1 VIII. BUILDING DEPARTMENT SCHEDULE & CHECKLIST OF INSPECTIONS
2 BUILDING INSPECTIONS (719) Inspectors are available to answer questions from 7:30 a.m. to 8:30 a.m. Monday through Friday Conference at any other time will need to be scheduled with the individual inspector. Inspections are done on a first come, first served basis. Cut off time for Inspections is 3:00 p.m. the previous business day. We do have a 24-hour voic system, which enables you to call in your inspection after hours. We cannot guarantee a morning or afternoon inspection. Our inspectors set their own schedules and must take the most expeditious route. If the property is behind a locked gate, please provide a key or gate combination. If the property cannot be accessed by the inspector a $42.00 reinspection fee will be charged. Keys can be securely kept at the Building Department and can be picked up after final inspections have been passed. INSPECTIONS THAT ARE CANCELLED AFTER 9:00 A.M. WILL REQUIRE A REINSPECTION FEE OF $42.00 Only the contractors listed as performing the work can call for those inspections. Any change in contractors must be provided to the Building Department as soon as possible. If an inspection is called in for and there is a discrepancy with the contractor of record, the inspection will not be scheduled. PLEASE NOTE: The following inspections are not included in a standard residential or commercial permit and will require an additional $42.00 each: Additional Partial Pre-Frame Pre-Final The structure cannot be occupied before the final inspections have been passed and the Certificate of Occupancy has been issued.
3 CHECK LIST OF INSPECTIONS Health Building PLUMBING Pre-Site Footing Base Septic System Final Foundation Top Out & Supply Frame Final Final Mechanical Electrical Other Vents Temporary Log Moisture Gas piping Inside & Outside Rough Wood Stove/Fireplace Heat Final Permanent Service Solar Final Driveway Final Well if applicable SEQUENCE OF INSPECTIONS FOR GENERAL RESIDENTIAL CONSTRUCTION 1. Building Footing Electrical Temporary (if applicable) 2. Building Foundation 3. Plumbing Base 4. Plumbing Top Out & Supply Electrical - Rough Frame Mechanical Vent, Gas piping, Woodstove Deck Piers 5. Electrical Final Must be passed before any other finals can be inspected. 6. Heat Final Plumbing Final Building Final The structure cannot be occupied before the final inspections have been completed and the Certificate of Occupancy has been issued. Applicable to City of Woodland Park: City Water and Sewer Utility Connection Contact City Public Work Department at (719) or (719) Applicable to City of County: Aquila Natural Gas: Customer Service Intermountain Rural Electric: (719) for application
4 FOOTING AND FOUNDATION CHECKLIST This checklist is intended as a guide only. All references are to the 1997 Uniform Building Code unless otherwise noted. ADDRESS NUMBER TO BE POSTED PLAINLY AT THE ROAD PRIOR TO FIRST INSPECTION. THE FOUNDATION ENGINEERING MUST BE ON THE JOB SITE FOR THESE INSPECTIONS. APPROVED SET OF PLANS AND PERMIT ON JOB SITE THRU FINAL INSPECTIONS. Footing Inspection: 1. Property corners and property lines must be marked with states that are taller than the Vegetation and snow. 2. Portable toilet must be on the construction site unless bathrooms are immediately available On the construction site. 3. Layout of forms as per plans. 4. Check plans for steel requirements. 5. Sec Check reinforcing steel (overlaps, size, grade, location) as per design. 6. Check frost depth (30 minimum), soil at bottom firm (no snow, mud, etc.) 7. Table 18-I-C 8 X 16 minimum size in non-engineered foundation. Foundation Concrete: 1. Check location, height, frost depth, thickness, and steel requirements as per design. 2. Check reinforcing steel (size, grad, location, overlaps) as per design. 3. Anchor bolts (1/2 X10 ) 1 from end of plate, 6 maximum distance between or per Engineering. 4. Sill of redwood or pressure treated wood, if installed minimum thickness. 6. Beam pockets (if required). Block Before Pouring: Pier: 1. Check location, height and thickness. 2. Check vertical and horizontal reinforcing (size, grade, spacing) as per design. 3. Sills of redwood or pressure treated wood. 4. Check anchor bolts. 1. Check Location, size, depth. 2. No Debris in sono-tubes or forms. 3. Minimum 30 frost penetration. 4. Reinforcement as per design.
5 FRAME CHECK LIST Residential only This checklist is intended as a guide only. All references are to the 1997 Uniform Building Code unless otherwise noted 1. Sec Attic ventilation 2. Sec Exit Requirements, exit door size( one exit door 3 X 6 8 ). 3. Sec. 509 & (See Section for Commercial), Residential as follows: Rise 8 maximum Run 9 minimum Headroom 6 8 minimum Width 36 minimum Handrails required with 4 or more risers Height 34 to 38 above nosing of treads including carpet Guardrail required over 30 above grade height 30 minimum including carpet Intermediate railings 4 spacing maximum 4. Sec 2320 Floor system span and grade of joists, joist hangers, bridging, blocking and spacing. 5. Sec & Fastening and type of foundation plates and sills. 6. Sec Installation of sub-flooring 7. Sec Header mailed into studs, check for size, spacing, bearing, alignment and nailing of exterior and interior wall studs, headers, trimmers, and cripples. 8. Table 23-IV-B Size, height, and spacing of wood studs. 9. Sec Corner wind bracing of walls, 4 X 8 plywood sheets or cut-in 1 X 4 45 to 60 degrees. 10. Sec Three studs at corner of exterior wall. 11. Sec Weather resistive barrier on all exposed surfaces. 12. Sec Egress windows from bedrooms and basement Sill 44 maximum height from floor Open window area 5.7 sq. ft. minimum (821 sq. in.) Open height 24 minimum Open width 20 minimum 13. Sec Smoke alarm installation. 14. Sec & 11 Straps and nailing where joists, studs, and plates notched. 15. Sec Ceiling height; habitable space 7 6 ; kitchen, hall, bathroom Sec Attic access 22 X Sec Truss and rafter ties. 18. Sec Ventilation. 19. Sec Crawl space access, 18 X Sec and Chapter 31 Wood stove installation, fire stops, chimney height. 21. Sec Plates, sills, and sleepers of treated wood or foundation redwood. 22. Sec Maximum distance of untreated wood to exposed ground: Joists- 18 Girders 12 Siding Sec Foundation ventilation, 1 sq ft. for each 150 sq. ft of area. 24. Sec One-hour occupancy separation between residence and garage. 25. Sec Headers, two pieces of 2 inch framing lumber mounted vertically, supported by two (2) trimmers, over openings in bearing walls, or any opening over Sec Vertical solid blocking on top plate between roof trusses.
6 PLUMBING CHECK LIST This checklist is intended as a guide only. All references are to the 1997 Uniform Plumbing Code Unless otherwise noted. Base: 1. Sec (Building) Proper material to 2 feet outside building. 2. Sec ¼ per footfall. 3. Sec Firm bed support. 4. Sec Directional flow fitting. 5. Table 7-3 Minimum trap size. a) 2 floor drain b) 2 shower c) 1 ½ tub 6. Sec Horizontal vents. 7. Sec Inspection Test 10 feet - water 5 lbs. - air 8. Table 7-5 Proper sizing for total load. 9. Sec Cement joints not allowed on ABS to PVC. Top Out and Supply: Waste and Vents 1. Sec 701 Proper material 2. Table 7-3 Proper sizing (D F U ) 3. Sec 314 Support properly. 4. Chapter 9 and Table 7-5 correct venting. 5. Sec. 707 Clean outs. 6. Table 7-3 Minimum size of traps and trap arms. 7. Sec Inspection Test 8. Sec Joints and connections Water Pipe: 1. Table 6-4 and 6-5 Proper size. 2. Sec. 314 Supported properly. 3. Sec. 604 Approved material. Final: 1. Sec. 401 and Table 14-1 Approved fixtures. 2. Chapter 10, Sec Air gaps. 3. Sec All fixtures trapped. 4. Hot and cold water to appliances and fixtures. 5. Sec and Temperature and pressure on hot water heater.
7 GAS PIPING CHECK LIST This checklist is intended as a guide only. All references are to the 1997 Uniform Plumbing / Mechanical Code. Unless otherwise noted. 1. Check demand (total BTU/hr.) for each appliance. 2. Check type of gas. 3. Sec Minimum pipe size. 4. Sec trench. 5. Sec Tracer wire. 6. Sec Metal risers. 7. Sec No piping on ground under building. 8. Table 12-2 Pipe supports. 9. Sec PSI/15 min.; Welded pipe 60 PSI/30 min. 10. Table 12-3 & 12-4, Sec , Sec Length and size of connector. 11. Sec Location of approved shut offs for appliances. 12. Sec Type of fittings for concealed locations. 13. Sec Location of outside building shut-off. 14. LP Detector and Solenoid shut off for LP appliances below the first floor.
8 FINAL CHECK LIST This Checklist is intended as a guide only. All references are to the 1997 Uniform Building Code Unless otherwise noted. Minimum Requirements to Obtain a Certificate of Occupancy 1. At least one (1) complete, working bathroom. This is to include a toilet, lavatory, a bathtub or tub/shower combination). 2. A door on the bathroom. 3. All electrical fixtures installed or covered by a blank plate. 4. Hot and cold running water. 5. Kitchen sink installed, sealed and functioning. 6. Functioning heat system. 7. All safety features in place (guardrails/handrails, smoke detectors, etc.). 8. Permanent Address numbers ( 5 tall with ½ stroke, visible from the road from both directions). 9. Final inspection passed on Driveway permit and driveway accessible. 10. Final inspection passed on Septic permit and system functioning. 11. Final Grading completed (sloping away from foundation, etc.) Note: Paint, interior trim and floor coverings (as long as stair heights, etc. can be determined) are not required to be completed to obtain a Certificate of Occupancy.
9 ELECTRICAL CHECKLIST This checklist is intended as a guide only. All references are to the 2003 National Electric Code; all prerequisites of the Company supplying power shall apply. A directive guideline for the installation of temporary or permanent service equipment is available at Intermountain Rural Electric Association or Aquila. A. Temporary Service: 1. The minimum size of a temporary service shall be 60 Amperes per Article (D). All other services shall be not less than 60 Amperes. 2. The Temporary Service must include a120 volt receptacle controlled by a ground fault circuit interrupter. 3. All other outlets in a temporary service must be wired with the proper size wire, over-current protection, and must be G.F.I. protected for personnel per Article (A). 4. All components of a temporary service shall be housed in rainproof or NEMA 3R enclosure. B. Load Calculations: Load Calculations Required only if residence is to be heated electrically (i.e. electric baseboard heat, electric forced air furnace, electric boiler, fixed electric heating panels). Use: III Optional calculations for computing feeder and service loads optional calculation Dwelling unit, plus: fixed electric space heating. Doing these calculations will assure that the correctly sized service, and service feeders are installed at this time, future provisions should be addressed if additional power is to be required (i.e. outbuildings, barn, detached garages to be fed from the main dwelling service). C. Permanent Service: 1, The smallest size permanent service allowed is 100 Amperes Article Wire size shall be calculated based on Article (B) (6) conductor types and sizes for 120/240 volt, single phase, 3 wire dwelling services and feeders. 3. Permanent Service for overhead to underground applications must be mounted securely to an REA meter pole. 4. Second Services on an existing meter pole allowed only if the following conditions are met: a) Proper utility easement has been obtained and recorded. b) Service is stood away from the pole a minimum of 4 inches at a 90-degree angle to existing service. c) Pole is bucket accessible. d) With Special Permission from I.R.E.A. (Intermountain Rural Electric Assoc.) 5. If the Service is mounted to the dwelling and the service mast protrudes through the soffit and roof, then the service riser shall be of 2 inch rigid, (GRC) conduit regardless of size, 100 or 200 Amperes. Point of attachment know must be 12 inches below weather head.
10 A minimum of 36 inches of feeder conductor to extend from the weather head with the grounded conductor clearly marked with a continuous yellow line, or a minimum of 6 inches of white phase, or marking tape. 6. If the Service drop has adequate ground clearance and it does not penetrate the soffit or roof, then Thinwall (EMT) electro-metallic tubing is allowed. REA furnishes the eyebolt, which must penetrate through a framing member in the exterior wall, adjacent to the weather head. All other conditions above apply. 7. Required clearances from the ground are as follows: Minimum of 12 feet from finished grade or residential driveways Minimum of 10 feet from top of attached deck or porch Minimum of 3 feet lateral clearance from an openable window Minimum of 15 feet if voltage exceeds 300 volts to ground Minimum of 18 feet over public streets, alley, roads, parking lots, areas subject to truck traffic, driveways other than residential (i.e. cultivated land, grazing, forest or orchard land). Overhead conductors cannot cross more than 3 linear feet of roofline. **For more detailed information regarding number 7, see Articles and The Service disconnect (Main Breaker) shall be bonded and grounded in accordance with Article 250. All service entrance conduits shall be bonded in accordance with Article Required Grounding for Service disconnect (2 required) a) Eufer (footer) ground (steel tied to reinforcing steel in footer, and protruding from the footer) Connect w/ #4Bare Copper b) 2 each 5/8 x 8 ground rods driven a minimum of 6 feet apart connected with #6 bare copper at meter pole and house c) Water pipe ground (only if metal pipe entering structure minimum of 10 linear feet in ground d) 12 X 12 X 1/8 ground plate (copper) e) Ground Ring (minimum of 20 #4 bare copper in ground 30 inches deep f) Made electrodes per Article Required Bonding for Service Disconnect a) All Metal piping in structure (i.e. water, gas (if black pipe?) b) Service Entrance conduits (if metal) Note: ALL grounding connections must be and remain accessible and unspliced 100 Ampere Service = #6 Copper 200 Ampere Service = #4 Copper 11. Service Disconnect cannot be located in a bathroom or a closet. 12. Any and all sub-panels beyond the service disconnect shall be 4 wire, (2 hot, 1 neutral, 1 ground) connections separate neutral and ground bars required.
11 D. Article Requirements for dwelling unit receptacles. Table (A) 1. General Lighting and receptacle loads shall be computed at 3 VA (watts/)ft2 Example: 1) Living Room 15 X 20 = 300 2) Family Room 10 X 15 = 150 Total 450 ft2 x 3 VA = 1350VA 15 amp circuit at 100% = 1800va X.8 = 1440 VA allowed. Therefore: These two rooms (all lighting and receptacles) are allowed to be served by one15 ampere branch circuit. 2. Location of Receptacles is as follows: See Article 210 for more details. d) 6 feet from each door opening, then no more than 12 feet there after, around room, in each habitable room. e) 1 receptacle in hallways longer than 10 feet is required. f) 2 receptacles on outside of residence: 1 in front and 1 in back of structure within 6 feet 6 inches of finished grade (GFI required) g) On Kitchen countertops required every 4 feet on counter spaces greater than 12 long (GFI required) h) 1 receptacle required in each peninsula or island with less than 6 inches of counter overhand. (GFI required) i) 1 receptacle required within 36 inches of each bathroom sink (GFI required). j) 1 receptacle in unfinished basement (GFI required) k) 1 receptacle in garage (GFI required) l) 1 receptacle within 25 feet of equipment (i.e. furnace, water heater, etc.) GFI required. 3. Each habitable room, unfinished basement, garage and storage areas shall have means by which to operate at least 1 light opening (light fixture, or switched receptacle). See Article 210 for more details. 4.Illumination is required at each man door (egress lighting) for the purpose of escape in the event of fire. See Article 210 for more details. 5. Require Circuits a) 2 each kitchen appliance (counter-top) circuits 20 Ampere b) 1 each Laundry (washer) circuit 20 Ampere c) 1 each Bathroom receptacle circuit 20 Ampere d) 1 each Disposal/Dishwasher circuit (20 A for both) 20 Ampere This feed can also consist of 2 each 15-Ampere circuits e) 1 each Microwave circuit (only if microwave built in) 20 Ampere f) 1 each Heat (boiler or furnace) circuit 15 Ampere g) 1 each Water Heater circuit (if electric) 30 Ampere h) 1 each Dryer Circuit(if electric) 30 Ampere i) 1 each Well circuit (must be adequate for Pump) 20 or 30 Ampere j) 1 each Jacuzzi Tub circuit 20 Ampere
12 There circuits are required to serve the above-mentioned items only. There are two exceptions for (B) Laundry circuits; items can serve additional receptacles in the laundry room, but cannot leave it. Exception to (A) kitchen appliance circuit; are allowed to serve the dining room receptacles if there are a low number of kitchen counter receptacles. The balance of the dwelling is required to have only the number of additional circuits per the load calculation done, based on the square footage of the dwelling. 6. Special Protection: New for 2002: Arc fault interrupter circuits. See Article These devices are intended to sense faults know as arcing, and are designed to de- Energize the circuit if this occurs. All bedroom openings (i.e. lighting openings, receptacles, and smoke detectors (throughout the entire house) must be served by Arc- Fault Interrupting Breakers. 7. Ground Fault Interuptor (GFCI) required locations. See Article for more details. 1. Bathrooms 2. Garages (storage areas) 3. Outdoor Receptacles 4. Crawl Spaces 5. Un-Finished basements 6. Kitchens (counter-top receptacles) 7. Wet Bar Sinks (any receptacle located within 6 feet of outside edge of the wet bar sink) 8. Boathouses Smoke detectors for dwelling units must be located per plan review drawings and must be interconnected throughout the entire dwelling (3 wire). They must be powered both with 120 volts AC current, and must be backed up with batteries in the event of a power failure. E. Wiring Methods 1) Wiring of dwelling may not begin until the structure is effectively dried in. This means all doors and windows installed, and a minimum of at least tarpaper on the roof. It is also highly recommended that mechanical, plumbing, and other sub-contract trades have their portions of work already completed. 2) Drilling of Holes: Holes in which to pull NM-B wires may be drilled anywhere in walls, however if there is less than 1 ¼ of wood remaining between the stud-fact and the hole, then a 16 gauge nail plate (notch plate) is to be installed to prevent damage to wire by dry wall nails or screws. 3) Wire must be supported (stapled) every 4 ½ per Article At entry to every box the wire must be stapled no more than 12 away. At least ¼ of the outside sheating but no more than ¾ must be installed inside the box. Sizes of required outlet boxes can be found in Article 314. This Article also explains how wire-fill is to be calculated for each outlet box. A minimum of 6 of wire must be left in the box from the point of where it emerges from its raceway in the box. See Article for more details. All wiring
13 within the junction boxes must be joined physically (wire nuts or compression barrels for grounds). Any and all metallic boxes are to be grounded (bonded) by ground screws, or other approved methods for grounding. Any outlet box that is used for the purpose of joining wires (not containing devices or lighting fixtures) is to remain accessible (cannot be covered in walls). All wiring located within 7 feet of attic access holes must be protected from physical damage, either by stapling to the side of roof truss, or nailing protective strips 2 X 4 on edge next to conductors. If garage walls remain unfinished, wiring must run vertically up walls to a height of 8 feet before running horizontal to be considered not subject to physical damage. Please make note of the following amendments to the Teller County Building Code: Article VII Amend section and add paragraph: (F) Protection from Damage of Riser on Unfused Service Laterals. Direct buried conductors (Unfused Service Laterals) shall be buried at a depth of no less than 30 inches, and shall have a yellow warning ribbon placed at least 12 inches above the underground electrical installation. Protection from physical damage shall be provided with the installation of Galvanized Rigid Conduit Rigid Metal Conduit only. Amend Article and add paragraph: (B)(4). Reduced Neutrals 1. The reduction of neutral feeder wire, URD (Underground Rated feeder wire), shall not be allowed. 2. The reduction of neutrals for service feeders shall not be allowed.
RESIDENTIAL BUILDING REQUIREMENTS
RESIDENTIAL BUILDING REQUIREMENTS Residential Building Requirements This is an informational booklet with some of the general residential construction requirements taken from the codes adopted by Campbell
More informationPermit Posting and Inspection Procedures
Permit Posting and Inspection Procedures Boone County Area Plan Commission 116 Washington Street Room 101 * Lebanon, IN 46052 * (765) 482-3821 * www.boonecounty.in.gov/apc 1. Permit. The following permit
More information2003 International Residential Building Code
2003 International Residential Building Code Section R305 Ceiling Height Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less
More informationLonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)
Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN 55046 (507) 744-2327 fax (507) 744-5554 2006 RESIDENTIAL CONSTRUCTION CHECKLIST The following checklist has been designed
More information2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
More informationContractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.
FINISH BASEMENT/ADDITION/REMODEL PLAN CORRECTIONS LIST (Based on the current Editions of the International Codes and National Electrical Code) PLAN CHECKED BY: LOT/SUBDIVISION/ADDRESS: CONTRACTOR OR OWNER/BUILDER:
More informationPulaski County, Virginia
Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Foundation and Floor... 3
More informationDEPARTMENT OF PLANNING SERVICES BUILDING INSPECTION DIVISION 1555 N 17 TH AVENUE, GREELEY, CO (970)
DEPARTMENT OF PLANNING SERVICES BUILDING INSPECTION DIVISION 1555 N 17 TH AVENUE, GREELEY, CO 80631 (970) 400-6100 BASIC REQUIREMENTS FOR WIRING A SINGLE FAMILY DWELLING Colorado State law permits individuals
More informationCODE COMPLIANCE GUIDELINE GENERAL BUILDING
CODE COMPLIANCE GUIDELINE This guideline has been prepared by The Calhoun County Building Department to assist Homebuilders, General Contractors, and Owner/Builders during the construction process. The
More informationBASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)
BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from
More informationTypical Finished Basement Details
Albemarle County, Virginia Typical Finished Basement Details Based on the 2012 Virginia Residential Code Finished basements must be constructed in conformance with these details. For requirements, details
More informationRESIDENTIAL BASEMENT ALTERATIONS GUIDE
RESIDENTIAL BASEMENT ALTERATIONS GUIDE THIS IS A GUIDE ONLY! FOR DETAILED INFORMATION, CONTACT THE BUILDING INSPECTOR OR TOWNSHIP AS ADDITIONAL REQUIREMENTS MAY PERTAIN TO YOUR PROJECT. November 2018 WHITEHALL
More informationBasic Requirements for Residential Electrical Installations
Basic Requirements for Residential Electrical Installations Wayne County Building Department 428 West Liberty Street Wooster, Ohio 44691 Phone: 330-287-5525 Fax: 330-287-5649 This brochure is intended
More informationAPPLICATION FOR FINISHED BASEMENT PERMIT
APPLICATION FOR FINISHED BASEMENT PERMIT REAL ESTATE TAX I.D. #: - - _ - _ 7607 W College Drive Ph: (708) 361-1804 Fax: (708) 923-7112 building@palosheights.org APPLICANTS: COMPLETE ALL ITEMS AND SUBMIT
More informationBASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS
BASEMENT FINISH REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS A construction permit is required. A homeowner may perform the construction work on his own property where he resides, without a
More informationCity of Santa Monica Building and Safety Division
This is to be used as a general checklist; it is not inclusive of all code requirements and inspection criteria. General requirements Verify that address on permit matched Address, Description and Approvals:
More informationHomeowner electrical wiring guide. Including the 2015 Canadian Electrical Code amendments
Homeowner electrical wiring guide Including the 2015 Canadian Electrical Code amendments Table of Contents Homeowner electrical wiring guide... 1 Required inspections... 2 Rough inspections (prior to any
More informationRESIDENTIAL BUILDING PLAN REQUIREMENTS
CITY OF MANSFIELD BUREAU OF BUILDING AND CODES 30 NORTH DIAMOND STREET 3RD FLOOR MANSFIELD, OHIO 44902 Phone (419) 755-9688 Fax (419) 755-9453 www.ci.mansfield.oh.us RESIDENTIAL BUILDING PLAN REQUIREMENTS
More information* RESIDENTIAL PLAN REVIEW *
CITY OF DES MOINES, IOWA COMMUNITY DEVELOPMENT DEPARTMENT PERMIT AND DEVELOPMENT CENTER 602 Robert D. Ray Drive DES MOINES, IOWA 50309 Phone: 515.283.4200 Facsimile: 515.283.4270 Based on the scope of
More informationFairfax County, Virginia
Fairfax County, Virginia Typical Finished Basement Details Based on the 2009 International Residential Code CONTENTS General Requirements... 2 Emergency Escape and Rescue... 2 Wall Construction... 3 Floor/ceiling
More informationHUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT
HUMBOLDT COUNTY BUILDING & SAFETY DEPARTMENT CITY OF WINNEMUCCA BUILDING DEPARTMENT FOR PRIVATE THREE-SIDED POST FRAMED (NON-ENGINEERED) OUTBUILDINGS LOCATED ON RESIDENTIAL LOTS ONLY Buildings must meet
More informationElko County Building & Safety Division
Elko County Building & Safety Division 540 Court St., Suite 104, Elko, Nevada 89801 (775) 738-6816, Fax (775) 738-4581 www.elkocountynv.net Residential Design Criteria & Checklist One & Two Family Dwellings
More informationEFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,
TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2011 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.
More informationResidential Building Plans
Residential Building Plans 1. Building Site Plan indicating: a. Location of Proposed and Existing Buildings b. Location of Property Lines c. Building Setback Dimensions d. Location and Depth of Building
More informationRESIDENTIAL CONSTRUCTION New Dwellings and Additions
How to Obtain a Building Permit For RESIDENTIAL CONSTRUCTION New Dwellings and Additions MIAMI COUNTY, KANSAS CODE SERVICES DEPARTMENT 201 South Pearl Street, Suite 201 Paola, Kansas 66071-1777 Phone:
More informationINFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS
INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS November 2018 Contents 1. Introduction... 1 2. Ontario Building Code and Second Dwelling Units... 1 3. How Do I Make My Secondary Dwelling Unit
More informationBasement Finish. City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN (952) Fax (952)
Basement Finish City of New Prague Building Inspections Department 118 Central Ave N New Prague, MN 56071 (952)758-4401 Fax (952)758-1149 PERMIT AND BUILDING CODE REQUIREMENTS PERMIT SUBMITAL CHECKLIST:
More informationTOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION
TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.
More informationOne and Two Family Additions
One and Two Family Additions An addition to a house, duplex, garage, or an accessory structure requires a building permit prior to performing any construction. Building Department & Permit Office Mon-Fri
More informationThe Inspection Process. Waxhaw N.C.
The Inspection Process In Waxhaw N.C. This information is provided by the Waxhaw Enforcement Division to assist you in the progression of your project. Nothing in this document should be considered "Code"
More informationRe-inspections due to failed work or jobs that are not accessible cost both contractors and city inspectors time and money.
1 Re-inspections due to failed work or jobs that are not accessible cost both contractors and city inspectors time and money. This information has been assembled to share SOME common Building Code violations
More informationRENTAL INSPECTION CHECKLIST. Helpful Definitions: Egress: the free and unobstructed access to the exterior of a habitable space.
CITY OF MANASSAS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION 9027 Center Street, Room 201, Manassas, VA 20110 P.O. Box 560 Manassas, VA 20108 Phone: 703-257-8278 Fax: 703-257-5831
More information1 & 2 Family Garage/Shed Permits City of Oshkosh Inspection Services Division
This handout will help guide you through the permit application process. Following the steps below will help to expedite the issuance of your building permit. Please plan ahead and pick one of the following
More informationCITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET. Adopted Codes:
CITY OF FATE SINGLE FAMILY BUILDING PERMIT PACKET Adopted Codes: 2015 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL PLUMBING CODE 2015 INTERNATIONAL ENERGY CONSERVATION
More informationFRAMING INSPECTION GENERAL
FRAMING INSPECTION GENERAL 20 FRAMING INSPECTION GENERAL Tips Check habitable rooms for minimum light, ventilation and sanitation requirements. Check that stair framing meets headroom, width, and rise
More informationOregon Building Officials Association
Oregon Building Officials Association Oregon Building Officials Association Inspector s Checklist 2010 Oregon Manufactured Dwelling Installation Specialty Code November 5, 2014 By: Frank Scheer, Building
More informationRepair or replace section of driveway, approach, or sidewalk that are a trip hazard.
City of Gibraltar Pre-Sale Inspection Report Checklist FLATWORK: Repair or replace section of driveway, approach, or sidewalk that are a trip hazard. EXTERIOR PROPERTY: Fences/Sheds/Retaining walls: Repair,
More informationResidential Accessory Structures & Room Additions
Residential Accessory Structures & Room Additions Planning and Development Services Department Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email:
More informationSection numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.
Residential Plan Check Addendum Page 2 of 5 Building Permit # Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept. 5 th,
More informationFINISHED BASEMENT REQUIREMENT GUIDE
Basement Guide www.douglas.co.us FINISHED BASEMENT REQUIREMENT GUIDE Current Codes: 2012 International Residential Code 2009 International Energy Conservation Code 2011 National Electrical Code 2012 I-Code
More informationCITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS
CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS Update April 29, 2013 12 Permit application forms and contact information can be found on our website under Inspection Department
More informationHOMEOWNER PERMITS AND ELECTRICAL WIRING GUIDE
HOMEOWNER PERMITS AND ELECTRICAL WIRING GUIDE Revised 20 1 APPLICATION FOR HOMEOWNER PERMITS This pamphlet is only a guide. It describes methods of installation that have been tried and tested and which
More informationTown of Chili. building department 3333 chili avenue, Rochester, ny (585) fax: (585)
David J Dunning Supervisor Virginia L. Ignatowski Town Clerk Town of Chili building department 3333 chili avenue, Rochester, ny 14624 (585) 889-6143 fax: (585) 889-8710 Finishing Basements: What You Need
More informationPulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code
Pulaski County, Virginia Typical Carport Enclosure Details Based on the 2012 International Residential Code Carports enclosed into one-story garages or living spaces must be constructed in conformance
More information2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING
2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending
More informationBUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)
BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL 32907 Phone: (321) 953-8924 Fax: (321) 953-8925 CUSTOMER SERVICE INFORMATION ON RESIDENTIAL PLAN REVIEW REQUIRED DOCUMENTS MUST BE SUBMITTED AT TIME
More informationBasement Build-Out Guidelines
Community Development Department Five Plaza Drive Woodridge, IL 60517-5014 (630) 719-4750 FAX (630) 719-2900 Basement Build-Out Guidelines The Village of Woodridge requires that a building permit be submitted
More informationSt. Clair County Electrical Code Regulations
St. Clair County Electrical Code Regulations St. Clair County has adopted the 2011 National Electrical Code as amended with the following listed articles as the St. Clair County version of the National
More informationCITY OF GRANDE PRAIRIE
Inspection Services CITY OF GRANDE PRAIRIE HOMEOWNER S PERMIITS AND WIRING GUIDE FOR ELECTRICAL INSTALLATIONS 2016 INDEX Page Applying for an Electrical Permit 3 Permit Application Requirements 3 Permit
More informationINFORMATIONAL HANDOUT FOR FINISHING A BASEMENT
7100 147 th Street West Telephone (952) 953-2588 Apple Valley, MN 55124-9016 Fax (952) 953-2515 www.cityofapplevalley.org INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT 1. Submit plan showing the proposed
More informationACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings
ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings Building Safety Department 400-2 nd Street South St. Cloud, MN 56301 (320) 255-7239 A building permit is required for any accessory
More informationADDENDUM A CONSTRUCTION SPECIFICATIONS
ADDENDUM A Description of Improvements: CONSTRUCTION SPECIFICATIONS The Improvements shall consist of constructing an approximate square foot single-family residence including car garage on the real property
More information1 AND 2 FAMILY DWELLING REQUIREMENTS
PLAN REQUIREMENTS: 1 AND 2 FAMILY DWELLING REQUIREMENTS All residential plans including additions and attached garages shall be designed to the current edition of the International Residential Code. Plans
More informationCarroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage
Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public
More informationResidential Building Inspections
Residential Building Inspections Foundations, Grade Beams, Pile Caps, Foundation Pads 1. All trenches or excavations and formwork shall be in accordance with the size(s) and configuration(s) as per approved
More informationADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)
ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008) PERMIT SUBMITTAL CHECKLIST: Signed completed Building Permit application form. Two (2) Copies of a Certificate of Survey. Draw to scale the
More informationCity of Santa Monica Building and Safety Division
This is to be used as a general checklist; it is not inclusive of all code requirements and inspection criteria. GENERAL REQUIREMENTS Approved plans and inspection card to be on job site. (CBC 106.4.2
More informationGENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches
GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches and shall be sized to carry the applicable roof and
More informationAdministrative Changes
Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings
More informationInspection Report. Property Address:
Inspection Report provided by: Safe Side Home Inspection Inspector: Corey Stuart TN License # 778 434 Margaret Circle McMinnville, TN 37110 safesideinspection@blomand.net Property Address: 1234 Anywhere
More informationApplying for Permits to build a new house in Linn County
Planning & Development Linn County, Iowa Building Division Linn County Building Code Residential Guidelines Single Family Dwellings Page 1 of 4 Applying for Permits to build a new house in Linn County
More informationMinimum Requirements for Residential Occupancy Codes and FAQs
City of McMinnville, Planning & Zoning Department 101 East Main, McMinnville, TN 37110 (931) 473-1204 Fax (931) 473-6231 Email: nming@mcminnvilletenn.com Minimum Requirements for Residential Occupancy
More informationGeneral Requirements for Mobile Homes
Mobile homes shall conform in all respects to the CAN/CSA-Z240 MH Series of Standards and shall be complete structurally with the entire plumbing, electrical, and heating services installed. Prior to moving
More informationCOMMERCIAL / INDUSTRIAL GENERAL INFORMATION FOR TENANT SPACE ALTERATION & REMODELING
COMMERCIAL / INDUSTRIAL GENERAL INFORMATION FOR TENANT SPACE ALTERATION & REMODELING COMMUNITY DEVELOPMENT DEPARTMENT (847) 506 6030 www.cityrm.org/rmcd SUBMIT CONSTRUCTION DOCUMENTS Building Plans FOUR
More informationHome Inspection Report
Home Inspection Report Example Home Inspection Report. Page 1 of 17 Table of Contents Definitions 2 Company Information 2 General Information 2 Lots and Grounds 3 Exteriors 3 Garage/Carport 4 Roof 5 Attic
More informationThe Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits
The Compass ( 270 Lisgar Street, Brighton ) Features General Site Work 1. Construction Drawings 2. Building, Plumbing Electrical and Entrance Permits 3. Development and Septic Fees 4. Tarion New Home Warranty
More informationRESIDENTIAL PLAN CHECK LIST
RESIDENTIAL PLAN CHECK LIST Based on the 2013 California Residential Code (CRC) City of Hermosa Beach - Building Department 1315 Valley Drive Hermosa Beach, CA 90254 (310) 318-0235 General 1. Legal Owner,
More informationTOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX
TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ 08014 856-467-3626--- FAX 856-467-9260 Application for Certificate of Occupancy for Change of Occupancy Pursuant to Chapter 119 of the Township
More informationUCC Permit Application Procedures
How do I apply for a permit? UCC Permit Application Procedures 1. Please complete the CodeMaster Pan Review Application 2. Please provide the scope of work description and/or construction documents/plans.
More informationPLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Construction requirements for LOWER LEVEL DEVELOPMENT in residential dwellings January 2018 contents GENERAL INFORMATION... 3 BUILDING CODE REQUIREMENTS...
More informationTOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,
BUILDING PERMIT REQUIREMENTS FOR BASEMENT REMODELING 1. Provide two copies of a detailed floor plan and elevation drawing, see sample drawings on page 9 and 10. Include materials, sizes, supports, heating,
More informationFINISHED BASEMENT REQUIREMENT GUIDE
Basement Guide www.douglas.co.us FINISHED BASEMENT REQUIREMENT GUIDE Current Codes: 2012 International Residential Code 2009 International Energy Conservation Code 2014 National Electrical Code 2012 I-Code
More informationREO Client Safety Hazard Requirements
REO Client Safety Hazard Requirements Safety Hazards Safeguards clients are continually reporting missing safety hazards or allowables across the nation and it is jeopardizing our relationship with our
More informationTHE FLORIDA BUILDING CODE
THE FLORIDA BUILDING CODE 1. According to the Florida Building Code, spiral stairway treads must all be identical and rise must be sufficient enough to provide a headroom of minimum. A. 6'- 4" B. 6'- 6"
More informationHARPER WOODS BUILDING DEPARTMENT PROCEDURES FOR OBTAINING CERTIFICATE OF OCCUPANCY
HARPER WOODS BUILDING DEPARTMENT PROCEDURES FOR OBTAINING CERTIFICATE OF OCCUPANCY A Certificate of Occupancy is required for all properties within the City. Residential certificates are valid for one
More informationThe Home Doctor, Inc.
February 7, 2013 The Home Doctor, Inc. Property: 26147 HUNTER GATES RD. LESTER, AL 35647 Client: JOHN DOE HOME INSPECTIONS With over 10,000 since 1994 1-800-246-4362 SUMMARY PAGE CLIENT(S): JOHN DOE ADDRESS:
More informationEFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp,
TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2008 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.
More informationSCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements
SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC. 320-226.5189 www.101developmentresources.com While every attempt has been made to insure the correctness of this handout, no guarantees are made to its accuracy
More informationR vertical and horizontal.
CITY OF WENTZVILLE RESIDENTIAL CODE PLAN REVIEW CHECK LIST Items indicated with an X are to be addressed by incorporation into revised plans. A checkmark indicates O.K. Date: Lot # Subdivision: Address:
More informationRental Inspection Checklist
Rental Inspection Checklist Address: Date: NOTE: The water, gas and/or electrical services were off at the time of inspection. A re-inspection at a later date SHALL BE required to inspect these items.
More information2012 Code Update Training
2012 Code Update Training VIRGINIA RESIDENTIAL CODE Jack A. Proctor Virginia Building Code Academy Department of Housing and Community Development R202 Definitions BASEMENT R202 Definitions Story Above
More informationBuilding Permit Application
Building Permit Application Administrative Use Only PARENT PERMIT NUMBER (Required if part of another project) PERMITTEE: PERMITTEE ADDRESS: E-MAIL ADDRESS: ARCHITECT/ENGINEER: ARCHITECT/ENGINEER ADDRESS:
More informationResidential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016
February 2016 Residential Deck Safety, Construction and Repair Juneau Permit Center, 4 th Floor Marine View Center,(907)586-0770 This handout is designed to help you build your deck to comply with the
More information$ Plan Review Fee when Permit Application is submitted BASEMENT REMODEL BUILDING PERMIT APPLICATION. Status Sticker OFFICIAL USE ONLY
Community Development 1050 W Romeo Rd, Romeoville, IL 60446-1530 (815) 886-7200 Fax #: (815) 886-2724 Email: buildinginspections@romeoville.org BASEMENT REMODEL BUILDING PERMIT APPLICATION Property & Owner
More informationPENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal
PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal Roof Size: Width: Length: Roof Type: Gable: Hip: Shed: Roof Pitch: (check one) Trusses: Rafters: Spacing of Trusses or Rafters:
More informationSUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:
IRC CODE UPDATES TO: RESIDENTIAL BUILDING CONTRACTORS FROM: GARY STABER, BUILDING OFFICIAL SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE: 6/1/2003 INTERNATIONAL RESIDENTIAL CODE (IRC) APPLICABILITY:
More informationBROCHURE # 108 CONSTRUCTION PLAN COMPONENTS
BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS Please note: This construction plan component list is to be used as a guide to assist you with your project. There may be elements unique to your project not
More informationTypical Finished Basement Details
Town of Merrimac, Ma Typical Finished Basement Details Based on the 2009 International Residential Code Finished basements must be constructed in conformance with this document. For requirements, details
More informationPENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION
PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION Permit No. 175 Beaver Drive, P.O. Box 486 DuBois, PA 15801 Phone: 814-375-1111 Fax: 814-375-1117 Toll Free: 855-PENNSAF LOCATION OF PROPOSED
More informationTable of Contents. Page Title
Page Title Table of Contents 1 Floor plan/ Room utilization 2 Elevation (EAST) 3 Elevation (SOUTH) 4 Elevation (WEST) 5 Elevation (NORTH) 6 Foundation plan details 7 Foundation cross sections A Main grade
More informationBUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS
BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS Permit Required Any owner or authorized agent who intends to construct, enlarge,
More informationInspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011
Inspection Report Prepared for: Gil Turiel Property Address: Loganville, GA 30052 Date: July 17, 2011 Inspector: Charles Mann (770) 594-2222 www.edificeinspections.com Page 1 INSPECTION CONDITIONS CLIENT
More informationIMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013
IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013 2011 National Electrical Code (NEC) Update Statement The National Electrical Code, 2011 Edition, with Appendices,
More informationNORTHEASTERN REMC ELECTRIC STANDARDS MANUAL
NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.
More informationROUTT COUNTY REGIONAL BUILDING DEPARTMENT 136 * P.O.
ROUTT COUNTY REGIONAL BUILDING DEPARTMENT 136 6 th Street * P.O. Box 773840 * Steamboat Springs, CO 80477 (970)870-5566 * FAX (970)870-5489* Email: Building@co.routt.co.us INSPECTIONS POLICY SCHEDULING
More informationRESIDENTIAL REMODELING AND BASEMENT FINISH
RESIDENTIAL REMODELING AND BASEMENT FINISH CITY OF HUTCHINSON BUILDING DEPARTMENT 111 Hassan Street SE, Hutchinson, MN 55350 Phone: (320) 234-4216 Web Site www.ci.hutchinson.mn.us/building.htm This handout
More informationOne & Two Family Residential ADDITIONS
City of St. Petersburg Development Services One & Two Family Residential ADDITIONS (Effective Date: 5/1/03) This checklist is subject to change and improvement at any time. Please determine that you have
More informationSFR SUBMITTAL REQUIREMENTS
A. FEES DUE AT TIME OF PERMIT APPLICATION The following non-refundable fees will be collected at the time of application for all residential projects. 1. Building Plan Check Fee B. CODES The City of Oak
More informationBasic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc.
Basic Information for Obtaining Permits, Submitting Plans, Scheduling Inspections, etc. Franklin County Septic & Zoning permit application: A septic and zoning permit is required for residential or commercial
More informationTOWN OF FRANCESTOWN BUILDING/CODE ENFORCEMENT 27 MAIN STREET P.O. BOX 5 FRANCESTOWN, NEW HAMPSHIRE Building Permit Application Guide
TOWN OF FRANCESTOWN BUILDING/CODE ENFORCEMENT 27 MAIN STREET P.O. BOX 5 FRANCESTOWN, NEW HAMPSHIRE 03043-0005 TELEPHONE (603) 547-3469 EMAIL francestownnh@comcast.net FAX (603) 547-2622 Building Permit
More information