LOW ROOF HIGH ROOF. Typical Roof Expansion Joint Applications Partial Plan View

Size: px
Start display at page:

Download "LOW ROOF HIGH ROOF. Typical Roof Expansion Joint Applications Partial Plan View"

Transcription

1 VERTICL WLL SURFCE LOW ROOF For Typical Splice Details Refer to Dwg's: C for Flush Conditions C for Corner Conditions HIGH ROOF C ROOF COVER PLTE WIDTH JOINT OPENING (See Detail "" Sheet 3) WSW Seismic Wall Expansion Joint System Transitional Splice t Corner (See Detail "C" Sheet 5) Roof To Wall Joint WSW Seismic Wall Expansion Joint System Upturn t Low Roof (See Detail "B" Sheet 4) t High Roof (See Detail "" Sheet 3) Typical Roof Expansion Joint pplications Partial Plan View 1

2 High Roof t Downturn (See Detail "a") Roof To Wall Joint Vertical Wall Surface Transitional Splice t Corner (See Detail "C") Height Of Roof Joint System Height Of Roof Joint System t Downturn (See Detail "") WSW Wall Expansion Joint System To Run Vertically Up To Roof nd Turn Horizontally To Run Below Roof Joint t Upturn (See Detail "B") Typical Roof Expansion Joint pplications Side Section View 2

3 SEE NOTE "B" Sealant (by Others) Face Of Wall ROOF SYSTEM WIDTH - = LENGTH #10 Dia. Hex Head Self-drilling Tek Screw w/ Rubber 6" O.C 6" 1/4" See Note "" Top of Cover Roof Gasket Roof to Wall Detail T EXPNSION JOINT DOWNTURN Factory Tack Weld t To luminum ngle x x 1/8" luminum ngle.08" End Cap Top of Roof Cover Top edge of end Cap Offset To Minimize Lateral Surface Moisture Run-off NOTE "" Grind Screw Smooth w/ Underside of fter Installation SECTION - 6" 1/4" ROOF SYSTEM WIDTH - = LENGTH DETIL "" Details PPLICBLE TO RFL & RFC Roof to Roof Detail T EXPNSION JOINT DOWNTURN NOTE "B" Terminate Roof Gasket From Edge of Roof System to Clear x x 1/8" luminum ngle 3

4 Face Of Wall See Note "B" x x 1/8" luminum ngle Top of Cover ROOF SYSTEM WIDTH - = LENGTH Sealant (by Others) Roof Gasket Roof to Wall Detail T EXPNSION JOINT UPTURN #10 Dia. Hex Head Self-drilling Tek Screw w/ Rubber 6" O.C. Section - Note "" DETIL "B" Details NOTE "" Grind Screw Smooth w/ Underside of fter Installation ROOF SYSTEM WIDTH - = LENGTH NOTE "B" Terminate Roof Gasket from Edge of Roof System to Clear 2 x 1 x 1/8" luminum ngle. Roof to Roof End Cap Detail T EXPNSION JOINT UPTURN 4

5 Roof To Wall Joint System Cover 2 nchors min. req'd. utilize Typical Factory nchor to Field attach Splice plate to Wall Corner of Exterior Wall Splice pply bead of sealant each side prior to mounting splice plate pprox. 1/2 Cover Width 3" 3" 6" Optional Fastener Location On Wide Roof Covers (one Side Only) OPENING Roof To Roof Joint Gap req'd at time of Installation. Roof will migrate over during full open. Gap Will Close During Closure Of The Joint Opening DETIL "C" Transtional Splice 5

6 Splice #10 Dia. Hex Head Self-drilling Tek Screw w\ Rubber Washer at C LRoof Cover (One Side Only) Optional Fastener Location on wide roof Covers (One Side Only) 1/8" Min. Gap Between s During Installation 1/ C L ROOF COVER pply bead of Sealant to each side prior to mounting Splice. Ensure Splice is properly seated on Top of Roof Canal Roof Splice (Flush Condition) 6

7 Roof To Wall Joint System Cover Splice Utilize Typical Factory nchor To Field ttach Splice To Wall. Field Drill Hole For nchor Through Standard Roof Cover Optional Fastener Location On Wide Roof Covers (One Side Only) 5/8" pply bead of Sealant to each side prior to mounting Splice. Ensure Splice is properly seated on Top of Roof Canal Roof Splice (Corner Condition) 7