1 Covering
2 Covering Design Regions
3 Roof Covering
4 Roof Covering (SSR) 24 coverage w/ 3 seam height Machine seamed, in-place Attached to roof secondary (purlins, widebay truss purlin or bar joist) w/ a concealed sliding clip which allows 1 5/8 thermal movement each direction, 3 1/4 total
5 SSR PANEL CLIPS Fixed Sliding
6 Center Seaming Tab in Slot (2) Fasteners Per Clip At Endlaps and Ridge End. Clip Must Be Installed Under Panel Stiffener
7 Note: Taller SSR clips are used with thermal block/super block. Adjustments may be desired in eave height input which is measured from top of purlins.
8 SSR Profile
9 Roof Covering (SSR) Weather-tight roof system 24 gage w/ 22 gage available upon special request 25 year Finish Warranty Galvalume KXL (Kynar 500 or Hylar 5000 ) Variety of colors to choose from Use with Blanket Insulation up to 6 thick (over purlins) or Rigid Board up to 3 1/2 thick ¼ : 12 minimum roof pitch
10 Roof Covering (SSR)
11 SSR Staggered Lap Panel lap is 9 above the Purlin Staggered Lap is typically 5-0 (purlin spacing) Sheet either direction, except with Tuflites Notch is factory applied
12 SSR Staggered Lap
13
14
15 SSR Ridge
16 SSR Ridge Detail
17 SSR Ridge Detail
18
19
20
21 SSR and HWR Profile
22 SSR High Wind Roof The HWR roof system is primarily intended for the higher coastal wind regions, Caribbean, etc.. It is not intended to replace the SSR roof system with 90 to 110 mph +/- winds. The SSR system, with lower wind speeds, would be cheaper than the HWR. The HWR with higher winds will price out in most all cases. For wind speeds greater than 110 mph, and up to 200 mph, the HWR roof system will design w/o unpriced items. (assumes that one would select deeper depth purlins as required) Purlin spaces for the 110 to 200 mph case above ranged from 4 6 to 5 0 in the roof field and rakes, eaves lower.
23 SSR HWR
24 HWR Clips
25 HWR Factory Mutual (FM) ratings with 5-0 purlin spacing and 24 gage panel Florida, Miami-Dade approved UL approved expansion and contraction is the same as standard SSR as limited by the bull-nose style ridge trim Same eave and rake trims as SSR
26 HWR 8 is the standard clip length used at all purlins 12 clip used at corner and edge zone conditions where 8 clips not sufficient Used with ZEE purlins in depths of 8 ½, 10, and 11 ½ Purlin Channel bracing required May not be used with 7 deep purlins(due to purlin channel bracing being required) Superblock not available at this time
27 SSR High Wind Roof No rake subpurlins needed. (possibly with FM rated assemblies requiring reduced spaces) VPCommand will automatically populate the rake and corner zones with 12 clips as required for design. Great FM ratings with 5 purlin spaces and 24 ga. panels Florida, Miami-Dade approved. UL approved. Expansion/contraction same as SSR as limited be the bull-nose style ridge trim. Same eave and rake trims as SSR.
28 SSR
29 SSR
30 SSR Fixed Eave
31 SSR Fixed Centerline (Floating Eave)
32 SSR Fixed Eave
33 SSR Fixed CL / Floating Eave
34 SSR 6 Roof Step Expansion
35 Expansion & Contraction
36 Expansion & Contraction
37 Floating Roof System
38 SSR Insulation over purlins
39 SSR Thermal Block
40 SSR Module Strip
41 SSR SuperBlock
42
43 Thermal Performance - PR
44 Thermal Performance - SSR
45 Thermal Performance-SSR (Thermal Block)
46 Thermal Performance-SSR (Superblock)
47 Seamer Tool
48 Seamer Tool
49 Contact your VP Service Center for assistance. SSR Seam Clamp
50 Roof Covering Standing Seam (SSR) Panel Rib (PR)
51 Panel Rib
52 Roof Covering (PR) 36 coverage Available in 26, 24, & 22 gages Available in Galvalume & KXL finishes
53
54
55 Roof Covering (PR) Attached to purlins with selfdrilling fasteners Use with Blanket Insulation up to 4 thick 1 / 2 :12 minimum roof pitch Cannot be used on TP/bar joist
56 Panel Rib
57
58 Roof Covering Standing Seam (SSR) Panel Rib (PR) SLR II
59 Roof Covering (SLR II) 2 SLR II Architectural Standing Seam Roof System (2 Seam Height) Available in a variety of KXL colors
60 Roof Covering (SLR II) 16 Coverage with 2 Seam Heights Machine seamed in-place Attached to roof secondary (purlins or bar joist) w/ a concealed clip which allows 1 thermal movement. Weather tight Roof System
61
62
63 SLR II
64
65 Roof Covering (SLR II) 24 Gage only with 2 High Rib 25 - Year Warranted KXL Finishes Variety of colors to choose from Use with Blanket Insulation up to 6 thick Thermal Blocks are Required
66 SLR II Ridge Detail
67 SLR II
68 SLR II
69 SLR II
70 SLR II
71 SLR II
72
73 Thermo-Deck System
74 Components
75 TLS Processing Guidelines The roof panel lengths will need adjustment at the splices. Panel lengths will need to be adjusted by the rise of the depth of the TLS System
76
77 VP Roof Factory Mutual SSR and SLR II Roof Systems are approved in various type applications and listed in the FM Approval Guide. 24 Ga SSR is available in Class 1-60, 1-75, Ga SSR is available in Class 1-75, 1-90, Ga SLR is available in Class 1-90,
78
79 Walls: PR, VR, RPR Roofs: PR, SSR
80 PR, VR, SSR
81 SLR II
82 Cool Roofing (reduces heat island effect)
83 Covering Wall Covering
84 Wall Covering Panel Rib (PR) Vee Rib (VR) Reverse Panel Rib (RPR)
85 Wall Covering Panel Rib (PR)
86
87 Panel Rib (PR) 36 Coverage Available up to 41-0 long Variety of end conditions available Available with KXL & Galvalume finishes Fasteners match wall color 26, 24 & 22 available Use with insulation up to 4 thick
88
89 Crimped Base Panel Rib
90 Crimped Base Panel Rib
91 Crimped Base Panel Rib
92 Crimped Base Panel Rib
93 Panel Rib Wall
94 Panel Rib Wall
95 Vee Rib Wall
96 Vee Rib (VR) 36 Coverage Available up to 41-0 long Stucco Embossed Panels available KXL finishes Fasteners match wall color 26, 24, & 22 gage Use with insulation up to 4 thick
97
98 Vee Rib Base
99 Vee Rib
100 Vee Rib
101 Wall Covering Reverse Panel Rib (RPR)
102 Reverse Panel Rib (RPR) 36 Coverage Available up to 41-0 long Available with KXL & Galvalume finishes Fasteners match wall color 26, 24 & 22 available Use with insulation up to 4 thick
103 Reverse Panel Rib (RPR)
104 Reverse Panel Rib (RPR)
105 Wall Covering Panel Rib (PR) Vee Rib (VR) Reverse Panel Rib (RPR)
106 Wall Covering Crating Options: Max. Cnt. per Crate Request a maximum quantity of panels per crate / bundle to Manufacturing. Max. Wt. per Crate Request a maximum weight of panels per crate / bundle to Manufacturing. Max. Dist. Combine Sets The maximum distance between like panel set to be combined.
107 Wall / Roof Material NBVP The builder is must supply the actual weight of these materials.the weights on this page are only for reference. WALLS ROOFS Brick Copper or tin 1 psf 4" 40 psf Corrugated steel See Manufacture 8" 80 psf 3-ply ready roofing 1 psf 12" 120 psf 3-ply felt and gravel 5 1/2 psf 5-ply felt and gravel 6 psf Hollow Concrete Block (Heavy Aggregate) 4" 30 psf Shingles 6" 43 psf Wood 2 psf 8" 55 psf Asphalt 3 psf 12 1/2" 80 psf Clay tile 9-14 psf Slate 1/4" 10 psf Hollow Concrete Block (Light Aggregate) 4" 21 psf Sheathing 6" 30 psf Wood 3/4" 3 psf 8" 38 psf Gypsum 1" 4 psf 12" 55 psf Insulation (per 1" thick) Miscellaneous Loose 1/2 psf Window, glass, frame, & 8 psf Poured-in-place 2 psf sash Rigid 1 1/2 psf
108 Thermal Performance PR, VR
109
110 FP-12 Soffit FP 12 Soffit panel only Flush Panel Design 12 Module 7/8 Panel Height 24 and 22 Gage No Clips Required Available vented (perforated) & Stiffening Beads ( 1 or 2)
111 Girt Strapping for Panel NBVP
112 FP-12 Soffit
113 Texture Clad
114 TextureClad 16 Wide Coverage Lengths 2 to 22 Stackable Panels 20 gage G-90 Galvanized Steel Concealed Fastener Installation Attaches Directly to Wall Girts (max. span of 5-6 )
115 TextureClad
116 Aspen Ice Arena
117 OMETEK
118 TextureClad Close-up of window and door trim
119 TextureClad
120 TextureClad
121 ThermalClad Wall Panels Architectural (36 Width) Planked (42 Width) Reveal (42 Width) Tuff-Wall (42 Width) Roof Panel TCR 42 (42 Width) Thickness: 2, 2.5, 3 & 4
122 ThermalClad Wall Panel Length Gauge Interior Exterior Gauge Varies Stucco Embossed Concealed Fastener Max R Value PVDF Finish Reveal
123 ThermalClad Roof Panel 42 Wide Length Gauge Exterior Stucco Embossed Concealed Fastener Max R Value 32.3 PVDF Finish 2 High SLR Rib TCR - 42 TCR - 42
124 Oil Canning (NOT VP Buildings)
125 Oil Canning (NOT VP Buildings)
126 Oil Canning
127 Oil Canning-Ways to Reduce
128 Oil Canning-Ways to Reduce
129 Oil Canning-Ways to Reduce
130 Oil Canning