DETERIORATED CONTROL/EXPANSION JOINTS WITH DAMAGED CAULKING PB/A&W Page 5 of 15

6 WALLS Elevation Building Assessment Survey Quantity 20 L.F. MAINTENANCE Photo1 Facade B violations recorded. SOFFITS LOADING DOCK LOUVER PARAPETS PLAZA DECK ROOF Roofing Replacement Quantity 13,600 Replacement Uom ROOF HATCH/SMOKE HATCH LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS 4 - Between Fair and Poor DETERIORATED SCUPPER PB/A&W Page 6 of 15

7 Building Assessment Survey Architectural Inspection ROOF Roofing LEADERS, GUTTERS, DOWNSPOUTS, SCUPPERS Quantity 2 EACH Urgency of Action PRIORITY 5 Purpose of Action LEVEL 6 Photo1 Facade F violations recorded. ROOF BARRIER ROOF CAGE ROOF FENCE ROOFING Instance on Metal: Roof 1 Instance 3 - Fair Instance Quantity 12,000 Instance Does the roof have major mechanical equipment sitting on Dunnage Steel less than 18" above the Roofing? Installation Year 1992 Source of Installation Documented METAL: ROOFING: MAJOR ACTIVE ROOF LEAKS IN INSTRUCTIONAL SPACE PB/A&W Page 7 of 15

8 ROOF Roofing ROOFING Building Assessment Survey Quantity 100 Urgency of Action PRIORITY 5 Photo1 Room 111 as shown. Rooms 112, 114 similar violations recorded. Instance on IRMA: Roof 2 Instance Instance Quantity 1,600 Instance Does the roof have major mechanical equipment sitting on Dunnage Steel less than 18" above the Roofing? Installation Year 1992 Source of Installation 4 - Between Fair and Poor Inspector Estimate IRMA: ROOFING: LOSS OF GRAVEL Quantity 30 PB/A&W Page 8 of 15

9 Building Assessment Survey Architectural Inspection ROOF Roofing ROOFING MAINTENANCE Photo1 ROOFING DRAINS Specialties BULKHEAD/PENTHOUSE CUPOLA/ SPIRES/ TOWERS DORMER DUNNAGE STEEL Roof 2 violations recorded. 3 - Fair MINOR RUSTING Quantity 40 L.F. MAINTENANCE PB/A&W Page 9 of 15

10 ROOF Specialties DUNNAGE STEEL Photo1 Building Assessment Survey Roof 2 violations recorded. HEIGHT LESS THAN 18" Quantity 60 L.F. Urgency of Action PRIORITY 1 Purpose of Action LEVEL 1 Photo1 SKYLIGHT/ROOF VENT Material Type(s) Roof 2 violations recorded. Glass 3 - Fair WATER INFILTRATION PB/A&W Page 10 of 15

11 ROOF Specialties SKYLIGHT/ROOF VENT Building Assessment Survey Quantity 10 MAINTENANCE Urgency of Action PRIORITY 5 Photo1 ROOF/GRAVITY TANK STAIRS/RAMPS: BUILDING CHEEK/FLANK WALLS RAILINGS STAIRS/RAMPS Corridor Skylight near Room 110 violations recorded. 3 - Fair CONCRETE: WORN-OUT TREAD/RISER/NOSING PB/A&W Page 11 of 15

12 Building Assessment Survey Architectural Inspection STAIRS/RAMPS: STAIRS/RAMPS Quantity 10 Photo1 Main Entrance steps violations recorded. WINDOWS Replacement Quantity 2,000 Replacement Uom GUARDS LINTELS WINDOWS INTERIOR POOLS Material Type(s) Instance on Aluminum - Double Hung: All Facades Instance Aluminum 3 - Fair Instance Quantity 2,000 Instance Installation Year 2000 Source of Installation STRUCTURAL COLUMNS/BEAMS/BEARING WALLS FLOOR STRUCTURE FOUNDATION WALLS Material Type(s) Documented Concrete PB/A&W Page 12 of 15

13 Building Assessment Survey Architectural Inspection INTERIOR STRUCTURAL ROOF STRUCTURE VAULTS-BUNKERS AUDITORIUM CAFETERIA CLASSROOMS/CORRIDORS/ADMIN SPACES Ceiling ACOUSTIC TILES: DAMAGED/MISSING Location/Instance Room 109, Corridor near Room 124 Quantity 10 Photo1 Room 109 violations recorded. ACOUSTIC TILES: DAMAGED/MISSING - ACTIVE LEAK Location/Instance Rooms 111, 112, 114 Quantity 30 Urgency of Action PRIORITY 5 Photo1 Room 111 violations recorded. Door(s) PB/A&W Page 13 of 15

14 Building Assessment Survey Architectural Inspection INTERIOR CLASSROOMS/CORRIDORS/ADMIN SPACES Floor Finish VINYL TILES: DETERIORATED SUBSTRATE Location/Instance Corridor near Room 109, 111, 122, 126 Quantity 50 Photo1 Corridor near Room 122 violations recorded. Walls MASONRY: CRACKS/SPALLING Location/Instance Corridor near Room107, 108, 109 Quantity 50 Photo1 Corridor near Room 108 violations recorded. Specialties GYMNASIUM INTERIOR DOOR HARDWARE INTERIOR GUARDS KITCHEN LIBRARY PB/A&W Page 14 of 15

15 INTERIOR LIBRARY LOCKER ROOM MULTI-PURPOSE ROOM SCIENCE DEMO ROOM SCIENCE LAB SCIENCE PREP ROOM SHOWER ROOM STAIRS/RAMPS: INTERIOR TOILET ROOMS - STAFF Ceiling Door(s) Floor Finish Stalls Walls TOILET ROOMS - STUDENTS Ceiling Door(s) Floor Finish Stalls Walls LIFE SAFETY F.D. HOLDING AREA STEEL STAIRS SITE Building Assessment Survey t Required PB/A&W Page 15 of 15