A. Product Data shall be provided for each type of product indicated.

Size: px
Start display at page:

Download "A. Product Data shall be provided for each type of product indicated."

Transcription

1 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical service and connections for motor operators, controls, limit and disconnect switches, and safety features and for system disconnect switches. 1.2 SUBMITTALS A. Product Data shall be provided for each type of product indicated. B. Shop Drawings shall include fence locations, components, materials, dimensions, sizes, weights, and finishes of components. Include plans, gate elevations, sections, details of post anchorage, attachment, bracing, and other required installation and operational clearances. C. If Gate Operator is required shop drawings shall include locations and details for installing operator components, switches, and controls. Indicate motor size, electrical characteristics, drive arrangement, mounting, and grounding provisions. D. Maintenance Data shall submitted for fence, fence gates, and gate operator (if required). 1.3 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories shall be listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. B. Gate operators shall comply with UL 325. C. Emergency Access Requirements shall comply with requirements of authorities having jurisdiction for all gates and automatic gate operators serving as a required means of access. SECTION 2 PRODUCTS 2.1 CHAIN LINK FENCE FABRIC A. General: 1. Height and other dimensions for the fencing are shown on the drawings and in the Standard Details for Chain Link Fencing. American States Utility Services Chain Link Fences and Gates

2 B. Fence Fabric shall comply with the following: 2.2 FENCE FRAMING 1. ASTM A 392, CLFMI CLF 2445, and requirements indicated below: 2. Steel Wire Fence Fabric shall be: a. Coated wire with a diameter of inch or 9 Gauge. b. 2 inch diamond mesh fence fabric c. Coating for fence fabric shall be as follows (see drawings for type of coating required): 1) Aluminum Coating shall meet the requirements of ASTM A491, Type I. 2) Metallic (Zinc) Coating shall meet the requirements of ASTM A392, Type II. 3) Polymer Coating shall meet the requirements of ASTM F 668, Class 2b over metallic coated steel wire. Color shall be black complying with ASTM F Selvage shall be knuckled at both selvages. A. Posts and Rails shall comply with the following: 4. ASTM F 1043 for framing and ASTM F 1083 for Group IC round pipe 5. Fence Height shall be as shown on the drawings and the Standard Details. 6. Strength Requirement shall be as required for light industrial according to ASTM F Horizontal Slide Gate Posts shall be Class 1 and shall meet the requirements of ASTM F Coating for Steel Framing shall be (as specified on the drawings): a. Metallic (Zinc) Coating shall meet the requirements of ASTM A392, Type II. b. Polymer Coating shall meet the requirements of ASTM F 668, Class 2b over metallic coated posts and rails. Color shall be black complying with ASTM F 934. American States Utility Services Chain Link Fences and Gates

3 2.3 TENSION WIRE A. Horizontal tension wire shall be provided at bottom of fence fabric. B. Horizontal tension wire shall be steel wire inch diameter, and shall be marcelled tension wire complying with ASTM A 817 and ASTM A 824 with a metallic coating Type III, Zn-5-Al-MM alloy. 2.4 SWING GATES A. Swing Gates shall comply with ASTM F 900 for single or double swing gate types (see drawings and Standard Details for gate type). B. Metal Pipe and Tubing shall be galvanized steel and shall comply with ASTM F 1083 and ASTM F 1043 for materials and protective coatings. C. Frames and Bracing shall be fabricated from round galvanized steel tubing with outside dimension and weight according to ASTM F 900 and the following: 1. Gate Fabric Height shall be 2-inches less than adjacent fence height. 2. Leaf width shall be as shown on the drawings. 3. Frame Members shall be tubular steel per the diameter shown on the Standard Details. 4. Bracing Members shall be tubular steel per the diameter shown on the Standard Details. 5. Frame Corners shall be constructed with assembled corner fittings and 1- inch diameter adjustable truss rods. D. Gate posts and frame end members shall be extended above top of chain link fabric at both ends of gate frame as indicated in the Standard Details to attach barbed wire assemblies. E. Hardware shall be provided as follows: 1. Latches shall be provided to permit operation from both sides of gate. 2. Hinges, center gate stops and keepers for each gate leaf shall be provided. 3. Latches shall be fabricated with integral eye openings for padlocking, and padlock shall be accessible from both sides of gate. 2.5 HORIZONTAL SLIDE GATES (if shown on the drawings) A. Slide Gates shall comply with ASTM F 1184 for single and double slide gate types (see drawings and Standard Details for gate type). American States Utility Services Chain Link Fences and Gates

4 B. Slide Gates shall be Type II Cantilever Slide Gates, Class 1 with external roller assemblies. C. Metal Pipe and Tubing shall be galvanized steel and shall comply with ASTM F 1184 for materials and protective coatings. D. Frames and Bracing shall be fabricated from members from round, galvanized steel tubing with outside dimension and weight according to ASTM F 1184 and the following: 1. Gate Fabric Height shall be as shown on the Standard Details. 2. Gate Opening Width shall be as shown on the drawings. 3. Frame Members shall be tubular steel per the diameter shown on the Standard Details. 4. Bracing Members shall be tubular steel per the diameter shown on the Standard Details. E. Frame Corners shall be constructed with assembled corner fittings and 1-inch diameter adjustable truss rods. F. Gate posts and frame end members shall be extended above top of chain link fabric at both ends of gate frame as indicated in the Standard Details to attach barbed wire assemblies. G. Roller Guards shall be provided as required per ASTM F 1184 for Type II, Class 1 gates. 2.6 FITTINGS A. Fittings shall comply with ASTM F 626. B. Fittings shall be coated to meet the same requirements as the other parts of the fence. 2.7 PRIVACY SLATS (if shown on the drawings) A. Privacy slats shall be provided as shown on the drawings. B. Privacy slats shall be UV light stabilized PVC. C. Privacy slats shall be the color designated on the drawings. 2.8 BARBED WIRE A. Barbed Wire shall be zinc coated steel and comply with ASTM A121; 2-point round barbs spaced not more than 4-inches on center. American States Utility Services Chain Link Fences and Gates

5 B. Barbed wire shall be installed on gates and fence as shown on the Standard Details. 2.9 GATE OPERATORS (if shown on the drawings) A. Factory assembled automatic gate operating system shall be provided and designed for gate size, type, weight, and operation frequency. Provide operation control system with characteristics suitable for Project conditions, with remote control stations, safety devices, and weatherproof enclosures. B. Gate operating system electrical requirements shall be coordinated with building electrical system. C. Gate operating system shall comply with NFPA 70. D. Gate operating system motor shall be sufficient to start, accelerate, and operate connected loads at designated speeds, within installed environment, with indicated operating sequence, and without exceeding nameplate rating or considering service factor; and shall comply with NEMA MG-1. Motor shall be voltage and phase as shown on the drawings. E. Gate Operators shall be mounted as shown on the plans. F. Remote Controls shall be separated from gate and motor and drive mechanism, with an NEMA 4X enclosure and with space for additional optional equipment. Provide station remote control device as shown on the drawings and of one of the types specified below: 1. Radio Control System shall be a digital system consisting of code compatible universal receiver with transmitter. 2. Telephone Entry System shall be a hands free voice communication system for connection to building telephone system with digital entry code activation of gate operator and auxiliary keypad entry if specified. 3. Key Card Access System shall be digital system activated by a key card device. The system shall be capable of being programmed for up to 100 key cards that can be activated or deactivated by the Utility. G. The following additional devices may be specified on the drawings: 1. Vehicle Detector system if required including automatic closing timer with adjustable time delay before closing designed to hold gate open until traffic clears. 2. Obstruction Detection Devices if required shall provide each motorized gate with automatic safety sensor(s). Activation of sensor(s) shall cause operator to immediately reverse gate in both opening and closing cycles and hold until clear of obstruction. American States Utility Services Chain Link Fences and Gates

6 3. Battery Backup System shall provide battery powered drive and access control system, independent of primary drive system CAST-IN-PLACE CONCRETE A. See Section Miscellaneous Cast-in-Place Concrete FENCE GROUNDING A. Grounding of the fence shall be provided and shall comply with the following: SECTION 3 EXECUTION 3.1 INSTALLATION 1. Conductors shall be bare, solid wire for No. 6 AWG and smaller; stranded wire for No. 4 AWG and larger. 2. Wire material above and below grade shall be copper. 3. Bonding Jumpers shall be braided copper tape, 1 inch wide, woven of No. 30 AWG bare copper wire, terminated with copper ferrules. 4. Connectors and Grounding Rods shall comply with UL 467. A. Chain link fencing shall comply with ASTM F 567 and more stringent requirements specified. B. Post excavation shall be completed by drilling or hand excavating holes for posts to diameters and spacings indicated, and shall be in firm, undisturbed soil. C. Post shall be set in concrete at indicated spacing into firm, undisturbed soil. D. Concrete shall be placed around posts to dimensions indicated and vibrated or tamped for consolidation. The aboveground portion of posts shall be protected from concrete splatter. E. Terminal Posts shall be located at the terminal end, corner, and all gate posts per ASTM F 567 and terminal pull posts shall be located at changes in horizontal or vertical alignment. F. Line Posts shall be space line posts uniformly per drawings and Standard Details. G. Post Bracing and Intermediate Rails shall be installed in conformance with ASTM F 567. Braces shall be installed at end and gate posts and at both sides of corner and pull posts. H. Tension Wire shall be installed in conformance with ASTM F 567, and shall maintain plumb position and alignment of fencing. American States Utility Services Chain Link Fences and Gates

7 I. Top Rails and Center Rails shall be installed in conformance with ASTM F 567. J. Chain Link Fabric shall be installed outside of the enclosing framework. See Standard Details for spacing between finish grade and surface and bottom selvage. K. Tie Wires shall be attached in conformance with ASTM F 626. Ends of wire shall be bent to minimize hazard to individuals and clothing. L. Carriage bolts and nuts for tension bands shall be installed on the opposite side of the fence to the fence fabric. M. Privacy slats shall be installed on a diagonal in direction indicated on the drawings, and securely locked in place. N. Barbed wire shall be uniformly spaced and angled toward security side of fence as indicated on drawings. Barbed wire shall be pulled taut, shall be installed securely to extension arms, and shall be secured to end post or terminal arms. 3.2 GATE INSTALLATION A. Gates shall be installed in accordance with the manufacturer's written instructions, and shall be level, plumb, and secure for full opening without interference. B. Ground set items shall be installed in concrete for anchorage. C. Fabric shall be attached the same method as the fencing is attached to the posts. D. Hardware shall be attached using tamper resistant or concealed means, shall be adjusted for smooth operation, and shall be lubricated where necessary. 3.3 GATE OPERATOR INSTALLATION A. Gate operators shall be installed in accordance with the manufacturer's written instructions, aligned and true to fence line and grade. B. Cast-in-place or precast concrete bases/pads shall be constructed as shown on the drawings and/or required by the manufacturer. Concrete shall be reinforced in accordance with the manufacturer's written instructions and/or as indicated on drawings. C. Vehicle Loop Detector System shall be installed by cutting grooves in pavement and burying and seal wire loop in accordance with the manufacturer's written instructions. Equipment operated by detector shall be connected to the detector in accordance with the manufacturer's written instructions. D. Gate operators shall comply with NFPA 70 and manufacturer's written instructions for grounding of electric powered motors, controls, and other devices. American States Utility Services Chain Link Fences and Gates

8 3.4 GROUNDING AND BONDING A. Fence Grounding shall be installed at maximum intervals of 1000 feet. B. Grounding shall be achieved by driving a grounding rod vertically until the top is 6-inches below finished grade at each grounding location. The ground rod shall be connected to the fence with No. 6 AWG conductor. The conductor shall be connected to each fence component at the grounding location. C. Bonding jumper shall be connected between gate post and gate frame. D. All connections shall be made to minimize the possibility of galvanic action or electrolysis. E. If fence terminates at lightning protected building or structure, the fence shall be grounded and the fence grounding conductor shall be bonded to the lightning protection down conductor or the lightning protection grounding conductor, and be in conformance with NFPA FIELD QUALITY CONTROL. A. Grounding Resistance Testing shall be performed by a qualified independent testing agency at the Contractor s expense for field quality control testing. END OF SECTION American States Utility Services Chain Link Fences and Gates

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN-LINK FENCES AND GATES 02821/1 SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where

More information

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College SECTION 323113 - CHAIN LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

1. Fence and gate posts, rails, and fittings. 2. Chain-link fabric, reinforcements, and attachments.

1. Fence and gate posts, rails, and fittings. 2. Chain-link fabric, reinforcements, and attachments. SECTION 323113 - CHAIN LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION CHAIN LINK FENCING

SECTION CHAIN LINK FENCING SECTION 02835 - CHAIN LINK FENCING 1.0 GENERAL 1.1 Furnish and install chain link fencing complete in place with gates and accessories as specified herein and as shown on the Contract Drawings. 1.2 Reference

More information

Bus Facility

Bus Facility SECTION 32 31 13.53 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes furnishing and installing chain-link fabric fence, gate, and appurtenances. 1.02

More information

SECTION HIGH-SECURITY CHAIN LINK FENCES AND GATES

SECTION HIGH-SECURITY CHAIN LINK FENCES AND GATES SECTION 323113.53 - PART 1 - GENERAL 1.1 SUMMARY A. Section includes high-security chain-link fences and motor-operated, horizontal slide gates. 1.2 PERFORMANCE REQUIREMENTS A. Delegated Design: Design

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT SPECIFICATION EO-1124 REVISION 3 November 2013 EFFECTIVE DATE November 11,

More information

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES SECTION 32 31 13 CHAIN LINK FENCES AND GATES SPEC WRITER NOTE: 1. Delete text between // // not applicable to project. Edit remaining text to suit project. 2. Use this section in specifying permanent chain

More information

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017 SECTION 02821 - CHAIN-LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

LS3P ASSOCIATES LTD. FCCC CHASSIS SHIPPING FACILITY

LS3P ASSOCIATES LTD. FCCC CHASSIS SHIPPING FACILITY SECTION 323113 - CHAIN LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION CHAIN LINK FENCES

SECTION CHAIN LINK FENCES SECTION 02 44 40 PART 1 - GENERAL 1.1 DESCRIPTION A. Work included: Provide chain link fence system where shown on the Drawings, as specified herein, and as needed for a complete and proper installation.

More information

MO: Tl RSA: 1406B

MO: Tl RSA: 1406B MO: Tl425-02 SECTION 323113- CHAIN LINK FENCES AND GATES PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

ITEM 555 CHAIN LINK FENCING

ITEM 555 CHAIN LINK FENCING ITEM 555 AFTER MARCH 1, 2012 CHAIN LINK FENCING 555.1 Description. This item shall govern for furnishing the quantities of chain link fencing and gates as shown on the plans, including all posts, bracing

More information

SECTION CHAIN LINK FENCES AND GATES (PARK)

SECTION CHAIN LINK FENCES AND GATES (PARK) SECTION 02821 CHAIN LINK FENCES AND GATES (PARK) PART I GENERAL 1.1 SECTION INCLUDES A. Installation of chain link fences, and gate units provided by single source including erection accessories, fittings,

More information

Colorado River Aqueduct Pumping Plants 230 kv Disconnect Switches Replacement

Colorado River Aqueduct Pumping Plants 230 kv Disconnect Switches Replacement DATE: July 15, 2011 ADDENDUM NUMBER: 2 MODIFYING: Specifications No. 1698 PROJECT: Colorado River Aqueduct Pumping Plants 230 kv Disconnect Switches Replacement BID TIME AND DATE: 2:00 p.m., July 19, 2011

More information

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,

More information

LOCATION MAP Salzedo Street, Third Floor Coral Gables, FL (305)

LOCATION MAP Salzedo Street, Third Floor Coral Gables, FL (305) 3081 Salzedo Street, Third Floor Garage Floor Plan - Level 1 Garage Exterior Elevations -PERMIT SET LOCATION MAP PROJECT LOCATION Proj. Drawn MG.17071.00 Project Manager: PM Designer: Reviewed Approved

More information

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories. SECTION 02830 CHAIN LINK FENCES AND GATES (GALVANIZED) 1.0 GENERAL 1.1 Section Includes A. Fence framework, fabric, gates, and accessories. B. Excavation for post bases; concrete footing for posts. C.

More information

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION

ANTI RAM SECURITY CHAIN LINK FENCE - 4, MPH SECTION ANTI RAM SECURITY CHAIN LINK FENCE - 4,000 LB @ 20 MPH SECTION 32 31 13.53 2015

More information

Copyright 2002 and 2005 AIA MASTERSPEC Full Length 08/02 (R 02/06)

Copyright 2002 and 2005 AIA MASTERSPEC Full Length 08/02 (R 02/06) SECTION 323113 - CHAIN LINK FENCES AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES SECTION 32 31 13 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.1 SUMMARY A. This Section includes materials applicable for commercial/industrial and security vinyl coated chain link fence and framework.

More information

A. ASTM A121 Specification for Metallic-Coated Carbon Steel Barbed Wire. B. ASTM A392 Specification for Zinc-Coated Steel Chain-Link Fence Fabric

A. ASTM A121 Specification for Metallic-Coated Carbon Steel Barbed Wire. B. ASTM A392 Specification for Zinc-Coated Steel Chain-Link Fence Fabric SECTION 32 31 13 CHAIN LINK FENCE AND GATES 2015 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements, general and supplemental

More information

TITLE: CAMP JOHNSON OVERPASS / HWY 17 BYPASS SECURITY FENCE UPGRADES

TITLE: CAMP JOHNSON OVERPASS / HWY 17 BYPASS SECURITY FENCE UPGRADES CONTRACT # N40085-15B-0457 PROJECT # 15R036CN MACC # 15-0457 MAXIMO# 4608934 TITLE: CAMP JOHNSON OVERPASS / HWY 17 BYPASS SECURITY FENCE UPGRADES ATTACHMENTS: 1. 15-0457 CJ OVERPASS SECURITY UPGRADES Site

More information

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES SECTION 2831 ITEM F-162 CHAIN-LINK FENCES PART 1 - GENERAL 1.1 DESCRIPTION. This item shall consist of furnishing and erecting a chain-link fence in accordance with these specifications and the details

More information

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES SECTION 32 31 13 SPEC WRITER NOTES: Use this section only for NCA projects. Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section

More information

CHAIN LINK FENCES AND GATES

CHAIN LINK FENCES AND GATES SECTION 02831 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.01 SUMMARY A. Alternate Material for Fence Post and Framing Material: Where schedule 40 galvanized steel is specified, the following will be accepted:

More information

SECTION CHAIN LINK FENCING

SECTION CHAIN LINK FENCING Section 02444 1 SECTION 02444 CHAIN LINK FENCING PART 1 - GENERAL 1.01 DESCRIPTION A. Requirement. Under these specifications, the Contractor shall furnish all materials, labor, tools, and equipment required

More information

A NEW PRE-K BUILDING FOR BIG SPRING LAKE KINDERGARTEN SCHOOL FOR THE ALBERTVILLE CITY BOARD OF EDUCATION ALBERTVILLE, ALABAMA

A NEW PRE-K BUILDING FOR BIG SPRING LAKE KINDERGARTEN SCHOOL FOR THE ALBERTVILLE CITY BOARD OF EDUCATION ALBERTVILLE, ALABAMA McKee and Associates Architecture and Interior Design Addendum No. FOUR Date: 09.24.18 Project: A NEW PRE-K BUILDING FOR BIG SPRING LAKE KINDERGARTEN SCHOOL FOR THE ALBERTVILLE CITY BOARD OF EDUCATION

More information

SECTION CHAIN LINK FENCES AND GATES

SECTION CHAIN LINK FENCES AND GATES SECTION 02831 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.01 REFERENCES AND CODES A. Florida Department of Education, Office of Educational Facilities - State Requirements for Educational Facilities -

More information

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS DOCUMENT 00085B ADDENDUM ADDENDUM NO. 1

CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS DOCUMENT 00085B ADDENDUM ADDENDUM NO. 1 ADDENDUM Date of Addendum: December 30 th, 2015 PROJECT NAME: Fencing for Sportspark PROJECT NO: GO1507 BID DATE: Tuesday, January 5 th, 2016 FROM: City of Friendswood Department of Public Works 1306 Deepwood

More information

TWINBAR FENCE SYSTEM ENTER PROJECT NAME HERE 12/2011

TWINBAR FENCE SYSTEM ENTER PROJECT NAME HERE 12/2011 SECTION 32 31 17 ORNAMENTAL WELDED WIRE FENCE AND GATES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

CHAIN LINK FENCES AND GATES

CHAIN LINK FENCES AND GATES SECTION 02831 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.01 REFERENCES AND CODES A. Florida Department of Education, Office of Educational Facilities - State Requirements for Educational Facilities -

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-32 31 26 (April 2008) -------------------------- Preparing Activity: USACE Superseding UFGS 32 31 26 (January 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

SECTION ORNAMENTAL WELDED STEEL FENCING

SECTION ORNAMENTAL WELDED STEEL FENCING SECTION 032300 ORNAMENTAL WELDED STEEL FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION ORNAMENTAL ALUMINUM FENCING SECTION 032300 ORNAMENTAL ALUMINUM FENCING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS

CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS January 2014 SPECIFICATION CW 3550 R3 CW 3550 Chain Link and Drift Control Fence TABLE OF CONTENTS 1. GENERAL CONDITIONS... 1 3. DESCRIPTION... 1 5. MATERIALS... 1 5.1 Drift Control Fence... 1 5.1.1 Approved

More information

SECTION 1208 CHAIN LINK FENCING DESCRIPTION

SECTION 1208 CHAIN LINK FENCING DESCRIPTION SECTION 1208 CHAIN LINK FENCING 1208-1 DESCRIPTION This item covers the requirements for furnishing materials and constructing new chain link fences and gates in accordance with the details included herein

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information

F-SERIES: FF XT SPECIFICATIONS Exterior Swinging Four-Fold Door Systems

F-SERIES: FF XT SPECIFICATIONS Exterior Swinging Four-Fold Door Systems Version 5.22.13 F-SERIES: FF100-600XT SPECIFICATIONS Exterior Swinging Four-Fold Door Systems OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT. CONSULT MANUFACTURER

More information

Fence SpecCheck. A53/A53M-12 Schedule 40 & Schedule 80 Pipe: Specification for Pipe, Steel, Black

Fence SpecCheck. A53/A53M-12 Schedule 40 & Schedule 80 Pipe: Specification for Pipe, Steel, Black Fence SpecCheck ASTM Specifications (December 2017) www.astm.org A53/A53M-12 Schedule 40 & Schedule 80 Pipe: Specification for Pipe, Steel, Black and Hot-Dipped, Zinc Coated, Welded and Seamless Schedule

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 GROUNDING AND BONDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION CHAIN LINK FENCING

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION CHAIN LINK FENCING PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Requirements vary. A/E shall consult with DPS project manager to determine extent and type of permanent site fencing to be employed. B. Provide

More information

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE ONTARIO PROVINCIAL STANDARD SPECIFICATION OPSS.PROV 772 NOVEMBER 2017 (Formerly OPSS 772, November 2012) Note: The PROV published in November 2017 replaces OPSS 772 COMMON, November 2012 with no technical

More information

Special Provision No. 541S01 October OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced with the following:

Special Provision No. 541S01 October OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced with the following: CHAIN LINK FENCE - Item No. GATES - Item No. Special Provision No. 541S01 October 1998 AMENDMENT TO OPSS 541, DECEMBER 1990 OPSS 541, Construction Specifications for Chain Link Fence, is deleted and replaced

More information

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 323100 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007 Sheet 1 of 7 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007 Delete SECTION 828 and replace with the following: SECTION 828 FENCING 828.1 DESCRIPTION

More information

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE

CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 541 DECEMBER 1990 CONSTRUCTION SPECIFICATION FOR CHAIN LINK FENCE 541.01 SCOPE 541.02 REFERENCES 541.03 DEFINITIONS 541.05 MATERIALS TABLE OF CONTENTS

More information

Bear Exhibit Fence Upgrades. The following modifications are hereby made part of the contract documents:

Bear Exhibit Fence Upgrades. The following modifications are hereby made part of the contract documents: ADDENDUM TO BID T2017-04 Metropolitan Park District Department of Planning, Design and Development 4702 South 19 th Street Tacoma WA 98405 Date Prepared: November 17, 2017 Bid Number: T2017-04 Addendum

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Doors B. Track and Framing 1.2 RELATED SECTIONS A. Section 04810 - Unit Masonry Assemblies: Prepared opening in masonry.

More information

FF200, FOUR-FOLD DOORS CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

FF200, FOUR-FOLD DOORS CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS. FF200, FOUR-FOLD DOORS CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? SECTION 08360 SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Glazed Aluminum

More information

SECTION ACCORDION FOLDING PARTITIONS

SECTION ACCORDION FOLDING PARTITIONS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Advisory Circular PAGECONTROLCHART. Remove Pages Dated II Inscr t Pages Dated l/2/ thru 258-l 7/6/ l/2/90

Advisory Circular PAGECONTROLCHART. Remove Pages Dated II Inscr t Pages Dated l/2/ thru 258-l 7/6/ l/2/90 U.S. Department of Transportation Federal Aviation Administration Advisory Circular Subject: Change 8 to STANDARDS FOR SPECIFYING CONSTRUCTION OF AIRPORTS Date: 7/6/94 AC No: 150/53701OA Initiated by:

More information

SECTION 1043 FENCE MATERIAL

SECTION 1043 FENCE MATERIAL SECTION 1043 FENCE MATERIAL 1043.1 Scope. This specification covers the material required in the construction of chainlink fence and woven wire fence. 1043.2 Basis of Acceptance. The basis of acceptance

More information

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System Version 5.22.13 N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER

More information

1. Include plans, elevations, sections, details, and attachments to other work.

1. Include plans, elevations, sections, details, and attachments to other work. SECTION 102213- PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1 Prepared by: Digicon Information Inc. Page 1 This section includes overhead type Parking Security Gates, as manufactured by Westgate Entrematic, a division of Helton Group of Companies. DISCLAIMER: This

More information

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 541 NOVEMBER 2005 CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE TABLE OF CONTENTS 541.01 SCOPE 541.02 REFERENCES 541.03 DEFINITIONS 541.04 SUBMISSION

More information

Automated Cantilevered Aluminum Sliding Gate

Automated Cantilevered Aluminum Sliding Gate Town of Derry, New Hampshire REQUEST FOR PROPOSALS B18-128 January 25, 2018 The Town of Derry - Department of Public Works is seeking proposals for: Automated Cantilevered Aluminum Sliding Gate Introduction

More information

F-SERIES: F SPECIFICATIONS Four-Fold Door Systems

F-SERIES: F SPECIFICATIONS Four-Fold Door Systems Version 5.22.13 F-SERIES: F100-600 SPECIFICATIONS Four-Fold Door Systems OPTIONS ARE IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT. CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

More information

SECTION 410 FENCES All materials shall be new and without flaws or defects of any type GENERAL

SECTION 410 FENCES All materials shall be new and without flaws or defects of any type GENERAL SECTION 410 FENCES 410.1 GENERAL This work shall consist of the construction of fences and gates in substantial compliance with the specifications, lines, and grades shown on the plans or established by

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED SECTION 08350 ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

LTH3700, HOLLOW METAL SLIDING FIRE DOOR

LTH3700, HOLLOW METAL SLIDING FIRE DOOR LTH3700, HOLLOW METAL SLIDING FIRE DOOR Consult Manufacturer for additional options or modifications PART 1-GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 12 2113 - LOUVER BLINDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

PROPOSAL FOR WROUGHT IRON PERIMETER FENCE WITH GATE TO CITY OF POMONA

PROPOSAL FOR WROUGHT IRON PERIMETER FENCE WITH GATE TO CITY OF POMONA PROPOSAL FOR WROUGHT IRON PERIMETER FENCE WITH GATE TO CITY OF POMONA The undersigned hereby proposes and agrees to perform all the work and improvements therein described, and to furnish all labor, materials,

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System Version 5.22.13 N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITONAL

More information

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on

More information

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS SECTION 26 05 26 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 [08 33 13] COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Metal Counter

More information

REQUEST FOR BIDS Public Works Contract SPECIFICATIONS FOR FENCE REPAIRS AND REPLACEMENT

REQUEST FOR BIDS Public Works Contract SPECIFICATIONS FOR FENCE REPAIRS AND REPLACEMENT REQUEST FOR BIDS Public Works Contract SPECIFICATIONS FOR FENCE REPAIRS AND REPLACEMENT DATE OF RELEASE: DATE OF CLOSING: RFB ID: July 18, 2013 at 8:00 am (cst) August 5, 2013 at 4:30 pm (cst) 0718201301

More information

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System Version 5.22.13 L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System OPTIONS ARE LISTED IN BOLD, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER

More information

SECTION DECORATIVE METAL RAILINGS

SECTION DECORATIVE METAL RAILINGS SECTION 05 73 00 DECORATIVE METAL RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Vertical Stainless Steel Cable Railing System. B. Horizontal Stainless Steel Cable Railing System. 1.2 RELATED SECTIONS

More information

ARCHITECTURAL DESIGN SPECIFICATIONS SG-4 - CRASH RATED SWING GATE

ARCHITECTURAL DESIGN SPECIFICATIONS SG-4 - CRASH RATED SWING GATE ARCHITECTURAL DESIGN SPECIFICATIONS SG-4 - CRASH RATED SWING GATE PART I General 1.1 SECTION INCLUDES A. This section covers the furnishing and installation of a SG-4 Crash Rated Swing Gate Vehicle Barrier

More information

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE

CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 772 NOVEMBER 2010 CONSTRUCTION SPECIFICATION FOR CHAIN-LINK FENCE TABLE OF CONTENTS 772.01 SCOPE 772.02 REFERENCES 772.03 DEFINITIONS 772.04 DESIGN

More information

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on

More information

Series - 1

Series - 1 SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

SECTION PART 1 GENERAL

SECTION PART 1 GENERAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Grounding of electrical systems and equipment and basic requirements for ground for equipment, circuits, and systems.

More information

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on

More information

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS SECTION 08 36 00 SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on

More information

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE

SECTION SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE SECTION 08 33 00 SECURITY GRILLES 670 SERIES UPCOILING SECURITY GRILLE Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round

More information

A. The work consists of furnishing a Chiller Noise Reduction System as listed in the specifications.

A. The work consists of furnishing a Chiller Noise Reduction System as listed in the specifications. SECTION 32 31 14 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply

More information

SECTION FACILITY LIGHTNING PROTECTION

SECTION FACILITY LIGHTNING PROTECTION PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 41 00 FACILITY LIGHTNING PROTECTION SPEC WRITER NOTE: Delete between //----//if not applicable to project. Also delete any other item or paragraph not applicable

More information

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows as

More information

MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS

MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1541 NOVEMBER 2005 (Reissued November 2010) MATERIAL SPECIFICATION FOR CHAIN-LINK FENCE COMPONENTS TABLE OF CONTENTS 1541.01 SCOPE 1541.02 REFERENCES

More information

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 DESCRIPTION SECTION 28 05 26 GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY SPEC WRITER NOTE: Delete // // if not applicable to project. Also delete any other item or paragraph

More information

SECTION METAL ATHLETIC LOCKERS

SECTION METAL ATHLETIC LOCKERS SECTION 10 51 13 - METAL ATHLETIC LOCKERS PART 1 GENERAL 1.1 SECTION INCLUDES A. DESCRIPTION: Furnish and install factory-assembled Heavy-Duty MIG-Welded Metal Lockers, complete, as shown and specified

More information

A. Coordinate chain link fence & gate work with work before and after. See especially: 1. Bollards on worksite that are more than 10 ft from fence.

A. Coordinate chain link fence & gate work with work before and after. See especially: 1. Bollards on worksite that are more than 10 ft from fence. 02830 CHAIN LINK FENCES AND GATES ************************************************************************************************************ Specifier: This section replaces 02831 (2004). It reflects

More information

ITCC provides products to comply entirely with international standards specifications; applicable standards are ASTM, BSI, & SSD.

ITCC provides products to comply entirely with international standards specifications; applicable standards are ASTM, BSI, & SSD. FENCE FENCES Chain Link Fencing remains the favorite for residential and industrial needs, as it is still up to today one of the easiest and most cost effective ways to provide security and access control

More information

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Insulated Steel Doors B. Commercial Steel Doors C. Aluminum Doors D. Track and Framing E. Hardware 1.2 RELATED SECTIONS A.

More information

TRANSPORT LINK CHAIN LINK CANTILEVER GATES

TRANSPORT LINK CHAIN LINK CANTILEVER GATES TRANSPORT II TRANSPORT ESTATE TRANSPORT IS ADAPTRACK CHAIN LINK CANTILEVER GATES 2"sq x.25" UPRIGHTS & DIAGONAL BRACES GATE TRACKS PRE-DRILLED FOR LEFT OR RIGHT OPENINGS ***GATE FABRIC MESH & BARBED WIRE

More information

OPTIONS ARE LISTED IN RED, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

OPTIONS ARE LISTED IN RED, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS. Version 5.29.12 FF700, HURRICANE RATED FOUR-FOLD DOOR SPECIFICATIONS OPTIONS ARE LISTED IN RED, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR

More information

Metropolitan Parks of Tacoma Addendum #01 Waterfront Phase 1 GC/CM Guy F. Atkinson Construction Page 1 of 1

Metropolitan Parks of Tacoma Addendum #01 Waterfront Phase 1 GC/CM Guy F. Atkinson Construction Page 1 of 1 Metropolitan Parks of Tacoma Addendum #01 Waterfront Phase 1 GC/CM Guy F. Atkinson Construction Page 1 of 1 Sub Package WP01-05: Addendum 01 Release Date: 04/15/16 Receipt of this Addendum #01 must be

More information

SECTION LIGHTNING PROTECTION SYSTEM