NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)

Size: px
Start display at page:

Download "NEMO etc. Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203)"

Transcription

1 Certificate of Authorization # Christian Street, Unit #13 Oxford, CT (203) ENGINEER EVALUATE TEST CONSULT CERTIFY Firestone Building Products Company, LLC th Avenue South Nashville, TN (800) EVALUATION REPORT Evaluation Report F R4 FL16723-R4 Date of Issuance: 12/12/2013 Revision 4: 03/20/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6 th Edition (2017) Florida Building Code, High Velocity Hurricane Zone (HVHZ) sections noted herein. DESCRIPTION: Firestone Single Ply Roof s LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words Evaluated may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 48-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 03/20/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose.

2 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof s Compliance Statement: Firestone and XR Single Ply Roof s, as produced by Firestone Building Products, have demonstrated compliance with the following sections of the 6 th Edition (2017) Florida Building Code, HVHZ through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year TAS 110 Wind, Impact TAS TAS 110 Physical Properties TAS REFERENCES: Entity Exam Reference Date Entity Exam Reference Date ACRC (TST4671) TAS 114 ACRC /18/2005 FM (TST1867) FM /05/2012 ACRC (TST4671) TAS 114 ACRC /07/2003 FM (TST1867) FM /10/2012 ACRC (TST4671) TAS 114 ACRC /21/2006 FM (TST1867) FM /14/2012 ERD (TST 6049) FM 4474 F /04/2009 FM (TST1867) FM /14/2012 ERD (TST 6049) FM 4474 F /16/2010 FM (TST1867) FM /14/2012 ERD (TST 6049) FM 4474 F /13/2014 FM (TST1867) FM /30/2012 ERD (TST 6049) ASTM D6878 F /12/2014 FM (TST1867) FM /24/2013 ERD (TST 6049) ASTM D6878 F R1 03/20/2017 FM (TST1867) FM /29/2013 FM (TST1867) FM /24/1999 FM (TST1867) FM /29/2013 FM (TST1867) FM /26/1999 FM (TST1867) FM /22/2013 FM (TST1867) FM /03/1999 FM (TST1867) FM /26/2013 FM (TST1867) FM /08/2000 FM (TST1867) FM /30/2013 FM (TST1867) FM /22/2002 FM (TST1867) FM /15/2013 FM (TST1867) FM /17/2003 FM (TST1867) FM /15/2013 FM (TST1867) FM /30/2004 FM (TST1867) FM /16/2013 FM (TST1867) FM /29/2004 FM (TST1867) FM /09/2015 FM (TST1867) FM /30/2004 FM (TST1867) FM /20/2015 FM (TST1867) FM /30/2004 FM (TST1867) FM /18/2015 FM (TST1867) FM /03/2004 FM (TST1867) FM /05/2016 FM (TST1867) FM /28/2005 FM (TST1867) FM /17/2017 FM (TST1867) FM /14/2006 PRI (TSTTST5878) FM 4474 FBP /04/2012 FM (TST1867) FM /15/2006 PRI (TSTTST5878) FM 4474 FBP /04/2012 FM (TST1867) FM /14/2006 PRI (TST5878) FM 4474 FBP /25/2013 FM (TST1867) FM /07/2007 PRI (TST5878) FM 4474 FBP /22/2013 FM (TST1867) FM /22/2007 PRI (TST5878) FM 4474 FBP /23/2013 FM (TST1867) FM /18/2007 PRI (TST5878) FM 4474 FBP /18/2013 FM (TST1867) FM /02/2007 PRI (TST5878) FM 4474 FBP /18/2013 FM (TST1867) FM /16/2008 PRI (TST5878) FM 4474 FBP /18/2013 FM (TST1867) FM /12/2008 PRI (TST5878) FM 4474 FBP /18/2013 FM (TST1867) FM /15/2009 PRI (TST5878) FM 4474 FBP /18/2013 FM (TST1867) FM /22/2009 PRI (TST5878) ASTM D6878 FBP /26/2014 FM (TST1867) FM /29/2009 PRI (TST5878) FM 4474 FBP /28/2014 FM (TST1867) FM /09/2009 PRI (TST5878) FM 4474 FBP /28/2014 FM (TST1867) FM /09/2009 PRI (TST5878) FM 4474 FBP A 04/28/2014 FM (TST1867) FM /11/2010 PRI (TST5878) FM 4474 FBP /28/2014 FM (TST1867) FM /07/2010 PRI (TST5878) FM 4474 FBP /28/2014 FM (TST1867) FM /30/2010 PRI (TST5878) FM 4474 FBP /28/2014 FM (TST1867) FM /02/2010 PRI (TST5878) FM 4474 FBP /01/2014 FM (TST1867) FM /14/2010 PRI (TST5878) FM 4474 FBP A 07/15/2014 FM (TST1867) FM /16/2010 PRI (TST5878) FM 4474 FBP /27/2014 FM (TST1867) FM /30/2010 PRI (TST5878) FM 4474 FBP /31/2014 FM (TST1867) FM /30/2010 PRI (TST5878) FM 4474 FBP /31/2014 FM (TST1867) FM /05/2010 PRI (TST5878) FM 4474 FBP /31/2014 FM (TST1867) FM /18/2010 PRI (TST5878) FM 4474 FBP /31/2014 FM (TST1867) FM /17/2010 PRI (TST5878) FM 4474 FBP /31/2014 FM (TST1867) FM /04/2011 PRI (TST5878) UL1897 FBP /16/2014 FM (TST1867) FM /14/2011 PRI (TST5878) UL1897 FBP /16/2014 FM (TST1867) FM /01/2011 PRI (TST5878) FM 4474 FBP /21/2014 FM (TST1867) FM /02/2011 PRI (TST5878) UL1897 FBP /21/2014 FM (TST1867) FM /07/2011 PRI (TST5878) UL 1897 FBP /22/2014 Evaluation Report F R4 Certificate of Authorization # TH EDITION (2017) FBC HVHZ EVALUATION FL16723-R4 Firestone Single Ply Roof s Revision 4: 03/20/2018 Page 2 of 4

3 Entity Exam Reference Date Entity Exam Reference Date FM (TST1867) FM /08/2011 PRI (TST5878) UL1897 FBP /20/2014 FM (TST1867) FM /10/2011 PRI (TST5878) FM 4474 FBP /20/2014 FM (TST1867) FM /03/2011 PRI (TST5878) FM 4474 FBP /20/2014 FM (TST1867) FM /04/2011 PRI (TST5878) UL1897 FBP /29/2015 FM (TST1867) FM /04/2011 PRI (TST5878) FM 4474 FBP /02/2015 FM (TST1867) FM /16/2011 PRI (TST5878) FM 4474 FBP /11/2015 FM (TST1867) FM /13/2011 UL (TST1740) UL CA /20/2010 FM (TST1867) FM /22/2011 UL (TST1740) UL NK /13/2011 FM (TST1867) FM /05/2012 UL, LLC (QUA9625) QC Service Confirm Exp. 09/11/ PRODUCT DESCRIPTION: The following roof covers are mechanically attached or fully adhered to Approved substrates using fasteners, stress plates and adhesives, as outlined in the Limitations / Conditions of Use herein. 4.1 Firestone is a nominal 45-mil (1.1 mm), 60-mil (1.5 mm) or 80-mil (2.0 mm) thick, polyester scrim reinforced single-ply roof membrane. 4.2 Firestone XR is a nominal 45-mil (1.1 mm) (XR 100), 60-mil (1.5 mm) (XR 115) or 80-mil (2.0 mm) (XR 135) thick, polyester reinforced, single-ply roof membrane produced with an 8-oz polyester backing 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 Fire classification is not part of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.3 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC unless the exceptions stated in FBC and apply. 5.4 The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to as-tested conditions under Testing Application Standard TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements to the satisfaction of the Authority Having Jurisdiction. 5.5 Fastener spacing for mechanical attachment of anchor/base sheet or membrane is based on a minimum fastener resistance value in conjunction with the maximum design pressure () listed for a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing prepared, signed and sealed by a qualified design professional may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations in compliance with Roofing Application Standard RAS 117 or Roofing Application Standard RAS If mechanical attachment to the structural deck through lightweight insulating is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or Roofing Application Standard RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional. 5.6 For systems where specific lightweight insulating is referenced, consult the current HVHZ product approval documentation for specific deck construction and limitations. For systems where specific lightweight insulating is not referenced, the minimum design mix shall be for minimum 300 psi cellular material. 5.7 For recover installations, the existing roof shall be examined in accordance with FBC Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased, as calculated in compliance with Roofing Application Standard RAS 117 and/or Roofing Application Standard RAS 137 by a qualified design professional. *This extrapolation is not permitted for systems marked with an asterisk*. 5.9 All attachment and sizing of perimeter nailers, metal profile and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. Evaluation Report F R4 Certificate of Authorization # TH EDITION (2017) FBC HVHZ EVALUATION FL16723-R4 Firestone Single Ply Roof s Revision 4: 03/20/2018 Page 3 of 4

4 5.10 For assemblies marked with an asterisk*, the maximum design pressure () limitation listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners) For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with Testing Application Standard TAS All products listed herein shall have quality assurance audit in accordance with the F.A.C. Rule 61G INSTALLATION: 6.1 Firestone and XR shall be installed in accordance with Firestone Building Products published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 attachment requirements for wind load resistance are set forth in Appendix 1. = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per Testing Application Standard TAS 114 has already been applied). Refer to FBC 1620 and Roofing Application Standard RAS 128 for determination of design wind loads. 6.3 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. 6.4 For InvisiWeld installations, care shall be taken to ensure that the InvisiWeld Plates do not line-up with seams in the TPO membrane. This condition precludes proper induction welding of the membrane to the InvisiWeld Plates. 7. QUALITY ASSURANCE ENTITY: UL, LLC QUA9625; (414) ; Karen.buchmann@us.ul.com - THE 48-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT Evaluation Report F R4 Certificate of Authorization # TH EDITION (2017) FBC HVHZ EVALUATION FL16723-R4 Firestone Single Ply Roof s Revision 4: 03/20/2018 Page 4 of 4

5 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT NCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 4 1B Wood New, Reroof (Tear-Off), Recover C-2 Plate-Bonded Roof Cover 4 1C Wood New, Reroof (Tear-Off), Recover D-1 Insulated, Mechanically Attached Roof Cover 5 1D Wood New, Reroof (Tear-Off), Recover E Non-Insulated, Mechanically Attached Roof Cover 5 2A Steel or New, Reroof (Tear-Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 6-9 2B Steel or New, Reroof (Tear-Off), Recover B-2 Mech. Attached Base Insulation, Bonded Temp Roof, Bonded Top Insulation, Bonded Roof Cover 10 2C Steel or New, Reroof (Tear-Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover D Steel or New, Reroof (Tear-Off), Recover C-2 Plate-Bonded Roof Cover E Steel or New, Reroof (Tear-Off), Recover D-1 Insulated, Mechanically Attached Roof Cover (Stress Plates) F Steel or New, Reroof (Tear-Off), Recover D-1 Insulated, Mechanically Attached Roof Cover (Battens) A New, Reroof (Tear-Off) A-1A Bonded Insulation, Bonded Roof Cover B New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 28 4A Lightweight New, Reroof (Tear-Off) A-1A Bonded Insulation, Bonded Roof Cover B Lightweight New, Reroof (Tear-Off) or Recover D-1 Insulated, Mechanically Attached Roof Cover 38 4C Lightweight New, Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover A Cementitious wood fiber New, Reroof (Tear-Off) A-1A Bonded Insulation, Bonded Roof Cover 40 5B Cementitious wood fiber New, Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 40 6A Existing gypsum Reroof (Tear-Off) A-1A Bonded Insulation, Bonded Roof Cover 41 6B Existing gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 41 7A Various Recover A-1A Bonded Insulation, Bonded Roof Cover B Steel Recover C-2 Plate-Bonded Roof Cover 47 7C Steel Recover D-1 Insulated, Mechanically Attached Roof Cover 47 7D Steel Recover D-2 Insulated, Mechanically Attached Roof Cover (RMA Strips) 48 7E Steel Recover E Non-Insulated, Mechanically Attached Roof Cover 48 7F Various Recover F Non-Insulated, Bonded Roof Cover 48 The following notes apply to the systems outlined herein: 1. The evaluation herein pertains to above-deck roof components; deck-attachment details pertain to as-tested conditions under Testing Application Standard TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: Wood : Firestone All-Purpose or Heavy-Duty Fasteners with Firestone Insulation Fastening Plates. Minimum 1-inch plywood penetration or wood plank embedment. Steel : Firestone All-Purpose, All-Purpose S or Heavy-Duty Fasteners with Firestone Insulation Fastening Plates. Minimum ¾-inch steel penetration, engage the top flute of the steel deck. : Firestone Heavy-Duty or Concrete Drive Fasteners with Firestone Insulation Fastening Plates. Minimum 1.25-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer s published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite or gypsum-based roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. If mechanical attachment to the structural deck through lightweight insulating is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared, signed and sealed by a qualified design professional. Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 1 of 48

6 5. Preliminary insulation attachment for Type C-2 and D = Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer s published instructions: Firestone I.S.O. FIX II: Continuous ¾ to 1-inch wide ribbons, 12- Firestone I.S.O. Spray R: Continuous ½ to ¾ -inch wide ribbons, 12- Firestone : Continuous ¾ to 1-inch wide ribbons, 12- Firestone I.S.O. : Continuous ½ to ¾-inch beads, 12- ICP CR-20: Continuous 2½ to 3½-inch ribbons, 12- Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. In no case shall these values be used to increase the listings in the tables; rather if listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. Tapered ISO 95+ at the following thickness limitations may be substituted with the following Maximum Design Pressure () limitations. Firestone I.S.O. FIX II: psf (Min. 0.5-inch thick) Firestone I.S.O. Spray R: psf (Min. 0.5-inch thick) Firestone : psf (Min. 0.5-inch thick) Firestone I.S.O. : psf (Min. 0.5-inch thick) ICP CR-20: psf (Min. 1.0-inch thick Tapered ISO 95+ only) Tapered at the following thickness limitations may be substituted with the following Maximum Design Pressure () limitations. Firestone I.S.O. FIX II, 12-: psf (Min. 0.5-inch thick) Firestone I.S.O. FIX II, 6-: psf (Min. 0.5-inch thick) Firestone I.S.O. Spray R, 12-: psf (Min. 0.5-inch thick) Firestone I.S.O. Spray R, 6-: psf (Min. 0.5-inch thick) Firestone, 12-: psf (Min. 0.5-inch thick) Firestone, 6-: psf (Min. 0.5-inch thick) Firestone I.S.O., 12-: psf (Min. 0.5-inch thick) Firestone I.S.O., 6-: psf (Min. 0.5-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased, as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137 by a qualified design professional. *This extrapolation is not permitted for systems marked with an asterisk*. 10. For assemblies marked with an asterisk*, the maximum design pressure () limitation listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners). 11. Fastener spacing for mechanical attachment is based on a minimum fastener resistance value in conjunction with the maximum design pressure () listed for a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing prepared, signed and sealed by a qualified design professional may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations in compliance with Roofing Application Standard RAS 117 or RAS For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with Testing Application Standard TAS For Type D, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For recover installations, the existing roof shall be examined in accordance with FBC For Recover Applications using Type C-2 or D, the insulation is optional. Alternatively, ISOGARD HD, ISO 95+,, other polyisocyanurate, Dens, Dens Prime, SECUROCK, SECUROCK Glass-Mat Roof Board, GreenGuard Roofing Insulation Boards, Insulfoam EPS with necessary slip sheet Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 2 of 48

7 or wood fiberboard may be used as a separator board, preliminarily attached prior to roof cover installation. The separator component shall be documented as meeting FBC (HVHZ) 1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 15. For systems where specific lightweight insulating (LWIC) is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. 16. For adhered membrane systems, side laps shall be minimum 3-inch wide sealed with min. 1.5-inch heat weld. Membrane adhesive application rates are as follows: Membrane Adhesive Method Rate UltraPly Bonding Adhesive (UP-) Contact Application 45 to 60 ft 2 /gal Water Based Bonding Adhesive-S (WB-S) Contact Application 100 to 120 ft 2 /gal. Water Based Bonding Adhesive-P (WB-P) Contact Application 100 to 120 ft 2 /gal. Single-Ply LVOC Bonding Adhesive (LVOC-) Contact Application 45 to 60 ft 2 /gal Single-Ply LVOC Bonding Adhesive 1168 (LVOC--1168) Contact Application 45 to 60 ft 2 /gal XR XR Bonding Adhesive (XR-) Substrate Application 70 to 90 ft 2 /gal XR Water Based Bonding Adhesive-P (WB-P) Substrate Application 100 to 120 ft 2 /gal. XR XR Stick Membrane Adhesive Substrate Application Continuous ¾ to 1-inch wide ribbons, spaced as noted XR I.S.O. Spray R Substrate Application Continuous ¾ to 1-inch wide ribbons, spaced as noted 17. Vapor barrier options for use over structural deck followed by adhesive-applied insulation carry the following Maximum Design Pressure () limitations. Use the lesser of the listings below vs. those in Table 3A. VAPOR RRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: Option Vapor Barrier Primer Insulation Adhesive (Note 6) # Type Application VB-1. ASTM D41 Base Ply: MB Base, SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Multi-Purpose MB Cold Poly Base, APP 160 COOL, APP 170 COOL Adhesive, gal/sq. Multi-Purpose MB Cold Adhesive -67.5* VB-2. MB Base LiquiGard, gal/sq. I.S.O. Spray R, 12 o.c * VB-3. MB Base LiquiGard, gal/sq. I.S.O., 12 o.c * VB-4. SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Poly Base LiquiGard, gal/sq. I.S.O. Spray R, 12 o.c * VB-5. SBS Base, SBS Base-P, SBS PolyBase, SBS Premium Base, SBS Premium Poly Base LiquiGard, gal/sq. I.S.O., 12 o.c * VB-6. ASTM D41 MB Base I.S.O., 4 o.c. I.S.O., * VB-7. ASTM D41 1 or 2 plies Ply IV or Ply VI or 1 ply MB Base, SBS Base, SBS Polybase or SBS Premium Base Hot asphalt Hot asphalt * VB-8. ASTM D41 1 or 2 plies Ply IV or Ply VI or 1 ply MB Base, SBS Base, SBS Polybase or SBS Premium Base Hot asphalt I.S.O. Spray R or I.S.O., 12 o.c * VB-9. ASTM D41 SBS-TA; SBS Poly Torch Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Smooth Torch-applied I.S.O. Spray R or I.S.O., 12 o.c * VB-10. V-Force SB Primer V-Force Vapor Barrier Self-adhering I.S.O. Spray R, 12 o.c * VB-11. V-Force SB Primer V-Force Vapor Barrier Self-adhering, 12 o.c * VB-12. V-Force SB Primer V-Force Vapor Barrier Self-adhering I.S.O., 12 o.c * 18. For membrane attachment using batten-strips, batten-strip end laps shall be spliced with sufficient dimension to allow for minimum 2-fasteners at each batten-strip lap. 19. For InvisiWeld installations, care shall be taken to ensure that the InvisiWeld Plates do not line-up with seams in the TPO membrane. This condition precludes proper induction welding of the membrane to the InvisiWeld Plates. 20. An optional air/vapor barrier of V-Force Vapor Barrier Membrane, self-adhered, may be installed atop steel roof decks (Tables 2A through 2C) prior to installation of any steel deck roof assembly noted herein. 21. = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC (HVHZ) 1620 and RAS 128 for determination of design wind pressures. Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 3 of 48

8 ULTRAPLY TPO SYSTEMS W-1. W-2. W-3. W-4. W-5. Min. 19/32-inch plywood or wood plank; 24 span; 8d nails 6 o.c. Min. 19/32-inch plywood or wood plank; 24 span; x 2-3/8 ring shank nails 6 o.c. Min. 19/32-inch plywood or wood plank; 24 span; 8d nails 6 o.c. Min. 19/32-inch plywood or wood plank; 24 span; 8d nails 6 o.c. Min. 19/32-inch plywood or wood plank; 24 span; x 2-3/8 ring shank nails 6 o.c. TABLE 1A: WOOD DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Top Insulation Layer Type Fasten Attach 2 / UP-, LVOC--1168, Min. 2-inch ISO 95+ Note 2 1 per 1.78 ft WB-S, WB-P 2 / UP-, LVOC--1168, Min. 1-inch Note 2 1 per 1.6 ft LVOC- Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board, Dens or Dens Prime Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board or Dens Prime Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 1.6 ft 2 / UP-, WB-S, WB-P Note 2 1 per 1.6 ft 2 / LVOC Note 2 1 per 1.78 ft 2 / UP-, LVOC--1168, LVOC TABLE 1B: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER W-6. W-7. W-8. Min. 19/32-inch plywood or wood plank; 24 span; 8d nails 6 o.c. Min. 19/32-inch plywood or wood plank; 24 span; 8d nails 6 o.c. Min. 19/32-inch plywood or wood plank; 24 span; #8 screws 6 o.c. Insulation Layer any combination, preliminarily attached any combination, preliminarily attached any combination, preliminarily attached Fasten Firestone Heavy Duty Fasteners and InvisiWeld Plates Firestone Heavy Duty Fasteners and InvisiWeld Plates Firestone Heavy Duty Fasteners and InvisiWeld Plates Attach Density / Pattern Max. 6- in rows max. 72- Roof Cover bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates 12 parts per 4 x 8 ft board 1 per 2.67 ft 2 with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. Max. 6- in rows max. 60- bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 4 of 48

9 W-9. W-10. Min. 19/32-inch plywood or wood plank; 24 span; 8d nails 6 o.c. Min. 19/32-inch plywood or wood plank; 24 span; 10d nails 4 o.c. at perimeter; 8d nails 6 o.c. in field TABLE 1C: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER Insulation Roof Cover Type Attach Membrane Fasten Attach Optional min. 1-inch ISO 95+ followed by min inch Dens, Dens Prime or SECUROCK Gypsum- Fiber Roof Board, min. 0.5-inch ISOGARD HD, min. 1-inch or min. 1.5-inch ISOGARD HD Composite Min. 1.5-inch thick, one or more layers, any combination Prelim. attached Prelim. attached (min. 60-mil) Firestone HD Fasteners with Firestone HD Seam Plates Firestone HD Fasteners with Firestone HD Seam Plates 5- within 6-inch wide laps spaced 114- Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced Laps sealed with 5-inch heat weld that encapsulates plates W-11. Min. 19/32-inch plywood or wood plank; 24 span; 8d nails 6 o.c. TABLE 1D: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED ROOF COVER Roof Cover Membrane Fasten Attach Firestone HD Fasteners with Firestone HD Seam Plates 6- within 6-inch wide laps spaced 72-inch o.c. Laps sealed with 1.5-inch heat weld Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 5 of 48

10 ULTRAPLY TPO SYSTEMS SC-1. SC-2. SC-3. SC-4. SC-5. SC-6. SC-7. SC-8. SC-9. SC-10. SC-11. SC-12. steel or strutural steel or strutural steel or strutural steel or strutural steel or strutural steel or strutural steel or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel or strutural steel or strutural steel or strutural steel or strutural TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY FASTENED SE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Top Insulation Layer Type Fastener Attach Type Attach Min. 1.5-inch Note 2 Note 2 1 per 2 ft 2 Optional min. 1.5-inch ISO 95+ followed by min. 0.5-inch Tapered ISO per 2.7 ft 2 Optional min. 1.5-inch followed by min. 0.5-inch Tapered Min. 2-inch Note 2 1 per 4 ft 2 Optional min. 1.5-inch followed by min. 0.5-inch Tapered Min. 2-inch ISO 95+ Note 2 1 per 4 ft 2 Min. 1.5-inch ISOGARD HD Composite Note 2 I.S.O. Spray R I.S.O. FIX II; ; I.S.O. FIX II; ; I.S.O. FIX II; ; I.S.O. FIX II; ; 1 per 2.7 ft 2 Min. 1.5-inch ISOGARD HD Composite Note 2 1 per 2 ft 2 Min. 0.5-inch ISOGARD HD Min. 2-inch ISO 95+ Note 2 1 per 2 ft 2 Min. 0.5-inch ISOGARD HD I.S.O. FIX II; Min. 2-inch ISO 95+ Note 2 1 per 1 ft 2 Min. 0.5-inch ISOGARD HD Min. 0.5-inch Dens Prime or SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 2 ft 2 Min inch Dens, Dens Prime or SECUROCK Note 2 1 per 2 ft 2 Min inch Dens Prime or SECUROCK Note 2 1 per 2 ft inch Tapered ISO 95+ followed by Optional min. 1.5-inch ISO 95+ or min. min. 0.5-inch ISOGARD HD 2 Optional min. 1.5-inch followed by Note 2 1 per 4 ft min. 0.5-inch Tapered I.S.O. FIX II; ;, or ICP CR-20, or ICP CR-20 I.S.O. Spray R I.S.O. FIX II; ; / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / WB-S, WB-P-S Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 6 of / UP- / LVOC / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC-

11 SC-13. SC-14. SC-15. SC-16. SC-17. SC-18. SC-19. SC-20. SC-21. SC-22. steel or strutural steel or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural Min. 22 ga., type B, 50 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. or strutural Min. 22 ga., type B, 50 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY FASTENED SE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Top Insulation Layer Type Fastener Attach Type Attach Min. 0.5-inch Dens, Dens Prime or SECUROCK Gypsum-Fiber Roof Board Min. 0.5-inch Dens, Dens Prime or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2 ft 2 followed by min. 0.5-inch FiberTop C or S Note 2 1 per 2 ft inch Dens Prime or SECUROCK followed by Min. Note 2 Note 2 Min. 2-inch ISO 95+ Note 2 Note 2 Min. 2-inch ISO 95+ Note 2 1 per 1.6 ft 2 Min. 0.5-inch Dens Prime or SECUROCK I.S.O. FIX II; ; I.S.O. FIX II; ; I.S.O. FIX II; ;, 6- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC-, WB-S, WB-P-S / UP-, LVOC--1168, LVOC- 1 per 1.78 ft 2 Min. 1.5-inch ISOGARD HD Composite, 12- / UP-, LVOC--1168, LVOC- 1 per 1.78 ft 2 Min inch SECUROCK Gypsum-Fiber Roof Board Min. 2-inch ISO 95+ Note 2 1 per 1 ft 2 Min. 0.5-inch ISOGARD HD Min. 2-inch ISO 95+ Note 2 1 per 1 ft 2 Min. 1-inch ISO 95+, 6-1 per 1.6 ft 2 I.S.O. FIX II; ; 1 per 1.6 ft 2 Min. 0.5-inch ISOGARD HD, 6-2 Min. 0.5-inch Dens Prime or SECUROCK Min. 2-inch ISO 95+ Note 2 1 per 1 ft I.S.O. FIX II; ;, 4- I.S.O. FIX II; ;, 4- I.S.O. FIX II; ;, 4- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / WB-S, WB-P / UP-, LVOC--1168, LVOC Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 7 of 48

12 SC-23. SC-24. SC-25. SC-26. SC-27. SC-28. steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural Min. 22 ga., type B, Grade 80 steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural Min. 22 ga., type B, Grade 80 steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural ULTRAPLY TPO XR SYSTEMS: SC-29. SC-30. SC-31. steel or strutural steel or strutural steel or strutural TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY FASTENED SE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Top Insulation Layer Type Fastener Attach Type Attach Min. 2-inch ISO 95+ Note 2 1 per 1 ft 2 Min. 2-inch ISO 95+ Note 2 1 per 1 ft inch ISOGARD HD or min. 19/32-inch followed by min. plywood Min. 2-inch ISO 95+ Note 2 1 per 1 ft 2 Min. 1-inch ISO 95+ Min. 1.5-inch Note 2 1 per 1 ft 2 Min. 1.5-inch Min. 2-inch ISO 95+ Note 2 1 per 1 ft 2 Min. 1-inch ISO 95+ Min. 2-inch ISO 95+ Note 2 1 per 1 ft 2 Min. 0.5-inch ISOGARD HD Min. 0.5-inch Dens, Dens Prime or SECUROCK Gypsum-Fiber Roof Board Min inch ISO 95+ Min. 0.5-inch Dens or SECUROCK Gypsum-Fiber Roof Board Note 2 1 per 2 ft inch FiberTop C or S or Min inch Dens Prime or SECUROCK Gypsum- followed by min. Fiber Roof Board Note 2 1 per 4 ft 2 Note 2 1 per 2 ft 2 followed by optional min. 0.5-inch FiberTop C or S wood fiber, Min. 0.5-inch Dens Prime or SECUROCK or min. 19/32-inch plywood I.S.O. Spray R, 6-inch o.c. I.S.O. Spray R, 6-inch o.c. I.S.O. FIX II; ;, 4- I.S.O. FIX II; ; I.S.O. FIX II; ;, 4- I.S.O. FIX II; ;, 4- I.S.O. FIX II; ; I.S.O. FIX II; ; I.S.O. Spray R / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC XR / XR- XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 12- Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 8 of 48

13 SC-32. SC-33. SC-34. SC-35. SC-36. SC-37. SC-38. SC-39. SC-40. steel or strutural steel or strutural steel or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; #12 HWH Teks 5, 6 o.c. Min. 22 ga., type B, Grade 80 steel; 6 spans; #12 HWH Teks 5, 6 o.c. or min. 2,500 psi structural steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY FASTENED SE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER Top Insulation Layer Type Fastener Attach Type Attach Min. 0.5-inch Dens or SECUROCK Gypsum-Fiber Roof Board 2 followed by min. Note 2 1 per 2 ft 0.5-inch ISOGARD HD Note 2 1 per 2 ft 2 inch FiberTop C or S wood fiber or Min inch Dens Prime or SECUROCK Min. 1-inch ISO 95+ followed by min Optional min. 1-inch ISO 95+ followed by Note 2 1 per 2 ft min. 0.5-inch ISOGARD HD Note 2 Min. 2-inch ISO 95+ Note 2 Min. 2-inch ISO 95+ Note 2 Min. 2-inch ISO 95+ Min. 2-inch ISO per 1.6 ft 2 Min. 0.5-inch Dens Prime or SECUROCK I.S.O. Spray R I.S.O. FIX II; ; I.S.O. FIX II; ; I.S.O. FIX II; ;, 6- I.S.O. FIX II; ; 1 per 1.6 ft 2 Min. 1-inch ISO 95+, 6- I.S.O. FIX II; ; 1 per 1.6 ft 2 Min. 0.5-inch ISOGARD HD, 6- Note 2 1 per 1 ft 2 Min. 0.5-inch Dens Prime I.S.O. Spray R Note 2 1 per 1 ft 2 Min. 0.5-inch Dens Prime I.S.O. Spray R 2 Min. 0.5-inch Dens Prime or SECUROCK Min. 2-inch ISO 95+ Note 2 1 per 1 ft I.S.O. FIX II; ;, 4- XR / I.S.O. Spray R or XR Stick, 4- XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 6- XR / I.S.O. Spray R or XR Stick, 6- XR / I.S.O. Spray R or XR Stick, 6- XR / I.S.O. Spray R, 12- XR / I.S.O. Spray R, 12- XR / I.S.O. Spray R or XR Stick, Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 9 of 48

14 ULTRAPLY TPO SYSTEMS SC-41. SC-42. SC-43. SC-44. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural ULTRAPLY TPO XR SYSTEMS SC-45. Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-2: MECHANICALLY FASTENED SE INSULATION, BONDED TEMP ROOF, BONDED TOP INSULATION, BONDED ROOF COVER Insulation Temp Roof Type Fasten Attach Type Attach Min inch FM Approved perlite Min inch Dens or min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board Min inch Dens or min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board Min inch Dens or min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board Min inch Dens or min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 2 ft 2 Type IV or Type VI in Two plies Firestone hot asphalt Note 2 1 per 4 ft 2 Force Vapor Barrier Membrane, selfadhered V-Force SB Primer; V- Note 2 1 per 4 ft 2 Force Vapor Barrier Membrane, selfadhered V-Force SB Primer; V- Note 2 1 per 4 ft 2 Force Vapor Barrier Membrane, selfadhered V-Force SB Primer; V- Note 2 1 per 4 ft 2 Force Vapor Barrier Membrane, selfadhered V-Force SB Primer; V- followed by Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board One or more layers min. 1.5-inch ISO 95+, optional min. 0.5-inch Tapered ISO 95+ One or more layers min. 1.5-inch ISO 95+, optional min. 0.5-inch Tapered ISO 95+ ; Min. 0.5-inch FiberTop C or S or ISOGARD HD or Min inch Dens Prime or SECUROCK Gypsum- Fiber Roof Board; or Min. 19/32-inch plywood One or more layers min. 1.5-inch ISO 95+, optional min. 0.5-inch Tapered ISO 95+ ; Min inch Dens or SECUROCK Gypsum-Fiber Roof Board One or more layers min. 1.5-inch ISO 95+, optional min. 0.5-inch Tapered ISO 95+ ; Min. 0.5-inch FiberTop C or S or Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board Hot asphalt or I.S.O. Stick / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC-, WB-S, WB-P XR / XR- Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 10 of 48

15 ULTRAPLY TPO SYSTEMS SC-46. SC-47. SC-48. SC-49. SC-50. SC-51. SC-52. SC-53. SC-54. SC-55. SC-56. SC-57. SC-58. SC-59. steel or strutural steel or strutural steel or strutural Min. 22 ga., type B, 50 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel or strutural steel or strutural steel or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel or strutural steel or strutural Min. 22 ga., type B, 50 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. or strutural TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER One or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid (Optional for Recover) Min. 0.5-inch thick, one or more layers, any combination, loose laid One or more layers, any combination, loose laid One or more layers, any combination, loose laid Top Insulation Layer Type Fasten Attach Min. 2-inch ISO 95+ Note 2 Min inch ISO 95+ Note 2 Note 2 Min. 2-inch ISO 95+ Note 2 Min. 2-inch ISO 95+ Note 2 Min. 1.5-inch Note 2 Min. 1-inch Note 2 Min. 1.5-inch ISOGARD HD Composite Min. 1.5-inch ISOGARD HD Composite Note 2 Note 2 Min. 0.5-inch ISOGARD HD Note 2 Min. 0.5-inch ISOGARD HD Note 2 Min. 0.5-inch Dens Prime Min inch SECUROCK Min inch SECUROCK Note 2 Note 2 Note 2 1 per 4 ft 2 / UP-, LVOC--1168, LVOC- 1 per / UP-, LVOC--1168, 2.67 ft 2 LVOC-, WB-S, WB-P 1 per 2 ft 2 / UP-, LVOC--1168, LVOC- 1 per / UP-, LVOC--1168, 2.67 ft 2 LVOC- 1 per / UP-, LVOC--1168, 2.67 ft 2 LVOC- 1 per / UP-, LVOC--1168, 2.67 ft 2 LVOC-, WB-S, WB-P 1 per 2 ft 2 1 per 4 ft 2 / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC-, WB-S, WB-P per 2 / WB-S, WB-P ft 1 per 2 / UP-, LVOC ft 1 per 2 / WB-S, WB-P ft 1 per / UP-, LVOC-, 2.67 ft 2 WB-S 1 per 2 ft 2 / UP-, LVOC--1168, LVOC-, WB-S, WB-P 1 per / UP-, LVOC--1168, 1.78 ft 2 LVOC Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 11 of 48

16 SC-60. SC-61. SC-62. SC-63. SC-64. SC-65. SC-66. SC-67. SC-68. SC-69. SC-70. SC-71. SC-72. steel; 6 spans; Traxx/5 screw 6 o.c. Min. 22 ga., type B, 50 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. steel; 6 spans; 5/8 puddle weld 6 o.c. or strutural Min. 22 ga., type B, 50 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural ; 6 spans; Traxx/5 screw 6 o.c. steel or strutural ; 6 spans; Traxx/5 screw 6 o.c. steel or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Min. 1.5-inch thick, one or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid One or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid Top Insulation Layer Type Fasten Attach Min. 19/32-inch plywood Min. 1-inch Note 2 Min. 19/32-inch plywood Note 2 Min. 0.5-inch SECUROCK Firestone HD HailGard Fastener Firestone HD HailGard Fastener Note 2 Min. 0.5-inch ISOGARD HD Note 2 Min. 1-inch ISOGARD HD Composite Min. 0.5-inch Dens Prime or SECUROCK Min. 19/32-inch plywood Note 2 Note 2 Min. 2-inch ISO 95+ Note 2 Min. 1.5-inch Note 2 Min. 2-inch Note 2 Min. 2-inch Note 2 Firestone Insulation Fastening Plates Firestone HD Fasteners or Firestone Concrete Drive ( only) 1 per 2 / UP-, LVOC ft 1 per 1.6 ft 2 / UP-, LVOC--1168, LVOC per / UP-, LVOC ft 1 per 2 / UP-, LVOC ft 1 per / UP-, LVOC--1168, 1.78 ft 2 LVOC- 1 per / UP-, LVOC--1168, 1.33 ft 2 LVOC- 1 per / UP-, LVOC--1168, 1.33 ft 2 LVOC per 2 / UP-, LVOC ft 1 per 2 2 / UP-, LVOC ft 1 per / UP-, LVOC ft 1 per 1.6 ft 2 / UP-, LVOC--1168, LVOC per 1 2 / WB-S, WB-P ft 1 per 1.6 ft 2 / UP-, LVOC--1168, LVOC Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 12 of 48

17 SC-73. SC-74. SC-75. SC-76. SC-77. SC-78. SC-79. SC-80. SC-81. SC-82. SC-83. SC-84. Min. 22 ga., type B, 60 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural Min. 22 ga., type B, Grade 80 steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural Min. 22 ga., type B, Grade 80 steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural ULTRAPLY TPO XR SYSTEMS SC-85. steel or strutural TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER One or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid Min. 1.5-inch thick, one or more layers, any combination, loose laid One or more layers, any combination, loose laid Top Insulation Layer Type Fasten Attach Min. 0.5-inch SECUROCK Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 13 of 48 Note 2 Note 2 Min. 2-inch Note 2 Min. 0.5-inch Dens Prime or SECUROCK Note 2 Min. 2-inch ISO 95+ Note 2 Min. 2-inch Note 2 Min. 1.5-inch ISOGARD HD Composite Min. 0.5-inch SECUROCK Min. 2-inch ISOGARD HD Composite Note 2 Note 2 Note 2 Min. 2-inch ISO 95+ Note 2 Min. 2-inch Note 2 Min. 19/32-inch plywood Min inch Dens Prime or min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board Firestone Insulation Fastening Plates Firestone HD Fasteners or Firestone Concrete Drive ( only) Note 2 1 per 2 / UP ft 1 per 2 / UP-, LVOC ft 1 per / UP-, LVOC--1168, 1.33 ft 2 LVOC per 1 2 / UP-, LVOC ft 1 per 1 2 / UP ft 1 per 1 ft 2 / UP-, LVOC--1168, LVOC- 1 per / UP-, LVOC--1168, 1.33 ft 2 LVOC- 1 per 1 ft 2 / UP-, LVOC--1168, LVOC- 1 per / UP-, LVOC--1168, 1.33 ft 2 LVOC per 1 2 / UP ft 1 per 1 ft 2 / UP-, LVOC--1168, LVOC per 1 2 / UP-, LVOC ft 1 per 2 XR / XR ft

18 SC-86. SC-87. SC-88. SC-89. SC-90. SC-91. SC-92. SC-93. steel or strutural steel or strutural steel or strutural steel or strutural steel or strutural steel or strutural steel; 6 spans; Traxx/5 screw 6 o.c. or strutural steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or strutural TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER One or more layers, any combination, loose laid One or more layers, any combination, loose laid One or more layers, any combination, loose laid (optional for recover) One or more layers, any combination, loose laid Top Insulation Layer Type Fasten Attach Min. 0.5-inch FiberTop C or S wood fiber Note 2 Note 2 Min inch ISO 95+ Note 2 Min inch Dens Prime or SECUROCK or min. 19/32-inch plywood Note 2 Min. 0.5-inch ISOGARD HD Note 2 Min. 0.5-inch ISOGARD HD Note 2 Min. 2-inch ISO 95+ Note 2 Min. 2-inch ISO 95+ Note 2 1 per 2 2 XR / XR- ft 1 per 2 ft 2 1 per 4 ft 2 1 per 2 ft 2 1 per 2.1 ft 2 1 per 2 ft 2 1 per 1.6 ft 2 1 per 1 ft 2 XR / Stick, 12- XR / Stick, 12- XR / Stick, 12- XR / Stick, 12- XR / Stick, 4- XR / Stick, 6- XR / Stick, Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 14 of 48

19 SC-94. SC-95. SC-96. SC-97. SC-98. SC-99. Min. 22 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi Min. 22 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi Min. 22 ga., type B, 50 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. or min. 2,500 psi Min. 22 ga., type B, 50 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. or min. 2,500 psi Min. 22 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi Vapor & Air Barrier (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 V-Force with min. 3-inch side laps self-adhered to top flanges of steel deck Min inch SECUROCK Gypsum-Fiber Roof Board followed by V-Force with min. 3-inch side laps self-adhered (Optional) Note 19 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER Insulation One or more layers, any combination, preliminarily attached One or more layers, any combination, preliminarily attached One or more layers, any combination Min. 2.5-inch ISO 95+, or ISOGARD HD Composite Min. 2.5-inch ISO 95+, or ISOGARD HD Composite One or more layers, any combination Fasten Firestone Heavy Duty Fasteners or Firestone Concrete Drive ( only) and InvisiWeld Plates Firestone Heavy Duty Fasteners or Firestone Concrete Drive ( only) and InvisiWeld Plates Firestone Heavy Duty Fasteners and UltraPly TPO InvisiWeld Plates Firestone Heavy Duty Fasteners and UltraPly TPO InvisiWeld Plates Firestone Heavy Duty Fasteners and UltraPly TPO InvisiWeld Plates Firestone Heavy Duty Fasteners and UltraPly TPO InvisiWeld Plates Attach Density / Pattern Max. 12- in rows max. 60- Max. 6- in rows max per 5.33 ft² (6 parts per 4x8 ft board) Per FM LPDS 1-29 / RAS per 4 ft² (8 parts per 4x8 ft board) in a 24 x 24-inch grid 1 per 4 ft² (8 parts per 4x8 ft board) in a 24 x 24-inch grid 1 per 4 ft² (8 parts per 4x8 ft board) Per FM LPDS 1-29 / RAS 117 Roof Cover bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 15 of 48

20 SC-100. SC-101. SC-102. Min. 22 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi Min. 22 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screws 6 o.c., or Min. 22 ga., type B, 60 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. or min. 2,500 psi Min. 22 ga., type B, Grade 33 steel; 6 spans; two (2) Traxx/5 screws 6 o.c. or min. 2,500 psi Vapor & Air Barrier (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 TABLE 2D: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER Insulation One or more layers, any combination One or more layers, any combination One or more layers, any combination Fasten Firestone Heavy Duty Fasteners with alternating Rows of: 1.) Firestone UltraPly TPO InvisiWeld Plates 2.) Firestone Insulation Fastening Plates Firestone Heavy Duty Fasteners and UltraPly TPO InvisiWeld Plates Firestone Heavy Duty Fasteners and UltraPly TPO InvisiWeld Plates Attach Density / Pattern 1 per 2 ft² (16 parts per 4x8 ft board) in a 12 x 24-inch grid 1 per 2.7 ft² (12 parts per 4x8 ft board) Per FM LPDS 1-29 / RAS per 2 ft² (16 parts per 4x8 ft board) Per FM LPDS 1-29 / RAS 117 Roof Cover bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 16 of 48

21 SC-103. SC-104. SC-105. SC-106. SC-107. SC-108. SC-109. SC-110. steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. or Min. 22 ga., type B, 60 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, 60 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER (STRESS PLATES) Vapor & Air Barrier (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 V-Force with min. 3- inch side laps selfadhered to top flanges of steel deck (Optional) Note 19 Insulation Roof Cover Type Attach Membrane Fasten Attach Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 0.5-inch ISO 95+, or ISOGARD HD Min. 1.5-inch thick, one or more layers, any combination Prelim. attached Prelim. attached Prelim. attached Prelim. attached Prelim. attached Prelim. attached Note 2 (HD only) 1 per 8 ft 2 24x72-inch grid Prelim. attached or TPO XR Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates or UltraPly TPO Barbed Seam Plates Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone HD Plus Seam Plates Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone HD Plus Seam Plates or Wide Weld Seam Plates Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone HD Plus Seam Plates Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates or UltraPly TPO Wide Weld Seam Plates Firestone HD Fasteners with Firestone HD Seam Plates Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates or UltraPly TPO Barbed Seam Plates 12- within 6-inch wide laps spaced 72- Laps sealed with 1.5-inch heat weld. 12- within 6-inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld. 12- within 6-inch wide laps spaced 114-inch o.c. Laps sealed with 5-inch heat weld that encapsulates plates. 12- within 6-inch wide laps spaced 90- Laps sealed with 1.5-inch heat weld. 12- within 6-inch wide laps spaced 90- Laps sealed with 1.5-inch heat weld. 12- within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates plates. 12- within 6-inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 72- Laps sealed with 1.5-inch heat weld Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 17 of 48

22 SC-111. SC-112. SC-113. SC-114. SC-115. SC-116. SC-117. SC-118. steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, 50 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. Min. 22 ga., type B, 60 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. Min. 22 ga., type B, Grade 80 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, 50 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. steel; 6 spans; 5/8 puddle weld 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. or Min. 22 ga., type B, 60 ksi steel; 6 spans; 5/8 puddle welds 6 o.c. or min. 2,500 psi structural TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER (STRESS PLATES) Vapor & Air Barrier (Optional) Note 19 Min inch SECUROCK Gypsum- Fiber Roof Board followed by V-Force with min. 3-inch side laps self-adhered V-Force with min. 3- inch side laps selfadhered to top flanges of steel deck (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 (Optional) Note 19 Insulation Roof Cover Type Attach Membrane Fasten Attach Min. 1.5-inch thick, one or more layers, any combination Min. 3-inch ISO 95+ Min. 0.5-inch ISO 95+, or ISOGARD HD Min. 1.5-inch thick, one or more layers, any combination Min. 0.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Prelim. attached Note 2 (HD only) 1 per 4 ft 2 24x24-inch grid Note 2 (HD only) 1 per 5.3 ft 2 24x36-inch grid, 12-inch from board edges Loose Laid Prelim. attached Prelim. attached Prelim. attached Prelim. attached or TPO XR (min. 60-mil) or TPO XR Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates Firestone HD Fasteners with Firestone HD Seam Plates Firestone HD Fasteners with Firestone HD Seam Plates Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates Firestone HD Fasteners with Firestone HD Seam Plates Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone HD Plus Seam Plates Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone HD Plus Seam Plates 6- within 6-inch wide laps spaced 114- Laps sealed with 1.5-inch heat weld. 12- within 6-inch wide laps spaced 114-inch o.c. Laps sealed with 1.5-inch heat weld. 12- within 6-inch wide laps spaced 142-inch o.c. Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 142- Laps sealed with 1.5-inch heat weld. 6- within 7-inch wide laps spaced 89- Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 114- Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 142- Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 114- Laps sealed with 1.5-inch heat weld Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 18 of 48

23 SC-119. SC-120. SC-121. steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, 60 ksi steel; 6 spans; #12-24 x 1-1/4 HWH screw 6 o.c. Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural TABLE 2E: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER (STRESS PLATES) Vapor & Air Barrier (Optional) Note 19 Two (2) layers, V- Force with min. 3- inch side laps selfadhered (Optional) Note 19 Insulation Roof Cover Type Attach Membrane Fasten Attach Min. 1.5-inch thick, one or more layers, any combination Min. 3-inch ISO 95+, or ISOGARD HD Composite Min. 1.5-inch thick, one or more layers, any combination Prelim. attached Note 2 (HD only) 1 per 5.3 ft 2 24x36-inch grid, 12-inch from board edges Prelim. attached Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone HD Plus Seam Plates Firestone HD Fasteners with Firestone HD Seam Plates Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone HD Plus Seam Plates 6- within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates plates. 12- within 6-inch wide laps spaced 142-inch o.c. Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates plates Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 19 of 48

24 SC-122. SC-123. SC-124. SC-125. SC-126. SC-127. SC-128. SC-129. SC-130. steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER (TTENS) Insulation Roof Cover Type Attach Type Fasten Attach Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Prelim. attached Prelim. attached Prelim. attached Loose Laid Prelim. attached Prelim. attached Prelim. attached Prelim. attached Prelim. attached UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone Polymer Batten Strip Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone Coiled Metal Batten Strip UltraPly QuickSeam R.M.A. Strips with Firestone HD Fasteners with Firestone Coiled Metal Batten Strip Firestone HD Fasteners with Firestone Coiled Metal Batten Strip Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone Batten Strip or Coiled Metal Batten Strip Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone Polymer Batten Strips Firestone HD Plus Fasteners (steel only) with Firestone Coiled Metal Batten Strip Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone Coiled Metal Batten Strip or Firestone Polymer Batten Strip Firestone HD Plus Fasteners (steel only) with Firestone Coiled Metal Batten Strip Fasteners 12- through batten within 6-inch wide laps spaced 114- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 12- through batten within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates batten. UltraPly QuickSeam R.M.A. Strips are applied over the insulation spaced 120- The batten is centered over each strip and fastened 6- Roof cover adhered to each strip by first priming with QuickPrime at the strip location, then rolling into place with a hand roller. Fasteners 6- through batten within 6-inch wide laps spaced 142- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten in field of the roof spaced 144- Battens sealed with 5-inch wide cover strip, with 1.5-inch heat weld on each side of the strip or by applying Firestone TPO QuickSeam Flashing atop batten. Fasteners 6- through batten within 6-inch wide laps spaced 114- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 142- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 114- Laps sealed with 5-inch heat weld that encapsulates batten Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 20 of 48

25 SC-131. SC-132. SC-133. SC-134. SC-135. SC-136. SC-137. SC-138. Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural Min. 22 ga., type B, Grade 80 steel; 6 spans; Traxx/5 screw 6 o.c. Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. Min. 22 ga., type B, Grade 80 steel or min. 20 ga., type B, Grade 33 steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. or min. 2,500 psi structural steel; 6 spans; Traxx/5 screw 6 o.c. Min. 22 ga., type B, Grade 80 steel; 6 spans; Traxx/5 screw 6 o.c. TABLE 2F: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER (TTENS) Insulation Roof Cover Type Attach Type Fasten Attach Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Min. 0.5-inch Dens, Dens Prime or SECUROCK Gypsum-Fiber Roof Board loose laid over min. 1.5-inch thick, one or more layers, any combination Min. 1.5-inch thick, one or more layers, any combination Prelim. attached Prelim. attached Loose Laid Prelim. attached Prelim. attached Prelim. attached Prelim. attached Loose Laid UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO UltraPly TPO Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone Batten Strip or Coiled Metal Batten Strip or Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone Polymer Batten Strip Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone Batten Strip or Coiled Metal Batten Strip Firestone HD Plus Fasteners (steel only) with Firestone ¾ Polymer Batten Strips Firestone HD Fasteners with Firestone Coiled Metal Batten Strip Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone Batten Strip or Coiled Metal Batten Strip Firestone HD Plus Fasteners (steel only) or Firestone Concrete Drive ( only) with Firestone Coiled Metal Batten Strip Firestone HD Plus Fasteners (steel only) with Firestone Coiled Metal Batten Strip Firestone HD Plus Fasteners (steel only) with Firestone ¾ Polymer Batten Strips Fasteners 6- through batten within 6-inch wide laps spaced 114- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 68- Laps sealed with 5-inch heat weld that encapsulates battens. Fasteners 6- through batten within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 90- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 54- Laps sealed with 5-inch heat weld that encapsulates batten. Fasteners 6- through batten within 6-inch wide laps spaced 54- Laps sealed with 5-inch heat weld that encapsulates batten. Lap Row: Fasteners 6- through battens within 6-inch wide laps spaced 142- Laps sealed with 5-inch heat weld that encapsulates the batten. Field Row: Fasteners 6- through battens in one intermediate row between laps. Batten strips covered with 5-inch wide strips sealed on both sides with 1.5-inch heat weld Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 21 of 48

26 ULTRAPLY TPO SYSTEMS C-1 C-2 C-3 C-4 C-5 C-6 C-7 C-8 C-9 C-10 C-11 C-12 structural structural structural structural structural structural structural structural structural structural structural structural Primer ASTM D41 ASTM D41 ASTM D41 ASTM D41 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 17 FOR VAPOR RRIER OPTIONS Top Insulation Layer Type Attach Type Attach with optional Tapered ISO 95+ with optional Tapered ISO 95+ with optional Tapered ISO 95+ Min. 1.5-inch Min. 1.5-inch Min. 1.5-inch Min. 1.5-inch Min. 1-inch Hot Asphalt Min. 0.5-inch Firestone FiberTop Hot Asphalt Hot Asphalt (Optional) Tapered ISO 95+ Hot asphalt Hot Asphalt Hot Asphalt I.S.O. I.S.O., 8- I.S.O., 4- I.S.O. I.S.O., 8- I.S.O., 6- I.S.O., 6- I.S.O. Min inch Dens, Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK (Optional) Additional layers of base insulation (Optional) Additional layers of base insulation (Optional) Additional layers of base insulation (Optional) Additional layers of base insulation (Optional) Additional layers of base insulation (Optional) Additional layers of base insulation (Optional) Additional layers of base insulation Min. 1-inch / UP-, LVOC / UP-, LVOC * * Hot Asphalt / UP * Hot Asphalt / LVOC *, 8-, 4-, 8-, 6-, 6- / UP-, LVOC , LVOC- / UP-, LVOC / UP-, LVOC * * * / WB-S, WB-P * / WB-S, WB-P * / WB-S, WB-P * / UP-, LVOC , LVOC * / LVOC * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 22 of 48

27 C-13 C-14 C-15 C-16 C-17 C-18 C-19 C-20 C-21 C-22 C-23 C-24 C-25 C-26 structural structural structural structural structural structural structural structural structural structural structural structural structural structural Primer TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 17 FOR VAPOR RRIER OPTIONS Top Insulation Layer Type Attach Type Attach Min. two layers min. 1.5-inch ISO 95+ Two layers min. 1.5-inch ISO 95+ Min. two layers min. 1.5-inch ISO 95+ One or more layers, min. 1.5-inch ISO 95+ One or more layers, min. 1.5-inch ISO 95+ Min. 0.5-inch ISOGARD HD I.S.O. I.S.O. I.S.O. I.S.O., 8- I.S.O., 8- I.S.O. I.S.O., 4- I.S.O. I.S.O. I.S.O. I.S.O. Min. 0.5-inch FiberTop C or S Min inch Dens Prime or SECUROCK Min inch Dens or SECUROCK Gypsum- Fiber Roof Board Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK insulation or min. 1-inch ISO 95+ or 0.5-inch Tapered ISO 95+; Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK Min. 0.5-inch ISOGARD HD Min. 0.5-inch ISOGARD HD, 8-, 8-, 4- ICP CR-20 (Optional) Additional layers base insulation ICP CR-20 ICP CR-20 ICP CR-20 Min inch Dens or SECUROCK Gypsum- Fiber Roof Board Min inch Dens Prime or SECUROCK Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 23 of 48 N/A / LVOC * / UP-, LVOC * / UP * / UP-, LVOC * / UP * / WB-S * / UP-, LVOC * / LVOC * / WB-S, WB-P * / UP-, LVOC / UP-, LVOC , WB-S, WB-P / UP-, LVOC * * * ICP CR-20 / UP * ICP CR-20 / UP-, LVOC *

28 C-27 C-28 C-29 C-30 C-31 C-32 C-33 C-34 C-35 C-36 C-37 C-38 C-39 C-40 structural structural structural structural structural structural structural structural structural structural structural structural structural structural Primer TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 17 FOR VAPOR RRIER OPTIONS Top Insulation Layer Type Attach Type Attach (Optional) Additional layers of base insulation / UP-, LVOC Min. 1.5-inch (Optional) Additional layers of base insulation / WB-S, WB-P * Min. 1.5-inch Min. 1.5-inch, 6- (Optional) Additional layers of base insulation, 6-inch o.c * / WB-S, WB-P * (Optional) Additional layers of base insulation / UP *, 6- (Optional) Additional layers of base insulation, 6-inch o.c. / UP-, LVOC , LVOC- Min. 1-inch Min. 1-inch / LVOC * Min. two layers min. 1.5-inch ISO 95+ Min. two layers min. 1.5-inch ISO 95+ One or more layers, min. 1.5-inch ISO 95+ One or more layers, min. 1.5-inch ISO 95+ Min. 1.5-inch * Min. 0.5-inch FiberTop C or S / LVOC * Min inch Dens, Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK insulation or min. 1-inch ISO 95+ or 0.5-inch Tapered ISO 95+; Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK / UP * / LVOC * / WB-S * / LVOC * Min. 0.5-inch ISOGARD HD / WB-S, WB-P * Min. 0.5-inch ISOGARD HD, 6- Min. 0.5-inch ISOGARD HD, 6-inch o.c. / UP-, LVOC / UP-, LVOC , LVOC * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 24 of 48

29 C-41 C-42 C-43 C-44 C-45 C-46 C-47 C-48 C-49 C-50 C-51 C-52 C-53 C-54 structural structural structural structural structural structural structural structural structural structural structural structural structural structural Primer TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 17 FOR VAPOR RRIER OPTIONS Top Insulation Layer Type Attach Type Attach Min. 0.5-inch ISOGARD HD Min. 1.5-inch Min. 1.5-inch insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min. 19/32-inch plywood N/A I.S.O. FIX II, 6- I.S.O. FIX II, 6- (Optional) Additional layers of base insulation (Optional) Additional layers of base insulation Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 25 of 48 I.S.O. FIX II, 6-inch o.c. I.S.O. FIX II, 6-inch o.c. / UP-, LVOC , LVOC-, WB-S, WB-P / UP-, LVOC , WB-S, WB-P * * / WB-S, WB-P * / UP-, LVOC , LVOC- Min. 1-inch I.S.O. FIX II Min. 1-inch I.S.O. FIX II / LVOC * ULTRAPLY TPO XR SYSTEMS IN XR BONDING ADHESIVE Min. two layers min. 1.5-inch ISO 95+ Min. two layers min. 1.5-inch ISO 95+ One or more layers, min. 1.5-inch ISO 95+ Min. 0.5-inch ISOGARD HD Min. 0.5-inch ISOGARD HD One or more layers, min. 1.5-inch ISO 95+ Min. 1.5-inch Min. 0.5-inch ISOGARD HD * I.S.O. FIX II Min. 0.5-inch FiberTop C or S I.S.O. FIX II / LVOC * I.S.O. FIX II I.S.O. FIX II insulation or min. 1-inch ISO 95+ or 0.5-inch Tapered ISO 95+; Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK I.S.O. FIX II / WB-S * I.S.O. FIX II / LVOC * I.S.O. FIX II Min. 0.5-inch ISOGARD HD I.S.O. FIX II / WB-S, WB-P * I.S.O. FIX II, 4- I.S.O. FIX II, 4- N/A / WB-S, WB-P * I.S.O. FIX II Min. 0.5-inch ISOGARD HD I.S.O. FIX II I.S.O. FIX II, 6- I.S.O. FIX II, 4- Min. 0.5-inch ISOGARD HD N/A I.S.O. FIX II, 6-inch o.c. / UP-, LVOC / UP-, LVOC / UP-, LVOC , LVOC * * * N/A / LVOC *

30 C-55 C-56 C-57 C-58 C-59 C-60 structural structural structural structural structural structural Primer ASTM D41 ASTM D41 ULTRAPLY TPO XR SYSTEMS IN HOT ASPHALT C-61 C-62 C-63 C-64 C-65 structural structural structural structural structural (Optiona l) ASTM D41 (Optiona l) ASTM D41 ASTM D41 (Optiona l) ASTM D41 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 17 FOR VAPOR RRIER OPTIONS Top Insulation Layer Type Attach Type Attach Min inch Dens Prime or SECUROCK Gypsum- Fiber Roof Board One or two layers min. 1.5-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min inch Dens Prime or SECUROCK Gypsum- Fiber Roof Board Hot Asphalt N/A XR / XR * Hot Asphalt I.S.O. ; I.S.O. ; I.S.O. Min inch Dens Prime or SECUROCK (Optional) Additional layer of base insulation or min. 0.5-inch Tapered ISO 95+ insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK Hot Asphalt XR / XR * ; I.S.O. Stick ; I.S.O. Stick XR / XR * XR / XR * XR / XR * XR / XR * Hot Asphalt N/A XR / Hot Asphalt * Hot asphalt (Optional) Additional layers of base insulation Hot asphalt XR / Hot Asphalt * Hot Asphalt N/A XR / Hot Asphalt * Hot Asphalt N/A XR / Hot Asphalt * Hot Asphalt Min inch Dens Prime or SECUROCK Hot Asphalt XR / Hot Asphalt * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 26 of 48

31 C-66 C-67 C-68 structural structural structural Primer (Optiona l) ASTM D41 ULTRAPLY TPO XR SYSTEMS IN I.S.O. SPRAY R OR XR STICK: C-69 C-70 C-71 C-72 C-73 C-74 C-75 structural structural structural structural structural structural structural TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 17 FOR VAPOR RRIER OPTIONS Top Insulation Layer Type Attach Type Attach Two layers min. 1.5-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Hot Asphalt I.S.O. I.S.O. ; I.S.O. ; I.S.O. ; I.S.O. ; I.S.O. ; I.S.O. ; I.S.O. ; Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base insulation or min. 0.5-inch Tapered ISO 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered ISO 95+ insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 27 of 48 Hot Asphalt XR / Hot Asphalt * XR / Hot Asphalt * XR / Hot Asphalt * ; I.S.O. Stick ; I.S.O. Stick ; I.S.O. Stick ; I.S.O. Stick ; I.S.O. Stick ; I.S.O. Stick ; I.S.O. Stick XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 4- (full coverage) XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 6- XR / I.S.O. Spray R or XR Stick, 4- (full coverage) XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, * * -82.5* * -60.0*

32 TABLE 3A: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER REFER TO NOTE 17 FOR VAPOR RRIER OPTIONS C-76 C-77 C-78 C-79 structural structural structural structural Primer Top Insulation Layer Type Attach Type Attach Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch Insulfoam EPS (2 pcf) (Optional) Min. 1-inch ISO 95+ I.S.O. ; I.S.O. ; I.S.O. Spray R insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 19/32-inch plywood Min inch Dens Prime or SECUROCK ; I.S.O. Stick ; I.S.O. Stick I.S.O. Spray R I.S.O. Spray R Min. 0.5-inch Dens Prime I.S.O. Spray R XR / I.S.O. Spray R or XR Stick, 4- (full coverage) XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 4- XR / I.S.O. Spray R, * * TABLE 3B: STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Primer Base Ply Application Top Ply Application C-80 structural N/A XR XR Stick, * C-81 structural N/A XR XR Stick, * C-82 structural ASTM D41 N/A XR XR * C-83 structural N/A XR XR * C-84 structural ASTM D41 N/A XR Hot asphalt * C-85 structural N/A XR I.S.O. Spray R, * C-86 structural N/A XR Hot asphalt * C-87 structural ASTM D41 N/A XR Hot asphalt * C-88 structural ASTM D41 C-89 structural ASTM D41 C-90 structural ASTM D41 One or two plies Firestone Type IV (4) M or Type VI (6) M or one ply of MB Base, SBS Base, SBS PolyBase or SBS Premium Base One or two plies Firestone Type IV (4) M or Type VI (6) M or one ply of MB Base, SBS Base, SBS PolyBase or SBS Premium Base One or two plies Firestone Type IV (4) M or Type VI (6) M or one ply of MB Base, SBS Base, SBS PolyBase or SBS Premium Base Hot asphalt XR I.S.O. Spray R, * Hot asphalt XR XR Stick, * Hot asphalt XR I.S.O. Spray R, * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 28 of 48

33 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER LWC-1 LWC-2 LWC-3 LWC-4 LWC-5 LWC-6 LWC-7 Lightweight Concrete (Note 15) Coverboard Type Attach Type Attach Min. 1-inch ISO 95+ Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ (Optional) Additional layer of base 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK 95+ followed by min. 19/32-inch plywood (Optional) Additional layer of base 95+ / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC- / WB- S, WB-P * * * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 29 of 48

34 LWC-8 LWC-9 LWC-10 LWC-11 LWC-12 LWC-13 LWC-14 LWC-15 Lightweight Concrete (Note 15) Min. 200 psi, min. 2-inch thick Celcore, Elastizell, Mearlcrete or Insulcel cellular LWIC. TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Coverboard Type Attach Type Attach Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered Min. 1-inch ISO 95+ Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered (Optional) Additional layers of base insulation Min. 2-inch ISOGARD HD Composite / WB- S, WB-P / WB- S, WB-P / WB- S, WB-P / WB- S, WB-P / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC * * * * * * / UP * / UP-, LVOC--1168, LVOC * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 30 of 48

35 LWC-16 LWC-17 LWC-18 LWC-19 LWC-20 LWC-21 LWC-22 LWC-23 Lightweight Concrete (Note 15) Min. 200 psi, min. 2-inch thick Celcore, Elastizell, Mearlcrete or Insulcel cellular LWIC. TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Coverboard Type Attach Type Attach Min. 1-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK 95+ followed by min. 19/32-inch plywood (Optional) Additional layer of base 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC * * / UP * Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD / UP-, LVOC--1168, LVOC- / WB- S, WB-P / WB- S, WB-P / WB- S, WB-P / WB- S, WB-P * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 31 of 48

36 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER LWC-24 LWC-25 LWC-26 LWC-27 LWC-28 LWC-29 LWC-30 Lightweight Concrete (Note 15) Coverboard Type Attach Type Attach Min. 1-inch ISO 95+ Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered Min. 1-inch ISO followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base 95+ / WB- S, WB-P XR / XR- XR / XR- XR / XR- XR / XR- XR / XR- XR / Stick, * * * * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 32 of 48

37 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER LWC-31 LWC-32 LWC-33 LWC-34 LWC-35 LWC-36 LWC-37 Lightweight Concrete (Note 15) Coverboard Type Attach Type Attach Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered Min. 1-inch ISO 95+ (Optional) Min inch Tapered ISO 95+ or Tapered (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK 95+ followed by min. 19/32-inch plywood Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD XR / Stick, 12- XR / Stick, 12- XR / Stick, 12- XR / Stick, 12- XR / Stick, 12- XR / Stick, 6- XR / Stick, * -82.5* -82.5* Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 33 of 48

38 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER LWC-38 LWC-39 LWC-40 LWC-41 LWC-42 LWC-43 LWC-44 Lightweight Concrete (Note 15) Coverboard Type Attach Type Attach Min. 1-inch ISO 95+ Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered Min. 1-inch ISO followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base 95+ XR / Stick, 6- XR / Stick, 4- (full coverage) XR / Stick, 4- (full coverage) XR / Stick, 4- (full coverage) XR / Stick, 4- (full coverage) XR / Stick, 4- (full coverage) XR / XR * * * * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 34 of 48

39 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER LWC-45 LWC-46 LWC-47 LWC-48 LWC-49 LWC-50 LWC-51 Lightweight Concrete (Note 15) Coverboard Type Attach Type Attach Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered Min. 1-inch ISO 95+ Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite XR / XR- XR / XR- XR / XR- XR / XR- XR / Stick, 12- XR / Stick, 12- XR / Stick, * * * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 35 of 48

40 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER LWC-52 LWC-53 LWC-54 LWC-55 LWC-56 LWC-57 LWC-58 Lightweight Concrete (Note 15) Coverboard Type Attach Type Attach Min. 1-inch ISO 95+ (Optional) Min inch Tapered ISO 95+ or Tapered Min. 1-inch ISO followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK 95+ followed by min. 19/32-inch plywood Min. 2-inch ISOGARD HD Composite 95+ followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK (Optional) Additional layer of base 95+ XR / Stick, 12- XR / Stick, 12- XR / Stick, 12- XR / Stick, 6- XR / Stick, 6- XR / Stick, 6- XR / Stick, 4- (full coverage) -82.5* -82.5* -60.0* * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 36 of 48

41 LWC-59 LWC-60 LWC-61 LWC-62 LWC-63 LWC-64 LWC-65 LWC-66 LWC-67 LWC-68 LWC-69 LWC-70 Lightweight Concrete (Note 15) Min. 200 psi, min. 2-inch thick Elastizell cellular LWIC. Min. 200 psi, min. 2-inch thick Celcore cellular LWIC. Min. 200 psi, min. 2-inch thick Mearlcrete cellular LWIC. Min. 200 psi, min. 2-inch thick Elastizell cellular LWIC. Min. 200 psi, min. 2-inch thick Celcore or Mearlcrete cellular LWIC. Min. 200 psi, min. 2-inch thick Elastizell cellular LWIC. Min. 200 psi, min. 2-inch thick Celcore cellular LWIC. Min. 200 psi, min. 2-inch thick Mearlcrete cellular LWIC. TABLE 4A: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Coverboard Type Attach Type Attach Min. 1-inch (Optional) Min inch Tapered ISO 95+ or Tapered (Optional) Additional layer of base insulation or min. 0.5-inch Tapered Min. 2-inch ISOGARD HD Composite ICP CR-20 ICP CR-20 ICP CR-20 ICP CR-20 ICP CR-20 ICP CR-20 ICP CR-20 ICP CR followed by min inch ISOGARD HD 95+ followed by Min inch Dens Prime or SECUROCK (Optional) Additional layers base insulation (Optional) Additional layers base insulation (Optional) Additional layers base insulation Min inch Dens or SECUROCK Min inch Dens or SECUROCK Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK XR / Stick, 4- (full coverage) XR / Stick, 4- (full coverage) XR / Stick, 4- (full coverage) XR / Stick, 4- (full coverage) * * * * ICP CR-20 / UP * ICP CR-20 / UP * ICP CR-20 / UP * ICP CR-20 / UP * ICP CR-20 / UP * ICP CR-20 / UP * ICP CR-20 / UP * ICP CR-20 / UP * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 37 of 48

42 LWC-71 Min. 22 ga., type BV (0.5%), 60 ksi steel; 5 spans, 5/8 puddle welds 6 o.c. or min. 2,500 psi structural TABLE 4B: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: MECHANICALLY ATTACHED ROOF COVER (THROUGH LWC TO ENGAGE STRUCTURAL DECK) Lightweight Concrete (Note 15) Min. 200 psi, min. 2-inch thick Elastizell Insulation Roof Cover Type Attach Membrane Fasteners Attachment (Optional) One or more layers, any combination, min inch Prelim. Attach Firestone HD Fasteners or Firestone Concrete Drive ( only) with Firestone HD Seam Plates Fastened through to engage structural deck, 6- within 6-inch wide laps spaced 114- and sealed with a 1.5-inch heat weld ULTRAPLY TPO SYSTEMS: LWC-72 LWC-73 LWC-74 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Lightweight Concrete (Note 15) vented steel deck at max. 6 ft spans; Tek/5 screws 6 o.c. or min. 2,500 psi structural vented steel deck at max. 5 ft spans; Tek/5 screws 6 o.c. or min. 2,500 psi structural structural ULTRAPLY TPO XR SYSTEMS: LWC-75 LWC-76 LWC-77 LWC-78 LWC-79 vented steel deck at max. 6 ft spans; Tek/5 screws 6 o.c. or min. 2,500 psi structural vented steel deck at max. 6 ft spans; 5/8 puddle welds with washer 6 o.c. or min. 2,500 psi structural vented steel deck at max. 6 ft spans; Tek/5 screws 6 o.c. or min. 2,500 psi structural structural vented steel deck at max. 6 ft spans; 5/8 puddle welds with washers 6 o.c. Min. 200 psi, min. 2-inch thick Approved cellular LWIC with optional 1-inch thick, 1.0 pcf EPS holey board. / UP * Min. 200 psi, min. 2-inch thick Approved cellular LWIC with optional 1-inch thick, 1.0 pcf EPS holey board. When walkable, LWC is mechanically attached with Firestone Insulation Fastening Plates with Firestone HD Fasteners at a density of 1 per 2 ft 2. Admixture, with optional 1-inch thick, 1.0 pcf EPS Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 38 of 48 / UP * / UP * Min. 200 psi, min. 2-inch thick Celcore cellular LWIC with optional 1-inch thick, 1.0 pcf EPS holey board. XR / XR- Min. 200 psi, min. 2-inch thick Celcore cellular LWIC with optional 1-inch thick, 1.0 pcf EPS holey board. When walkable, LWC is mechanically attached with Firestone Insulation Fastening Plates with Firestone HD Fasteners at a density of 1 per 2 ft 2. Min. 250 psi, min. 2-inch thick Approved cellular LWIC with optional 1-inch thick, 1.0 pcf EPS holey board. When walkable, LWC is mechanically attached with Firestone Insulation Fastening Plates with Firestone HD Fasteners at a density of 1 per 2 ft 2. Note: To qualify the LWIC under this assembly, an ES Products FM-90 Fastener shall achieve a MCRF of 100 lbf when tested per TAS 105. Min. 250 psi, min. 2-inch thick Approved cellular LWIC. Note: To qualify the LWIC under this assembly, an ES Products FM-90 Fastener shall achieve a MCRF of 95 lbf when tested per TAS 105. Admixture, with optional 1-inch thick, 1.0 pcf EPS XR / XR * XR / XR * XR / XR * XR / XR *

43 LWC-80 LWC-81 LWC-82 LWC-83 LWC-84 LWC-85 LWC-86 LWC-87 TABLE 4C: LIGHTWEIGHT CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Lightweight Concrete (Note 15) vented steel deck at max. 6 ft spans; Traxx/5 screws 6 o.c. vented steel deck at max. 5 ft spans; Traxx/5 screws 6 o.c. vented steel deck at max. 6 ft spans; Tek/5 screws 6 o.c. vented steel deck at max. 4 ft spans; Traxx/5 screws 6 o.c. vented steel deck at max. 6 ft spans; Tek/5 screws 6 o.c. structural vented steel deck at max. 6 ft spans; 5/8 puddle welds with washers 6 o.c. structural Admixture, with optional 1-inch thick, 1.0 pcf EPS Admixture, with optional 1-inch thick, 1.0 pcf EPS Min. 300 psi, min. 2-inch thick Elastizell Lightweight Insulating Concrete, with optional 1-inch thick, 1.0 pcf EPS holey board. Admixture, with optional 1-inch thick, 1.0 pcf EPS Admixture, with optional 1-inch thick, 1.0 pcf EPS When walkable, LWC is mechanically attached with Firestone Insulation Fastening Plates with Firestone HD Fasteners at a density of 1 per 2 ft 2. Admixture, with optional 1-inch thick, 1.0 pcf EPS Min. 250 psi, min. 2-inch thick Elastizell Range II Lightweight Insulating Concrete with optional 1-inch thick, 1.0 pcf EPS holey board. When walkable, LWC is mechanically attached with Firestone Insulation Fastening Plates with Firestone HD Fasteners at a density of 1 per 2 ft 2. Min. 250 psi, min. 2-inch thick Elastizell Range II Lightweight Insulating Concrete with 1-inch thick, 1.0 pcf EPS holey board. XR / XR * XR / XR * XR / XR * XR / XR * XR / XR * XR / XR * XR / XR * XR / XR * LWC-88 structural Min. 250 psi, min. 2-inch thick Elastizell Range II Lightweight Insulating Concrete. No EPS holey board. XR / XR * LWC-89 structural Admixture, with optional 1-inch thick, 1.0 pcf EPS XR / XR Stick; 4- (full coverage) -75.0* Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 39 of 48

44 ULTRAPLY TPO SYSTEMS: TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER CWF-1. Tectum CWF-2. Tectum CWF-3. CWF-4. Tectum or Fibroplank Tectum or Fibroplank CWF-5. Tectum I Min. 1-inch ISO 95+ CWF-6. Tectum I Min. 0.5-inch ISO 95+ ULTRAPLY TPO XR SYSTEMS: CWF-7. Tectum I Min. 1-inch ISO 95+ CWF-8. Tectum I Min. 0.5-inch ISO 95+ Top Insulation Layer Type Attach Type Attach ICP CR-20 ICP CR-20 (Optional) Min inch Dens, Dens Prime or SECUROCK (Optional) Min inch Dens Prime or SECUROCK (Optional) Min inch Dens, Dens Prime or SECUROCK (Optional) Min inch Dens Prime or SECUROCK Min. 0.5-inch ISO 95+ Min. 0.5-inch ISO 95+ / UP- / LVOC ICP CR-20 / UP * ICP CR-20 / LVOC / UP-, LVOC , LVOC- / UP-, LVOC , LVOC- XR / XR Stick, 6- XR / XR Stick, * TABLE 5B: CEMENTITOUS WOOD FIBER DECKS - NEW CONSTUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER CWF-9. CWF-10. Tectum Tectum Anchor Sheet Base Insulation Top Insulation Roof Cover (Note Type Fasten Attach Type Attach Type Attach 16) SBS Base, SBS Premium Base, MB Base or APP 160 SBS Base, SBS Premium Base, MB Base or APP 160 Two Piece Locking Nail Two Piece Locking Nail 9- in the min. 2-inch lap and 18- in two, equally spaced center rows 9- in the min. 2-inch lap and 18- in two, equally spaced center rows Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ (Optional) Min inch Dens, Dens Prime or SECUROCK (Optional) Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board / UP- / LVOC Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 40 of 48

45 ULTRAPLY TPO SYSTEMS: G-1. G-2. G-3. G-4. G-5. G-6. G-7. G-8. G-9. (Notes 1 & 12) Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank Existing poured gypsum or gypsum plank ULTRAPLY TPO XR SYSTEMS: G-10. Existing poured gypsum or gypsum plank TABLE 6A: GYPSUM DECKS - REROOF (TEAR-OFF) SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Top Insulation Layer Type Attach Type Attach Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ (Optional) Min inch ISO 95+ Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ (Optional) Min inch ISO 95+ I.S.O. (Optional) Additional layers of base insulation I.S.O. I.S.O. I.S.O. Min inch Dens Prime or SECUROCK Gypsum- Fiber Roof Board Min inch Dens or SECUROCK Gypsum-Fiber Roof Board I.S.O. / UP-, LVOC / UP-, LVOC * * I.S.O. / UP * I.S.O. Min. 0.5-inch ISOGARD HD I.S.O. / UP ICP CR-20 (Optional) Additional layers base insulation ICP CR-20 ICP CR-20 ICP CR-20 Min inch Dens or SECUROCK Gypsum-Fiber Roof Board Min inch Dens Prime or SECUROCK Gypsum- Fiber Roof Board (Optional) Min inch Dens, Dens Prime or SECUROCK (Optional) Min inch Dens Prime or SECUROCK / UP-, LVOC * ICP CR-20 / UP * ICP CR-20 / UP-, LVOC * / UP * I.S.O. Min. 0.5-inch ISOGARD HD I.S.O. / LVOC XR / XR Stick, 4- (full coverage) * TABLE 6B: GYPSUM DECKS - NEW CONSTUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER G-11. G-12. Existing gypsum deck Existing gypsum deck Anchor Sheet Base Insulation Top Insulation Roof Cover Type Fasten (Note 11) Attach Type Attach Type Attach (Note 16) SBS Base, SBS Premium Base, MB Base or APP 160 SBS Base, SBS Premium Base, MB Base or APP 160 Two Piece Locking Nail (MCRF > 105 lbf) Two Piece Locking Nail (MCRF > 105 lbf) 9- in the min. 2-inch lap and 18- in two, equally spaced center rows 9- in the min. 2-inch lap and 18- in two, equally spaced center rows Min. 1.5-inch ISO 95+ Min. 1.5-inch ISO 95+ I.S.O. Stick I.S.O. Stick (Optional) Min inch Dens, Dens Prime or SECUROCK Gypsum-Fiber Roof Board (Optional) Min inch Dens Prime or SECUROCK Gypsum- Fiber Roof Board / UP- / LVOC Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 41 of 48

46 ULTRAPLY TPO SYSTEMS R-1 R-2 R-3 R-4 R-5 R-6 R-7 R-8 R-9 R-10 R-11 R-12 Substrate (Notes 1 & 12) Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Top Insulation Layer Type Attach Type Attach with optional Tapered ISO 95+ Hot Asphalt Min. 0.5-inch Firestone FiberTop Hot Asphalt Hot Asphalt (Optional) Tapered ISO 95+ Hot asphalt with optional Tapered ISO 95+ with optional Tapered ISO 95+ (Optional) Min. 1.5-inch ISO 95+ Min. 1-inch ISO 95+ Min. 1-inch Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Hot Asphalt Hot Asphalt I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. Min inch Dens, Dens Prime or SECUROCK Gypsum- Fiber Roof Board Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board (Optional) Min inch Dens, Dens Prime or SECUROCK Gypsum- Fiber Roof Board (Optional) Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board Min. 0.5-inch ISOGARD HD (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered ISO 95+ (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered ISO 95+ or Tapered insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min. 0.5-inch ISOGARD HD / UP-, LVOC / UP-, LVOC * * Hot Asphalt / UP * Hot Asphalt I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. I.S.O. / LVOC * / UP * / LVOC / UP-, LVOC / WB-S, WB-P / WB-S, WB-P / UP-, LVOC--1168, LVOC- / WB-S, WB-P / UP-, LVOC--1168, LVOC * * * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 42 of 48

47 R-13 R-14 R-15 R-16 R-17 R-18 R-19 R-20 R-21 R-22 R-23 R-24 R-25 Substrate (Notes 1 & 12) Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Top Insulation Layer Type Attach Type Attach Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or I.S.O. I.S.O. I.S.O. insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK I.S.O. I.S.O. I.S.O. ICP CR-20 (Optional) Additional layers base insulation ICP CR-20 / WB-S, WB-P / UP-, LVOC- / UP-, LVOC / UP-, LVOC ICP CR-20 Min inch Dens or SECUROCK ICP CR-20 / UP * Min. 1-inch ISO 95+ Min. 1-inch Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or ICP CR-20 I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered ISO 95+ (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered ISO 95+ or Tapered insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK ICP CR-20 I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II I.S.O. FIX II / UP-, LVOC / WB-S, WB-P / WB-S, WB-P / UP-, LVOC--1168, LVOC- / WB-S, WB-P / UP-, LVOC--1168, LVOC- / WB-S, WB-P / UP-, LVOC--1168, LVOC * * * * * * * * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 43 of 48

48 R-26 R-27 Substrate (Notes 1 & 12) Existing asphaltic BUR or granule surface modified bitumen Existing asphaltic BUR or granule surface modified bitumen R-28 Existing asphaltic BUR R-29 R-30 Existing asphaltic BUR or granule surface modified bitumen R-31 Existing asphaltic BUR R-32 ULTRAPLY TPO XR SYSTEMS R-33 R-34 R-35 R-36 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Top Insulation Layer Type Attach Type Attach Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered ISO 95+ (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered (Optional) Additional layers of base insulation and/or min. 0.5-inch Tapered ISO 95+ or Tapered (Optional) Additional layers of base insulation insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board Hot Asphalt N/A I.S.O. FIX II I.S.O. insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK I.S.O. FIX II I.S.O. / WB-S, WB-P / WB-S, WB-P / UP-, LVOC--1168, LVOC- / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC-, WB-S, WB-P / UP-, LVOC--1168, LVOC-, WB-S, WB-P XR / Hot Asphalt XR / Hot Asphalt XR / Hot Asphalt XR / Hot Asphalt -60.0* -60.0* * -60.0* -60.0* * * * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 44 of 48

49 R-37 R-38 R-39 R-40 R-41 R-42 Substrate (Notes 1 & 12) Existing granule-surfaced, asphaltic modified bitumen R-43 Existing asphaltic BUR R-44 R-45 R-46 Existing asphaltic BUR R-47 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Top Insulation Layer Type Attach Type Attach Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ISOGARD HD Min. 0.5-inch ISOGARD HD Hot Asphalt N/A XR / XR * I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. I.S.O. I.S.O. FIX II I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. Spray R, 6- (Optional) Additional layer of base insulation or min. 0.5-inch Tapered ISO 95+ insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ or Tapered ; Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. I.S.O. XR / XR * XR / XR * XR / XR * XR / XR * I.S.O. FIX II XR / XR * XR / XR * XR / XR * XR / XR * N/A N/A XR / I.S.O. Spray R or XR Stick, 4- XR / I.S.O. Spray R or XR Stick, * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 45 of 48

50 R-48 R-49 R-50 R-51 R-52 R-53 R-54 R-55 R-56 Substrate (Notes 1 & 12) TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1A: BONDED INSULATION, BONDED ROOF COVER Top Insulation Layer Type Attach Type Attach Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or Min. 1-inch ISO 95+ or R-57 Existing asphaltic BUR Min. 1-inch ISO 95+ R-58 Existing asphaltic BUR Min. 0.5-inch ISOGARD HD or Min inch Dens Prime or SECUROCK Gypsum-Fiber Roof Board I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. (Optional) Additional layer of base insulation or min. 0.5-inch Tapered ISO 95+ (Optional) Additional layer of base insulation or min. 0.5-inch Tapered ISO 95+ insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 0.5-inch ISOGARD HD insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by Min inch Dens Prime or SECUROCK insulation or min. 0.5-inch Tapered ISO 95+ followed by min. 19/32-inch plywood (Optional) Min. 0.5-inch ISOGARD HD or Min inch Dens Prime or SECUROCK I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. I.S.O. FIX II; I.S.O. Stick; I.S.O. Spray R; I.S.O. N/A XR / I.S.O. Spray R or XR Stick, 6- XR / I.S.O. Spray R or XR Stick, 4- (full coverage) XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 6- XR / I.S.O. Spray R or XR Stick, 4- (full coverage) XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 6- XR / I.S.O. Spray R or XR Stick, 4- (full coverage) XR / I.S.O. Spray R or XR Stick, 12- XR / I.S.O. Spray R or XR Stick, 4- XR / I.S.O. Spray R or XR Stick, * * -82.5* * -60.0* * * * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 46 of 48

51 TABLE 7B: STEEL - RECOVER SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER Note: All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener into the purlin. R-59 R-60 R-61 Substrate Existing standing seam or lap seam metal roof covers having min. 3/16-inch to max. ¼-inch thick steel purlins spaced max. 60- Existing standing seam or lap seam metal roof covers having min. ¼-inch thick steel purlins spaced max. 120-inch o.c. Existing standing seam or lap seam metal roof covers having min. 3/16-inch to max. ¼-inch thick steel purlins spaced max. 60- Insulation Layer One or more layers, any combination, preliminarily fastened per FM Approvals requirements One or more layers, any combination, preliminarily fastened per FM Approvals requirements One or more layers, any combination, preliminarily fastened per FM Approvals requirements Fasten (Note 11) Attach Firestone Purlin Fasteners and InvisiWeld Plates are fastened through to purlins Firestone Purlin Fasteners and InvisiWeld Plates are fastened through to purlins Firestone Purlin Fasteners and InvisiWeld Plates are fastened through to purlins Spacing 12- along purlins 6- along purlins 6- along purlins Roof Cover bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps. bonded to InvisiWeld Plates with RhinoBond Portable Plate Bonding Tool and weighted RhinoBond Cooling Clamps TABLE 7C: STEEL - RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER Note: All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener into the purlin. R-62 R-63 Substrate Existing standing seam or lap seam metal roof covers having min. 3/16-inch to max. ¼-inch thick steel purlins spaced max. 90- Existing standing seam or lap seam metal roof covers having min. 3/16-inch to max. ¼-inch thick steel purlins spaced max Insulation Roof Cover Type Attach Membrane Fasteners (Note 11) Attach One or more layers, any combination One or more layers, any combination Prelim. attached Prelim. attached Firestone Purlin Fasteners and Firestone HD Seam Plates Firestone Purlin Fasteners and Firestone HD Seam Plates 12- within 6-inch wide laps spaced max. 90- to engage steel purlin. Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced max to engage steel purlin. Laps sealed with 1.5-inch heat weld Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 47 of 48

52 TABLE 7D: STEEL - RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED ROOF COVER (RMA STRIPS) Note: All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener into the purlin. R-64 Substrate (Notes 1) Existing standing seam or lap seam metal roof covers having min. 3/16-inch to max. ¼-inch thick steel purlins spaced max. 10-ft o.c. Insulation Roof Cover Type Attach Membrane Fasten (Note 11) Attach One or more layers, any combination Prelim. attached Firestone Purlin Fasteners and Firestone Coiled Metal Batten Strip Firestone UltraPly QuickSeam R.M.A. Strips are applied over the insulation spaced 120- positioned over each steel purlin location. The batten is centered over each strip and fastened into the purlins 6- Roof cover adhered to each strip by first priming the membrane underside with Firestone QuickPrime at the strip location, then rolling into place with a hand roller. The min. 2-inch side laps are sealed with a min. 1.5-inch outside heat weld R-65 Min. 22 ga., type B, Grade 80 steel XR R-66 steel or min. 2,500 psi structural TABLE 7E: RECOVER APPLICATIONS SYSTEM TYPE E: NON-INSULATED, MECHANICALLY ATTACHED ROOF COVER Roof Cover Type Fasteners (Note 11) Attach XR R-67 Min. 22 ga., type B, Grade 80 steel XR Firestone HD Plus Fasteners (steel only) with Firestone HD Plus Seam Plates Firestone HD Fasteners with Firestone HD Seam Plates Firestone HD Plus Fasteners (steel only) with Firestone HD Plus Seam Plates 12- within 6-inch wide laps spaced 114- Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 114- Laps sealed with 1.5-inch heat weld. 6- within 6-inch wide laps spaced 114- Laps sealed with 1.5-inch heat weld Substrate (Notes 1 & 12) TABLE 7F: RECOVER APPLICATIONS SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER Primer Type Application R-68 Existing asphaltic BUR or granule-surfaced roof cover XR I.S.O. Spray R, XR Stick, 12- R-69 Existing granule-surfaced, asphaltic roof cover XR I.S.O. Spray R, XR Stick, * R-70 Existing asphaltic BUR over structural deck XR XR Stick, * R-71 Existing asphaltic BUR or granule surface over structural XR I.S.O. Spray R, R-72 d SBS over structural deck XR XR Stick, R-73 d APP over structural deck XR XR Stick, R-74 Existing asphaltic BUR or granule surface over structural or steel deck XR Hot asphalt * Prepared by: Robert Nieminen, PE Firestone Single Ply Roof s; (800) Appendix 1, Page 48 of 48