Full Stone At Bottom of Wall with Wood Backup Wall Drainage and Weep Detail

Size: px
Start display at page:

Download "Full Stone At Bottom of Wall with Wood Backup Wall Drainage and Weep Detail"

Transcription

1 Full Stone At Bottom Wall with Wood Backup Wall Drainage and Weep Detail 10MM Sure Cavity TM (SCMM 2516 or SCMM 2532) and Stone Cavity Weep TM (SCV 5012) Sure Cavity TM Fabric to Face the Weather 10MM (SCMM 2516 or SCMM 5032) Sheathing Full Stone Veneer With Cavity Slushed Full Wall Ties As Required Wood Framing Weeps Scored and Cracked Off While Mortar is Still Plastic Trim Skirt to Overlap Stone Cavity Weep Stone Cavity Weep (SCV 5012) 06FR02WD001 details are created from sources deemed to be reliable. However, does not guarantee the accuracy or completeness any information, nor shall be held responsible for any errors, omissions, or damages arising out the use this information. These details are created with the understanding that is providing information but is not attempting to render engineering or other pressional service. If such services are required, the assistance an appropriate pression should be sought. Use materials in strict conformance with local building codes and regulations. Consult local code/code ficials prior to installation. It is the buyer's responsibility to ensure that materials are used in strict conformance with local building codes and regulations.

2 Full Stone Veneer Run-to-Grade and Cavity Slushed Full 10mm fabric Studs exterior building Sheathing Full Stone Veneer with Cavity Slugged Full Stone Wall Ties Sheathing Peel-and-Stick cut to follow stone line and cover mortar scored and cracked f while mortar is still plastic. and weep system to run down onto foundation wall a minimum 2 Cavity Slushed Full Waterproing 06FR10WD001 details are created from sources deemed to be reliable. However, does not guarantee the accuracy or completeness any information, nor shall be held responsible for any errors, omissions, or damages arising out the use this information. These details are created with the understanding that is providing information but is not attempting to render engineering or other pressional service. If such services are required, the assistance an appropriate pression should be sought. Use materials in strict conformance with local building codes and regulations. Consult local code/code ficials prior to installation. It is the buyer's responsibility to ensure that materials are used in strict conformance with local building codes and regulations.

3 Full Stone Veneer at Bottom and Side Window and Framed Backup Wall Backer Rod Tape Caulk Full Stone Veneer 10mm Sure Cavity to abut the window frame Stone Achors 05FR03WD001 details are created from sources deemed to be reliable. However, does not guarantee the accuracy or completeness any information, nor shall be held responsible for any errors, omissions, or damages arising out the use this information. These details are created with the understanding that is providing information but is not attempting to render engineering or other pressional service. If such services are required, the assistance an appropriate pression should be sought. Use materials in strict conformance with local building codes and regulations. Consult local code/code ficials prior to installation. It is the buyer's responsibility to ensure that materials are used in strict conformance with local building codes and regulations.

4 Full Stone Veneer at Top Window Steel Lintel Installation on Wood Framed Wall fabric fabric to lap over Moisture DiverterTM Sheathing and and Moisture Diverter (DS 2858) Peel and Stick Moisture Diverter (DS 2858) Steel Lintel Sheathing Drip Plate Scored and Cracked Off While Mortar is Still Plastic. 10mm 06FR03WD002 details are created from sources deemed to be reliable. However, does not guarantee the accuracy or completeness any information, nor shall be held responsible for any errors, omissions, or damages arising out the use this information. These details are created with the understanding that is providing information but is not attempting to render engineering or other pressional service. If such services are required, the assistance an appropriate pression should be sought. Use materials in strict conformance with local building codes and regulations. Consult local code/code ficials prior to installation. It is the buyer's responsibility to ensure that materials are used in strict conformance with local building codes and regulations.

5 Full Stone Veneer Top-Vented Wall Stopped at Sfit and Floor Edging (FE 8555) Sfit Trim Board Back-wrap fabric for bug screen Mortar Joint tuckpointed to Floor Edging (Tool mortar joint and cut Floor Edging TM at wall line while mortar is still plastic) Sure Cavity TM fabric Floor Edging (FE 8555) 10mm Sheathing Wall Ties Stone Veneer 06FR05WD001 Copyright Masonry Technology Incorporated, 2009 All Rights Reserved. details are created from sources deemed to be reliable. However, does not guarantee the accuracy or completeness any information, nor shall be held responsible for any errors, omissions, or damages arising out the use this information. These details are created with the understanding that is providing information but is not attempting to render engineering or other pressional service. If such services are required, the assistance an appropriate pression should be sought. Use materials in strict conformance with local building codes and regulations. Consult local code/code ficials prior to installation. It is the buyer's responsibility to ensure that materials are used in strict conformance with local building codes and regulations.