1 DESCRIPTION LIGHTLOCKS Fire Rated rchitectural Resins [FR] offer architects and designers more creative freedom to transform space in a variety of venues where fire rated materials are required for finish surfaces and decorative elements. Wall coverings, wall panels and wall partitions, as well as ceiling elements, can be luminous, colorful and exciting finishes for a wide variety of interior designs. PRODUCTS PRODUCT PPLICTION [FR] CLSS Palette #POLY-16FR Palette #POLY-8FR Palette #POLY-4FR Canvas #POLY-16CFR Canvas #POLY-8CFR Canvas #POLY-4CFR MTERILS THICKNESS 1/16 (1.5mm) 1/8 (3mm) 1/4 (6mm) 1/16 (1.5mm) 1/8 (3mm) 1/4 (6mm) Palette #CR-58FR crylic + MDF 5/8 (15mm) Palette #CR-34FR crylic + MDF 3/4 (19mm) Palette #CR-1FR crylic + MDF 1 (25mm) Classic #CR-58MFR crylic Mirror + MDF 5/8 (15mm) Canvas #CR-58CFR crylic + MDF 5/8 (15mm) Canvas #CR-34CFR crylic + MDF 3/4 (19mm) Canvas #CR-1CFR crylic + MDF 1 (25mm) Designer #POLY-2TFR Partition 1/2 (12mm) Designer #PETG-2TFR Designer #CR-2TFR Partition Partition Polyester - PETG crylic 1/2 (12mm) 1/2 (12mm) PLETTE: Opaque panels, custom colored on back CNVS: Opaque panels, digitally printed on back DESIGNER: Translucent panels, custom colored on back (See individual product specifi cation sheets and general technical manual for more details.) 1

2 PPLICTIONS Vertical thermoplastic resin for s: Full height sheets or cut to size and shape, up to 12 (3.65m) high x 5 (1.5m) wide. Use in corridors, entryways, concourses, classrooms, patient rooms, commercial buildings, stairwells, elevator cabs and anywhere a durable full height or wainscoting fi re rated Class or wall covering is required. Fasten to wall substrate with adhesive, mechanical fasteners or frames. Vertical thermoplastic resin for s: Full height assembled sheets or cut to size and shape, consisting of thermoplastic resin sheet laminated to FR MDF, up to 12 (3.65m) high x 5 (1.5m) wide. Use in corridors, entryways, concourses, classrooms, patient rooms, commercial buildings, stairwells and anywhere a durable full height or wainscoting fi re rated Class wall panel is required. Fasten to wall with mechanical fasteners, frames, wall cleats or Z clips. Vertical or horizontal thermoplastic resin for Partitions: Cut to size or shape sheets up to 12 (3.65m) long x 5 (1.5m) wide. Use in corridors, entryways, concourses, classrooms, patient rooms, commercial buildings, elevator cabs and anywhere a durable fi re rated Class or translucent partition or accent panel is required. Install with mechanical fasteners or frames. MTERILS Surface Finish: Durable matte fi nish with fi ngerprint, stain and scratch resistant fi nish, easily repairable and 100% renewable. Opaque Panels: and polycarbonate and acrylic materials colored on second surface (back) with durable color coating or color coating plus fi re retardant. Fully assembled s consist of acrylic layer with color coatings applied to second surface (back). crylic layer laminated to 1/2 (12mm) fi re rated MDF, with sheet adhesive transfer tape and fi re retardant back coating. Translucent Panels: Partition panels (, PETG or crylic) in 1/2 (12mm) thickness with color coating applied to second surface (back) and protected with clear coating. COLORS vailable in standard Palette colors, including a range of neutrals, pastels, muted, and brights or custom color match to Pantone, Designer colors, Paint Chip, RL, Fabric, or any other custom color sample. Classic colors include standard mirror color fi nishes. 2

3 OPTIONS Custom colors and patterns Digital printing Color matched caulk for reveal joints Pre-drilled mounting holes Fastening hardware, decorative screws, trim, stand-offs and cable systems For specifi cations regarding cleaning & maintenance, chemical resistance and other general information please see LIGHTLOCKS General Technical Specifi cations. FIRE RTING DT rchitectural Resins used for building interior fi nishes for walls and ceilings fall under the IC Code Chapter 8, Section 803 or the NFP 101 Life Safety Code Chapter 10, Section The test proscribed for materials used in these applications is the STM E84 test or in some instances the results from the NFP 286 test may be substituted where allowed. The only test that bestows and actual rating (Class, or C) is the STM E84 test. The determination of what Class rating is required for various locations and uses throughout a building interior is based on the chart provided in the IC Code Chapter 8, Table This chart cross-references building type with room type for both sprinklered and non-sprinklered buildings. While both the IC Code and the NFP 101 Code are generally accepted code guidelines across the United States and in many other countries all code enforcement is managed by local fi re inspection engineers and building inspection offi cials. When selecting building interior fi nishes one should always confi rm the applicable local codes for annotation or modifi cations to the IC or NFP Codes. s the STM E84 test is a material only test the material tested must be in its fi nished production state. Each iteration of the text material based on material properties, thickness and assembly components must be tested individually for the rating to apply. Variations of a material for size and component assembly do not confi rm one rating for the material onto a different iteration of the same base material. The NFP 286 test is a material and assembly test that requires the method of installation to be included in the test parameters and the product is to only be installed per this criteria. ll LIGHTLOCKS [FR] products are tested against the STM E84 test and are rated products tested in their fi nished production confi guration. Independent lab test reports are available for review. 3

4 PRODUCT Name SPECIFICTION IC 2009 Section Wall & Ceiling Finishes TEST & DTE STM E84 RTING / TEST REPORT For Product Description (See Test Results) Palette #POLY-16FR Canvas #POLY-16CFR Palette #POLY-8FR Canvas #POLY-8CFR Palette #POLY-4FR Canvas #POLY-4CFR Palette #CR-58FR Canvas #CR-58CFR Palette #CR-34FR Canvas #CR-34CFR Palette #CR-1FR Canvas #CR-1CFR Classic #CR-58MFR Designer #POLY-2TFR Designer #PETG-2TFR Designer #CR-2TFR Finished Product 1/16 (1.5mm) Finished Product 1/8 (3mm) Finished Product 1/4 (6mm) Finished Product 1/8 (3mm) crylic + 1/2 (12mm) MDF Finished Product 1/4 (6mm) crylic + 1/2 (12mm) MDF crylic + 1/2 (12mm) MDF Finished Product 1/8 (3mm) crylic Mirror + 1/2 (12mm) MDF PETG crylic July 25, 2012 Jan 11, 2013 May 9, 2012 Dec 9, 2011 Sept 19, 2011 June 4, 2012 June 27, 2012 May 12, 2011 May 12, 2011 July 1, 2012 Class Test Rpt # TJ Class Test Rpt # TJ Class Test Rpt # TJ Class Test Rpt # TJ0277 Class Test Rpt # TJ0112 Class Test Rpt # TJ Class Test Rpt # TJ Class Test Rpt # Class Test Rpt # Class Test Rpt # TJ

5 SPECIFICTION PHYSICL PROPERTIES Specific Gravity Refractive Index Light Transmission Water bsorption, 24 hrs. TEST STM D-792 STM D-542 STM D-1003 STM D570 LIGHTLOCKS crylic (FF) (6mm Thickness) %.02% MECHNICL Tensile Strength Modules of Elasticity Flexural Strength Modulus of Elasticity Compressive Strength Izod Impact Notched 73 F Rockwell Hardness arcol Hardness STM D-638 STM D-638 STM D-790 STM D-790 STM D895 STM D256 STM D785 STM D ,000 psi 400,000 psi 17,000 psi 480,000 psi 17,000 psi.4 ft-lb/in M THERML PROPERTIES Heat Deflection 264 psi Coefficient of Linear Thermal Expansion Flammability urn Rate Self Ignition Temperature Smoke Density Rating STM D648 STM D696 STM D635 STM D1929 STM D ºC (195 F) in/in - ºF m/m - ºC 25 mm/min 455ºC (850ºF) 4.87% The statements, technical information and recommendations contained herein are believed to be accurate as of the date indicated. Since the conditions and methods of use of the product and of the information referred to herein are beyond our control, LIGHTLOCKS expressly disclaims any and all liability as to any results obtained or arising from any use of the product or reliance on this information. No warranty of fi tness for any particular purpose, warranty for merchantability, or any other warranty expressed or implied is made concerning the goods described or the information provided herein. The information provided herein relates only to the specifi c product designated and may not be applicable when such product is used in combination with other materials or in any process. Some values will change with thickness. Specifi cations are subject to change without notice. 5

6 SPECIFICTION PHYSICL PROPERTIES Specific Gravity Refractive Index Light Transmission Water bsorption, 24 hrs. TEST STM D-792 STM D-542 STM D-1003 STM D570 LIGHTLOCKS (FF) (0.060 mm Thickness) %.15% MECHNICL Tensile Strength Modules of Elasticity Flexural Strength Modulus of Elasticity Izod Impact Strength, Izod Impact Strength, Instrumented Impact, STM D-638 STM D-790 STM D256 ft-lbs./in STM D256 ft-lbs./in STM D3763 ft-lbs 9,000 psi 345,000 psi 13,500 psi 345,000 psi ( no failure) >46 THERML PROPERTIES Heat Deflection 264 psi Coefficient of Thermal Expansion Coefficient of Thermal Conductivity Temperature (max. continuous service temperature) STM D-648 STM D F 3.75x 10-5 in./in. F 1.35 TU-in/hr-ft²- F 250 F FLMMILITY Smoke Density Horizontal burn (0.125 ) Self-Ignition Temperature Flammability Classifi cation Model uilding Codes Light Transmitting Plastics STM D-2843 STM D-635 STM D-1929 UL 94 UC & IC 65% <1 in F V2 < V CC-1 6