EFFISUS ECORK INSULATION

Size: px
Start display at page:

Download "EFFISUS ECORK INSULATION"

Transcription

1 EFFISUS ECORK TECHNICAL DATA SHEET Effisus Ecork Insulation EFFISUS ECORK INSULATION DESCRIPTION Expanded insulation cork board. For use as internal insulation for buildings (see EN 13710) according to the manufacturer s specifications. TECHNICAL DATA Essential characteristics Performance Standard Reaction to fire, Euroclass characteristics Reaction to fire Euroclass E Release of dangerous substances to the indoor environment Release of dangerous substances Acoustic absorption index (for floors) Sound absorption Impact noise transmission index (for floors) Dynamic stiffness Thickness, dl Compressibility Air flow resistivity Direct airborne sound insulation index Air flow resistivity Continuous glowing combustion Continuous glowing combustion Thermal resistance See table A Thermal resistance Thermal conductivity Thickness, dl Water permeability Water absorption WS 0,040 W/m.K T1-T2 (dl < 50mm) EN 13710:201 2 Water vapour permeability Water vapour transmission MU20 Compressive strength Durability of reaction to fire against heat, weathering, ageing/degradation Durability of thermal resistance against heat, weathering, ageing/degradation Compressive stress at 10% deformation Point load Durability characteristics Thermal resistance and thermal conductivity Durability characteristics CS(10)100 Satisfy Satisfy Satisfy Tensile/Flexural strength Tensile strength perpendicular to faces TR50 Durability of compressive strength against ageing/degradation No Performance Determined Compressive creep CC(0,8/0,4/10)5 1/2

2 EFFISUS ECORK TECHNICAL DATASHEET Effisus Ecork Insulation TABLE A: Thermal resistance (R) in accordance with EN 13710:2012 Thermal resistance Thermal Resistance Thickness (mm) RT (m2.k/w) Thickness (mm) RT (m2.k/w) 20 0, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,25 Fig. 1,2,3 Product testing Version V 1.1 AP 27/02/2015 2/2

3 EFFISUS ECOROOF TECHNICAL DATA SHEET EFFISUS ECOROOF+ MEMBRANE (80 mil/2.0mm) DESCRIPTION Effisus Ecoroof+ thermoplastic polyolefin based on ethylene propylene and EPDM membranes are reinforced with a polyester fabric and designed for use in mechanically fastened and adhered roofing applications. TECHNICAL DATA Tested Physical Properties Property ASTM Test Method ASTM Requirements MD* 80 Mil (2.0mm) XMD** Strength Tearing Strength D 751 >55 lbf (245 N) 64 lbf (287 N) 179 lbf (796 N) Breaking Strength D 751 >220 lbf (978 N) Longevity 464 lbf (2,065 N) 439 lbf (1,953 N) Overall Sheet Thickness D %, -10% in. (2.01 mm) Thickness of Coating Over Fabric Weather Side D 6878 >0.015 in. (0.381 mm) in. (0.889mm) Elongation at Reinforcement Break D 751 >15% 29% 31% Ozone Resistance D 1149 No cracks Pass Heat Aging (Pass/Fail) D 573 Pass Pass Water Absorption D 471 ±3% max. 2.2% Post Xenon Visual Inspection D 6878 Pass Pass Aged Performance Post Heat Aged Breaking Strength D 751 >90% retained values Pass, 473 lbf (2,104 N) Pass, 450lbf(2,002 N) Post Heat Aged Elongation at Reinforcement Break D 751 >90% retained values Pass, 31% Pass, 32% Post Heat Aged Tearing Strength D 751 >60% retained values Pass, 62 lbf (278 N) Pass, 160 lbf (715 N) Post Heat Aged Weight Change D 1204 ±1% max. <0.1% Post Heat Aged Linear Dimension Change D 6878 ±1% max. <0.1% Installation Brittleness Point D C (-40 F) -40 C (-40 F) Factory Seam Strength D 751 >66 (294) 137 lbf (609 N) Weight NA NA 0.40lb/ft² (0.017kg/m²) * MD: Machine Direction **XMD: Cross Machine Direction All data represents test values. 1/4

4 EFFISUS ECOROOF TECHNICAL DATA SHEET TECHNICAL DATA Supplemental Testing Physical Properties ASTM Test Method Standard for ASTM D 6878 (Min.) 80 mil (2.0mm) Result Dynamic Puncture D 5635 N/A 35 Joules Static Puncture D 5602 N/A Pass@ 44lb(20kg) Reflectance C 1549 N/A 78% Emittance C 1371 N/A 0.87 Resistance of Synthetic Polymer Material to Fungi Puncture Resistance (FTMS 101C, Method 2031) G 21 N/A 0 rating N/A N/A 526 lb (239 kg) Moisture Vapor Transmission E 96 N/A Hydrostatic Resistance, Mullen D 751 N/A 0 g/m2 per 24 hours 602 PSI (4,150 kpa) Packaging and Dimensions Roll Widths 5' (1.52 m) 8' (2.44 m) 10' (3.05 m) Roll Lengths 75' (22.86 m) Roll Coverage 375 ft² (34.84 m²) 600 ft² (55.74 m²) 750 ft² (69.68 m²) Rolls per Pallet 8 Pallet Weight 1384 lbs (627.8 kg) 1880 lbs (852.8 kg) 2760 lbs ( kg) Pallets per Truck* *Assumes 48' flatbed truck and does not reflect pallets of accessories or impact of mixed sizes. Peak Advantage Guarantee Information Product 80 mil (2.0 mm) Guarantee Term 5, 10, 15, 20, 25, or 30 years 2/4

5 EFFISUS ECOROOF TECHNICAL DATA SHEET Features Thickness Over Scrim Optimized and tested on a continual basis with a state-of-the-art thickness gauge to verify that the thickness valued by our customers is incorporated into the sheet. One of the Widest Melt Windows Promotes better welds over a wider variety of speeds and temperatures, and leads to a softer,more flexible and workable sheet. Reinforced fabric scrim layer and top-ply thickness Lends to durable physical properties including: - Long-term weathering, UV resistance and heat-aging properties; - High breaking and tearing strength. Optimized formulation Delivers high-performance ozone resistance, cool roof reflectivity and overall weather resistance. Energy and Environment Energy and the Environment CRRC Initial Reflectivity: 0.77 Emissivity:0.87 CA Title 24 Pass Reflectivity: 0.77 Emissivity:0.87 Initial Reflectivity: 0.78 ENERGY STAR 3 Yr. Aged Reflectivity: 0.77 Cleaned 3 Yr. No LEED SRI of 101 as tested by ASTM E Recycled Content: Postconsumer: 0% Postindustrial: 5% Results shown are for the initial reflectivity and emittance for white membranes unless otherwise indicated; emissivity values for California Title 24 are tested per ASTM C 1371; LEED emissivity values are tested per ASTM E 408. Installation/ Application Refer to Effisus Ecoroof Application Guides and Detail Drawings for instructions. 3/4

6 EFFISUS ECOROOF TECHNICAL DATA SHEET System Compatibility Do not use with Multi-ply systems. Compatable with the selected Single Ply Systems Mechanically Fastened Fully Adhered Please refer to the specific Up-Way Systems sheets for details. Colours White, Grey* and Tan* * Grey and Tan lead times are subject to availability and may require an upcharge for smaller projects. Codes and Approvals Meets or exceeds the requirements of ASTM D 6878 Version V 1.2 AT 02/05/2013 4/4

7 EFFISUS ECOFACADE TECHNICAL DATASHEET Effisus Breather+ Membrane DIN EN EFFISUS BREATHER+ MEMBRANE DESCRIPTION Application area: Wall lining membrane behind closed facades. Film: TEEE monolithic. Cover and protection spunbond: polypropylene microfiber fleece TECHNICAL CHARACTERISTICS Technical characteristics Standard Value Colour Black Surface weight EN ± 5 g/m2 Thickness EN ± 0.05 mm Water vapour resistance factor µ EN ISO sd - value EN ISO ± 0.02 m g - value 0.25 ± 0.10 MNs/g Water vapour permeance ASTM E US perms Fire behavior EN E Exposure time 3 months Water column EN mm Water resistance un-/aged* EN 1928 W1 / W1 Tensile strength MD/CD EN ± 20 N/5cm / 140 ± 20 N/5cm Tensile strength MD/CD aged* EN ± 20 N/5cm / 120 ± 20 N/5cm Elongation MD/CD EN ± 10 % / 90 ± 10 % Elongation MD/CD aged* EN ± 10 % / 70 ± 10 % Nail tear resistance MD/CD EN ± 20 N / 140 ± 20 N * Artificial ageing by long tern EN 1297 / EN 1296 Passed Flexibility at low temperature EN ºC Temperature resistance -40 ºC a +100 ºC Coefficient of thermal conductivity 0.17 W/mK Area of Application For making walls externally windproof. Installation on boarding, wood-based panels and all insulation mats and boards.

8 EFFISUS ECOFACADE TECHNICAL DATASHEET Effisus Breather+ Membrane Advantages Strong 3-ply structure for protecting the wall structure. Protective function as a result of non-porous functional membrane that actively manages moisture. High nail tear resistance. For use behind closed facades. 3 months outdoor exposure. General conditions Effisus Breather+ Membranes can be laid flat either at right angles to or along the sub-structure without sagging. Horizontal installation is preferable with regard to water tightness during the construction phase. The membrane must be secured in areas where water collectively drains off. Additional measures during the building phase (e.g. covering with tarpaulin) should be taken in the case of occupied buildings or buildings that need particular protection. Covering with tarpaulin should also be considered in the case of extended interruptions to work. The information provided here is based on practical experience and the current state of knowledge. We reserve the right to make changes to the recommended designs and processing or to make alterations due to technical developments and associated improvements in the quality of our. products. We would be happy to inform you of the current technical state of the art at the time you use our products. Original document: /25/2014 V 1.1 AP 18/12/2014