axolute etèris Contents etèris

Size: px
Start display at page:

Download "axolute etèris Contents etèris"

Transcription

1 etèris Contents axolute etèris excellent dedicated installation system 164 the new boxes 165 the new supports 166 the new cover plates 167 installation procedures module boxes modularity

2 axolute etèris: excellent dedicated installation system new specific components: new flush mounted and plasterboard boxes new supports new cover plates to be used with a new range of accessories, necessary for completing the various installation stages. New boxes traditional installation procedures the installation procedures are the same as for traditional systems New supports AXOLUTE devices already listed in the catalogue New cover plates axolute etèris can be used to install all the modular axolute devices listed in the catalogue. 164 Example with 1 module device Example with 1 and 2 module devices Example with 2 and 3 module devices

3 axolute etèris: the new BoXes new dedicated BoXes: 2 new modular constructions (2 and 8 modules) deeper: for minimum protrusion of the switch from the wall same ease of installation as for traditional residential lines masonry plasterboard/dry partition walls Deeper than traditional boxes Screw sockets reinforced with steel inserts etèris Mortar protection cover included (for flush mounted boxes) The covers are fitted with appropriate spirit level housings. For masonry Walls 2 modules 8 modules For plasterboard Walls (10 to 45 mm thick boards) 2 modules 8 modules Etèris boxes are deeper than standard boxes. When designing the system, ensure that their positioning is adapted to the type of wall. E.g. with standard partition walls with thicknesses of approx. 10 cm, it will not be possible to install 2 boxes opposite to each other (one each side of the wall) because the overall space required of 12 cm would exceed the thickness of the wall. 165

4 axolute etèris: the new supports With etèris, two supports are enough for obtaining all possible combinations. 2 modules Knockouts: to be removed for plasterboard installations. 8 modules For 1 and 2 module devices For 1 to 4 module devices embossed arrows to indicate the correct installation direction. like the traditional axolute supports, also the etèris supports are fitted with a clear cover, for the protection of devices during masonry operations. 166

5 axolute etèris: the new CoVeR Plates 2 formats 3 finishes (white, tech, anthracite the same as axolute devices) small Format large Format only 2.5 mm thick etèris 2 modules 4 modules 8 modules Touch Screen and Video Display cover plate The use of the insulating under cover plate is compulsory 4 and 8 module modules have a separate insulating under cover plate, to assure the safety of the switch also without cover plate. Removing the cover plates to remove the fitted etèris cover plates, use the appropriate suction pads accessory, item h4802ky. Press the suction pads accessory on the fitted cover plate until complete adhesion. Pull to completely dislodge the cover plate from its housing. 167

6 axolute etèris: installation PRoCedURes installation in masonry walls the masonry operations to fix the box to the masonry wall are extremely important and ensure optimum visual result. 2 1 insert the box in the wall cavity. Use the appropriate accessory (item 502WBi) to ensure perfect level. Plaster the wall and apply the setting coat. once the wall has been finished, the box must not protrude from the wall. 3 Resolve any wall imperfections around the box using the appropriate cover (item 502CW or item 528CW). 4 Fix the support to the box. if necessary, cover using the clear protection. 5 Completed switch. 168 Note: the above procedures apply both to 2 module and 8 module boxes

7 Covered walls When installing etèris on covered walls (e.g. tiled walls) it will be necessary to proceed as shown below, after repeating steps 1 and 2 described above. 3 4 etèris after removing the mortar protection cover, fit the appropriate wall coverings cover (item 502CW or item 528CW). Fit the wall covering. Use the cover as a template to precisely cut through the tiles. 5 Wall covering fitting completed. 6 Fix the support to the box. the support shall be fitted on top of the wall covering. if necessary, cover using the clear protection. 7 Completed switch. 169

8 axolute etèris: installation PRoCedURes installation in plasterboard walls 1 2 adhesive labels to help cutting the plasterboard. supplied with 2 module and 8 module boxes. 3 insert the box in the recess created and secure using the appropriate straps. Prepare the support by removing the knockout sections. 4 5 Fix the support to the box. Completed switch. if necessary, cover using the clear protection. 170 Note: the above procedures apply both to 2 module and 8 module boxes

9 2 module BoXes modularity Cover plates joined together depending on needs and design requirements, etèris can be used to create a switch/ socket units with several 2 module boxes joined together. once the installation is completed, the cover plates will be perfectly aligned and joined. Example of horizontal configuration with 3 cover plates Example of vertical configuration with 2 plates etèris JoininG the boxes together this operation is the same both for masonry and plasterboard boxes, using the appropriate coupler (item 502Wa). the boxes will be perfectly joined and level with each other, making the subsequent steps much easier. Coupler (item 502WA) Cable passage hole Cable passage knockout to be removed Boxes joined together, with the cable passing through the coupler. 171

10 2 module BoXes modularity installation in masonry walls 1 after inserting the boxes in the wall, make sure that they are perfectly level using the appropriate accessory (item 502WBl). 2 Plaster the wall and apply the setting coat. once this operation is completed, the boxes must not protrude from the wall. aligning and FiXinG the supports after removing the masonry protection covers and resolving any wall imperfection using the appropriate accessory, fit the supports without tightening the screws. Use the template, item 502Wd and the spirit level, to align the supports. secure in position by tightening the screws. after securing the supports finish assembling the switch using the normal procedure. Screw not tightened Before tightening the screws correctly position the template, and align the first two supports using the spirit level. Tighten the screws. Align and the secure the remaining supports

11 installation in plasterboard walls 1 Empty gaps to be filled using filler. after cutting through the board and fixing the boxes, fill any gaps between the boxes using an appropriate filler. etèris 2 Prepare the support by removing the knockout sections. aligning and FiXinG the supports Fit the supports in place without tightening the screws. Use the template, item 502Wd and the spirit level, to align the supports. secure in position by tightening the screws. after securing the supports finish assembling the switch using the normal procedure. Screw not tightened 3 4 Before tightening the screws correctly position the template, and align the first two supports using the spirit level. Tighten the screws. Align and the secure the remaining supports 173

12 2 module BoXes modularity separate cover plates in addition to the joined installation, several switches may be positioned at a distance from each other, both horizontally and vertically, on all types of walls. Vertical configuration Horizontal configuration 27 mm 27 mm Using the BTicino accessories, after installation the cover plates will be at a distance of 27 mm from each other 27 mm masonry Walls installation at a precise distance is made possible using the appropriate distancing module. this module can be found in our catalogue as an accessory for other residential series, with item no. 503ed. note the installation operations are the same as described for joined or individual boxes. plasterboard Walls the pre-spaced adhesive labels supplied with the boxes must be used. note once the plasterboard wall has been cut, the installation procedures are the same as described for individual boxes. distancing module (item 503ED) Adhesive label: remove the correct plasterboard section based on the number of boxes to fit. 174 Note: Item 503ED can also be used with 8 module boxes.

13 etèris Contents axolute etèris CataloGUe 176 installation diagrams 178 Cover plates range

14 axolute etèris CataloGUe touch screen Item HW4684 Description Monobloc Etèris Touch Screen. It can only be installed on item 528W (masonry) and item PB528W (plasterboard) boxes. Room control to be installed where there are several MY HOME functions. Interface to control scenarios, lighting, automation, Burglar-alarm, temperature control and energy management. HW video display etèris Item Description Monobloc Etèris video display. It can only be installed on item 528W (masonry) and item PB528W (plasterboard) boxes. Cover plates items HW4826HC, HW4826HS, HW4826HD are also required. The functions are the same as the video displays already listed in our catalogue: Item , , White front cover for Etèris video display, item Tech front cover as above Anthracite front cover as above etèris video display assembly Etèris video display the video display item must be completed with one of the 3 front covers. Anthracite front cover Tech front cover 176 White front cover

15 supports H4702W Item H4702W H4728W Description 2 module support with clear protection. It can be used both with masonry box, item 502W, and with plasterboard box, item PB502W. 8 module support with clear protection. It can be used both with masonry box, item 528W, and with plasterboard box, item PB528W. 502W H4728W 528W boxes Item 502W 528W PB502W PB528W Description 2 module flush-mounted box for masonry walls with mortar protection cover supplied as standard. 8 module flush-mounted box for masonry wall with mortar protection cover and internal partition supplied as standard. 2 module flush-mounted box for plasterboard walls with fixing straps supplied as standard. 8 module flush-mounted box for plasterboard walls with fixing straps and internal partition supplied as standard. CataloGUe etèris PB502W PB528W accessories H4802KY 528CW 502WBL 502WD 502CW Item H4802KY Description Suction pads accessory for the removal of Etèris cover plates. 502WBL Spirit level holder with spirit level, for positioning of the boxes and correct supports alignment. 502CW 2 module cover to be used when positioning wall coverings around 2 module boxes. Also useful for dealing with any wall shaving mistakes. 528CW 8 module cover to be used when positioning wall coverings around 8 module boxes. Also useful for dealing with any wall shaving mistakes. 502WD Template for the alignment of 2 module supports in joined installations, or to mark the hole position on plasterboard walls. 502WA Coupler, used for coupling the boxes together: 2 modules for masonry and plasterboard walls, keeping the boxes perfectly joined and aligned. 503ED Box coupler for masonry walls (502W and 528W). On completion of the installation the cover plates will be at 27 mm distance from each other. 502WA 503ED Note: the codes in these pages are specific for AXOLUTE ETÈRIS. For all the codes of the installable products refer to the AXOLUTE catalogue sections. 177

16 axolute etèris installation diagram 2 and 4 modules Boxes supporting frames no. of modules Cover plates 502W (70.5X70.5x58) HW4802HC H4702W HW4802HS PB502W (70.5X70.5x58) 2 modules HW4802HD HW4824HC 528W (128.5x128.5x58) H4728W HW4824HS PB528W (116.5x116.5x58) 4 modules HW4824HD 178

17 8 modules, touch screen and Video display Boxes supporting frames no. of modules Cover plates 528W (128.5x128.5x58) HW4828HC CataloGUe etèris H4728W HW4828HS PB528W (116.5x116.5x58) 8 modules HW4828HD HW4684 HW4826HC 528W (128.5x128.5x58) HW4826HS PB528W (116.5x116.5x58) HW4826HD 179

18 axolute etèris CoVeR Plates RanGe White tech anthracite 2 modules HW4802HD HW4802HC HW4802HS 4 modules HW4824HD HW4824HC HW4824HS 180

19 White tech anthracite 8 modules HW4828HD HW4828HC HW4828HS CataloGUe etèris touch screen and Video display HW4826HD HW4826HC HW4826HS 181