8

9

10

11

12 UNA-CLAD UC-3 Item Description Standing Seam Panel For Architectural Metal Roofing Varies 1.5" Product Information Description: Firestone UNA-CLAD UC-3 Roofing Panel is a factory formed double-lock, architectural standing seam metal roof panel that provides a traditional look and utilizes mechanical seaming to enhance the architect s design needs. The UC-3 roofing panel allows the designer to design or specify various radius roof profiles. The minimum slope requirement for a Firestone Red Shield Warranty is 3:12. For warranty requirements for slopes between 3:12 and 1:12, please contact your Roof System Advisor. Method of Application: 1. A smooth, solid substrate of plywood, OSB, or a rigid insulation board mechanically attached to a steel deck is recommended for the Firestone UC-3 metal roof panel. 2. Firestone UC-3 panels must be installed in a sequential order. 3. Application of a Firestone approved underlayment prior to panel installation is recommended. 4. Panels must be locked in the field by a mechanical seamer. NOTE: Install assembly according to Firestone Metal Design and Application Guides found on the Firestone website. Follow approved installation details. Storage: Firestone metal panels should be stored in a well ventilated, dry place where no moisture can contact them. Moisture (From rain, snow, condensation, etc.) trapped between layers of material may cause water stains or white rust, which can affect the service life of the material and will detract for the appearance. If outdoor storage cannot be avoided, protect the panels with a ventilated canvas or waterproof paper cover. Do not use plastic, which can cause condensation. Keep the material off the ground in an inclined position with an insulator such as wood. Protective film may degrade or become brittle with long term exposure to direct sunlight. Precautions: Oil canning is not a cause for rejection. Heavier gauges, narrower widths, striations, and embossing minimize oil canning. Ensure the mechanical seamer is properly adjusted prior to field seaming to reduce the risk of seam damage. Firestone recommends a minimum bend radius of 2T. Anything less than a 2T bend radius can cause crazing to the material. Sealant for end laps and lap joints shall be non-drying, non-toxic, and non-shrinking with a serviceable temperature of -60 to 212 F (-51 to 100 C). Quality, long-life butyl sealants work best as a gasket sandwiched between two pieces of metal. Non-acetic cured silicone color matching sealants are recommended when voids must be filled. Sealants are not a substitute for proper assembly and workmanship. Firestone Building Products Sales: (800) Technical (800) TIS # /02/2015 Page 1 of 3

13 UNA-CLAD UC-3 Precautions Continued: Exercise caution when lifting, moving, transporting, storing or handling Firestone metal to avoid possible physical damage. Refer to Safety Data Sheets (SDS) for safety information. Immediately remove protective film after installation. LEED Information: Post Consumer Recycled Content: 0% Post Industrial Recycled Content: 0% Manufacturing Location: Anoka, MN Warren, MI College Park, GA Las Vegas, NV *NOTE: LEED is a registered trademark of the U.S. Green Building Council. Product Data Tapered Panels: Yes* Radius Panels: Yes; 8.0' (2,438 mm) Min. Convex Only* Stiffening Ribs: Optional Striations: Optional Sealant: Optional In-Seam, Thermally Applied Standard Panel Surface: Smooth Optional Panel Surface: Stucco Embossed Clip: UC-3 Stainless Steel Expansion Clip, UC-3 Super Clip & UC-3 Fixed Clip NOTE: * Not Manufactured at all Facilities. Testing is not applicable for all combinations of substrates, materials, and dimensions. All construction assemblies must be installed in accordance with the tested assembly. Please refer to the Metal Code Approval Guide on the Firestone website for tested assemblies and code listings. Please contact your Building Systems Advisor for warranty requirements and additional Information. Product Size Panel Width: Optimal Panel Width: Seam Height: Minimum Panel Length: Maximum Panel Length: 8" (203.2 mm) 20" (508.0 mm) 12" (304.8 mm) & 20" (508.0 mm) 1.5" (38.1 mm) 36" (914.4 mm) 600" (15.24 m) Technical Information Uplift Resistance: Air Infiltration: Structural Performance: Water Penetration: Fire Rating: Hail Impact Rating: Miami-Dade County & Florida Building Code: UL 580 Class 90 ASTM E 283 & E 1680 ASTM E 330 & E 1592 ASTM E 331 & E UL Class A Rated Assemblies, UL 263 and UL 790 Class 4, UL 2218 Approved Firestone Building Products Sales: (800) Technical (800) TIS # /02/2015 Page 2 of 3

14 UNA-CLAD UC-3 Typical Properties Material and Thickness Metal Specification: Available Finishes: Aluminum 0.032" (0.81 mm) 0.040" (1.02 mm) Galvanized Steel 26 ga. (0.48 mm) 24 ga. (0.64 mm) 22 ga. (0.79 mm) Galvalume Steel 26 ga. (0.48 mm) 24 ga. (0.64 mm) 22 ga. (0.79 mm) Copper 16 ga. (0.56 mm) 20 ga. (0.69 mm) Zinc 0.028" (0.7 mm) 0.032" (0.8 mm) 0.040" (1.0 mm) Base Metal: Aluminum Minimum Yield: 21 KSI (145 MPa) Thermal Expansion: 12.6 x 10-6 in/in/ F (22.2 m/m.k x 10-6 ) Mod. Of Elasticity: 10.0 x 10 3 x KSI (68.9 MPa) Base Metal: AISI-G90 Galvanized steel Minimum Yield: 33 to 45 KSI (227 to 310 MPa) Thermal Expansion: 06.7 x 10-6 in/in/ F (13.9 m/m.k x 10-6 ) Mod. Of Elasticity: 29.0 x 10 6 x KSI (200 GPa) Base Metal: AZ-50 Hot Dipped Galvalume Minimum Yield: 50 KSI (345 MPa) Thermal Expansion: 06.7 x 10-6 in/in/ F (13.9 m/m.k x 10-6 ) Mod. Of Elasticity: 29.0 x 10 6 x KSI (200 GPa) AGSC minimum copper content of 99.9% copper, silver counting as copper, cold rolled from ingots of 122 alloy. Thermal Expansion: 9.3 x 10-6 in/in/ F (16.5 m/m.k x 10-6 ) AGSC copper meets and/ or exceeds ASTM B370 specification. RHEINZINK : Electrolytic high-grade, 99.9% pure, fine zinc (DIN EN 1179) titanium copper alloy. Certified according to DIN ISO 9001: 1994 Thermal Expansion: 2.2 mm/m x 100K (16.5" x 10-6 in/in/ F) Anodized Kynar 500 /Hylar 5000 Unpainted/Mill Finish Kynar 500 /Hylar 5000 Unpainted G90 Acrylume Clear Acrylic Coated Natural Shiny Pre-weathered Blue-Gray Pre-weathered Graphite Gray NOTE: For standard color selection, consult the current UNA-CLAD Color Selection Guide. Custom color services are available upon request. Consult the current base metal Sheet & Coil TIS for additional information on the base metal and coating. Not all materials and thicknesses are available from all locations. Please contact Quality Building Services Technical Department at for further information. This sheet is meant to highlight Firestone products and specifications and is subject to change without notice. Firestone takes responsibility for furnishing quality materials which meet published Firestone product specifications. Neither Firestone nor its representatives practice architecture. Firestone offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Firestone accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Firestone representative is authorized to vary this disclaimer. Firestone Building Products Sales: (800) Technical (800) TIS # /02/2015 Page 3 of 3

15 RED SHIELD WARRANTY SYSTEMS F F F F B F F, B F F B, FF, F, FIRESTONE UNA-CLAD RED SHIELD SERIES Building on proven standing seam technology, Firestone developed the UNA-CLAD Red Shield Series to provide designers, architects and building owners with a wide selection of beautiful, durable and functional metal roofs he ed hield eries is available in a variety of colors, materials, widths, te tures, pro les and seam designs UNA-CLAD UC-3 This double-lock standing seam system uses mechanical sealing for a durable, virtually leak proof seal. - roofs create a traditional look, and allo speci ed radius pro les to enhance the architect s design. Standard UC-3 materials are painted steel; painted and anodized aluminum; architectural grade sheet copper and zinc. vailable ith embossing, striations and ribs at and pencil to minimize oil-canning. UNA-CLAD UC-4 The patented seam design snap locks securely and fastens to a solid substrate without the use of clips. This provides superior leak resistance and can reduce labor by up to 30%. Standard UC-4 materials are painted steel; painted and anodized aluminum and architectural grade sheet copper. vailable with embossing, striations and ribs at and pencil to minimize oil-canning.

16 COLOR SELECTION GUIDE B E E AL D A E AR AL GRA DAR BR E E TRA DAR BR E L AL RED TERRA TTA REGAL RED AWARD BLUE BLUE REGAL BLUE TEAL AT A GREE ER D GREE ART RD GREE E L GREE L ER E ALL LA ER A AG E ETALL Colors shown are as close to actual colors as allowed by the printing process. Your local sales rep can provide actual metal samples and answer questions about custom colors and other special requests.

17 DESIGNER SHINGLES COLOR AVAILABILITY Atlantic Blue Hunter Green Burnt Sienna Mist White Charcoal Black Moire Black Landmark, shown in Georgetown Gray Cobblestone Gray Mojave Tan LANDMARK Colonial Slate Cottage Red Driftwood Georgetown Gray Pewter Resawn Shake Silver Birch Sunrise Cedar Two-piece laminated fiberglass-based construction Classic shades and dimensional appearance of natural wood or slate 229/235 lbs. per square Lifetime limited transferable warranty* 10-year StreakFighter algae-resistance warranty 10-year SureStart protection 15-year 110 mph wind-resistance warranty Wind warranty upgrade to 130 mph available. CertainTeed starter and CertainTeed hip and ridge required CertainTeed Starter and hip and ridge accessory available (see details in back of brochure) * See warranty for specific details and limitations. CertainTeed products are tested to ensure the highest quality and comply with the following industry standards: Fire Resistance: UL Class A UL certified to meet ASTM D3018 Type 1 Wind Resistance: UL certified to meet ASTM D3018 Type 1 ASTM D3161 Class F Tear Resistance: UL certified to meet ASTM D3462 CSA standard A123.5 Wind Driven Rain Resistance: Miami-Dade Product Control Acceptance: Please reference to determine approved products by manufacturing location. Heather Blend Weathered Wood Quality Standards: ICC-ES-ESR-1389 & ESR