S 01 Modules WC I-IlI

Size: px
Start display at page:

Download "S 01 Modules WC I-IlI"

Transcription

1 S 01 Modules WC I-IlI GB Installation instructions

2 GB S 01 Contents 1 Introduction... 4 About these instructions... 4 Explanation of the symbols and signal words used... 4 Target group... 4 HEWI Support... 4 Up-to-date information Product description... 6 Purpose and use... 6 Structure and function... 6 Versions... 7 Assembly principle... 8 S 01 consists of two sets of wall installation and module... 8 Detailed information Intended use Area of use Condition of the product Ambient conditions Safety Scope of supply and installation tools Planning information Installation Overview Set 1 Install prewall Set 2 Install functional elements Dismentling Note Maintenance Fill toilet roll holder Fill spare roll holder Clean toilet brush container Remove toilet brush and spare roll holder container Install toilet brush and spare roll holder container Change brake setting for support with lift-up feature Cleaning and maintenance Disposal Electronic components Product packaging HEWI 11/2013

3 S 01 GB 12 Product specification...41 Intended use...41 Technical data /2013 HEWI 3

4 GB S 01 1 Introduction About these instructions These instructions contain important information on the installation of HEWI S 01 WC modules. Carefully read through the instructions before starting the installation work and putting into service. Keep these instructions and distribute to appropriate personnel. Explanation of the symbols and signal words used WARNING! (1) (2) (3) Indicates hazards which could result in severe or fatal injuries. Assemblies that belong to the package Individual components Order of installation Target group Faultless, safe function of the WC modules depends to a large extent on proper installation. These instructions are therefore directed at trained installation engineering or building services personnel or people with comparable training. HEWI Support If you have any questions which are not answered by the information provided in these instructions, please contact HEWI Heinrich Wilke GmbH Support Postfach 1260 D Bad Arolsen Tel.: Fax: support@hewi.de 4 HEWI 11/2013

5 S 01 GB Up-to-date information All information about the product, images, dimensions and versions is upto-date and correct at the time of production. We reserve the right to make changes to our products without notice due to technical progress and the resulting continuous improvement process. The current version of these instructions and further information is also available on our internet site Dated 11/ /2013 HEWI 5

6 GB S 01 2 Product description Purpose and use The HEWI S 01 WC module is a dry walling installation system, which integrates various WC functions and features in one complete system. It is based on a standard prewall system and can be combined with normal commercial, wall-hung WCs. Structure and function The WC module has a flat front and contains the following functional elements, either to fold-out/down or integrated in the surface: A B C D E Support with lift-up feature (depending on version) Toilet roll holder Toilet brush Spare roll holder Electronic flushing mechanism with near field detection 6 HEWI 11/2013

7 S 01 GB Versions The following versions of the WC module are available. Name/Description Art. No. Description Drawing WC module I S Without support rail with liftup feature WC module II S Support rail with lift-up feature on one side (left/right) WC module III S Support rail with lift-up feature on both sides 11/2013 HEWI 7

8 GB S 01 Assembly principle S 01 consists of two sets of wall installation and module Set 1 - Prewall installation (construction phase) 8 HEWI 11/2013

9 S 01 GB Set 2 Module with functional elements (completion) Detailed information Further information on the product is given in Section 6 and /2013 HEWI 9

10 GB S 01 3 Intended use Area of use The WC module is suitable for installation in dry walling floor and ceiling rails (to be provided on site) or for mounting on floors and walls. The floor, ceiling and wall fixing materials are designed for concrete and solid sand-lime blocks. The relevant specifications and guidelines of all trades involved must be taken into account. Condition of the product The WC module may only be used if it is in faultless technical condition. Independent modifications and changes to the product are not allowed. Ambient conditions The electrical connections above the module required for the control components must be located at a minimum height of 2250 mm, measured from the finished floor level (OKFFB). 4 Safety The following and all other safety instructions in this document must be noted and followed before use! HEWI does not accept any liability whatsoever for injuries or damage to property that result from disregarding these instructions! WARNING! Exposed, live cables. Risk of electric shock. Improper connection of the electrical components can result in health damage. Note and comply with the following instructions: Work on the electrical components may only be carried out if they have been disconnected from the power supply. Only use components supplied by HEWI. 10 HEWI 11/2013

11 S 01 GB 5 Scope of supply and installation tools Scope of supply The scope of supply includes all parts required for installation of the WC module. The following are to be provided on site: 75 mm dry walling floor and ceiling rail, insulation tape WC Installation tools required 11/2013 HEWI 11

12 GB S 01 6 Planning information The system is suitable for room heights, including finished floor build-up mm For details of connection sheathing/panels, see drywalling on page 22 Key OKFFB = finished floor level OKRFB = unfinished floor level Prewall installation Sketch Dimensions Note: free-standing (independent) installation possible if necessary, can be installed with wall fixing Dimension a= mm Dimension b= mm ensure adequate space for pipes, etc. In niches and corners, leave at least 50 mm space at the side * max. space for pipes, etc. Drain height ca. 285 mm OKFFB Inlet height ca. 420 mm OKFFB 12 HEWI 11/2013

13 S 01 GB Modul Sketch Dimensions Note: direct stringing of the modules is not possible. Minimum distance between the modules is 75 mm 11/2013 HEWI 13

14 GB S 01 7 Installation Overview The installation is divided into the following activities: Install Set 1 prewall Install Set 2 functional elements 7.1 Set 1 Install prewall Proceed as follows: Pull-out module is made up, among other things, of the following components: Stillage Middle section Middle section, cistern Side section, left Side section, left with mounting foot Side section, right Side section, right with mounting foot Fixing bracket 14 HEWI 11/2013

15 S 01 GB Wooden sheating Middle section Side section, left Side section, right Pack contents Fixing material, floor and ceiling Fixing material, wall mounting 11/2013 HEWI 15

16 GB S 01 Assembly of slide blocks WC locator HEWI power supply unit Geberit control installation kit Fixing material, wooden sheathing Installation Instructions 16 HEWI 11/2013

17 S 01 GB Installation of pull-out module 1 Stick insulating tape onto dry walling floor (1) and ceiling rail (2), 2 align and install rails Insert pull-out module, middle section into the floor rail 3 Fixing feet (3) (adjustable height mm from finished floor level (OKFFB)) push into the ceiling rail (2). Use the spirit level (4) to align the pullout module part and fix in place with the locking screws (5) 11/2013 HEWI 17

18 GB S 01 4 Set the pull-out module, cistern at the marked height OKFFB 385 mm 5 Place the cistern part in the pullout module part and use screws to position. do not yet screw on, not until Step 6 6 Fix pull-out module, side section, left and side section, right at the side in case of module string and niche installations, Step 6 and 7 must be carried out in one installation step 18 HEWI 11/2013

19 S 01 GB 7 Insert pull-out module part and in the floor rail and push the fixing feet (1) into the ceiling rail. Use the spirit level (2) to align and the locking screws (3) to lock the position, then tighten the screws 8 Fasten frame If necessary, wall fixing is possible using angle bracket part with sound isolation (blue rubber element) 11/2013 HEWI 19

20 GB S 01 9 Install locating pins 10 Position power supply unit for HEWI WC sensor (1) and Geberit motor control (2) on the upper crossmember and prepare cable for further use. 20 HEWI 11/2013

21 S 01 GB Installation of wooden planking 1 Use the countersunk screws (1) supplied to fix the wooden sheathing part,and onto the frame yet do not screw on Use the wooden batten (2) to align the wooden sheathing with each other and screw tight Additionally fix with the wing screws. 11/2013 HEWI 21

22 GB S Drywalling 1 HEWI S 01 Wooden sheathing 2 Wooden sheathing, provided on site by customer, gypsum board 12.5 mm 3 Wall covering, provided on site by customer, e.g. gypsum board sheathing 12,5 mm, tiles < 12,5. mm must be flush with. 4 HEWI S 01 Front panel, acrylic glass at join with tile 22 HEWI 11/2013

23 S 01 GB 5 11/2013 HEWI 23

24 GB S Set 2 Install functional elements Proceed as follows: Module consists of inter alia the following components: Functional elements module S module S module S Toilet brush 1x 1x 1x Toilet roll holder and spare roll holder 1x 1x 1x Lift-up support - 1x 2x 24 HEWI 11/2013

25 S 01 GB Front panel Element module S module S Module S x 1x 1x 1x 1x 1x 2x 1x - - 1x 2x 1x 1x 1x 2x 2x 2x 11/2013 HEWI 25

26 GB S 01 Pack contents Geberit Bearing block Symbol set 26 HEWI 11/2013

27 S 01 GB Sealing strips and sensor 1 Cut the sealing strips to the required length and insert, without gaps, in the dust-free grooves provided. (1) 1x 892 mm (2) 1x 496 mm (3) 2x 192 mm (4) 2x 1992 mm 2 Bearing block install Geberit motor and connect Geberit motor connection, see separate installation instructions 11/2013 HEWI 27

28 GB S 01 3 Fix sensor and earthing cable to the angle plate (1). Fix angle plate onto bearing block of the cistern (2). The front surface of the sensor must be flush with the wooden sheathing in the same plane! Connection: a) WC sensor b) Bearing block Geberit c) Power supply unit HEWI d) Power supply unit Geberit Connect the sensor, see separate installation instructions Functional elements 1 Fix arm of support with lift-up feature onto the platform provided With or without arm, depending on the version. Use cup springs in opposite directions. Adjust brake, see page HEWI 11/2013

29 S 01 GB 2 Position functional elements flush on the wooden elements and on the seals and fix. With or without support with liftup feature housing, depending on the version The functional elements must not rest on the seals Thin-walled surfaces. Risk of stress whitening.) Use cordless screwdriver at lowest speed level only Do not screw in screws too tight. 11/2013 HEWI 29

30 GB S 01 3 Align and fix supports with lift-up feature Front panel 1 Use magnets or click-stop points to fix fronts in the order given on the right. Recommended installation order: 1, 2, 3, 4, 5, 6 do not use silicone! Should it be necessary to use only neutral crosslinked silicone 30 HEWI 11/2013

31 S 01 GB 2 3. The positioning aids supplied can be used to align the fronts, and /2013 HEWI 31

32 GB S Wc ceramics 1 Install WC (to be provided on site by customer) Note and follow the separate installation instructions of the manufacturer Symbol 1 The minimum bonding temperature is +8. The curing time is 78h! 1. Remove contamination such as dust, grease, etc. from the surface before gluing! 2. Pull off paper 3. Use the positioning marks to position the release liner at the top edge (flush symbol bottom edge) of the acrylic glass front 4. Rub on symbol 5. Pull off the release liner with positioning marks Example of the WC brush 2 32 HEWI 11/2013

33 S 01 GB 8 Dismentling Note Dismantle in the reverse order. Therefore, follow the figures in section 7. 9 Maintenance 9.1 Fill toilet roll holder /2013 HEWI 33

34 GB S Fill spare roll holder HEWI 11/2013

35 S 01 GB 9.3 Clean toilet brush container /2013 HEWI 35

36 GB S Remove toilet brush and spare roll holder container HEWI 11/2013

37 S 01 GB Install toilet brush and spare roll holder container /2013 HEWI 37

38 DE S Change brake setting for support with lift-up feature turn in direction a to increase braking force, turn in direction b to reduce braking force, 38 HEWI 11/2013

39 S 01 GB /2013 HEWI 39

40 DE S Cleaning and maintenance CAUTION! Material damage due to incorrect cleaning Incorrect cleaning can cause attack and damage to the surfaces: Do not use alkali, acidic or chlorine-containing cleaning agents. Do not use cleaning agents containing abrasive additives. Do not use abrasive instruments, e.g. brushes. Do not rub dry surfaces. Acrylic glass has a pore-free surface, to which dirt hardly sticks. Wipe down surfaces with water, a soft cloth or a sponge. Use a standard commercial cleaning agent for thorough cleaning. 11 Disposal Electronic components Electronic components must be disposed of in a communal collection point for hazardous electrical waste. Product packaging The product packaging must be disposed of through the local household or paper waste collection facility. 40 HEWI 11/2013

41 S 01 GB 12 Product specification Intended use The medical device "S 01" support with lift-up feature supports disabled people or people with a handicap and helps them to sit or stand/straighten up, e.g. on the toilet. The "S 01" support with lift-up feature is used to provide safety and space for other persons. Technical data Visible surface Functional elements Supply voltage of the control components Seal Sound insulation Maximum loading capacity of the support with lift-up feature Acrylic glass, thickness = 6 mm Polystyrene 12 V Flat seal (included in the scope of supply) Sound insulation (decoupling) of all pipes and the installation element from the structure 100 kg 11/2013 HEWI 41

42 GB S HEWI 11/2013

43 S 01 GB 11/2013 HEWI 43

44 Deutschland HEWI Heinrich Wilke GmbH Postfach 1260 D Bad Arolsen Telefon: Telefax: MS01.06GB 10/2013