1 Certificate No: EW369A Rockwool UK - REDArt Silicone Description of Product The REDArt Silicone system is produced from insulation made of renewable volcanic rock. There are a number of options in thickness and fixing methods to meet different substrate conditions. The ROCKWOOL REDArt Silicone system is applied in two coats. The first includes a reinforcing mesh to impart strength to the system. The second coat is a decorative colour finish. Photo/isometric drawing provided by manufacturer Key Factors Assessed Mechanical Resistance & Stability - Approved Document A Safety in case of Fire Health, Hygiene and Environmental - Approved Document C Safety in Use - Approved Document A Energy Economy and heat retention - Approved Document L Durability serviceability and identification Validity This certificate was first issued on 11 th June 2013 and is valid until 13 th October Issue Dated 14 th October 2014

2 This is an assessment of various Rockwool External Thermal Insulation Composite Systems (ETICS) with rendering, intended for use as external thermal insulation of buildings. The ETICS are mechanically fixed to a masonry wall and are suitable for use on new and existing construction and satisfy the functional requirements of Building Regulations. Documents provided for RD included Rockwool façade standard details, Ceram hygrothermal test reports & pull through testing of fixings into mineral fibre insulation, Exova Warrington fire test reports, BuildDesk U value calculations & condensation risk analysis, Draft European Technical Approval. The systems are under consideration for a European Technical Approval (draft stage) and information has been provided to demonstrate essential requirements of ETAGs are achievable. 1 The systems are non-loadbearing. The systems are mechanically fixed to masonry or concrete substrate. In most cases adhesive is also incorporated to supplement the fixing (design to be agreed on a case by case basis ). Wind load suction calculations to be provided to confirm fixing required. Pull out tests to be carried out for each project in accordance with ETAG 014. Example of test result provided. 2 No effect on external flame spread or unprotected areas. Fire test reports provided demonstrate the systems achieve European class B,s1,d0. Rockwool are undertaking further tests to improve performance ( B to A2 ). 3 When used over existing construction the systems provide a degree of resistance to precipitation and wind driven spray. When incorporated in new construction the complete wall should be designed to resist precipitation. 4 Surface and interstitial condensation risk analysis provided with the example U Value calculations; this will need to be verified for alternative constructions. 5 Extract fan ductwork will need to be extended. 6 Retro fit boiler flue to be extended by a competent person in accordance with ADJ. 7 Example calculations submitted to demonstrate limiting U values of 0.28 and 0.3 W/m2K can be achieved. Calculations for other U values to be provided for alternative construction. 8 All installers are trained by Rockwool technicians and receive a card to confirm that they have been trained. Rockwool technicians monitor the installer and the work in progress to confirm in accordance with guidelines. 9 Appropriate thermal analysis will be provided in each instance to demonstrate continued compliance with Approved Document L 2013.

3 LABC consider that, REDArt Silicone, will meet the functional requirements of the Building Regulations (listed below) if the criteria detailed in this certificate are met; The Building Regulations 2010 (as amended) England & Wales Regulation 7 AD A AD B AD C AD F AD J AD L Materials and workmanship The products are acceptable. Structure Fire Safety Site preparation and resistance to contaminants and moisture Ventilation Combustion appliances and fuel storage systems Conservation of fuel and power The thermal insulation performance of this system should be considered in the context of the contribution made to the overall performance of the wall. The Building Regulations 2010 (as amended) England AD L Conservation of fuel and power The thermal insulation performance of this system should be considered in the context of the contribution made to the overall performance of the wall. The Building Regulations 2010 (as amended) Wales AD L Conservation of fuel and power The thermal insulation performance of this system should be considered in the context of the contribution made to the overall performance of the wall. The Building (Scotland) Regulations 2004 (as amended) If you would like to discuss a specific use of the product in Scotland it will require an additional assessment under the Scottish Building Regulations and accordingly you should contact the LABSS STAS Administrator at

4 LABC Warranty The use of the REDArt Silicone System has not been assessed to meet the requirements of the LABC Warranty Technical Manual. If you would like to discuss a specific use please make an enquiry to technical.services@labcwarranty.co.uk Rockwool Façade Systems Standard Details RWSD (00) Rockshield RWSD (00) fixing pattern for all building types RWSD (00) fixing pattern for 2 storey buildings - option 1 RWSD (00) fixing pattern for 2 storey buildings - option 2 RWSD (00) fixing pattern for 5 storey buildings - option 1 RWSD (00) fixing pattern for 5 storey buildings - option 2 RWSD (00) fixing pattern for 8 storey buildings - option 1 RWSD (00) fixing pattern for 8 storey buildings - option 2 RWSD (00) stress patches to openings RWSD (21) base track detail - type 1 RWSD (21) base track detail - type 2 RWSD (21) base track detail - extended RWSD (21) base track detail below dpc RWSD (21) base track detail above cut brickwork RWSD (21) stop end detail - vert full depth profile RWSD (21) stop end detail - vert corner bead embedded RWSD (21) stop end detail - vert corner bead exposed RWSD (21) stop end detail - internal corner type 1 RWSD (21) stop end detail - internal corner type 2 RWSD (21) stop end overhang detail - corner bead embedded RWSD (21) stop end overhang detail - corner bead exposed RWSD (21) movement joint - horizontal - full system type 1 RWSD (21) movement joint - horizontal - full system type 2 RWSD (21) movement joint - vertical - system type 1 RWSD (21) movement joint - vertical - system type 2 RWSD (21) movement joint - vertical - internal corner detail RWSD (21) definition joint detail RWSD (21) decorative horizontal finish change RWSD (21) colour change - thin coat render RWSD (21) penetration detail - boiler flue - overflow RWSD (21) penetration detail - retro fit boiler flue RWSD (21) penetration detail - air brick detail RWSD (21) penetration detail - vertical access detail RWSD (21) penetration detail - conduit housing detail RWSD (21) penetration detail - lightning conductor detail RWSD (21) penetration detail - surface fixing detail RWSD (21) penetration detail - post fix anchor point detail RWSD (21) penetration detail - utility meter box detail RWSD (27) pitched roof - eaves detail type 1

5 RWSD (27) pitched roof - eaves detail type 2 RWSD (27) pitched roof - verge flashing trim detail RWSD (27) flat roof - perimeter edge detail RWSD (27) flat roof - base track detail over RWSD (27) roof - coping detail RWSD (31) jamb - embedded corner bead - insulated reveal RWSD (31) jamb - embedded corner bead - uninsulated reveal RWSD (31) jamb - exposed corner bead - insulated reveal RWSD (31) jamb - exposed corner bead - uninsulated reveal RWSD (31) jamb - surround detail - embossed - insulated reveal RWSD (31) jamb - surround detail - embossed - uninsulated reveal RWSD (31) jamb - surround detail - flat - insulated reveal RWSD (31) jamb - surround detail - flat - uninsulated reveal RWSD (31) jamb - chamfered reveal to opening detail RWSD (31) cill detail - standard RWSD (31) cill detail - extended over cill - concrete RWSD (31) cill detail - extended over cill - upvc RWSD (31) cill detail - metal 2 part cill extension - concrete RWSD (31) cill detail - metal 2 part cill extension - upvc RWSD (31) cill detail - metal under cill - concrete RWSD (31) cill detail - metal under cill - upvc RWSD (31) head - flush window - embedded corner bead detail RWSD (31) head - flush window - exposed corner bead detail RWSD (31) head - standard - embedded corner bead - insulated reveal RWSD (31) head - standard - embedded corner bead - uninsulated reveal RWSD (31) head - standard - exposed corner bead - insulated reveal RWSD (31) head - standard - exposed corner bead - uninsulated reveal Ceram Test Reports (QT22724/1/SL)/Ref 2A - Hygrothermal Testing of Rockwool MineralWool Insulation with REDArt Silicone + and REDArt Granite Finish (QT22724/1/SL)Ref.7A -Water Vapour Permeability of Rockwool REDArt Silicone+ Render System to BS EN ISO 7783: 2011 in accordance with ETAG004: (QT22329/1/SL)/Ref Pull Through Testing of Fixings into Mineral Fibre Insulation Exova Warringtonfire Test Reports BS EN 13823: REDArt Silicone BS EN ISO : REDArt Silicone Example U Value calculations & condensation risk analysis NCRB LABC Approval - REDArt Silcone NCRB LABC Approval - REDArt Silcone Rockwool UK Draft ETA

6 Rockwool 1 Wern Taw Pencoed Bridgend South Wales CF35 6NY Tel: Systems.solutions@rockwool.co.uk Web: