BUILDING CODE PRESENTATION

Size: px
Start display at page:

Download "BUILDING CODE PRESENTATION"

Transcription

1 BUILDING CODE PRESENTATION June 3, 2015 Wendy Morrison, AScT, BCQ Fire Science and Engineering Granville Street Vancouver, BC V6C 1T2 Phone Fax

2 Copyright and Limitations This presentation is conceptual and for educational purposes only. GHL takes no responsibility for application of any concepts or interpretations in this presentation to specific projects unless specifically retained for that project. This presentation is intended to be presented by GHL and these slides must not be considered complete or exhaustive. This presentation is a copyright of GHL Consultants Ltd and all rights are reserved. 2

3 GHL s Role To know and understand the Code. Toknowandunderstandthefiresciencebehindthe Code. To assist in correct application of the Code. To develop new solutions based on fire science to enable creative safe buildings. To understand the needs of the client and of the Authorities and first responders. 3

4 GHL Team 7 Engineers, 4 with Master s degrees in fire science. 4 Certified Professionals (CPs). 1 Architect. 2 former Building Officials. 3 Building Code Qualified (BCQ). 1 Architectural Technologist. 4

5 Building Code Committee Work CP Committee (David Graham) APEG Building Code Committee (John Buscemi) BC Appeal Board (Frankie Victor) City Vancouver Appeal Board (Teddy Lai) BC Building Code Interpretation Committee (Teddy Lai) 5

6 What is a Building Code? It is a consensus document: It regulates construction of buildings. Traditionally written by NRCC. The province adopts it on the public s behalf. Code measures are public interest decisions. VBBL 2014 based on BCBC

7 Code Approach To Risks Buildings are subject to risks: Code compliance no risk. Code compliance = risks at acceptable level. Failure will occur: Limit it to an acceptable level. 7

8 Objective Based Code 2006 and 2012 Codes are objective based rather than prescriptive based a fundamental change from previous editions. Prescriptive Code says how you must do it. Exception is an equivalency. Objective Establishes function and objectives. Prescriptive requirement is only 1 option (acceptable solution). An alternative solution may be proposed provided it satisfies the level of performance attributed to the acceptable solution. 8

9 Alternative Solutions Article Compliance with the Code shall be achieved by: a) Complying with the applicable acceptable solutions in Division B; OR b) Using alternative solutions that will achieve at least the minimum level of performance required by Division B in the areas defined by the objectives and functional statements attributed to the applicable acceptable solutions. 9

10 Acceptable Solutions DIVISION A, PART 1, SUBSECTION APPLICATION OF THIS CODE Article Application of this Code 1) This Code applies to any one or more of the following: o) the alteration, rehabilitation and change of occupancy of heritage buildings. 5) The Alternate Compliance Methods for Heritage Buildings in Table A (1) in Appendix A may be substituted for requirements contained elsewhere in this Code. Article Application to Existing Buildings 1) Where a building is altered, rehabilitated, renovated or repaired, or there is a change in occupancy, the level of life safety and building performance shall not be decreased below a level that already exists. (See Appendix A.) Appendix A, Article Application of this Code The use of the Alternate Compliance Methods in Table A (1) is not mandatory, and an owner may choose: to apply acceptable solutions in Division B, to apply alternate solutions under Clause ( 1)(b), to apply alternate compliance methods in Table A , or to combine these options. 10

11 Acceptable Solutions Table A (1) Alternate Compliance Methods for Heritage Buildings No. Code Requirement in Division B Alternate Compliance Method 1 Fire Separations Sentence (1) and Table of Division B, Subsection of Division B 2 h fire separation required between some major occupancies. Except for F1 occupancies, 1 h fire separation is acceptable, provided the building is sprinklered. 11

12 Part 9 Small buildings: 3 storeys in height 600m² building area building area = greatest horizontal area above grade, e.g. footprint or shadow cast. Excludes assembly (Group A), care/treatment/detention (Group B), high hazard industrial (Group F 1) occupancies. Generally unsprinklered by Code. 12

13 Part 3 > 600m² building area and/or 3 storeys in building height. All occupancies including assembly (Group A) and care/treatment/detention (Group B). Generally, sprinkler systems required by Code. 13

14 Occupancies (3.1.2, 3.1.3) GROUP A GROUP B GROUP C GROUP D GROUP E GROUP F Assembly Division 1 = theatre Division 2 = restaurant, pub, daycare, yoga/fitness studio Division 3 = arena Care/Detention Division 1 = jail Division 2 = hospital Division 3 = care facility Residential = dwelling, hotel Business and Personal Service = office, doctor/dentist, barber, bank, yoga/ fitness studio Mercantile/Retail = stores, shops, showrooms Industrial Division 1 = Heavy Division 2 = Medium Division 3 = Light See descriptions at Division B, A (1) 14

15 Major Occupancy vs Suite Occupancy based on type Group A, B, C, D, etc. Occupancy may include multiple suites of same type. Occupancies must be separated per Article Occupancy fire separations will vary 0h to 2h fire. Suite separations will apply in addition to occupancy separations. 15

16 Major Occupancy vs Suite Suite based on tenancy. Within one suite, may be various ancillary occupancies. Ancillary occupancies must be under the care and control of the same tenant. [e.g. gift shop in hospital; amenity room in residential; Starbucks in Chapters See Appendix A, A (1) Suite]. Suite fire separations per Article

17 Ancillary Occupancies Midas Muffler Office Office Office Hotel Suites Hotel Suites Hotel Suites Lounge Pool Spa Office Office Office Office Office Fitness 17

18 Occupancy Prohibitions Apartment C Auto Body Shop F1 Nightclub A2 18

19 TOPICS Part A BCBC 2012: Overview of Relevant / Key Changes to Division B, Part 3, BCBC 2006 and and Subsequent Revisions to BCBC 2012 Part B BCBC 2012: Select issues from Section 3.8 "Building Requirements for Persons with Disabilities" Part C Part D BCBC 2012: Provisions for Combustible Interior Finish Summary 19

20 A. BCBC 2012: Part 3 Changes ERRATA AND REVISIONS 20

21 A. BCBC 2012: Part 3 Changes ERRATA AND REVISIONS 21 and revisions.aspx?vid=qplegaleze:bccodes_2012_view

22 A. BCBC 2012: Part 3 Changes DEFINITIONS IN DIVISION A, SENTENCE (1) Distillery / Distilled Beverage Alcohol process plant where distilled beverage alcohols are produced, concentrated, or processed with facilities where concentrated products are blended, mixed, stored or packaged. beverage alcohol is produced by fermentation and contains more than 20% by volume of water miscible alcohol. These definitions were added to clarify that breweries and wineries are not high hazard industrial occupancies. 22

23 A. BCBC 2012: Part 3 Changes Fire Block a material, component or system that restricts the spread of fire (within a concealed space or from a concealed space to an adjacent space). Fire blocks are typically provided to isolate concealed spaces. 23

24 A. BCBC 2012: Part 3 Changes Fire Stop a system consisting of elements used to fill gaps between fire separations, between fire separations and other assemblies, or at penetrations of fire separations. Fire stops typically provided at penetrations. 24

25 A. BCBC 2012: Part 3 Changes Article Group A Division 2, Low Occupant Load Assembly occupancy suite with occupant load less than 30 can be considered Group D use. Unsprinklered building = 1h fire separation from remainder of building. Sprinklered building = 0h fire separation. Impact on approach to calculating occupant load and number of water closets required e.g. coffee shop, yoga studio. 25

26 A. BCBC 2012: Part 3 Anticipated change in next edition of BCBC. Based on accepted change to NBC 2015 (not yet adopted) to address current interpretation of Article (7) Factory Assembled Panels with Foamed Plastic Insulation. 26

27 A. BCBC 2012: Part 3 Article (7) use of factory assembled nonloadbearing interior wall or ceiling panels containing foamed plastic insulation Prohibits use of panels in noncombustible buildings with Group A 2, B, or C major occupancy. Effectively bans use of walk in cooler and freezer if AHJ interprets these to be building components rather than fixtures. 27

28 A. BCBC 2012: Part 3 Wording of change to NBC 2015 testing of fixture to specific standard necessary 28

29 A. BCBC 2012: Part 3 Changes Article Sentences 3 and 4 added. Addresses confusion with openings when fire resistance rating provided through membrane only and reliance on Appendix D. Use of 2 specific rated assemblies from Part 9 table A B permitted assembly consists of membrane and supporting members. Penetrations to be addressed as per Subsection

30 A. BCBC 2012: Part 3 Changes Table A B 30

31 A. BCBC 2012: Part 3 Changes Table Combustible Interior Finish in High Buildings Added provisions for Elevator Vestibules (when vestibules are required by the Code e.g. multi storey interconnected floor spaces ). New provisions for flame spread rating and smoke developed classification limits within elevator cars e.g. FSR 75/SDC 450 at walls and ceilings; FSR 300/SDC 450 at floors. 31

32 A. BCBC 2012: Part 3 Changes Sentence (2) Fire Alarm Annunciator and Zone Identification Added separate zone requirement for fire extinguishing system required by NFPA 96 (commercial kitchens). 32

33 A. BCBC 2012: Part 3 Changes Sentence (1) Manual Pull Stations Clarifies that pull stations required at exits only not at every door that leads to the exterior from a floor area. Clause (e) "every other egress facility that has been designed and identified as an exit and has all the features of a required exit" 33

34 A. BCBC 2012: Part 3 Changes Sentence (2) Egress Doorways When 2 egress doorways are required to serve a room or suite (e.g. Group D suite >200m2) the egress doors must be separated by a distance = at least 1/3 of the greatest diagonal of the room or suite. 34

35 A. BCBC 2012: Part 3 Changes Sentence (2) Egress Doorways The distance between egress doors is to be measured on a path that smoke would move Fire separations (floor to underside of floor slab above) can be used to increase this distance. 35

36 A. BCBC 2012: Part 3 Changes Sentence (2) Egress Doorways 36

37 A. BCBC 2012: Part 3 Requirement for exit doors to be separated by a distance of at least 1/2 the greatest diagonal of the floor area (min 9m) remains Article

38 A. BCBC 2012: Part 3 Alternately max distance between exits 9m if public corridor provided Article

39 A. BCBC 2012: Part 3 Changes Article Daycare Facilities Confirms that daycare facilities are assembly occupancy, Group A, Division 2, and not Group B treatment or care occupancy. Provides specific building or suite design criteria if daycare facility accommodates children under the age of 30 months. 39

40 A. BCBC 2012: Part 3 Changes Subsection Design of Hazardous Areas BCBC now includes provisions for floor areas used for the storage, handling, use, and processing of dangerous goods, including flammable and combustible liquids. Relies on Fire Code to determine classification of substances to apply provisions in Subsection

41 A. BCBC 2012: Part 3 Changes Article Headroom Clearance Minimum headroom in exits reduced to 2050mm from 2100mm. Measured from the tread surface or landing nosing to closest point above. 41

42 A. BCBC 2012: Part 3 Changes Subsection Exit Signs Green Running Man now the Code requirement. Provisions for photo luminescent signs. 42

43 A. BCBC 2012: Part 3 Changes Subsection Exit Signs In existing buildings, use of red signs typically recommended to maintain continuity throughout building If the proposed scope of work is such that it is practical to replace all exit signs within a building, upgrade to green signs may be requested by AHJ. 43

44 A. BCBC 2012: Part 3 Changes Sentence (3) Landing may not be required at exterior stair Landing not required at the bottom of an exterior stair or ramp when there is no gate, door, or fixed obstruction within 1100mm or a distance equal to the width of the stair or ramp. 44

45 A. BCBC 2012: Part 3 Changes Sentence (7) Handrails Height of handrails may be more than 965mm at landings; maximum height at landings 1070mm This change allows for better detailing of continuous handrails landings between flights. 45

46 A. BCBC 2012: Part 3 Changes Sentence (7) Handrails 46

47 A. BCBC 2012: Part 3 Changes Subsection Plumbing Facilities Waterless Urinals permitted in buildings with a water supply Sentence (2). 47

48 A. BCBC 2012: Part 3 Subsection Plumbing Facilities Sentence (4) ONLY applies if design includes 1 universal toilet room If multiple universal toilet rooms provided, Sentence (4) is not applicable. 48

49 A. BCBC 2012: Part 3 Occupant Load = Universal Toilet Room = 10 occupants 90 occupants divided 45 male, 45 female Group A 2 = 1 male WC and 2 female WCs Total fixtures = 4 2 Universal Toilet Rooms 100 occupants divided 50 male, 50 female Group A 2 = 1 male WC and 2 female WCs Total fixtures = 3 49

50 A. BCBC 2012: Part 3 Changes Subsection Plumbing Facilities Sentences (10) (11) Accessible Baths and Showers include changes to grab bar design Among other changes, now specifically refer to L shaped grab bars. 50

51 A. BCBC 2012: Part 3 Changes Article Counters Clarifies that accessible design only required at counters which serve the public and are intended as a work surface for extended business transactions. e.g. Insurance agencies, hospital admitting desks. 51

52 A. BCBC 2012: Resources Province of BC has an Appeal Process: appeal board meets monthly; applications must be submitted 1 month prior to meeting. Previous Appeals and decisions are available on line. Search by Code reference or topic keyword. 52

53 A. BCBC 2012: Resources BC Building Code Interpretation Committee: members from AIBC, Building Officials Association of BC; Plumbing Officials Association of BC, City of Vancouver, and APEG meet monthly to review and provide written interpretations to clarify Code. Application information and previous decisions can be found by indexes on BOABC website under Codes & Regulations tab. ations.html 53

54 A. BCBC 2012: Resources GHL Website. Library Tab: presentations, technical, illustrations, newsletter Topic specific information Links to other sites. 54

55 A. BCBC 2012: Resources 55

56 B. BCBC 2012: Disabled Access Article Subsection 3.8.2: Applies to new buildings Applies to all storeys of new construction and new construction portions (additions). 56

57 B. BCBC 2012: Disabled Access Article Subsection Exemptions: Subsection does not need to be applied to Retail shops with retail floor area <50m 2. Subsection does not need to be applied to Group C occupancies except as described in Article

58 B. BCBC 2012: Disabled Access Article Subsection not applicable at storeys above or below accessible storey in 2 storey building or suite, if: exempt storey <600m 2. exempt storey does not include facilities integral to the principal function of the accessible storey. exempt storey does not contain an assembly occupancy >100m 2. 58

59 B. BCBC 2012: Disabled Access Sentence (1) General requirements for all applicable buildings: Access from street (and off street parking) to main entrance. Access to all areas where work functions can reasonably be expected to be performed by persons with disabilities. 59

60 B. BCBC 2012: Disabled Access Sentence (1) General requirements for all applicable buildings: Access to accessible washrooms. In unsprinklered buildings, egress per Article options include: at grade exit ramps. floor area divided into 2 zones. residential balcony. 60

61 B. BCBC 2012: Disabled Access Sentence (2) General requirements for all applicable buildings: At least one Universal Toilet Room in each building (if location of UTR such that not available to all suites; provide UTR to serve cut off suites). 61

62 B. BCBC 2012: Disabled Access Sentence (2) General requirements for all applicable buildings: If building or suite occupant load >150, other public washrooms within building or suite to include at least 1 of each type of fixture provided designed to be accessible. e.g. sink, toilet, urinal, hand dryer, mirror, etc. 62

63 B. BCBC 2012: Disabled Access Apply use and occupancy specific requirements per Articles through In some cases, use and occupancy specific requirements waive general requirements in Article Example see Article Schools and Colleges (Sentence (1) waived). Example see Article Jails (accessibility waived except at main entry and visitor areas). 63

64 C. BCBC 2012: Combustible Interior Finish Construction (combustible / noncombustible). High building / sprinklered. Determine what is permitted. Determine what flame spread ratings are required. 64

65 C. BCBC 2012: Combustible Interior Finish Heavy Timber = COMBUSTIBLE. Fire Retardant Treated Wood = COMBUSTIBLE. Wood generally flame spread rating (FSR) 150. Fire Retardant Treated Wood generally FSR 25. Fire Retardant Treated Wood CAN/CSA 080 (see Article ). 65

66 C. BCBC 2012: Combustible Interior Finish Combustible construction Subsection Combustible interior wall and ceiling finish permitted. No restrictions on thickness or percentage. Foamed plastic to be protected (see Article ). Flame spread ratings per Subsection

67 C. BCBC 2012: Combustible Interior Finish Noncombustible construction Subsection Combustible blocking and nailing elements OK. Combustible millwork OK (described in Article ). Combustible flooring OK. Combustible raised flooring OK (described in Article ). Flame spread ratings per Subsection

68 C. BCBC 2012: Combustible Interior Finish Noncombustible construction Subsection Combustible interior wall and ceiling finish OK. Cannot exceed 25mm thickness. Cannot exceed FSR 150 at walls (see Sentence (2)). Cannot exceed FSR 25 at ceilings (see Sentence (3)). Further flame spread ratings per Subsection

69 C. BCBC 2012: Combustible Interior Finish Interior Finish Subsection Defined as any material that forms part of the interior surface of a floor, wall, partition, or ceiling Doors. Windows. Trim. Lighting elements at ceiling finish (light diffusers / lenses; may apply to fixtures if flush with ceiling). Carpet intended as the finished floor. 69

70 C. BCBC 2012: Combustible Interior Finish Flame Spread Ratings Subsection FSR determined per testing to CAN/ULC S102. FSR determined per Appendix D listings (see D 3.1). Paint/wallpaper over wood = FSR 150. Paint/wallpaper over gwb = FSR

71 C. BCBC 2012: Combustible Interior Finish 71

72 C. BCBC 2012: Combustible Interior Finish 72

73 C. BCBC 2012: Combustible Interior Finish Flame Spread Ratings Subsection Sprinklered Buildings: Walls = FSR 150. Ceilings = FSR 150. Sentence (3) at noncombustible construction. Light Diffusers = FSR 250. (when tested as described in Article ) Group A 1 Light Diffusers = FSR

74 C. BCBC 2012: Combustible Interior Finish Flame Spread Ratings Subsection Unsprinklered Buildings: Walls = FSR 150. Group A 1 and Group B walls = FSR 75. Ceilings = FSR 150. Group A 1 and Group B ceilings = FSR 75. Sentence (3) at noncombustible construction. Light Diffusers = FSR 250. (when tested as described in Article ) Group A 1 Light Diffusers = FSR

75 C. BCBC 2012: Combustible Interior Finish Flame Spread Ratings Subsection All Buildings: Exits = FSR 25. Up to 10% of wall or ceiling area may be FSR 150. Exit lobbies = FSR 25. Up to 10% of ceiling area may be FSR 150. Up to 25% of wall area may be FSR 150. Doors = FSR 200. Group A 1 doors = FSR 150. Doors within dwelling units N/A. Bathrooms in dwelling units = FSR

76 C. BCBC 2012: Combustible Interior Finish Article High Buildings Sprinklered Building: Applies only at Group B major occupancy. Applies in Elevator Cars. Limits FSR of floor surface. Adds Smoke Developed Classification to wall, ceiling, floor finish (testing to CAN/ULC S102). See Table

77 C. BCBC 2012: Combustible Interior Finish Article High Buildings Unsprinklered Building: Applies to buildings under Subsection Limits interior finish ratings at walls, ceilings, floors, elevator cars, and elevator vestibules Adds Smoke Developed Classification through testing to CAN/ULC S102. See Table

78 C. BCBC 2012: Combustible Interior Finish 78

79 D. Summary - BCBC Maintain Code with updates revisions and errata to stay abreast with Code changes as they occur. Province plans to issue updates annually December 20 of every year. 79

80 D. Summary - BCBC Use available resources in support of your interpretation of the Code. Request a formal interpretation of a disputed code item. BC Building Code Interpretation Committee interpretations not binding, may not be accepted by AHJ. 80

81 D. Summary - BCBC A previous BC Appeal Board decision which addresses your dispute will generally be accepted; Appeals are binding. Request a formal Appeal of code dispute with an AHJ 81

82 D. Summary - BCBC Accessibility to be provided to new construction as described in Subsection may be waived depending on size and occupancy. Accessible design criteria as described in Subsection Additional requirements found in Sentences (10) for doors and (12) for vestibules. 82

83 Questions? 83

84 Thank you Granville Street Vancouver, BC V6C 1T2 Phone Fax Web 84

Alternative Solution Approach to Fire Design

Alternative Solution Approach to Fire Design Alternative Solution Approach to Fire Design A Presentation for Cross-Laminated Timber Symposium and Workshop New Brunswick October, 2011 Presented by Andrew Harmsworth, M Eng, P Eng, CP Who Am I? Andrew

More information

Fire Considerations. Combustible Cladding and Components Of Exterior Walls and Curtain Walls. APEGBC/BCBEC Seminar, April

Fire Considerations. Combustible Cladding and Components Of Exterior Walls and Curtain Walls. APEGBC/BCBEC Seminar, April Fire Considerations Combustible Cladding and Components Of Exterior Walls and Curtain Walls APEGBC/BCBEC Seminar, April 21 2016 Andrew Harmsworth M Eng, P Eng, PE, CP Jun H. Kim, BASc, EIT Email: ah@ghl.ca/

More information

HOUSING CONVERSION Guidelines for the conversion of a house to commercial use.

HOUSING CONVERSION Guidelines for the conversion of a house to commercial use. PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT HOUSING CONVERSION Guidelines for the conversion of a house to commercial use. HAIR 105 January 2017 contents General Information 3 Zoning Information 4 Building

More information

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

WOOD USE IN NONCOMBUSTIBLE BUILDINGS INTRODUCTION The National Building Code of Canada (NBCC) 1 requires that some buildings be of noncombustible construction under its prescriptive requirements. Its use in certain types of buildings such

More information

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board. Schedule A Amendment to the Nova Scotia Building Code Regulations made by the Minister of Municipal Affairs under Section 4 of Chapter 46 of the Revised Statutes of Nova Scotia, 1989, the Building Code

More information

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS November 2018 Contents 1. Introduction... 1 2. Ontario Building Code and Second Dwelling Units... 1 3. How Do I Make My Secondary Dwelling Unit

More information

The Building Codes A.R.E. Building Design and Construction Exam Prep

The Building Codes A.R.E. Building Design and Construction Exam Prep Know Thy Codes! The Building Codes Building Codes The Code of Hammurabi 4000bc Developed 19 th and 20 th c. Codes define what you can and can t do Allowable area and height based on degree of danger Fire

More information

Annotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13

Annotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13 Annotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13 RED indicates new text. O. Reg. 368/13 comes into force on 1 January, 2015 DIVISION A PART 1 COMPLIANCE,

More information

DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS. Public Safety Services ADA-ABA COMMENT ASSISTANCE GUIDE

DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS. Public Safety Services ADA-ABA COMMENT ASSISTANCE GUIDE DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS BOBBY JINDAL GOVERNOR Public Safety Services H. BUTCH BROWNING STATE FIRE MARSHAL ADA-ABA COMMENT ASSISTANCE GUIDE The information submitted is not sufficient

More information

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date BUILDING AND SAFETY Tenant Improvement Checklist Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date APPLICATION The following items will be required at the permit counter before

More information

General Requirements for Mobile Homes

General Requirements for Mobile Homes Mobile homes shall conform in all respects to the CAN/CSA-Z240 MH Series of Standards and shall be complete structurally with the entire plumbing, electrical, and heating services installed. Prior to moving

More information

Bulletin BLD May 24, 2013 (Updated September 26, 2017) SECONDARY SUITES

Bulletin BLD May 24, 2013 (Updated September 26, 2017) SECONDARY SUITES Bulletin 2013-003-BLD May 24, 2013 (Updated September 26, 2017) SECONDARY SUITES The intent of this Bulletin is to advise homeowners, designers, and builders of the City s requirements regarding the development

More information

CHAPTER 6 TYPES OF CONSTRUCTION

CHAPTER 6 TYPES OF CONSTRUCTION CHAPTER 6 TYPES OF CONSTRUCTION SECTION 61 GENERAL 61.1 Scope. The provisions of this chapter shall control the classification of buildings as to type of construction. SECTION 62 CONSTRUCTION CLASSIFICATION

More information

NEWS LETTER MARCH 27, 2009

NEWS LETTER MARCH 27, 2009 PLANNING, BUILDING & DEVELOPMENT SERVICES DEPARTMENT 580-1 Street S.E. Medicine Hat, Alberta T1A 8E6 Telephone: 529-8374 FAX 502-8038 1 NEWS LETTER MARCH 27, 2009 GENERAL As you are probably aware there

More information

INTERNATIONAL CODE INTERPRETATIONS

INTERNATIONAL CODE INTERPRETATIONS 2012 INTERNATIONAL CODE INTERPRETATIONS PREFACE The 2012 International Codes promulgated by the International Code Council (ICC ) comprise a comprehensive set of model regulations for the construction

More information

WHO IS THIS COURSE FOR?

WHO IS THIS COURSE FOR? INTRODUCTION INSTRUCTIONS - READ ME FIRST BEFORE THE COURSE STARTS, WORK ON YOUR OWN AND COMPLETE ALL OF THE EXERCISES. If you come unprepared, you will have a difficult time to keep up with the pace of

More information

Applying the Building Code During Design

Applying the Building Code During Design Applying the Building Code During Design A Step-By-Step Process AIA Learning Units The Salt Lake City CSI Chapter is a Registered Provider with The American Institute of Architects Continuing Education

More information

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO EGRESS AZMIR SULTANA NICOLAS CHAMORRO MIMU SAKUMA EDWIN VEGA DEFINITIONS NC ACCESSIBLE MEANS OF EGRESS. A continuous and unobstructed way of egress travel from any accessible point in a building or facility

More information

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012 2012 Ontario Building Code Requirements for New Construction Bradford West Gwillimbury Building Division March 5, 2012 1 Ontario Building Code changes Applicable to permits applied for after December 31,

More information

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax:

City of Des Moines. Permit and Development Center 602 Robert D Ray Drive Des Moines, IA Phone: Fax: City of Des Moines Permit and Development Center 602 Robert D Ray Drive Des Moines, IA 50309 Phone: 515-283-4200 Fax: 515-283-4270 This Code Analysis Form must be completed and returned with the Building

More information

BUILDING CODE VARIANCE

BUILDING CODE VARIANCE BUILDING CODE VARIANCE April 2009 06-BCV-011-R1 Page 1 of 8 DISCUSSION MULTI-LEVEL STORAGE RACKING SYSTEMS The Alberta Building Code 2006 contains no specific requirements for multi-level storage racking

More information

PRESCRIPTIVE COMPLIANCE METHOD

PRESCRIPTIVE COMPLIANCE METHOD CHAPTER PRESCRIPTIVE COMPLIANCE METHOD 3 SECTION 301 GENERAL 301.2 Building materials. Building materials shall comply with the requirements of this section. 301.2.1 Existing materials. Materials already

More information

First Revision No NFPA [ Section No ]

First Revision No NFPA [ Section No ] National Fire Protection Association Report of 17 http://submittals.nfpa.org/terraviewweb/contentfetcher?commentpara... 10/21/2015 9:28 AM First Revision No. 4502-NFPA 101-2015 [ Section No. 3.3.92.4 ]

More information

Reference Guide: Mid-Rise Wood Construction in the Ontario Building Code Report by Morrison Hershfield (January 2015)

Reference Guide: Mid-Rise Wood Construction in the Ontario Building Code Report by Morrison Hershfield (January 2015) 2015 Reference Guide: Mid-Rise Wood Construction in the Ontario Building Code Report by Morrison Hershfield (January 2015) Ontario Wood WORKS! 60 Commerce Court P.O. Box 5001 Office W113 North Bay, ON

More information

OFFICE OF EDUCATIONAL FACILITIES FLORIDA BUILDING CODE SECTION 423 APPLICATION MATRIX

OFFICE OF EDUCATIONAL FACILITIES FLORIDA BUILDING CODE SECTION 423 APPLICATION MATRIX 423.1 Scope: Public educational facilities 423.2 Public schools and community colleges general requirements 423.2.1 Owner 423.2.2 Exemption from local requirements 423.2 Code enforcement 423.3.1 School

More information

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council Copyright This presentation is protected

More information

First Revision No NFPA [ Section No ]

First Revision No NFPA [ Section No ] National Fire Protection Association Report of 13 http://submittals.nfpa.org/terraviewweb/contentfetcher?commentpara... 10/28/2015 10:35 AM First Revision No. 5501-NFPA 5000-2015 [ Section No. 3.3.220.4

More information

2012 Code Update Training

2012 Code Update Training 2012 Code Update Training VIRGINIA RESIDENTIAL CODE Jack A. Proctor Virginia Building Code Academy Department of Housing and Community Development R202 Definitions BASEMENT R202 Definitions Story Above

More information

BUILDING CODE VARIANCE

BUILDING CODE VARIANCE BUILDING CODE VARIANCE December 2017 14-BCV-015 Page 1 of 6 MULTI-LEVEL STORAGE RACKING SYSTEMS PURPOSE The purpose of this variance is to allow for an alternative solution for multi-level storage racking

More information

International Code INTERPRETATIONS

International Code INTERPRETATIONS 2015 International Code INTERPRETATIONS 2015 International Code Interpretations First Printing: June 2016 ISBN#978-1-60983-666.5 Copyright 2016 by International Code Council ALL RIGHTS RESERVED. This 2015

More information

CODE ANALYSIS REPORT SECOND FLOOR

CODE ANALYSIS REPORT SECOND FLOOR CODE ANALYSIS REPORT SECOND FLOOR 384 DWIGHT STREET HOLYOKE, MA Prepared by Dietz & Company Architects, Inc. 17 Hampden Street Springfield, MA March 2014 INTRODUCTION The following report is a preliminary

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 02-35-890 Application No. 2002-22 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Articles 3.4.3.6. and

More information

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW 27 September 2007 prepared by: J. CHRIS EVANS ARCHITECT 3220 E. Terra Alta Blvd. No. 9 Tucson, Arizona 85716 520.319.8835 evansarch@hotmail.com

More information

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Construction requirements for LOWER LEVEL DEVELOPMENT in residential dwellings January 2018 contents GENERAL INFORMATION... 3 BUILDING CODE REQUIREMENTS...

More information

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS Florida Specific Amendment Code Reference NFPA 101 Open Parking Structure. A parking structure that, at each parking level, has wall openings open to the atmosphere, for an area of not less than 1.4 ft2

More information

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings John Buddy Showalter, PE VP, Technology Transfer American Wood Council Copyright This presentation is protected by US and International

More information

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and & &01 GENERAL To be developed. All of the exceptions have to be coordinated. &02 SPECIAL USE AND OCCUPANCY &02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections &02.1.1 and &02.1.2.

More information

Building Codes and Ordinances ARC 227

Building Codes and Ordinances ARC 227 Building Codes and Ordinances ARC 227 Week 6 Fire Resistive Construction 03.02.10 Instructor: Rick Staub, AIA Email: staub@pointonearchitects.com Phone: 860-434-7707 Fire Resistive Construction Passive

More information

INTERIOR ENVIRONMENT

INTERIOR ENVIRONMENT CHAPTER 12 INTERIOR ENVIRONMENT > SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter shall govern ventilation, temperature control, lighting, yards and courts, sound transmission, room dimensions,

More information

Washoe County PLAN SUBMITTAL

Washoe County PLAN SUBMITTAL Washoe County PLAN SUBMITTAL Commercial Tenant Improvement July 2016 Washoe County 1001 East Ninth Street PO Box 11130 Reno, NV 89520-0027 GUIDELINES The following is an outline of requirements for a Commercial

More information

TENANT IMPROVEMENTS GUIDE

TENANT IMPROVEMENTS GUIDE COMMUNITY DEVELOPMENT BUILDING DIVISION 4550 Walnut Lake Road West Bloomfield, MI 48325 (248) 451-4842 Phone (248) 451-4871 Facsimile (248) 451-4858 Inspection Line www.wbtwp.com TENANT IMPROVEMENTS GUIDE

More information

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council Copyright This presentation is protected

More information

CITY OF SASKATOON COUNCIL POLICY

CITY OF SASKATOON COUNCIL POLICY CITY OF SASKATOON COUNCIL POLICY NUMBER C09-029 POLICY TITLE The Plan Review and Building Inspection Program ORIGIN/AUTHORITY Item 6g) of Unfinished Business; Clause 12, Report No. 9-2010 of the Planning

More information

Possible Format for the layout of a DAC application. - Part M

Possible Format for the layout of a DAC application. - Part M Possible Format for the layout of a DAC application - Part M 2010 - This document should only be used with the clear understanding of the following: a. The aim of this document is to illustrate one possible

More information

Design and Construction AN ISO 9001:2008 CERTIFIED ORGANIZATION

Design and Construction AN ISO 9001:2008 CERTIFIED ORGANIZATION Design and Construction AN ISO 9001:2008 CERTIFIED ORGANIZATION Division of Design, 35 th Floor, Corning Tower The Governor Nelson A. Rockefeller Empire State Plaza Albany, New York 12242 Phone: (518)

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 02-38-893 Application No. 2002-33 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Clause 3.3.4.4.(1)(a)

More information

2010 National Building Code Adoption and Associated Process Changes

2010 National Building Code Adoption and Associated Process Changes Building Inspection City of Moncton 655 Main Street Moncton, NB E1C 1E8 Phone: (506) 856-4375 Fax: (506) 856-4348 Bulletin No. 14 From: Randy Richard Date: February 9, 2015 Subject: 2010 National Building

More information

2015 IBC Exit Systems

2015 IBC Exit Systems Objectives 2015 IBC Exit Systems Based on the 2015 International Building Code Upon completion, participants will be better able to: Determine those means of egress components that are defined as exits

More information

The Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks

The Lexington Division of Fire and Emergency Services. Fire Chief Robert G. Hendricks The Lexington Division of Fire and Emergency Services Fire Chief Robert G. Hendricks The Code of Hammurabi 229. If a builder builds a house for someone, and does not construct it properly, and the house

More information

Design Aid for Barrier-Free Accessibility in Existing Buildings

Design Aid for Barrier-Free Accessibility in Existing Buildings Design Aid for Barrier-Free Accessibility in Existing Buildings July 9, 2004 Table of Contents 1. Introduction 1 2. References 2 3. Access to the Building 2.1 Site Accessibility 2 4. Building Access 3.1

More information

Tenant Fit-Out for PLCB / Waynesboro Mall

Tenant Fit-Out for PLCB / Waynesboro Mall Tenant Fit-Out for PLCB / CODE REVIEW: PROJECT DESCRIPTION TENANT BUILD OUT PROPOSED USE SALE OF BEVERAGE ALCOHOL / PLCB SPRINKLERED: YES ALLOWABLE BUILDING HEIGHT & AREA: GROUP M / TYPE VB ALLOWED 1 STORY

More information

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:

More information

A minimum of 25% of any money spent upgrading areas of primary function shall be devoted to ADA upgrades. Existing non-compliant areas include:

A minimum of 25% of any money spent upgrading areas of primary function shall be devoted to ADA upgrades. Existing non-compliant areas include: October 23, 2012 PIX THEATER BUILDING CODE ANALYSIS 461 N 1 st St Woodburn, OR 97071 Executive Summary Since the most recent use in the building was a furniture store, the existing legal occupancy classification

More information

THE VIRGINIA HOUSING DEVELOPMENT AUTHORITY 2016 GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS. New & Rehab

THE VIRGINIA HOUSING DEVELOPMENT AUTHORITY 2016 GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS. New & Rehab THE VIRGINIA HOUSING DEVELOPMENT AUTHORITY 2016 GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS New & Rehab The Virginia Housing Development Authority (VHDA) recognizes the need to create

More information

2021 ICC Group A National Model Codes: Online Voting Guide

2021 ICC Group A National Model Codes: Online Voting Guide BACKGROUNDER NOVEMBER 2018 2021 ICC Group A National Model Codes: Online Voting Guide About NMHC Based in Washington, DC, the National Multifamily Housing Council (NMHC) is a national association representing

More information

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1

2015 IBC Update. Copyright 2014 International Code Council #1000PDF15 1 Goal 2015 IBC Update Based on the International Building Code (IBC ) The goal is to familiarize building officials, fire officials, plans examiners, inspectors, design professionals, contractors, and others

More information

INTERIOR FINISHES CHAPTER 8

INTERIOR FINISHES CHAPTER 8 CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials. 801.2 Interior wall and

More information

BUILDING CODE BULLETIN

BUILDING CODE BULLETIN BUILDING CODE BULLETIN September 2010 06-BCB-007 Page 1 of 5 VENTILATION AIR FOR DWELLING UNITS IN MULTI-UNIT RESIDENTIAL BUILDINGS DISCUSSION This STANDATA has been developed to cover alternative methods

More information

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) 2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:

More information

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION OFFICIAL USE ONLY Date: Permit #: Received by: For Staff Use Only: OFD ELEC Planning SITE LOCATION Site Address: Tax Parcel Number: TYPE OF WORK Building

More information

APPENDIX 3C DOMINION HOTEL SPECIFICATIONS

APPENDIX 3C DOMINION HOTEL SPECIFICATIONS APPENDIX 3C DOMINION HOTEL SPECIFICATIONS 1. GENERAL 1.1 Refer to Section 2.1 of Schedule 3 [Design and Construction Specifications] regarding compliance with Schedule 3 and this Building Specification.

More information

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and BCAC MOE Work Group Summary with Files Revised 11-20-2017 with meeting notes Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting ITEM Topic SECTION Notes

More information

SFS Form: 4 PROJECT NAME ADDRESS FIRE SAFETY ENGINEERING DESIGN REPORT. Date. 1.0 Introduction

SFS Form: 4 PROJECT NAME ADDRESS FIRE SAFETY ENGINEERING DESIGN REPORT. Date. 1.0 Introduction PROJECT NAME ADDRESS FIRE SAFETY ENGINEERING DESIGN REPORT Date 1.0 Introduction 1.01 This report describes the fire safety requirements and the provisions for this project. This fire safety report has

More information

Project: MOE FLS Reference Designs for Standard Classroom Upgrade 2-storey Nelson Block

Project: MOE FLS Reference Designs for Standard Classroom Upgrade 2-storey Nelson Block Project: MOE FLS Reference Designs for Standard Classroom Upgrade 2-storey Nelson Block Accessibility Report Reference: 246313 Prepared for: Ministry of Education Revision: D 2 September 2016 Document

More information

CONCEPT DESIGN BCA REPORT

CONCEPT DESIGN BCA REPORT CONCEPT DESIGN BCA REPORT CONCEPT DESIGN DOCUMENTATION PROPOSED ZUCCOLI PRIMARY SCHOOL 13/4/17 CONCEPT DESIGN Project: Zuccoli Primary School Location: Centre Road Zuccoli NT 0382 Prepared For: MKE Architects

More information

Municipal Code of Chicago CHAPTER EXIT REQUIREMENTS

Municipal Code of Chicago CHAPTER EXIT REQUIREMENTS Municipal Code of Chicago CHAPTER 13-160 EXIT REQUIREMENTS 13-160-010 General provisions. 13-160-020 Definitions. 13-160-030 Exit types - Requirements. 13-160-040 Exit types - Above or below grade. 13-160-050

More information

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018) PERMIT SUBMITTAL CHECKLIST: Signed and completed Building Permit application form. A separate Electrical permit is required from

More information

General Building Information

General Building Information Software Module s Description Page 1 General Building Information BUILDING AREA AND HEIGHT - This module designed to determine the height and area of buildings on the basis of occupancy group classification

More information

FRAMING INSPECTION GENERAL

FRAMING INSPECTION GENERAL FRAMING INSPECTION GENERAL 20 FRAMING INSPECTION GENERAL Tips Check habitable rooms for minimum light, ventilation and sanitation requirements. Check that stair framing meets headroom, width, and rise

More information

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

Updated references to SEI/ASCE 7 to the 2016 edition once it is available. Committee Input No. 8008-NFPA 5000-2015 [ Global Input ] Updated references to SEI/ASCE 7 to the 2016 edition once it is available. Submitter Information Verification Submitter Full Name: Tracy Vecchiarelli

More information

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL Permit Application #: Date: mm/dd/yy Project Address Applicant s Name NOTE TO PERMIT APPLICANTS: All permit applications must

More information

The Uniform Building and Accessibility Standards Regulations

The Uniform Building and Accessibility Standards Regulations UNIFORM BUILDING AND 1 The Uniform Building and Accessibility Standards Regulations being Chapter U-1.2 Reg 5 (effective April 10, 1992) as amended by Saskatchewan Regulations 102/92, 81/93, 35/94, 23/98

More information

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION 1 PLAN INFORMATION Residential plans must be legible and capable of digital scanning. All sheets shall be the same size and distinctly labeled with a sheet title and number. The minimum dimension of the

More information

Chapter 11. Dwelling Units and Sleeping Units

Chapter 11. Dwelling Units and Sleeping Units 1101 General Chapter 11. Dwelling Units and Sleeping Units 1101.1 Scoping. Dwelling units and sleeping units required by the scoping provisions adopted by the administrative authority to be Accessible

More information

BC BUILDING CODE ERRATA

BC BUILDING CODE ERRATA BC BUILDING CODE ERRATA The following changes should be made to print and offline copies of the 2012 BC Codes. The 2012 BC Codes subscription products include these changes. Highlighted text is used in

More information

APPLICATION FOR FINISHED BASEMENT PERMIT

APPLICATION FOR FINISHED BASEMENT PERMIT APPLICATION FOR FINISHED BASEMENT PERMIT REAL ESTATE TAX I.D. #: - - _ - _ 7607 W College Drive Ph: (708) 361-1804 Fax: (708) 923-7112 building@palosheights.org APPLICANTS: COMPLETE ALL ITEMS AND SUBMIT

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 02-04-859 Application No. 2001-81 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Sentences 3.2.3.7.(7)

More information

Company Overview. Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code)

Company Overview. Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code) Significant Code Changes Massachusetts State Building Code 9 th Edition (2015 International Code) Company Overview R.W. Sullivan Engineering (RWS) was established in 1945 and currently has 95 employees.

More information

Description Accessibility Standards. AODA OBC 2015 Ramps

Description Accessibility Standards. AODA OBC 2015 Ramps Ramps OBC Ammendments are related to the following accessibility standards: The ramp must have a minimum clear width of 900 mm. The ramp must have a clear height that provides a minimum Tactile Attention

More information

4. Number of drawings required: ( ) Locations of nearest streets

4. Number of drawings required: ( ) Locations of nearest streets CITY OF MANSFIELD BUREAU OF BUILDING AND CODES 30 NORTH DIAMOND STREET 3RD FLOOR MANSFIELD, OHIO 44902 Phone (419) 755-9688 Fax (419) 755-9453 www.ci.mansfield.oh.us COMMERCIAL BUILDING PLAN REQUIREMENTS

More information

CTC MEETING #25 CHILD WINDOW SAFETY REPORT

CTC MEETING #25 CHILD WINDOW SAFETY REPORT CTC MEETING #25 CHILD WINDOW SAFETY REPORT The Child Window Safety SG has not met following the 2012 Final Action Hearing. Group B activities did not necessitate SG meetings as the activity will be limited

More information

2012 INTERNATIONAL CODES SIGNIFICANT CHANGES

2012 INTERNATIONAL CODES SIGNIFICANT CHANGES 2012 INTERNATIONAL CODES SIGNIFICANT CHANGES TIM PATE CHIEF BUILDING OFFICIAL CITY AND COUNTY OF BROOMFIELD 2012 IRC 1. Section R302.1 has been modified to allow reduced fire separation distances when

More information

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION Town of Hague Building Inspector: Dale Wagner Home #: 306-225-2265 Cell #: 306-241-4741 Fill all part of the permit application including the date and signature.

More information

BRITISH COLUMBIA CERTIFIED PROFESSIONAL PROGRAM PRACTICE AND PROCEDURE MANUAL

BRITISH COLUMBIA CERTIFIED PROFESSIONAL PROGRAM PRACTICE AND PROCEDURE MANUAL BRITISH COLUMBIA CERTIFIED PROFESSIONAL PROGRAM PRACTICE AND PROCEDURE MANUAL Edition #1 August 3, 2015 Table of Contents List of Tables and Figures... 4 List of Attachments... 4 List of Abbreviations...

More information

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) Code Requirements for Existing Buildings R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com R.W. Sullivan Engineering (RWS) was established in 1945 and currently

More information

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT 7100 147 th Street West Telephone (952) 953-2588 Apple Valley, MN 55124-9016 Fax (952) 953-2515 www.cityofapplevalley.org INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT 1. Submit plan showing the proposed

More information

COMMERCIAL BUILDING PLAN REVIEW CHECKLIST

COMMERCIAL BUILDING PLAN REVIEW CHECKLIST Department of Urban Planning & Codes Enforcement City of Coatesville - 1 City Hall Place - Coatesville, Pennsylvania 19320 Phone: 610.384.0300 Fax: 610.384.6051 COMMERCIAL BUILDING PLAN REVIEW CHECKLIST

More information

635 BUREAU OF BUILDING CODES AND STANDARDS MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE

635 BUREAU OF BUILDING CODES AND STANDARDS MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE 16 DEPARTMENT OF PUBLIC SAFETY 635 BUREAU OF BUILDING CODES AND STANDARDS Chapter 3: MAINE UNIFORM BUILDING AND ENERGY CODE - COMMERCIAL BUILDING CODE OF MAINE SUMMARY: This chapter establishes the Commercial

More information

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace NOTABLE CODE REQUIREMENTS the following list represents important code requirements that shall be implemented into construction while still maintaining full compliance with all other requirements within

More information

Village of Glen Ellyn Basement Remodeling Project Guidelines

Village of Glen Ellyn Basement Remodeling Project Guidelines Village of Glen Ellyn Basement Remodeling Project Guidelines Existing unfinished basement space is often remodeled to create more habitable (living, sleeping, eating, dining) space in a home. Building

More information

2012 IBC Exit Systems

2012 IBC Exit Systems Accreditation Based on the 2012 International Building Code The International Code Council has been accredited as an Authorized Provider by the International Association for Continuing Education and Training

More information

LEAD DESIGN PROFESSIONAL:

LEAD DESIGN PROFESSIONAL: 2009 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project: Address:

More information

BUILDING CODE COMMISSION

BUILDING CODE COMMISSION Ruling No. 02-22-877 Application No. 2002-19 BUILDING CODE COMMISSION IN THE MATTER OF Subsection 24(1) of the Building Code Act, S.O. 1992, c. 23, as amended. AND IN THE MATTER OF Sentences 3.3.1.2.(3),

More information

INTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL

INTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials. 801.1.1 Interior finishes.

More information

Building Code Consultation Paper. Accessible Built Environment

Building Code Consultation Paper. Accessible Built Environment Building Code Consultation Paper Accessible Built Environment December 2012 March 2013 Contents Introduction... 1 About the consultation... 1 How to use this consultation paper... 2 About the Accessibility

More information

Building Code Consultation Paper. Accessible Built Environment

Building Code Consultation Paper. Accessible Built Environment Building Code Consultation Paper Accessible Built Environment December 2012 March 2013 Contents Introduction... 1 About the consultation... 1 How to use this consultation paper... 2 About the Accessibility

More information

INTERIOR FINISHES CHAPTER 8

INTERIOR FINISHES CHAPTER 8 CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL 801.1 Scope. Provisions of this chapter shall govern the use of materials used as interior finishes, trim and decorative materials. 801.2 Interior wall and

More information

ONTARIO REGULATION 350/06 BUILDING CODE

ONTARIO REGULATION 350/06 BUILDING CODE ONTARIO REGULATION 350/06 BUILDING CODE Consolidation Period: From August 12, 2010 http://www.e-laws.gov.on.ca/html/regs/english/elaws_regs_060350_e.htm Section 9.36. Cottages 9.36.1. Scope 9.36.1.1. Application

More information

SUPPLEMENTAL ACCESSIBILITY NO. 4 PLAN REVIEW CHECKLIST

SUPPLEMENTAL ACCESSIBILITY NO. 4 PLAN REVIEW CHECKLIST GEORGE CHAVEZ, City Building Official DAVID YELTON, Building Inspection Manager NESTOR OTAZU, Community Preservation Manager BUILDING & SAFETY DIVISION 455 North Rexford Drive, 1 st Floor Beverly Hills,

More information

Appendix 3G Wood First Matrix

Appendix 3G Wood First Matrix Appendix 3G Wood First Matrix Project Co will use wood in the Design of the Acute Care Facility in accordance with the following table, using wood where it is marked as subject to any comments set out

More information