1 145-0 SIGN SCHEDULE A1 A2 A3 B C D E F G B G F A1 INTERNALLY ILLUMINATED CHANNEL LETTERS INTERNALLY ILLUMINATED CHANNEL LETTERS INTERNALLY ILLUMINATED CHANNEL LETTERS D/F INTERNALLY ILLUMINATED MONUMENT SIGN STANDARD SWIVEL ARM CLEARANCE SIGN PROPOSED CANOPY-ORDER CONFIRMATION UNIT PROPOSED MENU BOARD SYSTEM D/F PAN-FACED DIRECTIONAL D/F PAN-FACED DIRECTIONAL A2 E D A3 G SCALE: 1/32 = R4

2 A1 A3 Scale: 3/32 = 1-0 Scale: 3/32 = R4

3 80-8 A Scale: 3/32 = Scale: 3/32 = R4

4 SLOAN LED LOW VOLTAGE LIGHTING SYSTEM U.L. LISTED - CLASS 2 - CONFORMS TO U.L N.E.C. 600 STANDARDS SQ. FT. 20 SQ. FT. 3-9 PMS# 485-C RED.040 ALUMINUM RETURNS (RED) 1" TRIM CAP SLOAN WHITE LED LIGHT MODULES 120V/12VDC POWER SUPPLY IN BOXES BEHIND WALL 14 AWL WIRING FROM POWER SUPPLY TO LED MODULES #278-0 SG RED ACRYLITE FACES 5" 2-0 A1 A2 A3 LETTER SET ELEVATION SQ. FT. TOTAL: QUANTITY: THREE (3) SETS REQUIRED COLOR SPECIFICATIONS RETURNS TO MATCH PMS# 485-C RED TRIM CAP 1 RED FACES: #278-0 SG RED ACRYLITE SCALE; 3/4 to 1-0 ELECTRICAL REQUIREMENTS Total: T.B.D. Amps (T.B.D.) 120V 20A Circuit Required. ALL BRANCH CIRCUITS SHALL BE DEDICATED TO SIGNS (INCLUDING GROUND AND NEUTRAL) AND SHALL NOT BE SHARED WITH OTHER LOADS. CONDUIT THRU WALL TO LETTERS BY SIGN INSTALLER ¼ WEEP HOLES IN BOTTOM OF LETTERS (2 MIN.) GALVANIZED OR STAINLESS STEEL TOGGLE BOLTS. IF WALL CONDITIONS ARE NOT CONDUCIVE TO TOGGLE BOLT MOUNTING, ALTERNATE MOUNTING METHODS WILL BE NEEDED. J-BOX BY OTHERS TYPICAL REMOTE L.E.D. CHANNEL LETTER SCALE: 3/4 to 1-0 GENERAL NOTES: 1.CONTRACTOR SHALL VERIFY WALL CONDITIONS IN THE FIELD. 2. TYPE, SIZE & NUMBER OF FASTENERS TO BE DETERMINED. 3.ALL BOLT TO BE DRILLED AND OR PUNCHED. 4. ISOLATE ALUMINUM FROM STEEL. CUSTOMER TO PROVIDE: ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUITS & FINAL CONNECTION TO EACH SIGN (WITHIN 5 FT.) TO BE BY CERTIFIED ELECTRICIAN: A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. Any deviation from the above recommendations may result in: 1. Damage to or improper operation of the sign(s). 2. Delays and additional costs. Notes: Certain electrical components of signs will fail prematurely if signs are not shut-off for a period of time, once, each day. For best performance, we recommend signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that will automatically shut-off the sign for a period of time, each day. Failure to do so will cause damage to the electrical components of the sign and will void the warranty. Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation with Federal Heath Sign Co. will void the warranty. INSTALLER IS RESPONSIBLE FOR: ELECTRICAL NOTES: 1. INSTALLATION OF THESE (ELECTRICAL) SIGNS SHALL CONFORM TO THE REQUIREMENTS OF ARTICLE 600 OF THE N.E.C., U.L. 48 AND / OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS R4

5 COLOR SPECIFICATIONS PMS 348-C GREEN PMS#9 YELLOW PMS#032 RED WHITE 4-2 B NOTE: FACE TO BE 2nd SURFACE MFR. AND INSTALL (1) D/F MONUMENT SIGN. ALUMINUM CABINET PAINT FINISH GREEN. INTERIOR FLUORESCENT LAMP ILLUMINATION CLEAR POLYCARBONATE FACES WITH SECOND SURFACE PAINTED GRAPHICS. RETAINER FRAME TO HINGE OPEN FOR ELECTRICAL SERVICE. ALUMINUM CABINET SURROUND, BASE AND TRIM WITH SMOOTH TEX-COTE FINISH. STANDARD INSTALL IS TO BE DIRECT PIPE EMBEDMENT INTO CONCRETE FOOTING PER FH ENGINEERING SPECS ½ THICK PVC DIMENSIONAL ADDRESS NUMERALS. PAINT FINISH BLACK. MANUFACTURING WILL PROVIDE A STUB PIPE WITH SIGN CABINETS ONLY IF O.A.H. (CABINET + STUB PIPE) DOES NOT EXCEED 9'-7" MAXIMUM SHIPPING HEIGHT RESTRICTIONS. ALL SUPPORTING STEEL, INCLUDING STUB PIPE, IF NOT INCLUDED WITH CABINET, TO BE SHIPPED TO INSTALLATION SITE BY AN OUTSIDE SUPPLIER OR BY THE INSTALLATION CONTRACTOR, AS DETERMINED BY PROJECT MANAGEMENT. B D/F INTERNALLY ILLUMINATED MONUMENT SIGN SCALE: 1 to 1-0 SIDE VIEW NOTE: UPON CUSTOMER ACCEPTANCE, FEDERAL HEATH ENGINEERING DEPARTMENT WILL PROVIDE FABRICATION DRAWINGS & ENGINEERED SEAL DRAWINGS IF REQUIRED THIS DRAWING IS FOR PRESENTATION ONLY NOTE: UPON CUSTOMER ACCEPTANCE, FEDERAL HEATH ENGINEERING DEPT. WILL PROVIDE FABRICATION DRAWINGS AND ENGINEERED SEAL DRAWINGS IF REQUIRED. THIS DRAWING IS FOR PRESENTATION ONLY CUSTOMER TO PROVIDE: ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUITS & FINAL CONNECTION TO EACH SIGN (WITHIN 5 FT.) TO BE BY CERTIFIED ELECTRICIAN: A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement. Any deviation from the above recommendations may result in: 1. Damage to or improper operation of the sign(s). 2. Delays and additional costs. Notes: Certain electrical components of signs will fail prematurely if signs are not shut-off for a period of time, once, each day. For best performance, we recommend signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that will automatically shut-off the sign for a period of time, each day. Failure to do so will cause damage to the electrical components of the sign and will void the warranty. Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation with Federal Heath Sign Co. will void the warranty. INSTALLER IS RESPONSIBLE FOR: ELECTRICAL NOTES: 1. INSTALLATION OF THESE (ELECTRICAL) SIGNS SHALL CONFORM TO THE REQUIREMENTS OF ARTICLE 600 OF THE N.E.C., U.L. 48 AND / OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS R4

6 FRONT ELEVATION C SIDE VIEW STANDARD SWIVEL ARM CLEARANCE SIGN / ONE (1) REQUIRED SCALE : 1/2" = 1'-0" R4

7 COLOR KEY P-2 CANOPY COVERINGS SIMULATED METAL ROOF TILES SPANISH GRAY P-3 SPRAYLAT PAINT (SEMI GLOSS) TO MATCH SW 6423 RYEGRASS (STUCCO FINISH) SPRAYLAT PAINT (SEMI GLOSS) TO MATCH SW 6379 JERSEY CREAM (STUCCO FINISH) T.B.D. CUSTOMER TO PROVIDE: (For New / Remodel Construction) ADEQUATE BEHIND THE WALL BACKING AND ACCESS AS REQUIRED TO INSTALL SIGNAGE. CUSTOMER TO FORWARD COPY OF FINAL APPROVED SIGNAGE DRAWINGS TO BUILDING SITE CONTACT SO THAT THESE PROVISIONS CAN BE MADE DURING CONSTRUCTION AND PRIOR TO SIGN INSTALLATION. ALL BRANCH (PRIMARY ELECTRICAL SERVICE) CIRCUITS & FINAL CONNECTION TO EACH SIGN (WITHIN 5 FT.) TO BE BY CERTIFIED ELECTRICIAN: A. All branch circuits for signs must be totally dedicated to signs (including dedicated ground and dedicated neutral per circuit). B. Sign circuits must not be shared with other loads such as lighting, air conditioning, and other equipment. C. Properly sized ground wire that can be traced back to the breaker panel must be provided. D. Number and size of circuits for each sign to meet Federal Heath Sign's requirement Any deviation from the above recommendations may result in: 1. Damage to or improper operation of the sign(s). 2. Delays and additional costs. 2 VENTS Notes: Certain electrical components of signs will fail prematurely if signs are not shut-off for a period of time, once, each day. For best performance, we recommend signs to be connected to an automatic controlling device such as an Energy Management System, Time Clock or Photo Cell that will automatically shut-off the sign for a period of time, each day. Failure to do so will cause damage to the electrical components of the sign and will void the warranty. Some dimming devices will also adversely affect sign electrical components, causing failure. Any dimming of the sign without consultation with Federal Heath Sign Co. will void the warranty. DOORS IN BACK INSTALLER IS RESPONSIBLE FOR: PROVIDING AND INSTALLING ALL COMPONENTS REQUIRED TO RUN SECONDARY WIRING (CONNECTORS, GTO CONDUIT, ETC.) TO BE DETERMINED BY LOCAL CODE AND SITE CONDITIONS. PROVIDING ALL NEEDED INSTALLATION HARDWARE AS DETERMINED BY LOCAL CODE AND SITE CONDITIONS. SEALING BUILDING PENETRATIONS WITH SILICONE TO PREVENT MOISTURE EXTERIOR LOCATIONS.. D SIDE VIEW ELEVATED MARKET CANOPY-ORDER CONFIRMATION UNIT ( 1 ) ONE REQUIRED SCALE: 1/2 to 1-0 COVER TO HINGE. ACCESS TO INTERIOR TO BE THRU DOORS IN BACK DOORS IN BACK R4

8 CABINET: ALUMINUM CONSTRUCTION PAINTED: SM6814S POWDER COAT BRONZE STIMPLE FINISH SUPPORTED ON A SINGLE STEEL POLE-BOTTOM OF SIGN IS NORMALLY 12 ABOVE GRADE. INTERNALLY ILLUMINATED W/ H.O. LAMPS. 82 MAIN MENU CABINET INDIVIDUAL COVER DOORS: PROTECT MENU FACES FROM THE ELEMENTS AND OPEN WIDE TO ALLOW EASY ACCESS TO FACES AND LAMPS. MENU FACES: EASILY REMOVED FROM CABINET FOR TRANSPARENCY CHANGES MAIN MENU CABINET TRANSPARENCIES: PROVIDED & LOADED BY: OTHERS A VERSION OF THIS MENU IS ALSO AVAILABLE W/ SPEAKER-IN-SIGN 12 E CORE MARKET MENU BOARD ELEVATION Quantity: One (1) required 44 8 CORE MARKET MENU BOARD SIDE VIEW ELECTRICAL INFORMATION: 8) F64T12CWHO LAMPS 2) ESB AMPS EA. TOTAL ELECTRICAL LOAD = 4.68 AMPS (1) 120V/20AMP CIRCUIT REQUIRED R4

9 /4 24 F D/F PAN-FACED DIRECTIONAL / ONE (1) REQUIRED / 2.0 SQ.FT. SCALE : 3/4" = 1'-0" /4 3-0 G D/F PAN-FACED DIRECTIONAL / ONE (1) REQUIRED / 2.0 SQ.FT SCALE : 3/4" = 1'-0" STANDARD INSTALL IS TO BE DIRECT PIPE EMBEDMENT INTO CONCRETE FOOTING PER FH ENGINEERING SPECS. MANUFACTURING WILL PROVIDE A STUB PIPE WITH SIGN CABINETS ONLY IF O.A.H. (CABINET + STUB PIPE) DOES NOT EXCEED 9'-7" MAXIMUM SHIPPING HEIGHT RESTRICTIONS. FRONT ELEVATION SCALE : 3/4" = 1'-0" SIDE VIEW ALL SUPPORTING STEEL, INCLUDING STUB PIPE, IF NOT INCLUDED WITH CABINET, TO BE SHIPPED TO INSTALLATION SITE BY AN OUTSIDE SUPPLIER OR BY THE INSTALLATION CONTRACTOR, AS DETERMINED BY PROJECT MANAGEMENT. NOTE: UPON CUSTOMER ACCEPTANCE, FEDERAL HEATH ENGINEERING DEPARTMENT WILL PROVIDE FABRICATION DRAWINGS & ENGINEERED SEAL DRAWINGS IF REQUIRED THIS DRAWING IS FOR PRESENTATION ONLY R4

10 TENANT PANEL TO BE ON WEST FACE SIDE ONLY V.O. H MULI-TENANT PYLON SIGN / SIGN PANEL 3/4 =1-0 MFR. AND INSTALL (1) CLEAR LEXAN PANEL WITH SECOND SURFACE PAINT DECORATION. YELLOW COPY OVER GREEN FIELD. FIELD VERIFY CUT SIZES. COLOR SPECIFICATIONS PMS 348-C GREEN PMS#9 YELLOW PMS#032 RED WHITE NOTE: FACE TO BE 2nd SURFACE