CUKLT. 57 kg (125 lb) 37" - 80" ( cm) #: ( ) ENG MAX KG/LB

Size: px
Start display at page:

Download "CUKLT. 57 kg (125 lb) 37" - 80" ( cm) #: ( ) ENG MAX KG/LB"

Transcription

1 CUKLT 37" - 80" ( cm) MAX KG/LB 57 kg (125 lb) ENG #: ( )

2 WARNING ENG - This product was designed to be installed on wood stud, solid concrete or block walls. Before installing make sure the supporting surface will support the combined load of the equipment and hardware. Screws must be tightly secured. Do not overtighten screws or damage can occur and product may fail. Never exceed the Maximum Load Capacity. Always use an assistant or mechanical lifting equipment to safely lift and position equipment. This product is intended for indoor use only. Use of this product outdoors could lead to product failure or personal injury. For support please call customer care at and select option 3. ENG Symbols # ENG WARNING ENG Skip to step. x3 ENG Screws must get at least three full turns and fi t snug. ENG Do not overtighten screws #: ( )

3 ENG Parts (Before beginning, make sure you have all parts shown below). A (1) wall plate B (1) adaptor plate C (1) adaptor plate F (1) G (1) extension plate extension plate D (2) concrete anchor E (2) No. 14 x 63.5mm (#14 x 2-1/2") wood screw I (4) M6 x 12 mm J (4) M6 x 20 mm H (4) M8 x 12mm K (4) M8 x 16 mm L (4) M8 x 25 mm M (2) fl at head screw N (2) nut O (4) M4/M5/M6 washer P (1) spirit level #: ( )

4 ENG Tools Needed for Assembly. ENG To properly tighten screws: Tighten until screw head makes contact, then tighten another 1/2 turn. Do not overtighten screws. 1 PENCIL 8mm (5/16") HAMMER 2 DRILL DRILL BIT 3 +1/2 4mm (5/32") 4 DRILL BIT SOCKET WRENCH 10mm (3/8") 5mm (3/16") SOCKET SOCKET PHILLIPS SCREW DRIVER EDGE TO EDGE STUD FINDER (FOR WOOD STUD WALLS) #: ( )

5 1 ENG Installation to Wood Stud wall. ENG Installation to Solid Concrete/Block wall. 1a 1b 1a WARNING ENG - When installing Peerless-AV wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the woods studs are a minimum of 51 x 102 mm (2" x 4") nominal size. When installing to more than one stud, ensure the spacing between studs is at least 406 mm (16") but does not exceed 610 mm (24"). Do not install over gypsum board thicker than 16 mm (5/8") #: ( )

6 1a-1 ENG Use stud finder to locate and mark stud centre lines. 1a-2 ENG Level wall plate. Mark mounting holes on stud centre lines. A #: ( )

7 1a-3 64mm (2.5") 4mm (5/32") 4mm (5/32") ENG Drill mounting holes into supporting surface (64mm (2.5") minimum depth required). ENG Mounting hole must centre on stud. 1a-4 10mm (3/8") ENG Level wall plate. Install using wood screws provided. A E (2) #: ( )

8 1b 1b-1 WARNING ENG When installing Peerless-AV wall mounts on a concrete wall, the wall must be at least 203 mm (8") thick with a minimum compressive strength of 2000 psi. When installing Peerless-AV wall mounts on hollow block verify that you have a minimum of 35 mm (1-3/8") of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 25 mm (1") minimum from the side of the block. Block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity. When installing Peerless-AV wall mounts on solid aggregate concrete masonry unit wall, minimum unit size must be 440mm x 215mm x 190mm. Minimum specifi cation for block is Solid Dense Group 1 Block, 7.3N compressive strength in compliance with BS EN Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 25mm (1") minimum from the side of the block. Never attach concrete expansion anchors to concrete or block covered with plaster, drywall, or other fi nishing material. ENG Level wall plate. Mark mounting holes. A 1b-2 64mm (2.5") 8mm (5/16") 8mm (5/16") ENG Drill mounting holes into supporting surface (64mm (2.5") minimum depth required). ENG Do not drill into mortar joints #: ( )

9 1b-3 D D (2) ENG Insert anchor fl ush to concrete. 1b-4 10mm (3/8") ENG Level wall plate. Install using concrete anchors and wood screws provided. A E (2) 2 VESA 600 X 400, 400 X 400: VESA 400 X 300, 300 X 300, 300 X 200, 200 X 200: 2a 2b #: ( )

10 2a ENG Use extension plates (F and G) for mounting hole patterns larger than 400 x 300mm. 5mm (3/16") F G M M N N B C #: ( )

11 2b ENG Centre adaptor brackets vertically on back of screen. VESA 400 X 300, 300 X 300, 300 X 200, 200 X 200: X VESA 600 X 400, 400 X 400: X C B F G B C X X 3 ENG Select the correct bolt (H,I,J,K,L) for the diameter and depth of the threaded holes on the screen back. x3 ENG Screws must get at least three full turns and fit snug. H C B O I K O J L #: ( )

12 4 ENG Lock/unlock latch 5 6 ENG Optional height adjustment ENG Tilt adjustment 10 ENG Turn adjustment screw clockwise / anitclockwise to raise or lower the screen on one or both mounting adaptors #: ( )

13 7 10mm (3/8") ENG OPTIONAL ENG To increase tension and maintain degree of tilt, tighten screw (x) on each adaptor bracket. If more tension is needed, tighten screws (y) on each adaptor bracket. y y x ENG Do not remove screw or loosen screw until it is no longer engaged with the mount. Doing so may cause the display to fall #: ( )

14 8 ENG Removing display. ENG Lock/unlock latch #: ( )

15 LIMITED FIVE-YEAR WARRANTY Peerless Industries, Inc. ( Peerless ) warrants to original end-users of Peerless products that they will be free from defects in material and workmanship, for a period of five years from the date of purchase by the original end-user (but in any case no longer than six years after the date of the product's manufacture). At its option, Peerless will repair or replace, or refund the purchase price of any product which fails to conform under normal usage with this warranty. In no event shall the duration of any implied warranty of merchantability or fitness for a particular purpose be longer than the period of the applicable express warranty set forth above. This warranty does not cover damage caused by (a) service or repairs by the customer or a person who is not authorised for such service or repairs by Peerless, (b) the failure to utilise proper packing when returning the product, (c) incorrect installation or the failure to follow Peerless' instructions or warnings when installing, using or storing the product, (d) misuse or accident when installed, or in transit or otherwise, including in cases of third party actions and force majeure. In no event shall Peerless be liable for incidental or consequential damages or losses arising from the incorrect installation of this product. This warranty is in lieu of all other warranties, expressed or implied, and is the sole remedy with respect to product defects. No dealer, distributor, installer or other person is authorised to modify or extend this Limited Warranty or impose any obligation on Peerless in connection with the sale of any Peerless product. This warranty does not affect your statutory rights #: ( )

16 Peerless-AV 2300 White Oak Circle Aurora, IL Ph: (800) Fax: (800) , Peerless Industries, Inc. Peerless-AV Europe Unit 3 Watford Interchange, Colonial Way, Watford, Herts, WD24 4WP, United Kingdom Customer Care 44 (0) , Peerless Industries, Inc. Peerless-AV de Mexico Ave de las Industrias 413 Parque Industrial Escobedo Escobedo N.L Mexico Servicio al Cliente , Peerless Industries, Inc.