Rubber Underlay DURAFIT 500. Durafit 500. Underlay Technical Specification

Size: px
Start display at page:

Download "Rubber Underlay DURAFIT 500. Durafit 500. Underlay Technical Specification"

Transcription

1 Underlay

2 Rubber Underlay Durafit 500 DURAFIT 500 Underlay Technical Specification Certification Guarantee Guaranteed for the serviceable lifetime of the carpet when used in accordance with the End Use Classification Crumb Rubber Suitable for both stretch-fit and double-stick applications End Use Classification (BS 5808 : 1991): HC/U, Heavy Contract Use Standard Specifications Nominal square weight Nominal roll weight Roll area* BS 5808 : 1991 End Use Classification Nominal thickness Work of compression minimum 50 J/m 2 Retention of work of compression (min 40) Compression after dynamic loading Loss in thickness after dynamic loading (max 15) Loss in thickness after static loading (max 15) Breaking strength (lenght/width) min. 40N Extension under force (length/width) max. 10@40N Resistance to cracking (not greater than 50 mm) Flammability Hot metal nut test (tested in interfloor laboratory) German radiant panel (tested in conjuction with Brinton s Marquis carpet) Kleinbrenner (tested in conjuction with Brinton s Marquis carpet) French rediant panel (tested in conjuction with Axminster 1126/47 carpet) Critical radiant flux (tested in conjuction with Axminster 1126/47 carpet) Other Specifications Odour Antimicrobial and mildew resistant Colour / backing Packaging Thermal resistance Impact sound reduction (Delta Lw) Emissions (US Carpet & Rug Institute) 2100 g/m 2 (62 oz/yd 2 ) 31.6 kg (70 ibs) 15.07m 2 (1.37m x 11.0m) HC/U, Heavy Contract Use 5.25mm 75 J/m mm N / 300N 1.0 / 0.5 Pass Low radius of effects of ignition Material complied with B1 classification Material complied with B2 classification Class M3 Cat 1: Institutional buildings BS 4051 BS 4052 BS 3939 BS 2576 BS 5808 BS 4790 & BS 5287 DIN 4102 pt 14 DIN 4102 pt 14 NFP ASTM E648 / NFPA253 No objectionable odour Yes Black / woven polypropylene backing Grey film / black print 0.83 togs BS dB BSEN ISO : 1998 and BSEN ISO : 1997 Meets low VOC emission criteria Notes * The nominal roll dimensions have been quoted. These may vary slightly, but will still equate to the area quoted. This does not constitute a manufacturing specification. It details important performance and physical characteristics only. _ +5

3 Rubber Underlay Power POWER Underlay Technical Specification Sponge Rubber Suitable for the stretch-fit installation of carpets End Use Classification (BS 5808 : 1991): L/U, Luxury Use Standard Specifications Nominal square weight Nominal roll weight Roll area* BS 5808 : 1991 End Use Classification Nominal thickness Work of compression minimum 50 J/m 2 Retention of work of compression (min 40) Compression after dynamic loading Loss in thickness after dynamic loading (max 15) Loss in thickness after static loading (max 15) Resistance to cracking (not greater than 50 mm) Flammability (Hot metal nut test) 3254 g/m 2 (96 oz/yd 2 ) 35.7 kg 10.96m 2 (1.33m x 8.24m) L/U, Luxury Use 5.60mm 140 J/m mm Pass Low radius of effects of ignition BS 4051 BS 4052 BS 3939 BS 5808 BS 4790 & BS 5287 Certification Other Specifications Odour Antimicrobial and mildew resistant Colour / backing Packaging Thermal resistance Impact sound reduction (Delta Lw) Emissions (US Carpet & Rug Institute) No objectionable odour Yes Gold / printed Textron backing Yellow film / blue print - BS BSEN ISO : 1998 and BSEN ISO : 1997 Meets low VOC emission criteria Guarantee Guaranteed for the serviceable lifetime of the carpet when used in accordance with the End Use Classification Notes * The nominal roll dimensions have been quoted. These may vary slightly, but will still equate to the area quoted. This does not constitute a manufacturing specification. It details important performance and physical characteristics only. _ +5

4 PE Foam - Silver Underlay 6 mm 8 mm 10 mm 12 mm Heat Insulation Characteristics It has many characteristics that make it distinguished from other competing materials:. Shock Absorbing. Water Proofing. Heat Insulating. Flexible and Easy Handling. Easy Laminating. Easy Punching. Strong Chemical Resistance. Non-Hazardous Technical Specification Thickness 6mm 8mm 10mm 12mm Width 1m 1m 1m 1m Length 25m 25m 25m 25m

5 Technical Specification Description Unit Value Test Method Thickness Density Cell Size Thermal Conductivity Thermal Resistance Tensile Strength Elongation Heat Dimensional Stability Water Absorption Moisture Permeability Tearing Strength The Permanent Compression set (100kg/cm 2 ) Mm g/cm 2 Mm W/m. 0 C M 2.0 /w kg/cm 3 Mg/cm 2 g/m 2.24hr Kg/cm 6mm MD 3.8/ CD 2.8 MD 100/ CD mm MD 3.6/ CD 2.7 MD 105/ CD mm MD 3.67/ CD 2.72 MD 108/ CD mm MD 4.2/ CD 2.05 MD 105/ CD ASTM D ASTM D ASTM D ASTM D ASTM C ASTM D ASTM D ASTM D ASTM D ASTM D Density Cell Size Permanent Chemical resistant Water absorption Moisture permeability Poisonous gases in case of perfect combustion Weight Wear guarantee ASTM D ASTM D ASTM D T ASTM D ASTM D g/cm 3 mm 9 for 100kgf/cm 2 Excellent 0.37mg/cm 2.24hr Almost None kg/roll Life time of the carpet Characteristic of Pe Foam Underlay. Extends the life of the carpet. Doesn t absorb water. Provides comfort to the feet. Provides a silent step to reduce noise transfer in multi-layered buildings. Stop heat-cold transfer from the floor to the carpet. Non-poisonous and chemical resistant. Works with all kinds of glue even the cheapest. Doesn t need wooden grippers at the room s floor angles. Doesn t need glue tape under the carpet. Price is very competitive

6 Felt Underlay 600 gm 750 gm 950 gm 1250 gm Specification 1. Pure fiber Polypropylene (Recycle) - ACC. to 20 A 9AATCC) Anti bacteria - ACC. to AATCC Flame retardant ACC. to AATCC Resist the fire expansion - ACC. to FF The total weight with Latex 600 GRMS/SQM and the thickness 5mm with Latex 6. The total weight with Latex 750 GRMS/SQM and the thickness 5.5mm with Latex 7. The total weight with Latex 950 GRMS/SQM and the thickness 6.5mm with Latex 8. The total weight with Latex 1250 GRMS/SQM and the thickness 8.5mm with Latex 9. The tota weight and thickness may vary +/ The width 4mm

7 Parquet Underlay FREON FREE LAMINATE 1 m x 20 m = 20 m gm Developed for floating laminate flooring - Adapted to laminate flooring & to 7-15mm floating woodfloors 750 gm 1250 gm

8 Technical Specification LAMINATE Description Unit Value Test Method Thickness Density Cell Size Thermal Conductivity Thermal Resistance Tensile Strength Elongation Heat Dimensional Stability Water Absorption Moisture Permeability Tearing Strength The Permanent Compression set (100kg/cm 2 ) Mm g/cm 3 Mm W/m. 0 C M 2.0 /w kg/cm 3 Mg/cm 2 g/m 2.24hr Kg/cm ASTM D ASTM D ASTM D ASTM D ASTM D ASTM D ASTM D ASTM D ASTM D Characteristics of Parquet Underlay. Extends life of wooden and laminate floorings. Doesn t absorb water. Reduces noise transfer in multi layered building. Stops heat-cold transfer from and to the wooden floor.. Non-poisonous and chemical resistant