CBUCK Engineering. Evaluation Report FW-1025 Panel with Optional Seamlock Metal Roof Assembly

Size: px
Start display at page:

Download "CBUCK Engineering. Evaluation Report FW-1025 Panel with Optional Seamlock Metal Roof Assembly"

Transcription

1 Evaluation Report FW-1025 Panel with Optional Seamlock Metal Roof Assembly Manufacturer: 1720 Maury Road Houston, TX (800) for Florida Product Approval # FL R2 Florida Building Code 6th Edition (2017) Method: 1 - D Category: Structural Components Sub - Category: Roof Deck Product: Material: Panel Thickness: Support: FW-1025 Roof Panel Aluminum.032 &.040 Steel Purlins Prepared by: James L. Buckner, P.E., S.E.C.B. Florida Professional Engineer # Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No FW1025-AP-ER (Revises Report No FW1025-AP-ER, FL R1) Facsimile of digital copy signed by James L. Buckner, P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G Contents: Evaluation Report: Pages :48:53-04'00' CBUCK, Inc. dba Phone: (561) cbuck@cbuckinc.net Website: Business: 1374 Community Dr., Jupiter, FL Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062

2 Page 2 of 7 Manufacturer: Product Name: 1720 Maury Road Houston, TX (800) FW-1025 Panel with Optional Seamlock Product Category: Structural Components Product Sub-Category Roof Deck Product/System Description: Product Assembly as Evaluated: FW-1025 Panel Structural aluminum roof panels with concealed fasteners, a flush seam and interlocking seam edge with optional seam lock feature designed to resist panel disengagement. Panels are attached to steel supports with screws. Refer to Page 4 of this report for product assembly components/materials & standards: 1. Roof Panel 2. Fasteners 3. Insulation (Optional) Support: Slope: Type: Steel Purlins (Design of steel purlins and its attachment to support framing is outside the scope of this evaluation.) Description: 16 Gauge minimum Yield Strength: 50 ksi minimum Minimum slope shall be in compliance with FBC Chapter 15 based on the type of roof covering, applicable code sections and in accordance with manufacturer s recommendations. Performance: Wind Uplift Resistance: Design Uplift Pressure: (Refer to Table A attachment details herein) Refer to Table A

3 Page 3 of 7 Performance Standards: Standards Equivalency: Code Compliance: Evaluation Report Scope: Limitations and Conditions of Use: The product described herein has demonstrated compliance with: TAS Standard Requirements for Metal Roofing Systems ASTM E Test Method for Structural Performance of Sheet Metal Roof and Siding Systems By Uniform Static Air Pressure Difference The ASTM E standard version used to test the evaluated product assembly is equivalent with the prescribed standards in ASTM E adopted by the Florida Building Code 6th Edition (2017). The product described herein has demonstrated compliance with Florida Building Code 6th Edition (2017), Section This product evaluation is limited to compliance with the structural requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G Diaphragm and axial load capacity is outside the scope of this evaluation. Scope of Limitations and Conditions of Use for this evaluation: This evaluation report for Optional Statewide Approval contains technical documentation, specifications and installation method(s) which include Limitations and Conditions of Use throughout the report in accordance with Rule 61G Per Rule 61G , the Florida Building Commission is the authority to approve products under Optional Statewide Approval. Option for application outside Limitations and Conditions of Use Rule 61G (1)(e) allows engineering analysis for project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code. Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. All metal components and fasteners shall be corrosion resistant in accordance with applicable sections of FBC, including but limited to Sections , and Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties)

4 Page 4 of 7 Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through By UL, LLC. Components/Materials (by Manufacturer): Roof Panel: Material: Thickness: Panel Width: Rib Height: Alloy Type: Corrosion Resistance: Fastener: Type: Size : Corrosion Resistance: Standard: Berridge FW-1025 Panel Aluminum Or /4 Coverage 1-1/ H14, in compliance with ASTM B 209 In compliance with FBC Section Hex-Washer Head Self-Drilling Screw #12-14 x 1-1/4 with 5/8 washer head Per FBC Section and Per and SAE J Components& Materials: (by Others) Insulation (Optional): Type 1: Density: Compressive Strength: Thickness: Type 2: Thickness: Rigid Insulation Board 2.25 pcf (lbs/ft 3 ) min. 20 psi min. 3 (max.) Compressible Blanket Insulation 6 max. before compression Insulation Notes: Rigid Insulation shall meet minimum density OR compressive strength. Insulation shall comply with FBC Section When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/4.

5 Page 5 of 7 Installation: Installation Method: (Refer to TABLE A below and drawings in the back of this report.) Purlin Spacing: Refer to TABLE A Below Two (2) fasteners (at each purlin intersection) Rib Interlock: Panel ribs shall be fully engaged to form an integral interlock. Minimum fastener penetration thru bottom of support, 3 /4. TABLE A ALLOWABLE LOADS # PANEL MAX. SUPPORT SPAN THICKNESS SPACING CONDITION FASTENER # OF SCREWS DESIGN PRESSURE (PSF) (2-0 ) TRIPLE # (2-0 ) TRIPLE # NOTES: Allowable design pressure(s) for allowable stress design (ASD). Fastener Attachment to Steel Supports May Be Designed By A Qualified Design Professional As Required By The Florida Building Code For Site Specific Projects. Diaphragm and axial load capacity are not included in this evaluation Install the FW-1025 roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). The installation method described herein is in accordance with the scope of this evaluation report. Referenced Data: 1. TAS Uplift Test (Per ASTM E ) By Force Engineering & Testing Inc., Inc. Report # T-14 H, I, Report Date: 7/25/14, Test Specimen(s) # H (0.032 ) Test Specimen(s) # I (0.040 ) 2. Quality Assurance By UL, LLC. 3. Equivalency of Test Standard Certification By James L. Buckner, 4. Certification of Independence By James L. Buckner,

6 Page 6 of 7 Installation Method FW-1025 with Seam Lock Roof Panel attached to Steel Purlins 10.25" 1.46" 1.16" Typical Panel Profile FW-1025 Panel Seamlock Detail View

7 Page 7 of 7 Installation Method FW-1025 with Seam Lock Roof Panel attached to Steel Purlins 10-1/4" "FW-12" Roof Panel Two #12-14 x 1-1/4 HWH Self-Drilling Screws Steel Support Typical Panel Assembly Section View TABLE A ALLOWABLE LOADS # PANEL THICKNESS MAX. SUPPORT SPACING SPAN CONDITION FASTENER # OF SCREWS DESIGN PRESSURE (PSF) (2-0 ) TRIPLE # (2-0 ) TRIPLE #